SPECI FICATION AN D SU BM ITTAL
K 1 .01W
G B2 urr�o�rI�A�
35/50 GPM Grease Interceptor for Indoor Use :3UILDING DIVISION
23"
_ 35" o v ®®° (58 cm)
(89 cm) o®oo°o --Z-u-2-20-
®o°o
00 00 00 0 0 0 0
o1:;W-12:0 oo °®o ° o®°o 0 0=0 000 00
0 0000 0 � 0 0 0 0 0 00
0 0
5" o �000000000000000
�go o° ® °—- °
—
(13 cm) ®°®° �°moo Lc ' 13-3/4„
�1 0® ®�
:=0 1 > (35 cm)
8-3/4"
(22 cm) 1 0
s
OFFICE COPY
0 This unit is certified to ASME A112.14.3(Type C)and Satisfies Miami DERM 99%efficiency requirements
CSA B481.1 at two different flow rates and includes the internal flow when at least 2 units are installed in series
MEA controls for both.External flow control with vent not required.
SUBMITTAL
Standard Options
Location:indoor ❑-FO:fixed outlet diffuser
Installation:above/below grade ❑FCRt(xl):>2-1/8"-12"field cut riser
Flow Rates/Grease Capacities: ❑FCR1(x2):>12"-24"field cut risers
35 GPM(2.2 L/s) /130.5 lbs.(59.2 kg) ❑CC1:membrane clamping collar kit(requires FCRI riser)
50 GPM(3.2 L/s) /127.6 lbs.(57.9 kg) ❑PPI:pumpout port kit
Solids Capacity:1.8 gal.(6.8 L) ❑SGK2:support gusset kit
Liquid Capacity:20 gal.(75.7 L)
Weight:49 lbs.(22.2 kg) ❑PLAIN-EA-24:2"(50 mm)plain end fitting
Connections:3"(75 mm)and 4"(100 mm)plain end ❑FPT-EA-34:4"x 3"(100 mm x 75 mm)FPT fitting
Cover bolted gas/water tight polypropylene with 1,000 Ib.load rating ❑FPT-EA-23:3"x 2"(75 mm x 50 mm)FPT fitting
when unit is buried with FCR1 riser
Approval
Signature: Date: Company:
Specifying Engineer: Engineering Firm:
10 JE MODEL NUMBER: DESCRIPTION:35/50 GPM Polyethylene Grease Interceptor
•
G B2
• PART#:4065-001-05 DWG BY:B.Karrer DATE:4/10/2019 REV: ECO:
Page 1 of 4
A SPECIAL . . .
For Schier
-Failure to follow this guidance
. . . . .
A WARNING! DO NOT AIR TEST UNIT OR RISER SYSTEM! CAUTION! Do not install this unit in any manner
Doing so may result in property damage,personal injury or death. except as described in these instructions.
Installation Instructions High Temperature Kitchen Water
Installation instructions and additional
installation
components are included with the instructions cold water supply line
interceptor.Read all instructions prior inside _-- high temperature effluent(>150°F)
to installation.This interceptor is approved backflow prevention assembly
intended to be installed by a licensed ---
DTV(drain water tempering valve)
plumber in conformance with all
local codes.
When Installing Interceptor Inside Interceptor
If your dishwashing sink(s) Interceptor
discharges into a floor
drain/sink(drain),you �� j •+s+yi
must regulate the flow into
the drain to avoid an directly connected indirectly connected
overflow of water onto the
kitchen floor.This can be Interceptor If water is entering the interceptor at excessive temperature(over
done by installing a valve Fernco or similar
or flow restriction ca rubber flow ► 150°F),a drain water tempering valve(DTV)and approved backflow
p on restriction end cap J prevention assembly must be installed.Most state and local
the sink piping that plumbing codes prohibit water above 150°F being discharged into
discharges into the drain. the sanitary sewer.Water above 150°F will weaken or deform PVC
See drawing for guidance.For detailed guidance on indirect Schedule 40 pipe,poly drainage fixtures like interceptors and erode
connections,go to: the coating of cast iron(leading to eventual failure).
webtools.schierproducts.com/Technical_Data/Indirect_connections.pdf
Hydrostatic Slabs(or Pressure Slabs)
ODOR ALERT!
Do not install air
When installed under a concrete slab subject to hydrostatic pressure gap on outlet side
hydrostatic slab(slab of interceptor.
designed to withstand
upward lift,usually
caused by hydrostatic
pressure)interceptor waterconcretetight
must be enclosed in a vault
watertight concrete vault.
0 MODEL NUMBER: DESCRIPTION:35/50 GPM Polyethylene Grease Interceptor
G B2
• PART#:4065-001-05 DWG BY:B.Karrer DATE:4/10/2019 REV: ECO:
Page 2 of 4
' SPECIAL PRECAUTIONS•
For Schier Grease Interceptor Installations-Failure to follow this guidance
voids
High Water Table Installations Fully Support Base of Unit
Interceptors and risers are not designed Install unit on solid,level surface in concrete floor
for direct burial p
to withstand water table heightin max water table height contact with the entire footprint of
excess of the top of the unit when buried unit base;for suspended
(see figure).If it is possible for this to17
nstallations design trapeze to Interceptor
occur,install the interceptor and risers in support the wet weight of the unit.
a water-tight concrete vault or backfill ��VInterceptor Do not partially support unit or
with concrete or flowable fill(wet suspend unit using metal
concrete and flowable backfill should be U-channel to create a trapeze.
poured in stages to avoid crushing the suspended installation
interceptor).At risk areas include but are not limited to tidal surge areas,
floodplains and areas that receive storm water.Great Basin'm models
that are direct buried in high water table scenarios must be installed Support Inlet and Outlet Piping
with an anchor kit.Models GB-50,GB-75,and GB-250 use model AKl
anchor kit.Model GB-500 uses model AK2 anchor kit for use with For above grade installations ensure pipe supports
deadmen anchors.Models GB-1000,GGI-750 and GGI-1500 use model heavy inlet and outlet piping(such as
AK3 anchor kit for use with deadmen anchors. cast iron or long runs)is properly
supported or suspended during the Interceptor
entire installation process to prevent
Flush-to-Grade Burials connection failure or damage to
Flush-to-Grade buried installations bulkhead fittings.
(without a riser)are not recommendedF7
for heavy foot traffic areas without the
use of an internal gusset support kit
SGK2(for G62)or SGK3(for GB3). DO NOT
COMPACT
BACKFILL
Interceptor
W MODEL NUMBER: DESCRIPTION:35/50 GPM Polyethylene Grease Interceptor
G B2
• .• PART#:4065-001-05 DWG BY:B.Karrer DATE:4/10/2019 REV: ECO:
...Mir.Mir. N.T.-FEEZ. -
Page 3 of 4
SPECIFICATIONS
Notes TOP VIEW
1. 4"FPT inlet/outlet with 3"and 4"plain end fittings.
2. Unit weight-49 lbs.(wet weight 216 lbs.)
3. Capacities- Liquid:20 gal. 35"
@35 GPM-Grease:130 lbs. 17.8 gal.
@50 GPM-Grease:127 lbs. 17.3 gal. outlet"A"
Solids:1.8 gal. L(Optional)
4. Built-in flow control.
5. For gravity drainage applications only.
6. Do not use for pressure applications. °o°o°Oo o°o
7. Cover placement allows full access to tank for
proper maintenance. Ao°°°°°o ® °°°°o°o° A
8. Vent not required unless per local code. 0 0 0 0 0 0
9. Engineered inlet and outlet diffusers are oo°°o°o
removable to inspect/clean piping. 23" o opo oe moo° 1
10.Inte Integral air relief anti-siphon. Inlets a o 0 0 0 o Outlet"B"
9 / p 000000 0000°00
(Standard)
Engineer Specification Guide °o°o°o°o o°o°o°o° Outlet toot
must face this
Schier Great BasinTm grease interceptor model #GB20 0 0 0°0 0 0°°°°° direction in all
shall be lifetime guaranteed and made in USA of o°o°0 0 0°0 oa - o° °o o configurations
seamless,rotationally-molded polyethylene.
Interceptor shall be furnished for above or below Outlet"C"
grade installation.Interceptor shall be certified to (optional) 12 7/16"
ASME A112.14.3(type C)and CSA B481.1,with field cut
riser system,built-in flow control and three outlet
options.Interceptor flow rate shall be 35 or 50 GPM.
Interceptor grease capacity shall be 130 lbs.@ 35
GPM or 127 lbs.@ 50 GPM.Cover shall provide
water/gas-tight seal and have minimum 450 lbs. SECTION A-A
load capacity.
Certified Performance q of 4"FPT See Note#10
Great BasinTm hydromechanical grease interceptors are inlet&outlet o 21-1/2"Cover
third party performance-tested and listed by IAPMO to
ASME#A112.14.3 and CSA B481.1 grease interceptor
standards and greatly exceed requirements for grease 5"
separation and storage.They are compliant to the
Uniform Plumbing Code,the National Standard 13-3/4'
Plumbing Code,the National Plumbing Code of Canada, i
and the International Plumbing Code. 8-3/4" 6-3/4"invert
UPC Engineered inlet Static water line
c ® and outlet diffuser
OUTLET END VIEW Rated Grease Capacites
�1 for Units Piped in Series
23 —{ No.of Units Removal Efficiency
in Series 97.8% 99%*
- I2 274lbs. 180 lbs.
NOTE:Flow rate for 2 GB2 units piped in
series is 35 GPM only
*Satisfies Miami DERM 99%
efficiency requirements
MODEL NUMBER: DESCRIPTION:35/50 GPM Polyethylene Grease Interceptor
GB2
PART#:4065-001-05 DWG BY:B.Karrer DATE:4/10/2019 REV: ECO:
Page 4 of 4
John ITEM#: QTY: y ��
BOOS MODEL#: JUN 1 ° Z02
Since 1887 PROJECT NAME: CITY OF IG
a DIVI N
zsa�as
"E3S8-201B" - 3 COMPARTMENT "E-SERIES" SINKS �•
WITH TWO DRAIN BOARDS AND GALVANIZED LEGS
FEATURES: CONSTRUCTION:
• 18GA STAINLESS STEEL TOP: STAINLESS STEEL SINKS ARE TIG WELDED,
• TYPE 300 STAINLESS STEEL WITH#4 POLISH, SATIN EXPOSED WELDS ARE POLISHED TO MATCH
FINISH ADJACENT SURFACE
• 12"AND T14"DEEP BOWLS BASE: GALVANIZED BASE
• ALL CORNERS, BOTH VERTICAL AND HORIZONTAL,
COVED AT 3/4"RADIUS MATERIAL:
• BOTTOMS OF BOWLS FORMED FOR DRAINAGE TO
3-1/2"DIAMETER DIE STAMPED OPENING BOWLS&TOP: 18GA TYPE 300 STAINLESS
• FULL LENGTH 10" HIGH BOXED BACKSPLASH,WITH STEEL WITH#4 POLISH, SATIN FINISH
2"RETURN TO WALL AT 45 DEGREE AND 1"TILE EDGE LEGS: 1-5/8"ROUND O.D. GALVANIZED STEEL
• 1" FAUCET HOLES IN BACKSPLASH GUSSETS: GALVANIZED STEEL
• ALL OUTSIDE CORNERS OF ASSEMBLY ARE BULLNOSED FEET: 1"ADJUSTABLE PLASTIC BULLET FEET
TO PROVIDE SAFE,CLEAN,AND POLISHED EDGE
• STANDARD STAINLESS STEEL LEGS 1-5/8" DIAMETER
• LEGS LOCATED DIRECTLY UNDER SINK BOWLS,
PROVIDING INCREASEDE STABILITY AND MAX WEIGHT
SUPPORT
YIIMMN
E
�N
E3S8-24-14
OFFICE COPY
10" DEEP - 3 COMP SINKS - 18GA 14" DEEP - 3 COMP SINKS - 18GA
13OWL SIZEcs
es L �•Ty • a a
R C
E3S8-1014-10T15 10" X 14"X 10" E3S8-15-14T15 15" X 15"X 14"
E3S8-1620-14T18 16"X 20" X 14"
12" DEEP - 3 COMP SINKS - 18GA E3S8-18-14T18 18" X 18" X 14"
:.
e E3S8-18-14T24 18"X 18"X 14"
R
E3S8-1620-12T18 16" X 20"X 12" E3S8-1824-14T24 18" X 24" X 14"
E3S8-18-12T18 18" X 18" X 12" E3S8-24-14T24' 24" X 24"X 14"
E3S8-1416-12-T12 14" X 16"X 12" E3S8-2030-14T24 20" X 30" X 14"
WITH TWO SETS OF FAUCET HOLES
146
"E3S8-2DB" - 3 COMPARTMENT "E-SERIES" SINKS
DETAILED SPECIFICATIONS
10" DEEP - SINK DIMENSIONS BOWL DIMENSIONS
i
n/4
12" 10" 10" 39- 10" X 14" 19-7/8" 14" 10"
12" DEEP - SINK DIMENSIONS 16" X 20" 25-1/2" 20" 12-15/16"
! 18" X 18" 23-1/2" 18" 11-15/16"
14-1/4" 12" 10" 43-3/4" 18" X 24" 29-1/2" 24" 14-15/16"
14" DEEP - SINK DIMENSIONS 24"X 24" 29-1/2" 24" 14-15/16"
!
16-1/4" 14" 10" 43-3/4"
1C
I I
fiI t
# f D H- SIZE O O O
35 1/4
I
i
r ICY
10" DEEP - 3 COMP SINKS - 18GA
E3S8-1014-10T15 10"X 14" X 10" 60"X 19-7/8" 15" 95
12" DEEP - 3 COMP SINKS - 18GA
rill 99!
E3S8-1620-12T18 16"X 20"X 12" 84"X 25-1/2" 18" 240
E3S8-18-12T18 18" X 18" X 12" 90"X 23-1/2" 18" 153
E3S8-1416-12-T12 14" X 16"X 12" 66" X 21-1/2" 12" 200
14" DEEP - 3 COMP SINKS - 18GA
E3S8-15-14T15 15"X 15"X 14" 75"X 20-1/2" 15" 231
E3S8-1620-14T18 16" X 20" X 14" 84" X 25-1/2" 18" 202
E3S8-18-14T18 18" X 18" X 14" 90" X 23-1/2" 18" 255
E3S8-18-14T24 18" X 18" X 14" 102" X 29-1/2" 24" 265
E3S8-1824-14T24 18" X 24" X 14" 104" X 29-1/2" 24" 288
E3S8-24-14T24` 24" X 24" X 14" 120" X 29-1/2" 24" 370
E3S8-2030-14T24 20" X 30"X 14" 108" X 35-1/2" 24" 291
'WITH TWO SETS OF FAUCET HOLES