Plans (7) BUP2020 -00204 OFFICE WPP RECEIVED TMARTIN0 � i 3082 7 SEP 0 S 2020 W.HANSON TENANTIMPROVEMENT CITY OFTIGARU SW 72ND AVENUE BUILDING DIVISIOPJ S,OREGON / �r� — - �--- F I;I � , forOF � f-L B D PACTRUST PROJECT #20420 n� J F II �� --- Tenant: BUILDING LOCATION � j A� j�� L._ +_0 s�Gc Jc� K ; P T/LAND/SCHMIDT ARCHITECTS a gooA �S �� �F E - -- PROJECT NARRATIVE Q N p ,l THIS PROJECT CONSISTS OF REMODEL WORK TO 2,852 SF OF EXISTING OFFICE SPACE. o WORK SHALL INCLUDE BUT NOT BE LIMITED TO O o • SELECTED DEMO OF EXISTING NON STRUCTURAL WALLS U H c • NON STRUCTURAL DRYWALL/METAL STUDS WALLS (� G • DOORS/FRAMES AND PAINTING = Q N M • LIGHTING • 0 0 \\ ALL WORK TO MEET ADA REQUIREMENTS. 0 p o LO W o 1121 C/) 0 (.0ti J O IY M co J � Q CD CD ci -' WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT FIRE PROTECTION SPRINKLERING _$ 1 LOCATION MAP TO TBC I & II / HEATING, VENTILATION & AIR CONDITIONING WORK m A-1 NOT TO SCALE - Z i ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE rn U c Q BUILDING INFORMATION OWNER: PACIFIC REALTY ASSOCIATES, L.P. 15350 SW SEQUOIA PKWY #300 PORTLAND, OR 97224 (503) 624-6300 (PHONE) (503) 624-7755 (FAX) AREA-QEVW( L, Room 3opb191 (BLDG. A) CONST. TYPE.: III-B THIS BUILDING HOUSES FOUR SEPARATE TENANTS INCLUDING THIS TENANT. THE EXISTING BUILDING IS A TWO STORY BUILDING OF 22,835 SF AND IS FULLY SPRINKLERED. THERE IS U FRONTAGE ON ALL FOUR SIDES OF AT LEAST 100 FEET. Ljj r ACTUAL BUILDING AREA TOTALS a U - K I B OCCUPANCY = 22,835 SF 12-0Q MIXED OCCUPANCY - NON-SEPARATED USES. (OSSC 508.3.2) F- 0 ALLOWABLE AREA z ° co= � B 19,000 + (200% INCREASE FOR FIRE SPRINKLERS) = 33,250 SF U U) v U) Uj N z < ti 22,835 SF < 33,250 SF -NON-SEPARATED OCCUPANCY IS ALLOWED (508.3.2) Q CO a x D N ID TENANT INFORMATION OFFICE c®Pv z co � TENANT: TILAND/SCHMIDT ARCHITECTS CITY of TTGART?_, Q X � � REVIEWED POR CODE COMPLIANCE U o 0 ° OCCUPANCY AREAS & LOADS: Approved:'-['/ } } } B 2,332 SF USABLE 16 OCC oTQ DATE: 9/4/20 2,852 SF RENTABLE Permit #: - on ZOLI PERMIT / CONST Address: suite #: REVISION NUMBER OF EXITS REQUIRED Br Date: 9:im � B 1 EXIT 1 2. - CODE SUMMARY 3. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH STATE AND LOCAL CODE 4. REQUIREMENTS THAT APPLY, INCLUDING BUT NOT LIMITED TO: 5. • 2019 OREGON STRUCTURAL SPECIALTY CODE (OSSC) 6. • 2019 OREGON MECHANICAL SPECIALTY CODE (GMSC) VALIDITY OF PER"dl T 7. 2 FIRST FLOOR PLAN_ _ Z� 2017 OREGON PLUMBING SPECIALTY CODE (OPSC) THE SSUABASED ON CEOFCONSTRucRMI 8. A-1 1/16° = 1'-0" . 2017 OREGON ELECTRICAL SPECIALTY CODE (OESC) DOCUMENTS AND OTHER • OFC DATA SHALL NOT PHEVENT DRAWN BY: 2019 OREGON FIRE CODE (OFC) THE CODE OFFICIAL FROM R.M.T. • ASCE-7-10 REQUIRING THE CORRECTION • ICC/ANSI A117.1-2017 OF ERRORS. OSSC 105.4 • 2019 OREGON ENERGY EFFICIENCY SPECIALTY CODE CITY OF TIGARD Approved b Planning Date: 2-l Initials: 01 00 00 GENERAL DATA 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 3. LIST TONNAGE OF EACH UNIT. GENERAL REQUIREMENTS PSI)G80. HVAC-DESIGN PROCEDURE JcvJ_ ,J - 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR 1. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND AN APPROVED EQUAL. 1. USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.AC.SYSTEM PER DESIGN STANDARDS NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. LISTED BELOW. 5. STANDARD GYPSUM BOARD SHALL BE TYPE')',5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM #3082 2. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING C36 2. PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH WMARTIN W.HANSON CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE 6. TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 7. USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH INCLUDE THE FOLLOWING: 3. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE SYSTEM. a. DUCTING AND SIZES CLA KAM S,OREGON EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK WALL CONSTRUCTION EXECUTION b. SUPPLY AND RETURN LOCATIONS AND CFM AT EACH GRILL OR DIFUSER DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TOALL ION LEFT INTERIALS THE TENANT(NSTALLATION,DISPOSAL OF EXCESS SPACE AS NOTED ON PLANS),CLEANING AND(ALS ALL PREPARATION OF SUBSTRLE FINISH ATE HALL BE 1. FASTEN FRAMING SCREWS. WELDING SHALL CONFORM TO S D WELDINGS TOGETHER BY WELLDING PRO EDURE. ELLLING OR SELF-TAPPINGECTRODES RODES AND SCREW ROOF EQUIPMENT,SIZES AND LOCATIONS G SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD f �;cliff I it �ERI�OSQTAIT LOCATIONS AND ZONE/UNIT ING DUCTED SMOKE TASSOCIATED THEREWITH OF O� MATERIALS LIGHTER THAN 18 GA. I 4. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS �+ �y �f INTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. '9,' ZONE DIAGRAM PROJECT #20420 5. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION HVAC DESIGN STANDARDS B. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK MATS"TO PROTECT EXISTING STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: CARPETS. LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE 7. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF AND JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE 1. 350 SQUARE FOOT PER TON(UNLESS OTHERWISE APPROVED IN WRITING BY PACTRUST). ROOF MEMBRANE TO MATCH THE EXISTING ROOF. STUDS AT CORNERS, POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE,AS WELL AS CRITERIA PROVIDED TO PACTRUST.BY 4-1 8. ALL ROOF WORK TO BE COORDINATED WITH PACTRUST PROPERTY MANAGEMENT AND BE PERFORMED BY AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE RACKS.PROVIDE LONG LEG TENANT PRIOR TO CONSTRUCTION: - TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE. PACTRUST APPROVED ROOFING COMPANIES. APPROVED COMPANIES INCLUDE: a. EXTERIOR EXPOSURE AREAS a. ARROW ROOFING, 503-080-2767 4. REMOVE EXISTING FLOORING AT NEW WALLS UNLESS SPECIFICALLY INDICATED BY ARCHITECT. b. INTERIOR AREAS,SIZE AND USE }�.0 b. ROOF TOPPERS,360-574-7246 5. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR c. CONFERENCE/TRAINING ROOMS " THE PROJECT. c. GOT YOU COVERED ROOFING,503-975-9136 d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION r , 6. AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING, INSTALL THE GYPSUM BOARD(OR AUQATOUGH) AND 24-HOUR USE.VERIFY NEED FOR A SEPARATE SPLIT SYSTEM TO MAINTAIN TEMPERATURE. LL) 1O.CONTRACTOR MAY SUBMIT ALTERNATE ROOFING CONTRACTOR TO BE REVIEWED AND APPROVED BY WITH 1/4"GAP BETWEEN THE BOARD AND THE FLOOR TO PREVENT WICKING. PACTRUST PRIOR TO BID. 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. 7. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. 11.VERIFY WITH BUILDING OWNER ANY ROOF WARRANTY REQUIREMENTS. 8. FINISH QUALITY: VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE 12.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. AREA PROCESS TRADE NOMENCLATURE ZONES. 13.ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH OFFICE/OTHER AREAS TAPE/2 FINISH COATS•/ SMOOTH FINISH TAPED(LEVEL 4) 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH WLKEM 921 USG"FIRST COAT •SAND AFTER TAPE/FINISH COAT 5. UNITS: LENNOX,TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 7 1/2 CD POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. (S) TONS SHALL HAVE SPECIAL WRITTEN APPROVAL FROM PACTRUST. O co 14.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS NOTE:AT EXTREMELY DARK ACCENT WALLS PROVIDE LEVEL 5 FINISH. AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. 9. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS 6. HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE CONNECTED SHOWN ON PLANS. TO A MONITORING STATION WITHIN THE BUILDING. C 15.PROVIOE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO7. ECONOMIZER TO MEET CODE AND AS FOLLOWS: COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL 09 53 00 SUSPENDED ACOUSTICAL CEILING BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. = a N ACTIVITIES. 1. COMPLY WITH CURRENT SEISMIC REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. b. BAROMETRIC RELIEF ON 5-7 112 TON UNITS. Q 16.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING 2. FOLLOW MANUFACTURERS PRINTED INSTRUCTIONS FOR THE DELIVERY AND INSTALLATION OF CEILING C. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. O RESTROOM FACILITIES. SYSTEM,INCLUDING GRID,PANELS,AND HANGARS AND ACCESSORIES. - 3. USE ALL PRODUCTS FROM ARMSTRONG WORLD INDUSTRIES,INC. d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. 17.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT B. ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. W 0 O Lo PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER 4. CO-ORDINATE CEILING WORK WITH INSTALLERS OF RELATED WORK INCLUDING BUT NOT LIMITED TO COMMON BUILDING AREA BE USED FOR STORAGE. INSULATION,GYPSUM BOARD,LIGHT FIXTURES,MECHANICAL SYSTEMS,ELECTRICAL SYSTEMS AND FIRE 9. DROP CANS TO BE SAME SIZE AS CURB OPENING AND TO EXTENDED TO WITHIN 2'OF SUSPENDED CEIILING. C co I` 18.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. SPRINKLERS. MINIMUM 26 GAUGE FOR SUPPLY AIR. SEAL EDGES OF SUPPLY AIR. Z ' V V 5. REPLACE EXISTING CEILING TILE WITH ARMSTRONG FISSURED#705,24 x 24 x 5/8"W/ANGLED TEGULAR EDGE %DISTRIBUTION DUCTWORK: O < 19.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, � J � � ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 6. ALL TILE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES. CUT/TRIM TILE EDGE TO CREATE TEGULAR EDGE a. SPIRAL DUCT PERMITTED ONLY IF EXPOSED. 20.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. CONDITION SO THAT CEILING TILES LAY FLAT. MLr) m co b. 26 GAUGE OR TO SMACNA STANDARDS WHERE DUCT IS CONCEALED ABOVE A CEILING. 0 CD CD 21.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. 7. TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL OVER THE ENTIRE SPACE. c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH d L Lr) 22.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. 8. BENT OR DAMAGED T-BARS TO BE REPLACED. MINIMUM R4.2 INSULATION WITH FSK BARRIER. 23.CLEAN ALL SUPPLY AND RETURN DIFFUSERS AT PROJECT COMPLETION. 9. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES4"EXPANSION SLEEVE d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD 24.UPON COMPLETION OF THE PROJECT,THE CONTRACTOR MUST PROVIDE A DETAILED CLOSEOUT PACKAGE ACCEPTABLE. HANGERS AND FULL DIAMETER STRAP UP TO 18'0. LARGER THAN 18'MUST HAVE SADDLE TYPE CLAMP. Q PER INSTRUCTIONS INCLUDED IN THE CONSTRUCTION CONTRACT.RETENTION WILL BE HELP PER CONTRACT 09 62 00 SPECIALTY FLOORING e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 pl UNTIL THE COMPLETED CLOSEOUT PACKAGE IS RECEIVED AND HAS BEEN APPROVE BY THE CONSTRUCTION 09 65 19 RESILIENT FLOORING-LUXURY VINYL TILE DEGREES. MANAGER,ARCHITECT,AND PROPERTY MANAGER. I. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. m 25.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, 1. FINISH FLOORING TO EXTEND UNDER CASEWORK. FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED 2. INSTALL TILES IN 113 OFFSET ASHLAR PATTERN U.N.O. g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF 3. DO NOT WAX OR OTHERWISE SURFACE TREAT EXCEPT CLEANING. 11.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. WHETHER OR NOT SHOWN ON THE DRAWINGS. 4. USE SCHLUTER TRANSITIONS PER FLOORING TRANSITION DETAILS. 12.DIFFUSERS: 26.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.0". a. SUSPENDED CEILING SYSTEM BAR PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN CI- 09 68 00 CARPET R ) 27."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME 1. BROADLOOM TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. b. GYPSUM BOARD CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE- 28-.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. --- 2. CARPET SQUARE(24"X 24'NOMINAL)-__ _ __. - DESIGN TITUS350;EXHAUST.METALOR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN TITUS 50F. 29.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN a. INSTALL IN VERTICAL ASHLAR PATTERN U.N.O. c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED INDUCT AT OR NEAR CLOSEST TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO 3. CARPET PLANK(12"X 36"OR 18"X 36") WYE BRANCH. REPLACEMENT AT CONTRACTOR COST.AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL a. INSTALL IN RANDUM ASHLAR PATTERN U.N.O. d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE COMPLETION. CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS 4. USE SCHLUTER TRANSITIONS PER FLOOR TRANSITION DETAILS. DIRECTED AT CONTRACTOR'S COST. 09 9123 PAINTING 13.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE 30.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND HONEYWELL COMMERCIAL GRADE V/SIONPRO 8000 TOUCH SCREEN MODEL TB8220U1003 WHERE POSSIBLE. INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT MINIMUM OF TWO COPIES OF ALL INTERIOR: _ APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO.P374.2800 -7 DAY PLUMBING SYSTEMS SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD. ARCHITECT WILL RETAIN ONE 1. WALLS: PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY COPY AND ONE COPY WILL BE AND TO THE CONTRACTOR.SUBMITTALS MAY BE DELIVERED IN PDF REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM FORMAT FOR REVIEW. a. PRIME NEW DRYWALL WITH MILLER PAINT HIGH-BUILD"SUPER SEAL"PRIMER. THERMOSTATS AND BALANCE SYSTEM. 31.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT 14.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER 1204-XX WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER PAINT 170.5-XX SIG 15.HVAC TESTING. LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE LATEX ENAMEL. INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE 2. DOORS AND FRAMES: a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, CENTERED IN CEILING TILE OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH ( a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH 7W0 COATS OF SEMI-GLOSS OIL.SPRAY OR APPROVED PLANS AND SPECIFICATIONS. APPLICABLE). LOCATION OF THOSE . THE ARCHITECT PRIOR TO INSTALLATION. GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY ROLLED APPLICATION.SUBMITTALS MAY BE DELIVERED IN PDF FORMAT FOR REVIEW. b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. 32.000RDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH ONDO,SAND AND PRIME PATCHES WITH INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL.SPRAY OR ROLLED APPLICATION c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND V J c. WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH PAINTER'S FILED WITH PACTRUST. 08 10 00 DOORS AND WINDOWS PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX CAULK, 1. RE-USE EXISTING DOORS,HARDWARE,AND FRAMES WHERE POSSIBLE. AND FINISH WITH SATIN OIL ENAMEL. 16.Pa. AutoCAD CLOSE OUT DOCUMENTS REQUIRED: r , a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. 'u J' 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: d. WOOD-STAIN,SEAL AS REQUIRED,AND VARNISH WITH SATIN VARNISH, b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. W a. BAXTER AND FLAMING. (503)225-0486 3. CEILINGS: c. HARD COPY OF AutoCAD FILE ABOVE. b. D&D DOOR (503)205-5533 a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING TSTATS. c. BENSON INDUSTRIES (503)907-2200 ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT 6200 OR 4480. u b. NEW GYP BOARD/PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. d. GRANT SUPPLY (360)887-0647 WITH MILLER PAINT 6200 OR 4480. 26 00 00 ELECTRICAL: DESIGN/BUILD 3. DOOR AND RELITE FRAMES SHALL BE WESTERN INTEGRATED MATERIALS(WIM),OR APPROVED. SUBMITTAL 4. GENERAL NOTES: GENERAL REQUIRED PRIOR TO ORDERING MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. 4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER 1. ALL ELECTRICAL FEEDS TO OUTLETS,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. SPRAY. HORIZONTAL RUNS UNDER WINDOWS AND RECEPTACLES ON THE SAME STUD. - 5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING 8. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. RAGS AT THE END OF EACH DAY. 3. ALL NEW ELECTRICAL DEVICES TO BE WHITE.NYLON COVER PLATES NOT ALLOWED. 7. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5"BACKSET. d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING 4• REPLACE ALL NON-WHITE EXISTING ELECTRICAL DEVICES TO WHITE.NYLON COVER PLATES NOT ALLOWED. Q 8. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. Lll HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH e. PROTECT WORK OF OTHER TRADES. 5. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT 6. PROVIDE TYPEWRITTEN UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. Z SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS f. PROVIDE"WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. Lu U) PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL 7. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN ON PLAN EQUAL TO co SAMPLE. 10 00 00 SPECIALTIES 1-FOOT CANDLE. = U ) 10 28 13 BREAK COUNTER 8. EXIT LIGHTS:LITHONIA EDGR-G-EL RECESSED MOUNT,GREEN LETTERS.(CLASS A BUILDINGS - U1 � 9. ALL INTERIOR GLAZING SHALL BE TEMPERED. 10.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHEN/BREAK ROOM)BOBRICK B-262 9. FOR FLOOR POWER AND DATA ACCESS. �U W � FINISH FOR AS NEW LOOK. 1044 16 FIRE EXTINGUISHERS a. AT RAISED SLABS:USE WIREMOLD RC7 FLUSH POKE-THRU SERIES OR EQUAL. c/J Z Q Q) 11.TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK. 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) b. AT SLAB ON GRADE:USE WIREMOLD RFB4E BOX WITH 6CTC2 COVER AT CONFERENCE ROOMS 09 00 00 FINISHES 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. AND 6CFFTC COVER AT FURNITURE FEEDS.PROVIDE 1"CONDUIT FOR POWER AND 2'CONDUIT FOR Qm N 0 DATA. GENERAL 12 00 00 FURNISHINGS z F n 0 8. LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA)BY FUTURE TENANT. U) Z 1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. TO INSTALLATION OF NEW FLOORING. 9. LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. Q Q 2. INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. J 2. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS.EXCLUDES LVT AND 10.LOCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. J CD CC SOME VCT APPLICATIONS.VERIFY WITH ARCHITECT PRIOR TO APPLYING WAX COATINGS. 2100 00 FIRE SUPPRESSION : DESIGN/BUILD 11.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT U O, 3. EXISTING VCT TO REMAIN TO BE STRIPPED AND APPLY NEW WAX COATING. 1. ADJUST EXISTING SPRINKLERS THROUGHOUT SPACE AS REQUIRED BY CODE. SPRINKLER HEADS SHALL BE AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND ` Q (p 0 CENTERED IN 2 X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL HARD SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE 1 a r- D_ 4. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: CEILING AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. a. FLOOR COVERINGS,BASE AND TRANSITION STRIPS INSTALLATION. 12.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA DATE: 9/4/20 b. PLASTIC LAMINATES 2. IN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC MOVEMENT. BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO FINISH SPECIFICATIONS. PERMIT / CONST c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) NO OOPS RINGS ALLOWED. 13.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE 22 00 00 PLUMBING : DESIGN /BUILD DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION d. PAINT GENERAL REQUIREMENTS OF THE EXISTING LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING. REVISION e. TILE,MARBLE,GRANITE,STONE,GROUT AND SCHLUTER TRIMS OFFICE LIGHTING f. TOILET PARTITIONS 1. CONTRACTOR TO SUBMIT LAYOUT ON ELEVATIONS AND PLANS PROVIDED FOR ALL SHUT OFF VALVES,CLEAN OUTS,ACCESS DOORS,AND FLOOR DRAINS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 1 OFFICE LIGHT FIXTURES: LITHONIA LED FIXTURE.2BLT2 40L ADP MVOLT GZ10 LP835.ALL FIXTURES TO BE 3. FINISH FLOORING TO EXTEND UNDER ALL NEW CASEWORK. 2. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUT OFF VALVE FOR EACH SET OF EQUIPPED WITH DIMMING. 4. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET PER TRANSITION RESROOMS. LOCATE VALVE BEHIND HANDICAP WATER CLOSET IN MEN'S TOILET ROOM. 2. RECESSED LED DOWN LIGHT: LITHONIA LDN6 35/10 L06 AR LD MVOLT TRW(IP55 LENS) STRIP DETAILS. 3. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS. ALL EXPOSED PIPING TO BE 3. OFFICE EGRESS LIGHTING:ISOLITE MINI GENIE SERIES LED VERSION LMIGN NM SQ-CEILING AND WALL 2. 5. PROVIDE SCHLUTER METAL TRIM AT ALL EXPOSED EDGES OF TILE(EXCEPT AT BULLNOSED EDGE) INSULATED. MOUNT. SEE PLAN FOR EGRESS PATH.USE OF ISOLITE INVERTER AS ALTERNATE TO BATTERY IS 3 4. WATER HEATER(ELECTRIC)30 GAL AND LARGER 277V LESS THAN 30 GAL 120V. PROVIDE HUB DRAIN AT ACCEPTABLE. 09 21 00 GYPSUM BOARD LOCATION FOR BLOW OFF. 4. LIGHT SWITCHES:ACUITY CONTROLS PRE SET ALL PRIVATE OFFICE AND CONFERENCE ROOM SWITCHES TO GENERAL 'VACANCY"AND TO TURN�N AT�T DIM LEVEL.SET TIME-OUT TO MAXIMUM. 4' 1. ALL GYPSUM BOARD WALLS: ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHT ANGLES OR 5. POINT OF DEMAND WATER HEATER-BOSCH POWER STREAM PRO-MODEL RP2P 277V/30A. ADJUST WATER a. STANDARD WALL SWITCH WITH OCCUPANCY SENSOR-USE WSD PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN WITH 1"TYPES FLOW SETTING TO PROVIDE A HEATING RANGE OF 105 TO 120 DEGREES. J. DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS AND 6. FLOOR DRAINS SHALL BE INSTALLED IN TOILET ROOMS CONTAINING 2 OR MORE WATER CLOSETS OR 2 OR b. WALL SWITCH WITH OCCUPANCY SENSOR AND DIMMING-USE WSXD INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING), MORE WATER CLOSETS AND URINALS IN COMBINATION. THE FLOOR SHALL SLOPE TOWARD THE FLOOR c. WALL SWITCH WITH DIMMING AND CEILING MOUNTED OCCUPANCY SENSOR-USE SPOD 6• EACH SIDE AND OPPOSITE SIDES. DRAIN. 28 30 00 ELECTRONIC DETECTION AND ALARM 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN 7. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. NO ATMOSPHERIC 7 FINISH COATS(LEVEL 4 FINISH). PAINT AS INDICATED. PRIMERS. DRAINS TO BE PRIMED FROM TOILET FIXTURES UNLESS OTHERWISE APPROVED BY GENERAL _ 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH PACTRUST. PROVIDE A MIN. 12"x 12"ACCESS DOOR. 1. FOR HORN/STROBE DEVICES USE"SYSTEM SENSOR"SPECTRALERT ADVANCE DEVICES,OR APPROVED 8• COAT(LEVEL 3 FINISH). PAINT AS INDICATED. PLUMBING-BREAK ROOM FIXTURES EQUAL. 4. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER 1. BREAK ROOM SINK ELKAY ELUHAD211555(UNDER COUNTER MOUNT). METAL STUDS. 2. KITCHEN FAUCET-AMERICAN STANDARD COLONY SOFT SINGLE CONTROL FAUCET#4175.500. DRAWN BY: 5. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT.QUIETJOINT SHH WHERE WALL 3. 1/4"COPPER WATER LINE W/SHUT OFF VALVE FOR COFFEE MAKER AND REFRIGERATOR,SEPARATE LINES IF R.M.T. MEETS MULLION AND EMSEAL WHERE WALL MEETS GLAZING.COLOR SELECTED BY ARCHITECT. REQUIRED. 6. AT ALL EXISTING WALLS, REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND 2300 00 HVAC : DESIGN / BUILD PATCH HOLES READY FOR PAINT. 7. REPAIR GYPSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR GAS METER PAINT. 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. 8. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO TENANTS MOVE-IN. WALL CONSTRUCTION MATERIALS HVAC-BID PROCEDURE 1. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN INSTALLATION. PROPER WORKING ORDER. 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED ON PLANS WHERE PHYSICALA� 2 2, INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH - STRUCTURAL PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED UNIT LIVE LOADS. DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. 3 1 2 3 FINISH MATERIALS 1 � ^ ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. ;_LS�j�MARTIN ��CARPET SQUARE TILE: � #3082 � CPT-1 MOHAWK GROUP PTR-CARPET SQUARE"ART EXPOSURE"ADAPTALBE BT432/06432 W.HANSON 853 FALLOW, FLEXLOK CONNECTORS, BRICK ASHLAR INSTALLATION(NOTE: FOR PRICING OF ALL MOHAWK PRODUCTS CONTACT: CLA KAM S,OREGONBETH GISH (503)704-4166 or STEPHEN DELONG (971)201-0458 � ^ II , I a LUXURY VINYL TILE V qqs 1 E ; �f Ii1 i � ' Ii pl ( LVT MOHAWK GROUP SELECT STEP STONE C0007 �F OF T012M LIGHT MOCHA 18 X 36 EPIT Ip BASE RF FLEXCO 4"FLAT RUBBER BASE, 071 BLACK/BROWN,AT ALL CARPET AREAS. PROJECT #20420 RC FLEX 4"COVE RUBBER BASE,071 BLACK/BROWN,AT ALL HARD SURFACES. PAINT: PT-1 MILLER 110-4-10 ACRO PURE ULTRA-LOW VOC (COLOR T.B.D.), SATIN LATEX. PT-2 MILLER 110-4-10 ACRO PURE ULTRA-LOW VOC (COLOR T.B.D.), SATIN LATEX(ACCENT COLOR) 4_4 (FOR DARK ACCENT COLORS US MILLER EVOLUTION MATT PAINT) U (AT ALL RESTROOMS USE MILLER 320-5-10 SEMIGLOSS ACRINAMEL) ^' OPEN OFFICE 4J OFFICE ,os LAMINATE: 4_0 106 PL-1 FORMICA 5881-58 CHOCOLATE WARP ALL FACES CAB PULLS POLISHED BRASS L U COUNTERTOP: L SOLID SURFACE COUNTERS a OFFICE SSC RENTAL QUARTZ BQ300P ALPINE POLISHED COUNTER, B.S.AND SELF-EDGE OO . DED U) M SERVER RACK PRINT ROOM c ,04 NEW LLIFOR TENANTI'll'l Y WALL FOrtS.TENANT- d TO PROVIDE N CHANGE TO DED EQUIPMENT Q r\ JQ SPECIFICATIONS O a) FOR TENANT COPIER ---� - OPE OFFICE RE-LAMINATE BASE AND 45' 45" I4 -RE LU O l L__J 101 UPPER CABINETS.INSTALL 65-MICRO. L (O ti SOLID SURFACE COUNTER BREAK Z I TOP/BACKSPLASH AND 4 UNDERMOUNTSINK ,03 - � J c 0 11 4Ea E CARPET DIRECTION _ _ _ CC� M 0 0 - - - G a J to l RETAIN DOOR AND RELOCATE DOOR I - Q --SIDELITE.SEE 3/AJ �.�-moi' ♦ AND SIDELITE •1 ��'' �� iI �� W` --- r-0• RECEPTION O DD T La m CO FERENCE I Ir..- Llj tc; II r-o• �I I Ax, AXX ANAn I I V DEMO PLAN z� 3 PARTITION AND POWER PLAN z� 5 FLOOR FINISH LAYOUT Z� A-3 SCALE 1/8" = 1'-0" A-3 SCALE 1/8" = V-0" A-3 SCALE 1/4" = 1'-0" 2 , 3 1 2 3 N U) Fam Lu — , /I TZ Av A At — UJI LU Lo U co civ Acn i , ---- I U W w N A n Cn ZQCD • 0 coz mZ0 C4 Z " A V n A N/ ❑ - ❑ PERMIT PERMIT/4/20 /CONST v �o� asp REVISION m CONSTRUCTION LEGEND �111 21P Fv o EXISTING TO REMAIN n -- -� _ ------ 2. -- - -------- EXISTING TO BE REMOVED NEW STANDARD WALL WITH INS. 3 • 4. too - DUPLEX RECEPTACLE e ELECTRICAL PANEL 5. i�� i�� i�� -• I i�� ' 0 49) FOURPLEX RECEPTACLE O POWER J-BOX 6 DEDICATED OUTLET ® FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA 7 _ V EXISTING ELECTRICAL TO REMAIN ® FIRE EXTINGUISHER IN RECESSED CAB. 8. U ® FLOOR MONUMENT W/SERVICES SHOWN FIRE EXTINGUISHER-SURFACE MOUNTED SPECIAL OUTLET OT THERMOSTAT DRAWN BY: 2 CEILING DEMO PLAN Z (!)REFLECTED CEILING PLANZ TELIDATA MUD RING WITH PULL STRING R.M.T. A-3 SCALE 1/8" = 1'-0" A-3 SCALE 1/8" = 1'-O° � e 2 X 2 LED BLT CEILING FIXTURE ® SUPPLY DIFFUSER RETURN DUCT TENANT SPECIALTY FIXTURE(T.B.D.) ® EXHAUST FAN RECESSED COMPACT FLUORESCENT LIGHT(TYP.) TILE�PRINKLER HEAD — $ STANDARD SWITCH e EXIT SIGN (LED RED) ® OCCUPANCY SWITCH (per HORN/STROBE FIRE ALARM(WALL MOUNT) ( CEILING OCCUPANCY SENSOR Q, ,p HORN/STROBE FIRE ALARM(CEILING MOUNT) DETAIL GENERAL NOTES: FCLA 1. FOR WALLS UP TO 14'-0"TALL, USE 3625125-30 MTL. STUDS @24"O.C. UNLESSCALLED OUT OTHERWISE IN DETAIL. USE 362T1 --30 MTL. TRACK.2. FOR WALLS OVER 14'-0"TALL, USE 6005125-33 MTL. STUDS @ 16"O.C. UNLESS SCHLurER ANONCALLED OUT OTHERWISE IN DETAIL. USE 6007125-33 MTL. TRACK. SCHIENE AE3o3. ALL WALLS:ATTACH BOTTOM TRACK TO FLOOR WITH POWDER DRIVEN OREGONANCHORS AT 24"O.C. CPT LVi 4. IN WALLS WITH ACOUSTIC INSULATION, SET BOTTOM TRACK IN BED OF SEALANT. ROOR BEAM CARPET TO LVT DETAIL r' �& OF 5. FOR WALL FINISHES, FLOOR FINISHES AND WALL BASE TYPE, REFER TO PROJECT FINISH SCHEDULE. RACO STYLE POWDER DRIVEN ANCHORS RECESSED REVEAL #20420 WALLS#1-487RDT SUSPENDED CLG ASSEMBLY STRUCTURAL SUPPORTING CALCS: 1. POWERS 0.300 HEAD (3/4" EMBED)0.145 SHANK DIAMETER ALLOWABLE SHEAR=70 LBS �45° V 2. 12'-0"TALL WALL WITH CODE REQUIRED 5 PSF MINIMUM LATERAL "' �.`.'C•<•.r':' °_•>�t•^"-"'•"' •' ''"` (WIND) LOAD SHEAR=5 PSF - 12'-0"/2=30 PLF -0 3. ANCHORS AT 16"O/C 20 GA 3 5/8" METAL STUD BRACING TO ROOF STRUCTURE AT 10'-0" SHEAR=30 PLF ' 16"/ 12"=40 LBS OC W/(2)#8 SHEET METAL (� 4. UNITY CHECK SCREWS AT EACH END. BRACING L- 40 40 LBS/70 LBS =0.57< 1.0 OK TO BE PROVIDED WHERE DISTANCE Q 5. ANCHORS AT 24"O/C BETWEEN PERPENDICULAR INTERSECTING SHEAR=30 PLF'24"/ 12"=60 LBS WALLS OR HORIZONTAL BRACING BETWEEN WALLS EXCEEDS 12'-0"OC 6. UNITY CHECK — ' O 60 lbs/70 lbs= 0.86 < 1.0 OK m 1 GENERAL NOTES WALL BRACING DETAIL 9 FLOORING TRANSITIONS c A-4 SCALE 1" = 1'-0" A-4 SCALE 3" = 1'-0" A-4 SCALE 1" = 1" Orn 20 GA 3 5/8" METAL STUD BRACING TO ROOF Z) O' STRUCTURE AT 10'-0" OC TO BUILDING STRUCTURE W O 0O Lo 2'-0" 2'-0" ABOVE FOR WALLS LONGER THAN 12'-0"WITHOUT 0 � r- INTERSECTION WALLS. FASTEN EACH END WITH Z 4 4 (1)#8 SHEET METAL SCREW '� U g N N cio CD TYPICAL STUD SOUND INSULATION 4'CENTERED Lo X M co OVER WALL LnLO LD SUSPENDED CEILING RACO STYLE RECESSED REVEAL HEADER. Q CONCEPT WALLS#1-487RDT TYPICAL TRACK MTL. STUDS. o INSTALL STUDS WITH 5/8"GYP. BRD. BOTH SIDES SAME DIMENSION (10" F MIN.) FOR BRIDGING p� Z = ALIGNMENT CL w CENTER LINE OF STUD m x a w Of O ____ � - -- 3-1/2" BATT INSUL. IN SOUND ATTENUATION WALLS POWDER DRIVEN -- ��-- +`�.,.,,,, -- ANCHORS AT 24"O.C. - - - -- _ % - (1)#10-16 SCREW BOTTOM TRACK. ��� PER STUD FLANGE - AT NEW WALLS WITH FINISH FLOOR-TOP OF SLAB ACOUSTIC INSULATION, SET STUD TRACK IN A CONTINUOUS BED OF SEALANT U.N.O. 2 WALL SECTION WITH SOUND INS. 6 WALL BASE DETAIL A-4 SCALE 1" = 1'-0" A-4 SCALE 3" = 1'-0" U U �- U W~ Q U I Q Q W F- Z Ucin U U) w W U) ? Qrn Q mz0 7r-U) J L) o � a ° o DATE: 9/4/20 PERMIT / CONST REVISION 1. 2. 3. 4. 5. 6. 7. 8. DRAWN BY: R.M.T.