Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (2)
Pl','-. �l-o� Bie o IS ON OFFICE copy WYATT FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 972232 PECK RUBANOFF & � � HATFIELD2-10 12909 SW 68TH PARKWAY CTR TIGARD, OR 97223 FIRE PROTECTION EQUIPMENT SUBMITTAL COo Worldwide www.tyco-fire.com Contacts Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage EEMr General The TYCO Series TY-FRB Sprinklers ' "M "'14 Description described herein must be installed and maintained in compliance with The TYCO Series TY-FRB,5.6 K-factor, this document, as well as with the Upright (TY313) and Pendent (TY323) applicable standards of the National Sprinklers described in this data sheet Fire Protection Association,in addition are quick response,standard coverage, to the standards of any other authori- 'r decorative 3 mm glass bulb-type spray ties having jurisdiction.Failure to do so sprinklers designed for use in light or may impair the performance of these ordinary hazard,commercial occupan- devices. ` cies such as banks, hotels, and shop- The owner is responsible for main- ping malls. taining their fire protection system The recessed version of the Series and devices in proper operating con- TY-FRB Pendent Sprinkler, where dition. Contact the installing contrac- ' applicable, is intended for use in areas for or product manufacturer with any with a finished ceiling. This recessed questions. pendent sprinkler uses one of the �Vla following: Sprinkler �� � & • A two-piece Style 15 Recessed ' p y Identification £ Escutcheon with recessed adjust- Y� ment up to 5/8 in. (15,9 mm) from Number (SIN) the flush pendent position. • A two-piece Style 20 Recessed TY313. . . . Upright 5.61K,1/2 in. NPT * Escutcheon with recessed adjust- TY323. . . .Pendent 5.61K, 1/2 in.NPT ' ment up to 1/2 in. (12,7 mm) from the flush pendent position. Technical The adjustment provided by the Data Operation Recessed Escutcheon reduces the accuracy to which the fixed pipe drops The glass bulb contains a fluid which to the sprinklers must be cut. Approvals expands when exposed to heat.When Refer to Table A the rated temperature is reached, the Intermediate level versions of Series TY-FRB Sprinklers are described in Maximum Working Pressure fluid expands sufficiently to shatter the p glass bulb, allowing the sprinkler to Technical Data Sheet TFP357. Sprin- 175 psi(12.1 bar) activate and water to flow. kler guards and shields are described 250 psi(17.2 bar)' in Technical Data Sheet TFP780. 'The maximum working pressure of 250 psi(17.2 bar) Design only applies to the listing by Underwriters Laborato- ries,Inc.(UL). Discharge Coefficient Criteria IMPORTANT K=5.6 GPM/psi'/2(80,6 LPM/bar'/2) The TYCO Series TY-FRB,5.6 K-factor, Refer to Technical Data Sheet Temperature Rating Upright (TY313) and Pendent (TY323) ' TFP2300 for warnings pertaining to Refer to Table A Sprinklers are intended for fire protec- regulatory and health information. tion systems designed in accordance Finishes with the standard installation rules Always refer to Technical Data Sprinkler:Refer to Table B Sheet TFP700 for the "INSTALLER recognized by the applicable Listing or WARNING" that provides cautions Recessed Escutcheon:White Coated, Approval agency(such as, UL Listing with respect to handling and instal- Black Coated,Chrome Plated,or Brass is based on the requirements of NFPA lation of sprinkler systems and com- Plated 13, and FM Approval is based on the ponents. Improper handling and Physical Characteristics requirements of FM's Loss Prevention installation can permanently damage Frame ............................Bronze Data Sheets).Only the Style 15 or Style a sprinkler system or its compo- Button......................Brass/Copper 20 Recessed Escutcheon is to be used nents and cause the sprinkler to fail Sealing Assembly...Stainless Steel w/TEFLON for recessed pendent installations. to operate in a fire situation or cause Bulb...............................Glass Compression Screw.................Bronze it to operate prematurely. Deflector..........................Bronze Page 1 of 4 AUGUST 2018 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* } I 5 7/16" (11,1 mm) 4 NOMINAL 2" �,I 0 h WH MAKE-IN (50,8 mm) 2 2.. �\�� I`�/ 1-3/8.. 3 (50,8 mm) (34,9 mm) RENC II/ FLATS 1 1/2 NPT** DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation Step 2. With pipe-thread sealant applied to the pipe threads, hand- The TYCO Series TY-FRB,5.6 K-factor, tighten the sprinkler into the sprinkler WRENCH RECESS Upright (TY313) and Pendent (TY323) fitting. (USE ONLY Sprinklers must be installed in accor- Step 3. Tighten the sprinkler into the END"A") dance with this section. sprinkler fitting using only the W-Type General Instructions 6 Sprinkler Wrench(Figure 2).With ref- FIGURE2 Do not install any bulb-type sprin- erence to Figure 1,apply the W-Type 6 W-TYPE 6 kler if the bulb is cracked or there is Sprinkler Wrench to the wrench flats. SPRINKLER WRENCH a loss of liquid from the bulb.With the Torque sprinklers 7 to 14 Ib-ft (9,5 to sprinkler held horizontally, a small air 19,0 N-m). bubble should be present. The diam- Recessed Pendent Sprinklers WRENCH eter of the air bubble is approximately The Series TY-FRB Recessed Pendent RECESS 1/16 in.(1,6 mm)for the 135°F(57°C)and Sprinklers must be installed in accor- 3/32 in. (2,4 mm)for the 286°F(141°C) dance with the following instructions. temperature ratings. � Step A. After installing the Style 15 A leak-tight 1/2 in. NPT sprinkler joint or Style 20 Mounting Plate over the should be obtained by applying a sprinkler threads,and with pipe-thread minimum to maximum torque of 7 to sealant applied to the pipe threads, 14 Ib-ft(9,5 to 19,0 N-m). Higher levels hand-tighten the sprinkler into the of torque can distort the sprinkler Inlet sprinkler fitting. with consequent leakage or impairment Ste B. Tighten the sprinkler into the PUSH WRENCH of the sprinkler. sprinkler fitting using onlythe W-T e IN TO ENSURE Do not attempt to compensate for 7 Recessed Sprinkler Wrench (Figure ENGAGEMENT insufficient adjustment in the Escutch- 3).With reference to Figure 1,apply the WITH SPRINKLER eon Plate by under- or over-tightening W-Type 7 Recessed Sprinkler Wrench WRENCHING AREA the sprinkler. Re-adjust the position of to the sprinkler wrench flats. Torque FIGURE 3 the sprinkler fitting to suit. sprinklers 7 to 14 Ib-ft(9,5 to 19,0 N-m). W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers Step C. After ceiling installation and The Series TY-FRB Upright and finishing, slide on the Style 15 or Style Pendent Sprinklers must be installed 20 Closure over the Series TY-FRB in accordance with the following Sprinkler and push the Closure over the instructions. Mounting Plate until its flange comes in Step 1.Install Pendent sprinklers in the contact with the ceiling. pendent position. Install upright sprin- klers in the upright position. TFP1T2 Page 3 of 4 Care and 2-7/8"DIA. (73,0 mm) Maintenance 2-1/4" DIA. The TYCO Series TY-FRB,5.6 K-factor, FACE OF (57,2 mm) Upright (TY313) and Pendent (TY323) SPRINKLEAi Sprinklers must be maintained and ser- FITTING 5/8"(15,9 mm) viced in accordance with this section. FLUSH Before closing a fire protection system 3/8±5/16"main control valve for maintenance (9,5±7,9 mm)work on the fire protection system rthat it controls, obtain permission to 1/8" shut down the affected fire protection MOUNTIN (3,2 mm) systems from the proper authorities SURFACE and notify all personnel who may be CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) affected by this action. — TY-FRB PLATE 3/4"(19,1 mm) Absence of the outer piece of an escutcheon, which is used to cover FIGURE 4 a clearance hole, can delay sprinkler SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) operation in afire situation. WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only 2-7/8"DIA. cleaned by means of gently dusting (73,0 mm) with a feather duster; otherwise, non- FACE OF operation in the event of a fire or inad- SPRINKLER 2-1/4" DIA. vertent operation may result. FITTING (57,2 mm) Sprinklers which are found to be 5/16±1/4" leaking or exhibiting visible signs of (7,9±6,4 mm) 1/2"(12,7 mm) corrosion must be replaced. FLUSH Automatic sprinklers must never be ? �� painted, plated, coated, or other- wise altered after leaving the factory. I 1 Modified sprinklers must be replaced. MOUNTING (3,2 1/8" Sprinklers that have been exposed to SURFACE corrosive products of combustion,but have not operated,should be replaced if they cannot be completely cleaned CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) by wiping the sprinkler with a cloth or TY-FRB PLATE 7/8"(22,2 mm) by brushing it with a soft bristle brush. FIGURE 5 Care must be exercised to avoid SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) damage to the sprinklers before, WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 during, and after installation. Sprin- RECESSED ESCUTCHEON klers damaged by dropping, striking, wrench twist/slippage,or the like,must Recessed Escutcheon be replaced. Also, replace any sprin- Limited Specify: Style 15 Recessed Escutch- kler that has a cracked bulb or that has Warranty eon with(specify*)finish,P/N(specify*) lost liquid from its bulb. (Ref. Installa- 1 Specify: Style 20 Recessed Escutch- tion Section.) For warranty terms and conditions,visit eon with(specify*)finish, P/N(specify*) The owner is responsible for the www.tyco-fire.com. *Refer to Technical Data Sheet TFP770 inspection,testing,and maintenance of their fire protection system and devices Sprinkler Wrench Ordering in compliance with this document, as Specify: W-Type 6 Sprinkler Wrench, well as with the applicable standards procedure P/N 56-000-6-387 of the National Fire Protection Asso- Specify: W-Type 7 Sprinkler Wrench, ciation (e.g., NFPA 25), in addition to Contact your local distributor for avail- P/N 56-850-4-001 the standards of any other authorities ability.When placing an order, indicate having jurisdiction.Contact the install- the full product name and Part Number ing contractor or product manufacturer (P/N). with any questions. sprinkler systems are rec- Sprinkler Assemblies with NPT Automatics p y Thread Connections ommended to be inspected, tested, Specify: Series TY-FRB Upright or and maintained by a qualified Inspec- Pendent (specify) Sprinkler, SIN tion Service in accordance with local (specify), K-5.6, Quick Response, requirements and/or national codes. (specify) temperature rating, (specify) finish, P/N (specify,refer to Table A). TFP172 Page 4 of 4 SPRINKLER FINISH(See Note 7) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME pOLYESTER� FACTOR COLOR BRASS PLATED 135-F(57-C) Orange UPRIGHT 155°F(68°C) Red (TY313) and 175°F(79°C) Yellow 1,2,3,4,5,6 PENDENT (TY323) 200°F(93°C) Green 5.6 1/2 in.NPT 286°F(141°C) Blue RECESSE135-F(57-C) Orange PENDENT D 155°F(68°C) Red (TY323) 1,2,3,4 Figures;a and 5b 175°F(79°C) Yellow 200°F(93°C) Green Notes: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-54-428-3377.) 6. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. a. Installed with Style 15(1/2 in.NPT)5/8 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only.Listings and approvals apply to color(Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/Na 77 — XXX — X — XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 370 5.6K UPRIGHT(1/2 in.NPT) TY313 1 NATURAL BRASS 135 135°F(57°C) 371 5.6K PENDENT(1/2 in.NPT) TY323 3 PURE WHITE(RAL9010)a POLYESTER 155 155°F(68°C) Notes: SIGNAL WHITE(RAL9003) a. Use suffix"I"for ISO 7-1 connection;for example. 4 77-370-4-175-I POLYESTER 175 175°F(79°C) 5 JET BLACK(RAL9005) POLYESTER 200 200°F(93°C) 9 CHROME PLATED 286 286°F(141°C) Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Alto m 2018 Johnson Controls.Allrightsreserved.Allapeclficationeand other information shown werecurrant as of document revision date andare subject to change without notice. )ohnsonI NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Flre P--ti°n Association TEFLON is Controls a registered trademark°f Du— Eddythread 41 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems /�_ 1819 Clarkson Road For additional information, (�Vliws u 1 Chesterfield,MO 63017 contact your salesperson today at C L uS �L (800)325-4467 (800)325-4467 or(636)537-2600 LISTED II SSL-MoosE TLJESE 6 COMPAWY FAX:(636)537-2645 in the USA,or from Canada ���tit�.bullla�oc��ctube.c��m call(800)882-4666 FM A CAA company a-mallal��_�Ihu(ti�uxsui—bt.etmt -- - -- - --- APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 Ductile Iron Threaded Fittings b �A F f;. 3## { 6 Y �k SMITH -vC00PEJW I N T E R N A T 4 N A L Ductile Iron Threaded Fittings • Cj branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP • Ductile iron castings conform to ASTM A536 c@us LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 FM • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 Ductile II C ul US FM aPaO Fig. 35E 3-90°Elbow LISTED Size A Packin Weight in Part Number in Inner Master Ib 112 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 A 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 194 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-112 35E 3024 2 70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow B Size A B Packing Weight f ' in Part Number in in Inner Master Ib 314x1/2 35RE300600/1 1,20 122 80 160 0-3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 A 1 x 3/4 35RE3010006 1 38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 q21 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52_ 1.75 30 60 0.6 1-112 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-112 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-112 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 112 35RE3020004 1.60 1.97 18 36 1,0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1 73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-112 35RE3020014 202 2.16 10 20 lb 2-112 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-112 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size Part Number A Pac ing Weight �A in in Inner_ Master ib 112 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1 13 40 80 0.5 i 1-1/4 35F 3012 1.29 25 50 0.7 �A 1-112 351-3014 144 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-112 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size Part Number A Pac ing Weight in in Inner I Master ib �A 112 3513004 1.13 80 160 03 i 3/4 35T 3006 1.31 30 60 0.5 -�-- 1 3513010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 A 1-112 35T3014 1.911 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-112 3513024 2.70 4 8 4.3 11 8:A11,111-COOPER I\TFR NVION AI, TOI.I, FRI-; ", 1-800-766-0070 FAX(.323)1190-4456 0 sesc�c.smitharohcr.coim r ' Y 0 UL/FM Ceus FM APPROVED Fig. 35RT3-Reducing Tee LISTED Size Part Number A B C Pac ing Weight in in in in Inner IMasterl Ib i C 3/4 x 1,2 35RT3006004 1 20 1.20 1.22 60 120 0.4 i 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 - r-- - - 1 x 1/2x 1 35RT30 1000,10 10 150 1.36 1.50 30 60 0.6 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 B 1 x 3,`4 x 3/4 35RT3010006006 1.38 1 31 1.45 35 70 0.6 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1 114 x 112 35RT3012004 1 ,34 1 34 1.53 20 40 08 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1 1/4 X,3/4 35H 13012006 1 45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1 1/4 x 1 35R13012010 158 1.58 1.67 15 30 t0 1-1/4 x 1 x 112 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-114 x 1 x 3/4 35843012010006 1.45 1.38 1 63 20 40 0.8 1-114x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-114 x 1 x 1 1/4 35RT3012010012 1 75 1-69 1.75 15 30 1.0 1-112 x 112 35RT3014004 1.41 1.41 1.66 16 32 1.0 1 1r2 x 1/2 x 1 114 35RT301400,1012 1 81 1.56 1-88 24 48 1.1 1-112 x 112 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1 1/2 x 3/4 35H 13014006 1.52 1.52 1.75 16 32 1.1 1-112 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-112_ 35813014006014 1 94 1.75 1.94 18 36 1.2 1-112 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-112 x 1 x 112 35R 13014010004 1.44 1.25 1.69 20 40 C.8 1-112 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1 1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1 1/2 x 1 x 1-1/2 3581301401001,1 1-94 1.80 1.94 12 24 1-3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2x 1 114 x 1/2 35RT3014012004 1-41 1.34 1,66 16 32 0.9 1-112 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1 1/2 x 1-1/4 x 1 35RT3014012010 1-65 1,58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1 1i2 x 1-1!4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 '.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 314 35RI3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RI3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2x 1-1/4x2 35R M020012020 2 25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x 1-112 x 1/2 35RT3020014004 1,49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1 1 i2 x 1 35R 73020014010 1.73 1-65 2,02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1 112 x 1-1/2 35RT3020014014 2.02 1.94 2,16 8 16 1,8 Fig. 35BT3-Bull Head Tee Size Part Number A B C Pac ifto Weight in in in in Inner Master Ib 1 IC 3/4 x 1 35813006010 1.45 1.45 1.37 30 60 0.6 - 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 A F B 1-1/4 x 1 x 1-112 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1 88 1.88 1-82 15 30 13 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 216 2.10 2.02 10 20 1.8 1-112 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 S\111 H-COOPh:R [�"I'I,RN:1"CIO1.11." l OLI, FRI'.1'. 1-800-706-0076 9 1-ak (323)890-44ih V�WNti.snlidl000Pccc0m 112 Ductile Iron Fittings- Class 300 UL/FM C UL US FM APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size Part Number A PackingWeight in in Inner Master Ib 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 OA 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-112 35CP3021 3.00 9 18 22 Fig. 35RC3 -Hex Reducing Coupling Size Part Number A Packin Weight -� - in in Inner Master ib A 1 x 1/2 35RC3010004 1 69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 206 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packin Weight 1 B 1 in in Inner I Master Ib 1 x 1/2 35HB3010004 1 06 180 360 0 2 1A 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x 1 35HB3012010 1-19 90 180 0.2 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0-3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1-38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug Size Part Number A Packin Weight in in Inner Master Ib 172 35SP3004 094 600 1200 0.07 A 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 125 200 100 0.1 - - - - 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 1 90 1 0.6 Fig. 35U 3- Union with Brass Seat A Size Part Number A PackingWeight in in Inner Master Ib 1 35U 3010 2.19 20 40 10 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER (�'"I F:R�;A"t'IO\\I," 'COLI, 1"RE ? 1-800-760-0076 • FAX(323)890-4456 ���t��srnitha�uhcr.a�m 41111,110"$' �.t Ductile II --,- -.--._-r..-_ C @ US FM APPROVED Fig. 35X 3- Cross LISTED Size Part Number A PackingWeight � ;n in Inner Master Ib JA 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1.4 A 1-1/2 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 Fig. 35RX3-Reducing Cross H` B ' Size Part Number A B Pac ina Weight �A in in in Inner Master Ib x 1-1/4 1 3513X3012010 1.67 1.58 15 30 1.2 - ----- 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 I I �A 2 x 1 3513X3020010 2.02 1.73 8 16 2.0 I I Fig. 35C 3- Cap Size Part Number A Pac ing Weight in in Inner IMaster Ib A 1/? 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-112 35C 3024 1 70 18 36 1,6 Fig. 35BC3-Beam Clamp Size A Part Number Pac ing eight A A ;n in Inner Master Ib 3/8 35BC3003 0 75 100 200 0.3 1/2 35BC3004 0.75 80 160 0.5 S\111,114100111"R 1�'I F:I2 :A"I'IO�\L" • FOI,I. FkFIF. 1-800-706-0076 • FAX(_i23)'090-4456 NN%%Nc.xmiuhcaoprr.com 114 C uL IIS <9> Vd5 �LP l lT_P USTED 491a/27 STYLE 922 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Style 922 Outlet-T provides a convenient method of incorporating 1/i,3/4,and 1715, 20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems,Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300psi/2068kPa and VdS rated up to 16bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.' Contact Victaulic for other optional coatings. `Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code). Fire Lock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel (North America, Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICtaulEC° 10.52 STYLE 922 DIMENSIONS Nominal Si,e Hol' inches/mmLD . �.6 a# * _: -Y- Z- a /2 3/16 1 30 83 1,10 3.87 2.56 IC Tf� 32 X 15 302 330 465 27.9 98.3 65.0 0.45 V 3/4 13/16 1.28 1.83 1,10 3.87 2.56 1.1 20 302 32 5 465 27.9 98.3 65.0 050 W 1 13/16 1.52 2-18 110 3-87 2.56 12 25 302 38.6 54 279 983 65.0 0.54 1 V2X /z 13/16 1.42 1.95 1.22 4.08 256 L2 40 15 302 361 495 31.0 103-6 65-0 0.54 3/4 13/16 1.40 1,95 1.22 4.08 2.56 1.2 20 302 35.6 495 31.0 103.6 65.0 0.54 1 1 3/16 164 2 30 122 4.08 2.56 13 25 30-2 41 7 584 310 103.6 65.0 0.59 /2 13/16 1-66 2-19 1,46 4-60 256 1.3 2 2x 15 30.2 42-2 55-6 371 116.8 65.0 0.59 3/4 13/16 1.64 2.19 146 4.60 2.56 14 20 30.2 41.7 55.6 37.1 1168 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 068 2yz X 1/2 13/16 1.91 244 1.71 540 2.56 1.6 65 15 30.2 485 62-0 434 1372 650 0.73 3/4 1 3/16 1.89 2.44 1.71 5.4C 2.56 1.6 20 30.2 48.0 62.0 43A 137.2 65.0 073 1 13/16 2.13 2.79 1.71 5.40 2.56 1-6 25 302 54.1 70.9 43.4 137.2 65.0 0.73 761 mm X 11213/16 191 2.44 171 5.50 2.56 1-6 15 302 48.5 62.0 43.4 139.7 65.0 0.73 3/4 13/16 1.89 2,44 1.71 5.50 2.56 1.6 20 302 48.0 62.0 434 139,7 65.0 073 1 13/16 2.13 2.79 1.71 5.50 2.56 17 25 30.2 54.1 70.9 434 1397 65.0 080 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com '-Ill,.Ataulld VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.52 STYLE 922 PERFORMANCE Equivalent Length of I inch Schedule 40 Steel Pipe(per UL Run Size x Outlet Size 213,Section 16)(C-1200'.FT 1 8.5 32 X 25 2.6 11/2 1 85 40 X 25 26 2 1 85 50 X 25 2,6 21121 1 8.5 65 25 2.6 761 mm X 1 8.5 25 26 *Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. -Ctaulicr 1 ::%1► •� Bill" STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. Pipe Hangers Fig.200- "Trimline"Adjustable Band Hanger (B-Line Fig.B3170NF) 0TO-CO Fig.20OF- "Trimline"Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) c@ Fig.200C- "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LIVED Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut �MSize Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: 4 • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily Q B installed around pipe. For hanger with non-captured nut order Fig. 200S. A • (21/2" (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Fig.200-1/2.zoo-3/4 Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (200mm)). Fig.200-1 to 200-2 Fig.200-21/2 to 200-8 Conforms to Federal Specifications WW-H-171 E&A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69& SP-58, Type 10. Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. } Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. `1 Fig.200 Fig.200C Fig.20OF Pipe Size Rod Size A B Approx.Wt./100 Part No, in. Win) in. (mm) in. Win) Ibs. (kg) 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) 3/e%16 33/8" (85.7) 25/8" (66.7) 12 (5.5) 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) =` 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 16.4► 200-2 2" (5o) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" (65) 3/e°-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" 1101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6► 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8' (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" 1150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/9" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. R Fire Protection Solutions -Line 27 Bby lF.J. Y Threaded Accessories 83205 -Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) B3205L- Threaded Rod (right& left hand threads) TL Specify Length Size Range: 3/8"-16 thru 3"-4 rod 'L' Material: Steel TL Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown.Also A available with left and right hand threads-specify Fig. B3205L when ordering. Thread size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design o.d Thread Size Thread Length TL t' i' Part No. A in. (MM) Lbs. (kN) Lbs. (M) 83205-3/s x'L' 3/8"-16 21/2 (63.5) 730 572 B3205-1/2 x'L' 1/2"-13 21/2" (63.5) P4480 350 (6.00) 1057 (4.70) 8320.5-5/s x'L' 5/8"-11 21/2" (63.5) 160 (9.61) 1692 (7.52) 63205-3/4 x'L' 3/4"-10 3" (76.2) 230 (14.37) 2530 (11.25) B3205-7/ax'L' 7/8"-9 31/2" (88.9) (19.93) 3508 (15.60) B3205-1 x'L' V-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205.11/BXIt! 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) 83205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2x'L' 11/2"-6 6" (152.4) V1380O (61.38) 10807 (48.07) 83205-13/4 x'L' 13/4"-5 7" (177.8) 14566 (64.79) B3205-2 x'L' 2" 41/2 8" (203.2) 19625 (87.29) B3205-21/4 x'L' 21/4"-41/2 9" (228.6) 25295 (112.51) 1332W-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) 83205-23/4x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) 83205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.loo) Fig. 99 -All Threaded Rod Cut To Length Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length Material: Steel 1'101� 1, 0 Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number, rod diameter and finish Part No. Size x Length Threads Recommended Load Approx. ti ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/a"x 120 99-3/a"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1h"x length 13 1350 (6.00) 53 (24.04) ATR 5/9"X 120 99-5/a"X length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"X length 10 3230 (14.37) 123 (55.79) ATR 7/9"x 120 99-7/a"X length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Une Pipe Hangers&Supports 236 Revised 4128/2014 by F:T*N ZRA701s Me Not less than 2"nominal wid Wood Flooring th "-Oxl?"t-os -No pre-drilling required. Not less than Quick to install using the Sammy 3"nominal thickness(2-1/2") Nut Driver with an 18V cordless (depth or side Wood Joist drill/driver. of vertical member) Saves time from traditional Double Sheetrock Ceiling methods. Reduces installation cost. M ade in the U.S.A. 1/4* BM2957 GST100 1/4 x 1" 210(7/16'OSB) 670(3/4'Ply) 25 125 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4* 8004957 GST 3DO 1/4 x 3" 2060(Fir) 25 125 3/8" 8006957 GST.75 1/4 x 3/4" 564 (3/4"Ply) 25 125 3/8" 8007957 GST 10 114 x 1" 210(7116'OSB) 300 25 125 670(314'Ply� 3/8" 8008957 GST 20 114 x 2" 1760 (Fir) 850 1475 25 125 3V 8068925 GST 20-SS 114 x 2' 1760(Fir) 850 25 125 3/8" 8009925 GST 25-380 318 x 2-1/2" 2113 (Fir) 1500 25 125 #14 Black 3V 8010957 GST 30 1/4 x X 2060(Fir) 1500 1475 25 125 N t Driver 3/8" 8069925 GST 30-SS 114 x 3" 2060 (Fir) 25 125 Partu#8113910 3/8' 8011925 GST 40 114 x 4" 2180(Fir) 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 _j 1/2' 8013925 GST 2 114 x 2' 1760(Fir) 25 125 —1, 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 25 1 1/7 8015925 GST 3 1/4 x 3" 2275(Fir) 25 125 �L 112" 8016925 GST 4 114 x 4" 2180 (Fir) 25 125 1/2" 8017925 GST 6 1/4 x 6" 2230(Fir) 25 125 414 SW Red Nut Driver Part#8114910 Eliminates distortion of threaded rod. Saves time from traditional methods. Accommodates up to 3%"x 12 pitch roof. Reduces installation cost. Allows 17'deflection from vertical. Made in the U.S.A. 211 11 3/8' 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 125 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 1#14'Black Nut Driver i_�_.V The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut adver for installations. ft— I 2111111 f RoHS) OFFICE copy RECEIVED AUG 2 2 CITY OF TIGARD BUILDING DIVISION SAMMY SIDEWINDER (GS ALL THREAD R 1 ADJUSTABLE RING HANGER I LS ;i L......... HANGER DETAIL �_-__ ._.. m d. NOT TO SCALE l I I i fi i l ____. _ _ _U __ t t t v s � I , ks REFLECTED CEILING PLAN N 0' 48' 16' NOTES RECISIONS SPRINKLER SYMBOLS Meets design requirements of NFPA 13 2016 edition. T1/f5,6 FP-1 All piping to be schedule 40 w screwed ductile iron fittings. r' ° TY323 �P- FCh/Ch ' '�' 2 PECK R U B A N O F F & HATFIELD PEFUT Ail h ngers to be per NFPA 13 requirements. g ssP tss 1/27 5 W YAT T12909 SW 68TH PARKWAY CENTER CONTRACT N0. C22-51All armovers greater than 2'-0" shall be provided with hangers. SSP- FIRE PROTECTION, INC. DRAWN BY R.CAMPSELLAll of work area will be light hazard occupancy. np 155 1 Y SCME 1 '-t'-Max. sprinkler spacing to be 225 sq. ft. per head. 19095 S.W.Burnham TI GARD, OR 97223 DALE 19 AUG 2022 All heads cut in from branch lines. Tigard.OR 97223 DATE REIASED (503)684-2928 VANOSDEL,P.O.BOX 1057 BATTLEGROUND WA 98804 1 OF 1