Loading...
HomeMy WebLinkAboutReport (6) SILFAB PRIMESILFAB SOLAR'" SIL-380 HC M5, 2D 2-z JU CITY OF TIGARD BUILDING DIVISIGN r�3, •� RELIABLE ENERGY. PROUD DIRECT FROM THE SOURCE . PARTNER OF Introducing Silfab Prime. Designed to outperform. • Dependable, durable, high-performance solar panels engineered for North American homeowners. SILFABSOLAR.COM C E [ 1Ec : _ €-����rhofer c I-t u e�e Intertok Intectek �"• ISE `Chubb provides error and om ss+ao insurance W Wfab Solarfnc - ELECTRICAL SPECIFICATIONS 380 Test Conditions STC NOCT Module Power(Pmax) Wp 380 1 284 Maximum power voltage(Vpmax) V 35.32 32.83 Maximum power current(Ipmax) A 10.77 8.64 Open circuit voltage(Voc) V j 42.17 39.55 Short circuit current(Isc) A 11.36 9.16 Module efficiency % 20.8% 1 19.4% Maximum system voltage(VDC) V 1000 Series fuse rating A Y0 Power Tolerance Wp ! :0% Measurement conditions:STC 1000 W/m'•AM 1.5•Temperature 25°C•NOCT 800 W/m'•AM 1.5•Measurement uncertainty<_3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by±3%. MECHANICAL PROPERTIES/COMPONENTS METRIC IMPERIAL Module weight 19.5kg±0.2kg 43lbs±0.4lbs Dimensions(H x L x D) 1762 mm x 1037 mm x 35 mm 69.4 in x 40.8 in x 1.37 in Maximum surface load(wind/snow)` 5400 Pa rear load/5400 Pa front load 112.8 Ib/ft'rear load/112.8 Ib/ft'front load Hail impact resistance o 25 mm at 83 km/h o 1 in at 51.6 mph Cells 120 Half cells-Si mono PERC 120 Half cells-Si mono PERC 9 busbar-83 x 166 mm 9 busbar-3.26 x 6.53 in Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, DSM antireflective coating DSM antireflective coating Cables and connectors(refer to installation manual) j 1350 mm,e 5.7 mm,MC4 from Staubli 53.15 in,o 0.22 in(12AWG),MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, fluorine-free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IEC 62790 Certified,IP68 rated TEMPERATURE RATINGS WARRANTIES Temperature Coefficient Isc +0.064°/j`C Module product workmanship warranty 25 year;" Temperature Coefficient Voc i -0.28%/°C Linear power performance guarantee 30 years Temperature Coefficient Pmax ��! -0.36%/°C >-97.1%end lst yr NOCT(±2°C) 45-C >-91.6%end 12th yr I >85.1%end 25th yr Operating temperature -40/+8.1'C >82.61!,end 30th yr CERTIFICATIONS SHIPPING SPECS ULC ORD C1703,UL1703,CEC listed,UL 61215-1/-1-1/-2,UL 61730-1/-2, Modules Per Pallet: 26 or 26(California) Product I IEC 61215-1/-1-1/-2"`.IEC 61730-1/-2"`,CSA C22.2#61730-1/-2,IEC 62716 Ammonia Corrosion;IEC61701:2011 Salt Mist Corrosion Certifed,UL Fire Rating:Type 2 Pallets Per Truck 34 or 32(California) Factory IS09001:2015 i Modules Per Truck 884 or 832(California) A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. " 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolaccom Certification in progress. PAN files generated from 3rd party performance data are available for download at:silfabsolar.com/downloads 69.4"[1762mm] E 14"[356mm] 41.3"[1050mm] 14"[356mm] T +1888.781.7074 ION SO LA R.COM Mounting Hole(x4) +� SILFAB SOLAR INC. [12mm]mm] 800 Cornwall Ave - ---- _, Bellingham WA 98225 USA T +1360.569.4733 CD _ info@silfabsolar.com E E SILFABSOLAR.COM 1.4"[35mm ! L1� Mon E rn M 770 Port Drive L1 "o ` o Burlington WA 98233 USA 1 ? \ v M OR T+1360.569.4733 0 0E_ `r 240 Courtneypark Drive East 3 0.06" 53.15" t`! c Mississauga ON L5T 2Y3 Canada 1.5mm a T +1905.255.2501 [1350mm] �� i F+1905.696.0267 I I t7 7 Cable Length o t c9 rainage Hole(x8) j Silfab-SIL-380-HC-20211101 No reproduction of any kind is allowed without permission Data and information issubjectto - " --- - modifications without notice.©Silfab Solar Inc., 2021.Silfab Solar"'is a trademark of Silfab Solar Inc. 2.4"[60mm] 8' [200mm] Data Sheet Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready Enphase IQ 7 Micro" and Enphase IQ 7+ MicroT" IQ 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ EnvoyTM, Enphase IQ BatteryTM, and the Enphase EnlightenTMmonitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable Optimized for high powered 60-cell/120 half-cell and 72- cell/144 half-cell*modules More than a million hours of testing Class II double-insulated enclosure m UL listed Smart Grid Ready Complies with advanced grid support,voltage and frequency ride-through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) *The IQ 7+Micro is required to support 72-cell/144 half-cell modules. To learn more about Enphase offerings,visit enphase.com E N P H A S E 1 � Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235W-350W+ 235 W-440 W+ Module compatibility 60-cell/120 half-cell PV modules 60-cell/120 half-cell and 72- only cell/144 half-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22V/48V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208V/ 240V/ 208V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6% 97.6% 97.5% 97.3% - CEC weighted efficiency 9 7.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at ht3 s� //ennhase com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com E N P H AS E O 2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7,Enphase IQ 7+,Enphase IQ Battery, g Enphase Enlighten,Enphase IQ Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.2020-08-12 R E c o F a s t e n v For InstaL[ers. By InstaLters. i COMPLETE RAIL- BASED RACKING SYSTEM � INSTALLATION GUIDE co INSTALLATION GUIDF Osten, For Insta[ters. By InstalLers. Clicking the page name will take you to that page TABLE...OF CONTENTS.................................................PAGE...01.. FEATURES...&..B.E.N.E.F.I.TS..............................................PAGE...02. 'INTRODUCTION................................................................PAGE...03. .OVERVIEW................................................................................PAGE 04 .C.O.M.P.Q.N.E.N.T.S.....................................................................PAGE...05. RATINGS.....................................................................................PAGE 06 ARRAYLAYOUT PAGE 07.................................................................................................. .................................... .14STA.L.LATION...................................................................PA.G.E...08. GROUNDING PAGE 17 x . ....................................................................................................................................... A.C.C.E.S.S0.111I.E.S......................................................................PA.G.E....21.. .... ... ... .. .. ....... ..... ... .. ....... ... ... ..... .M.O.D.P.L.P...LIST.......................................................................PAGE...27. N CLAMP PARIXUN.B.ERS..........................................PAGE...3.6. co asten. INSTALLATION GUIDE Fo[ Installers. By InstaLters. CLICKFIT ClickFit conforms to UL 2703 and is one of the fastest installing rail-based systems in the industry. Thanks to its Click-In Rail assembly, the rails can be connected to any of ' EcoFasten's composition shingle, tile, and metal roof mounts in seconds without the need for fasteners or tools. The ClickFit system is made of robust materials, such as aluminum and coated steel, to ensure corrosion resistance and longevity. ClickFit has been tested in extreme weather conditions including wind, fire, and snow. ` FEATURES Tool and fastener free rail attachment • Fully integrated bonding • Click-on Mid & End Clamps • Compatible with a variety of EcoFasten roof attachments INSTALLATION GUIDE ,,. Eco F as ten,. For Installers. By Instalters. INTRODUCTION This manual describes the installation of the ClickFit mounting system for photovoltaic modules on steep-slope roofs. Described within are details for composition shingle and tile, attachments for ClickFit System. Other roof types as well as all other installation manuals can be found for download at www. EcoFastenSolar.com. GENERAL INSTALLATION CONDITIONS Failure to observe the requirements in this document can lead to the exclusion of all guarantees and product liability. EcoFasten Solar reserves the right to amend this document without prior notice. STABILITY AND CONDITION OF THE ROOF ,k, The roof must be in good condition and strong enough to support the weight of the modules, including the additional equipment, wind and snow loads. When in doubt, consult with the engineer of record, and/or the local building inspector. - } ' APPLICATION RANGE OF CLICKFIT Refer to Compatibility module list at the end of this document. Please refer to the � Ecofasten ClickFit span tables for system structural certification and allowable spans. WARRANTY Guarantee according to the warranty conditions and general terms and conditions of EcoFasten Solar. These conditions can be found on the website at www. EcoFastenSolar.com. LIABILITY EcoFasten Solar cannot accept any liability whatsoever for damage or injury caused by not taking adequate safety precautions or (accurately)following the instructions given, or resulting from negligence during the installation of the product and any corresponding accessories specified in this document. EcoFasten,. INSTALLATION GUIOE OVERVIEW The ClickFit mounting system consists of patented adjustable tile hooks and L feet, rails, and the installation materials required for the mounting of photovoltaic modules on composition shingle or tile roofs. For simplicity, tile hooks and L feet will be referred to as"attachments". ATTACHING TO THE ROOF The attachments are fastened to the rafters. Attachments are height-adjustable to level the system on uneven roof surfaces. ATTACHING THE RAIL The rail assembles to the attachments with a click-connector, or Clicker. The rail simply clicks into place without the use of any tools. p ATTACHING THE MODULES The modules are attached to the rails by means of mid clamps and end clamps. Installer must review module and any 3rd party manufacturer's documentation for y, r 34 compatibility and compliance with warranty terms and conditions. � 5 t n INSTALLATION GUIDE E c o F a s t e n: For InstaLLers. By InstaLl.ers. fir. r SYSTEM COMPONENTS REQUIRED k CLICKFIT RAIL RAIL SPLICE TILE HOOK L-FOOT END CAP MID CLAMP ita END CLAMP SYSTEM COMPONENTS ACCESSORIES AW FRAME MLPE MODULE JUMPER MLPE MOUNT MOUNT Refer to ClickFit Alternate Component Addendum for components not shown ' ■ EcoFasten.INSTALLATION GUIDL For Instatters. By InstaLlers. RATINGS Fire Rating* Class A System Fire Rating Max System Voltage 1500 VDC Max Fuse Rating 40A Certification Conforms to UL STD 2703 Warranty 25 Year Material and Workmanship UL 2703 Markings Product listing label is located on the rail end-caps Roof Pitch 2:12-12:12 UL 2703 Allowable Design Load Rating 10 psf downward,5 psf upward,and 5 psf lateral Max Module Size 25.6 sgft Module Orientation Portrait or Landscape Multiple use Rated Components(Position Independent) Mid Clamp,Frame MLPE Mount and MLPE Mount *Class A System fire rating with Type 1 &2 PV modules.Any module-to-roof gap is permitted,with no skirt required.This rating is applicable with any roof attachment. UL 2703 MARKING EXAMPLE: EcoFasten CODE:ESDEC Company US CLICKFIT SYSTEM Intertek MFG ID •• XXXXXXXCoriforrTl,to LJL STD 0 TORQUE SPECIFICATIONS . Component Lag Screw N/A Fully Seat.Use visual indicator of the black EPDM ring around the bonded washer for torquing. Mid-Clamp 144 End-Clamp 96 Rail Clicker Leveling Bolt 142 Pre-torqued upon delivery.Applies to Tile Hook and L-Foot/Clicker Hook Height Bolt N/A Lightly clamp hook to flush with top of next the row Ground Lug N/A Refer to specific ground lug manufacturer's installation manual MLPE Clip 144 MLPE Mount 144 ..�' 3 I F7L Co asten INSTALLATION GUIDE For InstaLlers. By Instatters. • Refer to span tables, local jurisdiction, or engineer of record specifications when determining setbacks from roof edges, attachment spans, etc. • Mark the perimeter and corners of the array on the roof surface. *Add 3/4" to account for the gap between modules in each direction* • Draw or snap chalk lines where the rails will be installed,(refer to module manufacturer specs to determine allowable mounting locations). T • Locate rafters within the area of the array. It may be necessary to shift the array East or West on the roof in order to fall within the rail cantilever v specs (1/ 3 of span). • Stagger rafters every row if required by the local jurisdiction, engineer of record, or company policy. i co as en, INSTALLATION GUIDE For InstalLers. By InstaLters. A i PRE-INSTALLING RAIL SPLICES 1. Determine the number of rails required per row of modules. 2. Insert a rail splice into one rail. Do not push it past the center bump. 3. Slide the next rail onto the rail splice until the two rail ends meet. 4. Repeat steps 2 and 3 until the desired length is achieved. This is usually easiest to do from the ground. ■ INSTALLATION GUIDE '�� EcoFasten,. For InstaRers. By InstaLLers. INSTALLATION OF FLASHING & L-FOOT • ClickFit for comp shingle roofs uses EcoFasten GF-1 watertight flashing system. • Other roof types may use different EcoFasten Solar ` attachments, visit ecofastensolar.com to learn 4 about other applications. Note the orientation of the L foot and Clicker.The two Clicker"arms"should be facing downslope' INSTALLATION STEPS: MMJ 1. Locate rafter lines. 2. Drill 1/4" pilot holes at all attachment points and back fill using roof- compatible sealant. U) 3. Separate shingles where flashing is to be installed. Insert the flashing so the top portion is under the next row of shingles North. Ensure the flashing is pushed to the third-course of shingle to prevent water infiltration through the vertical joints between shingles. 4. Align GF-1 flashing hole with pilot hole. Insert the lag bolt with pre-installed bonded washer through the L foot and EPDM grommet. Tighten the lag bolt until fully seated. The EPDM Ring visual indicator is the most effective way to ensure a watertight seal. INSTALLATION GUIDE • n, For instaLters. By Instal.l.ers. INSTALLING TILE HOOKS 1. Locate rafters on the roof, mark the tiles to be removed. Hint: In some cases rafter tails are visible at the eaves of the roof, making it easy to find the rough location of the rafters. In other cases,the fascia board may have nail heads visible where it was attached to the rafters. In the worst-case a row of tiles may need to be moved to determine the rafter locations. 2. Slide the the at the desired location upward to expose the roof sub surface. If the tile is to be notched, or if using a replacement flashing, remove it entirely. Clean the sub surface with a brush to remove any debris that could affect the sealing. 3. Locate the rafter center and mark it. ; 4. Place the tile hook with the hook itself in the valley of the next tile below. Drill one 114" pilot hole in the rafter center, taking care to keep the hook in the valley of the tile below. Backfill this hole with a roof- compatible sealant. For flat tiles, try to avoid having the hook land directly under a joint between tiles,this will create a larger gap or more notching than necessary. S. Install one 5/16"x 4"lag screw on the row of holes closest to the tile hook arm. If possible, - install the screw in one of the three holes directly next to the arm. If the lag screw must be installed in one of the seven holes furthest from the arm(denoted by the red rectangle below), install three deck screws in the pattern shown by the green circles below. r _ 6. Adjust the height of the tile hook as necessary using the bolt shown in the fourth image. 7. Flash the surrounding area and lag screw head with roof-compatible sealant as necessary. Refer to Tile Hook Subflashing Installation guide on the next page. 8. Replace the tile that was moved and/or removed, or install the tile replacement flashing. If it is to be notched, mark the tile for notching. Notching can be done with a grinding ; , wheel or by using a chisel. X� a 5. a Ob , w S C 00* i CLICK 0 INSTALLATION GUIDE oOa Ec o Fa ste n For Installers. By Installers. 01 21 w 'c MIV Apply a continuous line of the roofing Lower the sub-flashing over the tile hook base.It may manufacturer's approved sealant on the be necessary to move adjacent tiles to easily lower the underside of the ClickFit tile hook sub-flashing sub flashing onto the roof deck. to fora U-shape around the raised edges. y r EcoFasten recommends following the TRI guidelines Place the sub-flashing over the base of the the hook so three-course sealing method.Start the three-course the flashing covers the entire base. sealing method by applying a layer of roofing mastic over the edges of the tile hook sub-flashing. e - i rt a- Place strips of reinforcing fabric over mastic to Apply a final layer of mastic to completely cover cover approximately 2"from the edge of the the reinforcing fabric.The flashing is now installed PAGE sub-flashing in both directions.Place strips on and sealed. the side first,then the top edge. INSTALLATION GUID1 ... EcoFasten, For Installers. By Instal.ters. CLICKFIT INSTALLATION USING SIMPLEBLOCK-U® PRE-INSTALLATION: The SimpleBlock-U can be installed on many different standing seam profiles. See SimpleBlock-U Installation Manual for compatible and non-compatible standing seam profiles. Be sure that each standing seam is no thicker than Y2"in width. INSTALLATION: O Position the SimpleBlock assembly on the panel O seam. Make sure the block is fully seated on the metal seam. Torque the 2 preinstalled oval point set screws to T 150in-lbs using the included 3/16" hex drive. ' tin s� 2 OIncluded with the block, slide the hex holt into the channel on top of the SimpleBlock-U assembly. 4 G Place the ClickFit Universal L-Foot over the hex bolt ¢'' 3 followed by the serrated flange nut and torque to 150in-lbs. $ jy �AX 4 F .•, EcoFasten,, INSTALLATION GUIDE For Insta[Lers. By InstaLLers. INSTALLING THE RAIL 1. Place the rail in the Clickers. 2. Ensure the rails extend a minimum of 2" past the last attachments in Y each row. , S 3. Push the rail into each L-foot; an audible click should be heard when the rail is fully seated. . . .:... . ..:.. Verify the rail is sitting flush with both ledges. If attachments are extremely misaligned it may be necessary to loosen the leveling a" bolt and adjust the height of the -1 L-foot. Tighten the clamping bolt to 144 in-lbs. 4. Level the rail if necessary by loosening the bolt attaching the Clicker to the L-foot or tile hook. INSTALLATION GUIDE ..• EcoFasten, For Instatters. By InstaLlers. MODULE INSTALLATION INSTALL THE END CLAMPS ON EACH RAIL. ON WHATEVER END YOU ARE STARTING WITIH �a Snap the end clamp onto the rail. 'b Slide the end cap onto the rail. Turn the leg of the end clamp around the cap. 0 PLACE MODULE Place the module on the rail, ensuring the module junction box is up-slope.* 2 0 ALIGN AND TIGHTEN Slide the module to the end clamp and align it with the array corners. Tighten the end clamp to 96 in-lb 3 � ' INSTALLATION GUIDE ..•, E c o F a s t e n,, For Installers. By InstaLters. INSTALLING ADDITIONAL MODULES O CLICK IT ON Click a mid clamp onto each rail. 0 O 2 SLIDE IT UP Slide the mid clamps until they are flush with the side of the existing module. O PLACE AND TIGHTEN Place and slide the next module firmly against the mid clamps. Align the ar bottom edges of the modules. Tighten mid clamps to 144 in-Ib. 2 s. 3 CLICK rEcoFasten, 1 INSTALLATION GUIDEFor InstaHers. By InstalLers. INSTALLING END CLAMPS AT THE END OF A ROW 1. Install the last mid clamps in the row. F 2. Measure the rails from the last mid clamp to the module width plus 1". 3. Cut the rails at this mark.There is some adjustment in the end cap/clamp so it does note need to be a perfect cut. 4. Install end clamps and end caps,tighten to 96 in-lb ALTERNATIVE METHOD: 1. Install the last module in the row, tighten the mid clamps. 2. Using a circular saw with a metal blade, or carefully with a reciprocating saw, cut the rail approximately 1" past the edge of the last module. ri 3. Install end clamps and end caps, tighten to 96 in-Ib Replace the the that was moved and/or removed, or install the the replacement flashing. If it is to be notched, mark the tile for notching. Notching can be done with a grinding wheel or by using a chisel. �y.� . 1 � r_. �y Vp- INSTALLATION GUIDE '.'1coFasten,, _ • BONDING AND GROUNDING BONDING PATHS Bonding paths are carried throughout the array in a variety of ways. They are carried module- to-module and module-to-rail through mid clamps, carried at rail-to-rail connections through the bonding jumpers, and carried row-to-row using bondingjumpers either module-to-module on the module frame or rail-to-rail on the ends of the rails. MID CLAMP 2 mid clamps bonding pairs of modules :.; . x<. GROUNDING LUG 1 ground lug per continuous array of Nona y/Y R k✓*v it r t Y t RAIL SPLICE 1 splice bonding MODULE JUMPER adjacent pair of rails 1 module jumper bonding module to module and row to row INSTALLATION GUIOE ', ' C 0 asten, For InstaHers. By InstalLers. GROUNDING 4 .. ........ F s ia'sti= F NECESSARY COMPONENTS One of the following grounding lugs(or any UL 2703 Compliant ground Lug): • BurndyCL50-lTN Ground Lug(UL 2703 - E3514343 / UL 467-E9999) • ILSCO SGB-4 Ground Lug (UL 2703 - E354420/ UL 467- E34440) • ILSCO GBL-4DBT(UL 2703- E354420/ UL467- E34440) • ILSCO GBL-4DBTH (UL 2703 - E354420 / UL 467 - E34440) k • ILSCO GBL-4SS(UL 2703- E354420/ UL 467 - E34440) *Equipment grounding wire should be sized in accordance with the National Electrical Code, NFPA70 and a minimum of 1/4"clearance is required between bare copper wires and aluminum components. CLICK 0 INSTALLATION GUIDE 1O1 EcoF us ten For Installers. By Installers. Lower the MLPE Mount to the rail Tilt and hook the mount around the top"dog ear"of the rail Set the MLPE Mount flush with the top of the rail We the microinverter flange between the MLPE Mount and the serrated bolt flange ■�A Tighten the bolt to 144 in-lbs Repeat this process for all other microinverter and/or optimizer installations PAGE 19 CLICK INSTALLATION GUIDE aoD Ec o Fa ste n For Installers. By Installers. With the ClickFit Rail in place and the Wire Clip in hand, place the wire end on either side of the rail. With the wire end K touching the bottom lip vN of the rail, roll and click- in the Wire Clip to the opposite end of the rail. You will hear an audible ' click when the Wire Clip is set in place. ,4 PAGE 20 INSTALLATION GUIDE EcoFasten, FRAME MLPE MOUNT R^ i INSTALLING THE FRAME MLPE MOUNT ACCESSORY: • Install the Frame MLPE Mount • Slide the Frame MLPE Mount onto the lip of the micro-inverter/power optimizer. ; • Slide the micro-inverter/power optimizer into the opposite lip of the module frame. • Tighten the bolt to 144 in-Ib to clamp the Frame MLPE Mount to the module frame and the micro-inverter/power optimizer to the Frame MLPE Mount. • Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power ` optimizer flange is tight against the clip flange to avoid rotation during tightening. , t FRAME MLPE MOUNT AND MLPE MOUNT ARE COMPATIBLE WITH: • ENPHASE: M250-72, 250-60, M215-60, C250-72, S230, 5280, IQ 6, IQ 6+, IQ7, IQ 7A, IQ 7+, IQ7 I PD, IQ 7X, Q Aggregator; IQ8-60, IQ8PLUS-72, IQ8H-72, IQ81-1-208-72, IQ81-1-240-72, IQ8M-72, may be followed by-2-US • SOLAREDGE: M1600, P300, P320, P340, P370, P400, P401, P405, P485, P505, P600, P700, P730, P800p, P800s, P801, P850, P860, P950, P960, P1100, P1101, 5440, 5500 • SEE PAGE 26 FOR COMPATIBLE MODULE LIST INSTALLATION GUIDE EcoFasten,, For Installers. By Installers. MODULE MAINTENANCE AND SERVICING During servicing or maintenance, module removal may disrupt the bonding path and could introduce the risk of electric shock. If module removal is required for servicing, then a Module Jumper shall be installed to the adjacent modules to maintain the bond path. Modules should only be removed by qualified persons in compliance with the instructions in this manual. a� E 4" Bond Path Grounding Lug Equipment Grounding Conductor(EGC) generally to earth ground Brackets/Mid-Clamps Module jumper k I EcoFasten. INSTALLATION .,••. For Insta[Lers. By InstaLLers. JUNCTION BOX INSTALLATION JUNCTION BOX PREP Prior to installation, use step drill bit to place pass through holes for conduits or water-tight connectors. Drill bit starter locations are provided on the sides and front of enclosure. Do not install conduit facing up roof. CJ RAIL INSTALLATION Use rail-specific MLPE mounting hardware to attach Rail Hangers to rail. Ensure junction box is pushed as close to the rail as possible.Torque to 80-in lbs(1/2"or 7/16" socket), do not overtighten. *lf installing in areas with ground snow loads greater than 40 psf,install junction Box under module directly next to module frame edge. PAGE INSTALLATION GUIDE "le�V ,' E c o F a s t e n, For Installers. By InstaLLers. JUNCTION BOX INSTALLATION DECK SCREWS WITH SEALING WASHERS(2X) DECK MOUNTED INSTALLATION Align sealing oval of box to align with mating feature on flashing.An EPDM foam gasket is pre-installed to the underside of the junction box to seal the flashing to the box without the need for additional sealant. Secure with supplied#12 x 1- "deck screws(2x)until the junction box is pulled tight to the flashing. Do not over-tighten screws to avoid stripping ` °� `' screws in OSB. *If installing pass through fittings,ensure that theJunction Box and roof deck are both properly prepared.Complete installation process before attaching theJunction box to the deck. I I FINALIZING INSTALLATION Install wiring, conduit and fittings per NEC requirements and following local AHj guidance. Using Philips Head Driver tighten the bolt. i For additional details refer to the full junction Box Installation Manual. INSTALLATION , '.' EcoFast h For InstatLers. By Installers. SKIRT INSTALLATION (OPTIONAL) The skirt is designed to give the rows of the array facing the eave of the roof a uniform appearance.The installation consists of three basic components listed below. op 'POO SKIRT& END CAP SKIRT CLAMP 1. Once the first row of modules is installed (or after the array is complete ), locate the correct length and number of skirts for the array. 2. Locate the correct amount of skirt clamps for the array. 80"skirts are preferred when applicable.The general rule when using 80"skirts is the number of modules plus one for the , , end of the array. When using 65"skirts, the rule changes to 2 skirt clamps per module. The general rule is number of modules plus one for the end of the array. If you have ten modules you will need eleven skirt clamps. In the case of heavy snow loads or other circumstances call s; EcoFasten Solar for additional instructions. 3. Working with a helper, align the end of the skirt with one edge of the array, drop the first skirt � clamp onto the module and skirt, ensure all flat faces are parallel and fully engaged with each other. Skirt clamps must be installed within 10 inches from the end of the Skirt. Ensure the clamp is engaging either the top of the skirt or the step depending on the module size.Tighten bolt to 12 ft-Ib. ' 4. There should be enough play in the assembly to drop the next skirt clamp onto the next module at roughly the same location relative to the clamp on the last module. Ensure all faces are parallel and fully engaged with each other. Slide next skirt over the skirt end cap or coupling of the first skirt.Tighten bolt to 12 ft-Ib. ,, 5. Repeat steps 3 and 4 until the end of the array is reached. Install a skirt clamp within 10 Y. inches from the end of the array. Cut the skirt flush with the end of the array as necessary. An additional skirt clamp may be necessary to hold a short piece of skirt at the end of the array. r '< 6. Once the last skirt is cut and clamped in place, install an end cap in the end of the last skirt. To ensure the end cap stays in place through various weather conditions, it is acceptable to install a small amount of roof sealant onto the edge of the end cap that will contact the inside face of the skirt. Replace the the that was moved and/or removed, or install the tile replacement flashing. If it is to be notched, mark the the for notching. Notching can be done with a grinding wheel or by using a chisel. INSTALLATION GUIDE ,.•,• co as en,, For Instal[ers. By InstaRers. a Install first skirt clamp within 10 inches from the end of the array with 80"skirts, the second clamp location will be similar to the first clamp but installed on the second module. Continue to the end of the array. Q . Install last skirt clamp within 10 inches from the end of the array prior to cutting. Install end cap on the last module.Adding a small amount of sealant is optional. 3 � I THINGS TO CONSIDER PRIOR TO INSTALLING THE SKIRT ARE: • Potential snow drifting in the area the skirt is to be installed. If the snow load is greater than 20psf in your region two skirt clamps are required per module and skirt coupler must be used. Contact EcoFasten for information on the skirt coupler. • There are three options for skirts: A, B and C.The A& B skirts can be identified by looking at the inner channel, if it's ribbed then it is a B skirt and will use 32mm (inner channel) and 38mm utilizing the top of the skirt.A skirts will have a smooth inner channel and use , 35mm (inner channel) and 40mm utilizing the top of the skirt. C skirts will only use 30mm skirts and do NOT have an inner channel. • ,:. DE co as en, • UL 2703 CERTIFIED MODULES This racking system may be used to ground and/or mount a PV module complying with UL 1703 or UL 61730 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. MANUFACTURER LIST OF APPROVED MODULES Adani modules with 35 and 40mm frames Adam ASX-Y-ZZ-xxx Where"X"can be B, M or P, "Y"can be 6 or 7, and "ZZ"can be blank, PERC, B-PERC, or AB-PERC Aionrise modules with 35 and 40mm frames Aionrise AIONyyG1-xxx Where"yy"can be 60 or 72 Amerisolar modules with 35, 40 and 50 mm frames Amerisolar AS-bYxxxZ Where"b"can be 5 or 6;"Y"can be M, P, M27, P27, M30, or P30; and""Z"" can be blank,W or WB Aptos modules with 35 and 40 mm frames Aptos Solar DNA-yy-zzaa-xxx Where"yy"can be 120 or 144;"zz"can be MF or BF; and"aa"can be 23 or 26 Astronergy modules with 30, 35,40, and 45 mm frames aaSMbbyyC/zz-xxx Astronergy Solar Where"aa"can be CH or A; "bb"can be 60, 66, or 72;"yy'can be blank, 10 or 12; "C"can M, P, M(BL), M-HC, M(BL)-HC, P-HC, M(DG), or M(DGT); and "zz"can be blank, HV, F-B, or F-BH ASUN modules with 35 and 40 mm frames ASU N-xxx-YYZZ-aa ASUN Where 'YY can be 60 or 72; ZZ can be M,or MH5; and as can be blank or i BB i Auxin modules with 40 mm frames Auxin AXN6y6zAxxxB Where"y"can be M or P;'Y' can be 08, 09, 10, 11, or 12; and "A"can beF, M or T; and "B"can be blank, A, B or C k 8 ' 4'0 INSTALLATION GUIDE > E c o F a s t e n Foi Instal[eis. By Installers. a MANUFACTURER LIST OF • MODULES I Axitec Modules with 30,35 and 40 mm frames AC-xxxY/aaZZb Axitec Where"Y"can be M, P or MH; "aa" can be blank, 125- or 156-;"ZZ"can be 54, 60, 72, 108, 120, or 144; "b"can be S, X, V,VB, XV, or MX Boviet modules with 35 and 40mm frames Boviet BVM66aaYY-xxxBcc Where"aa"can be 9, 10 or 12; "YY"is M, or P; and "B"can be blank, L or S; and"cc"can be blank, H, H-BF, H-HC, HC-BF or H-HC-BF BYD modules with 35 mm frames BYD BYDxxxAY-ZZ Where"A"can be M6, P6, MH or PH; "Y"can be C or K; and "ZZ"can be 30 or '36 Canadian Solar modules with 30, 35 and 40 mm frames Canadian Solar CSbY-xxxZ Where"b"can be 1, 3 or 6;"Y"can be H, K, L, N, P, U,V, W,X or Y; and"Z" can be M, P, MS, PX, M-SD, P-AG, P-SD, MB-AG, PB-AG, MS-AG, or MS-SD CertainTeed modules with 35 and 40mm frames CertainTeed CTxxxYZZ-AA Where"Y"can be M, P, or HC;"ZZ" can be 00, 01, 10, or 11; and "AA"can be 01, 02, 03, 04 or 06 Csun modules with 35 and 40 mm frames CSUN YYxxx-zzAbb Where"YY"is CSUN or SST;"zz"is blank, 60, or 72; and"A"is blank, P or M or MM;"bb" is blank, BB, 5BB, BW, or ROOF Dehui modules with 35 and 40mm frames i Dehui DH-MYYYZ-xxx Where"YYY"can be 760, 772, 860, 872; and "Z" can be B or W I Ecosolargy modules with 35,40, and 50 mm frames ECOxxxYzzA-bbD ECosO argy U . Where"Y"can be A, H, S, or T;"zz" can be 125 or 156;"A"can be M or P;"bb" can be 60 or 72; and "D"can be blank or B i ET Solar modules with 35,40,and 50 mm frames ET-YZZZxxxAA ET Solar Where"Y"can be P, L, or M; "ZZZ"can be 660, 660BH, 672, 672BH, 754BH or 766BH; and "AX can be TB,TW, WB,WW, BB,WBG, WWG,WBAC,WBCO, WWCO,WWBCO or BBAC INSTALLATION GUIDE / F / s t • n, For Installers. By InstaLters. APPROVEDMANUFACTURER LIST OF UL 2703 • � . Flex modules with 35,40, and 50 mm frames ' Flex FXS-xxxYY-ZZ; Where"YY"can be BB or BC; and"ZZ"can be MAA1 B, MAA1 W, MA131 W, SAA1 B, SAA1 W, SAC1 B, SAC1 W, SAD1 W, SBA1 B, SBA1 W, SBC1 B, or SBC1 W GCL modules with 35 mm and 40 mm frames GCL GCL-ab/YY xxx Where"a"can be M or P; "b"can be 3 or 6; and "YY"can be 60, 72, 72H, or 72DH Gigawatt modules with 40 mm frames GigaWatt Solar GWxxxYY Where"YY"can be either PB or MB Hansol modules with 35 and 40 frames Hansol HSxxxYY-zz Where"YY"can be P6, PD, PE,Te,TD, UB, UD, or UE; and "zz"can be AH2, AN1,AN3,AN4, HH2, HV1, orJH2 Hanwha Solar modules with 40,45, and 50 mm frames LM Hanwha Solar HSLaaP6-YY-1-xxxZ Where"aa"can be either 60 or 72;"YY"can be PA or PB; and "Z"can be blank or B Hanwha Q CELLS Modules with 32, 35, 40, and 42mm frames aaYY-ZZ-xxx where"aa"can be Q. or B.; "YY"can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, PLUS DUO or PEAK DUO; and "ZZ"can be G3, G3.1, G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4Z/TAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/ SC, G4.1/TAA, G4.1/MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK Hanwha Q CELLS G4.1/SC, EC-G4.4, G5, G5/SC, G5/TS, BLK-G5, BLK-G5/SC, BLK-G5/TS, L-G5, L-G5.1, L-G5.2, L-G5.2/1-1, L-G5.3, G6, G6/SC, G6/TS, G6+, BLK-G6, L-G6, L-G6.1, L-G6.2, L-G63, G7, BLK-G6+, BLK-G6+/AC, BLK-G6+/HL, BLK-G6+/SC, BLK-G6/TS, G6+/TS, BLK-G6+/TS, BLK-G7, G7.2, G8, BLK-G8, GB+, BLK-G8+ L-G7, L-G7.1, L-G7.2, L-G7.3, L-G8, L-G8.1, L-G8.2, L-G8.3, L-G8.3/BFF, ML-G9, BLK ML-G9, ML-G9+, BLK ML-G9+, BLK-G10+, BLK-G10+/AC, ML-G10, BLK ML-G10, ML-G10+, BLK ML-G10+, ML-G10.a, BLK ML-G10.a, ML-G10.a+, BLK ML-G10.a+,XL-G9, XL-G9.2, XL-G93,XL-G10.2, XL-G10.3,XL-G10.c or XL- " G10.d z w • NOW CLICK INSTALLATION GUIDE .,.•. EcoFasten MANUFACTURER LIST OF . • MODULES Heliene modules with 40 mm frames YYZZxxxA Heliene Where"YY"can be 36, 60, 72, 96, 120 or 144;"ZZ"can be HC, M, P, or MBLK; and "A"can be blank, HomePV, or Bifacial i HT-SAAE modules with 35 and 40 mm frames HT-SAAE HTyy-aaaZ-xxx Where"yy'can be 60, 66 or 72;"aaa"can be 18, 156 or 166;"Z"can be M, P, M-C, P-C, M(S), M(VS), M(V), P(V), M(V)-C, P(V)-C, or X Hyundai modules with 33, 35,40 and 50 mm frames Hyundai H iY-SxxxZZ Where"Y"can be A, D or S; "S"can be M or S; and "ZZ"can be HG, HI, KI, MI, MF, MG, PI, RI, RG, RG(BF), RG(BK), SG,TI or TG Itek Modules with 40 and 50 mm frames Itek IIT-xxx-YY Where"YY"can be blank, HE, or SE, or SE72 JA Solar modules with 30, 35,40 and 45 mm frames I JAyyzz-bbww-xxx/aa Where"yy'can be M, P, M6 or 136; "zz"can be blank, (K), (L), (R), (V), (13K), (FA), JA Solar (TG), (FA)(R), (L)(BK),(L)(TG), (R)(BK),(R)(TG), (V)(BK), (BK)(TG), or(L)(BK)(TG); i "bb"can be 48, 54, 60, 66, 72 or 78; "ww" can be D09, S01, S02, S03, S06, S09, S10, S12, S17, S20, S30 or S31; and "aa"can be BP, MR, SI, SC, PR, 3136, 4136,4136/RE, 5136 Jinko modules with 35 and 40 mm frames JKMYxxxZZ-aa Where"Y"can either be blank or S;"ZZ"can be M, P, or PP; and "aa"can be jinko blank, 60, 60B, 60H, 60L, 6013L, 60HL, 60HB, 60HBL, 6HBL-EP, 60-J4, 6013-J4, I 60B-EP, 60(Plus), 60-V, 60-MX, 6RL3, 6RL3-B, 6TL3-B, 7RL3-V, 7RL3-TV, 72, 72B, 72J4, 72B-J4, 72(Plus), 72-V, 72H-V, 72L-V, 72HL-V, 72-MX, 72H-BDVP, 72HL-TV,or 72HL-V-MX3 � _ v *� Kyocera Modules with 46mm frames . KYxxxZZ-AA Kyocera Where"Y"can be D or U; "ZZ"can be blank, GX, or SX; and "AA"can be LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LF132, LPB2, 3AC, 3BC, 3FC,4AC, 413C,4FC, 4UC, 5AC, 513C, 5FC, 5UC, 613C, 6FC, 813C, 6MCA, or 6MPA LG modules with 35,40,and 46 mm frames LG LGxxxYaZ-bb Where"Y"can be A, E, M, N,Q,S;"a"can be A, 1,2 or 3;"Z"can be C, K,T, or W; , and"bb"can be A3,A5,A6, B3, B6, E6, E6.AW5,G3,G4,J5, K4, 1-5, N5,V5,V6 ' i INSTALLATION GUIDEEcoFasten For Instal[ers. By Installers. MANUFACTURER LIST OF i APPROVED M • Longi modules with 30, 35 and 40 mm frames LRa-YYZZ-xxxM Longi Where"a"can be 4 or 6;"YY"can be blank, 60, 66 or 72; and "ZZ"can be blank, BK, 1313, HV, PB, PE, PH, HBD, HIB, HIH, HPB, HPH, or HIBD Mission Solar modules with 33, 35 and 40 mm frames YYYbb-xxxZZaa Mission Solar Where"YYY"can be MSE or TXS; "bb"can be blank, 6 or 60A; "ZZ"can be blank, MM, SE, SO, SQ , SR, SX,TS, 120 or 144; and"aa"can be blank, BB, BW, 1J,4J, 4S, 5K, 5R, 5T, 60, 6J, 6S, 6W, 6Z, 8K, 8T, or 9S Mitsubishi modules with 46 mm frames Mitsubishi Pv-MYYxxxzz Where"YY"can be LE or JE; and"ZZ"can be either HD, HD2, or FB Motech IM and XS series modules with 40, 45, and 50 mm frames Next Energy Alliance modules with 35 and 40mm frames Next Energy Alliance yyNEA-xxxZZ where"yy"can be blank or US;"ZZ"can be M, MB or M-60 Neo Solar Power modules with 35 mm frames D6YxxxZZaa Neo Solar Power Where"Y"can be M or P;"ZZ"can be 133A, B4A, E3A, E4A, H3A, H4A; and"aa" can be blank, (TF), ME or ME (TF) Panasonic modules with 35 and 40 mm frames Panasonic (HIT) VBH NxxxYYzzA Where"YY"can be either KA, RA, SA or ZA;"zz"can be either 01, 02, 03, 04, 06, 068, 11, 11 B, 15, 1513, 16, 166, 17, or 18; and"A"can be blank E, G or N Panasonic Panasonic modules with 30 mm frames (EverVolt) EVPVxxxA Where"A"can be blank or H, K or PK Peimar modules with 40 mm frames SbxxxYzz Peimar Where"b"can be G, M or P; "Y"can be M or P; and"zz"can be blank, (BF), or (FB) Philadelphia modules with 35 and 40 mm frames PS-YzzAA-xxx Philadelphia Solar Where"Y"can be M or P;"zz"can be 60, 72 or 144; and"AA" can be blank, (BF), (HC)or(HCBF) y INSTALLATION GUIIJE E c o F a s t ' MANUFACTURER LIST OF APPROVED • Phono Solar modules with 35,40, and 45 mm frames PSxxxY-ZZ/A Phono Solar Where"Y"can be M, M1, MH, M1 H, M4, M41-1, or P; "ZZ"can be 20 or 24; and "A"can be F,T, U, UH, or TH Recom modules with 35 and 40 mm frames ReCom RCM-xxx-6yy Where"yy'can be MA, MB, ME or MF REC modules with 30, 38 and 45 mm frames RECxxxYYZZ REG Solar Where"YY"can be AA, M, NP, NP2, PE, PE72, TP,TP2,TP2M,TP2SM,TP2S, TP3M or TP4; and "ZZ"can be blank, Black, BLK, BLK2, SLV, 72 or Pure I ReneSola modules with 35, 40 and 50 mm frames AAxxxY-ZZ I Renesola Where"AA"can be SPM(SLP) or JC; "Y"can be blank, F, M or S; and "ZZ" U3 can be blank,Ab,Ab-b,Abh,Abh-b,Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, Db-b, or 24/Bb Renogy Modules with 40 and 50 mm frames Renogy RNG-xxxY Where"xxx"is the module power rating; and"Y"can be D or P Risen Modules with 35 and 40 mm frames Risen RSMyy-6-xxxZZ Where"yy"can be 60, 72, 120, 132 or 144; and"ZZ"can be M or P S-Energy modules with 35 and 40mm frames SABB-CCYYY-xxxZ S-Energy Where"A"can be C, L or N;"BB"can be blank, 20,40 or 45; "CC"can be blank, 60 or 72;"YYY"can be blank, MAE, MAI, MBE, MBI, MCE or MCI; and "Z"can be V, M-10, P-10 or P-15 SEG Solar modules with 35 and 40 mm frames SEG-aYY-xxx-ZZ SEG Solar Where"a"can be blank, 6 or B; "YY"can be blank, MA, MB, PA, or PB; and , B ZZ"can be blank, BB, BG, BW, HV, W ,WW, BMB, BMA-HV, BMA-TB, BMB- HV, BMB-TB, BMD-HV Seraphim modules with 35, 40 and 50 mm frames SRP-xxx-YYY-ZZ Seraphim USA Where"xxx"is the module power rating; and "YYY"can be 6MA, 6MB, 6PA, 6PB, BMD, 6QA-XX-XX, and 6QB-XX-XX; ZZ is blank, BB or HV 4 - x. ♦ ♦ h EcoFastenINSTALLATION GUIDE For Insta([ers. By InstaLlers. MANUFACTURER LIST OF APPROVED M • Sharp modules with 35 and 40 mm frames Sharp NUYYxxx Where"YY"can be SA or SC Silfab Modules with 35 and 38 mm frames Siifab SYY-Z-xxxAb Where"YY"can be IL, SA, LA, SG or LG; "Z"can be blank, M, P, or X; "A"can be blank, B, H, M, N; and"b"can be A, C, G, K, L, N,T, UorX Solaria modules with 35 and 40 mm frames Solaria PowerXT-xxxY-ZZ Where"Y"can be R or C; and "ZZ"can be AC, BD, BX, BY, PD, PL, PM, PM-AC, PX, PZ,WX or WZ Solarcity modules with 40 mm frames SOlarcity s (Tesla) cxxxYY Where'W'can be blank, B1 or B2 SolarTech modules with 40 and 42 mm frames SolarTech AAA-xxxYY Where"AAA"can be PERCB-B, PERCB-W, HJTB-B, HJTB-W or STU;"YY"can be blank, PERC or HJT SolarWorld Sunmodule Plus, Protect, Bisun,XL, Bisun XL, may be followed SolarWorld AG by mono, poly, duo, black, bk, or clear; modules with 31, 33 or 46 mm frames SW-xxx j II OrSolarWorld Sunmodule Plus, Protect, Bisun,XL, Bisun XL, may be followed Americass by mono, poly, duo, black, bk, or clear; modules with 33 mm frames = Americas SWA-xxx Sonali Sonali Modules with 40 mm frames SSxxx Stion Stion Thin film modules with 35 mm frames STO-xxx or STO-xxxA SunEdison Modules with 35, 40& 50 mm frames SE-YxxxZABCD E SunEdISOn Where"Y"can be B, F, H, P, R, or Z; "Z"can be 0 or 4;"A"can be B, C, D, E, H, I,J, K, L, M, or N ; "B"can be B or W; "C'can be A or C;"D"can be 3, 7, 8, or 9; <. and"E"can be 0, 1 or 2 Suniva modules with 35, 38,40, 46, and 50 mm frames ' "`' `1% OPTxxx-AA-B-YYY-Z Suniva MVXxxx-AA-B-YYY-Z Where"AA" is either 60 or 72;"B"is either 4 or 5;"YYY" is either 100,101,700,1 B0, or 1 B1; and"Z"is blank or B b EcoFasten INSTALLATION 1 For Installers. By Installers.,. �a MANUFACTURER LIST OF • MODULES Sunpower standard (G3 or G4)or InvisiMount(G5)35,40 and 46 mm frames Sunpower SPR-Zb-xxx-YY Where"Z" is either A, E, P, M or X; "b"can be blank, 17, 18, 19, 20, 21, or 22; and'W'can be blank, BLK, COM, C-AC, D-AC, E-AC, BLK-E-AC, G-AC, BLK-C- AC, or BLK-D-AC Sunspark modules with 40 mm frames Sunspark SYY-xxxZ-A Where"YY"can be MX or ST; and "Z"can be M, MB, M3, M313, P or W; and "A"can be 60 or 72 Suntech Modules with 35,40 and 50mm frames Suntech STPxxxy-zz/aa Where"y"is blank or S; and "z"can be 20, 24,A60 or A72U; and "aa"can be Vd,Vem,Vfw,Vfh, Wdb, Wde,Wd, or Wfhb Talesun modules with 35 and 40mm frames Talesun TP6yZZaaxxx-b Where"y"can be blank, F, H, or L; "ZZ"can be 60 or 72;"aa"can be M, M(H), or P; and "b"can be blank, B,T, or(H) Tesla modules with 40 mm frames Tesla TxxxY Where"Y"can be H or S Trina Modules with 30, 35, 40 and 46mm frames TSM-xxxYYZZ �� Where"YY"can be DD05, DD06, DD14, DE09, DE14, DE06X, DE15, DE15V, Trina DEG15, PA05, PC05, PDOS, PD06, PA14, PC14, PD14, PE14, or PE15 ; and "ZZ" can be blank, (II), .05, .05(11), .08, .10, .18, .08D, .18D, 0.82, .002, .00S, 055, 08S,A,A.05, A.08, A.10,A.18,A(II), A.05(II),A.08(ll),A.082(11), A.10(II), A.18(II), H, H(II), 1-1.05(II), H.08(II), HC.20(II), HC.20(II), M, M(11), M.05(11), MC.20(II) URE modules with 35 mm frames URE DyZxxxaa Where"D"can be D or F,"y"can be A, 6 or 7;"Z"can be K or M; and "aa"can be H3A, H4A, HBA, E7G-BB, E8G or E8G-BB Vikram solar modules with 40 mm frames : VSyy.ZZ.AAA.bb Vikram Where"yy"can be M, P, MBB, MH, MS, MHBB, or PH; "ZZ"can be 60 or 72; -: ' "AAA" is the module power rating; and"bb"can be 03, 04 or 05 INSTALLATION JE • n; LIST MANUFACTURER OF • MODULES VSUN modules with 30, 35 and 40 mm frames VSUN VSUNxxx-YYz-aa Where"YY"can be 60, 72, 108, 120, or 144;"z"can be M, P, MH, PH, or BMH; and "aa"can be blank, BB or BW Waaree modules with 40mm frames Waaree WSyy-xxx where"yy"can be blank or M Winaico modules with 35 and 40 mm frames Winaico Wsy-xxxZa Where"y"can be either P or T;"Z"can be either M, P, or MX; and"a"can be blank or 6 # ( Yingli modules with 35 and 40 mm frames Yingii YLxxxZ-yy I Where"Z"can be D or P;"y('can be 29b, 30b, 34d, 35b, 36b or 40d ZN Shine modules with 35mm frames ZN Shine ZXMY-AAA-xxx/M Where"Y"can be 6 or 7,"AAA"can be 72, NH120, NH144 or NHDB144 �"11 N� ' CLICK INSTALLATION , ''1 For Instat[ei s. By InstaLlers. CLAMP PART NUMBERS �XX . Frame Thickness Article Number 30 mm 2099016 32 mm 2099017 35 mm 2099018 38 mm 2099019 40 mm 2099020 45 mm 2099021 Frame Thickness Article Number 30-40 mm 2099022 40-50 mm 2099023 INSTALLER RESPONSIBILITIES Periodic re-inspection of components shall be performed to verify that there is no corrosion detrimental to system strength and electrical conductivity, no loose bolts,and/or other variables that could compromise array safety.Any corroded or damaged components shall be immediately replaced. • ,�,7,>- Ecc)Fusten, For InstaRers. By Installers. PLETE MOUNT & MASHING ASSEMBLY INSTALLATION GUIDE REVISION: 04/05/22 - - - VERSION: '.'24 - - I 0 0 G F =1 .0 .,6r .0 INSTALLATION GUIDEFor Installers. By Instalters. 4� CLICKING THE PAGE NAME WILL TAKE YOU TO THAT PAGE TABLE OF CONTENTS PAGE 01 FEATURES & BENEFITS PAGE 02 COMPONENTS PAGE 03 ujIn INSTALLATION PAGE 04 LI.N.E...D.RAWI.N G.S.............................................................PAG E..0.6. SPECIFICATIONS PAGE 12 ..................................................................................................................................... ANOM 1 ��• p ®�oirvisro a GFml ECOF us ten INSTALLATION GUIDE For InstaHers. By Installers. a =a O ;y STATE OF .�s eeo 0R10 C�TY HUKF�CP♦ `OPVVaa GF-1 GF-1 is our most versatile solution for composition shingle roofs. Install the flashing s using a single fastener for a quick & easy installation. When using the GF-1 flashing grommet and an EcoFasten compression bracket, a watertight seal is created, maintaining the integrity of the roof. FEATURES � 4 • Mill or black finish • Patented Watertight Technology • Installs without removing shingles ; • Single lag bolt attachment • Compatible with a variety of compression brackets • Florida Product Approved for any combinationof 8"x12"GF-1 flashing with the ClickFit L-foot& Lag Screw G Fml 'y' INSTALLATION1 SYSTEM COMPONENTS 1 2 3 4 1. L-FOOT SCL-101 BLK 3 4. GF-1 FLASHING GLV MLL 8X12 - (OTHER OPTIONS AVAILABLE) GALVALUME FLASHING WITH PRE- INSTALLED EPDM RUBBER GASKET 2. 5/16" LAG BOLT (AVAILABLE IN 3" AND 4") (AVAILABLE IN 8X10&8X12,WITH MILL&BLACK FINISH OPTIONS) 3. 5/16" EPDM BONDED WASHER 0 6 F =1 �,� - INSTALLATION GUIDEFor Instatters. By Instatters. INSTALLING GF-1 Snap horizontal lines across the roof to mark the mount rows, then locate the rafter and mark the installation position of each GF-1 flashing, '��_� b 44 Drill a 7/32" pilot hole into the rafter or structural member for the lag screw. Backfill with sealant compatible with the roof type. x'h .�.' MW W i Slide flashing up under the next row of shingles directly above the pilot hole, taking care to align the hole in the flashing with the pilot hole. 0 GF =1 ,4 EcoFasten .0 INSTALLATION GUIDE For InstaHers. By InstaLlers. INSTALLING GF-1 Thread the EPDM bonded washer onto the lag bolt followed by one of EcoFasten's compression brackets and then insert the lag bolt into the gasketed hole in the flashing. ! Drive the lag bolt down into the rafter using an impact driver. a Torque range is between 100-400 � f torque inch-pounds depending ` ' - on the type of wood and time of year.The visual indicator for proper torque is when the EPDM on the underside of the bonded washer _ begins to push out the sides as the i washer compresses. Do not over torque. q,c I .0 G F=1 10 .INSTALLATION GUIDE ,C, 4o For Installers. By InstalLers. A,,.•': CUT SHEET: GF-1 FLASHING GLV MLL/BLK 5 4 ITEM NO. PART NUMBER DESCRIPTION QTY. REV. _-- "T" LAM APPROVED 1 750041-02 GFI-GAL-MLL-812 1 A RELEASE TO ESDEC fORmAi 1EC0%Till sours 2 150002 5/16 STAINLESS STEEL AND EPDM 1 A BONDED SEALING WASHER D cn cm ( 8.00 [203.2] ) 1 C C Waft 12.00 [304.8] POOR B B ^PsM ( 0.02 [0.5]) THIRD ANGLE PROJECTION o wN oin i I RA NS CHECKED PS �roM � EHG PPa R —11SUR, IE APPR.mD I-11— O A ... G.A. 1-11 SUR, DNA AND TOLERANCE INNOVATIVE YOYNTING GVE7BIG DO NOT SCALE DRAWING PERMMEY14.[M]-2009 E RROR�IEIARYRNDCONFIDFN?l DWIENSIONSTOLERANCES ARE N:GF-1 FLASHING GLV MILL HX12 I 1.PACKAGE PER"3012011-PCr' .xx:+/-INCHES. MILLIMETERS 030 .x:+/-�s c.No. aEv. I (GF-I FLASHING GLV MILL 8X12"50-PACK INST) xxx+/.010 xx+i 25 301201 A ANGLES:+/-I- ­LE:1:1 W9GM: 4 P � 4 GFml ,,Cl,. EcoFasten INSTALLATION GUIDE For InstaRers. By InstalLers. IL IL CUT SHEET: L-FOOT L-102 BLK 3" 5 i 4- ITEM REM NO. PART NUMBER DESCRIPTION QTY. REV. - aEo sloes - 1 450050-01 L-102-3 ANDD BLK 1 01 EASE TO ESDCI EoaIAT(El--) w/0a/wa 2 150009-08 SS HEX HD CAP SCREW,FULL THD,3/8-16 UNC X 1.25 LONG 1 01 3 150011-03 SS SERRATED FLANGE LOCK NUT,3/8-16 1 02 D D R 3 3.00 ''. 2 � [76.2] tiS ) * r; B B 1.88 1.92 [47.6] [48.8] ` THIRD ANGLE PROJECTION ° ios2os' HAKE aAT of ° e �A mv°n a]m° ai 2M2 0 A M/C�l]01I INiERRREi G.AND TOLERANCE INNOVATIVE YOUNTNIf fYfTfYf DO NOT SCALE DRAWING vER ASMEY145[M]2oo9 DIMENSIONS TOLERANCES ARE IN. L-FOOT L-102 BLK 311 " 1.PACKAGE PER"301 1015-PCK" vxorxlEraar aeu coNFlOENnnL 6 c INCHES. MILLIMETERS (L-FOOT L-102 BLK 3"50-PACK INST� xx:./.oao .x..i �s ° 3�1 ��5 aA- .x%X./-.010 .%x y.25 6 4 �.3aw ANGLES:./-1° ! z v GF=l 4Ec o F a s t N ' v INSTALLATION GUIDE For kik`'%,A ; x, mak` Se.. 9 CUT SHEET: L-FOOT L-102 MLL 6" fjr - � ITEM NO. PART NUMBER DESCRIPTION QTY. REV. REvlsroNs DSCR PRON D R AFPROVED 1 450082-02 L-102-6 1 01 A R—E To ESDEc FORMA1IEco xRzzl RADUPs },. 2 150009-08 SS HEX HD CAP SCREW,FULL THD,3/8-16 UNC X 1.25 LONG 1 01 wg, 3 150011-03 SS SERRATED FLANGE LOCK NUT.3/8-16 1 02 D cn cm 1 C C 3 ( 6.00 [152.4]) 2 sx , 3.00 [5 00]� �[76.2] !!f THIRD ANGLE PROJECTION CxED pspzrcs�im A MNG Al".minD w/0s/zm D FG AP R r UxNS/A]1 r A L..A? D OxNS/R031 WTERPRET DIM AND TOLERANCE INNOVATIVE YOYM1Mf iYflBli DO NOT SCALE DRAWING PERASMEY14.51M1-2009 I �,E [ PROPRIETARY AND CONEIDENDAL DIMENSIONS TOLERANCES ARE IN: L-FOOT L-102 MLL 6" 1.PACKAGE PER"3011016-PCK" INCNEs. MRL-ERS (nD .XX:y-.030 X: /-J5 30))��6 RA )L-FOOT L-102 MLL 6"50-PACK INST) .XXX:+/-m0 XX,*/-.2s Nc. ANGLES:+/.I° SCAL:II wDGNT:¢eaonartco.corrwnrax�o cw[<xc. .. SHED 1 Of I 6 4 2 ' Xx� .0 �. ; INSTALLATIONG Fml For Instalters. By InstaLLers. R :�� CUT SHEET: L-FOOT SCL-101 MLL/BLK 3" 6 ° 4 , ITEM NO. PART NUMBER DESCRIPTION OTY REV. _ aNVISIn eev. o_scwwrio oA�e APaanve0 1 450049-02 L FOOT W/STANDARD DIMPLE AND OPEN SLOT,31N TALI MI 1 01 - oEsom soaMar IEco a�.el aoasnozi aAouas 2 150009-OS SS HEX HD CAP SCREW,FULL THD,3/8-16 UNC X 1.25 LONG 1 Ol 3 150011-03 SS SERRATED FLANGE LOCK NUT,3/8-16 I 02 D D TT z .;tea,... iC C �1g *4j 3.0 176.2] ) +s I 1.88 3 [47.6] 2 t THIRD ANGLE PROJECTION1AN n ee o oA o aro�snoa _,�, es.r IA �..r�.we mo (N-2ozi 0 A wR-CE 021 INTERPRFt DIMAND TOLERANCE INNOVATIVE MOUNTING fYfitMf DO NOT SCALE DRAWING PERASMEYt4.51M1-zoo, L—FOOT SCL-101 MLL 3" I.PACKAGE PER 301 1 O)7-PCK PRT.OPRIETARY AND C0NEIDENiIAI DIMENSIONS TOLERANCES ARE IN: 1• k INCHES- MILLIMETERS ' E ( FOOT SCL-lO1 MILL 3"50-PACK INST.) xxx+H-o o *L�25 No 3011017 q 3€ f� ANGLES: 1' I—;I.I -I-T I I X\1 G F=1 INSTALLATION GUIDE by- 14", For InstalLers. By Installers. CUT SHEET: CF UNIV L-FOOT MLL 3" - 2012022 -� ITEM NO. PART NUMBER DESCRIPTION QTY. REV. ReasloNs - -"" DESCRPION DAIS OVED 1 750120 CLICKFR L FOOT ASSEMBLY 1 A v PsoEe 10-1 leen«mol e5/9/Q 1 —/1"S D D 1 cm C C ( 2.76 [70.1] ) 8 � B LEE i THIRD ANGLE PROJECTION DRAwN of/zo/wm D�^ C4e-- RSD OS/3I/fiRl (`(JL' ' A A—IN /znm:I rnNG APPR.'A 05/2)/20]1 A O.A. OSl2]/2021 I1 ERRPREIDIM AND T01 RANC E INNOVATIVE MOLWMGE17iSY DO NOT SCALE DRAWING RER nsME YI<.s[M1-2009 ` "ORIIIETARY AND CONPIDFNIIAL DIMENSIONS TOLERANCES ARE IN: CF UNIV L—FOOT MLL 311 INCHES. MA.WnEIERS i 1.PACKAGE PER"2012022-PCK" xx +/-.030 1,Ill sae Dwe.No. 2012022 (CF UNIV L-FOOT MLL Y 50-PACK INST.) .xxx:+/".010 .xx:+/-ss RA uj ANGLES:+/-I- SULE wFiGrt: 64 1 NN I GFml EcoFusten For Installers. By Installers. CUT SHEET: RI COMP SLIDE AL BLK - 2011013 3 REM NO. PART NUMBER DESCRIPTION QTY. REV. DescRPno" 1 450092-01 ROCKIT V3 SLIDECOMP I Ol RELEASE TO ESDE<FORMAr IEco nasal cmax;� 2 53-100-010 LAG SCREW,5/164'.THREAD 3",EPDM BACKED 1 C WASHER D D 4.00 1 [101.6] B B 2 i THIRD ANGLE PROJECTION DRAW"6LPRRAD a 2111 z D Ps w,I21 p f` w"I rD wr Sr—zozl ns/ A _ INTERPRET DIM AND TOLERANCE INNOVATIVE YOY/fflNetYEfWE DO NOT SCALE DRAWING PERASMEYI4.5[M]-1009 FEOFEIETARY AND CONFIDENTIAL DIMENSIONS TOLERANCES ARE IN: RI COMP SLIDE AL BLK INCHES. MILLIMETERS 1.PACKAGE PER"2011013-PCK xx:./-,Ow I x:+/.75Ol 3 Re,_ )RI COMP SLIDE AL BLK 50-PACK INST.) 'XX:-'-'010 .xx:+/-.25 D A ANGLES:+/-V 5<ALE:fa 61 5 q k G F=1 > EcoFasteni 0 INSTALLATION GUIDE For SYSTEM COMPONENTS 1 . GF-1 Flashing: All flashing options come with a pre-installed integrated EPDM grommet and one bonded stainless steel EPDM washer. Flashing are available in three options: 1 . 8 x 12" .032 gauge galvalume with mill or black (kynar painted) finish. 2. 8 x 10" .032 gauge galvalume with black (kynar painted) finish. 3. 8 x 12" .032 gauge aluminum with black (kynar painted) finish. 2. Aluminum Compression Bracket: Compatible with a variety of EcoFasten compression brackets. EcoFastenF ,. compression brackets are made out 6000 series aluminum with options available for mill or black finishes depending on the bracket. 3. Recommended Fasteners 5/16"x4" lag bolts. 3" option also available. 4. Recommended Sealant: 'n 1 ,R aj5 If required by roof manufacturer, sealant shall be roof manufacturer approved. CL DELIVERY / STORAGE / HANDLING Inspect material upon delivery. Notify manufacturer within 24 hours of any missing or defective items. Keep material dry, covered and off the ground until installed. . , 4. G F=1 teni INSTALLATION GUIDE For Installers. By InstaLters. FLORIDA PRODUCT APPROVAL Approved for any combination of 8"x12" GF-1 flashing with the ClickFit L-foot & Lag Screw. PATENTS Visit www.efpatents.com for patent information. DESIGN REQUIREMENTS 1 . Bracket spacing to be recommended by project engineer. 2. It is important to design new structures or assess existing structures to make sure they withstand retained loads. EXAMINATION >4 1 . Substrate: Inspect structure on which brackets are to be installed and verify ` r that it will withstand any additional loading that may be incurred. 2. Notify General Contractor of any deficiencies before installing EcoFasten Solar brackets. 3. Verify that roofing material has been installed correctly prior to installing ' , solar attachment bracket. INSTALLATION Comply with architectural drawings and project engineer's recommendation for ' location of system. Comply with Manufacturer's written installation instructions for installation and layout. EcoF'astenh 4141 W. VAN BUREN ST, SUITE 2, PHOENIX AZ 85009 An Esdec Solar Group Company 1 - 8 7 7 - 8 5 9 - 3 9 4 7 1 INFO @ E C O F A S T E N S O L A R. C O M