Loading...
Report (3) lcoFasten, For InstaLlers. By InstalLers. J COMPLETE RAIL- BASED RACKING SYSTEM INSTALLATION GUIDE CLICK INSTALLATION GUIDE E c o F asten, For Instatters. By Installers. Ak*k Clicking the page name will take you to that page TABLE...OF...CONTENTS.................................................PAGE...01. FEATURES & BENEFITS PAGE 02 .............................................................................................................................. INTRODUCTION PAGE 03 ....................................................................................................................................... .OVERVIEW................................................................................PAGE...04 .C.O.M.P.O.N.E.N.T.S...................................I................................PAGE...0.5. RATINGS.....................................................................................PAGE...06. ARRAY LAYOUT PAG"7 I...................................................................................................................................... .I.N.S.TA.L.LATION.............................................. ....................PAGE...0.8. .G.R.O.U.N.D.I.N.G.........................................................................PAP.E...1.7. ACCESSORIES PAGE 21 ....................................................................................................................................... MODULE...LIST.......................................................................PAGE...27. .C.LAMP..PART..N.U..M.B.E.RS..........................................PAGE...36. REVISION DATE 03/3/32 VERSION:v2.7 INSTALLATION , 4.,TICOFasten-, For Installers. By Installers. CLICKFIT ClickFit conforms to UL 2703 and is one of the fastest installing rail-based systems in the industry. Thanks to its Click-In Rail assembly, the rails can be connected to any of EcoFasten's composition shingle, tile, and metal roof mounts in seconds without the need for fasteners or tools.The ClickFit system is made of robust materials, such as aluminum and coated steel, to ensure corrosion resistance and longevity. ClickFit has been tested in extreme weather conditions including wind, fire, and snow. FEATURES • Tool and fastener free rail attachment r-w • Fully integrated bonding • Click-on Mid & End Clamps • Compatible with a variety of EcoFasten roof attachments PAGE 02 J-1 �1 REVISION DATE:p!/3/23 VEIWON:YL7 Ci INSTALLATION GUIDE EcoFasten,. For Instatters. By InstaLters. INTRODUCTION This manual describes the installation of the ClickFit mounting system for photovoltaic modules on steep-slope roofs. Described within are details for composition shingle and tile, attachments for ClickFit System. Other roof types as well as all other installation manuals can be found for download at www. EcoFastenSolar com GENERAL INSTALLATION CONDITIONS Failure to observe the requirements in this document can lead to the exclusion of all guarantees and product liability. EcoFasten Solar reserves the right to amend this document without prior notice. STABILITY AND CONDITION OF THE ROOF The roof must be in good condition and strong enough to support the weight of the modules, including the additional equipment, wind and snow loads. When in doubt, consult with the engineer of record, and/or the local building inspector. t x� APPLICATION RANGE OF CLICKFIT Refer to Compatibility module list at the end of this document. Please refer to the Ecofasten ClickFit span tables for system structural certification and allowable spans. r WARRANTY Guarantee according to the warranty conditions and general terms and conditions of EcoFasten Solar.These conditions can be found on the website at www. Eco Fasten Solar.com. LIABILITY EcoFasten Solar cannot accept any liability whatsoever for damage or injury caused by not taking adequate safety precautions or(accurately)following the instructions given, or resulting from negligence during the installation of the product and any corresponding accessories specified in this document. ' avenop oAte:e3nnz vertsort its " 1 �r- Eco Fasten, For OVERVIEW The ClickFit mounting system consists of patented adjustable tile hooks and L feet, rails, and the installation materials required for the mounting of photovoltaic modules on composition shingle or tile roofs. For simplicity, tile hooks and L feet will be referred to as"attachments". . ATTACHING TO THE ROOF .. The attachments are fastened to the rafters. Attachments are height-adjustable to level the system on uneven roof surfaces. ATTACHING THE RAIL The rail assembles to the attachments with a click-connector, or Clicker.The rail simply clicks into place without the use of any tools. ATTACHING THE MODULES LILL . . The modules are attached to the rails by means of mid clamps and end clamps. Installer must review module and any 3rd party manufacturer's documentation for compatibility and compliance with warranty terms and conditions. REYWON DAT@09/3/72 VERAON:Y1.! INSTALLATION GUIOE / asten., • SYSTEM COMPONENTS REQUIRED ,r Fr VFW'u CLICKFIT RAIL RAIL SPLICE TILE HOOK le L-FOOT END CAP MID CLAMP END CLAMP SYSTEM COMPONENTS ACCESSORIES AW FRAME MLPE MODULE JUMPER MLPE MOUNT MOUNT Refer to ClickFit Alternate Component Addendum for components not shown , ' REVISION DATE:03/3/2] VERSION:V2.7 � � k A � EcoFasten, • , RATINGS Fire Rating* Class A System Fire Rating Max System Voltage 1500 VDC Max Fuse Rating 40A Certification Conforms to UL STD 2703 Warranty 25 Year Material and Workmanship UL 2703 Markings Product listing label is located on the rail end-caps Roof Pitch 2:12-12:12 UL 2703 Allowable Design Load Rating 10 psf downward,5 psf upward,and 5 psf lateral Max Module Size 25.6 sgft Module Orientation Portrait or Landscape Multiple use Rated Components(Position Independent) Mid Clamp,Frame MLPE Mount and MLPE Mount *Class A System fire rating with Type 1 &2 PV modules.Any module-to-roofap is permitted,with no skin.x itri This applicable with any roof attachment. UL 2703 MARKING EXAMPLE: ESDEC EcoFaste CLICKFIT Intertek MFG ID CODE: Q TORQUE SPECIFICATIONS Component Torque(in-lb) Notes Full Seat.Use visual indicator of the b Lag Screw N/A bonded washer for torquing. lack EPDM ring around the Mid-Clamp 144 End-Clamp 96 Rail Clicker Leveling Bolt 142 Pre-torqued upon delivery.Applies to Tile Hook and L-Foot/Clicker Hook Height Bolt N/A Lightly clamp hook to flush with top of next the row Ground Lug N/A Refer to specific ground lug manufacturer's installation manual MLPE Clip 144 MLPE Mount 144 fi t PAGE • REVISION DATE:03/3/22 VERSION:v2.) VIII INSTALLATION GUIDE '.' coFasten, • .y III • Refer to span tables, local jurisdiction, or engineer of record specifications when determining setbacks from roof edges, attachment spans, etc. • Mark the perimeter and corners of the array on the roof surface. *Add 3/4" to account for the gap between modules in each direction* • Draw or snap chalk lines where the rails will be installed,(refer to module manufacturer specs to determine allowable mounting locations). • Locate rafters within the area of the array. It may be necessary to shift the array East or West on the roof in order to fall within the rail cantilever specs (1/ 3 of span). • Stagger rafters every row if required by the local jurisdiction, engineer of record, or company policy. RlYWON YAT�93/S/I2 YlRSWN:YL7 � INSTALLATION GU ,�,� E c o F a s t - For Installers. By Installers. AOOO Ar' r rt . PRE-INSTALLING RAIL SPLICES 1. Determine the number of rails required per row of modules. 2. Insert a rail splice into one rail. Do not push it past the center bump. 3. Slide the next rail onto the rail splice until the two rail ends meet. 4. Repeat steps 2 and 3 until the desired length is achieved. This is usually easiest to do from the ground. PAGE 08 REVISION DATE:07/3/t2 VERSION:YL7 R EcoFasten INSTALLATION GUIDE For Installers. By Installers. N. INSTALLATION OF FLASHING & L-FOOT • ClickFit for comp shingle roofs uses EcoFasten GF-1 " watertight flashing system. • Other roof types may use different EcoFasten Solar ` attachments, visit ecofastensolar.com to learn about other applications. � Note the orientation of the L foot and Clicker.The two Clicker"arms"should be facing downslope' INSTALLATION STEPS: 1. Locate rafter lines. 2. Drill 1/4" pilot holes at all attachment points and back fill using roof- compatible sealant. 3. Separate shingles where flashing is to be installed. Insert the flashing so the top portion is under the next row of shingles North. Ensure the flashing is pushed to the third-course of shingle to prevent water infiltration through the vertical joints between shingles. 4. Align GF-1 flashing hole with pilot hole. Insert the lag bolt with pre-installed bonded washer through the L foot and EPDM grommet. Tighten the lag bolt until fully seated. The EPDM Ring visual indicator is the most effective way to ensure a watertight seal. PAGE REVISION DATE:03/3/13 YERSiIOp:YLT GUIDEINSTALLATION '.' Osten, For Instatters. By Installers. INSTALLING TILE HOOKS 1. Locate rafters on the roof, mark the tiles to be removed. Hint: In some cases rafter tails' are visible at the eaves of the roof, making it easy to find the rough location of the rafters. In other cases, the fascia board may have nail heads visible where it was attached to the rafters. In the worst-case a row of tiles may need to be moved to determine the rafter locations. 2. Slide the tile at the desired location upward to expose the roof sub surface. If the tile is to be notched,or if using a replacement flashing, remove it entirely. Clean the sub surface with a brush to remove any debris that could affect the sealing. 3. Locate the rafter center and mark it. 4. Place the tile hook with the hook itself in the valley of the next tile below. Drill one 1/4" . %, pilot hole in the rafter center,taking care to keep the hook in the valley of the the below. Backfill this hole with a roof- compatible sealant. For flat tiles, try to avoid ha ok_ land directly under a joint between tiles, this will create a larger gap or more notching than . necessary. a a S. Install one 5/16"x 4"lag screw on the row of holes closest to the tile hook arm. If possible, y r ;.. install the screw in one of the three holes directly next to the arm. If the lag screw must be installed in one of the seven holes furthest from the arm (denoted by the red rectangle below), install three deck screws in the pattern shown by the green circles below. } 6. Adjust the height of the tile hook as necessary using the bolt shown in the fourth image. , 7. Flash the surrounding area and lag screw head with roof-compatible sealant as necessary. Refer to Tile Hook Subflashing Installation guide on the next page. 8. Replace the tile that was moved and/or removed, or install the the replacement flashing. If it is to be notched, mark the tile for notching. Notching can be done with a grinding ,. wheel or by using a chisel. 7 377-7-57 � ♦ �y it'�•` `✓F.d'r 6. r/M� CLICK 0 INSTALLATION GUIDE ;CO>o EcoFasten, For Installers. By Installers. , �IIfWWf�( ; Apply a continuous line of the roofing Lower the sub-flashing over the tile hook base.It may manufacturer's approved sealant on the be necessary to move adjacent tiles to easily lower the underside of the Clickfile hook sub-flashing sub-flashing onto the roof deck. r,U-shape around the raised edges. g , EcoFasten recommends following the TRI guidelines Place the sub-flashing over the base of the tile hook so three-course sealing method.Start the three-course the flashing covers the entire base. sealing method by applying a layer of roofing mastic over the edges of the tile hook sub-flashing. a, Place strips of reinforcing fabric over mastic to cover approximately 2"from the edge of the Apply a final layer of mastic to completely cover sub-flashing in both directions.Place strips on the reinforcing fabric.The flashing is now installed PAGE the side first,then the top edge. and sealed. 11 REVISION DATE 03/3/32 VERSION:v2.7 INSTALLATIONEcoFasten , 'V' Foi Installers. By Instatters. CLICKFIT INSTALLATION USING SIM PLEB LOCK-U® PRE-INSTALLATION: The SimpleBlock-U can be installed on many different standing seam profiles. See SimpleBlock-U Installation Manual for compatible and non-compatible standing seam profiles. Be sure that each standing seam is no thicker than 1/2"in width. INSTALLATION: r;gip OPosition the SimpleBlock assembly on the panel seam. Make sure the block is fully seated on the metal seam. � ... �i 61 - �_ � Torque the 2 preinstalled oval point set screws to � � Nul., 150in-lbs using the included 3/16"hex drive. 2 3 Included with the block, slide the hex holt into.the channel on top of the SimpleBlock-U assembly. Place the ClickFit Universal L-Foot over the hex bolter 3 followed by the serrated flange nut and torque to 150in-lbs. 1"MAX y2'MAX wskz zl �L�_� z 1 �Z._ Z ---r,MAX Z �^t�f� 4 IL REVISION DATE 03/3/!2 VERSION:v2.7 INSTALLATION GUIOE 40,'o-' INSTALLING THE RAIL 1. Place the rail in the Clickers. 2. Ensure the rails extend a minimum V of 2" past the last attachments in each row. 3. Push the rail into each L-foot; an audible click should be he when the rail is fully seated. Verify the rail is sitting flush with both ledges. If attachments are extremely misaligned it may be necessary to loosen the leveling ' bolt and adjust the height of the L-foot. Tighten the clamping bolt WMJ to 144 in-lbs. 4. Level the rail if necessary by loosening the bolt attaching the "� Clicker to the L-foot or tile hook. REVISION DATk••/3/22 VERSION:v27 INSTALLATION GUIDE EcoF as ten, Foi InstaRers. By Installers. MODULE INSTALLATION INSTALL THE END CLAMPS ON EACH RAIL ON WHATEVER END YOU ARE STARTING WITH 'a Snap the end clamp onto the rail. 'b Slide the end cap onto the rail. Turn the leg of the end clamp around the cap. O Q PLACE MODULE Place the module on the rail, ensuring the module junction box is up-slope.* 2 Q ALIGN AND TIGHTEN Slide the module to the end clamp and align it with the array corners.Tighten the end clamp to 96 in-Ib 143PAGE REVISION DATE OS/7/S2 -VERf10N:viz INSTALLATION GUIDE -UtIcoFasten, Foi Instal[ers. By Installers. INSTALLING ADDITIONAL MODULES O CLICK IT ON Click a mid clamp onto each rail. a Q SLIDE IT UP Slide the mid clamps until they are flush with the side of the existing module. _ . . O PLACE AND TIGHTEN Place and slide the next module firmly against the mid clamps. Align the �r bottom edges of the modules. Tighten . mid clamps to 144 in-Ib. QA,. 3 REVISION DATE:03/3/72 VERSION:Y2.7 INSTALLATION D C."> For Instalters. By Installers. INSTALLING END CLAMPS AT THE END OF A ROW 1. Install the last mid clamps in the row. 2. Measure the rails from the last mid clamp to the module width plus 1". 3. Cut the rails at this mark. There is some adjustment in the end cap/clamp so it does not need to be a perfect cut. 4. Install end clamps and end caps, tighten to 96 in-lb ° ALTERNATIVE METHOD: ' 1. Install the last..module.in..the_row,tighten the mid clamps. _- XR. 2. Using a circular saw with a metal blade, or carefully with a reciprocating saw, cut the rail kb;' m approximately 1"past the edge of the last module. 3. Install end clamps and end caps,tighten to 96 in-Ib Replace the tile that was moved and/or removed, or install the the replacement flashing. If it is to be notched, mark the tile for notching. Notching can be done with a grinding wheel or by using a chisel. �� r , .. AM A90111k MW MPM Y f.. 16 RMSION OATk 07/7/12 YlRSION:v27 INSTALLATION GUIDE '�> " Foi Installers. By Instatters. BONDING AND GROUNDING BONDING PATHS Bonding paths are carried throughout the array in a variety of ways. They are carried module- to-module and module-to-rail through mid clamps, carried at rail-to-rail connections through the bondingjumpers, and carried row-to-row using bondingjumpers either module-to-module on the module frame or rail-to-rail on the ends of the rails. MID CLAMP 2 mid clamps bonding pairs of modules GROUNDING LUG .,. 1 ground lug per continuous array MIPMMMMMMM 1 OK s . i f RAIL SPLICE 1 splice bonding MODULE JUMPER adjacent pair of rails 1 module jumper bonding module to module and row to row REVISION DATE OS/0f�2 VERSION:VL7 !C INSTALLATION .•' EcoFasten; • GROUNDING NECESSARY COMPONENTS One of the following grounding lugs(or any UL 2703 Compliant ground Lug): • BurndyCL50-lTN Ground Lug(UL 2703 - E3514343/ UL 467-E9999) • ILSCO SGB-4 Ground Lug (UL 2703 - E354420/UL 467- E34440) • ILSCO GBL-4DBT(UL 2703 - E354420/ UL467 - E34440) • ILSCO GBL-4DBTH (UL 2703 - E354420/ UL 467- E34440) • ILSCO GBL-4SS (UL 2703 - E354420 J UL 467- E34440) go � *Equipment grounding wire should be sized in accordance with the National Electrical Code,NFPA70 PAGE and a minimum of 1/4"clearance is required between bare copper wires and aluminum components. • 7 CLICK 0 INSTALLATION GUIDE oOa EcoFastenx For Installers. By Installers. i \ V Lower the MLPE Mount to the rail Tilt and hook the mount around the top"dog ear"of the rail ■�1 ■1111 A Set the MLPE Mount flush with the top of the rail Slide the microinverter flange between the MLPE Mount and the serrated bolt flange Tighten the bolt to 144 in-lbs Repeat this process for all other microinverter and/or optimizer installations PAGE 19 CLICK aOD EINSTALLATION GUIDE ora coFasten For Installers. By Installers. With the ClickFit Rail in place and the Wire Clip in hand, place the wire end on either side of the rail. With the wire end touching the bottom lip of the rail, roll and click- in the Wire Clip to the opposite end of the rail. You will hear an audible click when the Wire Clip is set in place. °F I PAGE 20 REVISION DATE:03/3/22 VERSfON:v2.7 l INSTALLATION GUIDE EcoFasten, Foi Installers. By Instatters. FRAME MLPE MOUNT k; 1� INSTALLING THE FRAME MLPE MOUNT ACCESSORY: • Install the Frame MLPE Mount • Slide the Frame MLPE Mount onto the lip of the micro-inverter/power optimizer. • Slide the micro-inverter/power optimizer into the opposite lip of the module frame. • Tighten the bolt to 144 in-Ib to clamp the Frame MLPE Mount to the module-frafne-and the z� v micro-inverter/power optimizer to the Frame MLPE Mount. • Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power optimizer flange is tight against the clip flange to avoid rotation during tightening. FRAME MLPE MOUNT AND MLPE MOUNT ARE COMPATIBLE WITH: • EN PHASE: M250-72, 250-60, M215-60, C250-72, 5230, S280, IQ 6, IQ 6+, IQ7, IQ 7A, IQ 7+, IQ7 PD, IQ 7X, Q Aggregator; IQ8-60, IQ8PLUS-72, IQ8A-72, IQ81-1-208-72, IQ81-1-240-72, IQ8M-72, may be followed by-2-US '° ' • SOLAREDGE: M1600, P300, P320, P340, P370, P400, P401, P405, P485, P505, P600, P700, P730, P800p, P800s, P801, P850, P860, P950, P960, P1100, P1101, 5440, S500 • SEE PAGE 26 FOR COMPATIBLE MODULE LIST PAGE r REVWON DATE OS/3/t2 VERSION:v27 INSTALLATION / E CIO asten, • MODULE MAINTENANCE AND SERVICING During servicing or maintenance, module removal may disrupt the bonding path and could introduce the risk of electric shock. If module removal is required for servicing,then a Module jumper shall be installed to the adjacent modules to maintain the bond path. Modules should only be removed by qualified persons in compliance with the instructions in this manual. c Bond Path Grounding Lug Equipment Grounding .: Conductor(EGC) generally to earth ir 11111111"91111111 ground ® Brackets/Mid-Clamps UJ A� M196 -1 Module jumper Alm ma 7�: REVISION DATA DS/3rl2 VERSION:V27 y INSTALLATION GUIDE ,.,' EcoFasten. For Installers. By Installers. JUNCTION BOX INSTALLATION JUNCTION BOX PREP Prior to installation, use step drill bit to place pass through holes for conduits or water-tight connectors. Drill bit starter locations are provided on the sides and front of enclosure. Do not install conduit facing up roof. 1.� RAIL INSTALLATION Use rail-specific MI_PE mounting hardware to attach Rail Hangers to rail. Ensure junction box is pushed as close to the rail as possible.Torque to 80-in Ibs(1/2"or 7/16" socket),do not overtighten. *If installing in areas with ground snow loads greater than 40 psf,instalijunction Box under module directly next to module frame edge. RFYISION DATE:O3/3/12 YlRSION:v17 � 1. 3 , `a wmLqr INSTALLATION GUIDE V Foi- Instalters. By Installers. '46 JUNCTION BOX INSTALLATION DECK SCREWS WITH SEALING WASHERS(2X) DECK MOUNTED INSTALLATION Align sealing oval of box to align with mating feature on flashing.An EPDM foam gasket is pre-installed to the underside of the junction box to seal the flashing to the box without the need for additional sealant. Secure with supplied#12 x 1- "deck screws(2x) until the junction box is pulled tight to the flashing. Do not over-tighten screws to avoid stripping screws in OSB. *If installing pass through fittings,ensure that theJunction Box and roof deck are both properly prepared.Complete installation t ` process before attaching theJunction box to the deck. FINALIZING INSTALLATION Install wiring, conduit and fittings per NEC requirements and following local AHJ guidance. Using Philips Head Driver tighten the bolt. For additional details refer to the full Junction Box Installation Manual. PAGE 24 M,r, REVISION DATE:03B/32 VERSION:v27 CLICK INSTALLATION GUIDE t' .74> For Instatters. By Instatters. SKIRT INSTALLATION (OPTIONAL) The skirt is designed to give the rows of the array facing the eave of the roof a uniform *° appearance.The installation consists of three basic components listed below. f SKIRT& END CAP SKIRT CLAMP 1. Once the first row of modules is installed (or after the array is complete ), locate the correct length and number of skirts for the array. 2. Locate the correct amount of skirt clamps for the array. 80"skirts are preferred when applicable.The general rule when using 80"skirts is the number of modules plus one for the � �� end of the array. When using 65"skirts, the rule changes to 2 skirt clamps per module.The general rule is number of modules plus one for the end of the array. If you have ten modules you will need eleven skirt clamps. In the case of heavy snow loads or other circumstances call EcoFasten Solar for additional instructions. 3. Working with a helper, align the end of the skirt with one edge of the array, drop the first skirt clamp onto the module and skirt, ensure all flat faces are parallel and fully engaged with eachk other. Skirt clamps must be installed within 10 inches from the end of the Skirt. Ensure the clamp is engaging either the top of the skirt or the step depending on the module size. Tighten _ bolt to 12 ft-Ib. 4. There should be enough play in the assembly to drop the next skirt clamp onto the next module at roughly the same location relative to the clamp on the last module. Ensure all �f faces are parallel and fully engaged with each other. Slide next skirt over the skirt end cap or coupling of the first skirt. Tighten bolt to 12 ft-Ib. 5. Repeat steps 3 and 4 until the end of the array is reached. Install a skirt clamp within 10 '$ inches from the end of the array. Cut the skirt flush with the end of the array as necessary.An additional skirt clamp may be necessary to hold a short piece of skirt at the end of the array. ; 6. Once the last skirt is cut and clamped in place, install an end cap in the end of the last skirt. To '� Ty ensure the end cap stays in place through various weather conditions, it is acceptable to install a small amount of roof sealant onto the edge of the end cap that will contact the inside face of the skirt. Replace the the that was moved and/or removed, or install the tile replacement flashing. If it is to be notched, mark the the for notching. Notching can be done with a grinding wheel or by using a chisel. REVISION DATE:03/3/32 VERSION:v2.7 INSTALLATION GUIDE <10t- EcoF a sten, For InstaRers. By Instal.l.ers. Install first skirt clamp within 10 inches from the end of the array with 80"skirts, the second clamp location will be similar to the first clamp but installed on the second module. Continue to the end of the array. f . Install last skirt clamp within 1 rheVrarn the- end of the array prior to cutting. tr,k;,, a g , k Yib< \ o. Install end cap on the last module.Adding a ,,- small amount of sealant is optional. x g� �h t4yti THINGS TO CONSIDER PRIOR TO INSTALLING THE SKIRT ARE: • Potential snow drifting in the area the skirt is to be installed. If the snow load is greater than 20psf in your region two skirt clamps are required per module and skirt coupler must be used. Contact EcoFasten for information on the skirt coupler. • There are three options for skirts:A, B and C.The A& B skirts can be identified by looking at the inner channel, if it's ribbed then it is a B skirt and will use 32mm (inner channel) and 38mm utilizing the top of the skirt.A skirts will have a smooth inner channel and use PAGE 35mm (inner channel) and 40mm utilizing the top of the skirt. C skirts will only use 30mm skirts and do NOT have an inner channel. 26 REVISION DATE:09/3/32 VERSION:YL7 � INSTALLATION GUIDE .. EcoFasten- 4 For Instalters. By InstaLters. 'N UL 2703 CERTIFIED MODULES This racking system may be used to ground and/or mount a PV module complying with UL 1703 or UL 61730 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. APPROVED -MANUFACTURER OF UL 2703 Adani modules with 35 and 40mm frames Adani ASX-Y-ZZ-xxx Where"X"can be B, M or P, "Y"can be 6 or 7,and"ZZ"can be blank, PERC, B-PERC, or AB-PERC Aionrise modules with 35 and 40mm frames Aionrise AIONyyG1-xxx Where"y('can be 60 or 72 Amerisolar modules with 35,40 and 50 mm frames AS-bYxxxZ Amerisolar Where"b"can be 5 or 6;"Y"can be M, P, M27, P27, M30, or P30; and Z can be blank,W or WB Aptos modules with 35 and 40 mm frames Aptos Solar DNA-yy-zzaa-xxx Where"yy"can be 120 or 144;"zz"can be MF or BF; and"aa"can be 23 or 26 Astronergy modules with 30,35,40, and 45 mm frames i aaSMbbyyC/zz-xxx Astronergy Solar Where"aa"can be CH or A;"bb"can be 60, 66, or 72;"YY'can be blank, 10 or 12;"C"can M, P, M(BL), M-HC, M(BL)-HC, P-HC, M(DG), or M(DGT); and "zz"can be blank, HV, F-B, or F-BH ASUN modules with 35 and 40 mm frames ASUN ASUN-xxx-YYZZ-aa Where"YY"can be 60 or 72;"ZZ"can be M,or MH5; and"aa"can be blank or BB Auxin modules with 40 mm frames Auxin AXN6y6zAxxxB Where"y"can be M or P;"z" can be 08, 09, 10, 11, or 12; and"A"can be F, M or T; and"B"can be blank,A, B or C PAGE REVISION DAtE:03/3/22 VERSION:V2.I SII INSTALLATION GUIDE i',D',' EcoFasten, For Insta[teis. By Installers. MANUFACTURER LIST OF • MODULES Axitec Modules with 30, 35 and 40 mm frames Axitec AC-xxxY/aaZZb Where"Y"can be M, P or MH;"aa"can be blank, 125-or 156-;"ZZ"can be 54, 60, 72, 108, 120, or 144; "b"can be S, X,V,V13,XV, or MX Boviet modules with 35 and 40mm frames Boviet BVM66aaYY-xxxBcc Where"aa"can be 9, 10 or 12;"YY" is M, or P; and"B"can be blank, L or S; and"cc"can be blank, H, H-BF, H-HC, HC-BF or H-HC-BF BYD modules with 35 mm frames BYD BYDxxxAY-ZZ Where"A"can be M6, P6, MH or PH; "Y"can be C or K; and"ZZ"can be 30 or 36 Canadian Solar modules with 30,35 and 40 mm frames Canadian Solar CSbY-xxxZ Where"b"can be 1, 3 or 6;"Y"can be H, K, L, N, P, U,V,W,XorY; and "Z" can be M, P, MS, PX, M-SD, P-AG, P-SD, MB-AG, PB-AG, MS-AG, or MS-SD CertainTeed modules with 35 and 40mm frames C CertainTeed TxxxYZZ-AA Where"Y"can be M, P, or HC;"ZZ"can be 00, 01, 10, or 11; and"AA"can be 01, 02, 03, 04 or 06 Csun modules with 35 and 40 mm frames CSUN YYxxx-zzAbb Where"YY"is CSUN or SST;"zz"is blank, 60, or 72; and"A"is blank, P or M or MM;"bb"is blank, BB, 5613, BW, or ROOF Dehui modules with 35 and 40mm frames Dehui DH-MYYYZ-xxx Where"YYY"can be 760, 772, 860, 872; and"Z"can be B or W Ecosolargy modules with 35,40, and 50 mm frames Ecosolargy ECOxxxYzzA-bbD Where"Y"can be A, H, S, or T;"zz"can be 125 or 156;"A"can be M or P;"bb" can be 60 or 72; and"D"can be blank or B ET Solar modules with 35,40,and 50 mm frames ET-YZZZxxxAA ET Solar Where"Y"can be P, L, or M; "ZZZ"can be 660, 660131-1, 672, 672BH, 754BH or 7666H; and "AA"can be TB,TW,WB,WW, B13,WBG, WWG,WBAC,WBCO, WWCO,WWBCO or BBAC REVISION DATE:03/3/22 VERSION:v2.7 °' CLICK INSTALLATION ,. EcoFasten For Installers. By Installers. MANUFACTURER LIST OF UL t APPROVED . • • Flex modules with 35,40, and 50 mm frames Flex FXS-xxxYY-ZZ; Where"YY"can be BB or BC; and"ZZ"can be MAA1 B, MAA1 W, MAB1 W, SAA1 B, SAA1 W, SAC1 B, SAC1 W, SAD1 W, SBA1 B, SBA1 W, SBC1 B, or SBC1 W GCL modules with 35 mm and 40 mm frames GCL GCL-ab/YY xxx Where"a"can be M or P;"b"can be 3 or 6; and"YY"can be 60, 72, 72H, or 72DH Gigawatt modules with 40 mm frames GigaWatt Solar GWxxxYY Where"YY"can be either PB or MB Hansol modules with 35 and 40 frames \�1 Hansol HSxxxYY-zz Where"YY"can be PB, PD, PE,TB,TD, UB, UD, or UE; and"zz"can be AH2, AN1,AN3,AN4, HH2, HV1, orJH2 Hanwha Solar modules with 40,45, and 50 mm frames Hanwha Solar HSLaaP6-YY-1-xxxZ Where"aa"can be either 60 or 72;"YY"can be PA or PB; and "Z"can be blank or B Hanwha Q CELLS Modules with 32, 35,40, and 42mm frames > - aaYY-ZZ-xxx where"aa"can be Q. or B.;"YY"can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, PLUS DUO or PEAK DUO; and"ZZ"can be G3, G3.1, G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/TAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/ SC, G4.1/TAA, G4.1/MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK Hanwha Q CELLS G4.1/SC, EC-G4.4, G5, G5/SC, G5/TS, BLK-G5, BLK-G5/SC, BLK-G5/TS, L-G5, L-G5.1, L-G5.2, L-G5.2/1-1, L-G5.3, G6, G6/SC, G6/TS, G6+, BLK-G6, L-G6, L-G6.1, L-G6.2, L-G6.3, G7, BLK-G6+, BLK-G6+/AC, BLK-G6+/HL, BLK-G6+/SC, , w� BLK-G6/TS,G6+/TS, BLK-G6+/TS, BLK-G7, G7.2, G8, BLK-G8, G8+, BLK-G8+ L-G7, L-G7.1, L-G7.2, L-G7.3, L-G8, L-G8.1, L-G8.2, L-G8.3, L-G8.3/BFF, ML-G9, BLK ML-G9, ML-G9+, BLK ML-G9+, BLK-G10+, BLK-G10+/AC, ML-G10, BLK ML-G10, ML-G10+, BLK ML-G10+, ML-G10.a, BILK ML-G10.a, ML-G10.a+, BLK ML-G10.a+,XL-G9, XL-G9.2,XL-G9.3,XL-G10.2,XL-G10.3,XL-G10.c or XL- j G10.d ';`� REVWON DATE:03/S!=2 VERSION:v27 � i i INSTALLATION '�' EcoFasten; j- MANUFACTURER LIST OF 13 APPROVED MODULES Heliene modules with 40 mm frames YYZZxxxA Heliene Where"W"can be 36, 60, 72,96, 120 or 144;"ZZ"can be HC, M, P, or MBLK; and"A"can be blank, HomePV, or Bifacial HT-SAAE modules with 35 and 40 mm frames HT-SAAE HTyy-aaaZ-xxx Where"yy"can be 60, 66 or 72;"aaa"can be 18, 156 or 166; "Z"can be M, P, M-C, P-C, M(S), M(VS), M(V), P(V), M(V)-C, P(V)-C, or X Hyundai modules with 33, 35,40 and 50 mm frames Hyundai H iY-SxxxZZ Where"Y"can be A, D or S;"S"can be M or S; and"ZZ"can be HG, HI, KI, MI, MF, MG, PI, RI, RG, RG(BF), RG(BK), SG,TI or TG Itek Modules with 40 and 50 mm frames "`` MPF Itek IT-xxx-W Lill Where"YY"can be blank, HE, or SE, or SE72 JA Solar modules with 30, 35,40 and 45 mm frames JAyyzz-bbww-xxx/aa Where"yy"can be M, P, M6 or P6;"zz"can be blank,(K), (L), (R), (V), (BK), (FA), )A Solar (TG),(FA)(R),(L)(BK), (L)(TG), (R)(BK), (R)(TG), (V)(BK),(BK)(TG), or(L)(BK)(TG); "bb"can be 48, 54, 60, 66, 72 or 78; "ww"can be D09,501, 502,503, 506, 509, 510, 512, 517, 520, S30 or 531; and"aa"can be BP, MR, SI, SC, PR,3BB, 11 llll�� 11111F 468,4BB/RE, 51313 Jinko modules with 35 and 40 mm frames JKMYxxxZZ-aa Where"Y"can either be blank or S; "ZZ"can be M, P, or PP; and "aa"can be )inko blank, 60, 60B, 60H, 60L, 60BL, 60HL, 60H6, 60HBL, 6HBL-EP,60-J4, 6013-J4, 606-EP, 60(Plus), 60-V, 60-MX, 6RL3, 6RL3-B, 6TL3-B, 7RL3-V, 7RL3-TV, 72, 72B, 72-J4, 72B J4, 72(Plus),724, 72H-V,72L-V, 72HL-V, 72-MX, 72H-BDVP, 72HL-TV, or 72HL-V-MX3 Kyocera Modules with 46mm frames KYxxxZZ-AA Kyocera Where"Y"can be D or U;"ZZ"can be blank, GX,or SX;and "AA"can be LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LFB2, LP132, 3AC,3BC,3FC,4AC, 4BC,4FC, 4UC, SAC, 56C, SFC, SUC, 6BC, 6FC, 8BC, 6MCA, or 6MPA LG modules with 35,40,and 46 mm frames `G LGxxxYaZ-bb Where'Y"can be A, E, M, N,Q,S;"a"can be A, 1,2or3;"Z"can be C, K,T,or W; PAGE and"bb"can be A3,A5,A6,133,136,E6,E6.AW5,G3,G4,J5, K4,L5,N5,V5,V6 30 REVISION DATE:03/3/22 VERSION:v2.7 I GUIDEEcoFasten, INSTALLATION '.' • MANUFACTURER LIST O2703 F APPROVED • Longi modules with 30,35 and 40 mm frames Longi LRa-YYZZ-xxxM Where"a"can be 4 or 6;'W"can be blank, 60, 66 or 72; and "ZZ"can be blank, BK, BP, HV, PB, PE, PH, HBD, HIB, HIH, HPB, HPH, or HIBD Mission Solar modules with 33, 35 and 40 mm frames YYYbb-xxxZZaa Mission Solar Where"YYY"can be MSE or TXS;"bb"can be blank, 6 or 60A;"ZZ"can be blank, MM, SE, SO, SQ, SR, SX,TS, 120 or 144; and"aa"can be blank, BB, BW, 1J,4J,4S, 5K, 5R, 5T, 60, 6J, 6S, 6W, 6Z, 8K, 8T, or 9S Mitsubishi modules with 46 mm frames Mitsubishi PV-MYYxxxZZ Where"YY"can be LE or JE; and"ZZ"can be either HD, HD2, or FB Motech IM and XS series modules with 40,45, and 50 mm frames Next Energy Alliance modules with 35 and 40mm frames Cn Next Energy NEA-xxxZZ yy Alliance where"yy"can be blank or US;"ZZ"can be M, MB or M-60 Uj i Neo Solar Power modules with 35 mm frames f Neo Solar Power D6YxxxZZaa mi Where"Y"can be M or P; "ZZ"can be 133A, B4A, BA, E4A, H3A, H4A; and"aa" can be blank,(TF), ME or ME (TF) Panasonic modules with 35 and 40 mm frames Panasonic (HIT) VBHNxxxYYzzA Where"YY"can be either KA, RA, SA or ZA;"zz"can be either 01, 02, 03, 04, C3 06,06B, 11, 11B, 15, 15B, 16, 16B, 17, or18; and"A"can be blank E, GorN Panasonic Panasonic modules with 30 mm frames (EverVolt) EVPVxxxA _ Where"A"can be blank or H, K or PK Peimar modules with 40 mm frames SbxxxYzz Peimar ' Where"b"can be G, M or P;"Y"can be M or P; and"zz"can be blank, (BF), or (FB) I Philadelphia modules with 35 and 40 mm frames PS-YzzAA-xxx Philadelphia Solar Where"Y"can be M or P; "zz"can be 60, 72 or 144; and "AA"can be blank, (BF),(HC)or(HCBF) k q PAGE31 C Y REVISION DATE:03/3/72 VERSION:v2.7 INSTALLATION GUIDE . t:. EcoFasten I For Instattei s. By InstalLers. MANUFACTURER LIST OF • MODULES Phono Solar modules with 35,40, and 45 mm frames Phono Solar PSxxxY-ZZ/A Where"Y"can be M, M1, MH, M1 H, M4, M41-1, or P; "ZZ"can be 20 or 24; and"A"can be F,T, U, UH, or TH i Recom modules with 35 and 40 mm frames I Recom RCM-xxx-6yy Where"yy"can be MA, MB, ME or MF REC modules with 30, 38 and 45 mm frames REC Solar RECxxxYYZZ Where"YY"can be AA, M, NP, NP2, PE, PE72,TP,TP2,TP2M,TP2SM,TP2S, TP3M or TP4; and"ZZ"can be blank, Black, BLK, BLK2, SLV, 72 or Pure ReneSola modules with 35, 40 and 50 mm frames AAxxxY-ZZ Renesola Where"AA"can be SPM(SLP)or JC;"Y"can be blank, F, M or S; and"ZZ" i can be blank,Ab,Ab-b,Abh,Abh-b,Abv,Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, Db-b, or 24/Bb Renogy Modules with 40 and 50 mm frames Renogy RNG-xxxY Where"xxx"is the module power rating; and"Y"can be D or P Risen Modules with 35 and 40 mm frames Risen RSMyy-6-xxxZZ Where"yy'can be 60, 72, 120, 132 or 144; and"ZZ"can be M or P S-Ener modules with 35 and nd 40mm frames SABB-CCYYY-xxxZ S-Energy Where"A"can be C, L or N;"BB"can be blank,20,40 or 45;"CC"can be blank, 60 or 72;"YYY" can be blank, MAE, MAI, MBE, MBI, MCE or MCI; and "Z"can be V, M-10, P-10 or P-15 SEG Solar modules with 35 and 40 mm frames SEG-aYY-xxx-ZZ SEG Solar Where"a"can be blank, 6 or B;"YY"can be blank, MA, MB, PA, or PB; and "ZZ"can be blank, BB, BG, BW, HV,WB, WW, BMB, BMA-HV, BMA-TB, BMB- HV, BMB-TB, BMD-HV Seraphim modules with 35,40 and 50 mm frames Seraphim USA SRP-xxx-YYY-ZZ Where"xxx"is the module power rating; and "YYY"can be 6MA, 6MB, 6PA, v , = 6PB, BMD, 6QA-XX-XX, and 6QB-XX-XX; ZZ is blank, BB or HV PAGE REVISION DATE:03/3/32 VERSION:v2.7♦., INSTALLATION GUIDE EcoFosten, • MANUFACTURER LIST OF APPROVED MODULES 14 Sharp modules with 35 and 40 mm frames Sharp NUYYxxx Where"YY"can be SA or SC Silfab Modules with 35 and 38 mm frames SYY-Z-xxxAb Silfab Where"YY"can be IL, SA, LA, SG or LG;"Z"can be blank, M, P, or X; "A"can be blank, B, H, M, N; and"b"can be A, C, G, K, L, N,T, U or X Solaria modules with 35 and 40 mm frames Solaria PowerXT-xxxY-ZZ Where"Y"can be R or C; and"ZZ"can be AC, BD, BX, BY, PD, PL, PM, PM-AC, PX, PZ,WX or WZ Solarcity modules with 40 mm frames `�• Solarcity (Tesla) scxxxYY -- - Where"YY"can be blank, B1 or B2 SolarTech modules with 40 and 42 mm frames SolarTech AAA-xxxYY Uj Where"AAA"can be PERCB-B, PERCB-W, HJTB-B, HJTB-W or STU;"YY"can be blank, PERC or HJT =j SolarWorld Sunmodule Plus, Protect, Bisun,XL, Bisun XL, may be followed by mono, poly, duo, black, bk, or clear; modules with 31,33 or 46 mm @=I SolarWorld AG frames -.- SW-xxx SolarWorld Sunmodule Plus, Protect, Bisun,XL, Bisun XL, may be followed SolarWorld by mono, poly, duo, black, bk, or clear; modules with 33 mm frames Americas SWA-xxx C3 Sonali Sonali Modules with 40 mm frames SSxxx Stion Stion Thin film modules with 35 mm frames STO-xxx or STO-xxxA SunEdison Modules with 35, 40&50 mm frames SE-YxxxZABCDE SunEdison Where"Y"can be B, F, H, P, R, or Z;"Z"can be 0 or 4;"A"can be B, C, D, E, H, I,J, K, L, M, orN ;"B"can beBorW; "C"can beAorC;"D"can be 3, 7, 8, or 9; and"E"can be 0, 1 or 2 Suniva modules with 35, 38, 40,46, and 50 mm frames OPTxxx-AA-B-YYY-Z Suniva MVXxxx-AA-B-YYY-Z PAGE Where"AV is either 60 or 72;"B"is either 4 or 5; "YYY"is either 100,101,700,1 B0, or 1 B1; and"Z"is blank or B 33 REVISION DATE:03/3/22 VERSION:v2.7 INSTALLATION '.' co asten, • MANUFACTURER LIST OF UL 2703 APPROVED MODULES Sunpower standard(G3 or G4)or InvisiMount(G5)35,40 and 46 mm frames Sunpower SPR-Zb-xxx-YY Where"Z"is either A, E, P, M or X;"b"can be blank, 17, 18, 19, 20, 21, or 22; \ and"YY"can be blank, BLK, COM, C-AC, D-AC, E-AC, BLK-E-AC, G-AC, BLK-C- AC, or BLK-D-AC Sunspark modules with 40 mm frames Sunspark SYY-xxxZ-A Where"YY"can be MX or ST; and"Z"can be M, MB, M3, M313, P or W; and "A"can be 60 or 72 Suntech Modules with 35,40 and 50mm frames STPxxxy-zz/aa �►\ Suntech Where"y"is blank or S; and"z"can be 20, 24,A60 or A72U; and"aa"can be Vd,Vern,Vfw,Vfh,Wdb,Wde,Wd, or Wfhb Talesun modules with 35 and 40mm frames TP6yZZaaxxx-b Uj Talesun Where"y"can be blank, F, H, or L;"ZZ"can be 60 or 72;"aa"can be M, M(H), or P; and"b"can be blank, B,T, or(H) Tesla modules with 40 mm frames Tesla TxxxY Where"Y"can be H or S Trina Modules with 30, 35,40 and 46mm frames TSM-xxxYYZZ Where"YY"can be DD05, DD06, DD14, DE09, DE14, DE06X, DE15, DE15V, Trina DEG 15, PA05, PC05, PD05, PD06, PA14, PC 14, PD14, PE14, or PE15; and"ZZ" can be blank,(II), .05, .05(ll), .08, .10, .18, .08D, .18D,0.82, .002, .00S, 05S, 08S,A,A.05,A.08,A.10,A.18,A(II),A.05(II),A.08(II),A.082(II),A.10(II),A.18(II), H, H(II), H.05(II), H.08(II), HC.20(II), HC.20(11), M, M(II), M.05(II), MC.20(II) URE modules with 35 mm frames URE DyZxxxaa Where"D"can be D or F,"y"can be A, 6 or 7; "Z"can be K or M; and"aa"can be H3A, H4A, H8A, E7G-BB, E8G or E8G-BB Vikram solar modules with 40 mm frames Vikram VSyy.ZZ.AAA.bb Where"yy"can be M, P, MBB, MH, MS, MHBB, or PBB;"ZZ"can be 60 or 72; "AAA" is the module power rating; and"bb"can be 03, 04 or 05 i REVISION DATE:03/3/22 VERSION:v2.7 INSTALLATION , .. Eco Fasten 0' APPROVEDFoi Installeis. By Installers. MANUFACTURER LIST OF UL 2703 • VSUN modules with 30, 35 and 40 mm frames VSUN VSUNxxx-YYz-aa + Where"YY"can be 60, 72, 108, 120, or 144;"z"can be M, P, MH, PH, or BMH; ' and"aa"can be blank, BB or BW Waaree modules with 40mm frames N Waaree WSyy-xxx where"yy'can be blank or M Winaico modules with 35 and 40 mm frames Winaico Wsy-xxxza Where")('can be either P or T;"Z"can be either M, P, or MX; and"a"can be blank or 6 Yingli modules with 35 and 40 mm frames Yingli YLxxxZ-yy Where"Z"can be D or P;"yy"can be 29b, 30b,34d, 35b, 36b or 40d ZN Shine modules with 35mm frames ZN Shine ZXMY-AAA-xxx/M LLJ Where"Y"can be 6 or 7,"AAA"can be 72, NH120, NH144 or NHDB144 Wmi C3 MPMOMMM PAGE . REVISION DATE 03/3/32 VERSION:v2.7 1 A EcoFasten, INSTALLATION GUIDE For Instakeis. By Installers. CLAMP PART NUMBERS END CLAMPS Frame Thickness Article Number 30 m m 2099016 32 mm 2099017 Am Amok 35 mm 2099018 38 mm 2099019 45 mm 2099021 NII MID CLAMPS Frame Thickness Article Number 30-40 mm 2099022 40-50 mm 2099023 INSTALLER RESPONSIBILITIES Periodic re-inspection of components shall be performed to verify that there is no corrosion detrimental to system strength and electrical conductivity, no loose bolts,and/or others -F = variables that could compromise array safety.Any corroded or damaged components shall be 0" � immediately replaced. PAGE 36