Loading...
Report Models G and GB • General Clean Air • Light Contaminants • Seismic • High Wind • Variable Volume Y t, Itl s Nerformancedata included .. jlf WPM December 020 2 Spur AAN_4M3'r1UiM"' 10 Dovf,11N',;ast Building Value in Air. Genuli-lugal Roof Exhaus, Fans Contents PERFORMANCE AND DIMENSIONS: Model Comparison. . . . . . . . . . . . . . . . . . . . . .3 Direct Drive Construction Features . . . . . . . . . . . . . . . . . 4-5 Models G-060-160 . . . . . . . . . . . . . . . . 15-28 Emergency Smoke Control . . . . . . . . . . . . . . .6 Model G-180 . . . . . . . . . . . . . . . . . . . . . . . .30 Models G-200-200HP. . . . . . . . . . . . . . 32-33 Seismic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Model G-240 . . . . . . . . . . . . . . . . . . . . . . . .36 High Wind & Hurricane. . . . . . . . . . . . . . . . . . .7 Model G-300 . . . . . . . . . . . . . . . . . . . . . . . .39 Vari-Green' Motor, Controls, Drive. . . . . . 8-10 Belt Drive Demand Control Ventilation. . . . . . . . . . . . . . .9 Models GB-097-540 . . . . . . . . . . . . . . . 19-47 Roof Curbs, Options and Accessories . . 11-12 Quick Build Programs . . . . . . . . . . . . . . . . . .48 Typical Installations. . . . . . . . . . . . . . . . . 13-14 Our Commitment . . . . . . . . . . . . . . . . . . . . . .48 Model Number Code . . . . . . . . . . . . . . . . . . .14 Greenheck Fan Corporation certifies that the Models G and GB fans shown herein are licensed to bear the AMCA Seal.The ratings shown are C o L US LISTED fOU110 based on tests and procedures performed in Aii accordance with AMCA Publication 211 and rrvunm0 G and GB models are listed for electrical *UL/c UL is optional Publication 311 and comply with the requirements (UUcUL 705)File no.E40001 of the AMCA Certified Ratings Program.The and must be specified certified ratings for Models G and GB are shown ( U models for Emergency Smoke Control Systems UcUL Listed for 500°F(260°C)for 4 hours and on pages 15-47 1,000°F(538°C)for 15 minutes)File no.MH17511 Enjoy Greenheck's extraordinary service, before, during and after the sale. Greenheck offers added value to our wide selection of to performing,� D pp g, ener 9Y- efficient 2, products by providing several unique Greenheck service programs. • Our Quick Delivery program ensures shipment of our in-stock products within 24 hours of placing g your order. Our Quick Build made-to-order products can be produced in 1-3-5-10- 15-20 or 25-day production cycles, depending upon their complexity. • eCAPSO online selection guides you to choose the best value product for your building projects. It includes fan, louver and dedicated outdoor air systems (DOAS) selection, as well as a damper guide and toolbox. • Greenheck's free Computer Aided Product Selection (CAPS®) program, rated by many as the best in the industry, helps you conveniently and efficiently select the right products for the challenge at hand. • Our 3D service allows you to download, at no charge, easy-to-use AutoDesk® Revit® 3D drawings for many of our ventilation products. Find out more about these special Greenheck services at greenheck.com 2 . .. mod. As G and G" [MGREENHECK Spur _q Value in Air. 10odel Comparison Impeller Location Mounting Airflow Application Drive ImpPerformance Type Type Q � E J N ~ d Model ¢ ¢ c NE rn •• c a m cc o m cCO 3 o rn �a U c m U c o C', rn o E E i O Ucc C CL � C O X3 O A C > C C O E XE N�G ,O S ¢ a v CO 0 W im UM 2 2ay i5i 18 G ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 14,500 2.75 GB I -/ I I -/ I -/ / I I _/ I ✓ ✓ I I / I V/ I 1 1 44,700 3.25 "Smoke control available on models: 100, 100HP,120,130, 140,140HP,160,160HP, 200,240,300,360,420 and 480 **High wind limited to sizes 300 and smaller Greenheck models G and GB centrifugal roof exhaust Direct Drive, G fans provide the industry's best performance and • Use for short and/or low resistance ductwork durability for general clean air applications where air is discharged downward,toward the roof surface. Belt Drive, GB • Broadest performance in the industry, up to 3.25 in. wg (810 Pa)and 44,700 cfm (75,945 m3/hr). For average length and/or average resistance ductwork • Most advanced motor cooling of any fan in its class. . High volume/average pressure • Performance as cataloged is ensured.All fan sizes are tested in our AMCA accredited laboratory, and High Pressure, G-HP and GB-HP all models are licensed to bear the AMCA Sound . For long and/or high resistance ductwork and Air Performance seals. • UL Listed for electrical. • Low volume/high pressure • Greenheck subjects these products to extensive life testing ensuring the fans will provide years of reliable performance. 3' .s 4 E t,$ 5 IIS a., 3 LMGREENHECK Building Value in Air. Standard Construction Features A backward-inclined, non-overloading centrifugal wheel is utilized to generate high- Wheel efficiency and minimal sound.Wheel cones are carefully matched to the venturi for maximum efficiency. Each wheel is robotically welded and statically and dynamically balanced for long life and quiet operation. Disconnect NEMA-1 switch is factory-mounted and wiring is provided from the motor as standard Switch (other switches are available).All wiring and electrical components comply with the National Electrical Code®(NEC) and are either UL Listed or Recognized. Precisely sized, ground and polished, so the first critical speed is at least 25% over ® Fan Shaft the maximum operating speed. Where the shaft makes contact with bearings,tight tolerances result in longer bearing life. 0 Bearings 100% factory tested and designed specifically for air handling applications with a minimum L10 life in excess of 100,000 hours(L50 life of 500,000 hours). Motor Carefully matched to the fan load and mounted out of the airstream. Motor Cover Constructed of aluminum and attached with fasteners for easy removal and access to motor compartment and drive assembly. Cooling fins located on top of the fan wheel draw outside air through a large space ® Motor Cooling between the fan shroud and the motor cover directly into the motor compartment. Positive motor cooling with fresh air results in maximum motor life. 0 Lifting Points Various lifting points are located on the drive frame and bearing plate(on select sizes). �J d True Vibration Vibration isolators, with no metal-to-metal contact, support the drive assembly and Isolation wheel for long life and quiet operation. Drive Assembly Belts, pulleys, and keys are oversized 150% of driven horsepower. Machined-cast pulleys are adjustable for final system balancing. Belts are static-free and oil-resistant. Lower Windband Heavy-gauge aluminum with formed edges for added strength and provides weather resistance. Curb cap(with integral deep spun venturi)is constructed of aluminum and is one-piece for ® Curb Cap a weather-tight fit. Not Internal Conduit A large diameter conduit for installing electrical wiring through the curb cap into the Shown Chase motor compartment. ® Nameplate Permanent embossed aluminum plate for exact model and serial number identification. Galvanized Rigid wire protects the fan discharge from birds and small objects. Birdscreen ® Fan Shroud One-piece, heavy-gauge aluminum with a rolled bead for extra strength directs exhaust air downward. Mounting Holes Curb cap has prepunched mounting holes to ensure correct attachment to the roof. High Wind Construction Features Internal Supports Heavy-gauge supports and bracing are added for additional strength to withstand a load of 75 psf. Reinforced High wind fans include additional reinforcement for maximum strength. Windband Roof Curb High wind-load fans are certified for use with Greenheck model GPFHL, GPFHD, GPF or (page 11) equivalent in high wind applications. Roof curbs ship separate for field installation with attachment details provided. LMGREENHECK Building Value in Air. 6 iw kx 11 ,a,u x 4 13 �. 12 '4 MAn 6 9 w 10 i 8.�+*'. 17 iF LMGREENHECK Building Value in Air. General Clean Air (Figure 1) - Factory Wired from Motor to Disconnect Models G and GB exhaust fans meet the needs of general clean air applications. Tests were conducted to ensure safe, rugged and reliable fans. o00 Due to the varying types of airstreams encountered in commercial ventilation, system designers must be aware of national, state, and local codes and guidelines governing these installations. Consult Figure 1 local code authorities before proceeding with any ventilation project. in. � 8 or 12 in. Wiring by (19 mmJ (203 or 305 mm) • When roofing materials extend to the top of the others curb, roof curbs should be 11/2 inches (3/4 inch on each side) less than the unit curb cap to allow for roofing and flashing. Damper_ Recommended • For recommended duct size, damper size, and 1YAin.—> Duct and F-1'<in. (32 mm) Damper Size (32 mm) roof opening dimensions, refer to the performance Recommended data pages (starting on page 15). R°of opening • Installation must include a means for inspecting, cleaning and servicing the exhaust fan. High Wind, Hurricane and Seismic (Figure 2) • Roofing materials can extend to the top of the Figure 2 v,in.(s mm) curb, roof curbs should be 1 inch (25 mm)total, Fastener o or 1/2 inch (13 mm) on each side, less than the unit 8-24 in. curb cap to allow for roofing and flashing. '/z in.(13 mm) –� From Curb Edge F— (2o3-610GPF mm) From Curb Edge GPF Wiring by Oth are Note:The typical installations shown are recommendations based on national codes.Local authority may supersede these Damper recommendations. Recommended 11A in.(32mm) 0 Duct and F—1Yain.(32 mm) Damper Size Recommended Roof Opening �--� Wheel Rotation Direction of rotation is very critical. Rotation in the wrong direction will result in excessive horsepower, possible motor burnout, and increased noise levels. Check rotation by energizing the unit momentarily.The rotation should be the same as the rotation decals affixed to the unit and is clockwise when viewed from the top of the unit. Clockwise ..�_ 13 LMGREENHECK Building Value in Air. Fan Inlet Connections To ensure proper fan performance, exercise caution in fan placement and connection to the ventilation Good system. Obstructions, transitions, poorly designed elbows, improperly selected dampers, etc., can Good cause reduced performance, excessive noise, and increased mechanical stress. For performance to be as published, the system must provide uniform and stable airflow into the fan. Q Provide uniform airflow at fan inlet to ensure 0 � Q optimum performance. 0 Provide uniform airflow at fan inlet and through the damper to ensure optimum performance. 49 Dampers must open fully. Use motorized dampers in low airflow applications to Ac!—, Poor reduce losses. 0 Avoid sharp turns or entrance conditions that cause uneven flow. Use turning vanes in elbows to reduce adverse effects. ® O 55 R. Model Number Code The model number code system is designed to completely identify the fan.The correct code letters must be specified to designate belt or direct drive.The remainder of the model code is determined by the size and performance GB - 240HP - A - 5 - VGNGD - 1 - 34 - X Motor RPM (Direct Drive only) I A=1725 D=1550 X=UL 705 B=1140 E=1050 F=UL Smoke Configuration J C=860 G=1300 Control Systems G-Direct Drive GB-Belt Drive Fan Size Motor HP Curb Cap Size (inches) 060 through 540 6=1/6 10=1 50=5 4=1/4 15=11/2 75=71/2 Wheel Pressure Level 3=1/3 20=2 100=10 L Performance Revision HP - High Pressure 5=1/2 30=3 150=15 7=3/4 VG =Vari-Green® VG =Vari-Green Drive® International (See CAPS for performance) K=950 RPM J=1475 RPM 14 .,._.. IJGREENHECK Building Value in Air. v VARI-GREEN. 213/4 220 0.9 (552) _._ - .__ ...-__-- ....i-..--------.-.--..- -RPM(Direct Drive)-.. 200 0.8 W RPM Wi Green) j Density 0.075 lb/ft' :.. .._.. V _._.� _...._�.___. Density 1.2 kg/m' 180 0.7 6 -. �L ._..--- --- ----I--- - -..i_-.----_-- a 3 0.6 *14% o 140 (371) I�D m o.5 4 0 :3120 0 N N .. a` 100 L 0.4 4(102) 1U- v 80 .2 0.3 ° 13/444 � c 60 1 0.2 7 (432) 20 Q? 0%, 20 0.1 0 0.0 L� Damper Size=10 x 10(254 x 254) 0 100 200300 400 500 600 Roof Opening=121/2 x 121/2(318x 318) Volume(Cf m) Shroud Thickness=0.064(1.6) Motor Cover Thickness=0.040(1.0) 0 100 200 300 400 500 600 700 soo 900 1000 Curb Cap Thickness=0.064(1.6) Volume (m3/hr) AApproximate Unit Weight=19 Ibs.(9 kg) All dimensions in inches(millimeters).*May be greater depending on motor. Direct Drive RPM AWeight shown is largest cataloged Open Drip-Proof motor. E-1050 RPM G-1300 RPM D-1 550 RPM VG-1725 RPM Direct Motor Fan Static Pressure in Inches wg <,Drive HP RPM 0 01 0,125__ ,O.kS y 0.2 .,.,0 25 , 0 3,. 0.375 _ 0.5_ 0.625 _.....� _�.- a-w ._ _w ,_ CFM 335 268 249 230 189 134 ' VG- E-1/40 t 1050 'BHP ' 0.01 i 0.02 I0 02 0 02 0.02 0 02 1/10 ;Sones 34_'__i._7 3.6 i 3.7 3.9 4.2 CFM 415 _361 348_ 333 j 303 272 1 239 174 'c G 1/30 1300 BHP i 0 02 0_.0_3 0.03 0.03 0.03 0 03 0.03 0.03 W Sones 5.4 5.4 5.4 5.4 5.4 5.5 CFM t 495 450 439 427 404 379 354 j 314 ? 237 D-1/20 1550 ': BHP I 0.04 0 04 0.04 0.05 0 05 6.05 0.05 _'0__.0_6___-_t__06 0. Q Sones 7.3 7.3 7.3 7.3 7.2 7.3 7.3 7.6 CFM 551 511 501 490 469 449 426 392 332 260 1725 BHP 0.05 0 06 0.06 0 06 0 06 0.07 0.07 0.07 0.08 i 0.08 Sones 9.1 9.1 9.1 9.1 9 8.9 8.9 8.9 9.1 9.4 Performance certified is for installation type A:Free inlet,Free outlet.Power rating(BHP)does not include transmission losses.Performance ratings include the effects of a birdscreen.The sound ratings shown are loudness values in hemispherical sones at 5 ft.(1.5 m)in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A:free inlet hemispherical sone levels. 17