Loading...
Report (2) RECEIVED AUG 9 2022SILFAB PRIME •• • • . . s CITY OF TIGARD S I L FQ B BUILDING DIVISION 5 0 L A R'" SIL-380 HC g •; RELIABLE ENERGY. PROUD DIRECT FROM THE SOURCE . PARTNER OF Introducing Silfabl Prime. Designed to outperform. i Dependable, durable, high-performance solar panels engineered for North American homeowners. SILFABSOLAR.COM C - % 1 EC PA5 Fraunhofer c H u e E3 ❑ �_•Intertek Intertek ISE *Chubb provides error and omission insurance to Silfab Solar Inc. LLECTRICAL SPECIFICATIONS 380 Test Conditions STC NOCT Module Power(Pmax) Wp 380 284 Maximum power voltage(Vpmax) V 35.32 SII 3 Maximum power current(Ipmax) A 10.77 32.8 2.8 8.64 Open circuit voltage(Voc) I V 42.17 39.55 Short circuit current(Isc) A 11.36 I 9.16 Module efficiency n/" 20.8% 19.4% Maximum system voltage(VDC) V 1000 Series fuse rating A 20 Power Tolerance Wp ±3% Measurement conditions:STC 1000 W/ma•AM 1.5•Temperature 25'C•NOCT 800 W/m'•AM 1.5•Measurement uncertainty<_3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by+5%and power by±3%. MECHANICAL PROPERTIES/COMPONENTS METRIC IMPERIAL Module weight 19.5kg±0.2kg 43lbs±0.41bs Dimensions(H x L x D) 1762 mm x 1037 mm x 35 mm 69.4 in x 40.8 in x 1.37 in Maximum surface load(wind/snow)" 5400 Pa rear load/5400 Pa front load 112.8 Ib/ft'rear load/112.8 Ib/ft'front load Hail impact resistance a 25 mm at 83 km/h o 1 in at 51.6 mph cells i120 Half cells-Si mono PERC I 120 Half cells-Si mono PERC 9 busbar-83 x 166 mm I 9 busbar-3.26 x 6.53 in Glass 3.2 mm high transmittance,tempered, ! 0.126 in high transmittance,tempered, DSM amireflective coating ( DSM antireflective coating Cables and connectors(referto installation manual) 1350 mm,o 5.7 mm,MC4 from Staubli 53.15 in,o 0.22 in(12AWG),MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, fluorine-free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IEC 62790 Certified,IP68 rated TEMPERATURE RATINGS WARRANTIES Temperature Coefficient Isc +0.064%/-C Module product workmanship warranty 25 years" Temperature Coefficient Voc -0.28%/'C Linear power performance guarantee 30 years Temperature Coefficient Pmax -0.36%/°C >_97.1%end 1st yr NOCT(±2°C) 45'C >_91.6%end 12th yr >_ 85.1%end 25th yr Operating temperature -40/+85'C 82.6%end 30th yr CERTIFICATIONS SHIPPING SPECS ULC ORD C1703,UL1703,CEC listed,UL 61215-1/-1-1/-2,UL 61730-1/-2, Modules Per Pallet: 26 or 26(California) Product IEC 61215-1/-1-1/-2"'.IEC 61730-1/-2"',CSA C22.2#61730-1/-2,IEC 62716 Ammonia Corrosion;IEC61701:2011 Salt Mist Corrosion Certifed,UL Fire Rating:Type 2 Pallets Per Truck 34 or 32(California) Factory IS09001:2015 Modules Per Truck II, 884 or 832(California) ` A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolar.com Certification in progress. PAN files generated from 3rd party performance data are available for download at:silfabsolar.com/downloads 69.4"[1762mm] . 14"[356mm] 41.3"[1050mm] 14"[356mm] T +1888.781.7074 -- - - -- i" IONSOLAR.COM Mounting Hole(x4) _ SILFAB SOLAR INC. 800 Cornwall Ave [12mm] Bellingham WA 98225 USA T +1360.569.4733 info@silfabsolar.com SILFABSOLAR.COM 1.4"[35mm _ E T E o io ' M1770 Port Drive o , m o Burlington WA 98233 USA I w u x M O T +1360.569.4733 3 E 2� ' 240 Courtneypark Drive East 3 0.06" 53.15" a c Mississauga ON 1_5T 2Y3 Canada I T +1905.255.2501 1 t [ 350mm] 61 p +1905.696.0267 Cable Length o 0 Cl Sitfab-SIL-380-HC-20211101 x _TDrainage Hole(x8) l9 ,, - - y � No reproduction o(anykind sallowed without F permission,Data and information is subjectto modifications without notice.©Silfab Solar Inc., 24" 60mm J 2021.Silfab solar"is a trademarkof Snfab Solar Inc. I Data Sheet Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready Enphase IQ 7 MicroT' and Enphase IQ 7+ Micro" IQ 7 and IQ 7+ dramatically simplify the installation process while Microinverters achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy", Enphase IQ BatteryTM, and the Enphase Enlighten T" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable Optimized for high powered 60-cell/120 half-cell and 72- cell/144 half-cell*modules More than a million hours of testing Class II double-insulated enclosure 0 UL listed i Smart Grid Ready i Complies with advanced grid support,voltage and ` frequency ride-through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) *The IQ 7+Micro is required to support 72-cell/144 half-cell modules. To learn more about Enphase offerings,visit enphase.com '0-)I E N P H A S E Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC).._ ._,_. _a. IQ7-60-2-US IQ7PLUS-72-2-US Commonly used modw.__ule..p_ .9__. . 235 W-350 W+ 235 W-440 W+.. airin s Module compatibility 60-cell/120 half-cell PV modules 60-cell/120 half-cell and 72- only cell/144 half-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22V/48V 22 V/60 V Max DC short circuit current(module Isc) 15A 15A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208V/ 240 V/ 208V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peake__..�..,a . _w..., _,.,. _ ...... _ ..... __......._.. _...__,_ I fficiency 97.6°i 97.6°i 97.5 i° 97.3 i CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ament temperature g bi p re ran e -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connectortype MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https:/Zenphase.com/en-us/support/"module-compatibiliiy. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com 40� E N P H A S E ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7,Enphase IQ 7+,Enphase IQ Battery, `/ Enphase Enlighten,Enphase IQ Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.2020-08-12