Report (4) E c o F ci s t e n;,
v For Installers. By Installers.
///
COMPLETE MOUNT
� & FLASHING ASSEMBLY
INSTALLATION GUIDE
REVISION: 04/05/22 VERSION: V2.4
ECOFASTENSOLAR.COM
REVISION:04/05/22 VERSION:V2.4
INSTALLATION ••• Eco Fasten,
For Installers. By Installers.
CLICKING THE PAGE NAME WILL TAKE YOU TO THAT PAGE
TABLE. OF..CONTENTS................................................PAGE..0.1.
FEATURES & BENEFITS PAGE 02
COMPONENTS PAGE 03
INSTALLATION PAGE 04
LINE DRAWINGS PAGE 06
SPECIFICATIONS _� � „ _ PAGE 12
REVISION:04/05/22 VERSION:V2.4 i,�`6i.�`�.
S �
4.
Zo
..• 4
INSTALLATION G F=1
EcoFasten
For w
A4
AP
L
STAtf OF ,y p
A'"i'L '�LOg1u" �
►p ry aurin`baa
ovvvd
' 'q
1,
` fi y
r
�yM
NN afi'
z`�� ykSbb.
1
GF-1
GF-1 is our most versatile solution for composition shingle roofs. Install the flashing
using a single fastener for a quick & easy installation. When using the GF-1 flashing
grommet and an EcoFasten compression bracket, a watertight seal is created,
maintaining the integrity of the roof.
FEATURES
• Mill or black finish
• Patented Watertight Technology
• Installs without removing shingles
• Single lag bolt attachment
• Compatible with a variety of compression brackets
• Florida Product Approved for any combinationof 8"x12"GF-1
flashing with the ClickFit L-foot&Lag Screw
REVISION:04/05/22 VERSION:V2.4
GF=l
C.,> EcoFusten
1
For Installers. By Installers.
SYSTEM COMPONENTS
1
2
3
4
�.I
w
��.-iw NO r iis 60 _, �
1. L-FOOT SCL-101 BLK 3" 4. GF-1 FLASHING GLV MLL 8X12" -
(OTHER OPTIONS AVAILABLE) GALVALUME FLASHING WITH PRE-
INSTALLED EPDM RUBBER GASKET
2. 5/16" LAG BOLT
(AVAILABLE IN 3"AND 4") (AVAILABLE IN 8X10&8X12,WITH MILL&BLACK
FINISH OPTIONS)
3. 5/16" EPDM BONDED WASHER
REVISION:01/05!32 VERSION:V3.1
GF=1
.�INSTALLATION GUIDE ,T'
For Installers. By Installers.
INSTALLING GF-1
Snap horizontal lines across the
roof to mark the mount rows,then
locate the rafter and mark the
installation position of each GF-1
flashing. r i
i
AM
r
Drill a 7/32"pilot hole into the
rafter or structural member for
the lag screw. Backfill with sealant
compatible with the roof type.
Slide flashing up under the next row
of shingles directly above the pilot
hole,taking care to align the hole in
the flashing with the pilot hole.
REVISION:OUSS/I2 VERSION:V2.�
GF=1
1INSTALLCrRoFasten'
For Insta[Lers. By Instatters.
INSTALLING GF-1
Thread the EPDM bonded washer
onto the lag bolt followed by one of
EcoFasten's compression brackets
and then insert the lag bolt into the
gasketed hole in the flashing.
i
j rr
A"
. ..- ow AW
Drive the lag bolt down into the
rafter using an impact driver.
Torque range is between 100-400
torque inch-pounds depending
on the type of wood and time of
year.The visual indicator for proper
torque is when the EPDM on the
underside of the bonded washer
begins to push out the sides as the
washer compresses. Do not over
torque.
REVISION:04/05/22 VERSION:V2A
INSTALL1 TION GUIDE
For Installers. By Instatters.
�Ur- Eco Fasten
CUT SHEET: GF-1 FLASHING GLV MLL/BLK
---
REM NO. PART NUMBER DESCRIPTION QTY. REV
REv. APPROVED
1 750041M GF1-GAL-MLL-812 1 A FOR-1(FCC 0721j
sours
2 150002 5/16 STAINLESS STEEL AND EP DM 1 A
BONDED SEALING WASHER -
i D cn
8.00
,.�..... - , [203.2]
C C
2
I
I
I
12.00
[304.8]
0.02
THIRD ANGLE PROJECTION CMECRE, a o72a m19 10 Mg 4
A trlc arra, rso 1221r`I wnrra.M ovo.. A
_ a o m/ol/mal
INTERPRET DIM AND TOLERANCE INNOVATIVl YOUMIRN iI/nY�
DO NOT SCALE DRAWING PERASMEYIe.51M1-2Do9 �t
P[OfllIIFtl NDC0.RDEMIAL DIMENSIONSIOLERANCES ARE IN:GF-1 FLASHING GLV MLL 8X1 12
INCH,. MILLIMETERS]
1.PACKAGE PER"3012011-PCK" .zz:./-o3D x: / DwC.No.
(GF-1 FLASHING GLV MLL 8X12"50-PACK INST) .zzx:+/-.DID .xx. -.25 301201 RA
ANGLES:+/-1^ SCAIEI'.I
4
Arm
mod
1 •
REVISION:01/05/22 VERSION:V2.4
INSTALL1 TION GUIDE
* EcoFusten,
For Installers. By Installers.
CUT SHEET: L-FOOT L-102 BLK 3"
ITEM NO. PART NUMBER DESCRIPTION QTY. REV.
All
1 450050-01 L-102-3 ANOD BLK I Ol - �t i corrzal oaroznozi
2 150009-08 SS HEX HD CAP SCREW,FULL THD,3/8-16 UNC X 1.25 LONG 1 01
3 150011-03 SS SERRATED FLANGE LOCK NUT,3/8-16 1 02
D D
1
f 3
1 C C
3.00 1
2 1[76.2]I
( 1[477 6.6])
Ali THIRD ANGLE PROJECTION D�
SIA or.� 19,o0 ouoz E INNOVATIVE NOUNilO A
INTERPRET DIM arvD TOLERa cE
DO NOT SCALE DRAWING PER ASME Y14 5[N1-2009 I r�pI yy
RROIRIETARY AND CONNDEMIAL DIMENSIONS TOLERANCES ARE IN. L—FOOT T L-102 BLK3 da
1.PACKAGE PER"3011015-PCK" wcNEs. fMluunETERs1
(L-FOOT L-102 BLK 3"50-PACK INST) 301101 ,
xxx:./-.olo xx../-zs RA
ANGLES'.•/-V
6 4
}z r
/ aevlsioN:aiesr� vErtswn►:v2., �
GF=l
INSTALLATION Zo * Ecokistem
For InstalLers. By Instatters.
CUT SHEET: L-FOOT L-102 MLL 6"
-_b _..__. 5_.--. 4 --� I -
--- -- RENSpNt
ITEM NO. PART NUMBER DESCRIPTION QTY. REV. DEsce PnoN AfaaovED
1 450082-02 L-102-6 1 01 RELEASE MMDEG EoaMAi(ECO 0222) RAni/Ps
2 150009-0B SS HEX HD CAP SCREW,FULL THD,3/8-16 UNC X 1.25 LONG 1 01
3 150011-03 SS SERRATED FLANGE LOCK NUT,3/8-16 1 02
D
cni
Apr%r
I
I
c G
6.00
3 [152.4])
2
OXON
B B
3.00
2.00
50.8
THIRD ANGLE PROJECTION °" wrosrm D C3
A EN,.sER./N oarosrso2
Mw nPRR.MD eros/mei 0 A
.. G.A. D
INTERPRET DIM AND TOLERANCE INNOVATIVE YOUN71YGfVilfllt
DO NOT SCALE DRAWING PER ASME YI4.SIM1-2M9 p,
DMENSIONS TOLERANCES ARE IN:
PROPRIETARY AND CONfIDENIIAL IN H MII1lM RS L-FOOT L-102 MLL 6"
1.PACKAGE PER"3011016-PCK" c '-
xx.+/-030 x:,/..)5 3011016
(L-FOOT L-102 MLL 6'50-PACK INST) xxxmD xx..i-25 RA
ANGLES:+/.t° —L EIGH
6 4 3 2
1
PAGE
08 TuR
REVISION:04/05/22 VERSION:V2.4
GF=1
.•• Eco Fasten
INSTALLATION For Installers. By Instatters.
CUT SHEET: L-FOOT SCL-101 MLL/BLK 3"
_... - I
ITEM NO, PART NUMBER DESCRIPTION QTY. REV. DEsca vlro�ns oNs ,A,E ovE
1 450049-02 L FOOT W/STANDARD DIMPLE AND OPEN SLOT.3 IN TALL MLL 1 Ol ESDEC EORwa IECo-) Duos/mEl �A-
2 150009-08 SS HEX HD CAP SCREW,FULL THD,3/8-16 UNC X 1.25 LONG 1 Ol
3 150011-03 SS SERRATED FLANGE LOCK NUT,3/8-16 1 02
D cn
1
i
C C
3.0
[76.2])
B B
1.88
3
2
THIRD ANGLE PROJECTION
cNEcx= a/os/mn IL'J� IL��
A ... eHo.vv_ o•msizoz A
M o<vPx. amsrmzi �
XJTEPIRET DIM ANO TOLERANCE INNOVATIVE MOYNAN�TTf1�YE
DO NOT SCALE DRAWING PERASMEYI<sIM)-2Dov L-FOOT SCL-101 MLL 3"
1.PACKAGE PER"30110 1 7-PCK" PROPRIPIARY AND CONEIDENNAI DIMENSIONS TOLERANCES ARE IN:
N HES. MR.IV.IEI RS
(L-FOOT SCL-101 MLL 3"50-PACK INST.) IIc.Nc.
3011017
A
6 1 1 4 ]�
r �.r
f"I
REVISION:04/05/22 VERSION:V2.1
GF=l
INSTALLATION i.llcoFasten
•
CUT SHEET: CF UNIV L-FOOT MLL 3" - 2012022
REMIND. PART NUMBER DESCRIPTION QTY. REV. ..DRev""
DALE covin
1 PEA
New EAS
750120 CLICKFITLFOOT ASSEMBLY 1 A aftE*o........
..spec EocNA.leco eieol osnRra°xl RAD/xs
i
D D
1
i
f
C C
/ 2.76
i[70.1]
B B
�k
THIRD ANGLE PROJECTION
A —( cl
ff DCS
os r o
O A
INTERPRET DNn AND TOLE NCE INNOVATIVE YOYN41RtiiYf7E-
DO NOT SCALE DRAWING PPR ASME YI451m]2oa9
PROPRIETARY AND CONNDENIUL DRAENSIONS TOLERANCES ARE IN: CF UNIV L-FOOT MLL 3
IN H MILLIMETERS
1.PACKAGE PER"2012022-PCK" sue
(CF UNIV L-FOOT MLL 3"50-PACK INST.( xxx..r mo xx./-ss 2012022 q
4 1
NG
ALES:/-1°
€Ts
PAGE
REVISION:04/05/22 VERSION:V2-4
GF=l
1 1TION .•. , , •
INSTGUIDE •
A,
CUT SHEET: RI COMP
SLIDE AL BLK - 2011013
REM NO. PART NUMBER DESCRIPTION QTY. REV. aevrsloNs -
aay. oescaRnoN ogre ovEo
A NEwa
1 450092-01 ROCKIT V3 SLIDECOMP 1 01 ELEASETO Esoec Eoa u.lEco+»sl om./vsi aouRs
2 53-100-010 LAG SCREW,5/164",THREAD 3".EPDM BACKED 1 C
WASHER
D
cn
I
C
C
1 4.00
[101.6]
B B
i
`x r:
4`
THIRD ANGLE PROJECTION o ozrmizon D
anw" awo "
�nECFeo vs arlmmzl .. •,
rnFCAPPa.o wn vsozl A
00
INTERPRET DIM AND TOLERANCE INNOVATIVE MOYNTNi iV/T•W
DO NOT SCALE DRAWING PER ASME n4sIM1-2aov p COMP
p y
PROPRIETARY AN CCONFIDEMIAL DIMENSIONS TOLERANCES ARE IN: RI COMP SLIDE AL BLK
IN H mRLImETER
1.PACKAGE PER"2011013-PCI" 201101$
(RI COMP SLIDE AL BLK 50-PACK INST.) .zxx:«/_.olo xx:*/-s5 aA
ANGLES:i/-i° wilGln:
REVISION:04/0582 VERSION:V2.4
'100 G F=1
) tEcaFasten'
INSTALLATION
SYSTEM COMPONENTS
1 . GF-1 Flashing:
All flashing options come with a pre-installed integrated EPDM grommet
and one bonded stainless steel EPDM washer. Flashing are available in three
options:
1. 8 x 12" .032 gauge galvalume with mill or black (kynar painted) finish.
2. 8 x 10" .032 gauge galvalume with black (kynar painted) finish.
3. 8 x 12" .032 gauge aluminum with black (kynar painted) finish.
2. Aluminum Compression Bracket:
Compatible with a variety of EcoFasten compression brackets. EcoFasten
compression brackets are made out 6000 series aluminum with options
available for mill or black finishes depending on the bracket. "
3. Recommended Fasteners
5/16"x4" lag bolts. 3" option also available. -<
4. Recommended Sealant:
If required by roof manufacturer, sealant shall be roof manufacturer `
k
approved.
DELIVERY / STORAGE / HANDLING `
Inspect material upon delivery. Notify manufacturer within 24 hours of any missing
or defective items. Keep material dry, covered and off the ground until installed. . ,
REVISION:04/OS/u VERSION:V2.4
F=1
),,' '
INSTALLATION GUIDE
For Installers. By Instatters.
FLORIDA PRODUCT APPROVAL
Approved for any combination of 8"x12" GF-1 flashing with the ClickFit L-foot & Lag
Screw.
v
PATENTS
Visit www.efpatents.com for patent information.
DESIGN REQUIREMENTS
1 . Bracket spacing to be recommended by project engineer. __, }
2. It is important to design new structures or assess existing structures to make
sure they withstand retained loads.
EXAMINATION
1 . Substrate: Inspect structure on which brackets are to be instalted.aand_veri�y._ ----- .— .:,_
that it will withstand any additional loading that may be incurred.
2. Notify General Contractor of any deficiencies before installing EcoFasten
Solar brackets. `, '
3. Verify that roofing material has been installed correctly prior to installing
solar attachment bracket.
INSTALLATION
Comply with architectural drawings and project engineer's recommendation for '
location of system. Comply with Manufacturer's written installation instructions for
installation and layout.
EcOFQstem 4141 W. VAN BUREN ST, SUITE 2, PHOENIX AZ 85009
An Esdec Solar Group Company 1 - 8 7 7 - 8 5 9 - 3 9 4 7 1 INFO @ E C O F A S T E N S O L A R. C O M
fe.