Correspondence MS1-27)Z 1 r oo�3 5 /(06 D J c-oc r CT ENGINEERING IN C 180 Nickerson St. Suite 302 Seattle,WA 98109 (206)285-4512(V) (206)285-0618(F) asolomon@ctengineeriug.com BULLETIN Date: June 30, 2022 Number: CT-117 Project#: 15238 Project Name: River Terrace Area 4 SF Attached: None Subject: Lot 222 (Plan 222503D)— Header Revisions Drawings Affected: Sheet A7 (Upper Level Floor Framing Plan) Description/Action: This bulletin provides response to RFI's, design clarifications and/or variation requests for the 'River Terrace Area 4 SF' project located in Tigard, Oregon. Per our discussion with Taylor Morrison, it's our understanding that for the lot/plan type noted above, 4x10 headers were installed over the main floor dining room window, living room window & sliding glass door. The plans show 6x10 headers are required at these three locations. Based on our review of the plans, attaching a single 2x10 to each existing 4x10 header provides a proper fix. Attach a 2x10 to each 4x10 w/(2) rows of 0.148"x3" nails @ 12"o.c. 5-cRUCTUR44 5) PRo, Co g W cff ti ON ,\ 4, • 12, 1§�`� F. R00 06/30/2022 CALL WITH ANY QUESTIONS Issued by: Arnold R. Solomon Date: June 30, 2022 Distribution: Contact Information: Dennis Gaudreault Taylor Morrison Frank Sandoval Taylor Morrison Sam Scott Taylor Morrison Amy Russell Taylor Morrison Elizabeth Erlandson Milbrandt Architects R:\15238 River Terrace SF\Bulletins115238_2022.06.30_CT117_Lot 222(Plan 222503D)_Header Revisions.doc Structural Engineers