Report (3) City of Tigard
Building Division R,EE:(3)E
13125 SW Hall Blvd,Tigard,OR 97223 '� )
Phone: 503.718.2439 Fax: 503.598.1960 1 L
Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 8133 SW Bonita Rd
City: Tigard Zip: 97224
Owner's Name: James Cessna Date: 07-08-2022
Contractor's Name: ION Developer LLC CCB #: 230394
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? FRI No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure F91 Yes If"Yes", qualifies for
"C"or less? E] No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes FX-1 Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
Yes the prescriptive path.
above
❑ No
I
1:/Building/Forms/PhotoVoltaic-Checklist02-01-1 I.docx
Document Ref:XFMVVT-JM2MU-QHUJV-EEVGT Page 5 of 8
Is the construction
material wood and does RX Yes
Type of the construction qualify If"Yes", qualifies for
Construction E:1as "conventional light NO the prescriptive path.
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ❑X Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. ❑ Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Is the combined weight X❑ Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance X❑ Yes
with Section 305.4(3)of If"Yes", qualifies for
the20102010 Oregon Solar NO the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
❑X of composition
shingle.
Is the roof mounted X❑ Yes
Connections of solar assembly If"Yes", qualifies for
the solar assembly connected to roof ❑ No
to the roof framing or blocking the prescriptive path.
directly?
2
I:/Building/Forms/PhotoVoltaic-ChecklistO2-01-1 l.docx
Document Ref:XFMWTJM2MU-QHUJV-EEVGT Page 6 of 8
Is the gauge 26 or less? ❑ Yes If"Yes", qualifies for
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
❑ Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted If the spacing falls
Spacing Minimum 24 inches
solar systems p g of clamps?p within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam
prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of ElYes If"Yes", qualifies for
fastener? the prescriptive path.
❑ No
Is the roof decking of
WSP min. t/2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof Yes the prescriptive path.
surface. ❑ No
3
1:/Building/Forms/PhotoVoltaic-Checklist02-01-1 l.docx
Document Ref:XFMWT-JM2MU-QHUJV-EEVGT Page 7 of 8
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV modules stem racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: SILFAB
Model Number: SIL-380 HC
Listing Agency:
4
1:/Building/Forms/PhotoVoltaic-Checklist02-01-1 l.docx
Document Ref:XFMWT-JM2MU-QHUJV-EEVGT Page 8 of 8
Signature Certificate
Reference number:XFMWT4M2MU-QHUJV-EEVGT
Signer Timestamp Signature
Dustin Davidson � �
Email:dustin.davidson@ionsolar.com
Sent: OS Jul 2022 21:34:26 UTC
Signed: 08 Jul 2022 21:34:27 UTC
IP address:66.219.246.14
Location:Provo,United States
Document completed by all parties on:
08 Jul 2022 21:34:27 UTC
Page 1 of 1
Signed with PandaDoc [Nil N M
PandaDoc is a document workflow and certified eSignature
sorution trusted by 30,000+companies worldwide. M1