Loading...
Report RECEIVED OFFICE Copy Ol 2022 . , CITY OF TIGARD BUILDING DIVISION / 1 No' • • ` `4' s W VAT T FIRE PROTECTION , INC. 9095 S.W. Burnham Tigard, OR 97223 OREGON STATE TREASURY 16290 SW UPPER BOONES FERRY RD TIGARD, OR 97224 FP3 2a22- 1 `4.71 FIRE PROTECTION EQUIPMENT SUBMITTAL 14L'1I1LJ Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers - ,, :' Description described herein must be installed and .. ; .: maintained in compliance with this doc- The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable Upright(TY313) and Pendent (TY323) standards of the National Fire Protec- Sprinklers described in this data sheet tion Association,in addition to the stan- -- are quick response,standard coverage, dards of any other authorities having _ . decorative 3 mm glass bulb-type spray jurisdiction. Failure to do so may impair ---, sprinklers designed for use in light or the performance of these devices. .,,,--. ordinary hazard,commercial occupan- cies such as banks, hotels, and shop- The owner is responsible for maintain- ping malls. ing their fire protection system and devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. finished ceiling.This recessed pendent sprinkler uses one of the following: Sprinkler • A two-piece Style 15 Recessed Escutcheon with recessed adjust- Identification C ment up to 5/8 inch (15,9 mm) from .,a the flush pendent position. Number (SIN) • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2"NPTv. the flush pendent position. The adjustment provided by the Technical Temperature Rating Escutcheon reduces the p accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Intermediate level versions of Series Approvals 2105°F(790°F (79°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°°F(141 C) Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics ' 175 psi (12.1 bar) Frame Bronze 250 psi(17.2 bar)° Button Brass/Copper °The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi112(80,6 LPM/bar1/2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON se/. \ 0/ • \ i ,,_-.._—__—_—_- 5 �.9 7/16" (11,1 mm) I 111 4 I NOMINAL 2"11 MAKE IN (508 mm)2 7a ' 2" �,Il�/ 1-3/83 Lp (50,8 mm) (34,9 mm) ENCHr$. ! / i jATS 1/2" NPT** DEFLECTOR* 2-7/8" (73,0 mm)DIA. - CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE L, Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright (TY313) and Pendent (TY323) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. ^� glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally, a small air WRENCH bub- Criteria ble should be present. The diameter of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch (1,6 mm)for the 135°F(57°C)and Upright (TY313) and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) Sprinklers are intended for fire protec- temperature ratings. /�1 tion systems designed in accordance with the standard installation rules rec- A leak-tight 1/2 inch NPT sprinkler joint ill ognized by the applicable Listing or should be obtained by applying a min- Approval agency (such as, UL Listing imum to maximum torque of 7 to 14 �� t is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels %we 13, and FM Approval is based on the of torque can distort the sprinkler Inlet requirements of FM's Loss Prevention with consequent leakage or impairment PUSH WRENCH Data Sheets).Only the Style 15 or Style of the sprinkler. IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent installations. insufficient adjustment in the Escutch- WITH SPRINKLER WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3.Tighten the sprinkler into the 2-7/8" DIA. sprinkler fitting using only the W-Type (73,0 mm) - 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1, apply the W-Type 6 2-1/4" DIA. Sprinkler Wrench to the wrench flats. FACE OF ~ (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8" (15,9 mm) Recessed Pendent Sprinklers l , _, ; FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" Sprinklers must be installed in accor- (9,5±7,9 mm) 'V 7 dance with the following instructions. } / �� Step A.After installing the Style 15 or MOUNTING �-1, 1/8 Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread --�_�-- sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE sprinkler fitting. 3/4" (19,1 mm) FIGURE 4 Step B. Tighten the sprinkler into the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) sprinkler fitting using only the W-Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench (Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8" DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER 257 2' DIA. m - ishing, slide on the Style 15 or Style 20 FITTING ( ) Closure over the Series TY-FRB Sprin- 5/16±1/4" 1/2"(12,7 mm) kler and push the Closure over the (7,9±6,4 mm) Mounting Plate until its flange comes in FLUSH contact with the ceiling. 11�� �I Care and t MOUNTING 1/8 J Maintenance SURFACE (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, Upright (TY313) and Pendent (TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated, should be replaced regarding any questions. if they cannot be completely cleaned Absence of the outer piece of an Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- ' operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage,or the like, must be replaced. with a feather duster; otherwise, non- Also, replace any sprinkler that has a • operation in the event of a fire or inad cracked bulb or that has lost liquid from vertent operation may result. its bulb.(Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 3 PURE WHITE(RAL9010)°° 155 155°F(68°C) POLYESTER 371 5.6K PENDENT(1/2"NPT) TY323 q SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER 'Use suffix"I"for ISO 7-1 connection; 9 CHROME PLATED 200 200°F(93°C) for example,77-370-4-175-I "Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify)tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with (specify*)finish, P/N(specify`) Specify: Style 20 Recessed Escutch- eon with(specify')finish, P/N(specify`) "Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. Vico TEFLON is trademark of The DuPont Corporation. Fire Protection Products p@! Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1 .0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.fi47 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems Q� �� 1819 Clarkson Road For additional information,li( �1`� ) Chesterfield, MO 63017 contact your salesperson today at CU� US-�''(�``--� (800)325-4467 (800)325-4467 or(636)537-2600 LISTED J BULL MOOSE TUBE COMPANY �J FAX: (636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 41tP A LPAK) company e-mail:sales@bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 Ductile Iron Threaded Fittings ......„. ,, .........„ , ........., _ .. ., ........... „,,, , .„,.. s , ,,. ,.....„ ,., ,, ..,,,,,,,..„ -„,, „7...17,,,,. ,fil • if-;r3. .,., . //Ili) , . .. ,,,,,,,.........„..,,,..„,,.... li , a aS, SMIT � -- '' COOPER INTERNATIONAL Ductile Iron Threaded Fittings .... Specification s • • CI branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP C CID) US • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 4> • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 - ----- --- - - --- Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 32C 650 300 - 1 ucti a ron fittings - ass I I I / Y QI rrP j c ® us 41441> APPROVED Fig. 35E 3- 90°Elbow LISTED A Size A Packing Weight �► in Part Number in Inner Master lb 1/2 35E 3004 1.13 100 200 0.2 ii, I i 3/4 35E 3006 1.31 70 140 0.3 A 1 35E 3010 1,50 40 80 0,5 1.1 _ 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1 94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow B Size A B PackingWeight in Part Number in in Inner Master lb 3/4 x 1/2_ 350E3006004 1.20 1.22 80 160 0.3 I� - 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 )_____ vA 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0 8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 U 2 x 1-1/2 35RE3020014 2.02 2-16 10 20 1.5 V 2-1/2x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 C 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 T I Fig. 35F 3- 45°Elbow E Size Part Number A Packing Weight \A in in Inner Master lb 2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 4-� 1 35F 301 C) 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1111111l IA 1 2/2 35F 3014 1 44 20 40 1.0 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1 95 4 8 2.7 Fig. 35T 3- Tee Size Part Number A Packing Weight in in Inner Master lb 3.O _ _A 1/2 351 3004 1.13 80 160 0-3 �� �) 3/4 351 3006 1.31 30 60 0.5 1 351 3010 1.50 25 50 0 7 ...... 1-1/4 35T 3012 1.75 10 20 1.1 1< A > 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL* • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 1 ucti e ron 'tongs - ass I I I QUALITY i'L1L '; CCOUS 44011°' APPROVED Fig. 35RT3-Reducing Tee LISTED Size part Number A B C Packing Weight 71111, inin in in Inner Master ib � i C 3/4 x 1/2 35RT3006004 20 1.20 1 22 60 120 0.4 i I_ 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 (= i 1 x 1/2 x 1 35R13010004010 1.50 1.36 1.50 30 60 0.6 I 1 x.3/4 358T3010006 1.38 1.38 1.45 25 50 0.6 t B >( A } 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1 45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1 58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1!4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4x 1 x 1-1/4 35RT3012010012 1.75 1.69 1,75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1 81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1 1 1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1,2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1 25 1.69 20 4C 0 8 1 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1 65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1 60 1.60 1.97 10 20 1.6 - 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2> 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1 41 1 88 10 20 1 3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee , Size Part Number A B C Packing Weight JI���L Ic in in in in Inner Master lb 3/4 x 1 35B13006010 1 45 1.45 1.37 30 60 0.6 II 1 1 x 1 1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 �� 1 x 1-1/2 35B13010014 1.80 80 1.65 15 30 1.0 A 1c B 1-114 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3C12014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2 16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL,® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 112 ..:::L; ' ; ` Ductile Iron Fittings -Class 300 UL/FM C ® US 4Ct; APPROVED A LISTED Fig. 35CP3 -Straight Coupling with Ribs Size Part Number A Packing Weight IIII Iin in Inner Master lb FV-11 - 1/2 35043004 1.38 200 400 0.1 0.2 3/4 35CP3006 1.63 100 200 1 35CP3010 75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 J Fig. 35RC3 -Hex Reducing Coupling 111 Size Part Number A Packing Weight &NM - � in in lb A 1 x 1/2 1 x 3/4 35RC3010004 1.69 80 0.3 35RC3010006 1.69 60 120 0.4 ; 1-1/4 x 3/4 35RC3012006 2.06 40 Inner 160 Master 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight in in Inner Master lb B 1 x 1/2 35HB3010004 1-06 180 360 0.2 ii III ^A 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 i I i , 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2x 1-1/4 35HB3014012 1.25 75 150 0.3 D 2 x 1 35HB3020010 1.38 40 80 0.6 U 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 I t Fig. 35SP3 -Square Head Plug L Size Part Number A Packing Weight in in Inner Master lb "' 1/2 35SP3004 0.94 600 1200 0 07 A 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0-1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1-44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat • A Size A Packing Weight !i in Part Number in Inner Master lb s__ip+eas 1 35U 3010 2.19 20 40 1 0 �� 1-1(4 35U 3012 2.50 15 30 1.2 1���� 2 35U 3014 2.62 10 20 1.7 ���+ 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.srnithcooper.com Ductile Iron Fittings - Class 300 UL/FM Qu.ut i Ar; , c ® uS 4:P' APPROVED Fig. 35X 3- Cross LISTED r A )1( A ) Size A Packing Weight 1d, Part Number in in Inner Master lb I A 1 35X 3010 1.50 20 40 0.9 g 1-1/4 1-1/2 35X 3012 35X 3014 1.75 1 94 12 8 24 16 1.4 III I 8 A 2 35X 3020 2.25 6 12 2.8 Oil Fig. 35RX3-Reducing Cross FB B F---+ Size A B Packing Weight .- Part Number `•,��, A in in in 1.58 Inner Master lb 1-1/4 x 1 35RX3012010 1.67 15 30 1.2 -- I 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 i I A 2 x 1 35RX3020010 2.02 1 73 8 16 2.0 Fig. 35C 3- Cap al ... Size Part Number A Packing Weight in in Inner Master lb A 1/2 350 3004 0.87 300 600 0 1 3/4 350 3006 0.97 200 400 0.1 1 350 3010 1.16 1 10 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 E Fig. 35BC3-Beam Clamp "1.11111111 Size Part Number A Packing Weight AI in in Inner Master lb III in 35BC3003 0.75 00 200 03 ®, ■ 1/2 35BC3004 0.75 80 160 0.5 maim al SMITH-COOPER INTERNATIONAL° • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.corn 114 IPS CARBON STEEL PIPE HOLE CUT PRODUCTS 1 0,52 FireLock® Outlet-T c �� us ® (VdS) LISTED LPCBi cT� SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating lh,3/4,and 1'/15, 20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 13/4 through 76.1 mm/32 to 76.1mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is,suitable for use on standard, lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E" EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade "E"Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel (North America, Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By _ Spec Sect Para Location Date Approved Date 1 IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 FireLock® 0utIet T - STYLE 922 DIMENSIONS Nominal Size Hole Approx. inches/mm Diameter Dimensions-inches/millimeters Weight Each h +0,06/+1.5 Y Z d -0.00/-0,0 T` V W 8 Z lbs/kg - 1'/a X 1 13/16 1.30 1.83 1.10 3.87 2.56 1.0 V ^� i 32 _�15 3D.2 33.0 46.5 27.9 98.3 65.0 0.45 7 3/a _ 3/16 1.28 1.83 1.10 3.87 2.561.1 Ale, �: 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 �. w 1 1 13/16 1.52 2.18 1.10 3.87 2.56 1.2 �� FV I 25 1 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1 Y X Y i 13/16 1.42 1.95 1.22 4.08 2.56 1.2 40 15 1 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3i 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 ; 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 Yz 13/16 1.66 2.19 1.46 4.60 2.56 1.3 50 X 15 30.2 • 42.2 55.6 37.1 116.8 65.0 0.59 3/4 , 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1_-- 13/16 1.88 2,54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2/ Yz 1 3/16 1.91 2.44 1.71 5.40 2.56 1.6 65 x 15 • 30.2 48.5 62.0 43.4 137.2 65.0 0.73 -i 3/4 13/16 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 ' 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X / 1 3/16 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3 13/16 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 13/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). = - - IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 O.52 FireLcck® Outlet-I STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Run Size x Outlet Size 213,Section 16)(C=120)-',FT fnchestmm Feet/meters 1 Y4 X 1 8.5 32 25 2.6 1 V2 X 8.5 40 25 2.6 2 X 1 8.5 50 25 2.6 21/2 1 8.5 65 X 25 2.6 76.1 mm X 1 8.5 25 2.6 *Hazen-Williams coefficient of friction is 120 IPS CARBON STEEL PIPE HOLE CUT PRODUCTS mFireLock ';=a„ -- ..,. - STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B3170NF) ®TOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) cCl us Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications s Function: For fire sprinkler and other general piping purposes. Knurled -- swivel nut design permits hanger adjustment after installation. Features: • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe ,, ' types and protect CPVC plastic pipe from abrasion. Captured design �`=! keeps adjusting nut from separating with hanger. Hanger is easily B installed around pipe. For hanger with non-captured nut order Fig.200S. • (21/2" (65mm)thru 8" (2oomm)) Spring tension on nut holds it securely in hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) Fig,200-1/2.200-3/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and t Factory Mutual Engineering Approved (FM) (3/4" (20mm)thru 8" (2o0mm)). Fig.200-1 to 200-2 Fig.200-21/2 to 200-8 Conforms to Federal Specifications WW-H-171 E &A-A-1 192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F (343°C) " Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size N Designed to meet or exceed requirements of m^ FMDS2-0. c( Fig.200 Fig.200C Fig.200E Pipe Size Rod Size A B Approx.Wt./100 Part No. in. Imm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) 3/8'-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 15.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 55/8' (142.9) 41/8" (104.7) 27 (12.3) - 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.31 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2%13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 Threaded Accessories B32O5 - Threaded Rod (right-hand threads - both ends) (TOLL° Fig. 103) >\ B32O5L - Threaded Rod (right& left hand threads) TL 11�� Specify Length K Size Range: 3/8"-16 thru 3"-4 rod 1: Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. rL Rod is threaded on both ends with right hand threads of the length shown.Also available with left and right hand threads ,�llll specify Fig. B3205L when ordering. 1 Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Desigr Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2%13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8x'1' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/a x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) B3205-11/8 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'1' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'1' 11/2%6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'1' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2%41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'1' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'1' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length �������" ,\lllls�111111��"'* \0,,„4��00%'%' 1111111111� Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m) lengths or cut to length 111r,,,,1111�1 � q Material: Steel " m.i Maximum Temperature: 750°F(399°C) y Finish: Plain.Contact B-Line for alternative finishes and materials. a Order By: Part number, rod diameter and finish ~a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/a"x 120 99-3/8"x length 16 730 (3,24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 5/a"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR T/e"x 120 99-7/e"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. by Pipe Hangers&Supports 236 Revised 4/28/2014 Line vEAN VERTICAL MOUNT SAMMYS" `` SAMMYS for Concrete Installs VERTICALLY into the bottom of concrete structures easily and quickly! Product Features r T _ \. - T - 1 n •Easy two step process(Drill hole& ,, drive Sammy concrete anchor). ,4 •Y."pre-drilled pilot hole required. I •Concrete Installation Tool available for I , a one tool installation process. 1 J a s s "' Metal Deck I .co) : #14 Black 1/4" 8058957 CST 200 5/16 x 1-314" 2400 25 125 Nut Driver O 3/8" 8059957 CST 20 5/16 x 1-3/4" 2400 1475 25 125 Part# 3/8" 8145925 CST 20-SS 5/16 x 1-3/4" 2400 25 125 8113910 ` 1/2" 8060925 CST 2 5/16 x 1-3/4" 2400 25 125 2-i •Tested in 3000 PSI concrete #14SW Red „ sm,-^tAt tot r DRivER PSI I"141 The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes Nut Driver ,f ` into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for Part# installations. 8114910 Wood Concrete / Wood Installation Kit The only tool needed to install SAMMYS& SIDEWINDERS fi 8122910 Concrete Installation Kit(a) i" - Kit includes the following items: / ,- 8113910 #14 Black Nut Driver(b) 1 ONE tool to 8114910 #14 SW Red Nut Driver(c) 1 �. = 8116910 #250 Bit(1/4")(d) 1 the hole and " .. , ' ` " 8117910 SDS Bit(1/4")(e) 1 DRILL 8118910 7/32 Wood Bit(f) 1 8120910 HEX 250 Bit Receiver(1/4")(g) 1 DRIVE the anchor! 8098910 SL 250 Sleeve(h) 1 (a) 8121910 SDS B250 Bit Receiver(1/4")* 1 "Only sold separately-not included in kit Rotary Hammer Drill into concrete Hammer Drill into concrete (h) (h) (g) (d) (h) (e) -41111' �• ,"'..` ► F ,. -.. (ham\ IC) (c) For the most up to date information,visit www.sammysuperscrew.com 10 et 1111 `IF:79:7 lalt ✓' SAMMY X-PRESS® SAMMYS Sammy X Press° (r7cfpt!c ntr' f Ar ta, I"—S. Pfit'(i?? or '''di/11�tC'"PF C.i Product Features ' 'i •The Sammy X-Press expands to provide •Installs in seconds,saving time& (XP) v direct vertical attachment in: installation costs. ` Patent No y ;` -Metal Deck(22-16 gauge) 6,935,821 -Z-Purlin(18-16 gauge) •Use in applications where access to the back of the installed fastener is #!Ifr` •The Sammy X-Press Swivel allows you prohibited.ie.metal roof deck,tubular to hang plumb in extreme roof pitches: steel,or vapor barrier fabric. (SWXP) -89°in Z-Purlin -45°in metal deck for 12/12 pitch •Less jobsite material needed. Patent Pending for •The Sammy X-Press Sidewinder expands •No retaining nut required. to provide horizontal attachment in: (SXP) J extreme -16 ga-3/16"steel-purlin,tubular •Provides design flexibility. or steel. Patent Pending -, variant- roof pttche5 Approvals Rod Part Model Description Ultimate ULTest FM Test Min Max Box Case Application Size Number Pullout fibs) Load(ibs) Load(Ibs) Thick Thick Qty Qty VEr 1/4" 8181922 XP 200 X-Press 200 1146(22 ga) 50(Luminaire) 05(Luminaire) O56" .125" 25 125 Metal Deck 250 850(2'/"Pipe) 940(2"Pipe) .027" 1,,.0 3/8" 8150922 XP 20 X Press 20 1146(22 ga) 185(Luminaire) 1475(4"Pipe) 027" .125" 25 125 Metal Deck 250(Luminaire) .056" 283(Conduit&Cable) 1500(4"Pipe) 060' Qt.°° 3/8" 8153922 XP 35 X-Press 35 1783(16 ga) 85(Luminaire) 940 (2"Pipe) 105" 125" 25 125 Pullin 250(Luminaire) 1475 (4"Pipe) .027" 416(Conduit&Cable) .056" 750(2"Pipe) 1061(22 ga Vertical) 170 vertical(Luminaire) . L"> 3/8" 8294922 SXP 20 Swivel X-Press 20 (45°Off Vertical) 80 @ 45°(Luminaire) 635(2'Pipe) 02T' .125" 25 125 Metal Deck 829283 vertical(Conduit&Cable) 233 @ 45°(Conduit&Cable) 1500(4"Pipe) 1675(16 ga Vertical) 250 vertical(Luminaire) 3/8" 8295922 SXP 35 Swivel X-Press 35 1558(89°Off Vertical) 80 @ 90°(Luminaire) 635 (2"Pipe) .060" .125" 25 125 Purlin 500 vertical(Conduit&Cable) 333 @ 89°(Conduit&Cable) Pre-Pour Structural Concrete@ 3000 psi Metal Deck — Q"" 318" 8150922 XP 20 Sammy X-Press 20 1146(22 ga) 850(2'/Pipe) 25 125 (Pre-Pour) Metal Post-Pour Range II LWCs 35 PCF(Ibs/ft°) Postuk Post-PPoour — HORIZONTAL MOUNT 1250(3%"Pipe) 9 3/8" 8293957 SWXP 35 Sidewinder X-Press 35 1798(16 ga) 80 (Luminaire) 060 125 25 125 Purlin 416 (Conduit&Cable) Pre-Pour Structural Concrete @ 3000 psi Post-Pour Range II LWC<_35 PCF(Ibsl W) Sammy X Press It° INSTALLATION TOOL ,� „, "r` ,y,. , , UXPIT g °v. s . 1 Patent Pending - N•+q '';','• t 1..-V-'. li '' 1'' 7, Part Number Model Description Each City .,, 8194910 ., - UXPIT*' . -Universal X-Press It Tool I # _ - ' 8195910 RXPIT Retro Socket for 8151910 1 ` r 8152910 XPDB 25/64"Drill Bit 1 To watch a video demonstration of the Sammy X-Press,visit http://www.sammysuperscrew.com/sammyxpress.htm 'Tool Includes:Sleeve.Bit Receiver,Hex Wrench,and 25/64"Dnll Bit, For the most up to date information,visit www.sammysuperscrew.com 8 01111 V ra VERTICAL MOUNT SAMMYS® SAMMYS° for Steel Installs VER i''CALLY into the bottom of steel structures easily and quickly! Product Features �� r�� n aril wig •Made with Teks®self-drilling fasteners- €� prew require no pre-drilling required. req ec1 1 flirlii •Install into steel range from 22 gauge_el 112"thicknesses. •Saves time from traditional methods. r,i -. _ •Reduces installation cost. �f'-tt=� •Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. L Approvals Rod Part Model Screw Ultimate ULTest Load Min Max Box Case Size Number Descriptions Pullout(lbs) Load(lbs) lbs Thick Thick Qty City 2 = 1/4" 8024957 DSTR 100* 1/4-20 x 1"TEKS 3 1510(20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8025957 DST 100 1/4-14 x 1"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8026957 DST 150 1/4-14 x 1-1/2"TEKS 3 970(16 ga.) .036"-20 ga 3/16" 25 125 1/4" 8027957 DST 200 1/4-14 x 2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8030957 TEK 500 12-24 x 1-1/2"TEKS 5 3125 (3/16") .187"-3/16" 1/2" 25 125 l/,O 3/8" 8038957 DSTR 1* 1/4-20 x 1"TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 - fit, 3/8" 8037957 DSTR 1-1/2* 12-24 x 1-1/2"TEKS 5 1510(3/16") 1500 1475 .060"-16 ga. 1/2" 25 125 c,O 3/8" 8039957 DSTR 516* 5/16-18 x 1-1/4"TEKS 3 2200 (20 ga.) 1500 1475 .036"-20 ga 1/8" 25 125 3/8" 8040957 DST 10 1/4-14 x 1"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 #14 Black 970 (16 ga.) Nut Driver 446 (20 ga.) Part#8113910 3/8" 8077925 DST 10-SS 1/4-14 x 1"TEKS 3 970 (16 ga.) .036"-20 ga 3/16" 25 125 3/8" 8041957 DST 15 1/4-14 x 1-1/2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8078925 DST 15-SS 1/4-14 x 1-1/2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8042957 DST 20 1/4-14 x 2 TEKS"3 ' (20 ga.) .036"-20 ga 3/16" 25 125 970(16 ga.) 3/8" 8043957 DST 25 1/4-14 x 2-1/2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 446 3/8" 8044957 DST 30 1/4-14 x 3"TEKS 3 (20 ga.) .036"-20ga 3/16" 25 125 970(16 ga.) Q 3/8" 8045957 DST 516 5/16-18 x 1-1/4"TEKS 3 1500 (3/16") 1500 1475 .125"-1/8" 1/8" 25 125 t*it.,Q 3/8" 8046957 TEK 50 12-24 x 1-1/2"TEKS 5 3125 (3/16") 1500 1475 .187"-3/16" 1/2" 25 125 _ 1/2" 8031925 DST 2.0 1/4-14 x 2"TEKS 3 446 (20 ga.) .188"-3/16" 1/4" 25 125 970 (16 ga.) 1/2" 8033925 DSTR 1.0" 1/4-20 x 1"TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1/2" 8034925 DSTR 5.16* 5/16-18 x 1-1/4"TEKS 3 2220 (20 ga.) .036"-20 ga 1/8" 25 125 - ill 1/2" 8035925 DST 5.16 5/16-18 x 1-1/4"TEKS 3 1500 (3/16") .125"-1/8" 1/8" 25 125 1/2" 8036925 TEK 5.0 12-24 x 1-1/2"TEKS 5 3125 (3/16") .187"-3/16" 1/2" 25 125 —#14 SW Red Nut Driver "Includes retaining nut u , Part#8114910 SAMMY Swivel Head- for Steel ',> "` TiCRLLY and swivels uh to 97°in steel strt ^` �� Or ' Product Features •Eliminates distortion of threaded rod in •Installs into angled Z-Purlin;Allows sloped roof applications. threaded rod to hang plumb. •Accommodates 3-1/2 x 12 pitch. •Allows 17°deflection from vertical. Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case Size Number Descriptions Pullout(Ibs) Load(lbs) Load(lbs) Thick Thick City City '' 30 8137957 SR-DSTR 1* 1/4-20x 1" 3220(3/161 1500 1475 035" 3/16' 25 125 a- 11111 )';-# "Includes retaining nut (Does not comply with ROHSrequirements) #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.sammysuperscrew.com 6