Loading...
Report ' COMcheck Software Version COMcheckWeb (6 Interior Lighting Compliance Certificate c2022 r603 . 44 EL RG � C E I V E DProject Information SvA / PAC( 0 Energy Code: 2018 IECC ' • JUN 9 2022 Project Title: Tigard -Trader Joe's j al Y OF TIGARD Project Type: New Construction �: BUILDING DIVISION Construction Site: Owner/Agent: Designer/Contractor: Additional Efficiency Package(s) Credits: 1.0 Required 0.0 Proposed Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed (ft2) Watts /ft2 Watts 1-Multifamily 16152 0.68 10983 Total Allowed Watts = 10983 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp /Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. 1-Multifamily LED: A: 2'X4' RECESSED TROFFER: Other: 1 147 49 7203 LED: B: 4' SUSPENDED: Other: 1 7 38 266 LED: C: 2'X2' RECESSED TROFFER: Other: 1 17 29 493 LED: D: 4' STRIP: Other: 1 13 34 442 LED: X: EXIT SIGN: Other: 1 6 1 6 LED: T: 8'TRACK: Other: 1 1 600 600 Total Proposed Watts = 9010 Interior Lighting PASSES: Design 18% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. C,r�`J �' l ���"''� Tobin Bateen - Electrical / ' '`--- 05/22/2022 Name-Title Signature Date Project Title: Tigard -Trader Joe's Report date: 05/02/22 Data filename: Page 1 of 6 COMcheck Software Version COMcheckWeb (41 II Exterior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Tigard -Trader Joe's Project Type: New Construction Exterior Lighting Zone 2 (Residential mixed use area (LZ2)) Construction Site: Owner/Agent: Designer/Contractor: Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts / Wattage (B X C) Entry canopy 984 ft2 0.25 Yes 246 Total Tradable Watts (a) = 246 Total Allowed Watts= 246 Total Allowed Supplemental Watts (b) = 400 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 400 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description / Lamp /Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. Entry canopy (984 ft2): Tradable Wattage LED: F: 6" CAN: Other: 1 14 44 616 Total Tradable Proposed Watts = 616 Exterior Lighting PASSES: Design 5% better than code Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Tobin Bateen - Electrical 7 ,(J- 4 J3G 05/22/2022 Name -Title Signature Date Project Title: Tigard -Trader Joe's Report date: 05/02/22 Data filename: Page 2 of 6 COMcheck Software Version COMcheckWeb rift Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID — — — — — C103.2 Plans, specifications, and/or ❑Complies [PR4]1 calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment '❑Not Applicable , and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. C103.2 Plans, specifications, and/or ❑Complies [PR8]1 calculations provide all information '❑Does Not with which compliance can be determined for the exterior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: [1 High Impact(Tier 1) T2 LMedium Impact (Tier 2) ; 3 Low Impact(Tier 3) i Project Title: Tigard -Trader Joe's Report date: 05/02/22 Data filename: Page 3 of 6 Section Rough-In Electrical Inspection Complies? Comments/Assumptions C405.2.2. Spaces required to have light- ❑Complies 2 reduction controls have a manual ❑Does Not [EL22]1 control that allows the occupant to reduce the connected lighting load in ❑Not Observable a reasonably uniform illumination ❑Not Applicable pattern >= 50 percent. C405.2.1, Occupancy sensors installed in .❑Complies C405.2.1. classrooms/lecture/training rooms, ,❑Does Not 1 conference/meeting/multipurpose [EL18]1 rooms, copy/print rooms, ❑Not Observable lounges/breakrooms, enclosed offices, ❑Not Applicable open plan office areas, restrooms, storage rooms, locker rooms, warehouse storage areas, and other spaces <= 300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. C405.2.1. Occupancy sensors control function in ❑Complies 2 warehouses: In warehouses, the liElDoes Not [EL19]1 lighting in aisleways and open areas is Observable controlled with occupant sensors that automatically reduce lighting power ❑Not Applicable by 50%or more when the areas are unoccupied.The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. C405.2.1 Occupant sensor control function in ❑Complies 3 open plan office areas: Occupant ❑Does Not [EL20]1 sensor controls in open office spaces >= 300 sq.ft. have controls 1) ❑Not Observable configured so that general lighting can ❑Not Applicable be controlled separately in control zones with floor areas <= 600 sq.ft. within the space, 2) automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space, 3) are configured so that general lighting power in each control zone is reduced by >= 80%of the full zone general lighting power within 20 minutes of all occupants leaving that control zone, and 4) are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected. C405.2.2, Each area not served by occupancy ❑Complies C405.2.2. sensors(per C405.2.1) have time- ❑Does Not 1, switch controls and functions detailed C405.2.2. in sections C405.2.2.1 and C405.2.2.2. ❑Not Observable 2 ❑Not Applicable [EL21]2 I_1 I High Impact(Tier 1) [ 2 Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Tigard -Trader Joe's Report date: 05/02/22 Data filename: Page 4 of 6 , Section Rough In Electrical Inspection I Complies? Comments/Assumptions & Req.ID_ C405.2.3, Daylight zones provided with ❑Complies C405.2.3. individual controls that control the ❑Does Not 1, lights independent of general area C405.2.3. lighting. See code section C405.2.3 ENot Observable 2 Daylight-responsive controls for ENot Applicable [EL2312 applicable spaces, C405.2.3.1 Daylight responsive control function and section C405.2.3.2 Sidelit zone. C405.2.4 Separate lighting control devices for ❑Complies [EL26]1 specific uses installed per approved ❑Does Not lighting plans. [Not Observable ENot Applicable C405.2.4 Additional interior lighting power ❑Complies [EL27]1 allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and Not Observable separated from general lighting. ❑Not Applicable C405.2.5 .Manual controls required by the ❑Complies [EL28]ni0 energy code are in a location with ❑Does Not ready access to occupants and located where the controlled lights are ❑Not Observable visible, or identify the area served and ENot Applicable their status. C405.2.6 Automatic lighting controls for exterior ❑Complies [EL30]ni° lighting installed. Controls will be ❑Does Not daylight controlled, set based on business operation time-of-day, or ENot Observable reduce connected lighting > 30% ENot Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies [EL6]1 face. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: rl High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) — Project Title: Tigard -Trader Joe's Report date: 05/02/22 Data filename: Page 5 of 6 Section # Final Inspection 1 Complies? Comments/Assumptions & Req.Id C303.3, Furnished O&M instructions for ❑Complies C408.2.5. systems and equipment to the ❑Does Not 2 building owner or designated [FI17]3 representative. ❑Not Observable ENot Applicable C405.4.1 Interior installed lamp and fixture EComplies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts plot Observable are less than or equal to allowed ,❑Not Applicable watts. C405.5.1 Exterior lighting power is consistent ❑Complies See the Exterior Lighting fixture schedule for values. [FI19ji with what is shown on the approved EDoes Not lighting plans, demonstrating proposed watts are less than or equal ENot Observable to allowed watts. ENot Applicable C408.2.5. Furnished as-built drawings for ❑Complies 1 electric power systems within 90 days ElDoes Not [F116)3 of system acceptance. ❑Not Observable ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies [F133]1 ensure proper calibration, adjustment, ❑Does Not programming, and operation. ❑Not Observable ENot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) i 3 Low Impact(Tier 3) Project Title: Tigard -Trader Joe's Report date: 05/02/22 Data filename: Page 6 of 6