Report RECEI 1) OFFICE COPY APR 2 8 2022 CITY OF TIGARb BUILDING DIVISION C. tt••l •:'•'♦. Sfrf t s S WYAT T FIRE PROTECTION, INC. 9095 S.V . Burnham Tigard, OR 97223 FPS2 222 GOO&S /n gi 3 sr/c/ &,JA'Jo /-,LL c11 ANNAND HILL TRIPLEXES 10847- 10895 SW ANNAND CT TIGARD, OR 97224 FIRE PROTECTION EQUIPMENT SUBMITTAL _ Worldwide www.tyco-fire.com ti,co Contacts RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe System . IMPORTANT The cover plate assembly conceals the sprinkler operating components . Refer to Technical Data Sheet above the ceiling.The flat profile of the TFP2300 for warnings pertaining to cover plate provides the optimum aes- regulatory and health information. thetically appealing sprinkler design. Always refer to Technical Data In addition, the concealed design of - r` Sheet TFP700 for the "INSTALLER the Series LFII Residential Concealed WARNING"that provides cautions Pendent Sprinklers provides 3/4" (19,1 with respect to handling and instal- mm) vertical adjustment. This adjust- lation of sprinkler systems and corn- ment provides a measure of flexibility )' ponents. Improper handling and when cutting fixed sprinkler drops. installation can permanently damage The Series LFII Residential Concealed a sprinkler system or its compo- Pendent Sprinklers are intended for use nents and cause the sprinkler to fail in the following scenarios: to operate in a fire situation or cause it to operate prematurely. • Wet pipe residential sprinkler sys- ' , tems for one and two family dwell- ings and mobile homes per NFPA Scan the OR code or enter the URL 13D in a web browser to access the most • Wet pipe residential sprinkler sys- up-to-date electronic version of this tems for residential occupancies up document. Data rates may apply. to and including four stories in height r •. ) 0 per NFPA 13R F . • �. • Wet pipe sprinkler systems for the NOTICE ■ - residential portions of any occu The Series LFII Residential Concealed '� T`' • pancy per NFPA 13 Pendent Sprinklers(TY2534)described $.41 I F The Series LFII Residential Concealed herein must be installed and main- • 1,k. Pendent Sprinklers have been designed tained in compliance with this docu- .• P. ■.�• with heat sensitivity and water distri- ment and with the applicable standards • bution characteristics proven to help of the NATIONAL FIRE PROTECTION 4111r. in the control of residential fires and to ASSOCIATION (NFPA), in addition to improve the chance for occupants to the standards of any authorities having �1 escape or be evacuated. jurisdiction.Failure to do so may impair ■ The Series LFII Residential Con- the performance of these devices. docs.jci.com/tycofire/ cealed Pendent Sprinklers (TY2534) The owner is responsible for main- rapid-response-4_9k are shipped with a Disposable Protec- taining their fire protection system tive Cap. The Protective Cap is tern- and devices in proper operating con- porarily removed for installation, and dition. Contact the installing contrac- General then it can be replaced to help protect tor or product manufacturer with any the sprinkler while the ceiling is being questions. . Description installed or finished.The tip of the Pro- tective Cap can also be used to mark Sprinkler The TYCO RAPID RESPONSE Series the center of the ceiling hole into the LFII Residential 4.9K Concealed plaster board, ceiling tiles, and so on, Identification Pendent Sprinklers (TY2534) are dec- by gently pushing the ceiling product orative, glass bulb sprinklers, avail- against the Protective Cap. When the Number (SIN) able in both ordinary 155°F(68°C)and ceiling installation is complete the Pro- intermediate 200°F (93°C) tempera- tective Cap is removed and the Cover TY2534 ture rated configurations. They are Plate Assembly is installed. designed for use in residential occu- pancies such as homes, apartments, dormitories,and hotels. Page 1 of 6 NOVEMBER 2021 TFP446 TFP446 Page 2 of 6 Technical SUPPORT FRAME CUP WITH (1/2" NPT) Data ROLL FORMED Mg THREADS Approvals e! =�� SPRINKLER UL and C-UL Listed WRENCH The TYCO RAPID RESPONSE Series LFII SEALING _I� FLATS Residential Concealed Pendent Sprinklers ASSEMBLY are Listed only when installed with LFII Con- cealed Cover Plates having factory-applied • finishes. BUTTON Sprinklers and Cover Plates are separately GUIDE ordered. See the Ordering Procedure PIN section for more information. BULB Maximum Working Pressure , rI. I r I1 [i 175 psi(12,1 bar) BRIDGE 1 BRIDGE Discharge Coefficient EJECTION K=4.9 GPM/psi'(70,6 LPM/bar'') SPRING COMPRESSION • Temperature Rating SCREW Ordinary DEFLECTOR 155°F(68°C)Sprinkler (OPERATED 139°F(59°C)Cover Plate DEFLECTOR POSITION) Note:Maximum Ambient Ceiling Tempera- turefortheordinarytemperatureconfigura- tion is 100°F(38°C). SPRINKLER Intermediate ASSEMBLY 200°F(93°C)Sprinkler THREAD INTO RETAINER 165°F(74°C)Cover Plate SUPPORT WITH THREAD Note:Maximum Ambient Ceiling Tempera- CUP UNTIL DIMPLES ture for the intermediate temperature con- MOUNTING A O figuration is 150°F(65°C). SURFACE IS '% i FLUSH WITH Vertical Adjustment CEILING EJECTION 3/4 in.(19,1 mm) SPRING Finishes �; U1 See the Ordering Procedure section Physical Characteristics SOLDER COVER PLATE COVER Frame Brass Support Cup Plated Steel TAB ASSEMBLY PLATE Guide Pins Stainless Steel FIGURE 1 Deflector Bronze RAPID RESPONSE SERIES LFII RESIDENTIAL Compression Screw Brass Glass Glass CONCEALED PENDENT SPRINKLER(TY2534) Button Phosphor Bronze Sealing Assembly..Beryllium Nickel w/TEFLON Cover Plate Brass Retainer Plated Steel Cover Plate Ejection Spring.... Stainless Steel Bridge Bronze Bridge Ejection Spring INCONEL Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector,supported by the Guide Pins, then drops down to its operated position. The glass bulb contains a fluid that expands when exposed to heat.When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb,activating the sprinkler and allowing water to flow. ANY TFP446 Page 3 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure2'3 • Maximum Maximum CoverageArea 9 .Rating Spacing 155°F(68°C),200°F(93°C) Minimum ft x ft ft Deflector to Installation Spacing (m x m) (m) Flow GPM Pressure Ceiling Type ft Psi (m) (LPM) (bar) 12 x 12 12 13 7.0 (3,7 x 3,7) (3,7) (49,2) (0,48) Smooth 1 Ceilings 14 x 14 14 13 7,0 3/8 to 1 1/8 in. (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed - 16 x 16 16 13 7.0 Ceilings per 8 (4,9 x 4,9) (4,9) (49,2) (0,48) NFPA 13D or Concealed (2,4) 13R,or 13. Installed in 18 x 18 18 17 12.0 beam (5,5 x 5,5) (5,5) (64,3) (0,83) 3/8 to 1 1/8 in. below bottom 20 x 20 20 20 16.7 of beam (6,1 x 6,1) (6,1) (75,7) (1,15) Notes: 1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.See Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications,the greater of 0.1 GPM/ft'over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER(TY2534) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA Design Criteria specified in NFPA 13D or NFPA 13R. Operational Sensitivity Design The sprinklers are to be installed rela- HydraulicThe TYCO RAPID RESPONSE Series (NFPA 13) stihoto ine Figureeg mounting surface as LFII Residential Concealed Pendent For systems designed to NFPA 13,the shown 2. Sprinklers (TY2534) are UL and C-UL number of design sprinklers is to be Sprinkler Spacing Listed for installation in accordance the four most hydraulically demanding The minimum spacing between sprin- with this section. sprinklers.The minimum required dis- klers is 8 ft (2,4 m). The maximum Note: When conditions exist that are charge from each of the four sprinklers spacing between sprinklers cannot outside the scope of the provided cri- is to be the greater of the following: exceed the length of the coverage area calcu- teria, refer to the Residential Sprinkler • The flow rates given in Table A as a (see Table A)being hydraulically Design Guide TFP490 for the manu- function of temperature rating and fated,for example,gem area, or 12 ft for a facturer's recommendations that may the maximum allowable coverage 12 20ft x 12 20f coverage area, . 20 ft for be acceptable to the authority having area a ft x ft coverage area. jurisdiction. The Series LFII must not be used • A minimum discharge of 0.1 GPM/ft2 in applications where the air ores- Ceiling Types over the design area comprised of sure above the ceiling is greater than Smooth flat horizontal, beamed, or the four most hydraulically demand- that below. Down drafts through the sloped in accordance with NFPA 13D, ing sprinklers for actual coverage Support Cup could delay sprinkler 13R,or 13 as applicable. areas protected by the four sprinklers operation in a fire situation. Hydraulic Design Obstruction to (NFPA 13D and 13R) Water Distribution For systems designed to NFPA 13D or Sprinklers are to be located in accor- NFPA 13R,the minimum required sprin- dance with the obstruction rules of kler flow rates are given in Table A as a NFPA 13D, 13R, and 13 as applicable function of temperature rating and the for residential sprinklers as well as with maximum allowable coverage areas. the obstruction criteria described within The sprinkler flow rate is the minimum the Technical Data Sheet TFP490. required discharge from each of the total number of "design sprinklers" as i r.rirrrrrr TFP446 Page 4 of 6 2-1/2" DIA. _ SPRINKLER- �(63,5 mm)� 3/4"(19,1 mm) FACE OF SUPPORT CUP THREADED SPRINKLER ASSEMBLY ADJUSTMENT FITTING / OPERATED t SPRINKLER �� 21/8"±3/8" lir �!' COVER 54 0 mm ;!' PLATE ( i RETAINER i' 3/324"GAP ±9,5 mm) I' _ 11--5 (2, mm) ..� 1 t \ M V } 1• % 9/16"(14,3 mm) r COVER- SPRINKLER- MOUNTING REPLACE AFTER "Mil • RETAINER SUPPORT CUPINSTALLATION / 1-5/16"(33,3 mm) ASSEMBLY ASSEMBLY 5/32" _ SURFACE / _.�! !�.__ (4,0 mm) 3 1/4" DIA. n DISPOSABLE DEFLECTOR IN (82,6 mm) Z„ PROTECTIVE CAP TIP OPERATED POSITION FIGURE 2 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER(TY2534) INSTALLATION DIMENSIONS,PROTECTIVE CAP,AND ACTIVATED DEFLECTOR Installation Note: Do not engage the sprinkler WRENCH frame arms by the wrench,engage only RECESS The TYCO RAPID RESPONSE Series the sprinkler wrench flats. I A L LFII Residential Concealed Pendent Step 4. Replace the Protective Cap by __ ' J Sprinklers (TY2534) must be installed pushing it upwards until it bottoms out �' in accordance with this section. against the Support Cup. The Protec- tive Cap helps prevent damage to the m General Instructions Deflector and Guide Pins during ceil- _ 0 Do not install any bulb type sprinkler ing installation and/or during applica- if the bulb is cracked or there is a loss tion of the finish coating of the ceiling. 1/2"SQUARE of liquid from the bulb, With the sprin DRIVE SOCKET It may also be used to locate the center kler held horizontally,a small air bubble of the clearance hole by gently pushing FIGURE 3 should be present. the ceiling material against the center W-TYPE 42 A 1/2 in. NPT sprinkler joint should be point of the Cap. SPRINKLER WRENCH obtained with a minimum to maximum Note: As long as the protective Cap torque of 7 to 14 lb-ft(9,5 to 19,0 the N remains in place, the system is consid- Higher levels of torque may distort the ered to be "Out Of Service." sprinkler inlet with consequent leakage or impairment of the sprinkler. Step 5. After the ceiling has been Do not attempt to compensate for completed with the 2 1/2 in. (63 mm) insufficient adjustment in the Cover diameter clearance hole and in prep Plate Assembly by under-or over- aration for installing the Cover Plate tightening the Sprinkler. Readjust the Assembly,remove and discard the Pro position of the sprinkler fitting to suit. tective Cap,and verify that the Deflec tor moves up and down freely. Step 1. The sprinkler must only be If the sprinkler has been damaged and installed in the pendent position and the Deflector does not move up and with the centerline of the sprinkler per down freely,replace the entire sprinkler pendicular to the mounting surface. assembly. Do not attempt to modify or Step 2. Remove the Protective Cap. repair a damaged sprinkler. Step 3. With pipe thread sealant Step 6. Push on the Cover Plate applied to the pipe threads and using Assembly until its flange comes in con- the W-Type 42 Wrench shown in Figure tact with the ceiling. 3, position the wrench recess to first Do not continue to push on the Cover straddle the deflector guide pins from Plate Assembly such that it lifts a the side and then push the wrench into the support cup to engage the sprin- panel out of its normal position. kler wrench flats. Rotate clockwise If the Cover Plate Assembly cannot to tighten the Sprinkler/Support Cup be engaged with the Mounting Cup Assembly into the fitting. The W-Type or the Cover Plate Assembly cannot 42 Wrench will accept a 1/2 in.ratchet be engaged sufficiently to contact the drive. ceiling, the Sprinkler Fitting must be repositioned. TFP446 Page 5 of 6 Care and Do not pull the Cover Plate relative to Limited the Enclosure.Separation may result. Maintenance Sprinklers which are found to be Warranty leaking or exhibiting visible signs of The TYCO RAPID RESPONSE Series corrosion must be replaced. For warranty terms and conditions,visit LFII Residential Concealed Pendent Automatic sprinklers must never be www.tyco-fire.com. Sprinklers (TY2534) must be main painted, plated, coated, or otherwise tained and serviced in accordance with OrderingModi- fled or over heated sprinklers must be Before closing a fire protection system replaced. Procedure main control valve for maintenance Care must be exercised to avoid avail- work on the fire protection system Contact your local distributor for which it controls, permission to shut damage before,during,and after instal- ability.When placing an order,indicate down the affected fire protection lation. Sprinklers damaged by drop- the full product name and part number • system must be obtained from the ping, striking, wrench twist/slippage, (P/N). authorities and allpersonnel or the like, must be replaced. proper Sprinkler Assemblies who may be affected by this action The owner is responsible for the Specify:Series LFII(TY2534)4.9K Res- must be notified. inspection,testing,and maintenance of idential Concealed Pendent Sprinkler, Absence of a Cover Plate may delay the their fire protection system and devices P/N(specify): sprinkler operation in a fire situation. in compliance with this document, as 155°F(68°C) 51-549-1-155 well as with the applicable standards 200°F(93°C) 51-549-1-200 When properly installed, there is an of the NATIONAL FIRE PROTECTION air gap between the lip of the Cover ASSOCIATION,for example, NFPA 25, Note: Sprinkler and Cover Plates are Plate and the ceiling. The Cover Plate in addition to the standards of any other separately sold. See below for Cover assembly has a nominal 3/32(2,4 mm) authorities having jurisdiction.Contact Plate ordering information. air gap, as shown in Figure 2. This air the installing contractor or product Cover Plate Assemblies gap is necessary for proper operation manufacturer with any questions. Specify: LFII Concealed Sprinkler of the sprinkler by allowing heat flow The owner must assure that the sprin- Cover Plate Assembly, temperature from a fire to pass below and above the klers are not used for hanging rating (specify), (specify) finish, P/N Cover Plate to help assure appropriate g g any ( p y) release of the Cover Plate in a fire situ- objects and that the sprinklers are only (specify): ation. If the ceiling is to be repainted cleaned by means of gently dusting 139°F(59°C) after the installation of the Sprinkler, with a feather duster; otherwise, non- Ivory(RAL1015) 56-891-0-135 care must be exercised to ensure that operation in the event of a fire or inad- Bright Chrome 56-891-9-135B vertent operation may result. Beige(RAL1001) 56-891-2-135 the new paint does not seal off any of Pure White(RAL9010)* 56-891-3-135 the air gap. Automatic sprinkler systems should be Signal White(RAL9003)** 56-891-4-135 Factory painted Cover Plates must not inspected,tested,and maintained by a Grey Brown(RAL8028)(RAL9002)) 56-891-5-135 56-891-6-135 be repainted.They should be replaced, qualified Inspection Service in accor Black(RAL9005) 56-891-7-135 if necessary, by factory painted dance with local requirements and/or Brushed Brass 56-891-8-135 units. Non factory applied paint may national codes. Brushed Chrome 56-891-9-135 adversely delay or prevent sprinkler Custom Paint 56-891-X-135 operation in the event of a fire. 165°F(74°C) Ivory(RAL1015) 56-891-0-165 Bright Chrome 56-891-9-165B Beige(RAL1001) 56-891-2-165 Pure White(RAL9010)" 56-891-3-165 Signal White(RAL9003)** 56-891-4-165 Grey White(RAL9002) 56-891-5-165 Brown(RAL8028) 58-891-6-165 Black(RAL9005) 56-891-7-165 Brushed Brass 56-891-8-165 Brushed Chrome 56-891-9-165 Custom Paint 56-891-X-165 " Eastern Hemisphere sales only "" Previously known as Bright White Note:All Custom Cover Plates are painted using SHERWIN-WILLIAMS Interior Latex Paint.Contact Johnson Controls Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 42 Sprinkler Wrench, P/N 56-000-1-079 TFP446 Page 6 of 6 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 0 2021 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks at National Fire Protection Association, TEFLON is a trademark of The Chemours Company FC,LLC,INCONEL Is a registered trademark of Special Metals Corporation, Controls SHERWIN-WILLIAMS is a registered trademark of SWIMC LW t111CU Worldwide www.tyco-fire.com Contacts Series RFII — 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General The Series RFII Sprinklers are shipped with a Disposable Protective Cap.The Description Protective Cap is temporarily removed p during installation and replaced to help """'``+ The TYCO Series RFII 5.6 K-factor, protect the sprinkler during ceiling "Royal Flush II" Concealed Pendent installation or finish.The tip of the Pro- Sprinklers Quick Response (3-mm tective Cap can be used to mark the bulb) and Standard Response (5-mm center of the ceiling hole into plaster bulb), are decorative sprinklers fea board or ceiling tiles by gently pushing turfing a flat cover plate designed to the ceiling product against the Pro- conceal the sprinkler.These sprinklers tective Cap. When ceiling installa are optimal for architecturally sensi tion is complete, the Protective Cap is tive areas such as hotel lobbies, office removed and the Cover Plate/Retainer buildings,churches,and restaurants. Assembly is installed. Each sprinkler includes a Cover Plate/ As an option,the Series RFII Standard Retainer Assembly and a Sprinkler/ Response(5-mm bulb)"Royal Flush II" Support Cup Assembly. The separa Concealed Pendent Sprinklers can be ble, two-piece assembly design pro fitted with a silicone Air and Dust Seal. Technical vides the following benefits: (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas Data • Allows installation of the sprinklers where it is desirable to prevent air and and pressure testing of the fire pro- dust from the area above the ceiling to Sprinkler Approvals tection system prior to installation of pass through the cover plate. Approvals apply only to the service a suspended ceiling or application of conditions indicated in the Design Criteria the finish coating to a fixed ceiling. NOTICE section. • Permits the removal of suspended The Series RFII Concealed Pendent • TY3531 (3 mm Bulb)is UL Listed,C-UL ceiling panels for access to building Sprinklers described herein must be Listed and NYC Approved(MEA 353- service equipment without having installed and maintained in compliance 01-E)as Quick Response. to first shut down the fire protection with this document and with the appli- • TY3531 (3 mm Bulb)is VdS Approved system and remove sprinklers. cable standards of the NATIONAL FIRE (Certificate No.G4090007). • Provides for 1/2 in.(12,7 mm)of ver- PROTECTION ASSOCIATION (NFPA), • TY3531 (3 mm Bulb)is FM and tical adjustment to allow a measure in addition to the standards of any LPCB Approved authorities having jurisdiction. Failure (Ref.No.094a/10)as of flexibility in determining the length Standard Response. to do so may impair the performance of fixed piping to cut for the sprinkler of these devices. Note:FM and LPCB do not approve drops. concealed sprinklers for quick The owner is responsible for maintain- response. ing their fire protection system and devices in proper operating condition. • TY3551 (5 mm Bulb)is UL Listed,C-UL The installing contractor or sprinkler Listed,FM Approved,LPCB Approved manufacturer should be contacted with (Ref.No.094a/9),and NYC Approved any questions. (MEA 353-01-E)as Standard Response. IMPORTANT Approvals for Air and Dust Seal Refer to Technical Data Sheet Sprinkler UL and C-UL Listed for use with the RFII TFP2300 for warnings pertaining to Standard Response Concealed Sprinkler regulatory and health information. Identification (TY3551) Always refer to Technical Data Maximum Working Pressure Sheet TFP700 for the "INSTALLER Number (SIN) Maximum andm 250 NY psi(17,3 bar)by UL, WARNING" that provides cautions with respect to handling and instal- TY3531 — 3 mm bulb Maximum 175 psi(12,1 bar)by FM,VdS, lation of sprinkler systems and com- TY3551 — 5 mm bulb and LPCB ponents. Improper handling and Temperature Rating installation can permanently damage 155°F(68°C)Sprinkler with a sprinkler system or its compo- 139°F(59°C)Cover Plate nents and cause the sprinkler to fail to operate in a fire situation or cause 200°F(93°C)Sprinkler with it to operate prematurely. 165°F(74°C)Cover Plate Page 1 of 4 SEPTEMBER 2018 TFP181 TFP181 Page 2 of 4 Discharge Coefficient 1/2"NPT SEALING K=5.6 GPM/psi1/2(80,6 LPM/bars/2) ASSEMBLY Adjustment 1/2 inch(12,7 mm) Finishes FRAME See the Ordering Procedure section CAP Physical Characteristics Frame Bronze Support Cup Plated Steel SUPPORT Guide Pins Stainless Steel CUP WITH BULB Deflector Bronze ROLL FORMED Compression Screw Brass THREADS Bulb Glass Cap Bronze or Copper r• Sealing Assembly..Beryllium Nickel w/TEFLON COMPRESSIONI I Cover Plate Brass SCREW Retainer Brass GUIDE Ejection Spring Stainless Steel PINS(2) ff Design L— , ` ' ' rj ,° DEFLEC(DROPTOR I I _ i POSITION) CriteriaED DEFLECTOR C.ti z_r The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent SPRINKLER/SUPPORT CUP Sprinklers are intended for fire protec- ASSEMBLY tion systems designed in accordance with the standard installation rules THREAD INTO i RETAINER recognized by the applicable Listing SUPPORT ) I WITH THREAD or Approval agency; for example, UL CUP UNTIL \ O O , DIMPLES Listing is based on NFPA 13 and VdS MOUNTING Approval is based on the CEA 4001. SURFACE IS EJECTION FLUSH WITH SPRING For more information on LPCB and VdS CEILING Approvals,contact Johnson Controlss at the following office: Enschede, Netherlands ��f_ �_ Telephone:31-53-428-4444 / Fax:31-53-428-3377 SOLDER J COVER The Series RFII Concealed Pendent TABS(3) COVER PLATE/RETAINER PLATE Sprinklers are only listed and approved ASSEMBLY with the Series RFII Concealed Cover FIGURE 1 Plates having a factory applied finish. MODEL RFII CONCEALED SPRINKLER ASSEMBLY NOTICE Do not use the Series RFII in applica- Installation Do not attempt to compensate for tions where the air pressure above the insufficient adjustment in the Sprinkler ceiling is greater than that below.Down The TYCO Series RFII 5.6 K-factor, by under-or over-tightening the Sprin- drafts through the Sprinkler/Support "Royal Flush II" Concealed Pendent kler/Support Cup Assembly.Re-adjust Cup Assembly can delay sprinkler Sprinklers must be installed in accor- the position of the sprinkler fitting to operation in a fire situation. dance with this section. suit. Step 1. Install the sprinkler only in the Operation General InstructionsDo not install any bulb-type sprinkler pendent position with the center-line if the bulb is cracked or there is a loss of the sprinkler perpendicular to the When exposed to heat from a fire, the of liquid from the bulb.With the sprin- mounting surface. Cover Plate, normally soldered to theq p Step 2. Remove the Protective Cap. Retainer at three points, falls away to kler held horizontally,a small air bubble expose the Sprinkler/Support Cup should be present.The diameter of the Step 3. With pipe thread sealant Assembly. air bubble is approximately 1/16 inch applied to the pipe threads, hand- (1,6 mm)for the 155°F(68°C)and 3/32 tighten the sprinkler into the sprinkler The Deflector — supported by the inch(2,4 mm)for the 200°F(93°C)tern- fitting. Guide Pins — then drops down to its perature ratings. Step 4. Wrench-tighten the sprinkler operational position. using only the RFII Sprinkler Wrench. A leak-tight 1/2 inch NPT sprinkler The glass bulb contains a fluid that joint should be obtained by applying a (Refer to Figure 3.) Apply the RFII expands when exposed to heat.When minimum to maximum torque of 7 to 14 Sprinkler Wrench to the Sprinkler as the rated temperature is reached, the ft.-lbs. (9,5 to 19,0 Nm). Higher levels shown in Figure 3. fluid expands sufficiently to shatter the of torque can distort the sprinkler Inlet glass bulb,activating the sprinkler and with consequent leakage or impairment allowing water to flow. of the sprinkler. TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE CLEARANCE SPRINKLER DIAMETER HOLE FITTING DIMENSION C J SPRINKLER ►=1. SUPPORT CUP ASSEMBLY I ;� r T— G 1/2"(12,7 mm) THREADED - �':'� D ADJUSTMENT i i FACE I•I-- OF CEILING, o RETAINING RING ""'• MOUNTING ( 1 SURFACE i l l DISPOSABLE PROTECTIVE CAP ; N\ - -I I ' 11" Step 5. Replace the Protective Cap by pushing it upwards until it bottoms L J out against the Support Cup. (Refer T to Figure 4.)The Protective Cap helps 3/16"to 11/16" MANUFACTURER DEFLECTOR COVER PLATE prevent damage to the Deflector and (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER Arms during ceiling installation and/or REFERENCE 3/32"(2,4 mm) POSITION ASSEMBLY finish.You can also use the Protective Cap to locate the center of the clear- COVER PLATE COVER PLATE ance hole by gently pushing the ceiling -PROFILE DEPTH DIAMETER material up against the center point of DIMENSION B DIMENSION A the Protective Cap. A:3-1/4 inches(82,6 mm) C:2-3/8 to 2-5/8 inches(60,3 to 66,7 mm) NOTICE B:3/16 inches(4,8 mm) D: 1-3/4 to 2-1/4 inches(44,5 to 57,2 mm) As long as the Protective Cap remains in place,the system is considered "Out FIGURE 2 of Service". SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Step 6. After the ceiling has been completed with the 2-1/2 in.(63,5 mm) diameter clearance hole and in prep- aration for installing the Cover Plate/ Retainer Assembly,remove and discard liiim FRAME l=l. the Protective Cap. Verify that the ,I ARM (% �_ %1: Deflector moves up and down freely. /' ��1' If the Sprinkler is damaged and the u I - ' - %/, Deflector does not move up and down SUPPORT / freely, replace the entire Sprinkler. - iCUP I - IjDo not attempt to modify or repair a �':'I I 1=11 ; damaged sprinkler. =_— = / Step 7. When installing an Air and I■I Dust Seal,refer to Figure 5; otherwise, ------- proceed to Step 8. To attach the Air 7/8"(23 mm) 0 and Dust Seal, verify the angle of the SQUARE outside edge of the seal is oriented according to Figure 5.Start the edge of _ the Retainer in the grooved slot of the ALIGN �J Air and Dust Seal and continue around ARROWS WITH ` the retainer until the entire Air and Dust - FRAME ARMS \\_ Seal is engaged. -\ a rl ACCEPTS 0 1/2"SOCKET \ ,-r DRIVE FIGURE 3 RFII SPRINKLER WRENCH TFP181 Page 4 of 4 Step 8. Screw on the Cover Plate/ SUPPORT - SPRINKLER FACE OF ORIENT Retainer Assembly until the Retainer CUP CEILING SEAL (shown in Figure 2)or the Air and Dust BEVEL AS Seal (shown in Figure 5) contacts the j'/� ceiling.Do not continue to screw on the j=�� 1 COVER SHOWN Cover Plate/Retainer Assemblyso that PLATE it lifts a ceiling panel out of its normal ` l , RETAINER - position. If you cannot engage the 1111111 ,►f ASSEMBLY r Cover Plate/Retainer Assembly with KAN :� 0 the Support Cup or you cannot engage Ithe Cover Plate/Retainer Assembly suf ficientl to contact the ceilin ou must ►,'��� AIR repositon the Sprinkler Fittng /� •'■'• ;!,����� ��/ AND DUST � 11- `=- -- SEAL m.--- ------• �II LIP OF COVER Care and RETAINER PLATE FIGURE 5 Maintenance OPTIONAL AIR AND DUST SEAL FOR SERIES RFII(TY3551) The TYCO Series RFII 5.6 K-factor, Care must be exercised to avoid "Royal Flush II" Concealed Pendent damage to the sprinklers before, Ordering Sprinklers must be maintained and during, and after installation. Sprin- serviced in accordance with this klers damaged by dropping, striking, Procedure section. wrench twist/slippage,or the like,must Before closing a fire protection system be replaced. Also, replace any sprin- Contact yourW local distributor for main control valve for maintenance kler that has a cracked bulb or that has availability.ttWhen placingt a an order, work on the fire protection system lost liquid from its bulb. (Ref. Installa- that the full product name. that it controls, obtain permission to tion Section.) Sprinkler/Support Cup Assembly shut down the affected fire protection Exercise care to avoid damage to sprin Specify: Series RFII (specify SIN), system from the proper authorities klers before, during, and after instal K=5.6, "Royal Flush II"Pendent Sprin- and notify all personnel who may be lation. Replace sprinklers damaged klers(specify)temperature rating,P/N* affected by this action. by dropping, striking, wrench twist- (specify): Absence of the Cover Plate/Retainer ing, wrench slipping, or the like. Also, 155°F(68°C) 200°F(93°C) Assembly can delay sprinkler opera- replace any sprinkler that has a cracked TY3531 51-792-1-155 51-792-1-200 tion in a fire situation. bulb or that has lost liquid from its bulb. TY3551 51-790-1-155 51-790-1-200 (Refer to the Installation section.) When properly installed, there is a • Use Suffix"I"for ISO 7-1 connection;for example. nominal 3/32 in. (2,4 mm) air gap If you must remove a sprinkler, do not 51-792-1-155-I between the lip of the Cover Plate and reinstall it or a replacement without Separately Ordered Cover Plate/ the ceiling, as shown in Figure 2. reinstalling the Cover Plate/Retainer Retainer Assembly: Assembly. If a Cover Plate/Retainer Specify: (temperature ratingfrom This air gap is necessary for proper Assembly becomes dislodged during p y: ( p operation of the sprinkler. If the ceiling service,replace it immediately. below) Series RFII Concealed Cover requires repainting after sprinkler Plate with(finish), P/N (specify). installation, ensure that the new paint The owner is responsible for the 139°F(59°C)(a) 165°F(74°C)(b) does not seal off any of the air gap. inspection,testing,and maintenance of Grey White their fire protection system and devices (RAL9002) 56-792-0-135 56-792-0-165 Do not pull the Cover Plate relative to in compliance with this document, as Brass 56-792-1-135 56-792-1-165 the Enclosure.Separation may result. well as with the applicable standards Pure White(c) are found to of the NATIONAL FIRE PROTECTION (RAL9010) 56-792-3-135 56-792-3-165 Sprinklersking whichhicing visible signs bef ASSOCIATION,for example, NFPA 25, Signal White leaking or n must be replaced. in addition to the standards of any other (RAL9003) 56-792-4-135 56-792-4-165 corrosiauthorities having jurisdiction.Contact Jet Black Automatic sprinklers must never be the installing contractor or sprinkler (RAL9005) 56-792-6-135 59-792-6-165 painted, plated, coated, or other- manufacturer regarding any questions. Brushed Chrome 56-792-8-135 56-792-8-165 wise altered after leaving the factory. Automatic sprinkler systems should be Chrome 56-792-9-135 56-792-9-165 Modified sprinklers must be replaced. inspected,tested,and maintained by a custom 56-792-X-135 56-792-X-165 Sprinklers that have been exposed to qualified Inspection Service in accor- corrosive products of combustion, but dance with local requirements and/or (a) For use with 155°F(68°C)sprinklers. have not operated,should be replaced national code. (b) For use with 200°F(93°C)sprinklers. if they cannot be completely cleaned (c) Eastern Hemisphere sales only. by wiping the sprinkler with a cloth or Limited Sprinkler Wrench by brushing it with a soft bristle brush. p Specify: RFII Sprinkler Wrench, Warranty P/N 56-000-1-075 For warranty terms and conditions,visit Air and Dust Seal www.tyco-fire.com. Specify:Air and Dust Seal, P/N 56-908-1-001 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 '�/'� ®2018 Johnson Controls.All rights reserved.All specifications and other inform t Is I s 1 � information shown were current as of document revision date and are subject to change without notice. Johnson , NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association, Controls strols TEFLON is a registered trademark of DuPont tLICQ Fire & Building Products rapid response HOME FIRE SPRINKLER SYSTEM Technical Services:Tel: (800)381-9312/Fax: (800)791-5500 BlazeMaster ® CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Technical Description Data Tyco Fire & Building Products (TFBP) Sizes BlazeMaster CPVC Pipe and Fittings 3/4'to 3 are designed exclusively for use in wet Maximum Working Pressure pipe automatic fire sprinkler systems. ' t They are made from a specially devel- 175 psi oped thermoplastic compound corn- Approvals posed of post chlorinated polyvinyl UL, FM, CUL, NSF, Dade County, - � chloride(CPVC)resin and state of the LPCB,MEA,and the City of Los Ange- art additives. TFBP BlazeMaster les. (Refer to IH-1900, Rev. 0, Janu- ,~ CPVC products are easier to install ary 2005 "Installation Instruction & q { than traditional steel pipe systems, Technical Handbook" for exact list- and at the same time,provide superior ing/approval information.) ' ( , heat resistance and strength as corn- Manufacture Source pared to traditional CPVC and PVC U.S.A. piping materials used in the plumbing trade. Various adapters are available Material to connect CPVC pipe to metallic pip- ing. All female pipe thread adapters have brass inserts for durability. • Fittings: ASTM F438 (Sch. 40) and Grooved adapters connect directly to ASTM F439(Sch.80),ASTM F1970 grooved end valves and metallic pipe, with flexible grooved end couplings. Color Orange WARNING Tyco Fire& Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. BlazeMastero is a registered trademark of Noveon IP Holding Corp. Page 1 of 6 JANUARY, 2006 TFP1915 Page 2 of 6 TFP1915 NOMINAL AVERAGE AVERAGE WEIGHT WATER FILLED WEIGHT FT.OF PIPE WEIGHT PER LIFT SIZE O.D. I.D. lbs./ft. PER LIFT lbs. lbs./ft. 3/4" 1.050" 0.874" 0.18 0.44 7875 1339 1" 1.315" 1.101' 0.26 0.67 5040 1320 1-1/4" 1.660" 1.394" 0.42 1.08 2835 1191 1-1/2" 1.900" 1.598" 0.54 1.41 2205 1213 2" 2.375" 2.003" 0.84 2.20 1260 1084 2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531 3" 3.500" 2.952" 1.87 4.83 720 1344 i FIGURE 1—PIPE DIMENSIONS • Installation Care and Tyco Fire and Building Products Maintenance (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- The owner is responsible for the fin- ance with IH-1900, Rev. 0, January spection, testing, and maintenance of 2005"Installation Instruction&Techni- their fire protection system and de- cal Handbook". vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls,permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service,notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. TFP1915 Page 3 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (T/O) (lb.) TEE 80000 3/4" 5/8" 40 0.11 /MMp 1/0 80001 1" 11/16" 40 0.19 j 80002 1-1/4" 7/8" 40 0.26 Mi`M 80003 1-1/2" 1-1/16" 80 0.51 1111.EM 80004 2" 1-3/8" 80 0.90 ormrJAPIISIrdilwrAmm 80005 2-1/2" 1-9/16" 80 1.59 T/0 .1. T/O 80006 3" 1-13/16" 80 2.41 - XxYxZ X Y Z 80132 3/4"x 3/4"x 1" 3/4" 3/4" 5/8" 40 0.14 • 80133 1"x 3/4"x 3/4" 9/16" 9/16" 3/4" 40 0.14 80134 1"x 3/4"x 1" 3/4" 11/16" 3/4" 40 0.17 80260 1"x 1"x 3/4" 5/8" 5/8" 13/16" 40 0.16 80135 1-1/4"x 1"x 3/4" 5/8" 5/8" 15/16" 40 0.21 80136 1-1/4"x 1"x 1" 3/4" 3/4" 15/16" 40 0.22 80137 1-1/4"x 1"x 1-1/4" 15/16" 15/16" 7/8" 40 0.26 REDUCING TEE 80261 1-1/4"x 1-1/4"x 3/4" 5/8" 5/8" 7/8" 40 0.23 80262 1-1/4"x 1-1/4"x 1" 3/4" 3/4" 7/8" 40 0.26 Z 80138 1-1/4"x 1-1/4"x 1-1/2" 1" 1" 1" 80 0.43 I.1111110 MMO T/O 80140 1-1/2"x 1-1/4"x 3/4" 9/16" 9/16" 1" 80 0.36 .ii�. 80141 1-1/2"x 1-1/4"x l" 9/16" 9/16" 1-1/16" 80 0.38 80263 1-1/2"x 1-1/2"x 3/4" 9/16" 9/16" 1" 80 0.36 X MIMI.Y ( 80264 1-1/2"x 1-1/2"x 1" 9/16" 9/16" 1-1/16" 80 0.38 a�JJ'�� 80275 1-1/2"x 1-1/2"x 1-1/4" 7/8" 7/8" 1" 80 0.45 T10 •• T/O 80265 2"x 2"x 3/4" 3/4" 3/4" 1-3/8" 80 0.61 80266 2"x 2"x 1" 7/8" 7/8" 1-3/8" 80 0.66 80274 2"x 2"x 1-1/4" 1-1/16" 1-1/16" 1-3/8" 80 0.74 80267 2"x 2"x 1-1/2" 1-1/8" 1-1/8" 1-3/8" 80 0.78 80271 2-1/2"x 2-1/2"x 1" 1-9/16" 1-9/16" 1-9/16" 80 1.43 80272 2-1/2"x 2-1/2"x 1-1/4" 1-9/16" 1-9/16" 1-9/16" 80 1.46 80273 2-1/2"x 2-1/2"x 1-1/2" 1-9/16" 1-9/16" 1-9/16" 80 1.48 80276 2-1/2"x 2-1/2"x 2" 1-9/16" 1-9/16" 1-9/16" 80 1.50 80270 3"x 3"x 1-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.28 80268 3"x 3"x 2" 1-13/16" 1-13/16" 1-3/4" 80 2.25 80269 3"x 3"x 2-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.44 CROSS&REDUCING CROSS 80009 3/4" 9/16" 40 0.13 Milk- T/O 80010 1" 11/16" 40 0.23 80011 1-1/4" 15/16" 40 0.34 MINI=■ 80012 1-1/2" 1-1/16" 80 0.67 M'!M■ 80013 2" 1-5/16" 80 1.00 1�r 80014 2-1/2" 1-9/16" 80 1.91 IIMMII T/O 80008 3" 1-13/16" 80 2.89 T/O ■■ T/O 80015 1"x 1"x 3/4"x 3/4" 7/8" 40 0.28 80025 3/4" 5/8" 40 0.09 90°ELBOW& REDUCING ELBOW 80026 1" 3/4" 40 0.14 80027 1-1/4" 7/8" 40 0.21 X 80028 1-1/2" 1-1/16" 80 0.40 /..j T/0 80029 2" 1-5/16" 80 0.79 80030 2-1/2" 1-9/16" 80 1.14 MM 80031 3" 1-13/16" 80 1.82 WIIIIIIIYt XxY X Y -T/O 80032 1"x 3/4" 11116" 13/16" 40 0.16 FIGURE 2-FITTING DIMENSIONS(Part 1 of 4) Page 4 of 6 TFP1915 FITTING PART NOMINAL TAKE-OUT WEIGHT TYPE NUMBER NOMINAL SIZE SCHD.(T/O) (lb.) 45°ELBOW 80050 3/4" 3/8" 40 0.08 T/O - 80051 1" 3/8" 40 0.11 4� 80052 1-1/4" 3/4" 40 0.20 ''r�'' 80053 1-1/2" 1/2" 80 0.31 T/O ��S . 80054 2" 3/4" 80 0.56 �i�� 80055 2-1/2" 13/16" 80 0.89 80056 3" 1" 80 1.19 80075 3/4" 1/8" 40 0.07 COUPLING& 80076 1" 1/8" 40 0.11 REDUCING COUPLING 80077 1-1/4" 3/16" 40 0.12 1-1/2" 3/16" 80 0.25 I_lI80078 80079 2" 3/16" 80 0.38 80080 2-1/2" 1/4" 80 0.67 -T/O 80081 3" 3/16" 80 0.91 80220 1"x 3/4" 1/8" 40 0.08 80200 1"x 3/4" 7/16" 40 0.04 80201 1-1/4"x 3/4" 1/2" 40 0.11 80202 1-1/4"x 1" 5/16" 40 0.12 80203 1-1/2"x 3/4" 5/8" 80 0.16 80204 1-1/2"x 1" 1/2" 80 0.14 REDUCER BUSHING 80205 1-1/2"x 1-1/4" 3/8" 80 0.17 80206 2"x 3/4" 13/16" 80 0.27 I.jj 80207 2"x 1" 11/16" 80 0.26 80208 2"x 1-1/4" 9/16" 80 0.24 80209 2"x 1-1/2" 7/16" 80 0.19 -T/O 80215 2-1/2"x 1" 15/16" 80 0.42 80214 2-1/2"x 1-1/4" 13/16" 80 0.45 80213 2-1/2"x 1-1/2" 11/16" 80 0.46 80211 2-1/2"x 2" 5/8" 80 0.29 80210 3"x 2" 3/4" 80 0.72 80212 3"x 2-1/2" 1/2" 80 0.47 CAP 80100 3/4" 5/16" 40 0.04 80101 1" 3/8" 40 0.06 80102 1-1/4" 7/16" 40 0.10 80103 1-1/2" 11/16" 80 0.20 80104 2" 5/8" 80 0.31 T/O-i I- 80105 2-1/2" 7/8" 80 0.58 80106 3" 1" 80 0.88 GROOVED T/O PIPE O.D. COUPLING ADAPTER • 80160 1-1/4"x 1-1/4"Groove 2-5/16" 1-1/4"(1.660") 40 0.78 It:��u N 80161 1-1/2"x 1-1/2"Groove 2-5/16" 1-1/2"(1.900") 80 0.95 PIPE 80162 2"x 2"Groove 2-5/16" 2"(2.375") 80 1.42 O.D. ` 80163 2-1/2"x 2-1/2"Groove 2-5/16" 2-1/2"(2.875") 80 2.28 80164 3"x 3"Groove 2-1/4" 3"(3.500") 80 3.00 -T/O-I 80169 2-1/2"x 76,1 mm Groove 2-5/16" 76,1 mm(3.000") 80 2.28 FIGURE 2-FITTING DIMENSIONS(Part 2 of 4) TFP1915 Page 5 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (T/O) (lb.) SPRINKLER HEAD ADAPTER 80175E 3/4"x 1/2"NPT 7/16" 80 0.20 80176E 1"x 1/2"NPT 7/16" 80 0.22 80175WL 3/4"x 1/2"NPT 7/16" 40 0.16 80179 1"x 3/4"NPT 13/16" 40 0.43 T/O SPRINKLER HEAD ADAPTER v �" 80175W 3/4"x 1/2"NPT 1/2" 40 0.19 • IIIIl 80176W 1"x 1/2"NPT 1/2" 40 0 18 _a .. T/O SPRINKLER HEAD ADAPTER(SPIGOT) P� 80177L 3/4"x 1/2"NPT 1/2" 40 0.16 80178 1"x 1/2"NPT 9/16" 40 0.20 '- `1 ! 80180 1"x 3/4"NPT 7/8" 40 0.40 -1 T/O FEMALE ADAPTER 80142 3/4"x 3/4"NPT 13/16" 40 0.41 11111 80145 1'x 1"NPT 7/8" 40 0.63 80146 1-1/4"x 1-1/4"NPT 1-1/8" 40 1.03 80147 1-1/2"x 1-1/2"NPT 1-3/8" 80 1.42 wAr���i\\\\\ 80148 2"x 2"NPT 1-11/16" 80 266 -T/O MALE ADAPTER rilin 80158 3/4" 1N x 3/4" T 1-5/16" 40 0.56 1 80158 1'x 1"NPT 1-3/8" 40 0.56 -T/O- XxYxZ X Y Z SPRINKLER HEAD ADAPTER TEE 80250 3/4"x 3/4"x 1/2"NPT 9/16" 9/16" 1" 40 0.22 Z 80251 1"x 1"x 1/2"NPT 11/16" 11/16" 1-3/16" 40 0.29 T/O 80249 1"x 1"x 1"NPT 15/16" 15/16" 1-9/16" 40 0.73 PR 80256 1-1/4"x 1"x 1/2"NPT 7/16" 9/16" 1-5/16" 40 0.30 -MI= 80252 1-1/4"x 1-1/4"x 1/2"NPT 7/16" 7/16" 1-5/16" 40 0.31 X MEI=Y ) 80257 1-1/2"x 1-1/4"x 1/2"NPT 1/2" 11/16" 1-7/16" 80 0.43 Awmr ���i��. 80254 1-1/2"x 1-1/2"x 1/2"NPT 1/2" 1/2" 1-7/16" 80 0.46 T/O •• T/O 80258 2"x 1-1/2"x 1/2"NPT 1/2" 5/8" 1-11/16" 80 0.56 80253 2"x 2"x 1/2"NPT 1/2" 1/2" 1-11/16" 80 0.62 FIGURE 2—FITTING DIMENSIONS(Part 3 of 4) Page 6 of 6 TFP1915 FITTING PART NOMINAL TAKE-OUT WEIGHT TYPE NUMBER NOMINAL SIZE SCHD.(T/O) (lb.) BACK-TO-BACK TEE X x Y x Z X Y,Z X 1111 T/O Y iii �M 80459 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.48 IIIIII�'��IIIIII MIItM,t=Illii z 1 80460 1"x 1/2"NPT x 1/2"NPT 5/8" 1-3/16" 40 0.46 T/O -- T/O BACK-TO-BACK CROSS X x Y x Z x W X,Y Z,W X !1L T/O Z.:w/ 1111 ms m6111111 80462 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-3/16" 40 0.46 I/O /„� ` 80463 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.47 T/O T/O SPRINKLER HEAD X x Y X Y ADAPTER 90°ELBOW Y �"`I I/O I���l 80199 3/4"x 1/2"NPT 9/16" 1" 40 0.20 • 80198 1"x 1/2"NPT 3/4" 1-1/4" 40 0.26 ���I'-X 80196 1"x 3/4"NPT 1-1/16" 1-7/16" 40 0.26 —T/O FIGURE 2—FITTING DIMENSIONS(Part 4 of 4) by TFBP to be defective shall be either of merchantability and fitness for a oar- Limited repaired or replaced, at TFBP's sole ticular ouroose. Warranty option. TFBP neither assumes, nor This limited warranty sets forth the ex- authorizes any person to assume for it, clusive remedy for claims based on any other obligation in connection with failure of or defect in products, materi- Products manufactured by Tyco Fire& the sale of products or parts of prod- Building Products (TFBP) are war- ucts.TFBP shall not be responsible for als or components, whether the claim ranted solely to the original Buyer for sprinkler system design errors or inac- is made in contract, tort, strict liability ten(10)years against defects in mate- curate or incomplete information sup- or any other legal theory. rial and workmanship when paid for plied by Buyer or Buyer's repre- This warranty will apply to the full ex- and properly installed and maintained sentatives. tent permitted by law.The invalidity,in under normal use and service. This whole or part, of any portion of this • warranty will expire ten (10) years In no event shall TFBP be liable, in warranty will not affect the remainder. from date of shipment by TFBP. No contract, tort, strict liability or under warranty is given for products or com- any other legal theory, for incidental, ponents manufactured by companies indirect,special or consequential dam- not affiliated by ownership with TFBP ages, including but not limited to labor or for products and components which charges, regardless of whether TFBP have been subject to misuse,improper was informed about the possibility of installation, corrosion, or which have such damages, and in no event shall not been installed, maintained, modi- TFBP's liability exceed an amount fied or repaired in accordance with ap- to the sales price. plicable Standards of the National Fire The foregoing warranty is made in lieu Protection Association, and/or the of any and all other warranties. ex- standards of any other Authorities press or implied. including warranties Having Jurisdiction. Materials found TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS NOMINAL PIPE SIZE (in) WEIGHT (Ibslft) I.D. (in) BUNDLE SIZE 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS • NOMINAL PIPE SIZE (in) SCHEDULE 40 EDDYTHREAD 40 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems n, 1819 Clarkson Road For additional information, C �` us (��vU Chesterfield,MO 63017 contact your salesperson today at J BULL MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 (� LISTED�J FAX: (636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 41> A COOK)company e-mail:sales(n)bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 ES-A-2000B Series 2000B A M E S Double Check Valve Assemblies FIRE&WATERWORKS Sizes: 1/2" -2" (15-50mm) Features • Ease of maintenance with only one cover 2"2000B HC • Top entry (50mm) • Replaceable seats and seat discs • Modular construction • Compact design uk • 1/2"—2" (15—50mm)Cast bronze body construction • • Top mounted ball valve test cocks 3/a"20006 • Low pressure drop (20mm) • No special tools required Series 2000B Double Check Valve Assemblies are designed to protect drinking water sup- • 1/2"—1" (15—25 mm)have plies for dangerous cross-connections in accordance with national plumbing codes and tee handles water authority requirements for non-health-hazard non-potable service applications such as irrigation,fire line,or industrial processing. Available Models These valves meet the requirements of ASSE Std. 1015 and AWWA Std.C510 and are Suffix: approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. B- Quarter turn ball valves LBV- less ball valves Specifications SH- stainless steel ball valve handles A Double Check Valve Assembly shall be installed at each noted location.The assembly HC- 21/2" inlet/outlet fire hydrant fitting shall consist of two positive seating check modules with captured springs and rubber seat (2"valve) discs.The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. Pressure — Temperature The assembly shall also include two resilient seated isolation valves and four top mounted, Temperature Range:33°F—140°F resilient seated test cocks.The assembly shall meet the requirements of ASSE Std. 1015 (0.5°C—60°C) and AWWA Std.C510.Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California.Assembly shall be an Ames Maximum Working Pressure: 175psi Company Series 2000B. (12.1 bar) Approvals Standards ��pss'F'Fo AWWA Std.C510, IAPMO PS31 41) Sp® O OW US c us 1015 864.5 '/a"-2" A WARNING (LBV Models Only) It is illegal to use this product in any plumbing Approved by the Foundation for Cross-Connection Control and Hydraulic Research at system providing water for human consumption, the University of Southern California. such as drinking or dishwashing,in the United LBV models not listed. States.Before installing standard material prod Horizontal and vertical "flow up"approval on all sizes. uct,consult your local water authority,building pp and plumbing codes. Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. Approval Representative Ames product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. amesfirewater.com Dimensions - Weights A �� M . ! • t rt/ 1.am. ':.' ... Z.1 111111n11WIE ,,.�M _ J ._Nma-■u B l o r �illikl )1� F * �`` Suffix HC -Fire Hydrant Fittings dimension"A"=231/2"(594mm) �_H`�-lam G SIZE(ON) DIMENSIONS WEIGHT A B C F G H I in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 1/2 15 10 254 45/s 117 21/26 62 5 127 33/s 85 25/6 59 21/26 52 4.5 2 • % 20 111/s 282 4 102 3% 79 6%6 157 31/6 87 2% 54 15/6 33 5 2.3 1 25 1314 337 5% 130 4 102 71/2 191 33/s 85 11/6 43 111/26 43 12 5.4 11/4 32 16% 416 5 127 35/6 84 912 241 5 127 3 76 2 50 15 6.8 112 40 163/4 425 4'/s 124 3'h 89 93/4 248 513/is 148 3% 79 211/26 68 15.86 7.2 2 50 191/2 495 61/4 159 4 102 133/s 340 6% 156 37As 87 211A6 68 25.75 11.7 Strainer sold separately Capacities kPa psi A 11/411 (32mm) As compiled from documented Foundation for Cross-Connection Control 96 14 and Hydraulic Research at the University of Southern California lab tests. y 83 12 ATypical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) 0 69 10 55 8 kPa psi 1/2"(15mm) = 41 6 , y 83 12 A m 28 4 �- O 69 10 i 14 2 55 8 a • 41 6 - 1r -^ 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 4U) 14 2 AP 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm a` 0 0 5 7.5 10 15 fps 0 2 4 6 8 10 12 gpm 1.5 2.3 3.0 4.6 mps AP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm Flow Rate 5 7.5 10 fps 1.5 2.3 3.0 mps kPa psi 1 f/211(40mm) Flow Rate 83 12 kPa psi A 3/411 (20mm) in 69 69 10 a 152 22 0 55 8 a-1 124 18 j 28 4 i 96 14 2 14 2 2 69 10 0 0 IL• 41 6 _�� 12a Apo 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 14 2 �� 5 7.5 10 15 fps 0 5 10 15 26 25 30 35 40 45 50 gpm 1.5 2.3 3.0 4.6 mps AP 0 19 33 57 76 9i 114 133 152 171 190Ipm Flow Rate 7.5 15 fps 2.3 4.6 mps kPa psi 2° (50mm) Flow Rate to83 12 A kPa psi II .869 10 y 110 16 A 1 (25mm) J 55 8 _1• 83 12 a 41 6 y 69 10 55 8 28 4 14 2 H 41 6 a 0 0 28 4 __,..... - a 14 2 - 0 25 50 75 100 125 150 175 200 gpm AP 0 95 190 285 380 475 570 665 760 Ipm 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 5 7.5 10 15 fps AP 0 19 38 57 76 95 114 133 152 171 190 209 228 1pm 1.5 2.3 3.0 4.6 mps 5 7.5 10 15 fps Flow Rate 1.5 2.3 3.0 4.6 mps AFlow Rate A M E S FIRE&WATERWORKS A Watts Water Technologies Company USA:Backflow Tel:(978)689-6066•Fax:(978)975-8350•AmesFireWater.com USA:Control Valves Tel:(713)943-0688•Fax:(713)944-9445•AmesFireWater.com Canada: Tel:(905)332-4090•Fax:(905)332-7068•AmesFireWater.ca Latin America: Tel:(52)81-1001-8600•Fax:(52)81-8000-7091 •AmesFireWater.com ES-A-2000B 1410 ©2014 Ames Fire&Waterworks P POTTER FOR SMALL PIPE VSR-S VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,ULC,CSFM Listed and NYMEA Accepted Service Pressure: Up to 300 PSI(20,7 BAR) Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM)UL Maximum Surge: 18 FPS(5,5 m/s) Enclosure: Die-cast,red enamel finish Cover held in place with tamper resistant screws Contact Ratings: Two sets of SPDT(Form C) 10.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Resistive 10mAmps min.at 24 VDC Conduit Entrances:Two openings provided for 1/2"conduit. S Individual switch compartments suitable for dissimilar voltages. Usage: Listed plastic,copper and schedule 40 iron pipe. Fits pipe sizes-1"(25mm),1 1/4"(32mm), 1 1/2"(38mm) and 2"(50mm) Stock No. 1144440 Note:12 paddles are furnished with each unit,one for each pipe size of threaded and sweat TEE,one for 1"(25mm)CPVC, one for 1"(25mm)CPVC(Central),one for 1"threaded Nibco CPVC,and one for 1 1/2"(38mm)threaded(Japan). Environmental Specifications: • NEMA-4/IP54 Rated enclosure suitable for indoor or outdoor Installation must be perfomed by qualified personnel and in use with factory installed gasket and die-cast housing when used accordance with all national and local codes and ordinances. with appropriate conduit fitting. Shock hazard. Disconnect power source before servicing. • Temperature range:40°F to 120°F,(4,5°C to 49°C)UL Serious injury or death could result. Service Use: Risk of explosion. Not for use in hazardous locations. Serious Automatic Sprinkler NFPA-13 injury or death could result. One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional:Cover Tamper Switch Kit,Stock No.0090148 (See Fig.7 for terminations) Replaceable Components:Retard/Switch Assembly,stock no. 1029030 The Model VSR-S is a vane type waterfiow switch for use on wet Installation sprinkler systems that use 1"(25mm), 1%"(32mm),11/2"(38mm)or 2" These devices may be mounted in horizontal or vertical pipe. On (50mm)pipe size.The unit may also be used as a sectional waterfiow horizontal pipe they should be installed on the top side of the pipe where detector on large systems. they will be accessible.The units should not be installed within 6"(15cm) The unit contains two single pole double throw snap action switches and of a valve,drain or fitting which changes the direction of the waterflow. an adjustable, instantly recycling pneumatic retard. The switches are Select the proper paddle for the pipe size and type of TEE used see Fig. actuated when a flow of 10 gallons per minute(38 LPM)or more occurs 1 for instructions on changing paddle.The unit has a 1"NPT bushing downstream of the device.The flow condition must exist for a period of for threading into a non-corrosive TEE.See Fig.2 for proper TEE size, time necessary to overcome the selected retard period. type and installation.Use no more than three wraps of teflon tape. Enclosure Screw the device into the TEE fitting as shown in Fig.2.Care must be The VSR-S switches and retard device are enclosed in a general purpose, taken to properly orient the device for the direction of waterflow. die-cast housing.The cover is held in place with two tamper resistant The vane must not rub the inside of the TEE or bind in any way.The 1 . screws which require a special key for removal.Afield installable cover stem should move freely when operated by hand. tamper switch is available as an option which may be used to indicate The device can also be used in copper or plastic pipe installations with unauthorized removal of the cover. See bulletin number 5401103 for the proper adapters so that the specified TEE fitting may be installed installation instructions of this switch. on the pipe run. Note:Do not leave cover off for an extended period of time. Potter Electric Signal Company,LLC•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5401206-REV G PAGE I OF 3 12/08 1 P PITFER FOR SMALL PIPE VSR-S VANE TYPE WATERFLOW ® The Symbol of Protection ALARM. SWITCH WITH RETARD Fig.1 Fig.2 1 Retard Adjustment DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME How o iron esmm•,AM,. The time delay is factory set at 30±I 0 seconds. COVER TAMPER SWITCH ` _/ _� The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting(60- ,�1� \ 1- / 1tt 90 seconds).The time delay should be set at the � 4�I� lI1 I minimum required to prevent false alarms. ;'1.\''ram J——L—`m I6.I - . � y + 1 6, "vov `1 �1 :. Screw the device into the tee fitting as shown. �1\\�i lr�t Care must be taken to properly orient the DIRECTION OF %� MOUNTI" SO ``� ���� o :.,,�� `- device for the direction of waterflow.On sweat WATER FLOW ARROW ON BUSHING0 NPT POINTS �� tees,no threaded bushings,inserts,or adapters IN DIRECTION OF ��j� WATERFLOW 1` are permitted,unless they comply with the dimensions listed in the chart below. FHEA ODEN R Important-The depth to the inside bottom of ALL ING ON the tee should have the following dimensions: SIES titi RUN OF THE TEE Approximate Depth Requirement MBE. There are 12 paddles furnished with each unit THREADEADYOR \` Tee Size Threaded sweat ("PVC SWEAT PIPE One for each size of threaded,sweat or plastic I"x r"x I. 2 1'16" I 1i4" 2 7/16" DIRECTION OF (����,,. FEE as described in Fig.2.These paddles have WECTIO OF pvw 1 Ida"x I I ia"x I" 2 7�16" 2 7�I e" NrA raised lettering that shows the pipe size and type , ter:,An 311r t Irz•x I v2 x I" 2 un 6•" 21/4" N/A of FEE that they are tobe used with.The proper 2"x2"xI" 11o6" 21,4" N/A paddlemustbeused.Thepaddlemustbeproperly Shown with optional Cover Tamper Switch Kit. attached(see drawing)and the screw that holds the paddle must be securely tightened. Do not use more than three wraps of teflon tape. Fig.3 Switch Terminal Connections Clamping Plate Terminal Fig.7 Cover Tamper Switch Wiring (Shown with cover in place) q11re aC°°�'U �' . An uninsulated section of a single conductor should not be looped • s around the terminal and serve as two separate connections.The wire O oor'U D„ri %_I., must be severed,thereby providing supervision of the connection in o°` the event that the wire become dislodged from under the terminal. (WHT) (RED) (BLK) Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. DWG"MMI0018-2 Fig.4 Typical Electrical Connections Fig.5 Fig.6 III111) To remove knockouts: Break out thin section ofcover when wiring NEGATIVE DC OR Place screwdriver at edge of both switches from one conduit entrance. i"r • ' itiAl NEUTRAL ACg , knockouts,not in the center. 1POSITIVE DCOR - • • • HOT AC1 I NEI ). II P._y ,.III -(U._ 11 I � M - IAI '���, Ill�ixne.� WATERFLOW ZONE ON \II.♦I� O I - ®/ +,' FIRE PANEL L / . ��II E �r, ..\NI�` Notes: � r / - 1. The Model VSR-S has two switches,one can be used to operate a lu� central station,proprietary or remote signaling unit,while the other 11111111 is used to operate a local audible or visual annunciator. u 2. For supervised circuits see"Switch Terminal Connections"drawing 4 - and caution note(Fig.3). PRINTED IN USA MFG.#5401206-REV G PAGE 2 OF 3 l2/08 P POTTER FOR SMALL PIPE VSR-S VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Testing Removal The frequency of inspection and testing for the Model VSR-S and its • To prevent accidental water damage,all control valves should associated protective monitoring system should be in accordance with be shut tight and the system completely drained before waterflow applicable NFPA Codes and Standards and/or the authority having detectors are removed or replaced. jurisdiction(manufacturer recommends quarterly or more frequently.) • Turn off electrical power to the detector,then disconnect wiring. An inspector'stest valve(usually located attheendofthemostremotebranch • Use a wrench on the flats of the bushing.Turn the switch line)should always be used for test purposes.If there are no provisions for counterclockwise to disengage the pipe threads. testing the operation of the flow detection device on the system,application • Gently lift with your fingers,roll the vane so it will fit through the of the VSR-S is not recommended or advisable. hole while continuing to lift the waterflow detector. A minimum flow of 10 gpm(38 Lpm)is required to activate this device. • Lift detector clear of pipe. NOTICE Please advise the person responsible for testing of the A CAUTION fire protection system that this system must be tested in accordance with the testing instructions. Waterfl ow switches that are monitoring wet pipe sprinkler systems Maintenance shall not be used as the sole initiating device to discharge AFFF, Inspect detectors monthly for leaks. If leaks are found, replace the deluge,or chemical suppression systems.Waterfl ow switches used detector.The VSR-S waterflow switch should provide years of trouble- for this application may result in unintended discharges caused free service.The retard and switch assembly are easily field replaceable. by surges,trapped air,or short retard times. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock#1029030.There is no maintenance required,only periodic testing and inspection. Mounting Dimensions 3.50" -5.56" , GROUND SCREWS (89.0 mm) (141.2 mm) �i , 2.00" � ,n (50.8 mm) MI IMIloop\ 2.34" (59.4 mm) 111,11' 1 (52.3 mm) FLOW 0j 1"-1l 1/2NPT - - DWG#1206-5 PRINTED IN USA MFG.#5401206-REV G PAGE 3 OF 3 12/08 ^ Sprinkler Gauge f F P P I® i n � . Descript o FPPI pressure gauges feature an impact and corrosion resistant case made from , > ABS (plastic). Features phosphor bronze bourdon tube movement with white ( / "enameled brass dial face with large numbers for easy reading. Dual scale to 300 , ' ' i �k G Etj$( PSI/2000Kpa. UL/ULc Listed (Sprinkler Gauge Model 111.10SP, UL Listed file 1 Boa EX5232) and FM Approved. w * oir � ' Applications Standard Features Specifications • Fire sprinkler systems Design • Suitable for all media that will not EN 837-1 &ASME B40.100 Bourdon Tube Material:copper alloy C-type obstruct the pressure system or Sizes attack copper alloy parts 4" (100 mm) Pressure Connection Material:copper alloy Accuracy class 1/4" NPT lower mount(LM) Special Features ± 3Va% of span • UL-listed (UL-393), United States (ASME B40.100 Grade B) Movement and Canada(Sprinkler Gauge Ranges Copper alloy Model 111.10SP, UL Listed file 0/80 psi, retard to 250 psi (air) Dial EX5232) 0/300 psi (air, water, air/water) White aluminum with stop pin; • Factory Mutual (FM)approved Working Pressure black and red lettering • Reliable and economical Steady: 3/4 of full scale value Pointer Fluctuating: 3/3 of full scale value Black aluminum Short time:full scale value Operating Temperature Case Ambient: -40°F to 140°F Black polycarbonate (-40°C to 60°C) Window Media: 140°F(+60°C) maximum Snap-in clear polycarbonate Temperature Error Additional error when temperature changes from reference temperature of 68°F(20°C) +0.4% for every 18°F (10°C) rising or falling. Percentage of span. _ 3198 LIONSHEAD AVE CARLSBAD,+ TEL 60599-11168 +1 800 344-1822 FAX+1 800 344-3775 I ©2012 Fire Protection Products,Inc. 1111II . . IT Model 1000 S N TE SectionalAN Floor Control Test and Drain Valve c �Lus APP 3/4" 1" 11/4" 11/2" 2" TEST PUSH TESTANDRAIN ra zen��sr:"� 19 sF • yq9 A 59�c S � •The AGF Manufacturing Inc. Model 1000 TESTANDRAIN® MODEL 1000- FRONT VIEW,VERTICAL INSTALLATION provides both the test function and the express drain function for a wet fire sprinkler system. •The Model 1000 complies with the requirements of I FROM BRANCH NFPA-13, NFPA-13R, and NFPA-13D. SYSTEM ACCESS PORT •The Model 1000 TESTANDRAIN®is a compact single handle ball valve which includes a tamper resistant test __ ;�i orifice and integral tamper resistant sight glasses, and is m 300 PSI rated. "1 •Available in a full range of sizes from 3/a" to 2" NPT and BSPT, with all specifiable orifice sizes 3/a" (2.8K),7/16" (4.2K), STREET EL �l 1" (5.6K), 17/32" (8.0K), Vs" (11.2K, ELO), 3A" (14.0K, ESFR), (TA and K25 as required by NFPA 13, 2007 Edition (see reverse). •The orifice size is noted on the indicator plate and the valve features a tapped and plugged port for system access. STREET EL TO DRAIN • A locking kit is available and can be ordered with the valve OR PIPE to provide vandal resistance or prevent unintentional alarm TO DRAIN 1 activation. • Repair kits including (1) adapter gasket, (1) ball, (2) valve seats, (1)stem packing, and (1)stem washer are available for all TESTANDRAIN®valves.Valve and orifice size must RIGHT HAND/STRAIGHT INSTALLATION be specified when ordering. Reliability, Versatility, Code Compatibility TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. CS1000 10/09 Model 1000 AP cl us TESTAN DRAIN® APPROVED300 PSI Bronze Ball Valve MODEL 1000 - PLAN VIEW FRONT VIEW - HORIZONTAL INSTALL E ►I • I IBM 1/2"ANPT SYSTEM I Ci • 1ST ACCESS PORT J F IIII TO DRAIN I_. � ��� ■ TOE DRAIN 1- H � FM% ill•j - • III=I■ . N D- 01• - - ■ 111 C G IC) • I 1 El DIMENSIONS MATERIALS Orifice Size Available:3/8",7/16", 1/2", 17/32", ELO(5/8")*, ESFR(3/4")`,&K25** Handle:Steel Stem: Rod Brass SIZE A B C D E F G H Ball:C.P. Brass 3/4.. 51/16" 11/2" 23/16" 35/8" 33/8" 113/is" 49/1s" 63A" Body: Bronze (128 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) Valve Seat: Impregnated Teflon® 51/is" 11/2" 23/is" 35/8" 33/8" 113/is" 49/16" 63/8" Indicator Plate:Steel 1 (128 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) Handle Stop: Steel 11/4" 57/16" 111/16" 29/16" 41/4" 35/s" 115/16" 59/16" 51/2" APPROVALS (163 mm) (43 mm) (65 mm) (108 mm) (83 mm) (51 mm) (141 mm) (192 mm) UL and ULC Listed(EX4019) 11/2" 67/16" 113/16" 31/4" 51/16" 37/8" 25/8" 81/4" 107/8" FM Approved (163 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) NYC-BSA No.720-87-SM 2" 67/s" 113/s" 31/4" 51/s" 37/8" 25/8" 81/4" 104„ (163 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 41. Available on 11/a" to 2" size units only **Available on 11/2" and 2" size units only «« w THE MODEL 1000 PROVIDES ALL OF THE FOLLOWING... MADE IN U.S.A. From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s)-shall be provided with a drain &8.16.2.4.3 connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into a drain capable of accepting full flow... using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. ' Chapter 8.17.4.2.4 shall be permitted to be installed in any location... downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion-resistant orifice,to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1", at least one of which shall be brass. USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. Job Name: G100 Quaker Lane,Malvern,PA 19355 A Phone:610-240-4900 Architect: F Fax:610-240-4906 Engineer: www.testandrain.com Contractor: Aalygg010 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC - COPPER - STEEL HANGER 0 510 Fastener SIZE 2.1251m. 0 1 4 3/4 2.312 1 1/4 3.170 1 1/2 3.400 ® 2 4.010 2 1/2 4.320 3 5.320 SIZE-SYSTEM PIPE: 3/4"thru 3" MATERIAL-Carbon Steel. FINISH-Mil.Galvanized. LISTING/APPROVAL- `0"203-EX 4231,EX 2551 FUNCTION-Support horizontal piping: CPVC,Copper or Steel. Size 3/4"-2"Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION- Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS- UL Listed per NFPA 13 in WOOD: 3/4"-3"CPVC pipe-#905 screw-no pre-drill. 3/4"-3" Steel and Copper pipe-#14 x 1 1/2" SMS or Restraint 1/4"x11/2" lag bolt-no pre-drill. in STEEL-min. 18 GA. 3/4"-3"CPVC,Copper and Steel pipe- 1/4"or#14 Tek Screw. Mill loft FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. *Required AFCON#905 screw included-5/16"hex head. Hanger Ts�� MI Stabilize • ORDERING-Part#and pipe size. r �� CAN ALSO BE USED TO REPLACE -#500 Pipe Strap #520 Tin Strap Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-A FCON products have been,or are used. 5/14 „ CPVC (7r) Fig. 188R(Formerly Afcon Fig. 514) Two Hole Standoff and Restrainer Size Range:'/4"through 2" Material:Carbon Steel Finish:Pre-Galvanized per ASTM A653 �• ,.,< C US Service: . k LISTED • Hanger and surge restraint for horizontal CPVC piping when installed on the top,bot- e tom,and side of the supporting structure. �., • Guide for vertical CPVC piping when installed on the side of the supporting structure. ' • Horizontal and vertical seismic restraint per NFPA 13-2016 requirements. • Listed with hardware provided on structural wood beams and composite wood beams M (1"minimum).Listed with steel(18ga minimum)with two(2)#14x1"or'/4"xl"hex washer head self-drilling TEK screws.For wood structures with less than 1"thickness,wood , ''';.1„. blocks may be placed on the backside of the wood structure.#10x1"fastener provided . must be fully engaged in the wood block. ,,.4. • May be installed with concrete,steel structural members,and other structural members with fasteners which comply with the requirements of NFPA 13. Approvals:cULus Listed Patents:No.6,648,278 Installation: • Snap hanger over pipe. If needed,squeeze strap back around pipe. • CPVC pipe must be allowed to slide freely through the Fig.188R. • Secure hanger to mounting surface with screws provided or with listed fasteners. Features: "``411) • Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. i.so • Easilyattaches to wood structure with#10 x 1"hex washer head self-threadingscrew supplied with PP .n+r' product.No pre-drilling required. • Bottom of pipe is offset 1%2"from the structure. Eliminates wooden spacer blocks. Ordering:Specify CPVC pipe size,figure number and description. Hanger& :: Restrainer Y 1111111kInstallation-Backing Nut Hanger=1 at top fastener Restraint=2-on each fastener Hanger& - Guide& Per NFPA-13D and NFPA-13R Restrainer ''O, �.— R111 estrainer il II lil • PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: ['Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.18 CPVC (23).AwiL Fig. 188R(Formerly Afcon Fig. 514) Two Hole Standoff and Restrainer(cont.) a a B a d ° a ° ar , A1 as a ° a a a ° a d E 'O' 0('iaa D.,a 4.a a a ° a L a 4 a a a d a a - a A A W W \,, i F D 1 O G Hanger and Restrainer FIG.188R: DIMENSIONS (IN) • WEIGHT (LBS) CPVC A B gC D E F G Max. Hanger Approx. Pipe Size Spacing(FT.) Weight/100(Ibs) - 3/4 23/4 31/2 1/4 2 1 _ 25/6 11/2 51/2 11 1 213%6 31/2 1/4 23/6 1 215%6 11/2 _ 6 12 11/4 213/6 31/2 1/4 25/6 1 31/4 11/2 61/2 13 11/2 35/6 41/4 1/4 27/16 _ 1 31/2 11/2 7 14 2 311/6 43/6 1/4 211/16 1 4 11/2 8 16 • PH-1.18 208 illAy!sl D Ai 81:3uC 11 LET YD CE NRO GF TIGFIL) I jQ WYAT T FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 ANNAND HILL TRIPLEXES 10847- 10895 SW ANNAND CT TIGARD, OR 97224 FIRE PROTECTION HYDRAULIC CALCULATIONS CALCULATION SUMMARY Project Name:Annand Hill Triplexes Project Location: 10849 SW Annand Hill Ct Contract No.: City: Tigard, OR 97224 Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/ft2) (psi) (gpm) # (gpm) (psi) 3rd Floor Demand (HW) 512 26.2 Required 0.051 7 13 2 0 15.1 42.9 File:C:\Users\Ronin\AppData\Local\Temp\Annand Hill Triplex_1_14722_60147325.sv$ Date 4/28/2022 Copyright©2002-2012 Tyco Fire Protection Products Page 1 HYDRAULIC CALCULATIONS for Job Information Project Name:Annand Hill Triplexes Contract No.: City: Tigard, OR 97224 Project Location: 10849 SW Annand Hill Ct Date:4/28/2022 Contractor Information Name of Contractor: Wyatt Fire Protection Address: 9095 SW Burnham St City: Tigard, OR 97223 Phone Number: 503-684-2928 E-mail: Name of Designer: Authority Having Jurisdiction: Design Remote Area Name 3rd Floor Remote Area Location Occupancy Classification Density(gpm/ft2) 0.051 Area of Application(ft2) 512 Coverage per Sprinkler(ft2) 256 Number of Calculated Sprinklers 2 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 0 Total Water Required(incl.Hose Streams)(gpm) 26.2 Required Pressure at Source(psi) 42.9 Type of System Wet Volume-Entire System (gal) 11 gal Water Supply Information Date 4/26/22 Location 10849 SW Annand Hill Ct. Source W1 Notes File:C:\Users\Ronin\AppData\Local\Temp\Annand Hill Triplex_1_14722_60147325.sv$ Date 4/28/2022 Copyright O 2002-2012 Tyco Fire Protection Products Page 2 Job:Annand Hill Triplexes Hydraulic Analysis for : 3rd Floor Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (Ib/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 58 2180 20 Supply Analysis Residual Available Static Pressure Flow Total Demand Required Pressure Node at Source Pressure Pressure (Psi) (Psi) (gpm) (psi) (gpm) (Psi) W1 58 20 2180 58 26.2 42.9 Hoses Inside Hose Flow/Standpipe Demand(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) Total Hose Flow(gpm) Sprinklers Ovehead Sprinkler Flow(gpm) 26.2 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 26.2 Other Required Margin of Safety(psi) 0 W1 -Pressure(psi) 42.9 W1 -Flow(gpm) 26.2 Demand w/o System Pump(s) N/A File:C:\Users\Ronin\AppData\Local\TempWnnand Hill Triplex_1_14722_60147325.sv$ Date 4/28/2022 Copyright©2002-2012 Tyco Fire Protection Products Page 3 Job:Annand Hill Triplexes Hydraulic Analysis for : 3rd Floor f Supply iii System Demand . AvailableAt Source 1 80 i i t , .! , .1 .1 i I .� i i , 1 I 1 _. 70 L_} I i 1 i i I I i € ! 58 psi 26.2 g pm t { 1 , ...I_ t _ 1 i i I 5n_ , I I I i i l 1 t I i,. i t 3 I 11 � r i 1 r n ...pori. i 1 1; 1 i' } I I: t _1 r _.,z t .{ i I 10 s 0 60T08090000010020030040015001600170018001900 2000 2100 2200 2200 Flow, gpm 1 1 I 1 File C:\Users\Ronin\AppData\Local\Temp\Annand Hill Triplex_1_14722_60147325.sv$ Date 4/28/2022 Copyright©2002-2012 Tyco Fire Protection Products Page 4 , Job:Annand Hill Triplexes Hydraulic Analysis for : 3rd Floor Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 58 S2 Supply point#2-Residual 2180 20 D1 Elevation Pressure 0 13.7 D2 System Demand 26.2 42.9 Curve Intersections &Safety Margins Intersection Safety Margin Curve Name Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 58 32.8 15.1 26.2 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) h1 Overhead 256 4.9 0.05 12.8 7 0.052 13.2 7.3 Sprinkler h2 Overhead 256 4.9 0.05 12.8 7 0.051 13 7 Sprinkler File:C:\Users\Ronin AppData\Local\Temp\Annand Hill Triplex_1_14722_60147325.sv$ Date 4/28/2022 Copyright©2002-2012 Tyco Fire Protection Products Page 5 Job name:Annand Hill Triplexes Sheet number: PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added(q)* Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) h2 28.58 4.9 13 1 lx(BM.Tee-Run)=1 10.92 150 7 01 30 13 1.101 lx(BM.90)=5 6 0.0304 -0.6 16.92 0.5 01 30 13.2 1 8x(BM.90)=40 67.31 150 6.9 22-0 3.86 26.2 1.101 4x(BM.Tee-Run)=4 54 0.1118 11.3 2x(BM.Tee-Br)=10 121.31 13.6 22-0 3.86 0 1 1.1 31.8 Ames2000B 22-I 2.76 26.2 0 0 3.5959 0.5 *** 1.1 4 22-I 2.76 0 1 2.76 150 36.2 23 0 26.2 1.101 0 0.1118 1.2 2.76 0.3 23 0 0 1.5 2x(BM.45)=4 31.53 150 37.7 27-0 -3 26.2 1.598 lx(BM.Tee-Br)=8 12 0.0182 1.3 43.53 0.8 27-0 -3 0 1 0.9 39.8 Neptune T-10 27-I -3 26.2 0 0 2.6923 0 *** 0.9 2.4 27-I -3 0 1.5 34.49 150 42.3 W 1 -3 26.2 1.598 0 0.0182 0 34.49 0.6 hl 28.58 4.9 13.2 1 1x(BM.Tee-Br)=5 1.42 150 7.3 01 30 13.2 1.101 5 0.0316 -0.6 6.42 0.2 * Discharge shown for flowing nodes only ©2006 National Fire Protection Association Page 6 W YAT T FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard.OR 97223 Fire Hydrant Fire Flow PROJECT ANNAND Hill Triplexes ADDRESS 10849 SW Annand Hill Ct. Tigard, OR. 97224 CROSS STREET FLOW HYDRANT 10849 SW Annand Hill Ct. LOCATION STATIC 58 PITOT RESIDUAL 15, flowed 4" hose monster GPM 1456 GPM AT 20 PSI 2180, 31% pressure drop, calculated per NFPA 291 DATED 3/10/2022 f MONITOR r HYDRANT SW 109th & SW Murdock St. LOCATION STATIC 58 RESIDUAL 40 DATED 3/10/2022 WITNESS WITNESSED BY TITLE ORGANIZATION City of Tigard Public Works SIGNATURE PERFORMED BY Jack Gardner