Correspondence 0 70 s `� From: Deer)Vora Intertek z ?J To: Klaus Nicolaedis Cc: Robert Danastasio;Sam Doshi Intertek -- G Subject: RE: Unirac SFM module listing Date: Tuesday,July 27,20216:31:09 PM Attachments: imaae003.ono imaae004.ona imaae005.ono Hello Klaus, I can confirm that through your last UL 2703 report update for your Sun Frame Micro Rail PV Mounting System in May 2021, Intertek added the following list of solar module frames for REC PV module manufacturer after evaluation and frame profile comparison. REC Alpha 72 is one of these added modules. Please let me know if you need any other information. REC Solar Twin Peak 2SM 72 Yes NA Apiptoved Alpha Black Yes NA Approved Alpha Yes Manufacturer NA Approved Alpha 72 Yes Twin Peak Similarity NA Approved REC Twin Peak 2S 72 Yes Series Email,and NA Approved Twin Peak 2S 72 XV Yes profile NA Approved Twin Peak 2SM 72 XV Yes Comparison NA A raved N-Peak Yes NA A waved N-Peak Black Yes NA A roved Sunny regards, Deep Vora uitorte k Total Qualtity,AsscsredI 25800 Commercentre Drive Lake Forest, CA 92630 Email: deep.vora(a)intertek.com Mobile: +1 (480) 738 9760 Office: +1 (949) 393 3522 Ext: 11756805 From: Klaus Nicolaedis<Klaus.Nicolaedis@unirac.com> Sent: Monday,July 26, 20217:08 AM To: Deep Vora Intertek<deep.vora@intertek.com> Cc: Robert Danastasio<robert.danastasio@unirac.com> Subject: [External] Unirac SFM module listing Hi Deep, We have an AHJ questioning if the REC Alpha 72 is approved because of how we list the REC modules in the IM. II- Electrical As-Built Diagram i5 -+ .. DESIGNER NOTES: ELECTRICAL NOTES: LOAD BIUE BREAKER IN MSP INTE—R POI ALL CONOUIT TO BE RAN AT LEAST TAA IN ABOVE ROOF SURFACE Am E%POBEO TO B--GRT. (19)REC Solar REC400AA Pura (E)xmA uANT iEi zaC. ENcsouP LOIQ AD OIL' (19)Enph—107PLUS-72-2-US ei x12P PVACDISCONNECr . ua +COMPLIANT �E)2WA/xP LT�ON BOK JUNOFZION BOK aK��OP N)ro P ON JB B,JB-1 (1)CIRCUIT OF IEµOADs P r— 10 MODULES FB NA�N E Eio of Busswc FRw MAm aRPAKER IN)Ba xP I (IB—12P JB-1 I I =Irn. . (1)CIRCUIT OF ------------------- r— r-- ------------ r— 9MODULES — F— xB�a V� I L J I I To —J �(E)GPOUNDING - oEis� $i s <: W ; INTERCONNECTION NOTES 705.12(8)(3)THE FOLLOWING METHOD(S)SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS:(2)WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER SOURCE,ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT , ' CONTAINS LOADS,THE SUM OF 125 PERCENT OF THE POWER-SOURCES)OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUS BAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR. UTILITY COMPANY:Portland General Electric(PGE) PERMIT ISSUER:City of Tigard PV ARRAY Ii PV ARRAY 0 LLJ O PV ARRAY 0 O � c � z , O 911 ,� LL IP L V_ a CB M MAIN DISTRIBUTION RAPID SHUTDOWN AC UTILITY DISCONNECT DISCONNECT SWITCH POWER TO THIS BUILDING IS SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN.