Report (4) Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
am the general contractor or the owner-builder
at the following address:
Site Address:
City:
Permit #:
2,07 0o
Subdivision/Lot #: 6031
and/or
Map and Tax Lot #:
To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: 6,, �_- L Date: 4�/p 12,Z
General Contractor or Owner-Builder
I:A13uiIding\Form\RISS-MoistureCon1entAcknowledgemen1_022018
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
1, ia.%,i;n ✓06 440011 am the general contractor or the owner-builder
at the following address:
Site Address: q
City:
Permit#:
"j.5 I,-Zo21 -ooh4Y
Subdivision/Lot#:
�o3f
and/or
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
The ground surface of the under-floor space is covered by a Class I vapor retarder or
other approved materials, with
Joints lapped 12 inches at seams and
Extending up the foundation walls 12 inches.
Signature: YDate: b//y/ZZ
General Contractor or Owner-Builder
1:ABui1ding\Form\RF.S-MoistureBarrierAcknowledgement_022018
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
PermitNo.: /''IsJurisdiction:
z � d
Site Address:
/7'D yg
Subdivision/Lot
and/or
Map and Tax Lot#:
By my signature below, I certify that all of the permanently installed lighting fixtures in the
above mentioned building contain high-efficacy lamps. Screw-in compact fluorescent and LED
lamps comply with this requirement. (Oregon Residential Specialty Code N 1107.2)'
Signature: EDate: 4&ryZ2,;>
Owner/General Contractor/Authorized Agent
Print Name: /&__ 1, T3,,L#10z "
' ORSC Section N 1107.2. High-efficacy lamps. All permanently installed lighting fixtures shall contain high-
efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement.
The building official shall be notified in writing at the final inspection that the permanently installed lighting fixtures
have met this requirement.
Exception: Two pennanently installed lighting fixtures are not required to have high-efficacy lamps.
I:ABui1ding\Tonus\1U?S-1lighEfficiencyLightingAcknowledgemen(_022018
Form 640S 2017
Completion Certification—Site Inspection
New Homes Program—Single Family �
�...T,n
of Oregon
To be completed by Verifier
CLEAR esult Is a Program Management Contractor for Energy Trust of Oregon,Inc.
Payment Information
Incentive Payee Company Name: Performance Insulation and Energy lis this payment redirected?: Yes
Builder or Company: I Polygon Northwest-WA Redirect to Name:
Verifier Payee Company Name:I Performance Insulation and Energy Redirect Payee Com Performance Insulation and Energy
Affordable Housing No
Solar Ready Builder Incentive: jNo Solar I1,,dyVerrfier Inc No
SRO information...
Development:13C EASTRIDGE CRESCENT TH Lot \ �� �Y.Axis ID: REM/Rate®ID:
Address:
Street Line 2 Multi-Fatuity No City: PORTLAND State: OR I Zip: 97229
Total conditioned area(sq.ft.): 1,908 House Volume: 20,079 Housing Type: I Townhouse end
Number of Stories: 4 Number of Bedrooms: 3 Foundation Type: Slab Floor
Electric Provider: Portland General Electric Gas Provider: NW Natural Gas
Solar installed I None Solar Installer Name/Company:
Blue shaded fields are required for EPS sheet
Verification Type Actual Model Equipment Details 6 Notes
Slab Perimeter Insulation R- Slab Under Insulation R-
Insulation Framed Floor R- 30.0 Secondary Framed Floor R-
Above Grade Wall Insulation R- 23 Below Grade Wall Insulation R-
Flat Ceiling Insulation R- 49.0 Vaulted Ceiling Insulation R-
Windows Windows U- 0.3 SHGC:10.3 Total window area:
Cooling Air Conditioning SEER: 0 Model#: 13ACXN030-230-26
Primary Heating System Details AFUE: 95 Brand Lennox
Type: Gas Furnace HSPF: Model#: ML196UH045XE36B-51
Primary Heat
Heating Fuel: Gas SEER:
Source Comment: COP:
Location: Attic Outdoor Unit(for heat pumps)
ECM: No Model#:
AHRI Certificate:4805339 #of Systems 1
Gallons: 66 Brand: AOSmith
Water Heater Type Heat Pump EF: 3.17 Model#: HPTU-66N 130
Water Heating Fuel Electric Location: I Garage or cps AHRI Certificate:
Ducts and Duct Location IPartial %ducts inside: Duct Leakage(CFM)@ 50Pa: ; 7�,,,y�,,,,.
Testing
Infiltration Air Changes per Hour(ACH)@ 50Pa: 15.09
Ventilation Ventilation Type HRV/ERV Model:
Supply Side-Air Cycler Airflow measured or why untestable? I Roof Termination
Appliances
Refrigerator lkwlvy, Model:
ENERGY STAR Diswasher jkWIVyr Model: IGDF51OPSR3SS
Percent High Efficacy Interior Lighting I%) Thermostat
Showerhead 1.5 GPH Showerhead 1.6 GPH IShowerheatl 1.75 GPH
Nobs: .
�� lit IlPgllil!� I��
QTY WALL B.. �N�Ui�..A't�pN
Certificate of Compliance
This document certifies that the fiberglass insulation has been installed in conformance
with the manufacturer's recommendations and requirements to provide thermal resistance value(s)of:
R-value Thickness Coverage Area
Ceilings: R-49 X New Construction
Vaults/Slopes: R-38
Walls: R-23 0 Upgrade
Blown in
Rim Joist:
Floors:
Over Garage R-39 BIBS
Crawl Vapor Barrier installed Y N Sprinkler Tenting 4 mil Poly Y _N
Loose-Fill Insulation
R-_using_bags of insulation to cover All Batts square feet of area at a thickness of 20 inches.
Owens Corning'PROPINK"L77 Loosefill Insulation
Owens Corning will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value is provided by
installing the required number ofbags ata thickness not less than the labeled minimum thickness.Installation ofthe required number of bags may yield
more than the specified minimum thickness.Failure by the installer to provide both the required bags and at least the minimum thickness will result
in lower insulation R-value.
R-VALUE IIAGS PER MAXIMUM NFT MINIMUM WEIGHT MINUMUM
1()00 SQ.FT. (ML RAGE PFR Sp.FT. THICKNESS
To obtain a No.ofbags per 1000 sq. Contents of this bag Weight per sq. 11.of' Installed iustdation
thermal resistance ft,of net area: should not cover installed instil,should should not be less
(R)of: more than:(sq. tt.) not be less than:(lbs.) than:(in.)
oo 28.0 35.8 0.895 20.00
49 22.2 45.0 0,711 16.75
44 19.7 50.7 0.631 15.00
38 16.7 59.9 0.534 1.325
30 13.0 77.0 0.410 10.50
26 11.2 89.6 0.357 9.25
22 9.4 1063 0.301 8.00
19 8.0 125.0 0.256 7.00
13 5.4 184.6 0.173 4.75
Property Address: 17049 SW Friendly Ln, Tigard, OR. 97224 Lot 31
3/31/22 Rafael Gutierrez
Date of installation Westside Drywall Inc.authorization
6/2/22
Today's Date Building Contractor's Signature
Taylor Morrison
Company/Customer Name
P.O.BOX 99'MMBAM,OR 97032•(503)620-7036•FAX(503)6244599.CCB#71044