Loading...
08-August 71 CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2022-00157 Date Issued: 08/17/2022 TIC ART) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S1070001305 Jurisdiction: Tigard Site address: 16704 SW COLORADO LN Subdivision: SOUTH RIVER TERRACE Lot: Project: South River Terrace, Lot 43 Project Description: New detached dwelling. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 1353 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 3 Second: 1852 sf Garage: 439 sf Front: 12 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 3205 sf Value: $441,020.82 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 100 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add9 500 sf: 6 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 3205 Owner: Contractor: TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $28,273.57 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc _nn111Mn thrni inh CIA 9-nM-. on ,mat/nht a rnnv of tha ndac nr riirart nnactinnc to ill IMC ht/Tallinn Fr' 919 1QR7 nr 1 Ann 4,19 7144 �j� Issued By: �" Permittee Signature: 7:'� �i�1U� Call 503.639.4175 by 7:00 a.m.for the next available inspection date. i� This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. ..,..rawrr■rr Building Permit Application Residential FOR OFFICE Fsl:ONI.I City of Tigard 9 •��E'�EL Received Date/By: err PermitNo.:1ns co -7 13125 SW Hall Blvd.,Tigard,OR 9722 Plan Review / ■ I- Other Permit. �^ Phone: 503.718.2439 Fax: 503.598.1960 2 4 202� Date/By: 1(r/� 21i d�..f �� TIC A R D Inspection Line: 503.639.4175 MAY Date Ready/By: . s ^ I El See Page 2 for Internet: www.tigard-or.gov T r l,, r.Tir+ARi N • ed/Method: i /�� {�} Supplemental Information TYPE OF WORK REQUIRED DM'A:1-AND 2-FAMILYDWELLING ®New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application.t 4"''L►,-�, b`LQ ® I_and 2-family dwelling ❑Commercial/industrial Valuation: $ _./'` Number of bedrooms: LiAccessory building ❑Multi-family 5 ❑Master builder ❑Other: Number of bathrooms: 3 JOB SITE INFORMATION AND LOCATION Total number of floors:2 3V( CI Job site address: 16704 SW COLORADO LN New dwelling area: 3,205 square feet 6 City/State/ZIP:Sherwood, OR 97140 Garage/carport area: 439 square feet 1353 Suite/bldg./apt.no.: Project name:South River Terrace Covered porch area: "1 7 square feet Cross street/directions to job site: Deck area: i� square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: South River Terrace 1 Lot no.: 43 Permit tees*arc based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. New Construction/Type: SFU (4036 A) Valuation: $ Deferrals:YES-deferral of TSDC fees and park SDCs until occupancy. Existing building area: square feet Projected start: April 2022 New building area: square feet ® PROPERTY OWNER 0 TENANT Number of stories: Name:Taylor Morrison Northwest LLC Type of construction: Address:703 Broadway St., Ste 710 Occupancy groups: City/State/ZIP:Vancouver, WA 98660 Existing: Phone:(360) 946-8674 Fax:( ) New: ® APPLICANT 0 CONTACT PERSON U9 BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:Taylor Morrison Northwest LLC Structural plan review Ice(or deposit): Contact name:Omar Alami Abouhafs Address: 703 Broadway St., Ste 710 FLS plan review fee(if applicable): Total fees due upon application: City/State/ZIP:Vancouver, WA 98660 Amount received: Phone:(360)946-8674 Fax: :( )360 693-4442 E-mail: OAlamiAbouhafs@taylormorrison.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name:Taylor Morrison Northwest LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:703 Broadway St., STE 710 Solar Installation Specialty Code checklist. City/State/ZIP:Vancouver, WA 98660 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( )360 695-7700 Fax:( )360 693-4442 State surcharge(12%of permit fee): $21.60 CCB lic.:207247 �/ Total fee due upon application: $201.60 icy Authorized signature: () ai& 466' This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Print name:Omar Alami Abouhafs Date: 02/08/2022 Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(1 1/02/COM/WEB) Mechanical Permit Application FOR OFFICE City of Tigard Received Date/By: Petmit No.: � Z�IS 't 13125 SW Hall Blvd.,Tigard,OR 97223 � ( Plan Review 1' • Phone: 503.718.2439 Fax: 503.598.1960 Other Permit: Inspection Line: 503.639.4175 DatetRe IMAM') Date Ready/By: ]uric H See Pate 2 for Internet: vww.tinard-or.gov NolitlecUMethocI Supplemental Information TYPE OF WORK COMMERCIAL FEE* SCHEDULE - USE CHECKLIST Mechanical permit fees*are based on the value of the work ®New construction ❑Additionialteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:S CATEGORY OF CO\STRUCT'ION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ® l-and 2-family dwelling ❑ Commercial/industrial ❑ Accessory building For special information use checklist. i j Multi-family ❑ Master builder ❑Other Description 1 Qty. Ea. 1 Total JOB SITE LNFORMATION AND LOCATION Heating/cooling: Air conditioning 1 46.75 46.75 Job site address: 16704 SW Colorado LN Furnace 100.000 BTU(duets/vents) 1 46.75 46.75 City/State/ZIP:Tigard,OR 97224 Furnace 100,000 i BTU(ducts/vents) 54.91 Suite/b1d4Japt.no: Project name: South River Terrace Heat pump 1 61.06 61.0 Duct work 23.32 — Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hvdronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 _ Flue/vent for any of above 23.32 I Subdivision: South River Terrace_ other. 123.32 Lot no.: 43. _ _ Other fuel appliances: Tax map/parcel no.: Water heater 23.32 _ DESCRIPTION OF WORK Gas fireplace/insert 33.39— Flue vent for water heater or gas New construction-Type SFU fireplace 23.32 Log lighter(gas) I 23 32 Wood/pellet stove 33.39 Wood fireplace/insen 23.32 I Chimney/liner/flue/vent _ 23.32 E PROPERTY OWNER Other: 23.32 ❑ TENANT Environmental exhaust and ventilation: Name:Taylor Morrison Northwest LLC. Range hood/other kitchen 33.39 Address:703 Broadway St.,Ste.510 equipment 1 33.3g Clothes dryer exhaust 1 33.39 33.39 City/State/ZIP:Vancouver,WA 98660 Single-duct exhaust(bathrooms, 1 23.32 _toilet compartments,utility rooms) 23 32 Phone:(360)695-7700 Fax:( ) Attic/crawlspace fans 23.32 ® APPLICANT 0 CONTACT PERSON Other: 23.32 Fuel piping: Business name:Taylor Morrison Northwest LLC. S14.15 for first four;$4.03 for each additional Contact name: Omar Alami Abouhafs Furnace,etc. 1 Address:703 Broadway St-,Ste 510 Gas heat pump l Wall/suspended'unit heater I City/State/ZIP: Vancouver,WA 98660 Water heater _I _ Phone:(360)695-7700 ( Fax: :(360)693-4442 Fireplace 1 Ranee 1 E-mail:permitsuhmittalsrntaylormorrison.cOm Barbecue ,. CONTRACTOR Clothes dryer(gas) Business name:Pro Heating&Cooling Other: MECHANICAL PERMIT FEES* Address: NW Alociek Dr,Ste.1104 _ Subtotal I $262.84 C-iry,'State/ZIP:Hillsboro,OR Minimum permit fee(S90.00) Plan review(25%of permit fee) Phone:(360)270-1590 j Fax:( ) State surcharge(12%of permit fee) CCB lie.:209001 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 .Q, a bu�A days after it has been accepted as complete. Authorized signature: vvv w • Fee methodology set by In-County Building industry Service Board IPrint name:Elia Duran Date: 10/30/20 t 1A,.i1h,..APrrmrtc52,4FC P.rmt,Ann 11111111 rinr Electrical Permit Application City of Tigard Received • Date/By. Permit>3 4 13125 SW Hall Blvd,"Tigard,OR 97223 o-'�l ' _ - • Phone: 503.718,2439 Fax: 503,598.1960 Plan Review DateBy: Related Permit k: Inspection Line: 503.639.4175 TIGARLI Ready Date/B y, turfs 65 See Page 2 for to Internet: tvww.tigard-or.gov ' Notified/Method f Supplemental Information TYPE OF WORK PLAN REVIEW Q New construction ❑Addition'alteration +-epiacen ent Please check Si that apt Is(submit 2 sets of plans w•items checked) El Demolition O1}ter ❑Service or feeder 400 amps or more 0 Building over three stories. where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at I50 volts or p' 0 Floating buildings El 1-and 2-family dwelling ❑Commercial%industrial ❑Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural amps for all other installations buildings Q Multi-family ❑Master builder ❑Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency s R Y stem.Y larger separately derives! Job#: Job site address: 16704 SW Colorado LN ❑Addition of new motor load of system 100HP or more. ❑"A" "E" "I-2"'1-3" City/State/ZIP! Tigard,OR 97140 1 ❑Six or more residential units occupancy. I0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg,/apt.#: Project name: South River Terrace to Hazardous locations 0 Supply voltage for more than ❑Service er feeder 600 amps or more 600 volts n.urinal. Cross street/directions to job site: 1 FEE SCHEDULE Description I Qtr. I Each ] Total I New residential single-or multi-family dwelling unit. Subdivision: South River Terrace Lot k 43 1 Includes attached garage. Tax map/parcel Y: 1,000 sq.ftor less iI 168.54 {£:4, 4 Ea.add'l 500 sq ft or portion 3 33 92 101.76 i DESCRIPTION OF WORK Limited energy,residential 'Ness construction,Type SFU (with above sq.ft.) 75.00 2 Limited energy,multi-family residential(with above sq.It) 75.00 2 l PROPERTY OWNER Renewable Energy CI See Page 2 TENANT Services or feeders installation,alteration,and/or relocation Name: Taylor Morrison Northwest LLC. 200 amps or less 1 100.70 100.7 2 Address: 703 Broadway St.,Ste 710 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Vancouver,WA 98660 601 amps to 1,000 amps 301 04 Phone:( 360 )946 8674 Fax:( ) Over 1,000 amps or volts 552.26 2 Email: OAlamiAbouhafs{a taylormorrison.com-Perm itSubm ittals ar tar larnnorrison,com Temporary services or feeders installation,alteration,and/or relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale.lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125 O8 2 Owner signature: Date: ___ 401 amps to 599 amps 168 54 2 0 APPLICANT ❑ CON TACT PERSON Branch circuits-new,alteration,or extension,per panel A Fee for branch circuits with i Business name:Taylor Morrison Northwest LLC. above service or feeder fee, each branch circuit 7 42 Contact name: Omar Alami Abouhafs iB Fee for branch circuits without 4 Address: 703 Broadway Si,Ste 710 service or feeder fee,first 56.18 2 branch circuit City/State/Z1P: Vancouver,WA 98660 Each add'!branch circuit 7 42 2 Phone: 360 94b 8674 Miscellaneous(service or feeder not included) ( ) Fax: :( i Each manufactured or modular dwelling.service and/or feeder 67.84 2 Email:OAlamiAbouhafs'ii laylorrnorrison.com-Perm itSahmirtals is lay lurmorrison.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 Business name: A L_Pt i'll r :-v j t_ �rr,L i Y C- ` Sign or outline lighting 67 84 2 Address: 3'I i 5 w tE�t}L/t }hi !`-t 4- Signal circuits)or limited-energy t`'+ 'i `1 -t fill . panel,alteration,or extension. 0 See Page 2 City/State/ZIP: iy.r ci -77_1 Each additional inspection over allowable in anyof the above Phone:{ t� Additional inspection(!hr min) 66 25;hr ✓ }2, y 3 19,',..j 9 Fax:( ) Investigation(1 hr min) 90 001 hr Email: c, i.-- F 0 ..,o�'I industrial plant(1 hr min) 78 18,'hr r Inspections for which no fee is CCB Lic.: !99 i cz3 Electrical Lic.: �- Suprv.Lic.: q " speci ilea�listed 0/.1hr min) 1 9)00>hr Suprv.Electrician signature,required: d 2L LC Subtotal— ELECTRICAL PERMIT FEES . $202,46 Print name: Date: 10 -5- 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee). o a uric r i m TOTAL PERMIT FEE' Authorized signature: This permit application expires if a permit is not obtained within 180 Print name: p�t., --IA b tVI ()so—) Date: IQ-5j-21 days after it has been accepted as complete. • Number of inspections allowed per permit I.\Buiiding Permits\ELC PermitApp_ELR_ERE.doe Rev O it1"2n15 440.4615T(1 t,05/COMIWEa Plumbing Permit Application Building Fixtures FOR OFFICE USE ONLY City of Tigard Received Permit Nn.: -'r 13125 SW Hall Blvd.,Tigard,OR 97223 Datz`By: M���(5�� '`(� � j r Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit No.: TIGARD Inspection Line: 503.639,4175 Date Ready/By: Jura: RI See Page 2 for Internet: www.tigard-or.gov Notifcd/Method. Supplemental Information TYPE OF WORK FEE* SCHEDULE New construction ❑Demolition For special information use checklist. -- - Description I Qty. I Es. J Total ❑Addition/alteration/replacement ❑Other: New 1-2-fancily dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ,l•and 2-family dwelling ❑Commercial/industrial SFR(2)bath 437.78 SFR(3)bath 1 500.32 500.32 ❑Accessory building VI-Multi-family Each additional bath/kitchen 25.02 0 Master builder ❑Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: M__ Job site address: 16704 SW Colorado LN Catch basin or area drain 18.76 CitytStatefLiP:Tigard,OR 97224 Drywell,leach line,or trench drain 18.76 Footing drain(no.linear ft.: ) 1 Page 2 Suite/bldg/apt.no,: Project name:South River Terrace _ Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 Rain drain connector 18.76 Sanitary sewer(no.linear ft.: ) l Page 2 Storm sewer(no.linear ft.:_) I Page 2 Water service(no.linear ft.:_) ( Page 2 Subdivision: South River Terrace Lot no.: 43 Fixture or item: Tax map/parcel no.: Back-flow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 New construction-Type SFU Clothes washer 1 25.02 25.02 Dishwasher 1 25.02 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 ® PROPERTY OWNER l ❑ TENANT Expansion tank 12.51 Fixture/sewer cap 25.02 Name: Taylor Morrison Northwest LLC. Floor drain/floor sink/hub 25.02 Address:703 Broadway St.,Ste 510 Garbage disposal 25.02 City/State/ZIP:Vancouver,WA 98660 Hose bib 2 25.02 50.04 Phone:(360)695-7700 Fax:( ) Ice maker 12.51 ® APPLICANT ❑ CONTACT PERSON Interceptorigrease trap 25.02 Business name: Taylor Morrison Northwest LLC. Medical gas(value:S ) Page 2 Contact name: Omar Alami Abouhafs Primer 12.51 Roof drain(commercial) 12.51 Address:703 Broadway St.,Ste 510 Sink/basin/lavatory I 25.02 City/State/ZIP:Vancouver,WA 98660 Solar units(potable water) 62.54 Phone:(360)695-7700 Fax: :(360)693-4442 Tubishower/shower pan 12.51 Urinal 25.02 E-mail:permitsubmittals ltaylormorriSOD.com Water closet 25.02 CONTRACTOR Water heater 37.52 Business name:C&B Plumbing&Sons Inc Water piping/DWV 55.29 Address:P.O.Box 92 Other: 25.02 City/State/ZIP:St.Paul,OR 97137 Subtotal 600.40 Phone:(503)868-1417 Fax:(971)727-8170 Minimum permit fee: S72.50 Plan review (25%of permit fee) CCB Lic.: 184372 Plumbing Lic.no.:pb634 State surcharge(12%of permit fee) I Authorized sigmature: Y TOTAL PERMIT FEE Print name:Steve Fowler Date: 10/30/20 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. "Fee methodology set b;Tri-County Building Industry Service Board 1 liwiduit,Ferrnils\PLM U-PermitApp.sine I0,0I109 440-4616-rt eeevCOM4wEB) City of Tigard q COMMUNITY DEVELOPMENT DEPARTMENT illi 1 r,c A R D Building Permit Review — Residential Building Permit #: YIN 5Tr}0 - 15 7 Site Address: 010/4 11\J Coltxcx T Project Name: `2‘c -(e'(Y'aa_ Lot #: A 3 Plan ing Review Pro oral: \ _ tin Verify address/suite#ac 'ye in Accela. r In River Terrace: ❑ No El Yes,River Terrace Review Addendum Site Plan Elements: 1 osion Control !, copies of site plan on 8-1/2"x 11"or 11 x 17"paper V'etained trees with drip line and tree protection measures ;1 Drawn to scale(standard architect or engineer scale) N1 Fs tprint of new structure(including decks)and FFE ►'•, orth arrow i locations&easements(required for new and additions) 01 ite address,project or subdivision name and lot number l lk/driveway approach 114 pplicant information(name and phone number) oca' n of wells/septic systems Did; of dimensions and building setback dimensions S eet tree size,type and location l'iquare footage of buildings to be demolished S eet names .4 xisting structures on site Corner elevations(2'contours if more than 4'differe al) Lot area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replaced? Le'4'es ❑ y impervious area(applicable if R-7,R-12,R-25&R-40) If yes,is a storm water quality facility shown? ❑Yes 1:�A #EieanWater Services—Service Provider Letter (lot platted prior to 9/10/1995): quired: ❑ Yes,applicant was notified ❑ No Received: ❑ Yes ❑ No A ater Meter Fixture Unit Worksheet—Additions,Remodels and ADUs .'equired: ❑ Yes,applicant was notified ❑ No Received: ❑ Yes ❑ No \11 SDC Exemption for ADU applied for: ❑ Yes ❑ No Received: ❑ Yes ❑ No ❑ Public Facilities Improvement(PFI)Permit: Required: ❑ Yes,applicant was notified ❑ No Applied For: Yes ❑ No,stop intake 1LandUse Case#: ?VV./016— 03 4 Zoning: Required Setbacks: Front: ,l.,• Rear: l Side: Street Side: < Garage: 2 (7 il3 wilding Height: Max. Height: Actual Height: VI Landscap Area: 1/10 % Lot Coverage M : ntrance Set back no more than 8'from street-fac ng wall Para elll to street or offset 45 degrees or less Windows Minimum 12%of area of all street-facing facades Garage Garage door is behind widest street-facing wall V Yes ❑ No,one of the following is met: ❑ Door extends no more than 5'from wall and there is a covered porch extending beyond garage. ❑ Door extends no more than 5'from wall and there is a 12 sq ft.window above garage on 2nd floor. ❑ Garage door width is ❑ 12'or less 50%or less of facade ❑ 60%or less and includes 7 of following: ;! ❑ Covered porch ❑ Recessed entra ce ❑ Wall offset ❑ 1'Roof eave ❑ Roof offset ❑ Fire shingles ❑ Lap Siding ❑ Roof pitch ❑ Gable,hip,or gambrel roof ❑ Dormer /( ❑ Accent siding M Window trim ❑ Window recess ❑ Window projection ❑ Balcony G Ntg Visual Clearance ►1 Urban Forestry Plan ❑ Sensitive Lands: ❑ Yes CS No Type: ¢l Conditions met prior to issuance of building permit Notes: TApproved By Planning: '� , Date: ���/Z- evisions (after BuildingSubmittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved I:\Building\Fonns\B1dgPermitRvw_RES_122419.docx Building Permit Submittal Original Submittal Date: Site Plans: # Building Plans: # Building Permit#: nix building permit above.g � � g Workflow Routing: lannin n neerin ermit Coordinator uildin Workflow Sign-off: Ke�ign-off for Planning(include notes from planning review) Route Application Documents: Engineering: (1) copy of permit application, (1)site plan, (1)building plan and original_� plan review routing form. l<ding: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: Date: 5/j0? s Engineering Review IV/ Slope at building pad: /�`1. "Conditions "Met"prior to issuance of building permit ,_,/Easements (encroachments)per engineering conditions of approval and plat [ Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes [ /No I Assess Water Quantity Fee in-lieu: ❑ Yes [ 'No LIDA Facility on lot: ❑ Yes [V No Final Plat Recorded: ❑ NOT Approved by Engineering: Date: Notes: pproved by Engineering: Date: __26 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Permit Coordinator Review Conditions "Met"prior to issuance of building permit ❑ Approved,NOT Released: Date: Notes: Revisions(after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: SDC Exemption: ❑ Received ❑ Does not apply SDC Fees Entered: Wash Co Trans Dev Tax: ❑ Yes ❑ N/A / � • Tigard Trans SDC: ❑ / v�XYes ❑ N/A Parks SDC: 0 Yes ❑ N/A LIDA ❑ Yes 1 Y N/A OK to Issue Permit Approved by Permit Coordinator: ? I I t r6 Date: l// 0 • Z I:\Building\Forms\BldgPermitRvw_RES_122419.docx City of Tigard Deferral Until Occupancy Request TIGARD Washington County Transportation Development Tax (TDT),Transportation and Parks System `' Development Charges (SDCs) This form is to be signed and submitted prior building permit issuance or,if no building permit is required,then upon land use approval (TMC 3.24, as amended by Ordinance No. 21-09). Date: 6/6/2022 Site Address: 16704 SW Colorado Lane Project South River Terrace Land Use Case or MST2022-00157 Name: Building Permit#: Tax Lot Total Parks #: 2S1070001302 Amount*: $8,017.00 Lot 43 TDT N/A Total TSDC $10,348.00 Amount: Amount*: *The total TSDC amount shown above is the sum of$6,690.00 for TSDC-Improvement,$386.00 for TSDC- Reimbursement,and$3,272.00 for TSDC-River Terrace,if applicable.. *The total Parks SDC amount shown above is the sum of$ 6,278.00 for Parks-Improvement, $ 1,739.00 for Parks- Reimbursement,and either$ N/A for Parks-Neighborhood or$ N/A for Parks-Neighborhood River Terrace. This constitutes my request to defer payment of the TDT,TSDC, and Parks SDCs, as provided above, until occupancy. Payment of the TDT,TSDC, and Parks SDCs may be deferred until issuance of the occupancy permit. In requesting this option, I understand that any deferred TDT,TSDC, and Parks SDCs must be paid prior to final inspection or issuance of an occupancy permit. TDT may only be deferred if the TDT is greater than the amount for a single-family residence. I further understand that the amount of TDT due on deferred obligations shall be the amount in effect at the time of issuance of the building permit. For a deferral request to be accepted both the Property Owner and the Developer must sign this request. Property Owner: (Taylor Morrison NW LLC) 4/ u 46ea/u764- Date: 6/6/2022 Developer: (Taylor Morrison NW LLC)00144,4 lame:.A6eli Date: 6/6/2022 Permit Coordinator: fitiKebib Date: 6/6/2022 CITY OF TIGARD MASTER PERMIT 1,1 COMMUNITY DEVELOPMENT Permit#: MST2022-00158 Date Issued: 08/17/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S1070001305 Jurisdiction: Tigard Site address: 16716 SW COLORADO LN Subdivision: SOUTH RIVER TERRACE Lot: Project: South River Terrace, Lot 44 Project Description: New detached dwelling. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 1297 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 3 Second: 1830 sf Garage: 564 sf Front: 12 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 3127 sf Value: $437,245.58 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 100 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add9 500 sf: 6 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 3127 Owner: Contractor: TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $28,093.51 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to f Ilow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR QG9_nn1_M1n thrniinh('AR OR') 1_nn0n Yni, brain a nnv of t ndee nr rfir y art n1 ieetinne to(ll iP iC b raiiinn rn2 929 R7 nr 1 RM 229 92dd Issued By: '�%�"'l „n Permittee Signature: �� l / Call 503.639.4175 by 7:00 a.m.for the next available inspection date. c%Z`/�� This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. _._..__ CITY OF TIGARD BUILDING PERMIT `'1 COMMUNITY DEVELOPMENT Permit#: BUP2022-00180 Date Issued: 8/8/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S126DC00901 Jurisdiction: Tigard Site address: 9650 SW GREENBURG RD Project: Terrace Glen Apartments-West Building Subdivision: TERRACE GLEN APARTMENTS Lot: None Project Description: 80.96 KW roof mounted solar photovoltaic system. Contractor: IMAGINE ENERGY LLC Owner: GETHSEMANE EVANGELICAL 5506 SE INTERNATIONAL WAY LUTHERAN CHURCH MILWAUKIE, OR 97222 9640 SW GREENBURG RD PORTLAND, OR 97223 PHONE: 503-477-9585 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: MF Class of Work: OTR Type of Const: VB Permit Fee-Additions,Alterations, 08/08/2022 $1,299.23 Occupancy Grp: R-2 Occupancy Load: 0 Demolition 12/o State Surcharge-Building 08/08/2022 $155.91 Dwelling Units: Plan Review 07/14/2022 $844.50 Stories: Height: ft Info Process/Archiving-Sm$0.50(up to 08/08/2022 $6.00 Bedrooms: Bathrooms: 11x17) Value: $132,000 Floor Areas: Total Area: Accessory Struct: Basement: Carport: Covered Porch: Deck: Garage: Mezzanine: Total $2,305.64 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 95 -001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: � Permittee Signature: . /` b„ ` Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. NI CITY OF TIGARD MASTER PERMIT '' l '4 COMMUNITY DEVELOPMENT Permit#: MST2022-00282 Date issued: 08/31/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S111 BA06200 Jurisdiction: Tigard Site address: 14030 SW 97TH AVE Subdivision: ARLIE'S PLANTATION Lot: 2 Project: Nudelman Project Description: Solar photovoltaic system 6.08 kW, 2 circuits. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $8,816.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 2 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof top solar array 6.08 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: NUDELMAN,AARON&CELESTE ION DEVELOPER LLC Required Items and Reports(Conditions) 14030 SW 97TH AVE 3214 NORTH UNIVERSITY AVE TIGARD,OR 97224 503 PROVO,UT 84604 PHONE: PHONE: (888)781-7074 FAX: Total Fees: $457.42 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR ox,_nnillMf rhrn„nh CIAR oc9-nn1-nnon Yea,mov n ho rnlpc nr fllrp t n„ocenne In rll IMi' by nanine cnz 919 10 ne1'gnn 449 9414 Issued By: / Permittee Signature: Nall 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. iii CITY OF TIGARD MASTER PERMIT SJ'.. COMMUNITY DEVELOPMENT Permit#: MST2022-00283 Date Issued: 08/31/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S1038612000 Jurisdiction: Tigard Slte address: 12100 SW ANN PL Subdivision: YE-OLDE WINDMILL Lot: 39 Project: Hunt Project Description: Solar photovoltaic system 6.84 kW, 2 circuits. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $9,918.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bcktlw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K. 0 _ ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 2 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof top solar array 6.84 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: HUNT,JAKLIN ION DEVELOPER LLC Required Items and Reports(Conditions) BRYAN,ZANE 3214 NORTH UNIVERSITY AVE HUNT,DANA J ET AL 503 12100 SW ANN PL PROVO,UT 84604 TIGARD,OR 97223 PHONE: PHONE: (888)781-7074 FAX: Total Fees: $457.42 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or If work Is suspended for more the 180 days. ATTENTION: Oregon law requires you w the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc911M11n1n thrni inh CAP on9-nn'Lnnon Vnn maw nhta rnnw nit ndee nr riirert n,mefinne In nu min M,rauinn Sn1 919 1 nr 1 Ann'397 914d Issued By: Permittee Signature: �� 03.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. ihCITY OF TIGARD MASTER PERMIT 2 COMMUNITY DEVELOPMENT Permit#: MST2022-00203 T!!GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/30/2022 Parcel: 2S111 CCO2600 Jurisdiction: Tigard Site address: 10370 SW CENTURY OAK DR Subdivision: SUMMERFIELD Lot: 49 Project: McGraw Project Description: Bonus room addition, primary bedroom suite extension, and new roof over addition to match existing ridge, slope and Dutch gable. TRADE PERMITS TO BE PULLED SEPARATE. BUILDING Floor Areas Required Setbacks Required Stories: 1 Bedrooms: 0 First: 340 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 15 Smoke Dwelling Units: 0 Third: 0 sf Right: 5 Detectors: Total: 340 sf Value: $44,397.20 Rear: 15 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 340 Owner: Contractor: MCGRAW,JOHN S&KAREN L ARMOR CONSTRUCTION Required Items and Reports(Conditions) 10370 SW CENTURY OAK DR 11900 NE 18TH ST.CH 363 TIGARD,OR 97224 VANCOUVER,WA 98684 PHONE: PHONE: 360-600-3053 FAX: Total Fees: $1,099.65 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work Is suspended for more the 180 days. ATTENTION: •regon law re.'ires you t• follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR CIS?_nn1-nnin fhrnnnh CIA ..nni •,-•n V� a,i nhf�.�a rn of the,r l or riirarf ni m<finnc to ill INh by Tallinn col9Aj1QR7 or 1 Rnn'1'39 91 ` Issued By: i/A`/. . G�/f A r T' Permittee Signature: /71i t?527 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the fob site at the time of each inspection. n CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit#: BUP2022-00187 Date Issued: 8/11/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1 S135A601004 Jurisdiction: Tigard Site address: 10220 SW GREENBURG RD Project: Lincoln Center Subdivision: METZGER,TOWN OF Lot: 9 Project Description: Fourth floor restroom upgrades: Demolition, new walls,doors,finishes. Contractor: WALEN CONSTRUCTION Owner: LINCOLN CENTER LLC 20915 SW 105TH AVE BY SHORENSTEIN PROPERTIES LLC TUALATIN, OR 97062 235 MONTGOMERY ST, 16TH FLOOR SAN FRANCISCO, CA 94104 PHONE: 503-718-6680 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: Permit Fee-Additions,Alterations, 08/11/2022 $1,136.15 Demolition Occupancy Grp: Occupancy Load: 12%State Surcharge-Building 08/11/2022 $136.34 Dwelling Units: 0 Plan Review 07/27/2022 $738.50 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 08/11/2022 $274.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 08/11/2022 $454.46 Value: $104,400 Info Process/Archiving-Lg$2.00(over 08/11/2022 $14.00 11x17) Metro CET 08/11/2022 $125.28 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $2,878.73 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952- - 90. Y a btain a copy f th rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. i v Issued By: Permlttee Signature: /fA€ 522 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. ` This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT 4 '• COMMUNITY DEVELOPMENT Permit#: MST2022-00164 Date Issued: 08/25/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S108DC10100 Jurisdiction: Tigard Site address: 15797 SW VANDERWOOD AVE Subdivision: RIVER TERRACE CROSSING Lot: 109 Project: River Terrace Crossing, Lot 109 Project Description: New detached dwelling(Model Home.) NO FINAL INSPECTION UNTIL DEFERRED SDC FEES ARE PAID. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 1414 st Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 24 Bathrooms: 3 Second: 1597 sf Garage: 432 sf Front: 12 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 3011 sf Value: $423,534.14 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 6 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add"500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Y Audio&Stereo: N HVAC: N Securit Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 3011 Owner: Contractor: CND-RIVER TERRACE LLC STONE BRIDGE HOMES NW LLC Required Items and Reports(Conditions) 1111 N POST OAK RD 4230 GALEWOOD STREET#100 1 Ersn Cntrl 503-639-4175 HOUSTON,TX 77055 LAKE OSWEGO,OR 97035 PHONE: PHONE: 503-387-7577 FAX: 503-387-7615 Total Fees: $24,758.64 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work Is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR g69-nM-nnln rhrnllnh nAP oc9 1-nnon vn, P\,nhrAT o nu ni th ,iA<,,r rlerorr ni locenne to ni mu-.h„ramnn gn1 0A7 nr 1 Ann 119 owe ,O�y Issued By: Rermittee Signature: ` [� p f'`* Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. Y/' This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. 74 CITY OF TIGARD MASTER PERMIT a,` COMMUNITY DEVELOPMENT Permit#: MST2022-00178 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/23/2022 Parcel: 2S104AD05000 Jurisdiction: Tigard Site address: 12840 SW 129TH PL Subdivision: 2004-003 PARTITION PLAT Lot: 1 Project: LAMANNA, R C TRUST Project Description: Removing a portion of existing building and rebuilding the home. Erosion control under MST2022-00101 demo permit. BUILDING Floor Areas Required Setbacks Required Stories: 1 Bedrooms: 3 First: 2585 sf Basement: sf Left: 5 Parking Spaces: Height: 14.7 Bathrooms: 3 Second: sf Garage: 476 g sf Front: 20 Smoke Yes Dwelling Units: 1 Third: sf Right: 5 Detectors: Total: 2585 sf Value: $361,958.58 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 0 Drywall-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add.'500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 2585 Owner: Contractor: LAMANNA,R C TRUST 360 HOUSES REDO Required Items and Reports(Conditions) 5448 SW CHAMPION PL 3155 SW 199TH TER 1 Ersn Cntrl 503-639-4175 PORTLAND,OR 97225 ALOHA,OR 97003 PHONE: PHONE: 503-863-9709 FAX: Total Fees: $12,161.72 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of Issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 4:159_n01-NNn fhrniinh;(1_A17 og,..nM_ on Vnn rnal htai rnnv of tho nilac nr rlirort nimctinnc to(II IM P.by Tallinn F0'9'21O1QA7 nr 1 inn'119 9'Idd r� Issued By:`/�i� %�i' ���. Permittee Signature: !�tom' !i /Lcs9L}� Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job Site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit#: BUP2022-00176 Date Issued: 8/30/2022 TBGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S126CA01100 Jurisdiction: Tigard Site address: 9009 SW HALL BLVD 100 Project: US Bank Subdivision: None Lot: None Project Description: New 476 sq.ft.ATM building in the Target parking lot. Contractor: RBP CONSTRUCTION LLC Owner: DAYTON HUDSON CORPORATION 13380 NW MILL CREEK KDRIVE BY TARGET CORP T-0345 BEAVERTON, OR 97005 PROPERTY TAX DEPT/TPN-0950 PO BOX 9456 MINNEAPOLIS, MN 55440 PHONE: 971-291-3812 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: COM Class of Work: NEW Type of Const: IIIA Permit Fee-COM-New Construction 08/16/2022 $231.32 Occupancy Grp: U Occupancy Load: 0 12%State Surcharge-Building 08/16/2022 $27.76 Plan Review 07/18/2022 $150.36 Dwelling Units: 0 Wash Co Trans Dev Tax 08/16/2022 $504.46 Stories: 0 Height: 0 ft Tigard Trans SDC Improvement 08/16/2022 $381.54 Bedrooms: 0 Bathrooms: 0 Tigard Trans SDC Reimbursement 08/16/2022 $22.02 Value: $15,000 Info Process/Archiving-Lg$2.00(over 08/16/2022 $28.00 11x17) Info Process/Archiving-Sm$0.50(up to 08/16/2022 $48.00 Floor Areas: 11x17) Total Area: 0 DC Provision Review,COM TI-Ping 08/30/2022 $110.00 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $1,503.46 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You ay obtain a c y of the r s or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: 4 Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept In a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT~ COMMUNITY DEVELOPMENT Permit#: BUP2022-00193 Date Issued: 8/15/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S101AD03200 Jurisdiction: Tigard Site address: 12909 SW 68TH PKWY 190 Project: Mintun Subdivision: WEST PORTLAND HEIGHTS Lot: 9-25,PT Project Description: Remodel 4,092 sq ft of existing office space,including demo and construction of nonstructural walls,suspended ceilings,door,and frames. Contractor: PACIFIC REALTY ASSOCIATES LP Owner: PACIFIC REALTY ASSOCIATES L P 15350 SW SEQUOIA PKWY#300 ATTN: N PIVEN PORTLAND,OR 97224 15350 SE SEQUOIA PKWY#300 PORTLAND,OR 97224 PHONE: 503-624-6300 PHONE: FAX: 503-624-7755 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: I IB Permit Fee-Additions,Alterations, 08/11/2022 $1,000.53 Occupancy Grp: B Occupancy Load: 47 Demolition 12%State Surcharge-Building 08/11/2022 $120.06 Dwelling Units: 0 Plan Review 08/03/2022 $650.34 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 08/11/2022 $274.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 08/11/2022 $400.21 Value: $86,000 Info Process/Archiving-Lg$2.00(over 08/11/2022 $8.00 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $2,453.14 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are rth, n OAR 952-001-0010 through OA 52-001-009/O�You 7ay obt/aiii a ccoo(}�y of the rules or direct questions to OUNC by calling 503.232.1987 or 344. Issued By: ��A�v� ( ! -fi Permittee Signature: �� �`-^" //ll// -- Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept In a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. IS . CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2022-00277 T I CI A R.n 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/29/2022 Parcel: 1 S 134 CA05900 Jurisdiction: Tigard Site address: 12045 SW BURLH EIGHTS ST Subdivision: BURLWOOD NO.2 Lot: 32 Project: Parker Project Description: Solar photovoltaic system 9.88 kW, 2 circuits, Reinforce roof by sistering 2x6's to roof members supportinq solar system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $14,326.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywall-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>+.100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 2 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+ampNolt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuurn System: N Garage Opener: N All Y Roof topsolar array9.88 kW N Other: Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: PARKER,SETH&LARISSA ION DEVELOPER LLC Required Items and Reports(Conditions) 12045 SW BURLHEIGHTS ST 3214 NORTH UNIVERSITY AVE TIGARD,OR 97223 503 PROVO,UT 84604 PHONE: PHONE: (888)781-7074 FAX: Total Fees: $450.92 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR o ..rir iAnln thrnnn naR ac .n01..nnen Ynii v obtain n rnnv of that rulac nr dircrf n1 incline to Ill INC by onllinn 51.1. .9 10A7 nr 1 Ann 119 9%1A Issued By: C`1t,--✓ \ -' Permittee Signature: . .. J Call 503.639.4175 by 7:00 a.m,for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the iob site at the time of each inspection. CITY OF TIGARD MASTER PERMIT � COMMUNITY DEVELOPMENT Permit#: MST2022-00279 Date Issued: 08/29/2022 TIC A It D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S104CA02200 Jurisdiction: Tigard Site address: 13653 SW LAUREN LN Subdivision: HILLSHIRE Lot: 22 Project: Meinschein Project Description: Solar photovoltaic system 10.64 kW, 3 circuits BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $15,428.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bcklw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 3 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: MEINSCHEIN,SUSAN G TRUST ION DEVELOPER LLC Required Items and Reports(Conditions) 13653 SW LAUREN LN 3214 NORTH UNIVERSITY AVE TIGARD,OR 97223 503 PROVO,UT 84604 PHONE: PHONE: (888)781-7074 FAX: Total Fees: $465.23 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Q 2j i11-nn+n thrnnnh Fi 0c9-nnl-nnan vn,,n,av nhtain a rnnv of fha mlac nr dirp +ni iastinnc in rll INf:Mi Tallinn 5n. 979 10R7 nr I Ann 779 774.4. Issued By: Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT 111H4 '' COMMUNITY DEVELOPMENT Permit#: MST2022-00287 Date Issued: 08/30/2022 T1GAR.0 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S109A603500 Jurisdiction: Tigard Site address: 14176 SW 133RD AVE Subdivision: THREE MOUNTAINS ESTATES Lot: 28 Project: Hirl Project Description: Solar photovoltaic system 8.61 kW and panel upgrade BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $26,550.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodsloves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL _Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea add9 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio 8 Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof top solar array 8.61 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: HIRL,JOY REVOCABLE LIVING TRUST PREMIER SOLAR NW Required Items and Reports(Conditions) 14176 SW 133RD AVE 12399 NW WAKER DR TIGARD,OR 97224 PORTLAND,OR 97229 PHONE: PHONE: 503-799-9042 FAX: Total Fees: $474.47 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you ollow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9-nnl-nn-ln rhrn„nh nap g9911n1-nrlgn Vn„mmr nhtp m rnnu n the n ileac nr rlirert m,pctinnc to nl inlet hu rellinn Sn1 9 qa7 nr 1 Ann 19 9 d{l Issued By: ermittee Signature: 3.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT 'rli.I ' COMMUNITY DEVELOPMENT Permit#: MST2022-00286 Date Issued: 08/30/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S114AB14100 Jurisdiction: Tigard Site address: 9375 SW JULIA PL Subdivision: KNEELAND ESTATES NO.2 Lot: 106 Project: Rousculp Project Description: Solar photovoltaic system 8.64 kW with panel upgrade. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $40.600.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=10OK: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof top solar array 8.64 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: ROUSCULP,JOSHUA N&REBECCA Q PREMIER SOLAR NW Required Items and Reports(Conditions) 9375 SW JULIA PL 12399 NW WAKER DR TIGARD,OR 97224 PORTLAND,OR 97229 PHONE: PHONE: 503-799-9042 FAX: Total Fees: $474.47 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR QS9_n01_nMn thrnunh nnta QS9_eM llnQn Vni nhtnin n,n aloe nr rlirnrt nneMinnc in(•I INl:1,i Tallinn Fn '0 10 nr an 7 r /7 Issued By: ---1-- / Perrfittee-Signature: 03.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept In a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 114 CITY OF TIGARD BUILDING PERMIT 1. COMMUNITY DEVELOPMENT Permit#: BUP2022-00191 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 8/29/2022 Parcel: 2S111 CD02600 Jurisdiction: Tigard Site address: 9690 SW SUMMERFIELD DR Project: Summerfield Civic Association Subdivision: SUMMERFIELD NO.7 Lot: L Project Description: Installing new left in shed. Contractor: Owner: SUMMERFIELD CIVIC ASSOCIATION 10650 SW SUMMERFIELD DR TIGARD, OR 97224 PHONE: PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 08/29/2022 $619.25 Occupancy Grp: S-1 Occupancy Load: 10 Demolition 12%State Surcharge-Building 08/29/2022 $74.31 Dwelling Units: 0 Plan Review 07/27/2022 $402.51 Stories: 0 Height: 0 ft Bedrooms: 0 Bathrooms: 0 Info Process/Archiving-Lg$2.00(aver 08/29/2022 $10.00 11x17) • Value: $40,000 Info Process/Archiving-Sm$0.50(up to 08/29/2022 $3.00 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $1,109.07 Required: Required Items and Reports(Conditions) 1 Ersn Cntrl 503-639-4175 Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth In OAR 952-001-0010 throughh OAAAR952-001-000� ..%9900... You may obtain a copy of the rules or direct questions to OUNC by calling 503 232 1987 or 1.800.332.2344. `- '11y ! ( Issued By: - r/ Permittee Signature: I � • ,Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT = a COMMUNITY DEVELOPMENT BUILDING BUP2022-00188 Date Issued: 8/22/2022 T t C;A R 1) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S102AA03000 Jurisdiction: Tigard Site address: 8740 SW SCOFFINS ST Project: Custom Dental Prosthetics Subdivision: TIGARD HIGHWAY TRACTS Lot: 24 Project Description: Converting engineering office to dental lab. Contractor: BNK CONSTRUCTION INC Owner: LNL PROPERTIES LLC 45 82ND DR, SUITE 53B 12641 ADRIAN CT GLADSTONE, OR 97027 LAKE OSWEGO, OR 97034 PHONE: 503-557-0866 PHONE: FAX: 503-557-1085 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 08/22/2022 $1,407.95 Occupancy Grp: B OccupancyLoad: 70 Demolition P y 12%State Surcharge-Building 08/22/2022 $168.95 Dwelling Units: 0 Plan Review 07/26/2022 $915.17 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 08/22/2022 $434.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 08/22/2022 $563.18 Value: $150,000 Info Process/Archiving-Lg$2.00(over 08/22/2022 $10.00 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $3,499.25 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You )ay obtain a co py of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: ��' � i Permittee Signature: sr /47� [ Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection.