Plans AERIAL SITE VIEW JURISDICTION CODES AND STANDARDS ..`� „ ', • GOVERNING CODES ;• „ ' "#- �. `" I. ALL WORK SHALL COMPLY WITH: i 2021 OREGON ELECTRICAL SPECIALTY CODE(OESC) ION 2019 OREGON STRUCTURAL SPECIALTY CODE(OSSC) 2021 OREGON RESIDENTIAL SPECIALTY CODE(ORSC) 2018 INTERNATIONAL FIRE CODE(IFC) RECEIVED 2021 OREGON PLUMBING SPECIALTY CODE AND ALL STATE AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. AUG I I(; 2022 CONFIDENTIAL-THE INFORMATION HEREI14 F AUU ,.-. ,''` zrK,.,,c,. • - CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT ION SITE CLASSIFICATION NOTES,OSHA REGULATION CITY OF TIGARD DEVELOPER,LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO ' OCCUPANCY CLASS. SFR BUILDING DIVISION CONSTRUCTION CLASS: V-B OTHERS OUTSIDE RECIPIENTS - ORGANIZATION, EXCEPT IN CONNECTION ZONING TYPE: RESIDENTIAL WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE r, ">".:^ ._" -- '^' •' - I. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. WRITTEN PERMISSION OF ION DEVELOPERLLC. Z THIS PROJECT HAS BEEN REVIEWED AND WILL NOT DIRECT CONCENTRATED SOLAR RADIATION OR GLARE ONTO NEARBY PROPERTIES OR ROADWAYS. 3. FOR PROJECTS SUBMITTED FOR PRESCRIPTIVE REVIEW,ROOF ATTACHMENTS SHALL BE SPACED NO GREATER THAN 24"ON CENTER IN ANY DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE,HIP,EAVE,OR RIDGE OSSC ' 3111.3.5.3 ITEM 3.2 NABCEP ELECTRICAL CRITERIA,NOTES Approved plans CERTIFIED " TEMPERATURE SOURCE: ASHRAE PV INSTALLATION `'r "_ - WEATHER STATION: PORTLAND HILLSBORO Shall be on -©b site. EXTREME MIN. TEMPERATURE: -8 PROFESSIONAL ASHRAE 0.4%HIGH TEMP. 37 c� SCOTT A GURNEY � #PV-0117719-015866 I. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. r' ION DEVELOPER LLC .. TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED)IN 4801 N UNIVERSITY AVE #900 PROVO,U ` ACCORDANCE A1NCE WIITHDNEC SIO 14(DBON ALL ELECTRICAL � - C ) 84604 °;- MCI- 3. PV MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. .. ,.. 888.781.7074 „• _, '_. 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. DAVID STANLEY CONRAD - 5. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL C-ELECTRICAL CONTRACTOR � f BE PROVIDED AS PER SECTION(NEC 110.26]. LIABILITY 01524 - a The City of Tigard and its STRUCTURAL CRITERIA,NOTES employees shall not be DESIGN LOAD STANDARD: ASCE 7-16 WIND EXPOSURE CATEGORY: B responsible for discrepancies WIND SPEED(3-SEC GUST): 96 MPH which may appear herein. o GROUND SNOW LOAD: 25 PSF ' - DESIGN ROOF SNOW LOAD: 25 PSF LL.1 N SEISMIC DESIGN CATEGORY: D Q >_ N ISM ._ �',.`y.+ SEISMIC RISK FACTOR: 11 - - Q Cf) r _ (V CITY OF TIGARD o w CON REVIEWED FOR CODE COMPLIANCE c Q w N J v OFFICE COPY Approved: [ z � v o � 0- � OTC: [ ] u) U Cn z a " � Pcrinit r-,fSZS z w v> w � " 0 = � m `nom M1 Address: 0 o Y m o o LL CL 0 z Suite — o o <n w � SCOPE OF WORK SHEET LIST By: Date: Q ZZ o `—�' v v DRAWING BY INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM G-I COVER SHEET ENPHASE ENERGY V-2 SITE PLAN (AD. LIB) 5.7 KW DC & 4.35 KW AC PHOTOVOLTAIC SOLAR ARRAY S-3 ROOF PLAN �p PRO F�s DATE S-4 STRUCTURAL DETAILS VALIDITY OF PERMIT ��\����G �EF�si09 23-JUL-22 S-5 STRUCTURAL CALCULATIONS & NOTES THE ISSUANCE OF A PERMIT PROJFCT ID I V MODULES: (15) SILFAB SOLAR SIL-380 HC 20211101 E-6 ELECTRICAL DETAILS (LINE DIAGRAM) BASED ON CONSTRUCTION 9 950P 007FOO INVERTER(S): (15) ENPHASE 107PLUS-72-2-US E-7 ELECTRICAL CALCULATIONS & NOTES DOCUMENTS AND OTHER E-8 ELECTRICAL LOAD CALCULATIONS (AD. LIB) DATA SHALL NOT PREVENT OREGON SHEET NAME ROOF TYPE: COMPOSITION SHINGLE - I LAYER(S) E-9 ELECTRICAL LABELS & LOCATIONS THE CODE OFFICIAL FROM `�qN Otis COVER SHEET PV MOUNTING HARDWARE: ECOFASTEN CLICKFIT E-10 ELECTRICAL DIRECTORY PLACARD (AD. LIB) REQUIRING THE CORRECTION '9L 11 2 ky 07/26/2022 OF ERRORS.ORSC 105.4 qN R0* SHEET NUMBER REVIsoN EXPIRES:12/31/24 G-I 0 " (JF� N ION -C CONFIDENTIAL-THE INFORMATION HERE114 O Sc) \ CONTAINED SHALL NOT BE USED FOR THE �c�Lt� FRS BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF ION DEVELOPER LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL i �j. SCOTT A. GURNEY #PV-0117719-015866 ION DEVELOPER,LLC 4801 N UNIVERSITY AVE#900 PROVO.U 84604 C�J 888.781.7074 Y-2" DAVID STANLEY CONRAD ) C-ELECTRICAL CONTRACTOR C C1524 c 0 0 C' O c _ C LL N Q > O N 0 _ N G NO L1J co N < Z r� W) r-- ad Q LU N -i (n U O_ QS Z Q Y F— � U LLLJ 0 J O m Q O w c.D 0 LL 1 cO O = w m O �K m O Q = Lj PROFESS w c/) Q w Y �5 �GINfF /O OD Lo 9 950P DRAWING BY ENPHASE ENERGY OREGON cv DATE 9�q�V 07/26/2022 23-JUS-22 RO PROJECT ID EXPIRES:12/31/24 007F00 SHEET NAME N SITE PLAN SCALE: 1/8" = I'-0" SHEET NUMBER REVISON V-2 0' 2' 4' 8' 16' -2 0 SITE NOTES: 1. FOR PROJECTS HILR EW, ROOF ATTACHMENTS SHALL SPI PTIVE REVIEW, ACED NO GR�SM�Ro GREATER THAN 24" ON CENTER IN ANY DIRECTION V��S� E ION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, HIP, sp��NpF ,�pM EAVE, OR RIDGE OSSC 3111.3.5.3 ITEM 3.2 ♦ CONFIDENTIAL-THE INFORMATION HEREI CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF ION DEVELOPER LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL J SCOTT + S��J #PV017719 015866 + ION DEVELOPER,LLC ++ 4801 N UNIVERSITY AVE#900 PROVO,U Q + G 84604 + 888.781.7074 + + G DAVID STANLEY CONRAD + O C-ELECTRICAL CONTRACTOR ++ C C1524 + C + 0 + C + + c 0 0 G W N Q O N O Lu 0 N Q Q 0 N U RSI °� f--- Of � co :DH W 0 U O' J 00 of i O Q = � Z Q (n U J C3 PROFFS o z � o o W G INC F�`S/p9 o Z m D Q Q = 0 EL 0 9 950P f z Q � a w OREGON-, ) v v F V, DRAWING BY qROw� q� N 11' \0 <cy 07/26/2022 ENPHASE ENERGY N ' SCALE: 1/8" = 1'-0" EXPIRES:12/31/24 DATE 23-JUL-22 0' 2 4' 8' 16' SYSTEM LEGEND (N) (N> O ROOF SECTION ROOF PV MODULE PROJECT ID (N) PV COMBINER PANEL ADX (N) JUNCTION BOX spy SUNEYE LOCATION SECTION QTY AZIMUTH PITCH TSRF 007F00 CRITERIA AND RSI 15 155 18 90% (E) (E) UTILITY METER / (N) (N) PV LOAD CENTER (N) (N) AC DISCONNECT FIRE SETBACK SPECIFICATIONS SHEET NAME M MAIN SERVICE PANEL Lc nco (VISIBLE-OPEN LOCKABLE LABELED DISCONNECT) N ROOF PLAN MAIN (E) MAIN SERVICE PANEL PVAI (N) PV PRODUCTION DCAC (N) MICROINVERTER METER (N) PV MODULE SHEET NUMBER REVISON Sue (E) SUBPANEL (N) (M DC-DC / STRING DCD (N)DC DISCONNECT S-3 0 INVERTER RACKING INSTALLATION SCHEDULE AND STRUCTURAL CRITERIA PV MODULE PV RACKING SPAN AREA TAG SPAN PV MOUNTING RAIL RACKING: ECOFASTEN CLICKFIT RAIL -PORTRAIT-MODULE ORIENTATION ION PORTRAIT RACKING TYPE: RAIL X-SPACING P-XI 48 IN. O.C. MAX. W ORIENTATION STANDOFF: CLICKFIT L-FOOT X-CANTILEAVER P-X2 16 IN. MAX. STANDOFF TYPE: L-FOOT&FLASHING Y-SPACING P-Yl 37.4 IN. MIN. -45.3 IN. MAX. 71 5/16"X 3-1/2"ZINC PLATED PV ARRAY DETAIL, FRONT VIEW P-X2 P-XI FASTENER: STEEL LAG SCREW Y-CANTILEAVER P-Y2 12.1 IN. MIN. - 16 IN. MAX. CONFIDENTIAL-THE INFORMATION HEREI SCALE: 3/8" = '-O" LANDSCAPE CONTAINED SHALL NOT BE USED FOR THE ORIENTATION BENEFIT OF ANYONE EXCEPT ION STRUCTURAL RAIL LANDSCAPE MODULE ORIENTATION DEVELOPER,LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO ROOF TYPE: COMPOSITION SHINGLE X-SPACING L-XI 48 IN. O.C. MAX. OTHERS OUTSIDE RECIPIENTS ROOF SHEATHING TYPE: 1/2"PLYWOOD X-CANTILEAVER L-X2 16 IN. MAX. T�—1 -X2 L-XI ORGANIZATION,EXCEPT IN CONNECTION STRUCTURE TYPE: MANUFACTURED WOOD TRUSS Y-SPACING L-YI 21.1 IN. MIN. -25.1 IN. MAX. WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE RAFTER SIZE: 2x4 Y-CANTILEAVER L-Y2 7.9 IN. MIN. -9.8 IN. MAX. PORTRAIT WRITTEN PERMISSION OF ION DEVELOPER RAFTER SPACING: 24 LLC. ORIENTATION ARRAY PARAMETERS TOTAL ROOF AREA(SQ. FT.) 1200.4 P-Y2 NABCEP TOTAL PV MODULE AREA(SQ. FT.) 295.5 LANDSCAPE PV MODULE ROOF COVERAGE 25% L-Y2 CERTIFIED ORIENTATION PV INSTALLATION P-YI PROFESSIONAL SCOTT A. GURNEY -- // #PV-0117719-015866 PV ARRAY DETAIL, SIDE VIEW ION DEVELOPER,LLC SCALE: 3/8" = I'-0" A 4801 N UNIVERSITY AVE#900 PROVO,U 84604 S-4 888.781.7074 DAVID STANLEY CONRAD L-YI RACKING ATTACHMENTS TO BE STAGGERED BY SHIFTING EACH C-ELECTRICAL CONTRACTOR SUBSEQUENT ROW OF ATTACHMENTS ONE RAFTER OVER C1524 TO DISTRIBUTE LOAD ACROSS ALL FRAMING MEMBERS UNDER PV ARRAY. CD w N Q > O N PV MODULE _ No w 00 N zQ Co ') r? N 00 H � n J ~ UJ (n CLICKFIT RAIL o Q = � C/) z a Q p W CD N w ho 6" If CLICKFIT L-FOOT 0 o m Q z zo o -1 w o -a Fn (E) COMP SHINGLE 0 _ ^ ROOF MEMBRANE N -) �- DRAWING BY COMP SHINGLE FLASHING ENPHASE ENERGY 22" MIN. ����,D PROFESS DATE 23-JUL-22 DEPTH 5/16" ZINC PLATED STEEL c, GiN /� LAG SCREW WITH 2-1/2" 4,�� <, f F� MIN. EMBEDMENT IN TO 9 950P r PROJECT 1D (E) ROOF RAFTER 007FOO OREGON �1 STANDOFF DETAIL ✓ SHEET NAME H SCALE: 3" - I'-0" ,q qH 11, 20ti q07/26/2022 STRUCTURAL DETAILS ROw�� � N SHEET NUMBER REVISON EXPIRES:12/31/24 S-4 0 PV SYSTEM STRUCTURAL SPECIFICATIONS AND CALCULATIONS PV SYSTEM EQUIPMENT SPECIFICATIONS DESIGN LOCATION AND SITE SPECIFICATIONS GRAVITY LOAD /FRAMING CALCULATIONS MODULE MANUFACTURER /TYPE SILFAB SOLAR SIL-380 HC 20211101 JURISDICTION DEAD LOAD(PSF) RSI ION SOLAR MODULE WEIGHT(LBS) 43 CITY OF TIGARD ROOF MEMBRANE COMPOSITION 4.0 SOLAR MODULE LENGTH (IN.) 69.4 STATE OREGON SHINGLE SOLAR MODULE WIDTH (IN.) 40.8 ADOPTED LOAD STANDARD ASCE 7-16 SHEATHING 1/2"PLYWOOD 1.7 SOLAR MODULE AREA(SO. FT) 19.7 OCCUPANCY /RISK CATEGORY 11 r PV RACKING ECOFASTEN CLICKFIT BASIC WIND SPEED(MPH(3-SEC GUST)) 96 CONFIDENTIAL-THE INFORMATION HERE CONTAINED SHALL NOT BE USED FOR TH PV RACKING TYPE RAIL WIND EXPOSURE CATEGORY B MANUFACTURED BENEFIT OF ANYONE EXCEPT ION PV ROOF ATTACHMENT CLICKFIT L-FOOT GROUND SNOW LOAD(PSF)(PG) 25 WOOD TRUSS- TOP DEVELOPER,LLC NOR SHALL IT BE 5/16"X 3-1/2"ZINC PLATED STEEL LAG FRAMING CHORD 2X4 @ 24 IN. 1.0 DISCLOSED IN WHOLE OR IN PART TO PV ROOF ATTACHMENT FASTENER SCREW BASE ELEVATION (FT) 153 O.C. -DF#2 @5.8 OTHERS OUTSIDE RECIPIENTS FT. MAX SPAN ORGANIZATION,EXCEPT IN CONNECTION RACKING DEAD LOAD(PSF) 0.8 WITH THE SALE AND USE OF THE SOLAR MODULE DEAD LOAD (PSF) 2.18 DESIGNED ROOF SNOW LOAD CALCULATIONS ASCE 7-16(C&C) RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF ION DEVELOPER TOTAL PV ARRAY DEAD LOAD (PSF) 2.98 SLOPED ROOF SNOW LOAD(PSF) EQN. 7.4-1 LLC. =Ps =(Cs)(0.7)(CE)(CT)(IS)(PG) TOTAL ROOF DEAD LOAD(PSF) 6.7 PV SYSTEM STRUCTURAL SPECIFICATIONS EXPOSURE FACTOR (CE) = 1.0 TABLE 7.3-1 ADJUSTED TO SLOPED ROOF(PSF) 7.1 STRUCTURE TYPE-ROOF SHAPE INHABITED-GABLE /FLAT ROOF THERMAL FACTOR (CT) = 1.0 TABLE 7.3-2 NABCEP MIN. ROOF SLOPE(DEG.) 18 IMPORTANCE FACTOR(Is) = 1.0 TABLE 1.5-2 PV ARRAY ADJ. TO ROOF SLOPE(PSF) 3.1 MEAN ROOF HEIGHT(FT.) 20 SLOPE FACTOR(Cs) = 1.0 FIG. 7.4-1 ROOF LIVE LOAD< ROOF SNOW LOAD (PSF) 25.0 CERTIFIED PORTRAIT ATT. SPACING(IN. O.C.) 48 Ps(PSF) = 25 OK TOTAL LOAD(PSF) 35.2 PV INSTALLATION LANDSCAPE ATT. SPACING (IN. O.C.) 48 PROFESSIONAL #OF ATTACHMENT POINTS 60 RAFTER/ TOP CHORD MEMBER PROPERITES DF#2 -2x4 MAX. POINT LOAD(LBS/ATT.) 9.2 SECTION MODULUS(S)(IN"3) 3.06 S. SCOTT A. GURNEY 7719-015866 MAX. TOTAL PV DEAD LOAD TO RAFTER(LBS) 18.3 MOMENT OF INERTIA(1)(IN"4) 5.36 TOTAL LOAD ON MEMBER(W)(PLF) 70.4 ION DEVELOPER,LLC 4801 N UNIVERSITY AVE#900 PROVO,U DESIGN WIND PRESSURE AND CONNECTION UPLIFT CALCULATIONS ASCE 7-16(C&C) MAX. MEMBER SPAN(L)(FT) 5.8 84604 DESIGN WIND PRESSURE(PSF) =P=OH(GCP)(YE)(YA) EQN. 29.4-7 MODULUS OF ELASTICITY(E)(PSI) 1600000 888.781.7074 VELOCITY PRESSURE(PSF) =OH =0.00256(KH)(KZT)(KD)(KE)(V"2) EQN. 26.10-1 SHEAR(Fv)(PSI) 180 TERRAIN EXPO. CONSTANT(A) = 7 TABLE 26.11-1 ARRAY EDGE FACTOR(YE)= I TABLE 26.13-1 AREA(A)(IN"2) 5.25 DAVID STANLEY CONRAD TERRAIN EXPO. CONSTANT(ZG)(FT)= 1200 TABLE 26.11-1 GROUND ELEVATION FACTOR(KE)= 0.99 FIG. 29.4-8 C-ELECTRICAL CONTRACTOR VP EXPOSURE COEFF.(KH)= 0.70 EQN. C26.10-1 EQN. 26.10-1 MAX BENDING STRESS CHECK (FB)(CD)(CF)(CR) CI524 TOPOGRAPHIC FACTOR(KZT) = 1.0 EQN. 26.8-1 QH(PSF)= 13.96 BENDING (FB)(PSI) 900 WIND DIRECTIONALITY FACTOR(KD)= 0.85 TABLE 26.6-1 LOAD DURATION FACTOR(CD) 1.15 SIZE FACTOR(CF) 1.50 UPLIFT DOWNWARD REPETITIVE MEMBER FACTOR(CR) 1.15 GABLE ROOF 7°< 0<-20° ZONE I ZONE 2R ZONE 2E ALL ZONES FIGURE 30.3-2B ALLOWABLE BENDING STRESS(PSI) 1785.4 p RAIL -PORTRAIT MODULE ORIENTATION 48 IN. O.C. 48 IN. O.C. 48 IN. O.C. 48 IN. O.C. - SOLAR PANEL PRESSURE EQ. FACTOR(YA) = 0.80 0.80 0.80 0.80 ACTUAL BENDING STRESS(PSI) =(wL"2)/(8(S)) 1159.4 Q > o EXTERNAL PRESSURE COEFF. (GCP)= -2.0 -3.0 -3.6 0.7 65% OK < Of N ASD PRESSURE (0.6P)(PSF)= -13.40 -20.10 -24.12 13.03 = m = TRIBUTARY AREA(SQ. FT)= 11.6 11.6 8.7 MAX DEFLECTION CHECK- TOTAL LOAD UNIFORM DISTRIBUTED N LU o N U MAX. UPLIFT(0.6D+0.6P)(LBS) = -134.3 -211.8 -193.7 ALLOWABLE DEFLECTION L/ 180 Z y: ND Q 0.387 IN. CO Q LU (\J J RAIL LANDSCAPE MODULE ORIENTATION 48 IN. O.C. 48 IN. O.C. 48 IN. O.C. 48 IN. O.C. ACTUAL MAX DEFLECTION (W)(L)"4 / 185(E)(I) W N U J u) SOLAR PANEL PRESSURE EQ. FACTOR(YA) = 0.80 0.80 0.80 0.80 0.087 IN. Z CO [if m 3�: EXTERNAL PRESSURE COEFF. (GCP)= -2.0 -3.0 -3.6 0.7 22% OK O LU < U Z Q L ASD PRESSURE (0.6P)(PSF)= -13.40 -20.10 -24.12 13.03 MAX DEFLECTION CHECK-LIVE LOAD Q O Lu 7: 00 (D) w TRIBUTARY AREA(SQ. FT)= 6.80 6.80 5.10 ALLOWABLE DEFLECTION L / 240 � O O = LU� m < MAX. UPLIFT(0.6D+0.6P)(LBS) = -79.0 -124.5 -113.9 0.29 IN. O :L M O Q = U ACTUAL MAX DEFLECTION (W)(L)"4 / 185(E)(1) z Z O c J m o ROOF ATTACHMENT FASTENER CHECK NDS 12.2 0.074 IN. W p o Q in W Y CLICKFIT L-FOOT-5/16"X 3-1/2"ZINC PLATED H- Cl�O - O _ STEEL LAG SCREW MANUFACTURER MAX. UPLIFT CAPACITY=359.6 LBS 26% OK 0Lo LAG SCREW WITHDRAWAL DESIGN VALUE(LBS)=W = I800(G"3/2)(D"3/4) 12.2.1 MAX SHEAR CHECK ROOF ATTACHMENT FASTENER(D) = 5/16 IN. LAG SCREW LUMBER SPECIFIC GRAVITY(G)= 0.5 TABLE 2.3.2 ALLOWABLE SHEAR Fv(A) DRAWING BY FASTENER QTY PER ATTACHMENT = I LOAD DURATION FACTOR(CD)= 1.6 TABLE 12.3.3A 945 LBS. ENPHASE ENERGY FASTENER EMBEDMENT DEPTH(IN.) = 2.5 PRYING COEFFICIENT = 1.4 ACTUAL MAX SHEAR (w)(0/2 WITHDRAWAL DESIGN VALUE(W)(LBS/ IN.)= 266.0 �p PRO FE'S. 204 LBS. DATE LAG SCREW WITHDRAWL CAPACITY(LBS) = 760.0 \�` GIN 22% OK 23-JUL-22 MAX. ATT. WITHDRAWAL CAPACITY(LBS)= 359.6 > 211.8 MAX UPLIFT DEMAND(LBS) OK 98950P PROJECT ID 007F00 OREGON SHEET NAME `�qiy 11 20`ti�y STRUCTURAL CALCS qN RO`N�'�` 07/26/2022 SHEET NUMBER REVISON EXPIRES:12/31/24 S-5 0 CONDUCTOR AND RACEWAY SCHEDULE TAG QTY SIZE-# TYPE DESIGNATOR I/V TAG OTY SIZE-# TYPE DESIGNATOR I/V TAG QTY SIZE-# TYPE DESIGNATOR I/V TAG QTY SIZE-# TYPE DESIGNATOR I/V 10 00 10 AWG THHN/THWN,CU. BLACK(LI) IB.2 A AC(MAX) 3 (2) 8 AWG THHN/THWN,CU. BLACK(LI) 15.7 A AC(MAX) 2 (1) 8 AWG 2C,NM-B W/G,CU. (LI,L2,EGC) 15.7 A AC(MAX) 1 (1) 12 AWG 2C,TC-ER,CU. (LI,L2) 15.7 A AC(MAX) (1) 10 AWG THHN/THWN,CU. RED(1-2) 240 V AC (2) 8 AWG THHN/THWN,CU. RED(L2) 240 V AC FREE AIR 240 V AC (1) 6 AWG SOLID BARE CU. (EGC) 240 V AC (1) 10 AWG THHN /THWN,CU. WHITE(N) (1) 8 AWG THHN /THWN,CU. GREEN(EGC) (1) 3/4 IN. EMT OR FREE AIR (RACEWAY) ION (1) 10 AWG THHN /THWN,CU. GREEN(EGC) (1) 3/4 IN. EMT (RACEWAY) (1) 3/41N. EMT (RACEWAY) EXTERIOR EXTERIOR INTERIOR EXTERIOR II (1) 6 AWG THHN/THWN,CU. BLACK(LI) 18.2 A AC(MAX) (1) 6 AWG THHN/THWN,CU. RED(1-2) 240 V AC w (1) 6 AWG THHN/THWN,CU. WHITE(N) CONFIDENTIAL-THE INFORMATION HEREI (1) 6 AWG THHN /THAN,CU. GREEN(GEC) CONTAINED SHALL NOT BE USED FOR TH (1) 3/4 IN. PVC SCH. 40 (RACEWAY) EXTERIOR BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE (I5)SILFAB SOLAR SIL-380 HC 20211101 PV MODULE(S) DISCLOSED IN WHOLE OR IN PART TO ELECTRICAL LINE DIAGRAM UL 1703 LISTED OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION (E)IOOA MAIN SERVICE PANEL (15)ENPHASE 107PLUS-72-2-US MICROINVERTER(S)[240V] WITH THE SALE AND USE OF THE MULTIPLE MAIN DISCONNECTS SUPPLY-SIDE SOURCE CONNECTION (N)ENPHASE IQ COMBINER 3 (N)JUNCTION BOX UL 1741 LISTED RESPECTIVE EQUIPMENT,WITHOUT THE (E)UTILITY FEWER THAN 6 HANDLES MAIN SERVICE PANEL SERVICE (PV CIRCUITS ONLY) (OPTIONAL-FOR WRITTEN PERMISSION OF ION DEVELOPER METER (NEC 230.71) ENTRANCE CONDUCTOR TAP CONDUCTOR SPLICE) (N)JUNCTION BOX LLC. (NEC 230.82,NEC 705,NEC 230.46) (N)PV AC DISCONNECT (N)20A/2Pu A A F Li A - (q 60A,24OV,2P,FUSED CIRCUIT LOCKABLE,VISIBLE OPEN E� OF L NABCEP SERVICE RATED E MODULES INTEGRATED CERTIFIED (E7 OAOS 15A/2P MAX TO IQ ENVOY PV INSTALLATION E o— GATEWAY 2 1 PROFESSIONAL (N)25A (N)JUNCTION BOX 120/240 VAC IFFUSES �j.��y SCOTT A. GURNEY 60HZ E)LOADS (N)15A/2P _ (1) _ f77 — — #PV-0117719-015866 SINGLE PHASE �o- c' -- CIRCUIT -- - ION DEVELOPER,LLC UTILITY ti `� - OF 2 SERVICE N -- _ MODULES 4801 N UNIVERSITY AVE#900 PROVO,U ':.. 84604 888.781.7074 G II 10 DAVID STANLEY CONRAD SPL¢pRSI a E 2 C-ELECTRICAL CONTRACTOR (N)GEC PERMITTED TO C1524 eec RUN SEPARATELY OUTSIDE RACEWAY IF SOLID BARE AND NOT EXPOSED TO PHYSICAL (E)GROUNDING DAMAGE. ELECTRODE [NEC 250.64(B)] SYSTEM O Lu N Q O N Q U c77 O w °0 N Q Q C/) N U C0 LLI J ~ W (n U 0, J o_ a = �< r- z H LLl D U w O JO Lo ELECTRICAL LINE DIAGRAM NOTES � (D o = W m "' � O �L m O Q = Z Z OJ a o w Q Q cn LU Y o p U n c/) H Lo DRAWING BY ENPHASE ENERGY DATE 23—JUL-22 PROJECT ID 007F00 SHEET NAME ELEC. LINE DIAG. SHEET NUMBER REVISON E-6 0 PV SYSTEM ELECTRICAL SPECIFCATIONS AND CALCULATIONS DESIGN LOCATION AND TEMPERATURES RACEWAY / CONDUCTOR CALCULATIONS TEMPERATURE DATA SOURCE ASHRAE MICROINV. TO JUNCTION BOX (1) ION STATE OREGON MAX INVERTER OUTPUT CIRCUIT CURRENT = 15.7 A AC JURISDICTION CITY OF TIGARD MAX CURRENT X125%= 20.0 A AC WEATHER STATION PORTLAND HILLSBORO PER NEC 690.8(B)(1)(W/OUT CORRECTION FACTORS) ASHRAE EXTREME LOW TEMP (°C) -8 CONDUCTOR SIZE / INSULATION / TYPE = 12 AWG 2C, TC-ER, CU. CONFIDENTIAL-THE INFORMATION HEREI CONTAINED SHALL NOT BE USED FOR TH ASHRAE 0.4% HIGH TEMP (°C) 37 CONDUCTOR AMP. RATING @ 90°C = 30 A BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE DESIGNED MAX. SYSTEM VDROP / VRISE 2.00% AMB. TEMP. AMP. CORRECTION = NOT APPLIED DISCLOSED IN WHOLE OR IN PART TO ADJUSTED AMPACITY COMPLIANCE (A) = 30 > 20.0 OK OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION PV MODULE SPECIFICATIONS SILFAB SOLAR SIL-380 HC 20211101 RACEWAY SIZE / TYPE = 3/4 IN. EMT OR FREE AIR WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE RATED POWER (PMAX) (W) 380 CROSS-SECTIONAL AREA OF CONDUCTOR(S) / CABLE(S)(IN."2) = 0.142 IN.2 WRITTEN PERMISSION of ION DEVELOPER MAXIMUM POWER VOLTAGE (VMP) 35.32 CROSS-SECTIONAL AREA OF RACEWAY(IN."2) = 0.533 IN.2 LLC. MAXIMUM POWER CURRENT (IMP) 10.77 % ALLOWABLE RACEWAY FILL (NEC CHAPTER 9, TABLE 1) = 53% > 27% OK OPEN CIRCUIT VOLTAGE (VOC) 42.17 NABCEP SHORT CIRCUIT CURRENT (ISC) 11.36 JUNCTION BOX TO JUNCTION BOX (2) CERTIFIED PMP/VMP TEMP. COEFFICIENT -0.36 MAX INVERTER OUTPUT CIRCUIT CURRENT = 15.7 A AC VOC TEMP. COEFFICIENT -0.28 MAX CURRENT X125% = 20 A AC PV INSTALLATION SERIES FUSE RATING 20 PER NEC 690.8(B)(1)(W/OUT CORRECTION FACTORS) PROFESSIONAL ADJ. MODULE VOC @ ASHRAE LOW TEMP 46.1 CONDUCTOR SIZE / INSULATION / TYPE = 8 AWG 2C, NM-B W/G, CU. S•� SCOTT 7 GURNEY #PV-0117719-015866 ADJ. MODULE VMP @ ASHRAE 2% AVG. HIGH TEMP 29.7 CONDUCTOR AMP. RATING @60°C = 40 A ION DEVELOPER,LLC # OF CONDUCTORS IN RACEWAY CORRECTION = NOT APPLIED 4801 N UNIVERSITY AVE#900 PROVO,U 84604 INVERTER SPECIFICATIONS ENPHASE IQ7PLUS-72-2-US AMB. TEMP. AMP. CORRECTION = NOT APPLIED 888.781.7074 TYPE MICROINVERTER ADJUSTED AMPACITY COMPLIANCE (A) = 40 > 20.0 OK MAX. OR RECOMMENDED MODULE POWER (W) 440 RACEWAY SIZE / TYPE = FREE AIR DAVID STANLEY CONRAD C-ELECTRICAL CONTRACTOR MAXIMUM INPUT DC OPEN-CIRCUIT VOLTAGE (VOC) 60 01524 MINIMUM START VOLTAGE (V) 22 MAXIMUM START VOLTAGE(V) 60 MAXIMUM INPUT CURRENT (ISC) (A) 15 CEC PEAK OUTPUT POWER (W) 290 JUNCTION BOX TO COMBINER BOX (3) MAX. CONTINUOUS OUTPUT CURRENT (A) 1.21 MAX INVERTER OUTPUT CIRCUIT CURRENT = 15.7 A AC NOMINAL (L-L) OUTPUT VOLTAGE 240 a j o CEC WEIGHTED EFFICIENCY (%) 97.0% PER NEC 690.8(B)(2)(WITH CORRECTION FACTORS) N CONDUCTOR SIZE / INSULATION / TYPE = 8 AWG THHN / THWN, CU. v o � SYSTEM ELECTRICAL SPECIFICATIONS CIR I CIR 2 CONDUCTOR AMP. RATING @60°C = 50 A 0 w c N c- N < NUMBER OF MODULES PER CIRCUIT 13 2 # OF CONDUCTORS IN RACEWAY CORRECTION = 0.8 ) Q cn N �0 rLU U DC POWER RATING PER CIRCUIT (STC)(W DC) 4940 760 AMB. TEMP. AMP. CORRECTION = 0.88 °� 1- � TOTAL MODULE QUANTITY 15 PV MODULES ADJUSTED AMPACITY COMPLIANCE (A) = 35.2 > 15.7 OK Z (5 L v STC DC POWER RATING OF ARRAY 570OW DC RACEWAY SIZE / TYPE = 3/4 IN. EMT LJ can v w zo Q � INVERTER OUTPUT CIRCUIT CURRENT(A AC) 15.73 2.42 CROSS-SECTIONAL AREA OF CONDUCTOR(S) / CABLE(S)(IN."2) = 0.183 IN.'2 a o w 37 0 o) Lu 125% INVERTER OUTPUT CIRCUIT CURRENT(A AC) 19.66 3.03 CROSS-SECTIONAL AREA OF RACEWAY(IN."2) = 0.533 IN.^2 O o � m Q CIRCUIT OCPD RATING (A) 20 15 % ALLOWABLE RACEWAY FILL (NEC CHAPTER 9, TABLE 1) = 40% > 34% OK � Z m o o a [ o COMBINED INVERTER CONTINUOUS OUTPUT CURRENT 18.15A AC w o o Q V) w PV POWER PRODUCTION SYSTEM OCPD RATING (X125%) 25A COMBINER BOX TO MAIN PV OCPD (10) o QD_ � MAX. ARRAY STC-AC POWER (W) 435OW AC (STC) COMBINED INVERTER CONTINUOUS OUTPUT CURRENT = 18.2 A AC c ~ Lo MAX. ARRAY CEC-AC POWER (W) 5084W AC (CEC) MAX CURRENT X125% = 23.0 A AC DRAWING BY PER NEC 690.8(B)(1)(W/OUT CORRECTION FACTORS) ENPHASE ENERGY AC VOLTAGE RISE CALCULATIONS DIST (FT) COND. VRISE(V) VEND(V) %VRISE CONDUCTOR SIZE / INSULATION / TYPE = 10 AWG THHN / THWN, CU. DATE VRISE SEC. I (MICRO TO JBOX) * 28.8 12 Cu. 1.8 241.8 0.76% CONDUCTOR AMP. RATING @75°C = 35 A 23-JUL-22 VRISE SEC. 2 (JBOX TO COMBINER BOX) 95 8 CU. 2.3 242.3 0.97% # OF CONDUCTORS IN RACEWAY CORRECTION = NOT APPLIED VRISE SEC. 3 (COMBINER BOX TO P01) 10 10 Cu. 0.4 240.4 0.18% AMB. TEMP. AMP. CORRECTION = NOT APPLIED PROJECT ID TOTAL VRISE 4.6 244.6 1.91% OK ADJUSTED AMPACITY COMPLIANCE (A) = 35.0 > 23.0 OK 007F00 * 8 MICROINVERTER MAX SUB-BRANCH CIRCUIT SIZE TO COMPLY WITH VRISE CALCULATIONS. RACEWAY SIZE / TYPE = 3/4 IN. EMT CROSS-SECTIONAL AREA OF CONDUCTOR(S) / CABLE(S)(IN."2) = 0.084 IN.^2 SHEET NAME CROSS-SECTIONAL AREA OF RACEWAY(IN."2) = 0.533 IN."2 ELECTRICAL CALLS. % ALLOWABLE RACEWAY FILL (NEC CHAPTER 9, TABLE 1) = 40% > 16% ON SHEET NUMBER REVISON E-7 ELECTRICAL FIELD-APPLIED HAZARD MARKINGS ❑ AT EACH PV SYSTEM DISCONNECTING MEANS. RAPIDI, III ❑ SIGN LOCATED ON OR NO MORE THAN 3 [NEC 690.54, NEC 690.13(8)] p F FT FROM THE RAPID SHUT DOWN ( SWITCH FOP, DISCONNECT SWITCH [NEC 690.56(C)]. ION !A' SOLAR r TER NMILOPOWERATNGAC VOLTAGE 240 V SOLAR PV SYSTEM EQUIPPED © FOR BUILDINGS WITH PV SYSTEMS. TO CONFIDENTIAL-THE INFORMATION HEREI II BE LOCATED AT EACH SERVICE CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT ION © FOR PV DISCONNECTING MEANS WHERE ALL WITH RAPID SHUTDM EQUIPMENT LOCATION TO WHICH THE PV DEVELOPER,LLC NOR SHALL IT BE TERMINALS OF THE DISCONNECTING MEANS TURN WDSHUTDOM SYSTEM IS CONNECTED. [NEC DISCLOSED IN WHOLE OR IN PART TO MAY BE ENERGIZED IN THE OPEN POSITION. SWrTCHTOTHE 690.56(C)] OTHERS OUTSIDE RECIPIENTS ELECTRIC SHOCK HAZARD 'OFFP6�TIONTO ORGANIZATION,EXCEPT IN CONNECTION TERMINALS ON THE LINE AND [NEC 690.13(B), NEC 705.221 SHUT DOWIHPYGnTE►I WITH THE SALE AND USE OF THE AND REDXE SHOpcHaZnNu RESPECTIVE EQUIPMENT,WITHOUT THE LOAD SIDES MAY BE ENERGIZED r.,. IN THE OPEN POSITION - NTlAHRAY WRITTEN PERMISSION ION DEVELOPER J PERMANENT DIRECTORY TO BE LOCATED AT AT EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUTS SUPPLYING POWER TOA MAIN SERVICE EQUIPMENT DENOTING THE NABCEP 1 C LOCATION OF THE PV RAPID SHUTDOWN SYSTEM BUSBAR OR CONDUCTOR SUPPLIED FROM P��TOT � �N�SUPFU m DISCONNECTING MEANS IF SOLAR ARRAY RAPID CERTIFIED DUAL POWER SUPPLY MULTIPLE SOURCES. [NEC 705.12(C)] FROM�A� ID SOLAR RAPID SHUTDOWN SHUT DOWN DISCONNECT SWITCH IS NOT SOURCES:UTIIITYGRIDAND SxiARRAYDSHUTDOWrNaSCONNECT GROUPED AND WITHIN LINE OF SITE OF MAIN PV INSTALLATION PV SOLAR ELECTRIC SYSTEM Is LOCATED SERVICE DISCONNECTING MEANS. [NEC 705.10, PROFESSIONAL NEC 690.56(C)(1)] �j.�/�y SCOTT A. GURNEY / #PV-0117719-015866 PLACED ADJACENT TO PV SYSTEM PLUG-IN PERMANENT DIRECTORY T BE LOCATED AT ION DEVELOPER, 0 aLC SOLAR ARRAY RAPID SHUTDOWN SWITCH 4801 N UNIVERSITY AVE#900 PROVO,U TYPE BREAKER TO A BUSBAR FOR A LOAD 84604 DENOTING THE LOCATION OF THE SERVICE POWER SOURCE SIDE CONNECTION. [NEC 705.12(B)(3)(2)] POWER LIEDFR FROM NTRiminG 19 o EQUIPMENT LOCATION IF SOLAR ARRAY RAPID 888.781.7074 I suPR�o PROAi Nuv�otaTrnaurloN OUTPUT CONNECTION SHUT DOWN DISCONNECT SWITCH IS NOT ONRAD DO NOT RELOCATE THIS UnUTY DISCONNECT LOCATED GROUPED AND WITHIN LINE OF SITE OF MAIN DAVID STANLEY OVERCURRENT DEVICE SERVICE DISCONNECTING MEANS. [NEC 705.101 C-ELECTRICAL CONTRACTOR C1524 Pil E O © M © QLu N (E) o © © a < o UTILITY = _ METER (E)MAIN SERVICE PANEL COMBINER BOX ■. O W 00 N U UZQ � N u ��. °6 W -i cV J � H H r Lz — Z C7 � U � � J N � af IL z (N)PV AC DISCONNECT - O Q = z Q n S2 ~ V) U UJ O Q O 0 U cn w 0 Z O Z = W m L PV SYSTEM O � m 0 Q = U DISCONNECTS) TO U- Z O J m ° jV an PV INVERTER z Q Z OUTPUT CIRCUITS) W O Q cf) W < uu ®", Q O O �n o o GEC EGC _ DRAWING BY ENPHASE ENERGY DATE 23-JUL-22 PROJECT ID 007F00 ALL CAUTION, WARNING, OR DANGER SIGNS OR LABELS SHALL: SHEET NAME I, COMPLY WITH ANSI Z535.4-2011 STANDARDS. ELECTRICAL LABELS 2. BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN. 3. SHALL BE OF SUFFICEINT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 4. UNLESS OTHERS SPECIFIED MINIMUM TEXT HEIGHT TO BE�" (3MM). SHEET NUMBER REVISON E-9 0 IDENTIFICATION OF POWER SOURCES A PERMANENT PLAQUE OR DIRECTORY TO BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION DENOTING THE LOCATION OF EACH POWER SOURCE DISCONNECTING MEANS AND SHALL INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. FOR THE BUILDING OR STRUCTURE AND ION BE GROUPED WITH OTHER PLAQUES OR DIRECTORIES FOR OTHER ON-SITE SOURCES. ALL MARKING TO COMPLY WITH 110.21 (B). (NEC 705.10) CONFIDENTIAL-THE INFORMATION HEREI CONTAINED SHALL NOT BE USED FOR TH BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE CAUTION : MULTIPLE WRITTEN PERMISSION OF ION DEVELOPER LLC. i rZ SOURCES OF POWER . NABCEP CERTIFIED POWER TO THIS BUILDING IS SUPPLIED FROM THE PV INSTALLATION FOLLOWING SOURCES WITH DISCONNECTS LOCATED ��//PROFESSIONAL AS SHOWN: S- SCOTT A. GURNEY / #PV-0117719-015866 ION DEVELOPER,LLC W ° 4801 N UNIVERSITY AVE#900 PROVO,U _ m 84604 rym m 888.781.7074 ryDAVID STANLEY CONRAD LuLL.I 0 m C-ELECTRICAL CONTRACTOR m m C1524 (n O m Lu m m m U m o m m m PV ARRAY LU � o Z w N O Q >_ Q N (n OILL ::D _ N O O Q Z N � ^ U CC5LLJ N J E- 0' I- :D (i) Z U L U o\ Ncr_ J (N) (N) IE)C ACL M O Q ~ Z IL Q Y U - w J O — U w U 0 w n UTILITY SERVICE METER O " o � m Q • RAPID SHUTDOWN AC DISCONNECT SWITCH o Z m 0 o a CL o UTILITY SERVICE DISCONNECT Ui (o Q � w p L7 (n H gyri DRAWING BY ENPHASE ENERGY DATE 23-JUL-22 i PROJECT ID j 007F00 I I SHEET NAME ELEC. DIRECTORY j SHEET NUMBER REVISON 3 E-10 0