Report Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: r( Z p Z — (9'b 303 Jurisdiction: i� 0.9.4)
Site Address: I to ct,t )p i, ! L P
Subdivision/Lot#: ,,a Q , 1 b`-- Z b 3
and/or ►►""��
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: CG/ Date: /
Z Z'
caner/General Conutho -
Print Name: v 4.,77z Bee
i ORSC Section N1107.2.High-efficiency interior lighting,systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\BuildingWorms\RES-HighEfficiencyLighting.doc 07/01/08
Form 640S 2017
Completion Certification—Site Inspection AL
New Homes Program—Single Family r)7
of Oregon
To be completed by Verifier
CLEAResult is a Program Management Contractor for Energy Trust of Oregon,Inc.
Payment Information
Incentive Payee Company Name: 'Taylor Morrison Inc Portland Division I Is this payment redirected?: INo
Builder or Company: Taylor Morrison Inc Portland Division Redirect to Name:
Verifier Payee Company Name: Performance Insulation and Energy Redirect Payee Corn
Affordable Housing No
Solar Ready Builder Incentive: 'Solar ReadyVerifier Ince
Site Information
Development RT 4 Eastndge II Med Lot �v 071777 Axis ID: I 'REM/Rate®ID:
ez��� re r r�mrm re r to 4I111i\�}
Address, ;'� ,C'++�, ��^�a�„+ ����,�,J�:,1e a1v��m, L�. a���1�u}"u x a�vN�.�,
Street Line 2 Multi-Family INo `City: Tigard State: OR Zip: 97224
Total conditioned area(sq.ft.): 2,265 House Volume: I 22,867 Housing Type: Detached single family
Number of Stones: 12 Number of Bedrooms: 3 Foundation Type: Crawlspace
Electric Provider: Portland General Electric Gas Provider: NW Natural Gas
Solar installed Solar Installer Name/Company:
Blue shaded fields are required for EPS sheet
Verification Type Actual Model Equipment Details&Notes
Slab Perimeter Insulation R- 0.0 Slab Under Insulation R-
InsulationFramed Floor R- 30.0 Secondary Framed Floor R- 59.0
Above Grade Wall Insulation R- 23.0 Below Grade Wall Insulation R-
Flat Ceiling Insulation R- 49.0 Vaulted Ceiling Insulation R-
Windows Windows U- 0.3 SHGC:I0.3 Total window area: 1420
Cooling Air Conditioning SEER: 0 Model#:
Primary Heating System Details AFUE: 95 Brand Lennox
Type: Gas Furnace HSPF: Model#: ML196U1-1090XE48C-51
Heating Fuel: Gas SEER:
Primary Heat
Source Comment: COP:
Location: Attic Outdoor Unit(for heat pumps)
ECM: No Model#: I
AHRI Certificate:4805339 #of Systems 11
Gallons: I Brand: AOSmith
Water Heater Type Heat Pump EF: I Model#: HPTU-66N 130
Water Heating Fuel Electric Location: 'Garage or ope AHRI Certificate:
Ducts and Duct Location 'Partial - %ducts inside T,�atu�� Duct Leakage(CFM)@ 50Pa AdgZiligiii 2 7757,
Testing
Infiltration Air Changes per Hour(ACH)@ 50Pa: 3.47 I
Ventilation Ventilation Type HRV/ERV Model:
Supply Side-Air Cycler Airflow measured or why untestable? 'Roof Termination
Appliances
Refrigerator kWh/yr _ Model:
ENERGY STAR Diswasher kWh/yr 270 Model: GDF51"'M"'
Percent High Efficacy Interior Lighting(%) 100% Thermostat
Showerhead 1.5 GPH I Showerwand 1.5 GPH I Showerhead 1.6 GPH I IShowerhead 1.75 GPH I
Notes:
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, -1 s- /L4✓1- Nt 444 Spit , am the general contractor or the owner-builder
at the following address:
Site Address: I Le S-u/ _ 9,14) `D )I dt_eroP
City: '1 614120
Permit#: M ler Zd Z I - vv 03
SubdivisionfLot#: L b Z o3
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: L�l Date: / Ct' ZZ,
General Contractor Owner-Builder
I:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
1, --rev y 1(rtuti svi , am the general contractor or the owner-builder
at the following address:
Site Address: I Le viz -11 a Lo-vP
City: #1&14414)
Permit#: M vr Zb Z 1 - (`rU 3 a 3
Subdivision/Lot#: J - L-r Zo3
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
Joints lapped 12"at seams and
xtending up the foundation walls 12".
Signature: _ �/ Date: 7 /
7iZ
General Contractor or wner-B.,:gilikr
I;\Building\Fotm\RF.S-MoistureBanietdoc 09/13/2016