Loading...
Specifications Gue CITY OF TIGARIX REVIEWED FOR CODE COMPI,?ANCZ Approved: ] OTC: permit A S��. -4-7 ,, %Cp,Address. 2T►d � Suite fit+: . H22?ppZ • Datta 8UK1)/ 1G Structural Calculations 4,ryy PREPARED FOR: American Structures & Design 218 Stewart Road SE i 5 Pacific, WA 98047 S a PROJECT., Hampton Ridge Apartments S` Aluminum Railings 15 2220431.20 4 PREPARED BY., Jerad Harmon, PE Project Engineer REVIEWED BY 4 Andrea Sauter, PE, SE Project Manager Dan Booth, PE, SE Principal VALID17Y OF THE ISSUANCE OF ERMIrT BASED ON CONSTRUCTION DATE: DOCUMENTS AND OTHER DATA SHALL NOT PREVENT May 2022 THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. OSSC 105.4 Civil Engineers • Structural Engineers • Landscape Architects • Community Planners 9 Land Surveyors 9 Neighbors Structural Calculations For Hampton Ridge Apartments Aluminum Railings Tigard, OR Project# 2220431.20 Project Principal Dan Booth, PE, SE Project Manager Andrea Sauter, PE, SE Project Engineer Jerad Harmon, PE Design Criteria Design Codes and Standards Codes and Standards: Structural design and construction shall be in accordance with the applicable sections of the following codes and standards as adopted and amended by the local building authority: Oregon Structural Specialty Code, 2019 Edition. Structural Design Criteria: Live Load Criteria: PSD Guardrails 200-Ib concentrated �5��' I N US or 50-plf ` y Intermediate railing 50-lbs over 1ft2 88401PE Project Description NQV The project consists of the design of aluminum railings to be attached to an existing wood frame structure located in Tigard, OR. Verification of the existing structure for the applied loads from EXPIRATION DATE: 12/31/2023 the railings is by others. OS/2y/2022 Loading Diagram Project: Hampton Ridge Apartment Railings Project Number:2220431.20 Date:05/17/22 By:JCH Aluminum Design Manual 2015 Edition&2019 OSSC (Blum 13 Structural Load Diagrams Note: Loads shown are unfactored and in accordance with ASCE 7-16. Reactions V = 217 lbs M = 9719 in-lbs `v M 0 �e U Fascia Mounted Railing Structural Calculations Project: Hampton Ridge Apartment Railings Project Number:2220431.20 Date:05/17/22 By:JCH Aluminum Design Manual 2015 Edition&2019 OSSC Custom Railing Extrusions 2.376 -- 2.376 2.376 EEIE - INTERNAL POST 2 376 BRACING FOR END POSTS WITH CABLE WILL PE—POST EXTRUSION PROFILE PE—POST EXTRUSION SCALE=1:3 W/INTERNAL POST BRACE SCALE=1:3 r Typical Railing Post Reinforced Railing Post for Cable Railing TR-200 PROFILE SCARE-t 3 3.50 75 t 2S O.STB -T--•----- 2.125 1.018 2.50 QR-100- BOTTOM B — FI RAIL W/RC81 SCALE=1:3 FI—FLAT INEILL FOR SERIES TR200 & TR999 (WHEN USI G. CABLE) Bottom Rail IF r 0,6251 INFIL) FOR SERIES TR200. TR929_& 400 (WHEN � USING GLASS OR PICKET) SCALE=1:3 Top Rail Picket V Project: Hampton Ridge Apartment Railings Project Number:2220431.20 Date:05/17/22 By:JCH Aluminum Design Manual 2015 Edition&2019 OSSC Railing Post-Balcony Mounted and Deck Mounted Section Properties Material Properties A(in) 1.010 (6063-T6) Post Spacing 52.125 in I.&4) 0.852 Fty(ksi) 25 Concentrated Load 0.217 k Sc(in3) 0.717 Ft„(ksi) 30 St(in3) 0.717 Fey(ksi) 25 LTB A 19.18 r,,,(in) 0.918 E(ksi) 10,100 ryy(in) 0.919 Cc 78.4 3 (r— L,S Z (in 0.8529 ��CA— b(in) 2.376 t(in) 0.1 Flexural Limit State Reference a M„P/0(kip-in) Max Length(in) Rupture F.2 1.95 13.12 60 Yielding F.2 1.65 12.92 60 Local Buckling" F3.3 1.65 10.73 49 Lateral-Torsional Buckling F.4 1.65 12.61 58 "Allowable Stress from Limiting Element Method(Below) Limiting Element Method(Table 2-21): Elements A=b/t F/n for A<A1 Al F/Q for A1<A<A2 A2 FRI for W2 Elements-Uniform Flanges Compression-Flat g elements supported on 23'8 - 22.8 14.96 39 - both edges Elements-Flexural Sides Compression-Flat elements supported on 23.8 22.70 34.7 - 93 - both edges Maximum Allowable Span 4.12 it DESIGN OK Maximum Actual Span 3.73 ft Project: Hampton Ridge Apartment Railings Project Number:2220431.20 Date:05/17/22 Aluminum m Design Manual 2015 Edition&2019 OSSC Picket Infill Design 5/8"x 5/8"x 0.05"picket railing for intermediate guard load of 50lbs over one square foot Section Properties Material Properties A(int) 0.115 (6063-T6) Picket Spacing 4.5 in I.(in4) 0.006 Fty(ksi) 25 Concentrated Load 0.019 k Sc(in3) 0.020 Ft„(ksi) 30 (at center of picket span) St(in3) 0.020 Fc,,(ksi) 25 Z(in3) 0.0248 E(ksi) 10,100 b(in) 0.625 Cc 78.4 t(in) 0.05 Flexural Limit State Reference 0 M„P/0(kip-in) Max Length(in) Rupture F.2 1.95 0.38 81 Yielding F.2 1.65 0.38 80 Local Budding* F3.3 1.65 0.30 65 *Allowable Stress from Limiting Element Method(Below) Limiting Element Method(Table 2-21): Elements A=b/t F/n for A<X1 Al F/0 for Itl<W2 A2 F/fl for 11>A,2 Elements-Uniform Flanges Compression-Flat 12.5 15.20 22.8 _ 39 _ elements supported on both edges Elements-Flexural Sides Compression-Flat 12.5 22.70 34.7 - 93 - elements supported on both edges Maximum Allowable Span 5.40 ft DESIGN OK Maximum Actual Span 3.13 ft Project: Hampton Ridge Apartment Railings Project Number:2220431.20 Date:05/17/22 By:JCH Aluminum Design Manual 2015 Edition&2019 OSSC TR-200 Top Rail with Flat Infill Plate(Glass/Picket Infill Plate Similar) Section Properties Material Properties A(int) 1.011 (6063-T6) Post Spacing 52.125 in 1.(in4) 0.469 Fty(ksi) 25 Concentrated Load 0.217 k SJin3) 0.486 Ft„(ksi) 30 LTB A 54.0 St(in) 0.554 Fey(ksi) 25 L rx(in) 0.681 E(ksi) 10,100 = b ryy(in) 1.244 C, 78.4 1.2rycb Z(in3) 0.6249 Flexural Limit State Reference O Mnp/i2(kip-in) Max Span**(in) Rupture F.2 1.95 9.6 177 Yielding F.2 1.65 9.5 174 Local Buckling* F3.3 1.65 6.0 111 Lateral-Torsional Buckling F.4 1.65 8.4 154 *Allowable Stress from Limiting Element Method(Below) Limiting Element Method(Table 2-21): Elements-Flextural Compression A=b/t F/fl for A<A1 Al F/0 for A1<A<A2 A2 F/n for W2 Elements-Uniform Flange Compression-Flat elements 38.9 - 22.8 12.39 39 - supported on both edges Elements-Flexural Webs Compression-Flat elements 20.1 22.70 34.7 - 93 - supported on both edges Maximum Allowable Span 9.24 ft DESIGN OK Maximum Actual Span 4.34 ft Project: Hampton Ridge Apartment Railings Project Number:2220431.20 Date:05/17/22 By:JCH Aluminum Design Manual 2015 Edition&2019 OSSC Q BR-100 Bottom Rail Section Properties Material Properties A(in) 0.394 (6063-T6) Post Spacing 52.125 in 1.(in4) 0.143 F,y(ksi) 25 Concentrated Load 0.050 k S,(in3) 0.135 Ft,(ksi) 30 St(in3) 0.135 Fey(ksi) 25 LTB A 15.5 r),(in) 0.602 E(ksi) 10,100 ryy(in) 0.358 Cr78.4 Lb Z(in3) 0.1897 1.2ry cb Flexural Limit State Reference O Mnp/0(kip-in) Max Span(in) Rupture F.2 1.95 2.9 233 Yielding F.2 1.65 2.9 230 Local Buckling" F3.3 1.65 1.4 115 Lateral-Torsional Buckling F.4 1.65 2.7 219 'Allowable Stress from Limiting Element Method(Below) _Limiting Element Method(Table 2-21): Elements-Flextural Compression A=b/t F/A for A<Ai Al F/O for Al<A<A2 A2 F/n for A>A2 Elements-Uniform Flange Compression-Flat - g elements supported on one 14.5 7.3 - 13 10.66 edge Elements-Flexural Web Compression-Flat 8.3 22.70 34.7 - 23 elements supported on both edges Maximum Allowable Span 9.56 ft DESIGN OK Maximum Actual Span 4.34 ft Project: Hampton Ridge Apartment Railings Project Number:2220431.20 Date:05/17/22 By:JCH Aluminum Design Manual 2015 Edition&2019 OSSC O Railing Connections TR-200 Rail to Post (4) S-S. #10x-3/4" TEK Determine Capacity of Screws (4)#10 SCREWS TO POST 0.07"ALUM THICKNESS,MIN TR-200 0 3 t Ft„ 525# SHEAR= MIN Ide 2 D t Ftu 798 # 2%"X2%" POST —' R„/0 175 #/screw (4)Screws = 700 # OK RCB1 Bracket to Post Determine Capacity of Screws (2)#10 Screws from bracket to post (2)#10 Screws from BR-100 to RCB1 (one ea side) 0.07"ALUM THICKNESS,MIN 0 3 SHEAR= MIN Ide t Ft„ 525 # 2 D t Ftu 798 # R„/f2 175#/screw (2)Screws = 350 # OK RCB1 BRACKET W/SS#10X t}$" TEK 4" BR-100 SCREW O.0 S.S. P0A4°' TEK DECK SURFACE Project: Hampton Ridge Apartment Railings Project Number:2220431.20 Date:05/17/22 By:JCH Aluminum Design Manual 2015 Edition&2019 OSSC Post to Knife Plate Connection Determine Capacity of Bolt Group (2)3/8"4)Bolts 1/8"thick alum tube& 1/4"alum T-Channel Bracket RA-PKP (ALUMINUM Bolt Shear:AISC 360-10,J3 KNIFE PLATE) n� Rn = Fn Ab Fn 33.8 ksi (2) 0.375'x3.50" THRU BOLT WJ Ab 0.2 in2 (2) 3/8-16NUT-18-8 W/2 3/8 LOCK WASHER RA-PE O 2 & (4) FS-�6-FLATW-18-8 RWO 3.31 kips/bolt Bearing at Alum: Fn, 30 ksi Q 1.95 Rn= MIN Ids t Fp, 5.63 kips/bolt g 2 D t Fi„ 5.63 kips/bolt M Rn/0 2.88 kips/bolt Pall W 5769 Actual P # 2991 OK Project: Hampton Ridge Apartment Railings Project Number:2220431.20 Date:05/17/22 ._, By:JCH Aluminum Design Manual 2015 Edition&2019 OSSC Railing Bottom Bracket Connection Determine Allowable V (4) 1/2"dia Thru Bolts with Simp DTT2Z Holdowns Shear Capacity: P tY: N Z 460 #/bolt V 1840 #total(4 bolts)(Cd= 1.0) Tension Capacity: a Simpson DTT2Z M i Tallow 1825 #/holdown (Cd= 1.0) SIMPSON CDTT2Z V max(#) = 217 V all(#) = 1840 OK ca T max(#) = 1851 No T all(#) = 1825 Marginal-OK 0 N U) U� t'J R FRONT VIEW Reference Drawings HAMPTON RIDGE APARTMENT 13301 SW 72ND AVE, TIGARD OR 97223 ® RAILING ❑ BALCONY ❑ SUNSHADE GENERAL CONTRACTOR:LIFETIME EXTERIORS SHEETFLEVEL-3FLOOR NAME REV DATE PROJECT ADGRE95:1=18W]IIgAW.TIOMDOR li N0. N0. 00 00 04-29-2022 T PUN 00 04-29-2022 2 PUN 0004-29-21122ONO 3RGE 0 04-29-2022 RAIL LENGTH 1892 lF 4 RAIL C&D ENLARGE COLOR:BLACK ABBREVIATIONS TOP RAIL TWE:TRZOD SYMBOL LEGEND 5 IRAIL DETAINS INFILL TYPE:PICKET BA-BF Bakony F— BA-BSF Bakony Sub Fa..io FIELD WELD SYMBOL BA-BO Bokony D.K'N NM WELD- L- OUND SYMBOL M-BOEB Bakorry Decking End Bond BA-BJ Bakor Joi.l a Or OF PREPARATION: BA-BSFB Bakony Sub Fo.cio Socket SIZE OR STRENGTH FOR BA-BSFA Bakony Sub Facia Mgk 1`y CERTAIN WELDS BA-BSR.825 Sol."Sag Rode Ill FF a S NOTE: BA-BSRS So Rod S— TT., T BA-RSPB Sag Rod B.— b F 1)'•'USED FOR ALERTING GC RESPONSIBLE TO VERIFY BA-BSMG Side Mount Socket `9EPECIF.ION 1)IXISTING STRUCTURE TO BE VERIFIED BY ENGINEER OF RECORD BA-P-%X% Bokony Poe PROCESS,OR OTHER 2)ALL DIMENSIONS SUBJECT TO CHARGE MRA-P2.375X%X Rail Post REFERENCE By NEEP TO BE RA-TR10O TR100 R—To Rail BASIC WELD SYMBOL VERIFIED ON SITE BY INSTALLER PREP TO CUTTING RA-TR999 TREES Top Rol P OR DETAIL REFERENCE 3)ALL OPENINGS WILL NOT PASS{'SPHERE RA-1RM0 TR2OD Top Rail ARROW CONNECTION REFERENCE LINE 4)BLOCKING AND WALLS BY OTHERS SHOWN FOR REFERENCE ONLY RA-PT.825X%X Picket Infill TO MROW SIDE MEMBER OF JOINT RA-Fl Flet Infill 200/999(for Cable) LOCATION OF ELEMENTS OF A WEEDING SYMBOL RA-IFXX MINI 200/999(For GW./Pkkst) RA-SPESPE I Serie.100 Pkbt Spacer E.budan TYPICAL NOTE FOR BALCONY RA—SPE D, BR1o0 Soft, Pill Rall / ✓ (/ RA-8P3X5 BP P..t Bo.e Plot. NOTE: M-SP-003.875 SP41 Serie.100 Picket Spoc.r PLUG OR SLOT 1)SUB FASCIA BRACKET(MINIMUM 3 PER UNM SPACING VARIES ON RA-RC81 M91 Roll Conn Cog BMck for Top! FILLET WELDING SYMBOLBEVEL WELDING SYMBOL WELDING SYMBOL LENGTH OF BALCONY. Bottum R.H. ,:,�DETAIL NUMBER DETAIL NUMBER 2)SAG ROD BRACKET AND SUB FASCIA BRACKET MUST BE ATTACHED RA-FMPB-INT 9rxBut'1'Off Set Intermedkte Fascia Mnt F- /Al DETAIL TITLE TO SHEETING,BLOCKING.CONCRETE OR STRUCTURAL SURFACE RA-FMPB-OC FMPEI I'OR Set Out ide Camey Fack it\R'X•J�PAGE NUMBER (NEVER DENSGUSS.GYP OR SHEET ROCK) MM Brrcket -NEW GIRECTIO 3)a C T IF�LOC WALL GAP FOR THRV BOLTS AT SAG ROD RA-FMPB-IC FMPB-8'1'OR Set Inside Comer Facia _ ENLARGE BOX \SCALE BRACKET LOCATIONS MM Bracket DETAIL REFERENCE MARK DETAIL DRAYIING EPEE RA-FMPB-OBE FMPB-8'1'Off Set O.N.Po.t Corar- Ill 14 DETAIL NUMBER DUNE NUMBER RA-PKPoX6%.3]5%%X Port Knite MI cl., )( RA-PV-120 PV-Picket Veryl-Clear TYPICAL NOTE FOR RAILING RA—cv-BOT GV-Bottom Mod Glop A"I PAGE NUMBER RA-GV-TOP GV-Top Rpid Gkew Vinyl DETAIL REFERENCE MARK DETAIL REFERENCE MARK NOTE: GT-CLEAR 1/4' 1/4'Clear T.mp.Glen-S—IHl Edgn FACING SIDE 1)FASCIA BRACKET(RA-FAB)AND FASCIA KNIFE PLATE(RA-PKP) RA-NC Nylon Bolt Cop Cover `f!GEfAIL AMBER MUST BE ATTACHED TO SHEETING,BLOCKING,CONCRETE OR RA-CW W.1wr I /x'� STRUCTURAL SURFACE.(NEVER GYP OR SHEET ROCK) XX NUMBERPAGE SECTION DETAIL ROrMENCE MARK CLIENT NAME DIMWN BY:6" LIFETIME EXTERIORS FAREED IO, DATE: RSUED BY PAGE ^MENICAN JOB NINE DATE 04-29-2022 1 � AA®aCAN9eWIA'aA69 a Dl3K%ilNc HAMPTON RIDGE APARTMENTS CHECKED BY: BRYAN 2 uesYewMrAnse eA.mTc,wAe.wo BID REM: A^PROVED BY: 00 3 FtIOI� LSy1xWUe,Vck xualaAW SONE: 4 Note:®This document has been developed and created by AS&D. Information contained herein cannot be used unless specifically permitted in writing by AS&D i D -------------- i I I I I I I �;- -- --------- ---- ------_-_- -- - i E I I I I I I I I J I II it I I I I I I I _ -------------- ---------- ------------- 4C ------------F �--- I - - I I I I I I I ° e i Qn: 10 auEVE�-x Plaaa Puw �1,�—taa� ■ ACs LIFEDM�EXTERIORS �: FAREED ryp, MIG mum erlj� Du x ,/�Mi■RI/C� aae WAC. 04-29-2022 I AArewcv+arxu�cl�lvs�m� ax. HAMPTON RIDGE APARTMENTS QIEDin W, BRYAN 2 1 nlsnnVART lns3 PAD1fCwA9wa RD REIT: APFFAM er: 3 PF1aNDLbY•....PAx Aivam.atl /��n,.a� LEVEL-2 SGYE 4 Note:m This document has been developed and created by AS&D. Information contained herein cannot be used unless specifically permitted in writing by AS&D i Tr-----------A------------- I I I I i I I I I J 1� I I I I I I II I I 1 I I I I I I I I I I I I I I i I I li I I I I I L_ �I --4�i i f1' ----- I I I I I ----- I I I --�-- —�- on: 10 am RYE: OR"BY. REV S UFEYIME EXTERIORS �� FAR EEA ap, aRE: 611ED B/ NUMBER AS CAN roe wwE o4-zs-2o22 i NAMPTON RIDGE APARTMENTS QiEi7��' BRYAN 2 2 srew.urrasa eam+c wa woo gD RDk X'PRM W. 3 moue u�aiwp s�z a zv aiuw Note: This document has been developed and created by AS&D. Information contained herein cannot be used unless specifically permitted in writing by AS&D s --------------------------------------- u II;. zeo(2l'-e'j I is II 1 ..ZX(D — — — I I I 2z•_yS• 1 I I L--------------------------------------- OTT: 20 r\RNL-A FLaoR PIAN r---------------------------------- Jar 122X[10'-241_.. _. In p11 II __ D W r r I TiP.a%c ttP.2% 6 I s I (])Ea O.0 I I I I 132y� I •� g111r"D�0 PIAN aNRNL d R-+s CUDR NAME DRAWN BY: GUARDRAJL1892LF AS D LIFETIME EXTERIORS FAREED RD, wTE: f��]E3 w1E: ROP IBL sCRxs zoo .UMERICAN aoe nwe 04-29-2022 t CHECKED BY: INF':BLACK ,umuulaslxacrtmmsa ua+wc HAMPTON RIDGE APARTMENTS BRYAN 2 Co'.BLACK r1 mere•MiuTpPA%�M ssttu2 BIG fIDA: APPROVED 9Y: 3 //�mwmmm.mm RAIL SCALE: a Note:CThis document has been developed and created by AS&D. Information contained herein cannot be used unless specifically permitted in writing by AS&D If---------------------------------------------------------------------- I OPENING 11D>f OPEWND 1Id4 j I + I 4h 44 IIII cx=c a_c5v716-c,vI _- - �2�oP�3 NLa-TCr:fL0T0DR 1--c.25 oT.YPc.3�X 7b5s46 low. IDS L----------------------------------------- cr --------------------------- -_5-c716-�-c--�---e-ms--------IIIIIII - --------- I I I I I 1 I I II I 1 II I n U: U I IMI I 1 M I + ui -----------------------7 I II " '. � A I R '. OPENND JB r.. . . i y it L I�N 41TYP331'76—�I TYP.2z . Y 3536___-- "II// n I ! Nw I I I I N 'C I nL-----------------------J 40 1 n QTY: 20 I N l I PL-EFIFIO � I u 6 3 4=:A I I I I I I I i---------------------------J I L__________________________J oTr: To /.RAIL-D FLDOR F'VN °Tr. To v.��F_,'� /l3TRAA.—D FLooR PUN CLIENT NINE: DRAWN BY: f%IARDFWL:1 e871.F s LIFETIME E%TERIORS FAREED ND, DATE: KSUED Br N_ TDP BNL SERES 2DD /�M■RIC/1N ADB NAME: DATE. 04-29-2022 1 BY: BRYAN w INFILL-PK'KET ,AN=---AN=--- HAMPTON RIDGE APARTMENTS CHECKED 2 Y ODIDR:BLACK eHoim Muwwsa PeVt�W 4ss atawat 9IWN D MM APPm BY: 3 /mmwmnve� RAIL SCALE: 4 Note: This document has been developed and created by AS&D. Information contained herein cannot be used unless specifically permitted in writing by AS&D „ NOTE A NATE!”, (Al.6083-Te) NDM INTERNA,: (AL 60e3-Ta) SIDING >% (ALu4�INe M - M +3(. s /-sHEARHINa TA KNIFE'tA AC==L g (� (2)..3)5Ls.3.50'THRU NOW/ n 4 (2)3/8-1514UT-1a-B W/2 3/6 RA-PF Y &(4)FS-34s-MTW-118B 4� • (AL6UMM�O4 KNIFE PUTE) N O II t �e TOP VIEW .2504 M-PE NEXBF-3/8-l"03.50 LT w 1s%o3.so %� i m 5000 (2T RA-PFFD] ,-3/a-18 Nur-la-s IST (4) f5-)/18-MIW-1B-8 CAP 3.)50 (2) NriAN CAP R ((2) 1.000 ).Ooo 3.8)5 4.000 .)50 1.000 '^ AT7 OPP OT NM)AT ORP CORNFRSOF 9UCKET NDTf2Z(BY OTHERS)AT OPPCORNERS(4)..5625 THRU FRONT VIEW SIDE VIEW (4)&5825 THRU SMPSON OTRZBRCKETTOBEATTACHWPLATE A NSTALLED AT DPP (4 r 15x8 18-6 SS TNRU BOLT BT AS&O PLATE LRBY MERU /a-18%0350 �2)OTT22(BY OTHERS)AT OPP CORNERS (2 TOTAL PER M" W/ 2 BRACKET TO BE ATTACH W(2) 2%B 41N Ai BRACKET -18 NUi-18-B ()2���WASHERS AT OPP CORNERS / -)/t e-MTTV-IB-e (4)r Khxa•1a-a 5S THRU BOLT W AS&0 P WASHER (2)OTT2Z(BY OTHERS) 011 CAP (2)2'FENDER WASHERS (4)FS-I/2%Oe.00 18-9 SS THRU BOLT 2 WRN 2'FENDER WASHER %KE OETNL DTT: 460 (ol KNvIFE OETNL OTY: 140 /i�pAIL SECTION \J cT7T RA-TR200 RA-PT (2) FS-10X.]5-PHILPANTEK-55 RA-SP-003.a75 RA-PV RA IF M-BR100 N-w RA-Kcal (2)FS-10%2.0-PANSOTEK-55 RA-SP-003.8)5 (2)M-10X.)5-PNIPNTIEK-A M-PE N-PE CLIENT`AWE: DRAWN BY; S LIFETIME E%TERRORS FAREED NO, BATE: MGE4A �MERICAN JOB NAME,- o4-2s-2022 ) 5 cl&T;Km Br: ANffNGET s1AT,CrTMeir iRa[W D+c. HAMPTON RIDGE APARTMENTS BRYAN 2 wioN&nNi za�iw�PPAlt�a matu.5u 810 IIE4: APPROVED W. 3 RAIL SNE: 4 Note:o This document has been developed and created by AS&D. Information contained herein cannot be used unless specifically permitted in writing by AS&D R ' O The key to protecting both building integrity and builder reputation is to utilize effective moisture control solutions.Toward that end, Fortifiber Building Systems Group°offers m . WeatherSmart Drainable,a scientifically-de- �$ signed weather-resistive barrier that provides t•f.h V OMAN Ofts the optimum combination of water resistance, + 4 • breathability and high-performance drainage. .st.s WearherSmart •: Drainable represents ` ^r DYsi�LGable'sl(7ae?lteCl P . 3• the next genera- tech nolog y channels tion in housewnp liquid aaway f om the technology,offering ��- ;! Weathers well asseyrtbly,.. architects,specifiers and builders '^ :—�K%atliersiiuit` - a smart ` ' •a .,.`: .!�Dr`alnabfe'�.:r Drainable hmaewor } •'` a'k housewrap solution-one °1' _ that delivers the ideal balance enhanced drahWle between breathability and water '`��`�^ patter,dir ectr mater protection,so it can be used in any climate and behind most ex- wit of the waU gnickly. 4'm �;terior claddings.WeatherSmartDrainable takes the protection ogf your .�k i structure to the next level,with patented technology that actually channels liquid away from the wall assembly and to the ground. With aerr,rating •A'`�_:•' p ting of the WeatherSmart Drainable design provides architects and builders with the ideal level permeability ofva or bili P P ry-so it's the smart choice k,vinyl and wood siding.Manufactured from behind fiber cement siding,bric spunbond polypropylene fabric with a non-perforated breathable barrier layer,thRFsiswrct e ExcEEos WATER product is embossed for drainage efficiency.Its design provides a highly reliable STANDARDS air infiltradoa barrier that is incredibly durable and W stable.It resists tears, - abrasions and punctures. • >9S%DRAmm EFROWy : :Y Part of a Complete Moisture Control System CRUSH Ru=ANr DRA*mLE i PATTERN The product is part of a complete Moisture Control System for walls engineered by the Fordfiber Building Systems Group,which has been chosen by builders and RESISTS TFAU,AeRAstoRs architects to protect over eight million homes and commercial buildings from the AND PUNCTURES problems caused by water intrusion.When integrated into the building envelope, • OUrsrmmNa SURFAAm cr our products help manage and eliminate moisture-related problems-including AND UV RESISTANCEwater-related structural failures,mold and mildew. Decades of Proven Performance WeatherSmart Drainable is a product distributed by the Forti- fiber Building Systems Group.With more than a seventy-five 1939 year History ofproven performance,technical expertise and - practical know-how,the company has become a trusted partner ' ^ to builders,architects and code officials. r r' - YYtA f HfiK5J1V1 4K 1 ONAI111A13LE Product Description:WeatherSmart Drainable is a !imitations:Product should be covered within six months.To• scientifically advanced housewrap designed for use within ensure maximum exposure time,store unused product in an area a variety of exterior wall assemblies.It provides excellent not exposed to sunlight Inspect product to insure it is free of protection from wall damage due to water intrusion and any protrusions or damage which may detract from the weather- condensation. resistive barrier ince Holes-teals or b`nt3•. punctures should-be Composition:WeatherSmarc Drainable is a spunboad sealed with Moistopm Sealant avid Liquid Flashing or•Foiv6ber Polypropylene fabric with a non-perforated breathable barrier Sheathing Tape.This.productisnot recommended£orhorizontai, layer.The product is embossed for drainage efficiency. roofing or below grade applicatibns..Ensure that a layer of Size&iftight:WeatherSmarc Drainable is available in Super jumbo Tex®60 minute is used to separate Weatherman 5'x115',9'x125',and 10'x125'rolls.Product wei ht is Drainable and Portland cement.stucco of mo'rtarused in masonry approximately 2.25 lbs/100 sq.ft. g veneerwalls. the Internadanal Code Installation:WeatherSmart Drainable should be installed in Applicable Standards:Complies with accordance with the local applicable building code.Weather- Council Evaluation Services Acceptance Criteria for Water resistive barriers should be applied horizontally,with the upper Resistive Barriers(AC 38). layers overlapping the lower layer by a minimum of 6",and Complies as an alternative to the water-resistive barrier a!!vertical joints should be lapped a minimum of 12".Consult specified in Section 1404.2 of the International Building Codee. your design professional where necessary. Complies as an alternative to the weather-resistant sheathing Availability:The Fortifiber Building Systems Group' products papers specified in Section R703.2 of the International are distributed nationwide.For product information and Residential Building Code®, pricing,please call a Fortifiber distributor near you.If you need ICC-ES Evaluation Report No.3791. assistance locating a participating distributor,please call our Customer Service Department at 1-800-773-4777. American Society for Testing&Materials(ASTM); Fortifiber Y'lartantj:This product maybe eligible for ASTM D 779-Standard Tort Method for Wm rRuirtance Fortifiber's FortiShie)d IS year warranty when used in ofPaper,Paper board and Other Sheet Materials by the Dry conjunction with other Fortifiber products.Please see our IndicatorNletbod website at www.fortifibercom/wan-antyhtm for details. • ASTM D 5034-Standard Tut Method far Breaking Strength Fortifiber Corporation warrants that its products are in and Elongation of Textile Febria(Grab Ten) compliance with their published specifications and are free from •ASTME 84-Standard Test Metbod far Surface Burning defects in materials and workmanship for a period of two years Chanuterinia of BuAling Materiak from the date of purchase.This warranty does not apply to loss •ASTM E 96-Standard Test Method for Water Vapor due to abuse.Material found to be defective will be replaced at Trannuisrimr ofMateriolr no charge by Fortifiber,but in no event shall Fortifiber be liable for any other costs or damages,including any labor costs.•ASTME 2178-Srmrdm d Test Method for Air Penarrmuc of IMS EXPRESS WARRANIYrS GrM r I N LIEU OF AND EXCLUDES Building Matniak ALL OTHER EXPRESS OR INer-MD WARRANL mE5,7i rCLUDING •AS7N E 2273-Standard Tat Method jot•Deternsining the BZTP Nar Lfi01IfED TO'TEIE SeL1ED WARRANTIES OF Drainage Efficiency of Exterior•iiunlation and Finish Synew MERCH&WABILTIYAND F171-NF-SS FOR A PARTICULAR PURPOSE. OHM Glad Wall Asnnrbfia Fortifiber's sole obligations under this warranty are as set forth herein.In no event shall Fortifiber be liable forvany lost revenue Physical Properties:WeatherSmazt Drainable is continually da profits,direct,iadirect,special,incidental of consequential tested in accordance with ASTM procedures.The values shown in Table I are averages obtained in these tests, damages of any kind. • . Table I-P4D(dcal P.Vevties Drainage ASTM E Z2273 )95% >9096 Efficienry Pass a Moisture Vapor ASTM E 96 Procedure 105 g/smaday 35 g/smaday transmission A(Desiccant Method) 05 perms) ( InFmum) • +' ' • •+ •. + AlrPermeance ASTM c0.02Vs/sgM I c0.02VtasgM • . .. . + , at 7s Pascals Dry Breaking Force ASTM D S034 MD-Si Ib+ JCD D-40 lb, (Gab Test)I [CD-40 It, -3516, + Water Resistance ASTM D`779 >60 min 10 min(minimum) Class A Class A Flame spread ASTM E 84 0-Pass 0-25 Smoke Developed ASTM E-84 20-Pass 00450 Fortifiber Building Systems Group, JfProtecting Your World from the Blemetstsm Call1-800-773-4777or1-775-333-6400•www.fortifibercom. O+eg raRiab•.r auad&ra System•GNUP•.Porn6bwtr,*raSh W*JAoWcp1Sea190kh•1ecr02%WWa1d Gem Ibe rkmcW aedWsalbaS,at-ars dadrn ks GfWlfiba C0gXMiWL WINDOW INSTALLATION Due to the advanced drainage fea- tures of WeatherSmart Drainable, All lashings must different installation methods are be a minimum of 9' required, It is important to follow ""de' �Window these instructions to ensure propernamewith sealant seal around windows and doors. This"Method Al"for Head weathersmart Modified WeatherSmart Drainable Installa- " flashing Drainable Rough Weather tion guide is designed for S integral OP=ng barrier g See Fig.9a for i daSr flanged window applications, proper methods of Inlegrwhere the window is installed after flashing and ad the weather-resistive barrier MWe the and (WRB)is applied. Compliance with Drakable, the building code and proper installation are critical in reducing ° s potential water leakage points. Jamb g p dashing a Consideration should be given to er preparing the substrate, including wnrdow comer shield cleaning the window flange and Patch making sure the surfaces are dry and free of any debris. For best adhesion, an approved primer and J-roller are recommended. The following Fortifiber Building Systems Groups products are recommended for this method. •FortiFlash®Flashing, FortiFlashO Commercial Flashing or FortiFlashe Butyl Flashing •Moistope Sealant and liquid Flashing •Moistop®Corner Shield •FortifiberODPrimer -WeatherSmart®Drainable INSTALLING THE . ._ install WeatherSmart Drainable over an approved exterior sheathing. Starting at the ° bottom of one end of the wall,place the WeatherSmart Drainable roll horizontally (overlapping the comer by a minimum of 12'� and roll out the first course evenly, wrapping over the window and door rough openings. ° Begin rod minimum Place the membrane so that it is light and o of1 'awa2awa g y flat from comer ° ° ° 0 0 s °o i FASTENING 3 SEAM As VERTICAL HORIZONTAL 0 0 0 1'mmed o 24'O.C. will staples that ° 0 6, a max. c penetrate 12'minimum recommended 0 o studs. o vertical horizontal (optional) 0 o �p 0 0 0 :✓✓J Fortirlber recommends using fasteners with 1"plastic caps, or using I'crown staples that penetrate the _ studs to attach WeatherSmart Drainable so that it is taut and Bat The proper spacing for these fasteners is 24"on center,maximum. Closer spacing may be At vertical seams, apply Any succeeding course required based on site conditions. a minimum 12"vertical should be placed horizon- overlap. When going tally over the lower course around comers, make in a weather-board fashion sure WeatherSmart with a minimum horizontal Drainable is pulled tight- overlap of 6". ly and properly fastened. 14 MODIFY THE WRB CORNER SHIELD ° -bead ofMolstop APply a%'bead of Sealant Mofstop Sealant and Trim to fit sltl Liquid Flashing as shown and embed the as ° top edge of the Moistop ' method 0 0 Corner Shield.Install o atraugh fasteners into the face to openings secure. Trim to width of ° ° sill with sharp utility Fastenersa knife. Molstop o ° Sld At the rough opening, out the housewrap in an inverted"Y" fashion.Make diagonal cuts at the top of the rough opening comers.Example:for 9"flashing measure as follows.9"up and T over, 45°angle(a). Cut on the diagonal from marked Point to the rough opening comer. Raise the top edge of Me WeatherSmart Drainable and tape the comers and the center to the surface above. This will allow for the installa- tion of the window, the jamb and head flashing later. 0 SILL FLASHING CORNER • i TCHES Ad liashhtg Irerticelhere cuts shouts be Jirmiy rolled using a,Ff, v Comer I Patch Fold nto ' s SM SSM Uas/ring \ 6'x 9*Comer R.D.+2x wldUr patches compietly ofjamb flashing covers the Comer Shield piece. Cut the sill flashing to the width of the rough opening Cut two comer 65(91 comer patches using 9"flashing. Plus twice the jamb flashing width. (R.O. +2x width Install comer patches over each Moistop Comer of jamb flashing). Remove the release paper and Shield at the jambs. install the sill flashing in place- Make a vertical cut at each jamb and fold the flashing onto the sill. Once in place, aN flashing should be firmly rolled using a J-roller. JAMB FLASHING W E A/ Jt Apptycontlnuous Finch bead of sealant on window flange. r r I Extend Jamb fiba NrU1dOW from the t, 2'draina &gap flange of Ute head Before installing the window, apply a 3/a" bead of 'fir' g gashinainst Me g 9ashkty. Moistop Sealant and LiquidFlashing to the backside f% �"�frame wth the adhesive slr, (interior)of the mounting flange leaving two 2"drainage C.donangee tPm gaps at the sill.Install the window according to the win- dow manufacturer's instructions. ; t OO' Jamb flashin t Prior to installing the jamb flashing wipe the jamb flange and WeatherSmart Drainable to ensure proper adhesion. Then cut two strips of flashing long enough to extend l"beyond the sill flashing and T below the top of the head flashing. Remove the release paper and align the flashing flush against the window frame with the adhesive strip covering the entire window flange. Follow this procedure for the other side of the window. 0 110 HEAD FLASHING Aibw�uy head Align H►a Hashing flush aggainst the flashir�g tto prop rly seal window frame wrth the a8hesive ship jamb(lashing. Appply 4`marimum covering the a windowdng the window flange• F�tZFWh over entire dragortaI cuts 6r ' weether-restsfive barrier f' Head flashing ' Wlpe the head flange, and jamb flashing.Cut a piece of Finally, allow the flap of the weather-resistive barri- flashing long enough to ensure that the head flashing er at the head to lay flat over the head flashing. Cut extends a minimum of I"beyond the jamb flashing. Install a piece of 9"flashing to make two diagonal patch- the head flashing by pressing firmly in place in one direction es and install over the entire diagonal cut made in to prevent voids. Once in place, alt flashing should be the weather-resistive barrier and roll firmly in place. finely rolled using a J-roller. BACK D , OVERVIEW Provide a back dam Thls recommenda- _ min, and air seal to the bon refers to the inside of the rough most commonly opening. The configu- used types of win- ration of the back dows(surface j itt dam will vary based mounted). For other on the profile of the types of frames, window being special attention 1111 ( installed. should be paid to the window manu- facturer's instruc- tions. Windows,window flashings and weather barriers must be properly integrated in order to form a comprehensive moisture control system. The windows shown in this guide follow the Method"Al"window installation and refer- ence the AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION. Also,you can find other detailed instructions on how to integrate weather barriers and window flashings at www.fortlfibercom Limitations:WeatherSmart Drainable should be covered within 120 days.inspect product to ensure it is free of any protrusions or damage which may detract from the Fortifiber Building weather resistive barrier integrity.Holes,tears or punctures should be sealed with Systems Group® Molstop Sealant or Fortiflber Sheathing Tape.This product is not recomended for horizontal,roofing or below grade applications.Ensure that a layer of Super Jumbo Protecting Your World f vm the Elanenu' Tex 60 Minute is used to separate weathersmart Drainable and Portland cement stucco Or mortar used in masonry veneer walls. NATIONAL SALES OFFICE Reno,Nv pRy,p 0 7. 777777777-77.: 77777777777F7 _.: i •� (1iJ''�''' 7 -� , �� #:� `'i y �"� `'L' •wy M, gf't .t yy,.n, ;�:q.,J ;'S•..t'. ;:.:f� � '•1 : .=� 1 .'` < 1 _ � ��- � �4' h �C` �'� w Yz r� ry`,� �Tr AGGRESSIVE,TACKY ADHESIVE AIDES IN SPLICING TO VARIOUS NON-SILICONE SURFACES. STRONG PET CARRIER ADDS DIMENSIONAL STABILITY AND STRENGTH. •;' .MSK T4�'� .. EXCELLENT BALANCE OF TACK,PEEL,AND TENSILE .�% �• STRENGTH. c` MAINTAINS ADHESION AT LOW TEMPERATURES. r'' " EXHIBITS EXCELLENT AGING AND WEATHERING ? x ~r PROPERTIES. PROVIDES AN OUTSTANDING SEAM AND LAP SEAL. MAY BE APPLIED DOWN TO 107(-10°C). DESIGNED FOR USE WITH HYDRO TEX JUMBO TEX PLYDRY;WEATHERSMART°AND WEATHER TEXO WEATHER RESISTIVE BARRIERS. 1939 - Property Fortifiber Sheathing Tape Roll Dimensionsi 17/8-x S5yards;3-x SSyards .z Adhesive Acrylic Backing Coated Polyester Film Peel Adhesion(stainless steel) 20 oz/inch Tensile Strength 37 lbs./inch Elongation 110% Fortifibear Building Systems Grou a Calla-800-773-4777 ori-775-333-6400 Protecting Your lVortdfrmrs the Elewteretso for sales and technical assistance. On the Internet visit www.fortifiber.com. '�30lJrali$bv�7Ci139p1em3Gap�.ioniFx•.�;,dprcY'•Le•!A&P.iljlkj�.T.IK,i�riuYAulESov.U!&T.aNf`.Y.7�Ih'4Rurliardi•Cama'x•xwemavndsrxrer`-Axa.,,�K HardiePlank- "721-0. Lap_ Siding 7A 4 JamesHardie INSTALLATION REQUIREMENTS-PRIMED&COLORPLUSe PRODUCTS V�itwww.harraeiraslaNac EFFECTIVE MAY 201IM most 6 SELECT CEDARMILL°•SMOOTH•CUSTOM COLONIAL"SMOOTH•CUSTOM COLONIAL"ROUGHSAWN CUSTOM BEADED CEDARMILL°•CUSTOM BEADED SMOOTH•STRAIGHT EDGE SHINGLE PLANK IMPORTANT FAILURE TO INSTALL AND FiNISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY,AFFECT SYSTEM PERFORMANCE,VIOLATE LOCAL BUILDING CODES,AND VOID THE PRODUCT ONLY WARRANTY.BEFORE INSTALLATION,CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONEna PRODUCT INSTRUCTIONS. INSTALLATION OF HZ106 PRODUCTS OUTSIDE AN HZ10a LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONE"a APPLIES TO YOUR LOCATION,VISiT WWW.HARDIEZONE.COM OR CALL 1-666-942-7343(866 9HAROIE) STORAGE&HANDLING: m CUTTING INSTRUCTIONS Ston:flat and keep dry and covered prior OUID00NS to installation.Installing skiing wet or 1.Fb*m oft aWM so that Hind tv0 blow U evraybam user I.Cut ady using scare and snap,orshears(ro nwl,ekft a saturated may result In sfuinkage at butt and°�In haft area 2.Position cutting stationNwall-venl7ated area pneumatic).Ionise Cacy phinks on edge.Protect Z the ore d the bu*g m edges and comers from breakage.James a Beat a 9=0 am�orAw. -- ----- Hardie Is not msponsINe for damage h Bene L Dust a aft an i t VER use a pourer sour inions caused ire redt�gdaeesaw VAa -�1liseackularsaavtiadenWdvsnot tfem savrldadetradertnada by proper storage and hand ft itartfe8 saw tYade enc!HB',q rarwm eabacdon -*W dry s wep—tka wet suppression or ttEPAvaarom of the product. aGood: LDust reddgcircular sarevmhat desmvWe :r 0*use hrluvtomoderate m" —moi==�,��;• ..~ InpalarttNakfwmadrnan PmWknttraestnmspira�eduspoductiordJames RRUre aksysUsing'Besr-kvd anidg rnNlntls where feasus. NOSH-apptowedfdWV&rs can be used In caitaztim with above aft pra*es to furtherrela dist mostm Addaiora► at wm4 m card exon to help pi delennile the most �e r=adon is avatbis dorrotmrrpywith the above pacntes.you shoukiaFmethadtayaraJcbrer�aartrenLsnaxxemsNeosfszbgNRer�srraleetsatou Hasstanninag1AQh'i4ral4orcoatzetJames manse forbftr*nmton. GENERAL REQUIREMENTS: • HardiePiank`lap siding can be installed over braced wood or steel studs spaced a maximum of 24 in,o.c.or directly to minimum 7116 in.thick OSB sheathing.See general fastening requirements.Irregularities in framing and sheathing can mirror through the finished application. • Information on Installing James Hardie products over foam can be located in JH Tech Bulletin 19 at twrw,iamehardie com • A water-resistive barrier is required in accordance with local building code requirements.The water-resistive barrier must be a th penetration and junction flashing in accordance with local building code requirements.James Hardie will assume no responsibility water Infiltration. James Hardie does manufacture HardieWrap°Weather Barrier,a non-woven non-perforated heusewrap',which compiles with buildkmg rode requirements. • When instairmg James Hardie products all clearance details in figs.3-14 must be followed. • Adjacent finished grade must slope away from the building in accordance with local building codes- typically a minimum of 6 in.In the first 10 ff.. Double wall • Do not use HardiePiank lap siding in fascia or him applications. Figure 1 construction single watt • Do notinstall,lames Hartle products,such that conrhuceon they may remelt in contact wwi standing water araler resLsave Ozrrrer let-in tea • Harditmt'lank dap siding maybe Installed on flat vertical wall appllrations Drily. 24 b.o.r:max • For larger projects,including commercial and multi-family projects,where the span of the o�e wall Is significant in length,the designer and/or architect should take into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be[mind in the Technical Bulletin"Expansion Characteristics of James Hardie°Siding Products"at www.JamesHardie.com. • 00 NOT use stain,o'Vaikyd base paint,or powder coating on James Hardie°Products. INSTALLATION: JOINT TREATMENT One or more of the following Joint treatment options Figure 2 Nora Mae(G vena ' are required by code(as referenced 2009 IRC slid Gee"not R703.10.4resent place A.Jona Flashbtg(James Hardie recommended) be�h7 3/4 B.Caulift'(Caulking is not recommended �� top of tor. 7,314 1"a* for Cobft for aesthetic reasons as the Caulift and ColorPlus vrlil weather dlffem*.For the same reason, °D ,° ware-reslsWe do not caulk nail heads on barrier D CobrPius(xaducts.) Hard dePiardc'� • D ►aslerer C."H"IOlder Cuter o°°° 000 tmhaa 11/4 In starter strip to moderate Installeduaact at ihun)*is °o o° easaeaConsistent plank angle tone appropriate gap babveen nbriarrd nn,then awk-- Note:Reg painting over caulldng may Produce a sheen difference when compared to the Geld painted PdmePhs. 'Refer to Caulking section in Use instruction 'For addl6aral Information on Hardiftap°WeaUter Banner,consult James Hardie at 1-856.4Nardle or wwwhaNlewrap.com WARNU41;:"O)D BREATHING-SILICA DUST James kande°prointi a essive amounts respirable aystalhte staca wt car is brain ro ane ate N Cautorrda ro pane miner and 6 eaiskdered br WIC and NOSH to be a arise of carza sources.iDead rea a thesfee . OW of r hake sMlca dust can elm ease a a and potand*nalar hog disease MW sem,and has been adorn other dseases�sides pest smddrgmayNaeasealae risla. OtaVrQ stinum a hardb :(1)work In"'areas wb able—titauat M use Gberceraent ft=for wrong a,whoa not r=*10.uu alba9L�de°sawblade aaztt151-reNchg clrpAar Baty atlagned la a tfEPA vaasmr, worm ogars n the(rnmedate areal{4)wear a praperyGtOed.N�f{.approved dull mask orresp4atar(e.g.N-g5}n arop�w� b 9aanua3oiragtianorrsandmaaahc4aerirstmctlonslofuinitresptabks�,a .Our6ngdan use ttFPAvaarrmsawet mdhods-novedrysweep,rvpr�� a4SrislLAit4Sfq(P P;bty SAD�SIS avalabde al wwwD. dbcom a by ca�aj�j.aeO-�A�IE epO-942-734 r•All11F>E TD At>}�E TO OIA w i'�ONAi.euuar at Til. p- � -ReYGS,MSOS: k511119-Pt14 05!16 y ro CLEARANCE AND FLASHING REQUIREMENTS Figure 3 Figure 4 Roof to WallHorizontal FlashingFigure 5 Figure 6 Kickout Flashing Slabs,Path,Steps to Siding 2-Flashing As tequiked 4Kxx Min.Y4 in.Do not caulk r' _. 1 hh.-26n. Figure 7 Figure a Figure 9 Deck to Wal! Figure 10 Figure 11 Ground to Siding Gutter to Siding Sheltered Areas Mortar/Masonry Z- hing --r 'Z-Flashing -Flashing , f Z-Fl llngl Mh A In. .; -- Min.%in. Figure 12 Figure 13 Figure 14 Drip Edge Block Penetration Valley/Shingle Extension z ,• - ln.16 dlti ' r y�.t tt. FASTENER REQUIREMENTS** Blind areas anddmmust not be used in corm Insulation is the Preferred method of for HardiePiank,lap yldtng products.Face riding should�[y be used where required by erode icrtdgh wind done for aesthetic )unction with Blind naNng(Phase see JH Tech bulletin 17 for exemption When doing a re.Pin-backed comers may be purposes Only.Pin-backs shalt be done with finish nags only,and are not a substitute for blind or face nailing. BLIND NAILING Nails-Wood Framing FACE NAILING •Siding nail(0.0910.shank x 0.221 In.HD x 2 in.long) Nails-Wood Framing e 11ga.roofing nail(0.121 In.shank x 0.371 in.HD x 1.25 In. •6d(0.113 In.shank x 0.267 In.HD x 2 in.long) Screws-Steel Framing 9 nerl(0.09 In.shank x 0.221 in.HD x 2 in.lord •Ribbed Wafer-head or equivalent(No.8 x 1 Screws-Steel Framing 1/4 in.long x 0.375 in.HO)Screws Robed Bugle-head err equlyalant(No.818 x 1-518 b�x must penetrate 3 threads into metal Naming. Nails-Steell Framing 0.323 In.HD)Screws must penetrate 3 threads Into mineral framing. ET&F Panelfast'nails or equivalent(0.i 0 lin,shank x 0.313 in HD x i-1/2►n. Nails Ell 8 F pin or equly-anent(0.10 in.shank x 0.251n.HD x 1-1/2 in.long) long)Nags must penetrate m4nlmum 1/4 10.into metal NNails must framing. penetrate minimum 1/4 in.Into metal framing.OSB minimum 7/16 in. OSB minimum 7/16 in. •11 ga.roofing nail(0.121 in.shank x 0.371 in.HD x 1.75 in.long) •Siding nail(0.09 in.shank x 0.221 in.HD x 1-1/2 tin.long)• •Ribbed Wafr-head or equivalent(Nn.8 x 15/8 in.long x 0.375 in.HD). surd 241 Said W O.C.max O.C.max Figure 15 Figure 16 114 h min. Minimum overlap °rodaa for Both Face ' Nag tsa°� and Blind Nailing -�� o min.1114 M. mac°naa i ovedep i VWkr Reaisv.e 1t U� atv,� Banter baffW ° Laminate sheet to be removed immediately after installation of each course for ColorPluse products. When face rhatilrtg to 0SB,planks must be no greater than 91/4 In.wide and fasteners must be 12 in.o.c.or less. ^Also see Geruer�raslixning Requkemenl and when considering aftemalive taste ft Woos rater to dames Hardie TWv tql Belau LM 17-Fastening Tips for%*pW*°LapSlft. HS111t9,m 0-Yt6 y >o GENERAL FASTENING REQUIREMENTS PNEUMATIC FASTENING Fasteners must be conaston resistant,galvanized,or stainless steel. James Hardie products can be hand naled or fastened A a pneumatic tool. Electro-galvanized are acceptable but may exhibit premature corrosion. Pneumatic fastening is highly recommended. Set ak pressure so that the James Hardie recommends the use of quality,hot-dipped galvanited nails, fastener is driven snug with the sexface of the siding.A Bush Haunt James FPardle is not responsible for the corrosion resistance of fasteners, attachment on the pneumatic tool Is recommended.This will help control the Stainless steel fasteners are recommended when Installing James Handle° depth the nail is driven.If selling the nal depth proves difficult,choose a products near the ocean,large bodies of water,or in very humid climates. setting that under drives the nail. (Drive under driven oak snug with a Manufacturers of ACO and CA preservative-treated woad recommend spacer smooth faced hammer-Does not apply for Installation to steel framing). materials or other physical barriers to prevent direct contact of ACO or CA preservative-treated wood and aluminum products.Fasteners used to attach HardleTrim Tabs to praservadve-treated wood shall be of hot dipped fill&a d nail zinc-coated galvanized steel or stainless steel and in accordance to 2009 IRC snug flush fill&add nail R317.3 or 2009 IBC 2304.9.5. 100 NOT DO NOT Figure A Figure B under drive nails staple • Consult applicable product evaluation or listing for correct fasteners type and placement to achieve specified design wind loads. PAINTING • NOTE:Published wind toads may not be applicable to all areas where Local DO NOT use stain,oiVaflryd base paint,or powder coaling on James Hardie® Building Codes have specific jurisdiction.Consult James Hardie Technical Products.James Hardie products must be painted within 180 days for primed Services 9 you are unsure of applicable compliance documentation. product and 90 days for unprimed. • Drive fasteners perpendicular to sling and framing. y pn topcoats are recommended. • Fastener heads should fit Do not paint when wet.For application rates refer bo paintt manufacturers snug against siding(no air space).(fig.A) specifications.Back-rolling is recommended if the siding Is*rayed. • Do not over-drive nag heads an • If nail is comtersu*ntnag hole and add a nail .(fffge CUT EDGE TREATMENT • For wood framing,under driven nails should be hit flush to the plank with a Caulk,paint or prime all field cut edges.James Hardie torch-upkits are hammer(Por steel kaming,remove and replace nail. required to touch-up ColorMus products. • NOTE:Whenever a structural member Is present HardlePlank should be fastened with even spacing to the structural member.The tables allowing CAULKING directtonot OSBble.or p� results use an Elastomeric Joan eod should only be used when traditional framing is For best lSealant complring with ASTM C920 • Do not use aluminum fasteners,stir Grade NS,Class 25 or nigher or a Latex Joan Sealant complying with ASTM pies,or clipped head nails. 0834.Caulking/Sealant must be applied In accordance with the caulldng/sealant manufacturer's written Instructions.Note.OSI Quad as well as some other caulking manufacturers do not allow tooling. COLORPLUS®TECHNOLOGY CAULKING,TOUCH-UP&LAMINATE •Care should be taken when handling and cutting James Hardie®ColorP USO products.During installation use a wet soft doth or soft brush to gently woe off any residue or construction dust left on the product,then rinse with a garden hose. •Touch up alcks,scrapes and nail heads using the Col&s*Technology touch-up applicator Touch-up should be used sparingly. If large areas require touch-up,replace the damaged area with new HardlePlanW lap siding with CoWfus Technology. •laminate sheet must be removed Immediately after Installation of each course. •Terminate ran-factory cut edges into trim where possible,and caulk.Color matched caulks are available from your ColorPhus'product dealer. •Treat all other non-factory cut edges using the ColorPlus Technology edge coaters,available from your Cobrpius product dealer. Note:James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems w9h aPPearence or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hato lexh-up will not be covered under the James Hardie ColorPlus Limited Finish Warranty. PAINTING JAMES HARDIE®SIDING AND TRIM PRODUCTS WITH COLORPLUS°TECHNOLOGY When repalndng ColorPhrs products,James Hardie recommends the following regarding surface preparation and topcoat application: •Ensure the surface Is clan,dry,and free of any dust,dirt,or mildew •Repriming Is normally not necessary •100%WOO topcoats are recommended •00 NOT use stain,OlValkyd base paint or powder coating on James Han:110 Products. •Apply finish coat in accordance with paint manufacturers written Instructions regarding coverage,application methods,and application temperature •00 NOT caulk nail heads when using ColorPtus products,refer to the CotorPlus touch-up section NS11119-P314 05116 /Fr 1 .19 COVERAGE CHARPESTIMATING GUIDE Number of 12 It planks,does not include waste COVERAGE AREA LESS OPENINGS HARDIEPLANr LAP SIDING WIDTH 5Q51M 6 V4 7114 7112 8 8114 9114 9112 12 (1 SO-100 sq.IL) (eicposura} 4 5 6 6114 6 314 7 8 8114 10 314 1 25 20 17 16 15 14 13 13 9 2 50 40 33 32 30 29 25 25 19 3 75 60 50 48 44 43 38 38 28 4 100 so 67 64 59 67 so 5o 37 5 125 100 83 80 74 71 63 63 47 6 150 120 100 96 89 86 75 75 56 7 175 140 117 112 104 100 88 88 65 8 200 160 133 128 119 114 100 100 74 9 225 180 150 144 133 129 113 113 64 10 250 200 167 160 148 143 125 125 93 11 275 220 183 176 163 157 138 138 102 12 300 240 200 192 178 171 150 150 112 13 325 260 217 208 193 186 163 163 121 14 350 280 233 224 207 200 175 175 130 15 375 300 250 240 222 214 188 188 140 16 400 320 267 256 237 229 200 200 149 17 425 340 283 272 252 243 213 213 158 18 450 360 300 286 267 257 225 225 167 19 475 380 317 304 281 271 238 238 177 20 Soo 400 333 320 296 286 250 250 186 This coverage chart Is meant as a guide.Actual usage Is subject to variables such as building design.James Hardie does not assume responsibility for over or under ordering of product RECOQ M-.Nammdrnce Mdb ICC-ES Evafualm RePMESR 2290.Han"l"bF d ft Bre=Pf0d as a sub&*=*to ftgxoW kc he 2006,WAM12 Wema6onal RtWmWCc6 for One. ;yd lYro-x*Dxe6gs and dw2006,2009,t2012(nnlandBaditCuk-RmWlNdcfa fto Is abe morimdraappWmN8xblovring:ChotlnsAn2duReswdRepodkU16ftwd Florida151MFl,d889DadeCaoFbftNDA No.QW2UZU.B.Dep.dHUD hWeddsRelesseUSX Tan DrparhWofKw aPmdodevgomECaCirdtkwYakhffAU393H,andCftWa 0SAW019.TAesedo=WASehmW*Dbeconm0edroredd wdWmeonconoM*gfiremiaWor#6WohdWspertapp6ca5M 02D16JamesHmbBftVPn>*ft AfftW serwW. Additionallnstallalkn TK Information, Jw ski:and® 6a tkdw sQ is amgb badanarks W o JxnasHa�oTedrdogyLhRed,Bkareghlertdiraftgrk Wanarlties,ar►dWarningsareavailableat www.jwmhxde.com T Of JaJamesNardie mes eA1*r 1te11ed, al mhxdie.com PanaBacl k a Ia9liWed badamerk d ETSF Fm�neg Spsteoq Inc, HSt1119.P4M 0546 PARR LUMBER CO-WANKERS CORNER PARR 2351 SW Borland Rd. !]mom West Linn,OR 97068 f L U M B E R 503-638-7575 Quote Name: Hampton Ridge-Bldg 5 Quote Number. SQPATKO02325_1 Customer: Lifetime Exteriors Created Date: 4/29/2022 Payment Terms: Modified Date: 4/29/2022 Sales Representative: Kevin Conner Mobile: PO Number: kevin.conner@parr.com Total Windows: 44 Weighted Average: U-Factor:.27,SHGC:0.3,VT:.56 Total Doors: Total Sq Ft: 960.00 Comments: Total Perim Ft: 856 For warranty information please visit www.mil ard.com warran ptj Est.Delivery: Billing Information Shipping Information Name: Lifetime Exteriors Name: Address: Address: Phone: Phone: Fax: Fax: Email: Email: Line: 1 Location: Quantity: 2 Style Line V250,6110,HV,13/8"Setback,Ext White/Int White,U-Factor:.27,SHGC:.30,VT:.56 $235.24 3/32"SunCoat(Low-E) over 3/32"4th Surface HP Coating $37.41 Operating Control Device $23.06 Fresh Air Flow Vent $36.90 Tariff $1.62 Model=Half Vent Item Total: $334.23 1 ""Size=RD:48x 48 � Line Total: $668.47 7 Net Frame:471/2"x 471/2" f j i I Handing=XO ! Glass=3/32"SunCoat(Low-E)over 3/32"4th Surface HP Coating with Gray EdgeGardMAX Spacer Glazing=Dual Glaze Hardware=Window Opening Control Device,Positive Action Lock Other Options=Fresh Air Flow Vent Screen=Standard with Fiberglass Mesh Ci � Ratings=STC:No Rating,OITC:No Rating,PG:LC30 I Clear Opening=W 211/8"x H 45"Sq.Ft.6.6,Egress:Yes Other Ratings=CPD:MIL-A-153-07526-00001 Viewed From Exterior Customer Approval: Quote Number: SQPATK002325_1 Print Date:4/29/2022 Page 1 of 6 gine: 2 Location:NON-TEMPERED Quantity: 8 Style Line V250,6210,DSH,13/8"Setback,Ext White/Int White,U-Factor:.27,SHGC:.30,VT:.56 $457.15 3/32"SunCoat(Low-E) over 3/32"4th Surface HP Coating $58.94 Operating Control Device $46.12 Fresh Air Flow Vent $36.90 Tariff $1.62 Model=Single Hung Two Wide Item Total: $600.73 Size=R0:60"x 60" Line Total: $4,805.86 Net Frame:591/2"x 591/2" Dimensions=Sash Height:One Half f ! Composite Method=Vertical:IMR Glass=3/32"SunCoat(Low-E)over 3/32"4th Surface HP Coating with Gray EdgeGardMAX Spacer Glazing=Dual Glaze Hardware=Window Opening Control Device,Positive Action Lock Other Options=Fresh Air Flow Vent ! Screen=Standard with Fiberglass Mesh Ratings=STC:No Rating,OITC:No Rating,PG:LC30 Clear Opening=W 271/4"x H 26 3/8"Sq.Ft.4.99 Other Ratings=CPD:MIL-A-154-07519-00001 Viewed From Exterior Customer Approval: Line: 3 Location:TEMPERED-LEFT Quantity: 5 Style Line V250,6210,DSH,1 3/8"Setback,Ext White/Int White,U-Factor:.27,SHGC:.30,VT:.56 $457.15 Custom Glass Option $153.24 Operating Control Device $46.13 Fresh Air Flow Vent $36.90 Tariff $1.62 Model=Single Hung Two Wide Item Total: $695.03 — Size=RO:60"x 60"� Line Total $3,475.16� Net Frame:591/2"x 59 1/2" Dimensions=Sash Height:One Half �f� I Composite Method=Vertical:IMR Glass=SH 1.1 Lower Left Vent,SH 1.1 Upper Left Fixed:1/8"SunCoat(Low-E)Tempered over — 1/8"4th Surface HP Coating Tempered with Gray EdgeGardMAX Spacer,SH 1.2 Lower Right Vent,SH 1.2 Upper Right Fixed:3/32"SunCoat(Low-E)over 3/32"4th Surface HP Coating with Gray EdgeGardMAX Spacer Glazing=Dual Glaze Hardware=Window Opening Control Device,Positive Action Lock T Other Options=Fresh Air Flow Vent Screen=Standard with Fiberglass Mesh Ratings=STC:No Rating,OITC:No Rating,PG:LC30 Clear Opening=W 271/4"x H 26 3/8"Sq.Ft.4.99 Other Ratings=CPD:MIL-A-154-07520-00001 Viewed From Exterior Customer Approval: Quote Number: SQPATKO02325_1 Print Date:4/29/2022 Page 2 of 6 lne: 4 Location:TEMPERED-RIGHT Quantity: 5 Style Line V250,6210,DSH,13/8"Setback,Ext White/Int White,U-Factor:.27,SHGC:.30,VT:.56 $457.15 Custom Glass Option $153.24 Operating Control Device $46.23 Fresh Air Flow Vent $36.90 Tariff —— Model=Single Hung Two Wide $1.62 Item Total: $695.03 Size=RO:60"x 60" Line Total: $3,475.16 Net Frame:591/2"x 591/2" �� 11 Dimensions=Sash Height:One Half 4 i ; Composite Method=Vertical:[MR Glass=SH 1.1 Lower Left Vent,SH 1.1 Upper Left Fixed:3/32"SunCoat(Low-E)over 3/32"4th Surface HP Coating with Gray EdgeGardMAX Spacer,SH 1.2 Lower Right Vent,SH 1.2 Upper Right Fixed:1/8"SunCoat(Low-E)Tempered over 1/8"4th Surface HP Coating Tempered with i M Gray EdgeGardMAX Spacer Glazing=Dual Glaze Hardware=Window Opening Control Device,Positive Action Lock Other Options=Fresh Air Flow Vent Screen=Standard with Fiberglass Mesh Ratings=STC:No Rating,OITC:No Rating,PG:LC30 Clear Opening=W 271/4"x H 26 3/8"Sq.Ft.4.99 Other Ratings=CPD:MIL-A-154-07519-00001 Viewed From Exterior Customer Approval: Line: 5 Location: Quantity: 10 Style line V250,6210,DSH,1 3/8"Setback,Ext White/Int White,U-Factor:.27,SHGC:.30,VT:.56 $500.20 3/32"SunCoat(Low-E) over 3/32"4th Surface HP Coating $70.21 Operating Control Device $46.13 Fresh Air Flow Vent $36.90 Tariff $1.62 —-- —_ --- Model=Single Hung Two Wide Item Total: $655.06 Size=RO:72"x 60" Line Total: $6,550.58 I Net Frame:711/2"x 591/2" Dimensions=Sash Height:One Half Composite Method=Vertical:IMR t! I Glass=3/32"SunCoat(Low-E)over 3/32"4th Surface HP Coating with Gray EdgeGardMAX Spacer i; Glazing=Dual Glaze j !} Hardware=Window Opening Control Device,Positive Action Lock Other Options=Fresh Air Flow Vent Screen=Standard with Fiberglass Mesh Ratings=STC.No Rating,OITC:No Rating,PG:LC30 Clear Opening=W 331/4"x H 26 3/8"Sq.Ft.6.09,Egress:Yes Other Ratings=CPD:MIL-A-154-07519-00001 Viewed From Exterior Customer Approval: Quote Number: SQPATKO02325_1 Print Date:4/29/2022 Page 3 of 6 f rne: 6 location: ,Quantity: 8 Style Line V250,6210,SH,13/8"Setback,Ext White/Int White,U-Factor:.27,SHGC:.30,VT:.56 3/32"SunCoat(Low-E) over 3/32"4th Surface HP Coating $234.73 Operating Control Device $35.36 Fresh Air Flow Vent $23.06 Tariff $36.90 Model=Single Hung $1.62 Item Total: $331.67 Size=RO:36"x 60"� Line Total: $2,653.36� I Net Frame:351/2"x 591/2" f Dimensions=Sash Height:One Half Glass=3/32"SunCoat(Low-E)over 3/32"4th Surface HP Coating with Gray EdgeGardMAX Spacer Glazing=Dual Glaze Hardware=Window Opening Control Device,Positive Action Lock j Other Options=Fresh Air Flow Vent Screen=Standard with Fiberglass Mesh j Ratings=STC:No Rating,OITC:No Rating,PG:LC35 I Clear Opening=W 33"x H 26 3/8"Sq.Ft.6.04,Egress:Yes Other Ratings=CPD:MIL-A-154-07519-00001 Viewed From Exterior Customer Approval: Line: 7 Location:TEMPERED Quantity: 2 Style Line V250,6210,SH,13/8"Setback,Ext White/Int White,U-Factor:.27,SHGC:.30,VT:.56 $213.20 1/8"SunCoat(Low-E) Tempered over 1/8"4th Surface HP Coating Tempered $124.03 Operating Control Device $23.06 Fresh Air Flow Vent $36.90 Tariff Model=Single Hung $1.62 Item Total: $398.81 Size=RO:30"x 60" Line Total: $797.62 Net Frame:291/2"x 591/2" i Dimensions=Sash Height:One Half Glass=1/8"SunCoat(Low-E)Tempered over 1/8"4th Surface HP Coating Tempered with Gray EdgeGardMAX Spacer Glazing=Dual Glaze Hardware=Window Opening Control Device,Positive Action Lock Other Options=Fresh Air Flow Vent Screen=Standard with Fiberglass Mesh Ratings=STC:No Rating,OITC:No Rating,PG:LC35 T Clear Opening=W 27"x H 26 3/8"Sq.Ft.4.95 Other Ratings=CPD:MIL-A-154-07520-00001 Viewed From Exterior Customer Approval: Quote Number:SQPATKO02325_1 Print Date:4/29/2022 Page 4 of 6 Une: 8 Location: Auantity: 2 Style Line V250,6110,HV,13/8"Setback,Ext White/Int White,U-Factor:.27,SHGC:.30,VT:.56 $209.10 3/32"SunCoat(Low-E) over 3/32"4th Surface HP Coating $2819 Operating Control Device $23.06 Fresh Air Flow Vent $36.90 Tariff Model=Half Vent Item Total: $1.62 $298.62 Size=RO:48"x 36" Line Total: $597.74 i Net Frame:471/2"x 35 1/2" Handing=XO ' Glass=3/32"SunCoat(Low-E)over 3/32"4th Surface HP Coating with Gray EdgeGardMAX i Spacer !' Glazing=Dual Glaze i Hardware=Window Opening Control Device,Positive Action Lock Other Options=Fresh Air Flow Vent Screen=Standard with Fiberglass Mesh {' Ratings=STC:No Rating,OITC:No Rating,PG:LC30 Clear Opening=W 211/8"x H 33"Sq.Ft.4.84 Other Ratings=CPD:MIL-A-153-07526-00001 Viewed From Exterior Customer Approval: Line: 9 Location: Quantity: 2 Style Line V250,6340,PW,13/8"Setback,Ext White/Int White,U-Factor:.25,SHGC:.33,VT:.63 $83.54 3/32"SunCoat(Low-E) over 3/32"4th Surface HP Coating $9.74 Tariff $1.62 Item Total: $94.90 Model=Picture ' ` Size=RO:24"x 24" Line Total: $189.79 Net Frame:231/2 x 23 1/2 { Glass=3/32"SunCoat(Low-E)over 3/32"4th Surface HP Coating with Gray EdgeGardMAX Spacer ( Glazing=Dual Glaze Ratings=STC:No Rating,OITC:No Rating,PG:CW40 Other Ratings=CPD:MIL-A-178-05512-00001 Viewed From Exterior Customer Approval: Quote Number: SQPATKO02325_1 Print Date:4/29/2022 Page 5 of 6 n PA PARR LUMBER CO-WANKERS CORNER 2351 SW Borland Rd. RR West Linn,OR 97068 Fd L U M B E R 503-638-7575 Submitted By: Material Subtotal: $23,213.73 Accepted By: Grand Total(USD): $23,213.73 Date: - - ---- -- -- ---- ------------ -------- For warranty information please visit www.milgard.com/warranty/ Please note that actual NFRC energy values may vary from those reported in CTB Quote Plus due to variations that may occur during the manufacturing process.In most cases variations will be minimal.Please contact your Milgard location with questions or concerns regarding this potential variation. Painted Vinyl Note:For stucco applications,please follow the Milgard Stucco Tape Guidelines https://www.miii ard.com/sites/default/files/u/u57666/stucco taping guidelines 0920 pdf. Handing is viewed from outside looking in. ADDITIONAL INFORMATION: Quote Number:SQPATK002325-1 Print Date:4/29/2022 Page 6 of 6 ._�W=�I�IU3J1df1 �+ NODORO € ���M �L � �° a 111�i4xx?E!D►/�3 3n x mnam A 'BI 111 �j��N�/1T/ rI WL MS IL.R.Rimy �G ' Q a� — 44 f y: ji Ill's 3W WS(AIS ny- %: kill is y �n �f9h����PY���aT gfig. all 184F X,Mi III b gg - �9'gg�pe R � p9y $Gyp O _. j