Report (3) COMcheck Software Version COMcheckWe I r . . Mechanical Compliance Certificate ►` (t 2O2z -00G7, Project Information I I C�5 e Sw 7Z4' AVE RECEIVED Energy Code: 90.1 (2019) Standard an 2 12U22 Project Title: Everbowl TI Location: Tigard, Oregon CITY OF TIGARCJ Climate Zone: 4c Project Type: Alteration BUILDING DIVISIO " Construction Site: Owner/Agent: Designer/Contractor: Iti51 11974 SW 72nd Ave. Suite fr Oregon Mickey Ingalls Tigard, Oregon 97223 Integ Engineering 5120 Franklin Blvd., Suite 1 Eugene, Oregon 97403 9163429556 mickey@integengineering.com Mechanical Systems List QuantitySystem Type & Description 1 [E] HP-13 Split System Heat Pump Heating Mode: Capacity = 40 kBtu/h, Proposed Efficiency = 9.00 HSPF, Required Efficiency = 8.20 HSPF Cooling Mode: Capacity = 36 kBtu/h, Proposed Efficiency = 16.00 SEER, Required Efficiency = 14.00 SEER Proposed Part Load Efficiency = 0.00 , Required Part Load Efficiency = 0.00 SYSTEM VERIFICATION REQUIRED. Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 90.1 (2019) Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Mickey Ingalls - E.I.T. Mickey Ingalls Mi keyyIngalsdb' 07/08/2022 Name-Title Signature Date Project Title: Everbowl TI Report date: 07/08/22 Data filename: Page 1 of 8 COMcheck Software Version COMcheckWeb 1/1/(1(1 Inspection Checklist Energy Code: 90.1 (2019) Standard Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plan Review Complies? Comments/Assumptions & Req.ID 4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met. 6.4.4.2.1, calculations provide all information ❑Does Not 6.7.2 with which compliance can be [PR2]i determined for the mechanical ❑Not Observable systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. 4.2.2, Plans, specifications, and/or ❑Complies 8.4.1.1, calculations provide all information ❑Does Not 8.4.1.2, with which compliance can be 8.7 determined for the electrical systems ❑Not Observable [PR6]2 and equipment and document where ❑Not Applicable exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. 4.2.5.2 Commissioning shall be performed as ❑Complies Exception: Buildings, additions, or alterations with less than [PR5]1 stated in Sections 5.9.2, 6.9.2, 7.9.2, ❑Does Not 10,000 ft2 of conditioned space and combined heating, 8.9.2, 9.9.2, 10.9.2, 11.2(d), and ❑Not Observable cooling, and service water heating equipment totaling less G1.2.1(c). Commissioning must utilize than 960,000 Btu/h in capacity. ASHRAE/IES Standard 202 or other ❑Not Applicable generally accepted engineering standards acceptable to the building official. FPT and verification requirements for commissioning are as stated in Section 4.2.5.1. Commissioning shall document compliance of the building systems, controls, and building envelope with required provisions of this standard. Commissioning requirements shall be incorporated into the construction documents. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Everbowl TI Report date: 07/08/22 Data filename: Page 2 of 8 Section Footing/ Foundation Inspection Complies? Comments/Assumptions & Req.ID 6.4.3.7 Freeze protection and snow/ice ❑Complies Exception: Requirement does not apply. [FO913 melting system sensors for future ❑Does Not connection to controls. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) tjMedium Impact(Tier 2) :3`Low Impact(Tier 3) 1 Project Title: Everbowl TI Report date: 07/08/22 Data filename: Page 3 of 8 Section Mechanical Rough-In i Plans Verified Field Verified # Inspection Value Value Complies? Comments/Assumptions & Req.ID 1 6.4.1.4, HVAC equipment efficiency Efficiency: Efficiency: EComplies See the Mechanical Systems list 6.4.1.5 verified. Non-NAECA HVAC ❑Does Not for values. [ME1]2 equipment labeled as meeting 90.1. ❑Not Observable ....................._.... ❑Not Applicable 6.4.3.4.1 Stair and elevator shaft vents ❑Complies Exception: Requirement 0E3]3 have motorized dampers that ❑Does Not does not apply. automatically close. ❑Not Observable ❑Not Applicable 6.4.3.4.2, Outdoor air and exhaust systems ❑Complies Exception: Gravity dampers 6.4.3.4.3 have motorized dampers that ❑Does Not acceptable in systems with [ME4]3 automatically shut when not in ❑Not Observable outside or exhaust air flow use and meet maximum leakage rates less than 300 cfm rates. Check gravity dampers ❑Not Applicable where dampers are where allowed. interlocked with fan. 6.4.3.4.5 Enclosed parking garage ❑Complies Exception: Requirement [ME39]3 ventilation has automatic ❑Does Not does not apply. contaminant detection and capacity to stage or modulate ['Not Observable fans to 50%or less of design ❑Not Applicable capacity. 6.4.3.4.4 Ventilation fans >0.75 hp have ❑Complies Requirement will be met. [ME5]3 automatic controls to shut off fan ❑Does Not when not required. ❑Not Observable ❑Not Applicable 6.4.3.8 Demand control ventilation ❑Complies Exception: Systems with a [ME6]1 provided for spaces >500 ft2 and ❑Does Not design outdoor airflow less >25 people/1000 ft2 occupant than 1200 cfm. density and served by systems Not Observable with air side economizer, auto ❑Not Applicable modulating outside air damper control, or design airflow >3,000 cfm. 6.5.3.2.1 DX cooling systems >= 75 kBtu/h ❑Complies Exception: Requirement [ME40]2 (>= 65 kBtu/h effective 1/2016) ❑Does Not does not apply. and chilled-water and evaporative cooling fan motor hp ❑Not Observable See the Mechanical Systems list >= 1/4 designed to vary supply ❑Not Applicable for values. fan airflow as a function of load and comply with operational requirements. 6.4.4.1.1 Insulation exposed to weather ❑Complies Requirement will be met. [ME7]3 protected from damage. ❑Does Not Insulation outside of the conditioned space and associated El Not Observable with cooling systems is vapor ❑Not Applicable retardant. 6.4.4.1.2 HVAC ducts and plenums R- R- ❑Complies Requirement will be met. [ME8]2 insulated per Table 6.8.2. Where ❑Does Not ducts or plenums are installed in or under a slab, verification may ❑Not Observable need to occur during Foundation ❑Not Applicable Inspection. 16.4.4.1.3 HVAC piping insulation thickness. in. in. ❑Complies Requirement will be met. ![ME9]2 Where piping is installed in or ❑Does Not under a slab, verification may need to occur during Foundation ❑Not Observable Inspection. ❑Not Applicable 6.4.4.1.4 Thermally ineffective panel ❑Complies Exception: Requirement [ME41]3 surfaces of sensible heating ❑Does Not does not apply. panels have insulation >= R-3.5. ['Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13jLow Impact(Tier 3) 1 Project Title: Everbowl TI Report date: 07/08/22 Data filename: Page 4 of 8 Section Mechanical Rough-In Plans Verified Field Verified # Inspection Value Value Complies? Comments/Assumptions & Req.1D 1 6.4.4.2.1 Ducts and plenums having ❑Complies Requirement will be met. [ME10]z pressure class ratings are Seal ❑Does Not Class A construction. ❑Not Observable ❑Not Applicable 6.8.1-15, Electrically operated DX-DOAS ❑Complies Exception: Requirement 6.8.1-16 units meet requirements per ❑Does Not does not apply. [ME110]2 Tables 6.8.1-15 or 6.8.1-16. ❑Not Observable ❑Not Applicable 6.4.4.2.2 Ductwork operating >3 in. water EComplies Exception: Requirement [ME11]3 column requires air leakage ❑Does Not does not apply. testing. [Not Observable ❑Not Applicable 6.5.2.3 Dehumidification controls ❑Complies Exception: Cooling capacity [ME19]3 provided to prevent reheating, ❑Does Not 40 kBtu/h. recooling, mixing of hot and cold airstreams or concurrent heating ENot Observable and cooling of the same ❑Not Applicable airstream. 6.5.2.4.1 Humidifiers with airstream ❑Complies Exception: Requirement [ME68]3 mounted preheating jackets have ❑Does Not does not apply. preheat auto-shutoff value set to activate when humidification is ❑Not Observable not required. ❑Not Applicable 6.5.2.4.2 Humidification system dispersion ❑Complies Exception: Requirement [ME69]3 tube hot surfaces in the ❑Does Not does not apply. airstreams of ducts or air- handling units insulated >= R ❑Not Observable 0.5. ❑Not Applicable 6.5.2.5 Preheat coils controlled to stop ❑Complies Requirement will be met. [ME70]3 heat output whenever ❑Does Not mechanical cooling, including economizer operation, is active. ['Not Observable ❑Not Applicable 6.5.2.6 Units that provide ventilation air ❑Complies Exception: Requirement [ME106]3 to multiple zones and operate in ❑Does Not does not apply. conjunction with zone heating and cooling systems are ['Not Observable prevented from using heating or ❑Not Applicable heat recovery to warm supply air above 60°F when representative building loads or outdoor air temperature indicate that most zones demand cooling. 6.5.3.3 Multiple zone VAV systems with ❑Complies Exception: Requirement [ME42]3 DDC of individual zone boxes ❑Does Not does not apply. have static pressure setpoint reset controls. ❑Not Observable See the Mechanical Systems list ❑Not Applicable for values. 6.5.4.2 HVAC pumping systems with >= ❑Complies Requirement will be met. [ME25]3 3 control values designed for ❑Does Not variable fluid flow (see section details). ❑Not Observable ❑Not Applicable 6.5.6.1.1 Exhaust Air Energy Recovery for ❑Complies Requirement will be met. [ME56]1 Nontransient Dwelling Units ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Everbowl TI Report date: 07/08/22 Data filename: Page 5 of 8 Section Mechanical Rough-In Plans Verified Field Verified Inspection Value Value Complies? Comments/Assumptions Req.ID 6.5.6.1.2 Exhaust air energy recovery for ❑Complies Exception: Requirements do [ME111]1 spaces other than Nontransient ElDoes Not not apply. dwelling units meeting Tables 6.5.6.1.2-1, and 6.5.6.1.2-2. ❑Not Observable ❑Not Applicable 6.5.7.2.1 Kitchen hoods >5,000 cfm have ❑Complies Exception: Requirement [ME32]2 make up air>=50%of exhaust ❑Does Not does not apply. air volume. ['Not Observable ❑Not Applicable 6.5.3.8 Occupied standy controls for ❑Complies Exception: Requirement [ME112]1 zones serving rooms that are ❑Does Not does not apply. required to have automatic partial OFF or automatic full OFF ENot Observable lighting controls per Section ❑Not Applicable 9.4.1.1 shall meet the following within five minutes of all rooms in that zone entering occupied- standby mode: a)Active heating set point shall be setback at least 1°F, b)Active cooling set point shall be setup at least 1°F and c)All airflow supplied to the zone shall be shut off whenever the space temperature is between the active heating and cooling set points. 6.5.7.2.4 Approved field test used to ❑Complies Exception: Requirement [ME49]3 evaluate design air flow rates ❑Does Not does not apply. and demonstrate proper capture and containment of kitchen ❑Not Observable exhaust systems. ❑Not Applicable 6.5.8.1 Unenclosed spaces that are ❑Complies Exception: Requirement [ME34]2 heated use only radiant heat. ❑Does Not does not apply. ❑Not Observable ❑Not Applicable 6.4.3.9 Heating for vestibules and air ❑Complies Exception: Requirement [ME63]2 curtains with integral heating ❑Does Not does not apply. include automatic controls that shut off the heating system when ❑Not Observable outdoor air temperatures > 45F. ❑Not Applicable Vestibule heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint <= 60F and cooling setpoint >= 80F. 6.5.10 Doors separating conditioned ❑Complies Exception: Building [ME73]3 space from the outdoors have ❑Does Not entrances have automatic controls that disable/reset closing devices. heating and cooling system when ❑Not Observable open. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Everbowl TI Report date: 07/08/22 Data filename: Page 6 of 8 • Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID 8.4.2 At least 50%of all 125 volt 15-and ❑Complies [EL10]2 20-Amp receptacles are controlled by Does Not an automatic control device. ❑Not Observable ❑Not Applicable 8.4.3 New buildings have electrical energy ❑Complies [EL11]2 use measurement devices installed. ❑Does Not Where tenant spaces exist, each tenant is monitored separately. In ['Not Observable buildings with a digital control system ❑Not Applicable the energy use is transmitted to to control system and displayed graphically. 10.4.1 Electric motors meet requirements ❑Complies Requirement will be met. [EL9]2 where applicable. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Everbowl TI Report date: 07/08/22 Data filename: Page 7 of 8 Section # Final Inspection Complies? Comments/Assumptions & Req.ID 6.4.3.1.2 Thermostatic controls have a 5 °F ❑Complies Requirement will be met. [F13}3 deadband. ❑Does Not ❑Not Observable ❑Not Applicable 6.4.3.2 Temperature controls have setpoint ❑Complies Requirement will be met. [F120]3 overlap restrictions. ❑Does Not ❑Not Observable ❑Not Applicable 6.4.3.3.1 HVAC systems equipped with at least ❑Complies Requirement will be met. [F121)3 one automatic shutdown control. ❑Does Not ❑Not Observable ❑Not Applicable 6.4.3.3.2 Setback controls allow automatic ❑Complies Requirement will be met. [FI22]3 restart and temporary operation as ElDoes Not required for maintenance. ❑Not Observable ❑Not Applicable 6.4.3.5 Heat pump controls prevent ❑Complies Exception: Heat pumps regulated by and meeting NAECA [FI5]3 supplemental electric resistance heat ❑Does Not requirements and using internal electric resistance heating. from coming on when not needed. ❑Not Observable ❑Not Applicable 6.4.3.6 When humidification and ❑Complies Requirement will be met. [FI6]3 dehumidification are provided to a ❑Does Not zone, simultaneous operation is prohibited. Humidity control prohibits ❑Not Observable the use of fossil fuel or electricity to ❑Not Applicable produce RH > 30% in the warmest zone humidified and RH < 60% in the coldest zone dehumidified. 6.7.2.1 Furnished HVAC as-built drawings ❑Complies Requirement will be met. [F17]3 submitted within 90 days of system ❑Does Not acceptance. ❑Not Observable ❑Not Applicable 6.7.2.2 Furnished O&M manuals for HVAC ❑Complies Requirement will be met. [F18]3 systems within 90 days of system ❑Does Not acceptance. ❑Not Observable ❑Not Applicable 6.7.2.3 An air and/or hydronic system ❑Complies Exception: Requirement does not apply. [FI9]1 balancing report is provided for HVAC ❑Does Not systems serving zones >5,000 ft2 of conditioned area. ❑Not Observable ❑Not Applicable 10.4.3 Elevators are designed with the ❑Complies Exception: Requirement does not apply. [FI24]2 proper lighting, ventilation power, and ❑Does Not standby mode. ENot Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) T 3JLow Impact(Tier 3)_ 1 Project Title: Everbowl TI Report date: 07/08/22 Data filename: Page 8 of 8