Loading...
Plans (11) Otc F.-4r 6-" (' ENERGY 5506 SE INTERNATIONAL WAY MILWAUKIE.OR 97222 'RECEIVED //�Y�■y.�9■�4 ICHCFBA 167963 6 9INEESN�ER.477.8 V.NET� WA LIC t'.IMAGIEL934PT i_ JUL 1 3 ZOZZ CITY OF TIGARD - r O CITY OF TIGARD REVIEWED FOICOE COMPLIANCE TERRACE GI. E1\1 , R + 'it BUILDING DIVISION Approved: 1 $ ] I-'-'f EAST BUILDING OTC: [ ] Permit#: 6.C C 20 2Z L Address: .1( l6 s./ C.c.� �� 92 KW SOLAR PHOTOVOLTAIC SYSTEM Suite #: 9660 SW GREENBURG RD. TIGARD, OR 97223 By: Date: 7 /q 2Z GENERAL NOTES CODES AND STANDARDS PROJECT INFORMATION SITE MAP E SCOPE OF WORK: APPLICABLE CODES AND STANDARDS: PROJECT OWNER. # ap�"'`n r THIS PROJECT ENTAILS THE INSTALLATION OF SOLAR TERRACE GLENN HOUSING PARTNERS,LP W. rc_ °-- ° g PHOTOVOLTAIC(PV)MODULES,GRID-INTERACTIVE INVERTER 2019 OREGON STRUCTURAL SPECIALTY CODE(OSSC) 208 SW FIRST AVE. ,,; R. AND ASSOCIATED EQUIPMENT TO SUPPLY POWER DIRECTLY TO PORTLAND OR.97204 '"-A„ ,> ,..- 3 - , � r THE EXISTING ELECTRICAL DISTRIBUTION SYSTEM OF THE 2014 OREGON SOLAR INSTALLATION SPECIALTY CODE(OSISC) Y I m I BUILDING. CONTRACTOR 7 ' .. 3 1 '' - '�t"�^'"""" g' ILI NATIONAL ELECTRICAL CODE 2020 ED WALSH CONSTRUCTION ., °,. :.., t V 2905 SW FIRST AVE. ' ', �_.. - ` : ",1 SYSTEM DESCRIPTION: INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS(IEEE) PORTLAND OR.97201 L. a SYSTEM AC CAPACITY IS 75 kWac RATED AT MAXIMUM KENT USHER Z COMBINED OUTPUT AT THE INVERTER(S)TERMINALS. PV NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION(NEMA) PH:503.222.4375 os' `.' - L1J a CAPACITY IS 92 kWdc RATED AT STANDARD TEST CONDITIONS kusher@walshconstruction.com 1 ,, - (STC). NATIONAL FIRE PROTECTION ASSOCIATION(NFPA 70E) ` •'' U m SUBCONTRACTOR: - i [[[[ " >t[ t° Bw Q (200) CANADIAN SOLAR CS3W-460MS,460 WATT PHOTOVOLTAIC UNDERWRITERS'LABORATORIES,INC.(UL) IMAGINE ENERGY jr,•1 g„ � MODULES IEC 61215 CERTIFIED AND UL 1703 LISTED li 5506 SE INTERNATIONAL WAY �: a. x a1 , A A/ WINSULATED CABLE ENGINEERS ASSOCIATION(ICEA) MILWAUKIE OR.97222 ;9 ,_1: t 04 s c -E LL (3)SOLECTRIA PVI25TL-208,25KW INVERTERS LISTED TO UL 1741 ! PAT SCHELLERUP ''� ° AND COMPLYING WITH IEEE 1547. AMERICAN NATIONAL STANDARDS INSTITUTE(ANSI) PH:503.593.2828 7.. ! CCB#167963 '^' (200)AP SMART RSD-SP-PLC DEVICES AMERICAN SOCIETY OF TESTING MATERIALS(ASTM) -£. 8 + SOLAR ARRAY W T' $r .,. 3- �. « „ o- .�.., 1- --1- 4 L MODULE MOUNTING SHALL BE IRONRIDGE XR FLUSH MOUNT i NATIONAL BUREAU OF STANDARDS AUTHORITY HAVING JURISDICTION: ° °s "' SOLAR RACKING COMPLYING WITH UL 2703. CITY OF TIGARD,OREGON � ,r1 7` -<_.n* I. SAFETY ORDERS OF INDUSTRIAL ACCIDENT COMMISSION t INTERCONNECTION: RULES OF THE NATIONAL BOARD OF FIRE UNDERWRITERS ,wµ THIS PV SYSTEM SHALL CONNECT WITH THE EXISTING -- � r ELECTRICAL SYSTEM AT ONE PLACE SPECIFIED AS THE POINT LOCAL ORDINANCES OF THE STATEOF INTERCONNE _ PV BREAKER WITH NCTION,EXI TINGICH t 0 A 208V MA NWILL BEOUGH SERV CEAO0A PANEL LOCAL ORDINANCES OF THE COUNTY OR CITY. DRAWING INDEX VICINITY MA P TERRACE GLEN THE PV SYSTEM IS INTENDED TO OPERATE IN PARALLEL WITH # DESCRIPTION EAST BUILDING THE ELECTRIC UTILITY SERVICE PROVIDER.ANTI-ISLANDING O COVER SHEET �an�iel Park PROJECT DEW:NATION PVO. PROTECTION AND HARMONIC LIMITS SHALL COMPLY WITH UL 92 KW SOLAR PV PROJECT 1741,IEEE 1547 AND IEEE 519. PROJECT ADDRESS PV1.0 SITE PLAN SwN Oman Bi 9660 SW GREENBURG RO. PV2.0 ARRAY PLAN Garden Home " TIGARD,OR 97223 PERMISSION TO OPERATE THE PV SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS ARE OBTAINED PV3.0 ACCESS PLAN E O V. _ g KEN7 USHER INFORMATION FROM THE AUTHORITY HAVING JURISDICTION AND THE PV4.0 ELEVATIONS NYmna®aI P.rY » kasnlahconetruction.com ELECTRIC UTILITY SERVICE PROVIDER. A' `c?` PV4.1 EQUIPMENT MOUNTING $ PROJECT LOCATION 1� PV5.0 ATTACHMENT PLAN SYSTEM PARAMETERS PV6.0 RACKING DETAILS EW Brockman 99 f// 1.HIGH TEMPERATURE. 32°C s.- "`''".,;i, d WENT COVER 2.LOW TEMPERATURE. -8°C PV7.0 WIRING DIAGRAM ! r rNL 3.WIND SPEED:98 MPH swwairED PV8.0 WIRE CALLS z ., REOSIoN'GATE I REANON 4.SNOW LOAD 25 PSF PV9.0 LABELS '�-- 5.WIND EXPOSURE CATEGORY:B 5.ARRAY TILT: 2 .5° PV10.0 STRINGING " ~- 7.ARRAY AZIMUTH.180° PV11.0 DATA SHEETS -- - --- 8.RACKING:IRONRIDGE XR 9.ROOF MATERIAL COMP SHINGLE _ __ __ - --^ 10.ROOF STRUCTURE:ENGINEERED TRUSSES - �� 11.ROOF PITCH:22.5° CCollege a RitY 16.ROOF ORIENTATION:180° BY I 't. HEATH KEARNS A E AR 9yy ❑ J z JUSTISTIN GUADAGNI ' DRAWN ON BEET NUMBER >r 8126/2022 PV0.0 iNTS BGYE ,,,,, VARIES If-- ENERGY (5)STRINGS OF 14 (5)STRINGS OF 14 (4)STRINGS OF 15 55065E97222INTERNATIONAL WAY 92 kW PV ARRAY 55 WSE I ATOz (200)CANADIAN SOLAR CS2W-460MS, P SD3.e7TAases F 50O.n77.e340 460W PV MODULES INFO@IMAGINEENERGYNET GCB K.167%3 (200)AP SMART RSD-SP-PLC DEVICES WA LIGe INTAGIELe39RT #10 PV WIRE IN OPEN AIR ON ROOF< UNDER ARRAY i *WIRE SIZING ON SHEET PV8.0 a\st;,SUPER` DC-1 b o 0 0 o DC-1-8-8-8-8-8 DC-2 b o 08 y, 0 LEGEND - - - - - - El -REPRESENTS LABEL/PLACARD yt OREGON 2 50975 �v L_, L_- J L=, SEE PV9.0 FOR DESCRIPTIONS �RLAVG 1 1 1 1 1 1 1 i 1 1 i 1 1 1 i (N)INVERTER 1 (N)INVERTER 2 (N)INVERTER 3 SOLECTRIA 25KW MPPT 1 MPPT 2 MPPT 3 SOLECTRIA 25KW MPPT 1 MPPT 2 MPPT 3 SOLECTRIA 25KW MPPT 1 MPPT 2 MPPT 3 208 VAC 3PH 208 VAC 3PH 208 VAC 3PH 69.5A OUTPUT i 69.5A OUTPUT I I 69.5A OUTPUT INTEGRATED D INTEGRATED D AC&DC DISCONNECT a AC&DC DISCONNECTINTEGRATED AC&DC DISCONNECT L E E1 INTEGRATED ETHERNET BY INTEGRATED ETHERNET BY INTEGRATED ETHERNET BY TRANSMITTER-PLC OTHERS TRANSMITTER-PLC OTHERS TRANSMITTER-PLC OTHERS (FOR RSD) (FOR RSD) (FOR RSD) p AC-1 b AC-1 8 AC-1 IN 4TH FLOOR< r J I STAIRWELL I 1 z 1 1 LU (N)100A AC-4--- (N)100A AC \ (N)100A AC Q J DISCONNECT 2 DISCONNECT 3 DISCONNECT 4 q1 0 100A FUSE ° ©IH1J 100A FUSE ° ©IH11 100A FUSE ° ©IH1I Z --I— -I I 0 W J 8 AC-2 ate--AC-2 m AC-2 0 m RSD-S-PLC Q/ in (N)GUTTER t r nW w NVENT UD 250 ' Ct DIST.BLOCK I W 1 b AC-3 1 (N)400A AC �q MLE DETAIL DISCONNECT 1 \ RSID ro® M\ [EB1 AC-4 TERRACE GLEN I EAST BUILDING I PROJECT DESaacnON 92 KW SOLAR PV PROJECT PROJECT ADDRESS IN BASEMENT CRRQ SW GRSENB RGR0. ELECTRICAL TIG ROOM E011 3P �l TAGUSHENAraN (E)1600A,MDP 600A 3P E1 503--222--375 208Y/120V,3PH,4W 300A r kusheCQwalahconstructlon.com INTERCONNECTION THROUGH A 300A PV BREAKER WIRING F DIAGRAM Ai B i 1 RCa10N1 DATE I REASON V i TO UTILITY TRANSFORMER 61GNTHED av HEAKEARNS DJUSTRP ITN GUADAGNI 6723/2022 PV7.0 xuE NTS , '. ;r:ir-..2 r ENERGY 5506 SE INTERNATIONAL WAY MILWAUKIE,OR 97222 P 503477 9505 F503.137 NET INFGOIMAGINEENERGY.NET COB 0..167993 WA LIC t:IMAGIEL934PT INVERTER SCHEDULE INVERTER A SOURCE SCHEDULE MODULES MODULE LEVEL RSD DISCONNECT MAKE SOLECTRIA MAKE CANADIAN MAKE AP SMART MODEL PVI 25 TL-208 MODEL CS3W-460MS MODEL RSD-S-PLC MAX OUTPUT CURRENT(A) 15 \NU,SUPER," MAX DC VOLTAGE(VDC) 1000 �' MPPT VOLTAGE RANGE(VDC) 480 POWER(WDC) 460 MAX OUTPUT VOLTAGE(VDC) 80 yj �v,A VOLTAGE RANGE FOR NOMINAL DC VOLTAGE OPEN CIRCUIT(VOC) 49.5 POWER(VDC) 850 DC VOLTAGE MAX POWER(VMP) 41.5 MAX INPUT CURRENT(A) 15 OREGON Z MAX DC CURRENT INPUT(A) 45 DC CURRENT SHORT CIRCUIT(ISC) 11.72 T CORR MAX INPUT VOLTAGE(VDC) 80 ��R LAVG 50975 �v MAX(VOC)-TEMP CORRECTED 53.5 -6 TOTAL PV DC INPUTS 3 MIN(VMP)TEMP CORRECTED 34.9 37 BATTERY INPUT/OUTPUT NA ROOF MINIMUM STRING LENGTH 1 NOMINAL AC VOLTAGE(VAC) 208 VOC TEMP COEFFICIENT(%/DEG C) -0.26% (OPTIMIZERS) CONTINUOUS OUTPUT AC 64 1 PMAX TEMP COEFFICIENT(%/DEG C) -0.34% MAXIMUM STRING LENGTH 20 CURRENT PER PH.(AMPS) NOM.OPERATING CELL TEMP.(DEG C) 41 (OPTIMIZERS) MAXIMUM AC POWER OUTPUT 25 MAXIMUM VOLTAGE PER STRING(VDC) 1000 (kW) SERIES FUSE RATING NA 690.9(A) POWER TOLERANCE(%) +5/-0 690.12(2)(2) COMPLIANCE UL 1741 RAPID SHUT DOWN COMPLIANT YES COMPLIANCE UL 1703 COMPLIANCE UL 1741 DC WIRE CALCS WIRE SECTION TO CHECK CONDUCTOR SPECS STRINGS OUTPUT MAX TEMP MAX.1-WAY CONDUCTOR CONDUCTOR CONDUCTOR(S) ID FROM TO STRING IN CURRENT CURRENT ADJ.VOLTAGE LENGTH(FT.) CONDUCTOR EGC SIZE CONDUCTOR TEMPERATURE VOLTS CONDUCTOR RESISTIVITY CONDUCTOR LENGTH PARALLEL (I) (X 1.25) WiNDOW (L) SIZE(AWG) RATING(C) RATING AMPACITY (R/1000FT) AREA Z DC-1 1.1.1-2.3.1 INVERTER 14 1 14.65 18.3 480 480 150 10 6 PV_WIRE/RHW-2 90 1000 40 1.29 0.057 W DC-2 3.1.1 -3.3.1 INVERTER 15 1 14.65 18.3 480 480 150 10 6 PV_WIRE/RHW-2 90 1000 40 1.29 0.057 /� V C9 Z_ W C] J U =m QN � ADJUSTMENT FACTORS CONDUIT SPECS COMPLIANCE L�.L/ w AMBIENT AMBIENT LOAD CARRYING CONDUIT FILL VOLTAGE ALLOWABLE LARGEST DC Ct ID TEMP(C) HEIGHT ABOVE ADJ ADJUSTMENT CONDUIT CONDUIT CONDUCTORS IN AMPACITY CONDUIT DROP% AMPS(90C ALLOWABLE AMPS CONDUIT ALLOWABLE VOLTAGE VD%=2)(Ix R x L/(1000 x V) ASHRAE.4% ROOF(IN) TEMP TYPE SIZE AREA AMPS(75C) CHECK FILL FILL UJ HIGH TEMP) FACTOR CONDUIT ADJUSTMENT (<2%) DEBATED) DROP DC-1 37.0 >7/8 37.0 0.91 FREE AIR 100% 1.18% 36 35 N/A NA 1.18% DC-2 37.0 >7/8 37.0 0.91 FREE AIR 100% 1.18% 36 35 N/A NA AC WIRE CALCS WIRE SECTION TO CHECK CONDUCTOR SPECS WIRE SIZE OF- TERRACE GLEN EAST BUILDING OUTPUT MAX OVER CURRENT MAX. 1-WAY LOAD CONDUCTOR CONDUCTOR CONDUCTOR PROJECT DESCRIPTION RUN IN CURRENT VOLTAGE LENGTH FT. NEUTRAL EGC CONDUCTORCONDUCTOR(S) 80.98KW SOLAR PV PROJECT ID FROM TO PARALLEL CURRENT (AMPS X PROTECTION (V) PHASE ( ) CARRYING SIZE SIZE CONDUCTOR TYPE TEMPERATURE VOLTS AMPACITY RESISTIVITY 80.96 ADDRESS (I) 1.25) (AMPS) (L) CONDUCTORS RATING(C) RATING (R) 9680 SW GREENBURG RO. IN CONDUIT TIGARD,OR 97223 AC-1 INVERTER(S) AC DISCONNECT(S) 1 64.1 80.1 100 208 3-PH 5 3 6 6 THWN-2/THHN CU 90 600 115 0.254 KENTUSHER"° SD3-2zz = AC-2 AC DISCONNECT(S) °°^ DIST.BLOCK 1 64.1 80.1 100 208 3-PH 5 3 6 6 THWN-2/THHN CU 90 600 115 0.254 kueher 1 h 9Vuction.com AC-3 DIST.BLOCK AC DISCONNECT 1 2 192.3 240.4 250 208 3-PH 125 2/0 4 2 XHHW-MC-AL AL 90 600 300 0.159 AC-4 AC DISCONNECT 1 POI 2 192.3 240.4 250 208 3-PH 10 2/0 4 2 XHHW-MC-AL AL 90 600 300 0.159 WIRE CALCS REN910N f PATE I REASON ADJUSTMENT FACTORS CONDUIT SPECS COMPLIANCE AMBIENT TEMP(C) AMBIENT LOAD CARRYING VOLTAGE ALLOWABLE LARGEST AC "LL" CONDUCTOR ADJ CONDUIT CONDUIT CONDUIT FILL CONDUIT ° ALLOWABLE AMPS CONDUIT ALLOWABLE o _ ID ASHRAE HEIGHT ABOVE ROOF ADJUSTMENT CONDUCTORS IN DROP /o AMPS(90C VOLTAGE VD/o-2 x I x R x L/(1000 x V) _ DEBATED) AMPS(75C) CHECK FILL FILL DROP AREA .4%HIGH TEMP FACTOR TYPE SIZE CONDUIT CORRECTION AREA (<2%) TEMP) PE91°NE➢E, AC-1 0.097 37.0 INSIDE/SHADED NA 0.91 EMT 1.25 3 100% 1.496 0.07% 105 100 26% 40% 1.85% HEATH(EARNS AC-2 0.097 37.0 INSIDE/SHADED NA 0.91 EMT 1.25 3 100% 1.496 0.07% 105 100 26% 40% 'AWN GUADAGNI AC-3 0.222 37.0 INSIDE/SHADED NA 0.91 MC CABLE X 2 100% 1.59% 273 270 53% OR C000 AC-4 0.222 37.0 INSIDE/SHADED NA 0.91 MC CABLE X 2 100% 0.13% 273 270 53% 6/231zo22 PV8.0 NTS .�. A OVERALL SITE DIRECTORY B DUAL POWER SUPPLY B 1 UTILITY PLACARD-PGE B2 UTILITY PLACARD-PAC POWER E,eRIrY (TO BE PLACED AT SERVICE EQUIPMENT,ENTRANCE TO BUILDING/SITE,POI) (TO BE PLACED AT METER BASE,SERVICE (TO BE PLACED AT PGE METER BASE) (TO BE PLACED AT PAC POWER METER BASE) DISCONNECT AND/OR P01) 515500S6 SSE IIN EON ATTI ONAL WAY 5. 9 - P 903.477.8585 F 503A77.8340 ;' ' -' 4'�' _ -. 48 INFOEDIMAGINEENERGVNET CCD is 157963 i , Y l ♦ VW LIC V IMAGIELEDIFE PARALLEL GENERATION ON SITE WARNINGj. n WARNING n WARNING 92 kW SOLAR PV ARRAY DUAL POWER SUPPLY DISCONNECT LOCATIONS AS SHOWN a CUSTOMER-OWNED GENERATION -0w NEDGENERATION SOURCES:UTILITY GRID AND INTERCONNECTED TO PGE.TWO a CUSTOMERINTERCONNECTED TO PAC POWER. PV SOLAR ELECTRIC SYSTEM SOURCES MAY BE PRESENT TWO SOURCES MAY BE PRESENT Fh s L , i . , , , : 4 INVERTERS, AC DISCONNECTS IN 4TH STAIRWELLFLOOR QUANTITY: 2 QUANTITY: 1 QUANTITY: 0 ,p OREGON 2 50975 v r B3 PV SYSTEM DISCONNECT c RAPID SHUTDOWN SWITCH D SOLAR SYSTEM EQUIPED �R LAVc'x" N. >_.. 1 (TO BE PLACED AT AC DISCONNECT SUPPLY SIDE (TO BE PLACED AT RAPID SHUTDOWN INITIATION W/RAPID SHUTDOWN CONNECTION) DEVICE) (TO BE PLACED AT SERVICE DISCONNECT) 5 3 eg 111111111 inn ,8 D8e — 1 1 , SOLAR PV SYSTEM EQUIPPED SOLAR ARRAY MAIN SERVICE PANEL, , PV SYSTEM RAPID SHUTDOWN WITH RAPID SHUTDOWN ON ROOF AC DISCONNECT, / n l DISCONNECT UTILITY METER 1N SWITCH FOR ELECTRIC ET R IN1 4„ TURN RAPID A SOLAR PV SYSTEM THE ow SHUTDOWN SWITCH ON TO SHUTDOWN PV SYSTEM L_ AND REDUCE SHOCKIII I HAZARD IN ARRAY QUANTITY: 1 QUANTITY: 0 QUANTITY: 1 D1 SOLAR SYSTEM EQUIPED E BACKFED BREAKER El OUTPUT CONNECTION E2 AMPACITY OF BUSBAR QUANTITY: 0 W/ RAPID SHUTDOWN (TO BE PANEL)PLACED AT BACKFED BREAKER IN RESIDENCE (TO BE PLACED AT BACKFED BREAKER IN PANEL) (PANEL THAT IS BACKFED OTHER THAN 125%RULE) F SUPPLY SIDE CONNECTION (TO BE PLACED AT SERVICE DISCONNECT) 4' a — SUPPLY SIDE CONNECTIONENT AT CONTAINSZ _ — n WARNING W TH ' i.' CIRCUIT RN NK R WARNING THIS EQUIPMENT FED BY MULTIPLE J CIRCUIT BREAKER SOURCES.TOTAL RATING OF ALL U S IS BACKFED INVERTER OUTPUT CONNECTION OVERCURRENT DEVICES, i ® CAUTION s EXCLUDING MAIN SUPPLY W J DO NOT RELOCATE THIS OVERCURRENT SOLAR POINT OF CONNECTION /, OVERCURRENT DEVICE DEVICE,SHALL NOT EXCEED 0 m CUSTOM AMPACITY OF BUSBAR Q Q w QUANTITY: 0 QUANTITY: 1 QUANTITY: 0 QUANTITY: 0 W I- H PV AC DISCONNECT H1 AC DISCONNECT 1 COMBINER BOX 11 PV/AC AGGREGATE PANEL (TO BE PLACED AT POI AC DISCONNECT) (TO BE PLACED AT AC DISCONNECTS&COMBINER (TO BE PLACED AT AC COMBINER PANEL COVER) (TO BE PLACED AT AC COMBINER INSIDE COVER) QUANTITY: 0 PANEL DISCONNECTS) G ELECTRIC SHOCK HAZARD(TO BE PLACED AT AC P01 AND DC COMBINERS) r _ 3" — 4 — / PV/AC AGGREGATE PANEL TERRACE GLEN PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM DO NOT REMOVE, EAST AC DISCONNECT AC DISCONNECT ti" AC COMBINER BOX td' BUILDING ADD OR RELOCATE PROJECT P G T" ANY CIRCUITS 82 KW SOLAR PV PROJECT WARNING / MAXIMUM AC OPERATING CURRENT XX A MAXIMUM AC OPERATING CURRENT:XX q MAXIMUM AC OPERATING VOLTAGE:XX%V TIGA SW FROM THIS PANEL R O CT SW GGRE% MAXIMUM AC OPERATING VOLTAGE:XXX V ORE72 RD. TIGARD,OR 97223 ELECTRIC SHOCK HAZARD ' W USHER KENT NT U USHEER TERMINALS ON THE LINE AND 503-222-4375 LOAD SIDES MAY BE ENERGIZED l kueherOwelehconetruc9on.com IN THE OPEN POSITION QUANTITY: 1 QUANTITY: 4 QUANTITY: 1 QUANTITY: 0 PV DC DISCONNECT K1 DC DISCONNECT L ENERGY STORAGE M PV POWER SOURCE PLACARDS LABELS/ QUANTITY: 0 K (TO BE PLACED AT MAIN DC DISCONNECTING MEANS) (TO BE PLACED AT DC DISCONNECTS&COMBINERS) SYSTEM DISCONNECT (TO BE PLACED AT ALL PV/DC CONDUIT EVERY 10' REY,a l 0.TE J AC MICRO INVERTERS 1 REASON (TO BE PLACED AT MAIN SERVICE PANEL NEAR a" (TO BE PLACED AT ESS DISCONNECT) AND J BOXES) at BACKFED BREAKER)4 - _ 4. PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM DC DISCONNECT DC DISCONNECT ENERGY STORAGE WARNING: PHOTOVOLTAIC AC MICRO INVERTERS MAX SYSTEM VOLTAGE: XXXVDC MAX SYSTEM VOLTAGE: )0CXVDC SYSTEM DISCONNECT POWER SOURCE SHORT CIRCUIT CURRENT: XX A SHORT CIRCUIT CURRENT: XXA GE3N+NEoev " LOCATED ON ROOF MAX CURRENT DC-TO-DC XXA MAX CURRENTOC-TO-OC XXA HEATH KEARNS UNDER MODULES CONVERTER(S): CONVERTERS>: JUSTIN GUADAGNI P.M ON ETTEET NUMBER QUANTITY: 0 QUANTITY: 3 QUANTITY: 0 QUANTITY: 0 QUANTITY: TBD anEno22 PV9.0 NTS