Date: June 30, 2022 Number: CT-117 Project#: 15238
Project Name: River Terrace Area 4 SF Attached: None
Subject: Lot 222 (Plan 222503D)— Header Revisions
Drawings Affected: Sheet A7 (Upper Level Floor Framing Plan)
Description/Action:
This bulletin provides response to RFI's, design clarifications and/or variation requests for the 'River
Terrace Area 4 SF' project located in Tigard, Oregon.
Per our discussion with Taylor Morrison, it's our understanding that for the lot/plan type noted above,
4x10 headers were installed over the main floor dining room window, living room window & sliding
glass door. The plans show 6x10 headers are required at these three locations.
Based on our review of the plans, attaching a single 2x10 to each existing 4x10 header provides a
proper fix. Attach a 2x10 to each 4x10 w/(2) rows of 0.148"x3" nails @ 12"o.c.