Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (63)
M EC2020-00141 Architect/ Engineer: a,re a� t� � Hing RECEIVE. � TIGARD 98TH AVENUE MEETINGHOUSE ,l"Prove �b _-. -- .. MAR 1 2 `r' LO N pate:S _ �� CITY OF TIGAR Lr }, N HVAC UPDATE Initial BUILDING DTVI In Cn ( N TUALATI N OREGON STAKE Q 0 Mo ° L W TIGARD , OREGON 0 o � o GENERAL CONTRACT NOTES 1. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. ALL DIMENSIONS SHALL BE FIELD VERIFIED AND COORDINATED WITH THE WORK OF ALL TRADES.THE ARCHITECT SHALL BE NOTIFIED Stamp: - - - - PROPERTY LINE 666.5' IMMEDIATELY IF ANY DISCREPANCIES ARE DISCOVERED. �tiD ARS LANDSCAPING 2. DIMENSIONS SHOWN ON PLANS ARE TO FACE OF EXTERIOR WALL, CENTERLINE OF STRUCTURE, AND FACE OF STUDS UNLESS OTHERWISE NOTED. 5,;OFF STA3. THE CONTRACTOR SHALL EXAMINE THE CONDITION OF THE PROJECT AREA AND PRIOR TO COMMENCEMENT OF 831WORK, REPORT ALL DISCREPANCIES TO THE ARCHITECT. VERIFY ALL REQUIRED OPENINGS AND SLEEVES IN BEAMS, SLABS, WALLS, ETC. WITH ALL TRADES BEFORE START OF WORK. COMMENCING WITH CONSTRUCTION SIGNIFIES TLFlN ORACCEPTANCE OF CONDITION OF PROJECT AREA. 4. SHOULD THE DRAWINGS DISAGREE IN THEMSELVES OR WITH THE SPECIFICATIONS OR SHOULD THE SPECIFICATIONS OOCP DISAGREE IN THEMSELVES, THE BETTER QUALITY AND/OR GREATER QUANTITY OF WORK OR MATERIAL SHALL BE ESTIMATED AND SHALL BE FURNISHED AND INSTALLED. 5. IF ANY ERROR OR OMISSION APPEARS IN THE CONTRACT DOCUMENTS, CONTRACTOR SHALL NOTIFY ARCHITECT IN 1 i 1 WRITING OF SUCH ERROR OR OMISSION PRIOR TO COMMENCING WORK. UJ �w 6. GENERAL CONTRACTOR SHALL COORDINATE WORK PERFORMED BY OTHER CONTRACTORS.DISCREPANCIES, IF ANY, V J W 1S SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR RESOLUTION BEFORE < Z N PROCEEDING WITH WORK. O Z r W W m 7. GENERAL CONTRACTOR SHALL, IN THE WORK OF ALL TRADES, PERFORM ANY AND ALL CUTTING, PATCHING, 2 Q Q 0 REPAIRING, RESTORING AND THE LIKE NECESSARY TO COMPLETE THE WORK AND TO RESTORE ANY DAMAGED OR 00 0 = Ur LANDSCAPING AFFECTED SURFACES RESULTING FROM THE WORK OF THIS CONTRACT TO THEIR ORIGINAL CONDITION, AND TO THE a LU SATISFACTION OF THE ARCHITECT AND THE OWNER, 00 0Y 8. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE TIMELY ARRIVAL OF ALL SPECIFIED FINISH MATERIALS, j U) p d , ° ° ♦' °' ..d - ° ° ° a.. -% d ; - - - ' > - d < EQUIPMENT, LIGHT FIXTURES AND ANY OTHER SUCH MATERIALS TO BE UTILIZED ON THIS PROJECT, THE GENERAL _ of d ° $ ° ° . d CONTRACTOR IS ALSO RESPONSIBLE FOR UNLOADING ALL OWNER SUPPLIED MATERIALS AT THE JOB SITE (UNCRATE, W do °' LO d' • ASSEMBLE AND PLACE WHERE INDICATED ON PLAN OR PER OWNER'S INSTRUCTIONS). LO (E) MOW STRIP d LANDSCAPING (E) MECHANICAL ( n w ENCLOSURE 9. SAFETY: ALL CONDUCT, WORK EQUIPMENT, AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST v C (N) MECHANICAL SAFETY RULES AND REGULATIONS OF ALL AUTHORITIES AND AGENCIES HAVING JURISDICTION OVER THE WORK. G ENCLOSURE LANDSCAPING e 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND OBTAINS ALL PERMITS, LICENSES, AND PAY REQUIRED FEES. e ACCESSIBLE 11. ALL REQUIRED PERMITS MUST BE OBTAINED FROM THE REQUIRED GOVERNING AGENCIES BEFORE BUILDING IS ROUTE OCCUPIED. ° r r 12. TEMPORARY TOILET FACILITIES TO BE PROVIDED PER REQUIREMENTS OF LOCAL GOVERNING AGENCY. [� ° °°' 13. EACH CONTRACTOR SHALL LEAVE THE SITE IN A NEAT, CLEAN, AND ORDERLY CONDITION UPON CONCLUSION OF a.° WORK. ALL WASTE, RUBBISH, AND EXCESS MATERIALS SHALL BE REMOVED FROM THE SITE PROPERLY. °, ` b' PROJECT DIRECTORY o x U t " C H OWNER'S REPRESENTATIVE ARCHITECT MECHANICAL/ELECTRICAL ENGINEER W E < MEETINGHOUSE FACILITIES DEPARTMENT JOHN A. STARK, ARCHITECT MFIA INC. CONSULTING ENGINEERS .T LJ SCOTT ROBISON P.O. BOX 23215 CONTACT PERSON: SCOTT MILLER H V) co d° :D 1271 OVERLOOK DRIVE r�1 W z LAKE OSWEGO, OR 97034 PORTLAND, OR 97281 2007 SE ASH STREET W Q CN NG LANDSCAPING LLI ROBISONST@LDSCHURCH.ORG JSBELLOPUS@MSN.COM PORTLAND, OR 97214 LANDSCAPI LU c EXISTING LANDSCAPING Z > OFFICE: 503.638.0824 PHONE: 503.544.6840 SCOTT.MILLER@MFIA-ENG.COM J BUILDING Q CELL: 801.718.1217 FAX: 503.213.6181 PHONE: 503.234.0548 � = FAX: 503.234.0677 ii I d a 0 00 IL PROJECT INFORMATION PROJECT SUMMARY OFFICE CC)py JOB ADDRESS OCCUPANCY UPDATE CURRENT HVAC SYSTEM 15555 SW 98TH AVE A-3 TIGARD, OR 97224 REPLACE AGING UNITS WITH NEW CITY OF TGARD NO. OF STORIES � RMICW _R C_ DCC MP IANCS CONSTRUCTION TYPE 1-STORY INCREASE COOLING CAPACITY N Approved ACCESSIBLE o ROUTE u TYPE III - 1 HOUR OTC: 7 REMOVE UNSCREENED ROOFTOP UNITS AND REPLACE z SITE ANALYSISWITH GROUND-MOUNTED UNITS BEHIND FENCE AND Permit#: mem ENERGY PATH TOTAL SITE AREA 130,780 SF LANDSCAPING o Address: �dss t-� SEE ENERGY COMPLIANCE (E) BUILDING ;AREA 18,062 SF Suite #: CERTIFICATES (N) MECH PAD 103 SF By: DRAWING INDEX -- J 11` _ °°t LANDSCAPING LANDSCAPING (E) LANDSCAPING 34,387 SF (26%) Project Number: _ BUILDING CODES TOTAL LANDSCAPING 34,284 SF (26%) 501-4705-1903-0101 2019 OREGON STRUCTURAL TOTAL LOT COVERAGE 96,293 SF (74%) ARCHITECTURAL Plan Series: d SPECIALTY CODE MAX LOT COVERAGE 1116 3 S (85%) G0.0 COVER SHEET "' 1 F d ° ° d ^ ° ^ , e <• A1.0 REFERENCE FLOOR PLAN Property Number: d d , A 4. a. A1.1ROOF P A2.0 EL TIONS ELANDSCAPING < SW Park Sl ,� Sheet TitleA2.1 EVATIONS N < r y f O SNN az1921 COVER SHEET 3 r' swceg..°ods MECHANICAL SW Gaarde 51 SW McDonald St 'v M1-0 MECHANICAL FLOOR PLAN DEMOLITION THE ACTIVATION OF A DUCT M1.1 MECHANICAL ROOF PIAN DEMOLITION I SMOKE DETECTOR SHALL ACTIVATE A VISIBLE AND I eonirA sFarion M2.0 MECHANICAL FLOOR PLANS M2.1 MECHANICAL ROOF PLAN AUDIBLE SUPERVISORY f M6.0 MECHANICAL SCHEDULE AND DETAILS SIGNAL AT A CONSTANTLY ATTENDED LOCATION SWseulerst m P N F M6.1 MECHANICAL DETAILS r f a GMSC 606.4.1 w�`ury Swve osi `N( i k ` > F g �esssrsw ; 3 . _ ELECTRICAL / YB4hAfi RONH LL N EO.O ELECTRICAL LEGEND SW Durham Rd SW Durham Rd E3.0 ELECTRICAL FLOOR PLANS f aaW o T-ss rnoots� E3.1 ELECTRICAL ROOF PLAN Sheet: DURHAr M STATION n no LANDSCAPING ffCODE SUMMARY s CdOkPO/A'.= DURHAI.4 5P1 avAptoPk RC t' � N NO CHANGE IN AREA G0 . 0 PROPERTY LINE 665.9' NO CHANGE IN OCCUPANCY SITEPLAN SCALE . 1tt - 3Or-Ott NO CHANGE IN CLASSAROOFSOORPLAN VICINITY MAP CLASS E ROOF SPECIFIED/CLASS B REQ. PER 1505.1 (E)ACCESSIBLE ROUTES TO BUILDING Architect/ Engineer: V_ C0 (E) MOW STRIP TO REMAIN LO N MODIFY(E) LANDSCAPING L r AS REQUIRED EQMECHAIR DPFODR NEW (� N / 10'-0" MIN. 12'-10" V CO (E) FENCE TO BE REMOVED N N POWER /TRANSFORMER (E) SLATTED NEW REFRIGERANT LINES MEN < -� X 00 00 FENCE TO REMAIN CLASSROOM O (SEE MECHANICAL) L M O N O REPAIR CEILING AS REQUIRED W FENCE WITH SLATS MECH MECHANICAL NEW WALL PENETRATION CORR. TO MATCH (E) PAD 0 ENCLOSURE Q 0 M B O SEE MECHANICAL SEE G/A4.1 WOMEN -- A1.0 I..L BISHOP FURN. Stamp: ��D ARC HIGH COUNCIL ARCHIC SERVING RELIEF SOCIETY �J PRIESTHOOD AREA `� 1 STAKE PRESIDENT CLERK V A. ST RK CORR. 83 '"i JAN CLERK VRTLAND,OR OF OOC' CORR. FOYER WUJ\ CUST. Q04 N CLASSROOM ELEC. CLASSROOM ❑ O LIJ LU a) Q Q Z WOMEN MEN rn O co w M 0 0 z Q O � _ � Of CLASSROOM � W W { CLASSROOM PLATFORM CULTURAL CENTER LOUNGE CHAPEL 0 CLASSROOM o UUI, M U Q M x W li U V� F H � a WO CLASSROOM ❑ CLERK CLERK CLASSROOM FOYER CORR. 0 N O N Z CLERK C6 BISHOP BISHOP LA DRESS MEN BISHOP BISHOP LIBRARY CHILDRENS FONT CORR. Project Number: 501-4705-1903-0101 MEETING ROOM Plan Series: WOMEN ** CONCRETE PAD 21/4" I.D. SLEEVE BISHOP WWF OR#3 REBAR Property Number: @ MECHANICAL PAD 2" METAL 3/4" RADIUS FENCE POST TOOLED EDGE, TYP. Sheet Title:SLOPE2% MAX. AWAY FROM BUILDING GRADE CLASSROOM _ REFERENCE a _ FLOOR PLAN MECHANICAL — (E) FENCE TO REMAIN ENCLOSURE FURN. CLASSROOM — a — SEE MECH — — _— - I -1 I =1 I =1 11=1 11 I 1 I L 1 I 1=1 11=1 11=1 11=1 11=1 I M a -' AGGREGATE BASE UNDISTURBED NATIVE MATERIAL z _ Sheet: 111=�� #4 BAR AT TOP AND BOTTOM — —� 1 I I—I 1I- -111-111-111—I ' �. ,Illliilll=III Iii—ITI 111-1�1- A1 . 0 N s„ A FLOOR PLAN (FOR REFERENCE )/'1 MECHANICAL PAD 1/8" = V-0" @_1 1/2" = 1'-0" Architect/Engineer: MECHANICAL DEMO GENERAL NOTES oo " CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL L`7 CV EXISTING CONDITIONS AS IT PERTAINS TO EQUIPMENT i (` LOCATION, DUCT AND PIPE SIZE/ROUTING. (z N (E) GAS METER -i-i V MEN CLASSROOM MECHANICAL DEMO NOTES (D 4 CO 0 3 (E) CU-5 (FOR F-4) TT E CU-6 FOR AH-3 3 CORR. S (E)F-2 _ �/ / ( ) ( ) 0 1. RETAIN (E) FURNACE. REMOVE PORTION OF (E) SA Q V 0 0 WOMEN DUCT (SIZE AS LISTED) AT TOP DISCHARGE FOR C L m _0 INSTALLATION OF NEW DX COIL. REMOVE (E) FLUE Q C VENT AS REQ'D FOR INSTALLATION FOR COIL INSTALL; O O tCf SEE DETAIL 1/M6.0. (E) F-2O 2. (E) FURNACE TO BE REPLACED. DISCONNECT (E) GAS 0 REMOVE (E) REFRIGERANT LINES IN I ® & SA/RA DUCTWORK AND CONTROLS FOR NEW ATTIC/CEILING SPACE FOR REPLACEMENT IIII RELIEF SOCIETY (20"x16") IIIIFURN. BISHOP CONNECTIONS. REMOVE ALL (E) REFRIGERANT LINES III & REMOVE (E) FLUE. SEE DETAIL 2/M6.0 IIII SERVING (E)EF- O O 3. (E) CONDENSING UNIT AND ALL REFRIGERANT LINES HIGH COUNCIL ARCHIC IIII AREA ® T (E) F-1 1 TO INDOOR UNIT TO BE REMOVED FOR REPLACEMENT. PRIESTHOOD IIII (22"x20" 4. (E) COOLING COIL TO BE REPLACED. COIL SIZE AS Stamp: STAKE PRESIDENT CLERK (E)F-4 S IIII 5. RIEMOVE PORTION OF (E) SA/RA RISERS RIGHT PAN CORR. BELOW ROOF LINE & UP THRU ROOF TO REMOVED Seo 4- IIII (E)RT-2 O7 JAN. RTU. RETAIN PORTION BELOW ROOF FOR CONNECTION 17 84 "` TO NEW RELIEF PLENUM. 6. REPLACE (E) ASSOCIATED STAT IN SPACE. IIII 7. RETAIN (E) DIFFUSER FOR SPACE RELIEF. E) SA IN TO REMAIN IIII CORR. W, Nay IIII EXPIRES: 31DEC20 CUST. T T T II FOYER III 5 W CLASSROOM WOMEN MEN (20"x26") _ {{--+' > 'U'^^ W ELEC. I I r ❑ Q Q w N L Zi _ z Nr- CLERK REMOVE (E) 26X20 SA & 4 T S (E)AH-1 O � Z TRANSITION TO MAIN FOR NEW (E) AH-3 6 -2 I = U_ Q O COIL/DUCT INSTALLATION O I I I I 00 V H w CLASSROOM (E) F-402 v co co M 0 z UWj O FOR MECHANICAL ROOM ABOVE, SEE w � Of (E) ACCESS PANEL i M1 .O LL HIGH IN WALL ' I I Q W O W li i I � � w CLASSROOM I i PLATFORM CULTURAL CENTER LOUNGE CHAPEL (E)AH-3 i I S V) CLASSROOM i hN+M (E) ACCESS PANEL T F I a ►�" Q HIGH IN WALL i I I i t REMOVE (E) REFRIGERANT � t II LINES UP TO UPPER cu RT-1 ABOVE ROOF) I I I ( MECHANICAL ROOM ABOVE REMOVE (E) REFRIGERANT LINES UP TO UPPER I ❑ III I CLASSROOM CLASSROOM MECHANICAL ROOM ABOVE 1 1 I L- II I W O Ll I I CLERK CLERK 5 OS (E)AH-2 lil REMOVE (E) REFRIGERANT LINES IN — j I FOYER CORR. ATTIC/CEILING SPACE FOR REPLACEMENT I f — -✓ _ 7 7 CLERK (E) AH-2 DRESS. MEN I r1l, (78"x30") z Q n BISHOP BISHOP7 7 O 7 FONT I oREMOVE & RE-INSTALL � �BISHOP BISHOP LIBRARY I I I CORR. �26X14 SA TO ALLOW CHILDRENS r} ACCESS TO DOOR INMEETING ROOM REMOVE (E) REFRIGERANT THRU WALL. II CULTURAL CENTER WALL Project Number: RETAIN 2 OF THE 4 EXISTING WALL I ___ IIII 501-4705-1903-0101 BISHOP (E)AC-6Plan Series: PENETRATIONS FOR ROUTING OF NEW LINES IIII I T WOMEN it Property Number 03 (CU-4) I I I (S)(E)F-5 I REMOVE LINE low �(3 �T/ /�/ T /�/ III I I I SETSi FOR Sheet Title: CU-3 ) /� i I CLASSROO FE) F-5(D 601 I �I REPLACEMENT — — — ——— —�} I I 23") CLASSROOM (E) REFRIGERANT LINE SETS (1 PER I I MECHANICAL I I UNIT) FROM BELOW. REMOVE ALL LINES 1 MECHANICAL DEMO PLAN 03 (CU-2) ��/ F 1/� I I O (2 SETS PER UNIT IN MECHANICAL I FLOOR PLAN 22 ) SPACE) FEEDING (E) AIR HANDLERS. ii I� REMOVE LINE SETS FOR DEMOLITION SEE SHEET M2.0 FOR NEW COILS/LINES I I I REPLACEMENT & MAINTAIN PENETRATIONS THRU FLOOR .....�. FURN. FOR NEW LINE ROUTING i y 0(CU-1) REMOVE & RE-INSTALL i 4 (78"00") 26X14 SA TO ALLOW ACCESS TO DOOR IN CULTURAL CENTER WALL (E) AH-1 Sheet: 2 UPPER MECH . ROOM DEMO PLAN M1 .0 1 a =1 -o MConsulting Engineers M 1 . 0 2007 APortland, OR 9214 (S.E. Ash St I FA : (503)) 23470677 X IlVC.lI111I.MF1A—ENG.COM CONTACT: ANTONIO JOHNSON Architect/Engineer: T- 00 00 Lr� F1 N J L-- -- -- -- V CN I I4-0 N I I a U O O 0Q0 c� I I O -- -- -- -- - - - - -- - - - - -- - --- -- -- --- - - --- -- -- -- -- --- -- - - - - - I I I I I r- ---- -- - - - - --- --- -- i Stamp. ID PNFS SaG E� 17 84 I I I I deo°tr 2S I I � W. M�4 L— —— —- -- J❑ FLAT EXPIRES: 31 C20❑ r I I I I I I I I I LU > � o N <w v I I I 10 z � 0- w M U Q 0 �l'1J I L- -- - - -- - -- -- - _ - C I -- - - -- -I- - - - -- - -- -- -- -- -- - -� 00Lu i F-1I i LU rn O L- -- - -- - - - - -- - - -- - - -- --- - - -- ( Q z U) 3: I (E) RT-2 & CURB TO BE REMOVED FOR L �— O N Q NEW RELIEF HEAD. DISCONNECT CONTROLS AND SEE NEW WORK FOR COOLING CONTROL I Qn W O LO (D FUNCTION TRANSFER. RETAIN (E) SA/RA I V W w ~ I I DUCT RISERS BELOW ROOF FOR NEW I I I CONNECTIONS. REMOVE SA/RA BEYOND UP I I I TO UNIT I I I I I I I I J O IF xxA I I o (E) RT-1 & CURB TO BE REMOVED FOR NEW I RELIEF HEAD. DISCONNECT CONTROLS, AND oSEE NEW WORK fOR COOLING CONTROLaFUNCTION TRANSFER. RETAIN (E) SA/RADUCT RISERS BELOW ROOF FOR NEW CONNECTIONS. REMOVE SA/RA BEYOND UP C/�TO UNIT 0 � - -- ----- - - - -- --- - -- - - - - - - -I ❑ I TI -- -- -- -- -- ---- -- -J I I I I I I I I I I I I L -- --� t-- ---- -- - - - - - --- -- - - - --J I I I I I I J ❑ FLAT ❑ r - - - - - L - - -1 z I I I I I o I I Project Number: I 501-4705-1903-0101 Plan Series: Property Number: I I Sheet Tide: —— —— —— —— — — —— —— — — — — — — — — — — —— —— — — — — —— — — ——— —— —— — — — — — —— —— I I I MECHANICAL I I ROOF DEMO I I I I PLAN 1 MECHANICAL DEMO ROOF -o - - -- - -- - LJ Li Sheet: MConsulting Engineers M 1 . 1 2007 APortla�;d, OR 9214 (S E. Ash St I FAX: (503)) 2347 0548 677 INC.IPIIII.MM—ENG.COM CONTACT: ANTONIO JOHNSON Architect I Engineer: T_ � ROUTE REFRIGERANT LINES SET THRU WALL INTO CEILING SPACE (CORE MECHANICAL LEGEND DRILL WALL AS REQ'D). ROUTE TO NEW DX COILS FOR CC/F-1 CC/F-2 RF REPRESENTS LINE SET (2 LINES) �--+ - CU 3 BETWEEN UNITS (INDOOR/OUTDOOR) H-3 M6.1MEN MECHANICAL NOTES �x U) N CLASSROOM Cu CU A. RE-CONNECT (E) CONTROLS TO NEW FURNACE. SEE Q V O 3 F4 - Fl 3 ROUTE REFRIGERANT !1CORR.0 ? S SPECS FOR CONTROL DETAILS. L M6.1 Cu LINE SETS UNDER LAVE B. INSTALL NEW COOLING COIL IN EXISTING AIR HANDLER CO F3 , S CU M6.1 E ABOVE SAVE WOMEN WHERE OLD COIL WAS REMOVED. CONNECT NEW CD -� Q F2 ENCLOSURE TO (E) LINE AS REQ'D. O O J C. INSTALL NEW DX COOLING COIL AT DISCHARGE OF IRF FURNACE. PROVIDE TRANSITION FROM COIL TO (E) SA CC DUCT (SIZE LISTED). RE-CONNECT (E) CONTROLS. & F E AREAING ROUTE 3/4" CD THRU F2 C CD LINE TO (E) AS RED'D. SEE 1/M6.0 FOR DETAIL. HIGH COUNCIL E - - WALL TO (E) SERVICE SINK • " " SEE SPECS. (20 x18 ) D. CONTROLS: TRANSFER COOLING FUNCTION FROM ROUTE JEFRRANT T FURN. REMOVED ROOFTOP UNIT (AS LISTED) TO FURNACE Stamp: ARCHIL LINE SEON BISHOP NOTED. 18X18 RELIEF(DRAFT ROUTE RELIEF PRIESTHOOD ERA WALL TR CORR. E. REFRIGERANT PIPING COVER, SEE DETAIL 4/M6.1. STAKE PRESIDENT CLERK DUCT UPOOF TO RELIEF EAVE RELIEF SOCIETY F. ROUTE NEW REFRIGERANT LINES THRU (E) WALL Sac HEAD W/ BA DAMPER, SEE PENETRATIONS FROM REMOVED LINES. WHERE NEW �� 17 84 ROOF PLAN �� CLERK LINE SETS ARE INTRODUCED, CORE DRILL WALL / D (RT-2) REQ'D. SEE DETAIL 2/M6.1 FOR COVER ON VERTICAL 1 / RUNS ON WALL ' �Otr `qqb �q- S JAN G. CONNECT (E) SA/RA MAINS W/ SINGLE PLENUM AT nod W M�4� NEW RELIEF ON ROOF. SEE ROOF PLAN. H. INSTALL NEW DX COOLING COIL AT DISCHARGE OF EXPIRES: 31 DEC20 CONNECT NEW 14X14 FURNACE. PROVIDE TRANSITION FROM COIL TO (E) SA TO (E) AIN 4 CORR. FC C (SIZE LISTED) AS CONNECT AS REQ'D. RE-CONNECT (22"x20") (E) CONTROLS. & CD LINE TO (E) AS RED'D. SEE T T T FOYER 1/M6.1 FOR DETAIL. SEE SPECS. FOR REFRIGERANT w LINE INSULATION PROTECTION. \ W w G Q Q w v CLASSROOM ELEC. = N = O Oa w rn WOMEN MEN � ❑ � > Z 17' Q MECH. 136 W�, B ROVIDE NEW STAT FOR I — � f_n 00CC HEMOVED (E) DEVICE, IN 11A i UV � wF3 PACEp w rn; I Z to O 0 I I i I 0 w Lf)cn o CLASSROOM CONNECT NEW C LINE TO (E) CD LINE IN SPACE � a w 0 L F 2 w I I , w 4 6.0 CLASSROOM I I I I UPPER MECHANICAL ROOM ABOVE, SEE 1 PLATFORM CULTURAL CENTER I I LOUNGE I CHAPEL y CLASSROOM S I I O I � x I , I o 0 x a REFRIGERANT LINE SETS (2 PER UNIT) UP TO TO AHU'S ABOVE IN MECHANICAL ROOM I L — i CLASSROOM J W OCLASSROOM CLERK CLERK ` YILL � S FOYER RR. S V II I N II I N II I z I– DR S. CLERK a i i i I I ro BISHOP BISHOP i i i CC n I H- B BISHOP BISHOP LIBRARY ONT CORK. RE-CONNECT (E) Project Number: 26X14 SA TO (E), 501-4705-1903-0101 �! BISHOP ( 2I I Plan Series: CHILDRENS + MEETING ROOME F 40Q(2OX23)J Property Number:Sheet Trde: 3 1010�U� CLASSROOT S� CLASSROOM M6.1 CU ;; ❑ ❑ MECHANICAL (RT-1) 11 FLOOR PLANS 11 REFRIGERANT LINE 1 MECHANICAL PLAN _- FURN. SETS (2 PER UNIT) M2 4- 1/8"=V-00 E 4D(i.22) FROM BELOW THRU (E)( FLOOR PENETRATIONS. ii SEE 1/M2.0 i i i CC II I AH-1 B II ! II i II � ROUTE 3/4" CD LINE THRU WALL TO 1 Cu LANDSCAPE. CORE DRILL WALL AS 3 F6 ROUTE REFRIGERANT REQ'D. TERMINATE W/ DOWN TURNED Sheet: M6.1 CU LINE SETS UP ON ELBOW F5 WALL & INTO 2 UPPER MECHANICAL ROOM PLAN CEILING/ATTIC SPACE MConsulting Engineers M2 . 0 2007 S.E. Ash St. Portland, OR 97214 APHN: (503) 234-0548 FAX: (503) 234-0677 INC.www.MFIA-ENG.COM CONTACT: ANTONIO JOHNSON Architect/Engineer: r co LO N J L-- -- -- - - V � O7 I I 4-4 N I I U 0 0 i m C: 0 0 ca I I O - - - - - - - - - - - - - - -- - -- -- - - - - -- -- - - -- -- -- -- -- -- - - -- -- - - -- - 0- I I � I I r - - ---- - - -- --- ----- i Stamp: I t °PN�F1 RELIEF HEAD, SEE 3 I c�@o E I � 17 sa I ' I 1 I 1Pclr � , �9 � \ , I W to y L——— —— EXPIRES: 31 DEC2D ❑ FLAT ❑ r- -- I ' I ' I I I I I RELIEF HEAD W/ PLENUM, SEE M6.0 Q ::) X Z N N El ( (9 E� I I I = O a w rn / _ � Z jQ I L- - -- -- -- - - - - - - - - - - - - J-- ------------ --- -- 00 = = o I I 07 L 00 ly I ❑ I ' z °' O L-- -- --- - -- -- ----- - - - - ----- I _ � � o j I L j Q LU °o LO ff to 6 I I L1J 0 F- I i � LU I I L , I I I I I I J—J OoUw- - ----- --- --- --- _ _ _— _—_ _— -RELIEF HEAD W/ PLENUM, SEEOEl -- - - - -- - - --- -- - r - - - - - - - - - - ------ -- - -- -- - L -- - L- - -- -- - - - - - - -- - - - - -J I � I I � I I ❑ FLAT ❑ I I a I I I I a I ' I Project Number. I 501-4705-1903-0101 ' I Plan Series: I— — — —— —— — ——— — — — —— — — — p Y Pro ert Number: I Sheet Title: —— — — — — — — — — — -- - - -- -- -- - -- - - - ---- -- -- -- - - - - - - - - -- - - - - --- MECHANICAL- - - -- -- -- - -- - - - MECHANICAL ROOF PLAN I I I I I I I I 1 MECHANICAL ROOF PLAN ' ' 2.1 , s =, -o L 0 M - - -- -- -- -- �� -- -- ----LJ � Sheet: MConsulting Engineers M2 . 1 2007 OR 97214 PHN: (S E Ash St AN548 FAX:I(503)) 234— 0 77 INC.www.MM-ENG.COM CONTACT: ANTONIO JOHNSON Architect/Engineer: EXISTING AIR HANDLER - NEW CONDENSING UNITS CONDENSING UNIT REPLACEMENTS NEW FURNACE & CONDENSING UNIT T_ MARK CU CU CU ASSOCIATED FURNACE (EXISTING) F-1 F-2 F-3 F-5 F-6 SCHEDULE CID NUMBER AH-1 AH-2 AH-3 MARK NO. F-4 N NUMBER CU-F1 CU-F2 CU-F3 CU-F5 CU-F6 T_ i r � NOMINAL COOLING CAPACITY, TON 20 TON 20 TON 10 TON TOTAL CAPACITY (TONS) 5 5 3 5 5 TYPE VERTICAL EFFICIENCEY (EER) 11 11 11.2 AMBIENT AIR 95/67 vJ LOCATION MECHANICAL 136 'a-^-� V AMBIENT AIR 95/67 95/67 95/67 ENT AIR TEMP (DB/WB DEG. F) 81/63 MINIMUM OSA CFM SEE VENT SCHEDULE 4 N REFRIGERANT R410A R410A R410A SMOKE DETECTOR NO Q V O 0 REFRIGERANT R410A MIN/MAX OPERATING TEMPS 45/125 45/125 45/125 MIN FILTER AREA (DISP) - IN. SQ. 370 C:MIN/MAX OPERATING TEMPS 45/125 = Q m MAX PIPE LENGTH (FEET) * 85 105 55 MAX PIPE LENGTH (FEET) * 85 80 65 40 55 CFM 740 O O VOLTS/PHASE 208/3 208/3 208/3 MOCP/MCA 50/29.6 50/29.6 30/18.6 50/29.6 50/29.6 EXT. STATIC PRESS (IN.WC) 0.7 IZ --+ MOCP/MCA 90/70 90/70 45/33 WEIGHT 375 250 375 HP 0.2 O COMPRESSOR 2 2 2 BASIS OF DESIGN (MANUF/MODEL) LENNOX EL16XC1-060 LENNOX EL16XC1-036 LENNOX EL16XC1-060 HEATING INPUT CAPACITY (MBH) 66 0- CIRCUIT 2 2 2 ASSOCIATED COOLING COIL HEATING OUTPUT CAPACITY (MBH) 54.0 STAGE 2 2 2 VOLTAGE/PH 120/1 NEW COOLING COIL MARK CC-F1 CC-F2 CC-F3 CC-FS CC-F6 Stamp: WEIGHT (LBS) 900 900 500 BLOWER MOTOR AMPS 3.1 SYSTEM F-1 F-2 f-3 F-5 F-6 p MOCP PRS' BASIS OF DESIGN: LENNOX ELITE ELS24054D ELS240S4D ELS120S4D 15 a F COOLING COIL CFM 1,820 1,990 1,225 1,990 1,890 �` o t EXISTING AIR HANDLER - NEW COOLING COILS MAX AIR PRESSURE DROP ("H20) 0.4 UNIT WEIGHT (LB) 125 17 84 NEW COOLING COIL MARK CC/AH-1 CC/AH-2 CC/AH-3 REFRIGERANT TYPER410A BASIS OF DESIGN: LENNOX MH180UH07OP24A f SYSTEM EXISTING AH-1 I EXISTING AH-2 EXISTING AH-3 MARK NO. CU-4 �'� Otr 25,��°��� BASIS OF DESIGN (MANUF/MODEL) LENNOX CX38-62C LENNOX CX38-386 LENNOX CX38-62C 0 EXISTING COIL DIMENSIONS (LXH) 78" X 30" 39" X 32" TYPE CONDENSING UNIT 1N. Nay ENT AIR TEMP (DB/WB DEG. F) 81/63 NOTES: * NOT EQUIVALENT LINE LENGTH NOMINAL TONNAGE 2 EXPIRES: 31 EC20 LVG AIR TEMP (DB/WB DEG. F) 55/54 AMBIENT AIR 95 AIRFLOW (CFM) 8000 8000 3135 ENT AIR TEMP (DB/WB DEG. F) 81/63 COOLING (BTU/HR) 244,000 244,000 122,000 REFRIGERANT TYPE R410A W �w'�^1 w MAX. FACE VELOCITY (FPM) 500 MAX WEIGHT 200 /< vJ ZD < ? N MAX AIR PRESSURE DROP ("H2O) 0.4 ELECTRICAL (VOLT/PHASE) 208/1 N MCA/MOCP 14.6/25 = 0 0- > rn rZ- REFRIGERANT TYPE R410A U Q O NOTES: * NOT EQUIVALENT LINE LENGTH BASIS OF DESIGN: LENNOX ELXI6XC 024 00 _ � O (v� w LI) 00 LU CEILING Q z rn O CEILING (E) GAS FLUETO BE CEILING CEILING p REMOVED L.1_ p Q Lo SEE FLOOR PLAN FOR REFRIGERANT h w `r PROVIDE TRANSITION AS REQ'D i LINE ROUTING TO CONDENSING UNIT - - SEE FLOOR PLAN FOR REFRIGERANT �� - w 1 FOR CONNECTION OF NEW COIL � i 5 � r TO (E) SA DUCTWORK LINE ROUTING TO CONDENSING UNIT PVC VENT & COMBUSTION THRU ROOF, SEE REMOVE & (E) SA DUCTWORK TO BE 6.0 ii RE-INSTALL ii PORTION OF FLUE RE-CONNECT (E) REMOVED FOR INSTALLATION CONNECT UP E SA -n REMOVE (E) FLEX & CONNECT (E) SA OF NEW SYSTEM O FOR INSTALLATION DUCTWORK TO NEW " FLUE AS REQ'D I - DUCT/FLEX TO NEW UNIT DUCTWORK AS REQ'D FOR = = OF NEW COIL - INSTALLATION OF NEW = = COIL CASING AS I =� COOLING COIL SECTION SECTION REQ'D. PROVIDE � ja i y NEW FLEX NEW DX COIL SECTION. Y ATTACH TO TO (E) 'i W v r r� CONNECT NEW CD TO 0 FURNACE �,' (E) LINE FROM COIL x REMOVE (E) CONDENSATE DRAIN BELOW X1l i �i A SEE FLOOR PLAN FOR �� ELBOW AND UP TO FURNACE. RETAIN (E) i/�;�� RE-CONNECT/MODIFY A v V CONDENSATE DRAIN ROUTING BELOW ELBOW FOR NEW CONNECTION r ; , (E) GAS LINE TO NEW v ` (E) FURNACE TO REMAIN /�/�/�i FURNACE AS REQ'Dd (> W DISCONNECT E GAS �� ; , FOR FURNACE REMOVAL CONDENSATE NEUTRALIZATION CHAMBER DEMO NEW --l - ---� v� 4-t-L (E) FURNACE TO BE ROUTE TO (E) FLOOR DRAIN W NOTES: REMOVED FOR REPLACEMENT DISCONNECT (E) RA FOR FURNACE &4 / RE-CONNECT (E) RA 1. WORK SHOWN FOR FURNACES F-1, 2, 5 & 6. REMOVAL DUCT/FLEX TO NEW UNIT 2. (E) FLUE CONFIGURATION MAY DIFFER AT EACH LOCATION. FURNACE DEMO NEW FURNACE INSTALLATION CONTRACTOR TO VERIFY EACH PRIOR TO WORK. 1 E FURNACE W NEW COOLING COIL 2 FURNACE NEW F- 4 DETAIL 6. 0 SCALE: DETAILM 6. 0 SCALE: DETAIL CONCENTRIC ALUMINUMALUMINUM COMBINATION SHEET METAL GAS VENT AND ENCLOSURE ENCLOSURE COMBUSTION AIR o z a �— BIRDSCREEN BIRDSCREEN � ALL AROUND FULL SIZE BACKDRAFT DAMPER ALL AROUND SEALED STORM COLLAR �— ANCHOR RELIEF HEAD ANCHOR RELIEF HEAD COUNTER- FLASHING. i i FLASHING Project Number: CAP TO CURB COUNTER- FLASHING. 501-4705-1903-0101 COUNTER FLASHING CAP TO CURB MIN. 18" COUNTER FLASHING � � Plan Series: o _ __ _ _ o _ ___ _ _ ROOF i * REMOVABLE FLASHING RELIEF GRILLE OR REMOVABLE FLASHING Property Number: _ __ 0 1 RELIEF DUCT. SEE RELIEF GRILLE OR FACTORY CURB TO FLOOR PLAN FOR 1 RELIEF DUCT. SEE 12„ MATCH ROOF SLOPE SPECIFIC FACTORY CURB TO SPOOR IC LAN FOR Sheet Title: ROOF APPLICATION MATCH ROOF SLOPE APPLICATION ROOF SUPPORT FOR SHEETMETAL SLEEVE IL-- MECHANICAL SHEETMETAL SLEEVE SCHEDULE & EXISTING ROOF STRUCTURE EXISTING ROOF STRUCTURE APPROX. 35X16 PLENUM TO ALLOW DETAILS SA/RA DUCT CONNECTIONS PVC COMBUSTIO FULL SIZE BACKDRAFT DAMPER AIR VENT EXTEND (E) SA/RA DUCTS TO NEW PLENUM \ PVC FLUE VENT RELIEF DUCTED TO CEILING DIFFUSER IN SPACE, SEE FLOOR PLAN NOTES: 5 COMBINATION VENT COMBUSTION AIR 1. SEE ROOFING DETAILS FOR ADDITIONAL FLASHING REQUIREMENTS. NOTES: -�- -- Sheet: 1. SEE ROOFING DETAILS FOR ADDITIONAL FLASHING REQUIREMENTS. M6.0 SCALE: DETAIL 3 RELIEF HEAD 4RELIEF HEAD W PLENUM M6.0 SCALE: DETAIL M6.0 SCALE: DETAIL Consulting EnginM6 . 0 2007 and, OR 9214 PHN: (S E Ash St Z .... 48 AX:I(503 234-7060577 23470677 INC.WWII.MFIA-ENG.COM CONTACT: ANTONIO JOHNSON Architect/Engineer: T_ co Lr) N CO !� (E) SA MAIN TO v) (3) (V REMAIN FOR NEW CONNECTION Q .� x O SEE FLOOR PLAN FOR 0 Q REFRIGERANT LINE m ROUTING TO Q O CONDENSING UNIT Q --- I ,�----T UNISTRUT PIPE SUPPORT, ATTACH t CONNECT NEW 14X14 TO WALL Q LINED SA TO (E) SA MAIN In 7 i ATTACH ANGLE TO WALL REMOVE & FLEX W/ S.S. SCREWS ® 12" o/c. REMOVE (E) 26X20 SA & RE-INSTALL RE-CONNECT (E) TRANSITION TO (E) MAIN FOR PORTION OF FLUE NEW COIL INSTALLATION FLUE AS REQ'D ""~ 18 GA S.S. 1"X1" ANGLE Stamp FOR INSTALLATION I IOF NEW SECTION COIL CONNECT NEW S� DPN �rJ DX COIL CASING I I I I TORQUE DRIVEN PAN HEAD, S.S. TO (E) FURNACE SHEET METAL SCREW ® 12" o/c. I I I I If 'PC ✓V(Y n SEE FLOOR PLAN FOR O� W. CONDENSATE DRAIN ROUTING 18 GA. PAINTED SHEETMETAL COVER (E) FURNACE TO REMAIN i TO EXTEND FROM CEILING SURFACE EXPIRES: 31DEC20 TO VERTICAL CHASE UNLESS NOTED - -- -- OTHERWISE DEMO NEW PIPE CLAMP. OMIT INSULATION ® CLAMP ONLY LUw w PROVIDE GALV. PROTECTION ® CONNECTION / w � FURNACE F-3 ONLY (D z(D z N ON 0- ,LLJ °' 1 E FURNACE W NEW COOLING COIL 2 VERTICAL PIPE DROP COVER 2 L) Q o M 6. 1 M 6.1 SCALE: DETAIL Q7oo L w w SCALE: DETAIL z w rnof Q NLL (r) 0 Q w O `un C¢7 '^ UJ � ~ w h O L: U H+•� A , 18 GA. GALV. CAP W/ SLOPE Vp4 ON CEILING OF MECHANICAL a V ROOM. INSTALL ABOVE CEILING UNISTRUT 1-5/8" CHANNEL, TYP. W 48" CLEAR IN ALL OTHER LOCATIONS GASKETED S/M ABOVE UNIT EXTEND CHASE SCREW (TYP.) TO BOTTOM OF w O SOFFIT F—� CORE DRILL. COORD. PENETRATION W/ zo HEAT PUMP WALL STRUCTURE (BOND BEAMS) DEVICES ON WALL INSIDE AND ARCH. PENETRATE 48" TO 72" AFF. SEE 2/M6.0 FOR UNISTRUT P2626, TYP. COVER AT DROP AT WALL UNISTRUT 1-5/8" Ly' EXTERIOR WALL CHANNEL, TYP. 12" MIN. VERFIY a PER o MANUFACTURERS N REQUIREMENTS Q SEE 4/M6.1 FOR UNISTRUT P2072AREFRIGERANT PIPING (TYP.) o HORIZONTAL BASE, TYP. _:�Ll COVER 8" MIN - - ALL Project Number: 501-4705-1903-0101 SIDES RIF RF RF (E) SLAB Plan Series: 3" MIN. j NOTES. Property Number: REFRIGERANT LINES - SIZE ** - - PER MANUFACTURER REQUIREMENTS. ROUTE TO 1. INSTALL SUPPORTS ® 48" 0/C. Sheet Title: SLAB PER GRADE ASSOCIATED DX COIL 2. ELEVATION AND WIDTH TO MATCH SITE PAD /SLAB CONDITIONS. ARCHITECTURAL MECHANICAL 3 CONDENSING UNIT DETAIL 4 REFRIGERANT PIPING DETAIL DETAILS SCHEDULE & M6.1 SCHEMATIC M6. 1 SCALE: DETAIL Sheet: MConsulting Engineers M6 . 1 2007 (S.E. Ash St Portd, OR 97214 20548 AI FAX:I(503)) 34 677 INC.WWW.MFTA-ENG.COM CONTACT: ANTONIO JOHNSON Architect/Engineer: ELECTRICAL SYMBOL LIST CIO N M U N U) N LIGHTING SYMBOLS POWER SYMBOLS ONE-LINE DIAGRAM SYMBOLS ABBREVIATIONS v ryM0 � 171 LIGHT FIXTURE, RECESSED RECEPTACLE, DUPLEX +18" A.F.F. PANEL ELECTRICAL DISTRIBUTION PANELBOARD (MLO) 'A' LIGHT FIXTURE TYPE (SEE FIXTURE LIST) = < W m LIGHT FIXTURE, RECESSED - EMERGENCY �TR RECEPTACLE, DUPLEX, TAMPER RESISTANT +18" A.F.F. q' A.F.F. ABOVE FINISHED FLOOR 0 0 M LIGHT FIXTURE, SURFACE MOUNT dW.P. RECEPTACLE, WEATHER-RESISTANT DUPLEX, WEATHER-PROOF COVER A.F.G. ABOVE FINAL GRADE If 0 LIGHT FIXTURE, SURFACE MOUNT - EMERGENCY RECEPTACLE, QUAD +18" A.F.F. `0� ELECTRICAL DISTRIBUTION PANELBOARD (MCB) A.F.I. ARC FAULT INTERRUPTER 0 PANEL �—a LIGHT FIXTURE, STRIP RECEPTACLE, QUAD, EMERGENCY +18" A.F.F. !A SUB-FEED CIRCUIT BREAKER A.T.S. TRANSFER SWITCH, AUTOMATIC L.L �« LIGHT FIXTURE, STRIP - EMERGENCY RECEPTACLE, QUAD, EMERGENCY +6" ABV COUNTER C CONDUIT O DOWNLIGHT FIXTURE, RECESSED RECEPTACLE. DUPLEX +6" ABV COUNTER ypU 3 C.O. CONDUIT ONLY O- QI DOWNLIGHT FIXTURE, RECESSED, WALLWASH RECEPTACLE, DUPLEX +18" A.F.F. (ONE OUTLET SWITCHED) CIRCUIT BREAKER (TRIP RATING & POLES AS INDICATED ON PLAN) CAN CABLE TELEVISION Stamp: ® DOWNLIGHT FIXTURE, RECESSED - EMERGENCY LPs RECEPTACLE, DUPLEX, UPS +18" A.F.F. 200 3 CB CIRCUIT BREAKER p PROF SERE fs LIGHT FIXTURE, WALL MOUNT UPS�� RECEPTACLE, DUPLEX, UPS +6" ABV COUNTER .__, . CCN CLOSED CIRCUIT TELEVISION ��� ANG INff,P s%y E T ELECTRONIC TRIP CIRCUIT BREAKER 16s97 :r 0 LIGHT FIXTURE, CEILING MOUNT RECEPTACLE, DUPLEX, PEDESTAL MOUNT C.T. CURRENT TRANSFORMER O RECESSED LIGHT FIXTURE, WALL MOUNT O RECEPTACLE, DUPLEX, FLUSH FLOOR MOUNT E EMERGENCY OREGON MAIN SWITCH (RATING & POLES AS INDICATED ON PLAN) g�',�� r�, K) LIGHT FIXTURE, WALL MOUNT ®DR 0 RECEPTACLE, SPECIAL (COORDINATE WITH EQUIPMENT SERVED) 200q Wq E.L. EMERGENCY LIGHT §tp'L ® LIGHT FIXTURE, WALL SCONCE _HT _ SNOW MELT CABLE \3P -RK1 E.L.C. EXTERIOR LIGHTING CONTROL EXPIRES 12-31- w .9.90 LIGHT AS INDICATED ON PLAN . . w \J LIGHT FIXTURE, TRACK W/ HEADS AS SHOWN ON PLAN 1 .. FACP FIRE ALARM CONTROL PANEL ® EXIT SIGN, UNIVERSAL MOUNT, W/ DIRECTIONAL ARROW ® ELECTRIC VEHICLE CHARGING STATION 'CFUSE (RATING & CLASS AS INDICATED ON PLAN) G.F.I. GROUND FAULT INTERRUPTER EXIT SIGN, WALL MOUNT, +8'-0" A.F.F. © MAGNETIC CONTACTOR l J GND GROUND W ' ' 1 EMERGENCY LIGHT W/ BATTERY PACK, +8'-0" A.F.F. ® RELAY TRANSFORMER (RATING AS INDICATED ON PLAN) H.I.D. HIGH INTENSITY DISCHARGE \ U) W \J J LU w- FLOOD LIGHT ® TIME CLOCK CONTROL HP HORSEPOWER Q Of � N y � M AREA LUMINAIRE O PUSHBUTTON STATION I.G. ISOLATED GROUND = 0 N W rn y.� O > > z M AREA LUMINAIRE W/STANDBY LAMP OO JUNCTION BOX I R INFRARED = O Q O AREA LUMINAIRE, WALL MOUNT OO THERMOSTAT 1KO9 FUSE (RATING & CLASS AS INDICATED ON PLAN) JB JUNCTION BOX 00 -'^L = 4 v W AREA LUMINAIRE, POLE MOUNT ❑ TRANSFORMER LCP LIGHTING CONTROL PANEL 7 w M O L Cl) ® LIGHT FIXTURE, DAYLIGHT DIMMING ( DIMMING ZONE 1 ) ❑' DISCONNECT, NON-FUSED �—GROUND GROUND SYSTEM (SIZE AS INDICATED ON PLAN) MCB MAIN CIRCUIT BREAKER Q z I C0 0 y LL DISCONNECT, FUSED MLO MAIN LUGS ONLY 0 `o < ❑p REMOTE LED EMERGENCY BATTERY Q W 0 Lo 6 ® ELECTRICAL CONNECTION WATER PIPE GROUND ELECTRODE M.T.S. TRANSFER SWITCH, MANUALLU LO ELECTRICAL CONNECTION, SINGLE MOTOR (N) NEW LIJ ELECTRICAL CONNECTION, MULTI-MOTOR ® TRANSIENT VOLTAGE SURGE SUPPRESSOR N.I.C. NOT IN CONTRACT ELECTRICAL DISTRIBUTION PANEL, SURFACE N.L. NIGHT LIGHT SWITCH SYMBOLS a MISCELLANEOUS PANEL, RECESSED . UTILITY METER & METER BASE OL OVERLOAD $ SWITCH, SPST +48" A.F.F. `----1O.L.C. OFFICE LIGHTING CONTROL r FLUSH FLOOR BOX (W/ DEVICES AS SHOWN ON PLAN) r`1 $z SWITCH, DPST +48" A.F.F. = ELECTRICAL DISTRIBUTION PANEL, RECESSED C.T. UTILITY METER CURRENT TRANSFORMER P POLE $3 SWITCH, 3-WAY +48" A.F.F. P.A. PUBLIC ADDRESS W F� $4 SWITCH, 4-WAY +48" A.F.F. ELECTRICAL CONNECTION, FIRE/SMOKE DAMPER 0 h�✓+i FSD O1 FEEDER NO. (SEE FEEDER SCHEDULE) zPC PARTIAL CIRCUIT $K SWITCH, KEYED +48" A.F.F. PH PHASE o V $JK SWITCH, 3—WAY KEYED +48" A.F.F. PRI PRIMARY 0 U $Lv SWITCH, LOW—VOLTAGE OVER RIDE +48" A.F.F. R. 0- REMOTE TELEMETRY UNIT 0- V W $p 0-10V LED DIMMER, TOGGLE ON/OFF WITH PRESET —g\ WIRING SYMBOLS NOTATIONS SEC SECONDARY �j SCCR SHORT CIRCUIT CURRENT RATING Q1 W � EMERGENCY BYPASS RELAY PANEL & CIRCUIT NUMBER#1� DRAWING NOTE T.V.S.S. TRANSIENT VOLTAGE SURGE SUPPRESSOR W 0 HOMERUN TO PANEL© U.G. UNDERGROUND F�PHOTOCELL, CONTACT CLOSURE 2 CONDUCTOR SIZE (IF OTHER THAN #12) E3 DETAIL REFERENCE: TOP=DETAIL NO., BOTTOM=SHEET NO. U.O.N. UNLESS OTHERWISE NOTED ©DZ1 PHOTOCELL, 0-10V DAYLIGHT DIMMING ( DIMMING ZONE 1 ) PHASE CONDUCTOR VFD VARIABLE FREQUENCY DRIVE NEUTRAL CONDUCTOREF Q GROUND CONDUCTOR OCCUPANCY SENSOR, INFRA-RED, WALL +48" A.F.F. MECHANICAL EQUIPMENT MARK NO. (SEE EQUIPMENT SCHEDULE) W WIRE >I @2 OCCUPANCY SENSOR, DUAL TECH, CEILING / CONCEALED CONDUIT AAA XRAY EQUIPMENT N0. (SEE XRAY VENDOR SCHEDULE) W.G. WIRE GUARD /1-1/4"C W.P. WEATHERPROOF os OCCUPANCY SENSOR, DUAL TECH, CORNER \ W.T. WATERTIGHT 3 ( � CONDUIT SIZE (Dos4 XRAY ROOM DRAWING NOTE X.P. EXPLOSION PROOF OCCUPANCY SENSOR, ULTRASONIC, CEILING 11 CONDUIT (UNDER SLAB OR FLOOR) - - - -3 CONDUIT, STUBBED & CAPPED o z 0 NOTE: SOME OF THE SYMBOLS AND ABBREVIATIONS ON THIS LIST MAY NOT APPLY TO THIS PROJECT. Project Number: 501-4705-1903-0101 EQUIPMENT SCHEDULE Plan Series Property Number: NO. EQUIPMENT NAME HP/KW VOLTS PH AMPS CONDUIT WIRE GND CIRCUIT N OT E S : CU—F5 COND. UNIT F5 1 208 1 29.6 MCA 1" 6 10 1 1 # # 0 0 RE-CONNECT TO EXISTING CIRCUITS. PROVIDE 50A/2P BREAKER. Sheet Tide: CU-F6 COND. UNIT F6 1 208 1 29.6 MCA 1" #6 #10 0Q2 RE-CONNECT TO EXISTING CIRCUITS. PROVIDE 30A/2P BREAKER. ELECTRICAL -_ _ CU-AH1 COND. UNIT AH1 208 3 33 MCA 1" #6 #10 M-1,3,5 LEGEND CU-AH2 COND. UNIT AH2 208 3 33 MCA 1" #6 #10 M-7,9,11 Q RE-CONNECT TO EXISTING CIRCUITS. PROVIDE 6OA/3P BREAKER. CU-1`3 COND. UNIT F3 208 1 18.6 MCA 1/2" #10 #10 Q2 ® NOT USED. CU-AH3 COND. UNIT AH3 208 3 37 MCA 1" #6 #10 O3 - Q PROVIDE 50A/2P BREAKER. CU-F1 COND. UNIT F1 208 1 29.6 MCA 1" #6 #10 M-13,15 Q CU-F2 COND. UNIT F2 208 1 29.6 MCA 1" #6 #10 M-17,19 05 COORDINATE WITH MECH FOR EXACT LOCATION OF EQUIPMENT. Sheet: E0 . 0 Architect I Engineer: r CID NOTES : ti CU O1 EXISTING MECHANICAL EQUIPMENT TO BE REPLACED. DISCONNECT CO F3 AND PREP FEEDER FOR RECONNECTION. U) MEN W N LL CLASSROOM 22 EXISTING MECHANICAL EQUIPMENT TO BE REPLACED. DISCONNECT x 0 CU CU AND PROVIDE NEW CONNECTION AS SCHEDULED. V 0 �}' CORR. ' WOMEN O3 EXISTING MECHANICAL EQUIPMENT TO BE REMOVED. DISCONNECT Q ® ® AND DEMO FEEDER BACK TO BRANCH PANEL, MAKING ITS O 0 M BREAKER SPARE. v— CU CU F4 F2 BISHOP FURN. Stamp: HIGH COUNCIL ARCHIC SERVING CORR. �RFO PRofe PRIESTHOOD AREA � �NOINEE,9 oy STAKE PRESIDENT CLERK SS 16,597 INIP RELIEF SOCIETY JAN. CLERK OREGON Y 9°} CORR. EXPIRES 12-31-2021 FOYER W W 0 Q Q LU I- MECH. 136 CLASSROOM ELEC. IY = N = O > > Z LJ WOMEN MEN ❑ I— _ g Q o t ❑ rn Ut T 00 LJ 0 z U) O (E) PANEL V U- CLASSROOMui.i O uo Q W 0Y `n C� I I � ~ F LU 4 1 I I I I I I CLASSROOM I j I I I I I I PLATFORM CULTURAL CENTER i LOUNGE i CHAPEL H I I I WO CLASSROOM I ' x I I o v I -, 0 s a UV� E I W44 CLASSROOM OCLASSROOM ❑ F� I CLERK CLERK FOYER RR. 0 II I N MEN DR S. FBISHOP BISHOP BISHOP u I II I CORR. I I I BISHOP BISHOP LIBRARY ONT Project Number. 501-4705-1903-0101 II I I I Plan Series: CHILDRENS MEETING ROOM WOME i Property Number: .< II I Sheet Title; II 1 CLASSROOM CU O CLASSROOM AH-1 CU O I� ELECTRICAL II I FLOOR PLANS II I 1 ELECTRICAL PLAN FURN. II I II I II I II I II I II I II I II I II I II I CU ' II I F6 Sheet: CU F5 E3 . 0 Architect/Engineer: co LO N J L-- -- -- -- V -- - - -- -- L_-- J U N a U 0 L M I I O Q O M I I 0 -- - - - - -- --- -- -- -- - - - --------- --- -- -- - - - - - - - - - -- - - - - -- - I I I I I - - - -- -- --- --- — — — — — I Stamp: I v �pG 1 NFfjr i I i SSFPED PROF s� 16,597 ( I I I OREGON I Y20. J EXPIRES 12 31-2021 L - - � ❑ FLAT ❑ r- -- D I I LU I I I ---� - -- -- -- -- -- -- - - --- -- --- - i I > w o I I I I Q (D z r ❑ ❑ I I I = rN- 0 > j cn = 2 ¢ o I 3 I ❑ I L - - - -- - - - - --- ❑ II LU z 3: O j I T L Q W LL LO O L 2 L I I (D 'JJ I L � I I I I ' I o JF x UU W O -- ---------- -- - --- -- -- -- - -- - -- I O I I I I I I I I I I I I I I I L- - - � E-- -- ----- -- --- -- ------ --- - I I I I I ❑ FLAT ❑ I o I I Q I I � I Project Number: I 501-4705-1903-0101 Plan Series. I I , Property Number: I I , I i _ Sheet Title: ——— —— — —— ——— — —— — —— — —— — ———— —— —— ——— ——————— — — ——— —— — — — — — I I I ELECTRICAL I I ROOF PLAN I I I I I I I I 1 ELECTRICAL ROOF PLAN I0 Li L I Sheet: E3 . 1