Loading...
Report (2) COMcheck Software Version 4.1.5.3 OFFICE COP1tr Ali Interior Lighting Compliance Certificate BuP22.z — Project InformationR Energy Code: 2015IECCECEIVED ZNb SIrJ eSV-. Project Title: Lululemon Project Type: Alteration 2 3 201Z CITY OF TIGARD Construction Site: Owner/Agent: BUILDING DIVISION Designer/Contractor: Washington Square Peter Leptuch 9585 SW Washington Sq Road Peter A. Leptuch, P.E. Portland, OR 97223 300 N. Carroll blvd. Suite#200 Denton, TX 76201 (940) 735-5127 pleptuch@yahoo.com Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Retail:Sales Area 7584 1.59 12059 Allowance:Furniture,clothing,cosmetics highlighting/Fix.ID:Track lighting 1 6506(a) 1.40 960(b) Total Allowed Watts= 13019 (a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s)are specified. (b)Allowance is(B x C)or the actual wattage of the fixtures given in Proposed Power section,whichever is less. Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp I Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Retail:Sales Area(7584 sa.ft.) LED 1 copy 1: D5:STRIP LIGHT:Other: 1 9 24 216 LED 6:D6:linear LED:Other: 1 2 20 40 LED 2: FL:STRIP LIGHT:Other: 1 2 11 22 LED 1 copy 1: L4:STRIP LIGHT:Other: 1 1 39 39 LED 1:L8:STRIP LIGHT:Other: 1 10 69 690 LED 3:L2:Surface LED:Other: 1 2 14 28 LED 9:LS2:linear LED:Other: 1 245 4 1102 LED 6 copy 1:P1:linear LED:Other: 1 45 4 198 LED 3 copy 1: R3: LED:Other: 1 4 66 264 LED 5:RF1-S: DN light:Other: 1 8 12 96 LED:RW1:DN light:Other: 1 18 12 216 LED 10:RF4:DN light:Other: 1 8 15 120 Track lighting 1:track: Wattage based on current limiting device capacity 0 0 960 960 Track lighting 2:track: Wattage based on current limiting device capacity 0 0 1080 1080 Track lighting 3:track: Wattage based on current limiting device capacity 0 0 1080 1080 Track lighting 4:track: Wattage based on current limiting device capacity 0 0 1080 1080 Track lighting 5:track: Wattage based on current limiting device capacity 0 0 1080 1080 Track lighting 6:track: Wattage based on current limiting device capacity 0 0 1200 1200 Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\_22.017 - KPA- EV-Lululemon -Washington S Page 1 of 14 Portland, OR\LLL_Portland,OR_2018Comcheck(Passes).cck Total Proposed Watts= 9512 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permi application,The proposed interior lighting systems have been designed to meet the 2015 IECC requirement ' C' c k Ver ' 4.1 .3 and to comply with any applicable mandatory requirements listed in the Inspection Ch: 'is �� Peter A. Leptuch, P.E. Air /�/ d Name-Title Sig at re Dat PROF Fss ��' �NGI NCF9 �(2 /d :5s ,Or A/, A/Za. OREGON o•• U� "lRy 10�Q,�J 1pAML cXPIRES /2/3i/u Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\ (P-2022)\ 22.017-KPA-EV-Lululemon-Washington S Page 2 of 14 Portland, OR\LLL_Portland, OR_2018Co_mcheck(Passes).cck COMcheck Software Version 4.1.5.3 11ic Mechanical Compliance Certificate 111 Project Information Energy Code: 2015 IECC Project Title: Lululemon Location: Portland, Oregon Climate Zone: 4c Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: Washington Square Peter Leptuch 9585 SW Washington Sq Road Peter A. Leptuch, P.E, Portland, OR 97223 300 N. Carroll blvd. Suite #200 Denton,TX 76201 (940) 735-5127 pleptuch@yahoo.com Mechanical Systems List Quantity System Type&Description .� \1 '�t`nil'', 1 HVAC System 1 (Single Zone): ^ '`� NGIN/r 95SU Heating: 1 each-Duct Furnace,Electric,Capacity=4 kBtu/h 2 No minimum efficiency requirement applies '�/ ''r% 1 Cooling: 1 each-Hydronic Coil,Capacity=48 kBtu/h,Unknown Economizer `j'�u No minimum efficiency requirement applies Fan System: None -, 1 OREGON o�ti 1 1 HVAC System 8(Single Zone): 2(j 2 JC Heating: 1 each-Duct Furnace,Electric,Capacity=25 kBtu/h T9 qRY A�Q.� No minimum efficiency requirement applies gDAM k- Cooling: 1 each-Hydronic Coil,Capacity=88 kBtu/h,Unknown Economizer No minimum efficiency requirement applies "XPIRFS:/1/3I/i1i Fan System: None 1 Water Heater 1: Electric Instantaneous Water Heater,Capacity:15 gallons w/Heat Trace Tape Installed Proposed Efficiency:4.80 SL,%/h(if>12 kW),Required Efficiency:2.10 SL,%/h(if>12 kW) Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this d.cument is consistent with the building plans, specifications, and other calculations submitted with this permit appl' atio Th- . oposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck V- o ,.1. -- an., ,#a.• any applicable mandatory requirements listed in the Inspection Checklist. �'� III Peter A. Leptuch, P.E. //tr'/Altit 034/ Name-Title ignature/ Date Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\_22.017- KPA- EV-Lululemon -Washington 5 Page 3 of 14 Portland, OR\LLL_Portland, OR_2018Comcheck(Passes).cck i COMcheck Software Version 4.1.5.3 il Inspection Checklist Energy Code: 2015 IECC IPA Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # i Plan Review Complies? Comments/Assumptions & Req.ID 1 C103.2 Plans,specifications, and/or ❑Complies [PR2]1 calculations provide all information ❑Does Not with which compliance can be determined for the mechanical DNot Observable systems and equipment and DNot Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans,specifications,and/or DComplies ______ [PR3P calculations provide all information ❑Does Not with which compliance can be determined for the service water DNot Observable heating systems and equipment and DNot Applicable document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. C103.2 Plans, specifications,and/or ❑Complies [PR4]i calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\ 22.017-KPA-EV-Lululemon-Washington S Page 4 of 14 Portland, OR\LLL_Portland, OR_2018Comcheck(Passes).cck Section I # j Footing/Foundation Inspection Complies? Comments/Assumptions & Rey.ID L_— C403.2.4. Snow/ice melting system sensors for ❑Complies 5, future connection to controls. Freeze ❑Does Not C403.2.4. protection systems have automatic 6 controls installed. [Not Observable [FO913 ❑Not Applicable Additional Comments/Assumptions: 1 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) i 3 !Low Impact(Tier 3) Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\ (P-2022)\_22.017-KPA- EV- Lululemon-Washington 5 Page 5 of 14 Portland, OR\LLL Portland, OR_2018Comcheck(Passes).cck Section Plumbing Rough-In Inspection Complies? Comments/Assumptions 'Se Re9.1D C404.5, Heated water supply piping conforms OComplies C404.5.1, to pipe length and volume ODoes Not C404.5.2 requirements. Refer to section details. Not Observable [PL6J3 ONot Applicable C404.5, Heated water supply piping conforms OComplies ��4— C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. Not Observable [PL613 ONot Applicable C404.5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details.[PL6]3 ONot Observable ONot Applicable C404.6.1, Automatic time switches installed to OComplies C404.6.2 automatically switch off the ❑Does Not [PL3]1 recirculating hot-water system or heat ❑Not Observable trace. ONot Applicable C404.6.3 Pumps that circulate water between a OComplies �— [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ONot Observable cycle. ONot Applicable C404.6.3 Pumps that circulate water between a OComplies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ONot Observable cycle. ONot Applicable C404.6.3 Pumps that circulate water between a OComplies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to ❑Not Observable <= 5 minutes after end of heating cycle. ONot Applicable C404.7 Water distribution system that pumps OComplies [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source ONot Observable owt demandthrough ar recirculationc ld- aer watersupply system.pipeis a ONot Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps OComplies [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source Not Observable through a cold-water supply pipe is a demand recirculation water system. ONot Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. ['Ti High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\_22.017-KPA-EV-Lululemon-Washington 5 Page 6 of 14 Portland, OR\LLL_Portland, OR_2018Comcheck(Passes).cck Section Plumbing Rough-In Inspection ; Complies? Comments/Assumptions C404.7 Water distribution system that pumps OComplies [PL8j3 water from a heated-water supply ❑Does Not pipe back to the heated-water sourceO Not Observable through a cold-water supply pipe is a demand recirculation water system. LJNot Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F, Additional Comments/Assumptions: j 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\_22.017-KPA-EV-Lululemon-Washington S Page 7 of 14 Portland, OR\LLL_Portland,OR_2018Comcheck(Passes).cck Section # I Mechanical Rough-In Inspection Complies? Comments/Assumptions C402.2.6 Thermally ineffective panel surfaces of❑Complies [ME41)3 sensible heating panels have ❑Does Not insulation >= R-3.5. ONot Observable ONot Applicable C403.2.12 HVAC fan systems at design ❑Complies See the Mechanical Systems list for values. .1 conditions do not exceed allowable ODoes Not [ME65)3 fan system motor nameplate hp or fan :Not Observable system bhp. ONot Applicable C403.2.12 HVAC fan systems at design ❑Complies See the Mechanical Systems list for values. .1 conditions do not exceed allowable ❑Does Not [ME65]3 fan system motor nameplate hp or fan ONot Observable system bhp. ONot Applicable C403.2.12 Fans have efficiency grade(FEG) >= ❑Complies .3 67.The total efficiency of the fan at ❑Does Not (ME117)2 the design point of operation <= 15% ONot Observable of maximum total efficiency of the fan. ONot Applicable C403.2.12 Fans have efficiency grade(FEG) >= ❑Complies .3 67.The total efficiency of the fan at ❑Does Not [ME117]2 the design point of operation <= 15% ONot Observable of maximum total efficiency of the fan. ONot Applicable C403.2.13 Unenclosed spaces that are heated ❑Complies • [ME71)2 use only radiant heat. ❑Does Not ONot Observable ONot Applicable C403.2.3 HVAC equipment efficiency verified. ❑Complies See the Mechanical Systems list for values. [ME55]2 ❑Does Not ONot Observable ONot Applicable C403.2.6. Demand control ventilation provided ❑Complies 1 for spaces>500 ft2 and >25 ❑Does Not [ME59]1 people/1000 ft2 occupant density and :Not Observable served by systems with air side economizer,auto modulating outside ONot Applicable air damper control, or design airflow >3,000 cfm. C403.2.6. Enclosed parking garage ventilation OComplies 2 has automatic contaminant detection ❑Does Not [ME115]3 and capacity to stage or modulate Not Observable fans to 50%or less of design capacity. Not Applicable C403.2.7 Exhaust air energy recovery on ❑Complies [ME57)1 systems meeting Table C403.2.7(1) ❑Does Not and C403.2.7(2). :Not Observable ONot Applicable C403.2.8 Kitchen exhaust systems comply with ❑Complies [ME116]3 replacement air and conditioned ❑Does Not supply air limitations,and satisfy hood :Not Observable rating requirements and maximum exhaust rate criteria. ONot Applicable C403.2.9 HVAC ducts and plenums insulated. ❑Complies [ME6o)2 Where ducts or plenums are installed ❑Does Not in or under a slab,verification may ONot Observable need to occur during Foundation Inspection. ONot Applicable 1 High Impact(Tier 1) 2 (Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\_22.017-KPA-EV-Lululemon-Washington 5 Page 8 of 14 Portland, OR\LLL_Portland, OR_2018Comcheck(Passes).cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.2.9 Ducts and plenums sealed based on ❑Complies [ME10]2 static pressure and location. :Does Not ONot Observable ONot Applicable C403.2.9. Ductwork operating >3 in. water ❑Complies 1.3 column requires air leakage testing. ❑Does Not [ME11)3 :Not Observable ❑Not Applicable C403.2.9. Ductwork operating >3 in.water OComplies 1.3 column requires air leakage testing. ❑Does Not [ME11]3 :Not Observable ONot Applicable C403.4.2. Three-pipe hydronic systems using a ❑Complies 1 common return for hot and chilled ❑Does Not [ME5O]2 water are not used. :Not Observable :Not Applicable C403.4.2. Three-pipe hydronic systems using a DComplies 1 common return for hot and chilled ❑Does Not [ME50]2 water are not used. ONot Observable ONot Applicable C403.4.2. Chilled water plants with multiple ❑Complies 6 chillers have capability to reduce flow ❑Does Not [ME26]3 automatically through the chiller plant :Not Observable when a chiller is shut down. Boiler plants with multiple boilers have the ONot Applicable capability to reduce flow automatically through the boiler plant when a boiler is shut down. C4- 03.4.2. Chilled water plants with multiple ❑Complies 6 chillers have capability to reduce flow ❑Does Not [ME26]3 automatically through the chiller plant ONot Observable when a chiller is shut down. Boiler plants with multiple boilers have the ❑Not Applicable capability to reduce flow automatically through the boiler plant when a boiler is shut down. C4- 03.4.4. Multiple zone VAV systems with DDC ❑Complies See the Mechanical Systems list for values. 6 of individual zone boxes have static ❑Does Not [ME110)3 pressure setpoint reset controls. ONot Observable ONot Applicable C403.4.4. Multiple zone VAV systems with DDC ❑Complies See the Mechanical Systems list for values. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. ONot Observable ONot Applicable C403.4.5 Condenser heat recovery system that ❑Complies [ME31]3 can heat water to 85 4F or provide ❑Does Not 60%of peak heat rejection is installed ONot Observable for preheating of service hot water. ONot Applicable C403.4.5 Condenser heat recovery system that ❑Complies _ [ME31]3 can heat water to 85 2F or provide ❑Does Not 60%of peak heat rejection is installed ['Not observable for preheating of service hot water. DNot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\ 22.017-KPA-EV-Lululemon-Washington S Page 9 of 14 Portland, OR\LLL_Portland,OR_2018Comcheck(Passes).cck Section Mechanical Rough-In Inspection Complies? Comments/Assumptions & Rec.ID L_.---..._._.._._. __.....____.___.........._._........_......_.._._._...__._.._..-....._'r.._.. C408.2.2. Air outlets and zone terminal devices ❑Complies 1 have means for air balancing. ❑Does Not [ME53)3 ❑Not Observable ❑Not Applicable C408.2.2. HVAC hydronic heating and cooling ❑Complies 2 coils have means to balance and have ❑Does Not [ME54]3 pressure test connections. ❑Not Observable ❑Not Applicable C408.2.2. HVAC hydronic heating and cooling ❑Complies 2 coils have means to balance and have ❑Does Not [ME54]3 pressure test connections. ❑Not Observable ❑Not Applicable C403.5, Refrigerated display cases,walk-in ❑Complies C403.5.1, coolers or walk-in freezers served by ❑Does Not C403.5.2 remote compressors and remote Not Observable [ME123]3 condensers not located in a ❑ condensing unit, have fan-powered :Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: I 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\_22.017 -KPA-EV-Lululemon-Washington S Page 10 of 14 Portland, OR\LLL_Portland, OR_2018Comcheck(Passes).cck Section # j Rough-In Electrical Inspection Complies? ( Comments/Assumptions & Req.ID_'__._..._ 1 C405.2.1 Lighting controls installed to uniformly OComplies [EL15]1 reduce the lighting load by at least ❑Does Not 50%. ONot Observable ❑Not Applicable C405.2.1 Occupancy sensors installed in OComplies [EL18J1 required spaces. ODoes Not ['Not Observable ❑Not Applicable C405.2.1, Independent lighting controls installed ❑Complies C405.2.2. per approved lighting plans and all ODoes Not 3 manual controls readily accessible and [EL23]2 visible to occupants. [Not Observable ❑Not Applicable C405.2.2. Automatic controls to shut off all OComplies 1 building lighting installed in all ODoes Not [EL22J2 buildings. ❑Not Observable ❑Not Applicable C405.2.3 Daylight zones provided with OComplies [EL16J2 individual controls that control the ODoes Not lights independent of general area lighting. ❑Not Observable ❑Not Applicable C405.2.3, Primary sidelighted areas are OComplies C405,2.3. equipped with required lighting ODoes Not 1, controls. :Not Observable C405.2.3. 2 ❑Not Applicable [EL2011 C405.2.3, Enclosed spaces with daylight area OComplies C405.2.3. under skylights and rooftop monitors ODoes Not 1, are equipped with required lighting C405.2.3. controls. ❑Not Observable 3 ❑Not Applicable [EL21]1 C405,2.4 Separate lighting control devices for OComplies _~— [EL4]1 specific uses installed per approved ODoes Not lighting plans. ['Not Observable ❑Not Applicable C405.2.4 Additional interior lighting power OComplies [EL8J1 allowed for special functions per the ODoes Not approved lighting plans and is :Not Observable automatically controlled and separated from general lighting. ❑Not Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies [EL6J1 face. ODoes Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) _ 2 Medium Impact(Tier 2) 1 3 Low Impact(Tier 3) Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\ 22.017- KPA- EV-Lululemon-Washington S Page 11 of 14 Portland, OR\LLL Portland,OR_2018Comcheck(Passes).cck Section I # I 1 Final Inspection Complies? Comments/Assumptions C303.3, Furnished O&M instructions for ❑Complies C408.2.5. systems and equipment to the ODoes Not 2 building owner or designated [FI17]3 representative. ONot Observable ONot Applicable C303.3, Furnished O&M manuals for HVAC DComplies - �� C408.2.5. systems within 90 days of system ❑Does Not 3 acceptance. [FI8]3 :Not Observable ONot Applicable C403.2.2 HVAC systems and equipment ❑Complies [FI27]3 capacity does not exceed calculated ❑Does Not loads. ONot Observable _ ONot Applicable C403.2.4. Heating and cooling to each zone is ❑Complies - 1 controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device per installed ONot Observable humidification/dehumidification ONot Applicable system. C403.2.4. Heating and cooling to each zone is ❑Complies _____ 1 controlled by a thermostat control. ❑Does Not [F147)3 Minimum one humidity control device ['Not Observable per installed r humidification/dehumidification ONot Applicable system. C403.2.4. Thermostatic controls have a 5 °F ❑Complies 1.2 deadband. ❑Does Not , [FI38]3 :Not Observable I [Not Applicable C403.2.4. Temperature controls have setpoint ❑Complies 1.3 overlap restrictions. ❑Does Not [FI20]3 ONot Observable ONot Applicable C403.2.4. Each zone equipped with setback ❑Complies 2 controls using automatic time clock or El—Does Not [FI39]3 programmable control system. :Not Observable DNot Applicable C403.2.4. Automatic Controls: Setback to 55°F OComplies 2.1, (heat)and 85°F(cool); 7-day clock, 2- ❑Does Not C403.2.4. hour occupant override, 10-hour Not Observable 2.2[F 40]3 backup ONot Applicable • C404.3 Heat traps installed on supply and ❑Complies [FI11]3 discharge piping of non-circulating ❑Does Not systems. ❑Not Observable :Not Applicable C404.4 All piping insulated in accordance with ❑Complies [F125J2 section details and Table C403.2.10. ❑Does Not ONot Observable ONot Applicable 1 1 High Impact(Tier 1) 2l Medium Impact(Tier 2) 13 I Low Impact(Tier 3) I Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\ 22.017-KPA-EV- Lululemon-Washington S Page 12 of 14 Portland, OR\LLL_Portland, OR_2018Comcheck(Passes).cck Section Final Inspection Complies? Comments/Assumptions C405.4.1 Interior installed lamp and fixture OComplies See the Interior Lighting fixture schedule for values. (FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts ONot Observable are less than or equal to allowed ❑Not Applicable watts. C408.2.1 Commissioning plan developed by OComplies [FI28]1 registered design professional or ODoes Not approved agency. ONot Observable ONot Applicable C408.2.3. HVAC equipment has been tested to OComplies 1 ensure proper operation. ODoes Not [Fl31]1 ONot Observable ONot Applicable C408.2.3 HVAC control systems have been OComplies 2 tested to ensure proper operation, ODoes Not [FI10)1 calibration and adjustment of controls. ONot Observable ONot Applicable C408.2.4 Preliminary commissioning report ❑Complies [FI29)1 completed and certified by registered ODoes Not design professional or approved agency. ONot Observable ONot Applicable C408.2.5. Furnished HVAC as-built drawings -Li-Complies 1 submitted within 90 days of system ODoes Not [FI7)3 acceptance. ONot Observable ONot Applicable C408.2.5. Furnished as-built drawings for ❑Complies 1 electric power systems within 90 days ODoes Not [FI16]3 of system acceptance. ONot Observable :Not Applicable C408.2.5. An air and/or hydronic system OComplies 3 balancing report is provided for HVAC DDoes Not [FI43]1 systems. ONot Observable ONot Applicable _ C408.2.5. Final commissioning report due to OComplies 4 building owner within 90 days of ODoes Not [FI30]1 receipt of certificate of occupancy. ONot Observable ONot Applicable C408.3 Lighting systems have been tested to OComplies [FI33]1 ensure proper calibration, adjustment, ODoes Not programming, and operation. ONot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) j 3 i Low Impact(Tier 3) Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\_22.017-KPA- EV-Lululemon-Washington S Page 13 of 14 Portland, OR\LLL_Portland, OR_2018Comcheck(Passes).cck w Project Title: Lululemon Report date: 03/11/22 Data filename: C:\Users\Peter A Leptuch P E\Dropbox\_(P-2022)\_22.017-KPA- EV• Lululemon -Washington S Page 14 of 14 Portland, OR\LLL_Portland, OR_2018Comcheck (Passes).cck