Loading...
Specifications PL M - zz-oma 2,7 g- 10 110 sw illi v,uOv5 AI,,- B(Ij. B r4_.J e (P "I Il Y OF!It ARLj 9-1 ZZ3 1JILDING DIVISIOn CITY OF TIGARD Approved...............................�] Conditionally Approved..............[ ] See Letter to: Fol low.................. Attached................[ J Permit Number: 'PL M Jo3a-00ar)8 Address: 16116 Sdj. N(w,6r ,% Asa S31a11 13. 54-,& ( 2 ) l•�or DKC"N By: —[date: 2-25- 2022 M O F(oor 51v4K OFFICE COPY ------ - s w c,4'f V N OZ o Fo (, ,M OP 'tsk . � o 0 GI �[ H � t s ,mak • IH 000 35 C�PM � 130• ` (b�. s kers 1z" 4 k c(o V4 �0✓�Z 0✓���c I C�'�G.r j7uL�' r SPECI FICATION AN D SU BM ITTAL K 1 .01W G B2 urr�o�rI�A� 35/50 GPM Grease Interceptor for Indoor Use :3UILDING DIVISION 23" _ 35" o v ®®° (58 cm) (89 cm) o®oo°o --Z-u-2-20- ®o°o 00 00 00 0 0 0 0 o1:;W-12:0 oo °®o ° o®°o 0 0=0 000 00 0 0000 0 � 0 0 0 0 0 00 0 0 5" o �000000000000000 �go o° ® °—- ° — (13 cm) ®°®° �°moo Lc ' 13-3/4„ �1 0® ®� :=0 1 > (35 cm) 8-3/4" (22 cm) 1 0 s OFFICE COPY 0 This unit is certified to ASME A112.14.3(Type C)and Satisfies Miami DERM 99%efficiency requirements CSA B481.1 at two different flow rates and includes the internal flow when at least 2 units are installed in series MEA controls for both.External flow control with vent not required. SUBMITTAL Standard Options Location:indoor ❑-FO:fixed outlet diffuser Installation:above/below grade ❑FCRt(xl):>2-1/8"-12"field cut riser Flow Rates/Grease Capacities: ❑FCR1(x2):>12"-24"field cut risers 35 GPM(2.2 L/s) /130.5 lbs.(59.2 kg) ❑CC1:membrane clamping collar kit(requires FCRI riser) 50 GPM(3.2 L/s) /127.6 lbs.(57.9 kg) ❑PPI:pumpout port kit Solids Capacity:1.8 gal.(6.8 L) ❑SGK2:support gusset kit Liquid Capacity:20 gal.(75.7 L) Weight:49 lbs.(22.2 kg) ❑PLAIN-EA-24:2"(50 mm)plain end fitting Connections:3"(75 mm)and 4"(100 mm)plain end ❑FPT-EA-34:4"x 3"(100 mm x 75 mm)FPT fitting Cover bolted gas/water tight polypropylene with 1,000 Ib.load rating ❑FPT-EA-23:3"x 2"(75 mm x 50 mm)FPT fitting when unit is buried with FCR1 riser Approval Signature: Date: Company: Specifying Engineer: Engineering Firm: 10 JE MODEL NUMBER: DESCRIPTION:35/50 GPM Polyethylene Grease Interceptor • G B2 • PART#:4065-001-05 DWG BY:B.Karrer DATE:4/10/2019 REV: ECO: Page 1 of 4 A SPECIAL . . . For Schier -Failure to follow this guidance . . . . . A WARNING! DO NOT AIR TEST UNIT OR RISER SYSTEM! CAUTION! Do not install this unit in any manner Doing so may result in property damage,personal injury or death. except as described in these instructions. Installation Instructions High Temperature Kitchen Water Installation instructions and additional installation components are included with the instructions cold water supply line interceptor.Read all instructions prior inside _-- high temperature effluent(>150°F) to installation.This interceptor is approved backflow prevention assembly intended to be installed by a licensed --- DTV(drain water tempering valve) plumber in conformance with all local codes. When Installing Interceptor Inside Interceptor If your dishwashing sink(s) Interceptor discharges into a floor drain/sink(drain),you �� j •+s+yi must regulate the flow into the drain to avoid an directly connected indirectly connected overflow of water onto the kitchen floor.This can be Interceptor If water is entering the interceptor at excessive temperature(over done by installing a valve Fernco or similar or flow restriction ca rubber flow ► 150°F),a drain water tempering valve(DTV)and approved backflow p on restriction end cap J prevention assembly must be installed.Most state and local the sink piping that plumbing codes prohibit water above 150°F being discharged into discharges into the drain. the sanitary sewer.Water above 150°F will weaken or deform PVC See drawing for guidance.For detailed guidance on indirect Schedule 40 pipe,poly drainage fixtures like interceptors and erode connections,go to: the coating of cast iron(leading to eventual failure). webtools.schierproducts.com/Technical_Data/Indirect_connections.pdf Hydrostatic Slabs(or Pressure Slabs) ODOR ALERT! Do not install air When installed under a concrete slab subject to hydrostatic pressure gap on outlet side hydrostatic slab(slab of interceptor. designed to withstand upward lift,usually caused by hydrostatic pressure)interceptor waterconcretetight must be enclosed in a vault watertight concrete vault. 0 MODEL NUMBER: DESCRIPTION:35/50 GPM Polyethylene Grease Interceptor G B2 • PART#:4065-001-05 DWG BY:B.Karrer DATE:4/10/2019 REV: ECO: Page 2 of 4 ' SPECIAL PRECAUTIONS• For Schier Grease Interceptor Installations-Failure to follow this guidance voids High Water Table Installations Fully Support Base of Unit Interceptors and risers are not designed Install unit on solid,level surface in concrete floor for direct burial p to withstand water table heightin max water table height contact with the entire footprint of excess of the top of the unit when buried unit base;for suspended (see figure).If it is possible for this to17 nstallations design trapeze to Interceptor occur,install the interceptor and risers in support the wet weight of the unit. a water-tight concrete vault or backfill ��VInterceptor Do not partially support unit or with concrete or flowable fill(wet suspend unit using metal concrete and flowable backfill should be U-channel to create a trapeze. poured in stages to avoid crushing the suspended installation interceptor).At risk areas include but are not limited to tidal surge areas, floodplains and areas that receive storm water.Great Basin'm models that are direct buried in high water table scenarios must be installed Support Inlet and Outlet Piping with an anchor kit.Models GB-50,GB-75,and GB-250 use model AKl anchor kit.Model GB-500 uses model AK2 anchor kit for use with For above grade installations ensure pipe supports deadmen anchors.Models GB-1000,GGI-750 and GGI-1500 use model heavy inlet and outlet piping(such as AK3 anchor kit for use with deadmen anchors. cast iron or long runs)is properly supported or suspended during the Interceptor entire installation process to prevent Flush-to-Grade Burials connection failure or damage to Flush-to-Grade buried installations bulkhead fittings. (without a riser)are not recommendedF7 for heavy foot traffic areas without the use of an internal gusset support kit SGK2(for G62)or SGK3(for GB3). DO NOT COMPACT BACKFILL Interceptor W MODEL NUMBER: DESCRIPTION:35/50 GPM Polyethylene Grease Interceptor G B2 • .• PART#:4065-001-05 DWG BY:B.Karrer DATE:4/10/2019 REV: ECO: ...Mir.Mir. N.T.-FEEZ. - Page 3 of 4 SPECIFICATIONS Notes TOP VIEW 1. 4"FPT inlet/outlet with 3"and 4"plain end fittings. 2. Unit weight-49 lbs.(wet weight 216 lbs.) 3. Capacities- Liquid:20 gal. 35" @35 GPM-Grease:130 lbs. 17.8 gal. @50 GPM-Grease:127 lbs. 17.3 gal. outlet"A" Solids:1.8 gal. L(Optional) 4. Built-in flow control. 5. For gravity drainage applications only. 6. Do not use for pressure applications. °o°o°Oo o°o 7. Cover placement allows full access to tank for proper maintenance. Ao°°°°°o ® °°°°o°o° A 8. Vent not required unless per local code. 0 0 0 0 0 0 9. Engineered inlet and outlet diffusers are oo°°o°o removable to inspect/clean piping. 23" o opo oe moo° 1 10.Inte Integral air relief anti-siphon. Inlets a o 0 0 0 o Outlet"B" 9 / p 000000 0000°00 (Standard) Engineer Specification Guide °o°o°o°o o°o°o°o° Outlet toot must face this Schier Great BasinTm grease interceptor model #GB20 0 0 0°0 0 0°°°°° direction in all shall be lifetime guaranteed and made in USA of o°o°0 0 0°0 oa - o° °o o configurations seamless,rotationally-molded polyethylene. Interceptor shall be furnished for above or below Outlet"C" grade installation.Interceptor shall be certified to (optional) 12 7/16" ASME A112.14.3(type C)and CSA B481.1,with field cut riser system,built-in flow control and three outlet options.Interceptor flow rate shall be 35 or 50 GPM. Interceptor grease capacity shall be 130 lbs.@ 35 GPM or 127 lbs.@ 50 GPM.Cover shall provide water/gas-tight seal and have minimum 450 lbs. SECTION A-A load capacity. Certified Performance q of 4"FPT See Note#10 Great BasinTm hydromechanical grease interceptors are inlet&outlet o 21-1/2"Cover third party performance-tested and listed by IAPMO to ASME#A112.14.3 and CSA B481.1 grease interceptor standards and greatly exceed requirements for grease 5" separation and storage.They are compliant to the Uniform Plumbing Code,the National Standard 13-3/4' Plumbing Code,the National Plumbing Code of Canada, i and the International Plumbing Code. 8-3/4" 6-3/4"invert UPC Engineered inlet Static water line c ® and outlet diffuser OUTLET END VIEW Rated Grease Capacites �1 for Units Piped in Series 23 —{ No.of Units Removal Efficiency in Series 97.8% 99%* - I2 274lbs. 180 lbs. NOTE:Flow rate for 2 GB2 units piped in series is 35 GPM only *Satisfies Miami DERM 99% efficiency requirements MODEL NUMBER: DESCRIPTION:35/50 GPM Polyethylene Grease Interceptor GB2 PART#:4065-001-05 DWG BY:B.Karrer DATE:4/10/2019 REV: ECO: Page 4 of 4 John ITEM#: QTY: y �� BOOS MODEL#: JUN 1 ° Z02 Since 1887 PROJECT NAME: CITY OF IG a DIVI N zsa�as "E3S8-201B" - 3 COMPARTMENT "E-SERIES" SINKS �• WITH TWO DRAIN BOARDS AND GALVANIZED LEGS FEATURES: CONSTRUCTION: • 18GA STAINLESS STEEL TOP: STAINLESS STEEL SINKS ARE TIG WELDED, • TYPE 300 STAINLESS STEEL WITH#4 POLISH, SATIN EXPOSED WELDS ARE POLISHED TO MATCH FINISH ADJACENT SURFACE • 12"AND T14"DEEP BOWLS BASE: GALVANIZED BASE • ALL CORNERS, BOTH VERTICAL AND HORIZONTAL, COVED AT 3/4"RADIUS MATERIAL: • BOTTOMS OF BOWLS FORMED FOR DRAINAGE TO 3-1/2"DIAMETER DIE STAMPED OPENING BOWLS&TOP: 18GA TYPE 300 STAINLESS • FULL LENGTH 10" HIGH BOXED BACKSPLASH,WITH STEEL WITH#4 POLISH, SATIN FINISH 2"RETURN TO WALL AT 45 DEGREE AND 1"TILE EDGE LEGS: 1-5/8"ROUND O.D. GALVANIZED STEEL • 1" FAUCET HOLES IN BACKSPLASH GUSSETS: GALVANIZED STEEL • ALL OUTSIDE CORNERS OF ASSEMBLY ARE BULLNOSED FEET: 1"ADJUSTABLE PLASTIC BULLET FEET TO PROVIDE SAFE,CLEAN,AND POLISHED EDGE • STANDARD STAINLESS STEEL LEGS 1-5/8" DIAMETER • LEGS LOCATED DIRECTLY UNDER SINK BOWLS, PROVIDING INCREASEDE STABILITY AND MAX WEIGHT SUPPORT YIIMMN E �N E3S8-24-14 OFFICE COPY 10" DEEP - 3 COMP SINKS - 18GA 14" DEEP - 3 COMP SINKS - 18GA 13OWL SIZEcs es L �•Ty • a a R C E3S8-1014-10T15 10" X 14"X 10" E3S8-15-14T15 15" X 15"X 14" E3S8-1620-14T18 16"X 20" X 14" 12" DEEP - 3 COMP SINKS - 18GA E3S8-18-14T18 18" X 18" X 14" :. e E3S8-18-14T24 18"X 18"X 14" R E3S8-1620-12T18 16" X 20"X 12" E3S8-1824-14T24 18" X 24" X 14" E3S8-18-12T18 18" X 18" X 12" E3S8-24-14T24' 24" X 24"X 14" E3S8-1416-12-T12 14" X 16"X 12" E3S8-2030-14T24 20" X 30" X 14" WITH TWO SETS OF FAUCET HOLES 146 "E3S8-2DB" - 3 COMPARTMENT "E-SERIES" SINKS DETAILED SPECIFICATIONS 10" DEEP - SINK DIMENSIONS BOWL DIMENSIONS i n/4 12" 10" 10" 39- 10" X 14" 19-7/8" 14" 10" 12" DEEP - SINK DIMENSIONS 16" X 20" 25-1/2" 20" 12-15/16" ! 18" X 18" 23-1/2" 18" 11-15/16" 14-1/4" 12" 10" 43-3/4" 18" X 24" 29-1/2" 24" 14-15/16" 14" DEEP - SINK DIMENSIONS 24"X 24" 29-1/2" 24" 14-15/16" ! 16-1/4" 14" 10" 43-3/4" 1C I I fiI t # f D H- SIZE O O O 35 1/4 I i r ICY 10" DEEP - 3 COMP SINKS - 18GA E3S8-1014-10T15 10"X 14" X 10" 60"X 19-7/8" 15" 95 12" DEEP - 3 COMP SINKS - 18GA rill 99! E3S8-1620-12T18 16"X 20"X 12" 84"X 25-1/2" 18" 240 E3S8-18-12T18 18" X 18" X 12" 90"X 23-1/2" 18" 153 E3S8-1416-12-T12 14" X 16"X 12" 66" X 21-1/2" 12" 200 14" DEEP - 3 COMP SINKS - 18GA E3S8-15-14T15 15"X 15"X 14" 75"X 20-1/2" 15" 231 E3S8-1620-14T18 16" X 20" X 14" 84" X 25-1/2" 18" 202 E3S8-18-14T18 18" X 18" X 14" 90" X 23-1/2" 18" 255 E3S8-18-14T24 18" X 18" X 14" 102" X 29-1/2" 24" 265 E3S8-1824-14T24 18" X 24" X 14" 104" X 29-1/2" 24" 288 E3S8-24-14T24` 24" X 24" X 14" 120" X 29-1/2" 24" 370 E3S8-2030-14T24 20" X 30"X 14" 108" X 35-1/2" 24" 291 'WITH TWO SETS OF FAUCET HOLES SOME UNITS SHIP UNASSEMBLED FOR REDUCED SHIPPING COST.ALL DIMENSIONS ARE TYPICAL.TOLERANCE+/ .500" John Boos&Co.is constantly engaged in a program of improving products and therefore reserves the right to change specifications without prior notice. i