Report
FPs2d22. _©d 10 / RECEIVED /0120 62r3u&� SimplEx JUN 2 3 2022 TrueAlert Multi-Candela Notification Appliances UL, ULC,CSFM Listed;FM y"'bI r Ion Appliances with Synchronized Flash;Non-Addressable, SmartSync Approved;MEA(NYC) I,I I Y ur I ILM1U Operation Compatible Acceptance* BUIl D{N Features Description Multi-Candela TrueAlert synchronized strobes provide convenient • 4( installation to standard electrical boxes.The enclosure designs are both ai {, impact and vandal resistant and provide a convenient strobe intensity selection.Since each model can be selected for intensity output,on- 4 i site model inventory is minimized and changes encountered during site construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly(including lens) that mounts to a single or double gang,or 4"square standard electrical box.The cover can be quickly removed(a tool is required)and covers are Figure 1: Wall Mount Strobes available separately for color conversion. Ceiling mount strobes install using standard single gang electrical FIRE boxes.Color choice is determined by model number. Strobe Intensity Selection During installation,a selection plug at the back of the housing determines the desired strobe intensity.An attached flag with black Figure 2: Ceiling Mount Strobes letters on a highly visible yellow background allows the selected intensity Visible only(V/O)24 VDC notification appliances with high output to be seen at the side of the strobe lens. xenon strobe,available for wall or ceiling mount: • Intensity is selectable as 15,30,75,or 110 candela with visible Strobe Application Reference selection jumper secured behind strobe housing Proper selection of visible notification is dependent on occupancy, • is with ADA requirements(refer to Installation location,local codes,and proper applications of:the National Fire Alarm Reference,Operation Surface compatibleo Semi-FlushthDWall Mounting) Code(NFPA 72),ANSI A117.1;the appropriate model building code: BOCA,ICBO,or SBCCI;and the application guidelines of the Americans { • Polarized input allows connection to compatible reverse polarity, with Disabilities Act(ADA). supervised notification appliance circuit(NAC) { • Regulated circuit design ensures consistent flash output and provides Synchronized Strobes controlled inrush current Multiple Strobes.When multiple strobes and their reflections can be • Rugged,high impact,flame retardant thermoplastic housings are seen from one location,synchronized flashes reduce the probability available in red or white with clear lens of photo-sensitive reactions as well as the annoyance and possible • Listed to UL 1971 and ULC 5526 distraction of random flashing.These multi-candela strobes are • NEMA 1 rated.See Product Selection for more information synchronized over a two-wire circuit when connected to compatible NACs,to compatible Synchronized Flash Modules,or to SmartSync Strobes provide synchronized flash for use with: Control Modules. • Simplex fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control SmartSync Two-Wire Control • 4009 IDNet NAC Extenders Some applications desire the audible notification appliances to be • Separate strobe Synchronization Modules that are available for Class B capable of being silenced before the alarm condition is reset(on-until- or Class A operation silenced)while the visible notification appliances are kept activated until • Separate SmartSync Control Modules(SCMs)that provide Class B or the alarm condition is reset(on-until-reset).SmartSync operation mode Class A output from conventional NAC inputs provides this function using a single circuit(two-wire operation). Strobe housings provides flexible,easy,and convenient semi- SmartSync Control Sources flush or surface wall mounting: SmartSync two-wire control is available from: • Rear of housing does not extend into box 4006,4007E5 Hybrid,4008,4010,4010ES,4100ES,and 4100U Fire •Wall mount strobes easily mount to single gang,double gang,or 4-inch Alarm Control Panels(refer to individual product data sheets for more square outlet box information) • Ceiling mount strobes mount to single gang boxes 4009 IDNet NAC Extenders(refer to data sheet 54009-0002) SmartSync Control Module(SCM)Model 4905-9938(refer to data sheet Wall mount strobe features: S4905-0003) •Wiring terminals are accessible from the front of the housing providing Additional SmartSync compatible notification appliances include easy access for installation,inspection,and testing separate horns and combination horn/strobe notification appliances. • Covers are available separately to convert housing color For more information refer to installation instructions,579-548. Optional adapters and wire guards: • Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to 2975-9145 boxes • UL listed red wire guards are available for wall or ceiling mount strobes* 54906-0001 Rev.6 01/2020 Simplex Visible Notification Appliances with Synchronized Flash;Non-Addressable, SmartSync Operation Compatible Product Selection Table 1:Multi-Candela Visible Notification Appliances(Strobes) SKU Mounting Housing Color Lettering Description 4906-9101 * Wall Red FIRE(white) 4906-9103* White FIRE(red) 4906-9102* Red FIRE(white) 4906-9104* White FIRE(red) Multi-candela strobe with intensity selectable as: 15,30,75,or 110 Red ALERT(white) candela;synchronized flash rate;SmartSync two-wire control compatible 4906-9114* Ceiling 4906-9115* White ALERT(red) 4906-9116* Red Blank(white) 4906-9117* White Blank(red) *NEMA 1 rated when used with 4095-9931 adaptor plate and 2975-9145 back box. Table 2:Wall Mount Strobe Adapters SKU Description Dimensions 4905-9937 Red 5-3/8"H x 5-1/4"W x 1-5/8"D(136 mm x 133 mm Surface Mount Adapter Skirt;use to cover 1-1/2"(38 mm)deep surface „ x 41 mm)Total depth with strobe=4-3/8 (111 14905-9940 White mounted boxes mm) 14905-9931 ** Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for retrofit, 8-5/16"x 5-3/4"x 0.060"Thick(211 mm x 146 may be mounted vertical or horizontal) mm x 1.5 mm) ,7-7/8"x 5-1/8"x 2-3/4"D(200 mm x 130 mm x 70 2975-9145** Red Mounting Box,requires Adapter Plate 4905-9931 1mm) **NEMA 1 rated. Table 3:Ceiling Mount Strobe Adapter 1SKU 'Description IDimensions Surface Mount Adapter Plate;zinc plated;required for mounting to handy box;not, 4905-9910 14-7/8"x 3-1/8"x 0.060"D(124 mm x 79 mm x 1.5) needed when using 4905-9926 guard Table 4:Synchronization Modules(refer to data sheet 54905-0003 for additional information) 'SKU Description Dimensions 4905-9914 Class B Synchronized Flash Module;epoxy encapsulated with in/out 18 AWG 1-3/8"x 2-7/16"x 13/16"(35 mm x 62 mm x 20 4905-9922 Class A (0.82 mm2)wire leads,rated for 2 A NAC,requires 5 mA for power mm) 4905-9938 SmartSync Control Module with Class B or Class A output;mounts in 4"(102 mm) 4"x 4-1/8"x 1-1/4"D(102 mm x 105 mm x 32 L . square box 1mm) Table 5:Replacement Covers and Guards SKU Description !Dimensions 4905-9992 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D(130 mm x 127 mm x For Wall mount strobes 38 mm) 4905-9993 White cover with red"FIRE"lettering 6-1/16"H x 6-1/16"W x 3-1/8"D(154 mm x 154 .4905-9961* Wall mount Red wire guard with mounting plate,compatible with semi- mm x 79 mm) flush or surface mounted boxes 6-1/8"x 4-3/8"x 2-7/8"deep(156 mm x 111 mm 4905-9926* Ceiling mount Ix 73 mm) L*UL listed by Space Age Electronics Inc. Page 2 S4906-0001 Rev.6 01/2020 9SimplEx Visible Notification Appliances with Synchronized Flash;Non-Addressable, SmartSync Operation Compatible Strobe Specifications Table 6:Wall Mount or Ceiling Mount,Common Specifications Specification Rating Rated Voltage Range Regulated 24 VDC;see Note 1 below I Flash Rate 1 Hz ,Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC !Temperature Range 32°to 122°F(0°to 50°C) 'Humidity Range 10%to 93%,non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/' out wiring Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per Strobe 15 cd 30 cd 75 cd 110 cd Mount Setting(see Note 2 below) 60 mA 94 mA 186 mA 252 mA Reference RMS Currents at 18 VDC 53 mA 84 mA 165 mA 224 mA other voltages 24 VDC 40 mA 63 mA 124 mA 168 mA Housing Dimensions(with lens) 4-3/4"L x 2-5/16"W x 2-5/8"D(121 mm x 75 mm x 67 mm) Maximum RMS Current Rating per Strobe 15 cd 30 cd 75 cd 110 cd Ceiling Setting(see Note 2 below) 75 mA 125 mA 233 mA 316 mA !Mount Reference RMS Currents at 18 VDC 67 mA 111 mA 207 mA 281 mA other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA Note: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971,Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the strobe.Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting /(___—) c__-m c__--0 Mounting is compatible with \ single gang,double gang,and �, I 0 I I 4"(102 mm)square boxes, �° °` l IMPORTANT!WALL MOUNT 1-1/2"(38 mm)deep,by others o o __�oU L/ INSTALLATION HEIGHT REFERENCE Bottom of lens is either even `��/ with,or slightly — Electrical ��+ above bottom box outline Wiring access hole J of compatible\—boxes • Wiring terminals �I� �� i -- k,-.. Mounting Holes: - NFPA 72 requires 80"(2.03 m) 4"square(4) that the entire lens minimum 4• mabRmvII Single gang(2) be not less than Double gang(3) 80"and not greater IL than 96"above the finished floor Transparent housing and lens assembly Intensity selection plug,accessible only from rear of housing; Its I F, Q J ll E factory setting is 15 cd / I11 _- Removable cover Strobe intensity (tool required) viewing slot Page 3 S4906-0001 Rev.6 01/2020 SimplEx Visible Notification Appliances with Synchronized Flash;Non-Addressable, SmartSync Operation Compatible Ceiling Mount Strobe Installation Reference Handy box, 1-1/2" ( 38 mm) deep Single gang box (Wiremold (RACO 650 or equal) or single gang V5744S) 2-1/4" (57 mm) box, 2-1/2" (64 mm) deep (RACO 519 deep, supplied by others or equal) supplied by others Also can be attached to boxes ,r./ mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) CD0 (3 Adapter Plate, required for surface mount with handy box unless using the wire guard oI Ceiling mount strobe be ii' F Ri I I '� Optional wire guard wth mounting plate Strobe intensity 44 0 viewing slot Intensity selection plug, 1 accessible only from rear of lens' housing; factory setting is 15 cd Note: 1. Figure shows 4905-9910 Adaptor Plate. 2. **4905-9926 Wire guard shown Page 4 S4906-0001 Rev.6 01/2020 £3SimplEx Visible Notification Appliances with Synchronized Flash;Non-Addressable, SmartSync Operation Compatible Wall Mount Installation Reference;Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference ®_ Box with Optional Adapter Skirt and Optional Wire Guard ��n Surface mount conduit and 0 -_ box shown for reference ---� 4"(102 mm)square .I= , 1/ 1111 ■1���i�11 11 j box profile, 1-1/2" III,II-IluJ 1 (I (38 mm)deep IIN,i• Iui.i..i.i.i'I O I Optional O r Wire Guard /III 1 MillU___.•1 Strobe \ L� [FORE IIIL.� +�( ter Plate- f = ' Adapter Optional Surface Mount Adapter Skirt, O Optional Wire Guard 1-1/2"deep: Red; White (shown here for reference only, (conduit knockouts Adapter Plate can be used on other mounting options) are provided on all four sides) Figure 3: Wall Mount Installation Reference;Adapter Plate,Guard,and Adapter Skirt Note: Figure 3 shows: • 4905-9931 Adapter Plate • 2975-9145 Box • 4905-9961 Optional Wire Guard • Optional Surface Mount Adapter skirt: - Red:4905-9937 - White:4905-9940 Page 5 S4906-0001 Rev.6 01/2020 f3SimplEx Visible Notification Appliances with Synchronized Flash;Non-Addressable, SmartSync Operation Compatible ©2019 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable,contact your local Autocall product supplier for the latest status.Listings and approvals under Tyco Fire&Security GmbH,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). S4906-0001 Rev.6 01/2020 ®SimpIEx TrueA/ert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSync Operation Audible/Visible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non-Addressable Featuresz :�,: .._. 3SS y.. -at ow- Audible/visible(AN) notification appliances with Ain --" • efficient electronic horn and high output xenon t strobe,available for wall or ceiling mount • Operation is compatible with ADA requirements(refer to important installation information on page 3) • Rugged,high impact,flame retardant thermoplastic housings are available in red or white with clear lens :3FIR E Operates over atwo-wire SmartSync circuit to provide: • Horns that are controlled separately from strobes on the same two-wire circuit • "On-until-silenced"and"on-until-reset"operation on ` + the same two-wire pair • SmartSync horn activation of Temporal pattern,March FIRE Time pattern(at 60 BPM),or on continuously _ • Strobe appliances on the same circuit operating at a _ rt synchronized 1 Hz flash rate • Class B operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM)4905-9938 Wall and Ceiling Mount A/Vs • Class A operation when connected to the 4905-9938 Description SCM or with 4100U series fire alarm control panel NACs Multi-Candela TrueAlert A/Vs with horn and Wall mount A/Vs features: synchronized strobe provide convenient installation to standard electrical boxes.The enclosure designs are • Wiring terminals are accessible from the front of the both impact and vandal resistant and provide a convenient housing providing easy access for installation, strobe intensity selection.Since each model can be inspection,and testing selected for strobe intensity output,on-site model • Covers are available separately to convert housing color inventory is minimized and changes encountered during • Available UL listed sound damper for locations construction can be easily accommodated. requiring attenuation of 5 to 6 dBA(stairwells,small rooms,highly reverberant areas,etc.) Wall mount A/V housings are a one-piece assembly (including lens)that mounts to a single or double gang,or Optional adapters and wire guards: 4"square standard electrical box.The cover can be • Wall mount A/V adapters are available to cover surface quickly removed(a tool is required)and covers are mounted electrical boxes and to adapt to Simplex® available separately for color conversion. 2975-9145 boxes Ceiling mount A/Vs install using standard 4"electrical • UL listed red wire guards are available for wall or boxes.Color choice is determined by model number. ceiling mount A/Vs Visible notification appliance(strobe): Strobe Intensity Selection • 24 VDC xenon strobe;intensity is selectable as 15,30, During installation,a selection plug at the back of the 75,or 110 candela with visible selection jumper secured housing determines the desired strobe intensity.An behind strobe housing attached flag with black letters on a highly visible yellow • UL listed to Standard 1971 background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash output side of the strobe lens. and provides controlled inrush current • This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing Audible notification appliance(horn): 7125-0026:317 for allowable values and/or conditions concerning material presented in this • Low current,24 VDC electronic horn with harmonicallydocument.Accepted for use—City of New York Department of Buildings—MEA35-93E. Refer to page 2 for listing status of wire guards.Additional listings may be applicable; rich sound output suitable for either steady or coded contact your local Simplex product supplier for the latest status.Listings and approvals operation(Temporal or 60 BPM March Time pattern) under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. • UL listed to Standard 464 S4906-0002-6 11/2014 Strobe Application Selection SmartSync Two-Wire Control Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy,location,local codes,and proper applications provide the ability to activate both the horn and strobe on of:the National Fire Alarm Code(NFPA 72),ANSI the same NAC and then allow the horn to be silenced A117.1;the appropriate model building code:BOCA, while the strobe remains flashing.The horn operates as ICBO,or SBCCI;and the application guidelines of the "on-until-silenced"while the strobe operation is Americans with Disabilities Act(ADA). "on-until-reset." Synchronized Strobes SmartSync Control Sources Multiple Strobes.When multiple strobes and their • 4006,4007ES Hybrid,4008,4010,4010ES,4100ES, reflections can be seen from one location,synchronized and 4100U Fire Alarm Control Panels(refer to flashes reduce the probability of photo-sensitive reactions individual product data sheets for more information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender(refer to data sheet random flashing.The multi-candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation • SmartSync Control Module(SCM)4905-9938(refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination Product Selection horn/strobe notification appliances. Multi-Candela ANs Model Mounting Housing Color "FIRE"Lettering Description -I. 4906-9127 Wall Red White 4906-9129 White Red Horn with Multi-Candela Strobe;strobe intensity selectable as: 15,30,75,or 110 candela;operates with SmartSync two-wire 4906-9128 Red White control Ceiling 4906-9130 White Red Wall Mount AN Accessories Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt;use to cover 1-1/2"(38 mm)deep 5 3/8"H x 5 1/4"W x 1-5/8"D 4905-9940 White surface mounted boxes (136 mm x 133 mm x 41 mm) depth with strobe=4-3/8"(111 mm) 4905 9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit,may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box,requires Adapter Plate 4905-9931 7-7/8"x 5-1/8"x 2-3/4"D (200 mm x 130 mm x 70 mm) Optional Sound Damper;package of 20;field installed adhesive backed 4905-9838 horn output attenuator;reduces output 5 to 6 dBA 1-3/4"Diameter(44.5 mm) NOTE:After Sound Damper installation, measure sound level to ensure with 0.31"(8 mm)sound opening compliance with applicable code requirements SmartSync Control Module Model Description Dimensions 4905 9938 SmartSync Control Module with Class B or Class A output;mounts in 4" 4"x 4-1/8"x 1-1/4"D (102 mm)square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount ANs Model Description Dimensions 4905-9994 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D 4905-9995 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions 4905 9961* Wall mount red wire guard with mounting plate,compatible with semi-flush 6-1/16"H x 6-1/16"W x 3-1/8"D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2"x 6 1/8"x 3" (216 mm x 156 mm x 76 mm) 4905-9928* Ceiling Red Adapter Plate,required to mount guard to surface 9"x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension,use to cover 4-3/4"x 6-7/8"x 1-1/2"deep, 4905-9916 Red 1-1/2"deep surface mounted boxes (121 mm x 175 mm x 38 mm) *UL listed by Space Age Electronics Inc. 2 S4906-0002-6 11/2014 A/V Specifications Wall Mount or Ceiling Mount,Common Specifications • Rated Voltage Range UL Listed Rating Regulated 24 DC;see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC • Environmental;Temperature and Humidity 32°to 122°F(0°to 50°C); 10%to 93%,non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep,modulated at 120 Hz rate Horn Output Voltage 16 VDC 24 VDC 33 VDC Ratings Sound Type(see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft(3 m) UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA (see Note 2) Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Strobe Setting(see Note 3 below) 75 mA 116 mA 221 mA 285 mA Mount Reference RMS Currents 18 VDC 67 mA 103 mA 196 mA 253 mA at other voltages 24 VDC 50 mA 77 mA 147 mA 190 mA Housing Dimensions(with lens) 4-3/4 L"x 6-7/8"W x 2-5/8"D(121 mm x 175 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting(see Note 3 below) 86 mA 132 mA 250 mA 320 mA Mount Reference RMS Currents 18 VDC 76 mA 117 mA 222 mA 284 mA at other voltages 24 VDC 57 mA 88 mA 167 mA 213 mA NOTES: 1. "Regulated 24 DC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971,Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the appliance.Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a"fast"setting.Under the same test conditions,coded horn output"peak"sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. 3. Currents are with horn on steady.The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Mounting /�_ `_ (—V Mounting is compatible with 1 0 0 single gang,double gang,and 4"(102 mm)square boxes, C. ( 1 ° ( 1 ri IMPORTANT!WALL MOUNT 1-1/2"(38 mm)deep,by others J o j�° n 1 / (T. / I1 "7 JNSTALLATION HEIGHT REFERENCE Optional 4905-9838 Sound Damper,field attached Bottom of lens to attenuate sound 5 to 6 dBA 1 9 is either even - with,or slightly Electrical o i, - box outline 4�0'ft above bottom Wiring access hole �,- , of compatible il" 0 ' ;, / / boxes Wiring terminals for �i p - I( L°1 )s SmartSync operation llO7 a Mounting Holes. NFPA 72 requires 80"(2.03 m) 4"square(4) single gang(2) that the entire lens minimum RG'i� Double gang(3) be not less than 80"and not greater N than 96"above the Transparent housing finished floor and lens assembly Intensity selection plug,accessible only from rear of housing; Its I , pii pA is factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0002-6 11/2014 Ceiling Mount A/V and Guard Installation Reference Ceiling reference, 4"(102 mm)square box, Optional 4905-9928 Adapter Plate, surface mounted box 1-1/2"(38 mm)minimum depth required for surface mounted electrical box Four mounting clamps included,two each side �� • i!I■I■Irr1■Iilli ilulmill C Ceilin reference, 9 � III�I�1�1�1� �1 A r flush mounted box f Optional 4905-9915/-9916 Adapter, ' recommended for surface mounted box Optional 9 Wiring terminals are Red Wireire Guard , ( IWO) located behind the housing R End View ..... I / — -- Strobe intensity viewing slot� p\ - Intensity selection plug, - accessible only from rear of lens housing;factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt and Optional Wire Guard --7 Surface mount conduit and 0 IIII box shown for reference —•———— 4"(102 mm)square WI � I ��Iil�I�I=I�I�I� ' box profile, 1-1/2"(38 mm)deep1IHI.IrI1IlIII ��_�_ O O Optional !I' �—�� 4905-9961 III SAW IINN I Wire Guard A/V• `-I� o Wif0R - . , FORE ��I- 4905-9931 Adapter PlateitL ' _t Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) TYCO,SIMPLEX,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association(NFPA). ELS i m p 1 EX Tyco Fire Protection Products•Westminster,MA•01441-0001 •USA S4906-0002-6 11/2014 www.simplex-fire.com ©2014 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice.