Report OFFICE COPY
COMcheck Software Version COMcheckWeb
44 ril
Interior Lighting Compliance Certif
-IVED
JUN112021
Project Information CITY OF TIGARD
Energy Code: 90.1 (2019) Standard BUILDING DIVISION
Project Title: Peloton at Washington Square p,IP LL o 7 /_ a p/3 s
Project Type: Addition ✓�
93797/ WA- ' .SQ1
Construction Site: Owner/Agent: Designer/Contractor:
9355 SW Washington Square road One Peloton Thorson Baker and Associates
Portland, Oregon 97223 441 Ninth Avenue, Sixth Floor 3030 W Streetsboro Road
New York, New York 10001 Richfield, Ohio 44286
979-229-0987
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed
(ft2) Watts/ft2 Watts
1-Main Sales(Retail:Sales Area) 1463 1.05 1536
Allowance: Other retail highlighting/Fix. ID: Cl 1097(a) 0.45 494(b)
2-Secondary Sales(Retail:Sales Area) 495 1.05 520
3-Trial Room 1 (Common Space Types:Office-Enclosed <=250 sq ft) 82 0.74 61
4-Trial Room 2 (Common Space Types:Office-Enclosed <=250 sq ft) 82 0.74 61
5-Trial Room 3 (Common Space Types:Office- Enclosed <=250 sq ft) 103 0.74 76
6-Trial Room 4 (Common Space Types:Office- Enclosed <=250 sq ft) 103 0.74 76
7-Storage closet(Common Space Types:Storage >=50- <=1000 sq.ft.) 55 0.43 24
8-Restroom (Common Space Types:Restrooms) 100 0.63 63
9-BOH (Common Space Types:Storage >=50- <=1000 sq.ft.) 426 0.43 183
I 10-Fitting Room (Retail:Dressing/Fitting Room) 47 0.51 24
Supplemental Allowed Watts(null) = 94
Total Allowed Watts= 3211
(a)Area claimed must not exceed the illuminated area permitted for this allowance type.
(b)Allowance is(B x C)or the actual wattage of the fixtures given in Section 2, whichever is less.
(c)Supplemental watts must be associated with retail merchandise highlighting fixtures. Supplemental watts are not included
calculation of lighting complaince percentage.
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description / Lamp /Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
1-Main Sales (Retail:Sales Area)
LED: D2: LED Downlight: Other: 1 22 18 396
LED: Cl: Linear Cove: Other: 1 147 4 588
LED: P3: Pendant Fixture: Other: 1 4 17 68
2-Secondary Sales (Retail:Sales Area)
LED: D2: LED Downlight: Other: 1 11 18 198
LED: Cl: Linear Cove: Other: 1 32 4 128
LED: P3: Pendant Fixture: Other: 1 1 51 51
3-Trial Room 1 (Common Space Types:Office - Enclosed <=250 sq ft)
LED: L7: Linear LED: Other: 1 24 4 96
Project Title: Peloton at Washington Square Report date: 06/07/21
Data filename: Page 1 of 6
A B C D E
Fixture ID : Description / Lamp /Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
4-Trial Room 2 (Common Space Types:Office - Enclosed <=250 sq ft)
LED: L7: Linear LED: Other: 1 24 4 96
5-Trial Room 3 (Common Space Types:Office - Enclosed <=250 sq ft)
LED: L7: Linear LED: Other: 1 30 4 120
6-Trial Room 4 (Common Space Types:Office - Enclosed <=250 sq ft)
LED: L7: Linear LED: Other: 1 30 4 120
7-Storage closet (Common Space Types:Storage >=50 - <=1000 sq.ft.)
LED: D2: LED Downlight: Other: 1 4 18 72
8-Restroom (Common Space Types:Restrooms)
LED: D3: LED Downlight: Other: 1 4 14 56
LED: P4: Mirror Pendant: Other: 1 1 10 10
9-BOH (Common Space Types:Storage >=50 - <=1000 sq.ft.)
LED: L5: LED Flat Panel: Other: 1 15 38 570
10-Fitting Room (Retail:Dressing/Fitting Room)
LED: D2: LED Downlight: Other: 1 2 18 36
Total Proposed Watts = 2605
Interior Lighting PASSES: Design 16%better than code
Interior Lighting Compliance
Statement
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been
designed to meet the 90.1 (2019) Standard requirements in COMcheck V. sion COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist. ,/�/
Jeff D. Miterko, P.E. 6/9/2021
Name-Title Signature Date
Project Title: Peloton at Washington Square Report date: 06/07/21
Data filename: Page 2 of 6
.
(II COMcheck Software Version COMcheckWeb
Inspection Checklist
Energy Code: 90.1 (2019) Standard
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.tD
4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met.
8.4.1.1, calculations provide all information ❑Does Not
8.4.1.2, with which compliance can be
8.7 determined for the electrical systems ❑Not Observable
[PR6]2 and equipment and document where ❑Not Applicable
exceptions are claimed. Feeder
connectors sized in accordance with
approved plans and branch circuits
sized for maximum drop of 3%.
4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met.
9.4.3, 9.7 calculations provide all information ❑Does Not
[PR4]1 with which compliance can be
determined for the interior lighting ❑Not Observable
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Additional Comments/Assumptions:
L11High Impact(Tier 1) I Medium Impact(Tier 2) 3 Low Impact(Tier 3) ;
Project Title: Peloton at Washington Square Report date: 06/07/21
Data filename: Page 3 of 6
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.lD_
j8.4.2 At least 50%of all 125 volt 15-and ❑Complies Exception: Space type is not private office, open office, or
1[EL10]2 20-Amp receptacles are controlled by ❑Does Not computer classroom.
an automatic control device.
❑Not Observable
❑Not Applicable
8.4.3 New buildings have electrical energy ❑Complies Requirement will be met.
[EL11]2 use measurement devices installed. ❑Does Not
Where tenant spaces exist, each
tenant is monitored separately. In [Not Observable
buildings with a digital control system ❑Not Applicable
the energy use is transmitted to to
control system and displayed
graphically.
9.4.1.1 Automatic control requirements ❑Complies Requirement will be met.
[EL1]2 prescribed in Table 9.6.1,for the ElDoes Not
appropriate space type, are installed.
Mandatory lighting controls(labeled ['Not Observable
as 'REQ') and optional choice controls ❑Not Applicable
(labeled as'ADD1' and 'ADD2')are
implemented.
9.4.1.1a Independent lighting controls installed ❑Complies Requirement will be met.
[EL2]2 per approved lighting plans and all ❑Does Not
manual controls readily accessible and Not Observable
visible to occupants.
❑Not Applicable
9.4.1.1b No lighting shall be automatically ❑Complies Exception: Manual on function would endanger safety and
[EL26]2 turned on-restriced to manual. ❑Does Not security.
❑Not Observable
❑Not Applicable
-------------------------------
9.4.1.1c <= 50%of general lighting power ❑Complies Requirement will be met.
[EL27]2 shall be allowed to be automatically ❑Does Not
turned on.
❑Not Observable
❑Not Applicable
9.4.1.1d Bilevel lighting control- <= 50%of ❑Complies Requirement will be met.
[EL28]2 general lighting controlled with one ❑Does Not
intermediate step between full off and
full on. ❑Not Observable
❑Not Applicable
9.4.1.1e Automatic daylight responsive ❑Complies Exception: Retail lighting.
[EL29]2 controls for sidelighting >= 150 watts ❑Does Not
controlled by photocontrols.
❑Not Observable
ElNot Applicable
j9.4.1.1f Automatic daylight responsive ❑Complies Exception: Requirement does not apply.
[EL30]2 controls for toplighting >= 150 watts ❑Does Not
controlled by photocontrols.
DNot Observable
❑Not Applicable
9.4.1.1g Automatic partial OFF: lighting shall ❑Complies Requirement will be met.
[EL31]2 be reduced >= 50%within 20 minutes ❑Does Not
of zero occupancy.
[Not Observable
❑Not Applicable
9.4.1.1h Automatic full OFF: lighting shall be ❑Complies Exception: General lighting and task lighting in spaces where
[EL32]2 shut off within 20 minutes of zero ❑Does Not automatic shutoff would endanger the safety or security of
occupancy. room or building occupants.
❑Not Observable
❑Not Applicable
9.4.1.1i Scheduled shutoff: all lighting shall be ❑Complies Requirement will be met.
[EL33]2 shut off when scheduled to be ❑Does Not
unoccupied.
[Not Observable
❑Not Applicable
1 !High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Peloton at Washington Square Report date: 06/07/21
Data filename: Page 4 of 6
Section
# Rough-in Electrical Inspection Complies? Comments/Assumptions
& Req.IDI j I
9.4.1.3 Separate lighting control devices for ❑Complies Requirement will be met.
[EL4]1 specific uses installed per approved ❑Does Not
lighting plans.
❑Not Observable
❑Not Applicable
9.6.2 Additional interior lighting power ❑Complies Requirement will be met.
[EL8]1 allowed for special functions per the ❑Does Not
approved lighting plans and is
automatically controlled and ['Not Observable
separated from general lighting. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) TiLow Impact(Tier 3) J
Project Title: Peloton at Washington Square Report date: 06/07/21
Data filename: Page 5 of 6
. "
Section
� Final Inspection Complies? [ Comments/Assumptions
&Req.^D
8.7.1 Furnished as-built drawings for LJComp|ies Requirement will Uemet.
[F|15]3 electric power systems within]Odays []Does Not
or system acceptance,
[]No,ObsemaU|e
[]Not Applicable
8J.2 Furnished O&M instructions for []Complies Requirement will be met.
[R17]3 systems and equipment,othe []ooesmm
� building owner o,designated
representative. []mo'ObservaNe
[]wotxpp|icab|e
� ---Interior installed lamp and fixture []Compx —�
es ~~the Interior Lighting fixture schedule for values.
� [n18]1 lighting power isconsistent with what []Dueswot
is shown on the approved lighting
plans, demonstrating pm' ed a�s []mot0bservaU|e
are less than n/equal toallowed []mo,App|icab|e
watts.
9.4.4 A,least 75%of all permanently []Complies Requirement will Uemet.
[p120]/ installed lighting fixtures mdwelling []onesmm
units have ^~ nx |m/W efficacyra
->~ 45 |m/Wtota| |uminaie efficacy. []motObservable
[]motApp|icaU|e
Additional Comments/Assumptions:
h k�nh Inpact(TlerI) Impact ] Low —
Project Title: Pe|oton at Washington Square Report date: 06/ 7/2l
Data filename: Page 6 or 6