Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (2)
LIABILITY 'The City of Tigard and its employees shall not be Approved planes RECEIVED res orasible for discrepancies shall be on fob site. AERIAL SITE VIEW which may appear herein. JURISDICTION CODES AND STANDARDS CCT 18 2021 I - I GOVERNING CODES CITY OF TIGARD ION ALL WORK SHALL COMPLY WITH BUILDING DIVISION " 2021 OREGON ELECTRICAL SPECIALTY CODE(OESC) 2019 OREGON STRUCTURAL SPECIALTY CODE(OSSC) 2017 OREGON RESIDENTIAL SPECIALTY CODE(ORSC) 2018 INTERNATIONAL FIRECODE(IFC) 2017 OREGON PLUMBING SPECIALTY CODE AND ALL STATE AND LOCAL BUILDING,ELECTRICAL.AND PLUMBING CODES. CONFIDENTIAL-THE INFORMATION a�. HEREIN CONTAINED SHALL NOT BE USED SITE CLASSIFICATION NOTES.OSHA REGULATION OFFICE COPY FOR THE BENEFIT OF ANYONE EXCEPT OCCUPANCY CLASS: SFR ION DEVELOPER.LLC NOR SHE XCIT BE CONSTRUCTION CLASS: V-B DISCLOSED IN WHOLE OR IN PART TO ZONING TYPE: RESIDENTIAL OTHERS OUTSIDE RECIPIENTS :F ORGANIZATION,EXCEPT IN CONNECTION - WITH THE SALE AND USE OF THE I. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. RESPECTIVE EOUIPMENT.WITHOUT THE 2. THIS PROJECT HAS BEEN REVIEWED AND WILL NOT DIRECT CONCENTRATED SOLAR RADIATION OR GLARE WRITTEN PERMISSION OF ION ONTO NEARBY PROPERTIES OR ROADWAYS. DEVE LOPER.LLC. 3. ROOF ATTACHMENTS SHALL BE SPACED NO GREATER THAN 24'ON CENTER IN ANY DIRECTION WHERE 4 k LOCATED WITHIN 3'OF A ROOF EDGE,HIP.EAVE,OR RIDGE OSSC 3111 51 ITEM 3.6 s ELECTRICAL CRITERIA.NOTES NABCEP TEMPERATURE SOURCE: ASTRAL a WEATHER STATION: PORTLAND HILLSBORO CERTIFIED EXTREME MIN.TEMPERATURE: -8 ASHRAE 0.4%HIGH TEMP. 37 PV INSTALLATION PROFESSIONAL s - I. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. SCOTT GURNEY # 2. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED)IN PV-0117719-015866 y. ACCORDANCE WITH NEC ALL ELECTRICAL ION DEVELOPER.LLC 3. PV MODULE CERTIFICATIONS WILL L INCLUDE ULI703.IEC616L6.IEC61]}0. 4801 N UNIVERSITY AVE#900 PROVO.UT 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REOUIREMENTS AND ARE NOT MEANT TO 84604 LIMIT UP-SIZING AS REOUIRED BY FIELD CONDITIONS. 888 781 7074 5. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EOUIPMENT WILL DAVID STANLEY CONRAD ' L DE PROVIDED AS PER SECTION[NEC 110.26]. C-ELECTRICAL CONTRACTOR � R C1524 STRUCTURAL CRITERIA,NOTES DESIGN LOAD STANDARD: A$CE.7-16 WIND EXPOSURE CATEGORY. C WIND SPEED(3-SEC GUST): 96 MPH ;.. GROUND SNOW LOAD.. A ESE �� OF T J.G1 LlW , r DESIGN ROOF SNOW LOAD: 20 PSF T SEISMIC DESIGN CATEGORY: 0 Y $EI$MIG RISK FACTOR II REVIEWED FO CODE COMP IADAM Approved: [ ] W w R- < a OTC: [ ] � z N N A rQ < Y Pcrrnit#:(M5'(ZI�LI —(� SD o OD N Q o Address: )45n D 2" V� Z = w Z oGO Suite #: z r `O oa Y } o oI o Cn SCOPE OF WORK SHEET LIST Da It Se dor DRAWING BY INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM G-I COVER SHEET Existing Roof 81 Ep PROF ENPHASE ENERGY V-2 SITE PLAN(AD. LIB) Attachment Only ��� fss 7.77 KW DC&6.09 KW AC PHOTOVOLTAIC SOLAR ARRAY S-3 ROOF PLAN �NGINEFR /�2 DATE S-4 STRUCTURAL DETAILS Digitally signed by John Q� 45PE 9< 28-08-2021 PV MODULES: (21)SILFAB SOLAR SIL-370 NX MONO PERC S-5 STRUCTURAL CALCULATIONS&NOTES A.Calvert INVERTER(S): (21)ENPHASE IQ7PLUS-72-2-US E-6 ELECTRICAL DETAILS(LINE DIAGRAM) Date:2021.08.31 16:33:56 PROJECT ID E-7 ELECTRICAL CALCULATIONS& NOTES -06'00' DREG 0051`56 E-8 ELECTRICAL LOAD CALCULATIONS(AD. LIB) ROOF TYPE: COMPOSITION SHINGLE E-9 ELECTRICAL LABELS 8,LOCATIONS 8/3 11202 �q�yg SHEET NAME PV MOUNTING HARDWARE: ECOFASTEN CLICKFIT E-10 ELECTRICAL DIRECTORY PLACARD(AD. LIB) EXP:12/31/23 hH A cALv� COVER SHEET CLEFT NUMBER REVISON G-I 0 SITE NOTES: I. ROOF ATTACHMENTS SHALL BE SPACED NO ION GREATER THAN 24"ON CENTER IN ANY DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, HIP,EAVE,OR RIDGE OSSC 3111.5.3 ITEM 3.6 Sealed For CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED ExistingRoof& FOR THE BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE Attachment Only DISCOOLSED N WHOLE OR IN PART HERS OUTSIDE RECIPIENTS TO ORGANIZATION.EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RES PECTIVEL-0IMPMI?"W WITHOUT THE WRITTEN PERMISSION OF ION DEVELOPER LLC. O pe o ° \S�E�NGPNEF� �9NABL F) CERTIFIED o ¢ PIEr PV INSTALLATION ° PROFESSIONAL SCOTT GURNEY Z ( #PV-0117719-015866 W GREG Q RS2 L�q`.)6 rt�N Q� ION DEVELOPER LLC A C PA- 4801 N UN IVERSIT8A VE#900 PROVO.UT N 1J V 8804 8.]81.7074 E- 0 DAVID STAlWEY CONRAD N W C-ELECTRICAL CONTRACTOR EL 3 O _ -. _ C1524 O 8/31/2021 Exp:12/31/21 d O W ° O U Y J GO J W ❑ ❑ ❑ ❑ 'rW W H- Q Z U J RSI 3 CO N o a RO ° rn c r Z CD F J J O w w Z Q O W Q Q O N ° ELI zCK Z Of CE) CN) O GO O M C Z r GO CS OJ Y W } ° Q N n E- OVERHEAD SERVICE LINE DRAWING BY ENPHASE ENERGY DATE SCALE: 3/32" = 1'-0" 28-08-2021 PROJECT ID SYSTEM LEGEND cM) (N)PV COMBwER PANEL S"ox (N)JUNCTION BOX O SUNEYE LOCATION ROOF SECTION ROOF PV MODULE O CRITERIA AND SECTION QTY AZIMUTH PITCH TSRF 005F56 RSI 10 270 6 84% Y (E)UTILITY METER/ LC (N)PV LOAD CENTER A� (N)AC DISCONNECT M FIRE SETBACK SPECIFICATIONS RS2 It 90 6 83% SHEET NAME MAIN SERVICE PANEL (M) (N)PV PRODUCTION (E) ROOF PLAN (E)MAIN SERVICE PANEL METER (N)MICROINVERTER (N)PV MODULE SHEET NUMBER REVISON ®(E)SUBPANEL (N) (N)DC-DC/STRING (M)1(N)DC DISCONNECT S-3 0 NVERTER t RACKING INSTALLATION SCHEDULE AND STRUCTURAL CRITERIA PV MCDULE I O PV RACKING SPAN AREA TAG SPAN P`,�MOUNTING PAIL RACKING. ECOFASTEN CLICKFIT RAIL-PORTRAIT-MODULE ORIENTATION RACKING TYPE: RAIL X-SPACING P-XI 48 IN.O.C.MAX. PORTRAIT STANDOFF: CLICKFIT L-FOOT X-CANTILEAVER P-X2 Ib IN.MAX. ORIENTATION STANDOFF TYPE: L-FOOT 8 FLASHING Y-SPACING P-VI 37.8 IN.MIN.-41.3 IN.MAX. FASTENER. 5/I6"X 3-1/2'ZINC LAG SCREW Y-CANTILEAVER P-Y2 15.5 N.MIN.-I7.I N.MAX. PV ARRAY DETAIL,FRONT VIEW P-X2 P-XI SCALE:3/8'=V-0 CONFIDENTIAL-THE INFORMATION STRUCTURAL RAIL-LANDSCAPE-MODULE ORIENTATION LANDSCAPE HEREIN CONTAINED SHALL NOT BE USED ROOF TYPE: COMPOSITION SHINGLE X-SPACING --XI 48 IN.O.C.MAX. ORIENTATION FOR THE BENEFIT OF ANYONE EXCEPT ION DEVELOPER.LLC NOR SHALL IT ROOF SHEATHING TYPE. I/2'PLYWOOD %-CANTILEAVER L-X2 Ib IN,MAX. DISCLOSED IN WHOLE OR IN PART TOO STRUCTURE TYPE. WOOD TRUSS V-SPACING L-YI 19.7 IN.MIN.-29.5 IN.MAX. L'XZ L-X OTHERS OUTSIDE RECIPIENTS RAFTER SIZE. 2X4 Y-CANTILEAVER L-Y2 5 IN.MIN.-9.8 IN,MAX. ORGANIZATION.EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RAFTER SPACING. 24 RESPECTIVE EQUIPMENT,WITHOUT THE ARRAY PARAMETERS PORTRAIT WRITTEN PERMISSION OF ION DEVELOPER.LLC. TOTAL ROOF AREA(50.FT.) 3139 ORIENTATION TOTAL PV MODULE AREA(SO FT.) 413.7 %PV MODULE ROOF COVERAGE 13% P-Y2 NABCEP VALIDITY OF PERMIT L-Y2 CERTIFIED LANDSCAPE ORIENTATION PV INSTALLATION THE ISSUANCE OF A PERMIT PROFESSIONAL BASED ON CONSTRUCTION SCOTT GU KEY PV ARRAY DETAIL,SIDE VIEW 9 Pv-olvn9-aseae DOCUMENTS AND OTHER SCALE:3is =r-o° ION DEVELOPER LLL A 4801 N UNIVERSITY AVE 9900 PROVO,UT DATA SHALL NOT PREVENT S-4 846°4 888.J81.]074 THE CODE OFFICIAL FROM Z;RACK DAVID STANLEY EDNRAD REQUIRING THE CORRECTION ING ATTACHMENTS TO BE STAGGERED BY SHIFTING EACH C-ELECTRICAL CONTRACTOR SUBSEQUENT ROW OF ATTACHMENTS ONE RAFTER OVER C524 OFERRORS.ORSC 105.4 TO DISTRIBUTE LOAD ACROSS ALL FRAMING MEMBERS UNDER PV ARRAY. Y N J W z CC Z W PV MODULE Lu Q J Sealed For � z N o a CLICKFIT RAIL Existing Roof& Gz Q Y Attachment Only � ( z a o CLICKFIT L-FOOTcy 5° O < p O W DO SPED PROs' z } o o r E)coMP SHINGLE RooF GINF Si W o 01 a DO MEMBRANE Q�(� �G� F9 �2 N -0 r345PE 9r DRAWING BY COMP SHINGLE FLASHING , ENPHASE ENERGY 2} MIN DEPTH OREG DATE 5/16"STAINLESS STEEL LAG L28-0$-ZD21 TH 2-112'MN.EMBEDMENT IN �V�6 Zp1 Q� WITH (E)ROOF RAFTER 8/31/2021 Exp:12/31/21 A, CP``' PROJECTID 005F56 A1 STANDOFF DETAIL SHEET NAE SCALE: 3" = 1'-0" STRUCTURAL DETAILS SHEET NUMBER I REVISOR S-4 0 CONDUCTOR AND RACEWAY SCHEDULE TAG DTY T 1 TOR /V Tq tt SI E-! TYP I TOR 1/V TAG OTY SI -i T DESIGNATOR /V T G TYTYPE DESIGNATOR /V ION 10 (1) 8 AWG THHN/THWN,CU. BLACK(LU 25.4A AC(MAX) 3 (2) 10 AWG THHN/THWN.CU. BLACK(LI) 13.3A AC(MAX) 2 (U 10 AWG 2C,NM-8 WIG.CU. (LI,L2,EGC) 13.3A AC(MAX) I (U 12 AWG 2C,TC-ER,CU. (LI,L2) 13.31 AC(MAX) (U 8 AWG THEN/THWN,CU. RED(L2) 240V AC (2) 10 AWG THEN/THWN.CU. RED(L2) 240V AC FREE AIR (RACEWAY) 240V AC (1) 6 AWG SOLID BARE CU. (EGC) 240V AC (U 10 AWG THEN/THWN,CU. WHITE(N) (1) 10 AWG THHN/THWN,CU. GREEN(EGC) (1) 3/4 IN. EMT OR FREE AIR (RACEWAY) (U 10 AWG THHN/THWN,CU. GREEN(EGC) (1) 3/4 IN. EMT (RACEWAY) (U 3/41N. EMT (RACEWAY) CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ELECTRICAL LINE DIAGRAM (21)SILFAB SOLAR SIL-370 NX MONO PERC PV MODULE(S) ORGANIZATION.EXCEPT IN CONNECTION UL 1703 LISTED WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE (21)ENPHASE 107PLUS-72-2-US MICROINVERTER(S)[24OV] WRITTEN PERMISSION OF ION JUNCTION BOX DEVELOPER.LLC. (E)UTILITY (E)200A MAIN SERVICE PANEL LOAD-SIDE SOURCE CONNECTION ENPHASE IO COMBINER 3 (OPTIONAL-FOR UL 1741 LISTED METER (E)200A/2P MAIN DISCONNECT BUSBAR PLUG-IN TYPE BREAKER (PV CIRCUITS ONLY) CONDUCTOR SPLICE) ,N'_T'ON BOX (NEC 705.12) zooA/2P (N)2OA2P _ w _ _ NABCEP SECONDARY POWER - CIRCUIT CERTIFIED SOURCE(PV OCPD)TO OF 11 CADS BE LOCATED AT N N MODULES PV INSTALLATION OPPOSITE END OF INTEGRAT - BUSBAR FROM PRIMARY 2P OCPD F R PROFESSIONAL SOURCE(MAIN OCPD) 10 ENVOY SCOTT GURNEY (E)LOADS (NEC 705.12) GATEWAY F PV-0117714015866 FUNCTION BOX ION DEVELOPER,LLC 4801 N UNIVERSITY AVE 6400 PROVO,UT 120/240 VAC (N)35A/2P 'N)20A/2P 00 84604 60HZ = CIRCUIT = = 888.781.7074 SINGLE PHASE OF 10 DU UTILITY N MOLES DAVID STANLEY CONRAD SERVICE C-ELECTRICAL CONTRACTOR CI524 • _t R ^"' i.I i E.J.1. 11 (E)GROUNDING - w 1ELECTRODE - �.... Z SYSTEM W W u ' r > J Q -... 3 In N O a Q Y Z CD J O En Z Q o �7_ w w p H ELECTRICAL LINE DIAGRAM NOTES _ J `,i /1 f o = w z Z Of o o Ee o z_ Y n ciO Y W } P Q N n E n CO > N -5 H C n DRAWING BY ENPHASE ENERGY DATE 28-08-2021 PROJECT ID 005F56 SHEET NAME ELEC. LINE DIAG. SHEET NUMBER I REVISON E-6 0 PV SYSTEM ELECTRICAL SPECIFCATIONS AND CALCULATIONS `DESIGN LOCATION AND TEMPERATURES RACEWAY/CONDUCTOR CALCULATIONS ION TEMPERATURE DATA SOURCE ASHRAE MICROINV.TO JUNCTION BOX(I) STATE OREGON MAX INVERTER OUTPUT CIRCUIT CURRENT= 13.3 A AC JURISDICTION CITY OF TIGARD WEATHER STATION PORTLAND HILLSBORO PER NEC 690.8(B)(2)(WITH CORRECTION FACTORS) ASHRAE EXTREME LOW TEMP(°C) -8 CONDUCTOR SIZE/INSULATION/TYPE= 12 AWG 2C,TC-ER.CU. CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED ASHRAE 0.4%HIGH TEMP(°C) 37 CONDUCTOR AMP.RATING @ 90°C= 30 A FOR THE BENEFIT OF ANYONE EXCEPT DESIGNED MAX.SYSTEM VDROP/VRISE 2.00% AMB.TEMP.AMP.CORRECTION= 0.91 ION DEVELOPER,LLC NOR SHALL IT BEDISCLOSED IN WHOLE OR IN PART TO ADJUSTED AMPACITY COMPLIANCE(A)= 27.3 > 13.3 OK OTHERS OUTSIDE RECIPIENTS PV MODULE SPECIFICATIONSSILFAB SOLAR SIL-370 NX MONO PERC RACEWAY SIZE/TYPE= 3/41N. EMT OR FREE AIR WITH THE SALE CAND USE OFEPT IN NTHETION RATED POWER(PMAX)(W) 370 CROSS-SECTIONAL AREA OF CONDUCTOR(S)/CABLE(S)OW-2)= 0.1421N.2 RESPECTIVE EQUIPMENT.WITHOUT THE WRITTEN PERMISSION OF ION MAXIMUM POWER VOLTAGE(VMP) 37.2 CROSS-SECTIONAL AREA OF RACEWAY(IN.'2)= 0.5331N.2 DEVELOPER,LLC. MAXIMUM POWER CURRENT(IMP) 10 %ALLOWABLE RACEWAY FILL(NEC CHAPTER 9,TABLE D= 53% > 27% OK OPEN CIRCUIT VOLTAGE(VOC) 44.8 SHORT CIRCUIT CURRENT(ISC) 10.6 JUNCTION BOX TO JUNCTION BOX(2) NABCE? PMP/VMP TEMP.COEFFICIENT -0.36 MAX INVERTER OUTPUT CIRCUIT CURRENT= 13.3 A AC VOC TEMP.COEFFICIENT -0.28 1 CERTIFIED SERIES FUSE RATING 20 PER NEC 690.8(B)(2)(WITH CORRECTION FACTORS) PV INSTALLATION ADJ.MODULE VOC @ ASHRAE LOW TEMP 48.9 CONDUCTOR SIZE/INSULATION/TYPE= 10 AWG 2C,NM-B W/G,CU. PROFESSIONAL ADJ.MODULE VMP @ ASHRAE 2%AVG.HIGH TEMP 31.3 CONDUCTOR AMP.RATING @60°C= 30A SCOTT GURNEY #OF CONDUCTORS IN RACEWAY CORRECTION= 1.0 x PV-0117719-015866 INVERTER SPECIFICATIONS ENPHASE I07PLUS-72-2-US AMB.TEMP.AMP.CORRECTION= 1.00 ION DEVELOPER,LLC TYPE MICROINVERTER ADJUSTED AMPACITY COMPLIANCE(A)= 30 > 13.3 OK 4801 N UNIVERSITY AVE x900 PROVO,UT MAX.OR 84604 COMMENDED MODULE POWER(W) 440 RACEWAY SIZE/TYPE= FREE AIR 888.781.7074 MAXIMUM INPUT DC OPEN-CIRCUIT VOLTAGE(VOC) 60 MINIMUM START VOLTAGE(V) 22 DAVID STANLEY CONRAD MAXIMUM START VOLTAGE(V) 60 C-ELECTRICAL CONTRACTOR MAXIMUM INPUT CURRENT(ISC)(A) IS 524 CEC PEAK OUTPUT POWER(W) 290 JUNCTION BOX TO COMBINER BOX(3) MAX.CONTINUOUS OUTPUT CURRENT(A) 1,21 MAX INVERTER OUTPUT CIRCUIT CURRENT= 13.3 A AC NOMINAL(L-L)OUTPUT VOLTAGE 240 CEC WEIGHTED EFFICIENCY(%) 97,0% PER NEC 690.8(B)(2)(WITH CORRECTION FACTORS) > CONDUCTOR SIZE/INSULATION/TYPE= 10 AWG THHN/THWN,CU. � SYSTEM ELECTRICAL SPECIFICATIONS CIR I CIR 2 CONDUCTOR AMP.RATING @60°C= 35 A D NUMBER OF MODULES PER CIRCUIT II 10 #OF CONDUCTORS IN RACEWAY CORRECTION= 0.8 Z DC POWER RATING PER CIRCUIT(STC)(W DC) 4070 3700 AMB.TEMP.AMP.CORRECTION= 1.00 w w TOTAL MODULE QUANTITY 21 PV MODULES ADJUSTED AMPACITY COMPLIANCE(A)= 28 > 13.3 OK H- ;> STC DC POWER RATING OF ARRAY 7770W DC RACEWAY SIZE/TYPE= 3/41N. EMT Q p Z v INVERTER OUTPUT CIRCUIT CURRENT(A AC) 13.31 12.1 CROSS-SECTIONAL AREA OF CONDUCTOR(S)/CABLE(S)(IN.-2)= 0.1061N.'2 3 Z N Q CIRCUR OCPD RATING(A) 20 20 CROSS-SECTIONAL AREA OF RACEWAY(IN.'2)= 0.5331N.'2 `a °' a Q Y COMBINED INVERTER CONTINUOUS OUTPUT CURRENT 25.41A AC %ALLOWABLE RACEWAY FILL(NEC CHAPTER 9,TABLE 1)= 40% > 20% OK Z Q o PV POWER PRODUCTION SYSTEM OCPD RATING(X125%) 35A H= w w p MAX.ARRAY AC POWER 609OW AC COMBINER BOX TO MAIN PV OCPD(10) F o cp 2 w Z Z COMBINED INVERTER CONTINUOUS OUTPUT CURRENT= 25.4 A AC O � O Le o AC VOLTAGE RISE CALCULATIONS DIST(FT) COND. VRISE(V) VENOM %VRISE Q VRISE SEC.I(MICRO TO JBOX)' 21.6 12 CU. I.I 241.1 0.48% PER NEC 690.8(B)(2)(WITH CORRECTION FACTORS) UU } U Q 0 Y VRISE SEC.2(JBOX TO COMBINER BOX) 35 10 CU. 1.1 241.1 0.47% CONDUCTOR SIZE/INSULATION/TYPE= 8 AWG THHN/THWN,CU. p 1n r- VRISE SEC.3(COMBINER BOX TO POI) 10 8 CU. 0.4 240.4 0.17% CONDUCTOR AMP.RATING @75°C= 50 A cn 5 ~ w TOTAL VRISE 2.7 242.7 1.11% OK #OF CONDUCTORS IN RACEWAY CORRECTION= 0.8 DRAWING BY CALCULATIONS, LAATIONS, MAX SUB-BRANCH CN2CUIT 512E TO COMPLYWITH PRISE AMB.TEMP.AMP.CORRECTION= 0.88 ENPHASE ENERGY ADJUSTED AMPACITY COMPLIANCE(A)= 35.2 > 25.4 OK DATE RACEWAY SIZE/TYPE= 3/41N. EMT 28-08-2021 CROSS-SECTIONAL AREA OF CONDUCTOR(S)/CABLE(S)(IN.'2)= 0.146 IN.'2 CROSS-SECTIONAL AREA OF RACEWAY(IN.'2)= 0.5331N.'2 PROJECT 1D %ALLOWABLE RACEWAY FILL(NEC CHAPTER 9,TABLE 0= 40% > 27% OK 005F56 SHEET NAME ELECTRICAL CALCS. SHEET NUMBER I REVISON E-7 0 F ELECTRICAL FIELD-APPLIED HAZARD MARKINGS 1 AT EACH PV SYSTEM DISCONNECTING MEANS. F SIGN LOCATED ON OR NO MORE THAN 3 ION ' [NEC 690.54,NEC 690.13(8)] F FT FROM THE RAPID SHUT DOWN [ , DISCONNECT SWITCH[NEC 690.56(C)]. FA'ED AC OJTPUTCURRE@Tj.400A0 N0?JINALDFERATNGACVOITAGE 240 V i-R�s��QED © BE LOCATED AT EACH SERVICE FOR BUILDINGS WITH PV SYSTEMS.TO CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT ❑ FOR PV DISCONNECTING MEANS WHERE ALL WITH RAPD SNUTDM EQUIPMENT LOCATION TO WHICH THE PV ION DEVELOPER.LLE NOR SHALL IT BE B TERMINALS OF THE DISCONNECTING MEANS TIM 11"1`40 f0oNN SYSTEM IS CONNECTED. [NEC DISCLOSED IN WHOLE OR IN PART TO ELECTRIC SHOCK HAZARD MAY BE ENERGIZED IN THE OPEN POSITION. ,�,�alro 690.56(W] OTHERS.TSIDEEXCEPT RECIPIENTS [NEC 690.13(8),NEC 705.22] �r�� ORGANIZATION E%CEPT IN CONNECTION WITH THE SALE AND USE THE TERhONALS ON THE LINE AM LOAD SIDES MAY BE ENEROIZFO WAwvw~ RESPECTIVE EQUIPMENT. PERMISSION SSION WITHOUT THE IN THE OPEN POSITION .. DEVELOPER.LLC. AT EQUIPMENT CONTAINING OVER CURRENT PERMANENT DIRECTORY TO BE LOCATED .I © DEVICES IN CIRCUITS SUPPLYING POWER TOA a A7 MAIN SERVICE EQUIPMENT LOCATION NABCEP BUSBAR OR CONDUCTOR SUPPLIED FORM Mw OtllllYIIOIIOI�muI�Ca� IF ALL ELECTRICAL POWER SOURCE DUAL POWER SUPPLY MULTIPLE SOURCES.[NEC 705.12(C)] DISCONNECTING MEANS (SOLAR ARRAY CERTIFIED IIIu1111106111011N11mtlMNM'tVnM RAPID SHUTDOWN SWITCH)ARE GROUPED •���� �� AND IN LINE OF SITE OF MAIN SERVICE PV INSTALLATION SOURCES:UTILITY GRID AND i101/mAlO1J�9N11�111lO�IE PV SOLAR ELECTRICSYS7EMAlO nrrOT/�Odm01. DISCONNECTING MEANS.[NEC 690.56(0)8 PROFESSIONAL NEC 705.101. SCOTT GURNEY •PV-0117719-015866 PLACED ADJACENT TO PV SYSTEM PLUG-IN ION DEVELOPER.LLC E TYPE BREAKER TO A BUSBAR FOR A LOAD L801 N LNIVERSIT84AV 604#900 PROVO,UT POWER SOURCE SIDE CONNECTION.[NEC 705.1200)(2)] 888.7817074 OUTPUT CONNECTION DAVID STANLEY CONRAD DO NOT RELOCATE THIS C-ELECTRICAL CONTRACTOR OVERCURRENT DEVICE 01524 r FH Y N El © FG� O © J LU :E) E] D❑ 0 F❑ CC Z ,TMITI COMBINER BOk. W W N TFl (E)MAIN SERVICE PANEL E- Q Z U 3 z N O Q O CII Z Q o ODISCONNECT( w w Q GO 3:. 'D I LuOf z V SYSTEM O N � O 0 DISCONNECT(S)TO Z V) N C] Q 7� PV INVERTER — 6 JO Y (N)PV BREAKER OUTPUT CIRCUIT(S) j In j !n 1 1- D- r / DRAWING BY ENPHASE ENERGY DATE 28-08-2021 PROJECT ID 0051`56 ALL CAUTION,WARNING,OR DANGER SIGNS OR LABELS SHALL: SHEET NAME 1, COMPLY WITH ANSI 2535.4-200 STANDARDS. ELECTRICAL LABELS 2. BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN. 3. SHALL BE OF SUFFICEINT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 4. UNLESS OTHERS SPECIFIED MINIMUM TEXT HEIGHT TO BE k(3MM). SHEET NUMBER I REVSDN E-9 0 IDENTIFICATION OF POWER SOURCES A PERMANENT LOCATE OR DIRECTORY TO BE INSTALLED EACH SERVICE EQUIPMENT LOCATION ION DENOTING THE LOCATION OF EACH POWER SOURCE DISCONNECTING MEANS AND SHALL INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. FOR THE BUILDING OR STRUCTURE AND BE GROUPED WITH OTHER PLAQUES OR DIRECTORIES FOR OTHER ON-SITE SOURCES. ALL MARKING TO COMPLY WITH 1IOZ(B).(NEC 705.10) CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT ION DE VELOPER.LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION.EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EDIT PMENT.WITHOUT THE CAUTION : MULTIPLE WRITTEN PERMISSION OF ION DEVELOPER PERMISSION. SOURCES OF POWER . NABCEF POWER TO THIS BUILDING IS SUPPLIED FROM THE CERTIFIED FOLLOWING SOURCES WITH DISCONNECTS LOCATED PV INSTALLATION AS SHOWN: PROFESSIONAL N SCOTT GURNEY #PV-011]]19-015866 wION DEVELOPER.LLC 4801 N UNIVERSITY AVE#900 PROVO.UT w 84604 888.781.]0]4 Q e DAVID STANLEY CONRAD Z �j a C-ELECTRICAL CONTRACTOR ol O w O GO Z n O ZD w (n CC Z rn ❑ ❑ ❑ ❑ Q Z U Lc) 3 � N O Q Q °8 Z 7 H- J Y O W W 0 E- O Q m 3: U D MAIN DISTRIBUTION PV ARRAY CK a Of z UTILITY DISCONNECT RAPID SHUTDOWN AC "' o O Be o DISCONNECT SWITCH Z Y OR 0 r o w > rn a U o j, (D > -) s DRAWING BY ENPHASE ENERGY DATE 28-08-2021 PROJECT ID 0051`56 SHEET NAME ELEC. DIRECTORY i SHEET NUMBER REVISON E-10 0