Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD MECHANICAL PERMIT • ` COMMUNITY DEVELOPMENT Permit#: MEC2022-00909 Date Issued: 10/17/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S110AD12400 Jurisdiction: Tigard Site address: 10847 SW ANNAND HILL CT Project: Annand Hill Partition, Lot 3, (1 of 2)ADUs Subdivision: ANNAND HILL CT PARTITION Lot: 3 Project Description: Mechanical for lower dwelling in a new multi-family building:(1)mini split heat pump,(1)range hood, (1)clothes dryer exhaust,and(3)bathroom exhaust fans. Contractor: TECHNIQUE HVAC INC Owner: BLUE PALOUSE PROPERTIES LLC 10316 SE 38TH AVE 333 S STATE ST STE V452 PORTLAND, OR 97222 LAKE OSWEGO, OR 97034 PHONE: 503-407-2448 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: MF Heat Pump 10/17/2022 $61.06 Class of Work: NEW Type of Const: VB Duct Work 10/17/2022 $23.32 Occupancy Grp: R-3 Occupancy Load: Range Hood/Other Kitchen 10/17/2022 $33.39 Stories: 1 Clothes Dryer Exhaust 10/17/2022 $33.39 Project Valuation: $7,000.00 Single Duct Exhaust(Bathrooms,Toilet, 10/17/2022 $69.96 Utility Rooms) Plan Review 10/17/2022 $55.28 Fuel Air Handlers Info Process/Archiving-Lg$2.00(over 10/17/2022 $4.00 Fuel Types: Electricity Units<10000 cfm: 11x17) Gas Pressure: Units>10000 cfm: Info Process/Archiving-Sm$0.50(up to 10/17/2022 $4.00 Furnaces Boilers&Compressors 11x17) 12%State Surcharge-Mechanical 10/17/2022 $26.53 Furnaces<100K BTU: 0-3 HP: Furnaces>= 100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: 1 Appliances Vent Fans: 2 Vent Systems: Total $310.93 Hoods: Comm Incinerators: Required Items and Reports(Conditions) Woodstoves: Gas Fireplaces: Clothes Dryers: Other Mach Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules Issued By: � �— Permittee Signature: C 1503.639.4175 by 7:00 a.m.for the next available inspection date This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit APPliCatk I ECEIVE ' FOR OFFICE ESL OAL1 C Received Permit No.: City of Tigard Date/By: /�D 20 �� MEC�� ( � III • 13125 SW Hall Blvd.,Tigard,OR 97223 SEP 2 9 2022 Plan Review Phone: 503.7182439 Fax: 503.598.1960 Other Permit: / } i ■ DatelBy: 10 -1 S IG J .. jl),l f L/i rl}�L i.,,,,,-,,,, Inspection Line: 503.639.4175 CITY OF TIGAHD Date Ready/By' Jsris: ® See Page 2 for Internet: www.tigard-or.gov Notified/Method:�i ;�� Q.. ' Supplemental information BUILDING DIVISION! '�/J TYPE OF WORK COACHERCIAL FEE" SCHEDULE-USE CHECKLIST 1i-' f)?>5'3s" ' Mechanical permit fees*are based on the value of the work ONew construction ❑Addition/alteration/replacement 7 performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other- mechanical materials,equipment,labor,overhead,and profit. Value:S -7Q(}0 sav CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* 0 1-and 2-family dwelling 0 Commercial/industrial ❑Accessory building For special information use checklist. jirMulti-family 0 Master builder D Other: Description Qty. Ea. Total LOT 3 JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 46.75 lob site address: 1 02 -17 Ai hu A ,,,,y(j HI L(_ .-L Lv Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: e5 1 7._.7.--L 4 Furnace 100,000+BTU(ductsivents) 54.91 Heat pump { 61.06 Suite/bldg./apt.no.: Project name: 3 Lu ty, v p cca L.L , Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 /� -' p p _ Residential boiler(radiator or (�P•Nrr f 1Q c_xci-R-'./ 1 l C� hydronic) 23.32 / Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision: Lot no.: Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 y- Flue vent for water heater or gas ma ft.) 5 i A�it`. )iv) P ,1 j j (ir!I, et co IL, fireplace 23.32 C'�/. �' Log lighter(gas) 23.32 V�/tJ/ f'TL� ps 1t7 P. r u O e4-L. Wood/pellet stove 33.39 li ,17 I P(f -)k"in C' 6 l 5'1n 4 u711" (Jvl-te L Wood fireplace/insert 23.32 LYE.&S"1"-- el.ATt'f peA.A 5 sl G,6pr +00T0 WftQ Chimney/liner/flue/vent 23.32 Other: 23.32 0 PROPERTY OWNER © TEr Environmental exhaust and ventilation: Name: Range hood/other kitchen s equipment 33.39 Address: Clothes dryer exhaust 1 33.39 City/State/ZIP: toiletS compartments,uct exhaust(bathrooms, utiliity r ms) 3 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 ❑ APPLICANT 0 CONTACT PERSON Other: 23.32 Fuel piping: Business name: S14.15 for first four;S4.03 for each additional Contact name: Furnace,etc. Gas heat pump Address: Wall/suspended/unit heater City/State/ZIP: Water heater Fireplace Phone:( ) I Fax::( ) Range g E-mail: Barbecue CONTRACTOR Clothes dryer(gas) Other: Business name: / C7.4,(,J/q l.-(� HA i I_C Jai G. MECHANICAL PERMIT FEES i .9°' Address: I,V t 4, c7 cz- 'T eF5-4.4 ,-t/(j___ Subtotal - - �L i Q" .�_ Minimum permit fee(S90.00) City/State/ZIP: �'�)2� (/14 �� -l ZZ Plan review(25%of permit fee) Phone-.(,503 Lia7- 2.C-14-.e, Fax:( ) State surcharge(12%of permit fee) / TOTAL PERMIT FEE CCB lic.: �I C. 6 -A 1 Z This permit applicadon expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signs re. Fee methodology set by Tri-County Building Industry Service Board Print name: fa Act,[e, ft- ,PL C.5 a sJ Date: jab/2`"<" I:\Buildegtpermits\MEC PermitApp 040113.doc 440.4617T(I 1/02/COM/WEB)