Loading...
Report (2) Oregon Residential Specialty Code R318.2 MOISTURE CONTENT ACKNOWLEDGEMENT FORM I, S J A, 801,, $40-,,, , am the general contractor or the owner-builder at the following address: Site Address: City: r d YG. Permit#: n, /11$f zo ZI oo/SS Subdivision/Lot #: �oZ7 and/or Map and Tax Lot #: To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R318.2 and OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference]. R318.2 Moisture Content: Prior to the installation of interior finishes, the building official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. Signature: Date: /p/zL General Contractor or Owner-Builder 1:\Building\Form\RES-MoistureContentAcknowledgement_022018 Oregon Residential Specialty Code R408.1 MOISTURE BARRIER ACKNOWLEDGEMENT FORM I, /3,G. SoLezev , am the general contractor or the owner-builder at the following address: Site Address: r. , L. City: r; Permit#: / si zoZI - ootsq Subdivision/Lot#: .72)z and/or Map and Tax Lot#: To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R408.1 Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per Requirement in ORSC Section 408.1 and have taken the following steps to meet this code requirement: TO/The ground surface of the under-floor space is covered by a Class I vapor retarder or other approved materials, with Joints lapped 12 inches at seams and Ft/ Extending up the foundation walls 12 inches. Signature: / Date: io/Ze— General Contractor or Owner-Builder 1:\Building\Form\RE S-MoistureBarrierAcknow ledgement_022018 w . Oregon Residential Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Permit No.: its Jurisdiction: Site Address: /772/7 6k). Fr; Jly L„- Subdivision/Lot#: 7 Z� and/or Map and Tax Lot#: By my signature below, I certify that all of the permanently installed lighting fixtures in the above mentioned building contain high-efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement. (Oregon Residential Specialty Code N1107.2)1 Signature: Date: ‘Xl//Z Z Owner/General Contractor/Authorized Agent Print Name: 15p," f .wi BoL.owl-Dr/ ORSC Section N1107.2. High-efficacy lamps. All permanently installed lighting fixtures shall contain high- efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement. The building official shall be notified in writing at the final inspection that the permanently installed lighting fixtures have met this requirement. Exception: Two permanently installed lighting fixtures are not required to have high-efficacy lamps. 1:\Building\Forms\RES-H igh Efficiencyl,fight i ngAcknow ledgement_022018 Aomininiimmk dAY AO 10.0.4 I..L. K IN`3\J 1a.-". Certificate of Compliance This document certifies that the fiberglass insulation has been installed in conformance with the manufacturer's recommendations and requirements to provide thermal resistance value(s)of: R-value Thickness Coverage Area Ceilings: R-49 X New Construction Vaults/Slopes: R-38 Walls: R-23 O Upgrade Blown in Rim Joist: Floors: Over Garage R-39 BIBS Crawl Vapor Barrier installed Y N Sprinkler Tenting 4 mil Poly Y N Loose-Fill Insulation R- using_bags of insulation to cover All Batts square feet of area at a thickness of 20 inches. Owens Corning'PROPINK°L77 Loosefill Insulation Owens Corning will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value is provided by installing the required number ofbags at a thickness not less than the labeled minimum thickness.Installation of the required number ofbags may yield more than the specified minimum thickness.Failure by the installer to provide both the required bags and at least the minimum thickness will result in lower insulation.R-value. R-VALUE BAGS PER MAXIMUM NET MINIMUM WEIGHT MINUMUM 1000 SQ.FT. COVERAGE PER SQ.FT. THICKNESS To obtain a No.of bags per 1000 sq. Contents of this bag Weight per sq.ft.of Installed insulation thermal resistance ft.of net area: should not cover installed insul.should should not be less (R)of: more than:(sq.ft.) not be less than:(lbs.) than:(in.) 60 28.0 35.8 0.895 20.00 49 21.2 45.0 0.711 16.75 44 19.7 50.7 0.631 15.00 38 16.7 59.9 0.534 13.25 30 13.0 77.0 0.416 10.50 26 11.2 89.6 0.357 9.25 22 9.4 106.3 0.301 8.00 19 8.0 125.0 0.256 7.00 13 5.4 184.6 0.173 4.75 Property Address: 17017 SW Friendly Ln, Tigard, OR. 97224 Lot 27 4/14/22 Rafael Gutierrez Date of Installation Westside Drywall Inc.authorization 6/13/22 Today's Date Building Contractor's Signature Taylor Morrison Company/Customer Name P.O.BOX 99*HUBBARD,OR 97032*(503)620-7036*FAX(503)624-0599*CCB#71044