Loading...
Plans (2) 11,S7 0a21- 003e4-/ 1 s V 3- j fry 0/1/LIAJ/P/ 1-04 r p "POLYGON AT ROSHAK RIDGE" LOT 182 HUB AND TACK CERTIFICATION NE 1/4 SEC. 7, T 2 S, R 1 W, W.M. CITY OF TIGARD, WASHINGTON COUNTY, OREGON SURVEYED APRIL 13, 2022 _ PREPARED FOR: — — — TAYLOR MORRISON, INC. 703 BROADWAY ST., SUITE 710 VANCOUVER, WA. 98660 c.) SW DARWIN LOOP 6 N N8954.00"W 50.00' 't f t - - - - - - - -.=.- - - — - --- N 6.00 PUBLIC \ i UTILITY EASEMENT t5 0C-6,-- ,.. c < in `, It) co FT?. a ci o CD CO LOT w LOT LIJ LOT t 183 o 182 b 181 P o , 'f:i co io P P o o co o o ,__ z z .) 8.00' PUBLIC UTILITY EASEMENT e r., O '6' 0 5 Icc: '04 -4. u IN F. z REGISTERED - — — — — — — — — — — — — — — — — — — — — — O PROFESSIONAL u LAND SURVEYOR d N8920'476E 50.00' m ' •--- ',.....,-<' ,,----- ,-' a. OREGON JULY 9, 2002 a. TRAVIS C. JANSEN SW BULL MOUNTAIN ROAD ?5 57751 ..." (COUNTY ROAD NO. 262) .0 , RENEWS: 6/30/2023 0 c I, TRAVIS C. JANSEN, A REGISTERED PROFESSIONAL LAND SCALE g SURVEYOR IN THE STATE OF OREGON, HEREBY CERTIFY THAT I 20 0 10 20 25 HAVE ACCURATELY SURVEYED AND STAKED THE OFFSETS TO ira 51 THE FOUNDATION ENVELOPE FOR LOT 182 OF THE PLAT OF 1 INCH = 20 FEET I 02 "POLYGON AT ROSHAK RIDGE". z.— .F3r DRAWN BY: AY DATE:04/13/22 ----N\ 5 PACIFIC COMMUNITY DESIGN 1 ,I REVIEWED BY: T2 DATE:04/13/22 z PLANNING - ENGINEERING - SURVEYING , ‘ PROJECT NO.: 395-010 (503) 941-9484 ____., CEDESIGN FIELD REPORT Page 1 of 1 GDI Project: Polygon-113 05 Prepared By: Heather Herinckx Project Name: Roshak Ridge 6/2/22 Location: SW Bull Mountain Road and SW Roy Report#: 226 Rogers Road, Tigard Arrival: 1315 Departure: j 1345 Weather: Rainy, 50's Permit#: TBA Site Visit Requested By: Sam (Taylor Morrison) Met With (on site): Sam Purpose: Observe subgrade for lot 179, 182, 183, 184 Outstanding Issues: Upon arrival, I was informed that subgrade had been prepared for the lots mentioned above and indicated on the attached site plan. I observed subgrade conditions to generally consist of brown silt. Crew placed approx. 2- to 4-inches of crushed over subgrade. Using a %2-inch diameter steel foundation probe, I evaluated the relative consistency of subgrade conditions, probe indicated medium stiff to stiff. Based on our observations and probing, it is our opinion that the subgrade observed today, as indicated on the attached site plan, has been prepared in general accordance with geotechnical recommendations. Distribution: Attachments: Site Plan (1) Reviewed by: This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services. We rely on the contractor to comply with the plans and specifications throughout the duration of the project irrespective of the presence of our representative. Our work does not include supervision or direction of the contractor,the contractor's employees or agents. Our firm is not responsible for site safety. This field report is a DRAFT representation of our field observations,to 'ng,and preliminary recommendations.The report can only be considered final upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By"section. Signature: 9450 SW Commerce Circle,Suite 300 I Wilsonville,OR 97070 1503.968.8787 I www.geodesigninc.com Polygon-113-05 6/2122-HHH NOT TO SCALE GENERAL NOTES t .k ,, kaien l n , e•Lnc+cerill MATCHLINE KM..xw COMPANY SITE•P=..HE, ET:.1 _•• •1 P,dt T / '`4 ' ' .� - l..lr,ty , MU CaSCRIPTIOM 1 F II F J. „ t ;;;;;;_': .. 't. 1 - N vu « " 4 I Yt M », S. 1 Polygon at { / �' ,„ Roshak Ridge — a I ,I'r ;r C trucnoN ,meats . ip 1 , 1 , i , 'q i i 1 1 1 �� , mRu _ //G r t, a _'lB\.S SITE Atir _ 1 I a \ 44- __ _ $�.'�iS/�}J PLAN 2.. iila} , I 16 t, '. '.' . ”. M M n. n ". "' M „/, IN / ,., 1 e� _— 6 dill 1t L--�' �� r.." .{ 4.2 ELEVA11ONroktL :NGVD 2%/ 9 �ie!--C� ^ `