Loading...
Permit Support Document (41) FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT Transmittal Letter 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.ti 7ar� d-or.grov TO: Tom Hochstatter DATE DEPT: BUILDING DIVISION FROM: Target(Agent-Alexander Lampert) COMPANY: Lampert Group PHONE: 312.522.5835 By _ EMAIL: AML @Lampertgroup.build RE: 9009 SW HALL BLVD,TIGARD, OR 97223 ELC2022-00251 (Site Address) (Permit Number) 2022 TARGET REMODEL- ELECTRICAL REV (Project name or subdivision name and lot number) ` ATTACHED ARE THE FOLLOWING ITEMS: — Co ies: Description: Copies: Description: - 2 Additional set(s) of plans. 2 Revisions: Elec Revision narrative Cross section(s)and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: Electrical portion of the post approval revision to add-a new fire pump room and address required changes to plumbing repair scope. FOR OFFICE USE ONLY Routed to Permit Technician: Date: V,-- 4 a Initials: Fees Due: es ❑No Fee Description: Amount Due: $ $ $ Special Instructions: Reprint Permit(per PE): ❑ Yes o ❑ Done Applicant Notified: Date: '7/Al/AY I Initials: Electrical Permit Application FOR OFFICE USE ONLY City of Tigard Received Pennit#:ELC2022-00251 • 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Revicw 2 = Phone: 503.718.2439 Fax: 503.598.1960 Date/By, Related Permit#: Inspection Line: 503.639.4175 Ready Datc! y: Juris: 0 See Page 2 for a Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF WORK PLAN REVIEW ❑New Construction ®Addition/alteration/replacetttcnt Please check all that apply(submit 2 sets of plaits w/items checked): ® ❑Service or feeder 400 amps or more ❑Building over three stories. Demolition E]Other: where the available fault current ❑Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or Cl Floating buildings- 1- uildings.l-and 2-family dwelling ®Commerciallindustrial ❑Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural ❑Multi-family E]Master builder amps for all other installations. buildings. ❑Other: ®Fire pump. ❑Installation oft50 KVA or JOB SITE INFORMATION AND LOCATION ®Emergency system. larger separately derived Job#: lob site address:9009 SW Hall BLVD [I Addition of new motor load of system. IOOHP or more. ❑"A","E","I-2","I-3". occupancy. city/state/ZIP: Tigard, OR 97223 ❑Six or more residential units. ❑Recreational vehicle arks. ❑Health-cart facilities. P Suite/bldg./apt.#: Project name:2022 TARGET REMODEL ❑Hazardous locations. ❑Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Cross Street: SW Eliander Ln D"cri tion I Oty. I Each Tatat New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. I,000 sq.ft.or less 168.54 4 Tax map/parcel#: 1 S 126CA01100 Ea.add'l 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential with above .ft.) 75'00 2 Revision for Electrical Limited energy,multi-Family residential with above sq.ft.) 75.00 2 Renewable Ener [I See Page 2 0, PROPERTY OWNER ❑ 'TENANT Services or feeders installation,alteration,and/or relocation Name:Target Corporation 200 amps or less 1 100.70 100/70 2 Address:50 S 10th Street Suite 400 TP3-11 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Minneapolis, MN 55403 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 5936 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 ❑ APPLICANT ® CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name:Lampert Group above service or feeder fee, 57.42 137.10 each branch circuit Contact name:Leif Erickson B.Fee for branch circuits without service or feeder fee,first 56.18 2 Address:10061 Riverside Dr. branch circuit City/State/ZIP: Toluca Lake, CA 91602 Each add'I branch circuit 7.42 2 Miscellaneous service or feeder not included Phone:(312 )956-4092 Fax: :( ) Each manufactured or modular dwelling,service and/or feeder 67'84 2 Email:LRE@Lampertgroup.build Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: Cochran Inc Sign or outline lighting 67.84 2 Signal cirmit(s)or limited-energy Address: 7550 SW Tech Center Dr#224 panel,alteration,or extension. ❑ See Page 2 2 City/State/ZIP:Tigard, OR 97223 Each additional inspection over allowable in any of the above Additional inspection(I hr min) 66.251 hr Phone:(971)205-4242 Fax:(971 )205-4268 Investigation(I hr min) 90.001 hr Industrial plant(I hr min) 78.18!hr Email: eholmes cochraninc.com Inspections for which no fee is 90.00/hr CCB Lic.: 72942 Electrical Lie.: 87-5 6C`, uprv. Lie.:6277S specifically listed Y,hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: . - _ Subtotal: Print name: Mike Grogan Date: 6,1 0,22 ❑Plan Review Required(25110 of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Leif Erickson Date:6/9/22 days after it has been accepted as complete. * Number of inspections allowed per permit. I.,Build trig Nrmfts'fiU_PcrinitApp_FLR_Gltt.doe ttc%(16,1?1015 44o-4t;i 5'ro i o5rco o%k r B Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: [RESIDENTIAL WORK ONLY: FEE SCHEDULE ee for all residential systems combined: $75,00 Oestrl tlnn Renewable electrical energy systettts:heck Type of Work Involved: 5 kva or less 100 70 , ❑ 5.01 to 15 kva 133.56 Audio and Stereo Systems* 15.01 to 25 kva tx1.34 ❑ Burglar Alarm nd encratIon systems in excess of 25 kva: 25.01 to 50 kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 ? >100 kva(fee in accordance Heating, Ventilation and Air Conditioning with OAR 918-309-0040) 552.26 2 System* Solar generation systems in excess of 25 kva: Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.01 3 F] Each additional ins ection over allowable in any of the above: Other: Each additional inspection is 66.25F hr charged at an hour) (I hr min) Inspections for which no fee is specifically listed(-hr min) 90,00/hr COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75,00Subtotal(Enteron Page 1): (SEE OAR 918-309-0000) Nimtbcr of inspections allowed per permit. Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire AIarm Installation ❑ HVAC ® Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:Huildint Permits EL(-Permit WELR_EREAm Rei 06 17 2015 ~ � T-0345 Tigard, OR '11 March 2022 Delta [I2833 CHANGES TO DRAWINGS ELECTRICAL L�ii / U� \K��MU ED111 - ELECTRICAL DEMOLITION PLAN ° Revised relocated lighting for new water service room E111 - LIGHTING PLAN ° Revised relocated lighting for new water service room E211 - OVERALL POWER & SYSTEMS PLAN ° 1/E211 - POWER AND SYSTEMS PLAN o Added Ca|)out7/E3Z1toplan ° 3/E211 - REAR ELECTRICAL ROOM 130 POWER & SYSTEMS o Added existing ATS2panel toplan o Added C8for new TE 2 E221 - ROOF PLAN ° Added PRV and GlVto roof plan E331 - FLEX FULFILLMENT POWER & SYSTEMS PLANS ° 7/E3Z1 - WATER SERVICE - FIRE PUMP o View added toplan ° Added keynotes 296, 372, and 922 to plan E521 - ELECTRICAL DETAILS ° Added view 17/ES31 E551 - ELECTRICAL DETAILS ° Added view 1S/ES51 E601 - ELECTRICAL DETAILS ° Adjusted quantity of H7 fixtures ° Added Electrical Jockey Pump Schedule tosheet ° Added Electrical Power Roof Ventilator Schedule to sheet ° Added Electrical Water Jacket Heater Schedule to sheet ° Added fault current for new panel tnsheet E611 - ELECTRICAL ONE-LINE DIAGRAM ° Updated one-line diagram for added fire pump and appurtenances ° Added Transformer schedule tosheet E621 -PANELBOARD SCHEDULE • Added circuit 34 on panel LP-2 E622 - PANELBOARD SCHEDULE • Added new panel LPE-2 to sheet • Added circuits for ATS panel and JP-1 to panel HL-2 E911 - FIRE ALARM SYSTEM INITIATING &SIGNALING DEVICE PLAN • 4/E911 - RISER DIAGRAM o Updated views to show new fire alarms for water service room • 5/E911 - WATER SERVICE ROOM o Expanded view to add fire pump SOW E961 - INTRUSION SYSTEM FRONT AREA PLAN • Added 4/E961 to sheet Page 2of2