Report (2) City of Tigard V R,E irc ­) I Building Division �i­ 1_,;,- 13125 SW Hall Blvd,Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 1 T v, (),P- TIGARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System M � Fug -2-Z- — Property Information Installation Address: 8175 Southwest Pfaffle Street City: Tigard Zip: 97223 Owner's Name: Aldo Ruiz Date: 07-12-2022 Contractor's Name: ION Developer LLC CCB #: 230394 Design Parameters of the Prop erty/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? Fx_1 No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes 21 Yes the prescriptive path. and/or their accessory Ground structures. El No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for Ej Yes the prescriptive path. above ❑ No I L/Building/Forms/PhotoVoltaic-Check list02-01-1 I.docx Document Ref:S41XT-93M3V­0M7C3-6UDEG Page 5 of 8 Is the construction material wood and does 0 Yes Type of If"Yes", qualifies for the construction qualify Construction as "conventional light F-1Nothe prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ❑ Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. ® Yes If"Yes", qualifies for the prescriptive path. ❑ No Is the combined weight X❑ Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ❑ Yes with Section 305.4(3) of If"Yes", qualifies for the20102010 Oregon Solar NO the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. Q of composition shingle. Is the roof mounted 0 Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/PhotoVoltaic-ChecklistO2-0I-1 Ldocx Document Ref:S41X7-g3M3V-0M7C3-6UDEG Page 6 of 8 Is the gauge 26 or less? ❑ Yes If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ Yes If"Yes", qualifies for the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? El Yes the prescriptive path. ❑ No Is the roof decking of WSP min. '/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof 0 Yes the prescriptive path. surface. ❑ No 3 1:/Building/Forms/PhotoVoltaic-Checklist02-01-1 Ldocx Document Ref:$41XT-93M3V-OM7C3-6UDEG Page 7 of 8 Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV modules stem racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: SILFAB Model Number: SIL-380 Listing Agency: 4 1:/Building/Forms/PhotoVoltaic-Checklist02-01-1 l.docx Document Ref:S41XT-93M3V-OM7C3-6UDEG Page 8 of 8 r Signature Certificate Reference number:S41XT-93M3V-OM7C3-6UDEG Signer Timestamp Signature Samuel Wilson ._...Ty.. _. . Email:samuel.wilson@ionsolar.com Sent: 12 Jul 2022 18:07:02 UTC � "� Signed: 12 Jul 2022 18:07:03 UTC IP address:216.21.162.207 Location:Provo,United States Document completed by all parties ori: 12 Jul 2022 18:07:03 UTC Page 1 of 1 Signed with PandaDoc PandaDoc is a document workflow and certified eSignature solution trusted by 30,000+companies worldwide. �1