Plans (55)
M EC2019 -00759 ( 2/2 ) OFFICE COPY � � OCT 2 9 2019 CITY OF 7IGARLD NOTE:NOT ALL ORABBREVIATIONS HVAC LEGEND PROJECT. REFER TBDETAI SAND NOITETNS ARE APPLICABLE TOSFOR MOUNTING H IGHTSHiS HVAC DRAWING LIST ����`���1PNOFFssf r)!NIGGiWSlc)1v GENERAL DUCTWORK 10373 AN ABOVE d ¢ DIGITAL SIGNATURE FO FAIL OPEN SHEET o 0 AC AIRCONDITIONING _ `- NUMBER SHEET NAME o o a s ottecoN FPI FINS PER INCH SYMBOL DESCRIPTION SYMBOL DESCRIPTION ACCEPT ACCEPTANCE FPM FEET PER MINUTE RH RELATIV>=HUMIDITY __ '- ACU AIR CONDITIONING UNIT FPS FEET PER SECOND RHC REHEAT COIL NEW WORK ®AD/AP ACCESS DOOR/ACCESS PANEL FSD E M0.00 MECHANICAL LEGEND AND ABBREVIATIONS X X AD ACCESS DOOR RHT ADD ADDITION FT FOOOTOT OOR RADIANT HEATER FM0.01 BASIS OF DESIGN AND TABULATED DATA X X RENEWS: 06-30-2020 R FEET DAMPER RM ROOM (E) EXISTING WORK TO REMAIN AF AFTER FILTER G GAS RPM REVOLUTIONS PER MINUTE FLEXIBLE CONNECTION M0.02 SCHEDULES X X AFF ABOVE FINISHED FLOOR RS REFRIGERANT SUCTION .-----------.- -(D) EXISTING WORK TO BE REMOVED M0.03 SCHEDULES X X X AFMS AIR FLOW MEASURING STATION GA GAUGE,GAGE GAL GALLONS RTU ROOFTOP UNIT F FUTURE WORK � M0.05 VENTILATION CALCULATIONS X X AFUE ANNUAL FUEL UTILIZATION EFFICIENCY S SUPPLY OR SLOPE GC GAS COCK OR GENERAL CONTRACTOR O DUCT RUNOUT TO DIFFUSER M2.00 BASEMENT-HVAC PLAN X X AG AIR GAP GALV GAS COCK O SA SUPPLYAIR �� RELOCATE EXISTING F�oeawu>� '"LN6EFrvC SNGEsp' ---------- �� fMt'F�ti.p.we.re AN AUTHORITY HAVING JURISDICTION SCFM CFM, STANDARD CONDITIONS R RECTANGULAR DUCT SIZE M2.01 GROUND FLOOR-HVAC PLAN X X X AHU AIR HANDLING UNIT GLV GLOBE VALVE SD SMOKE DAMPER 12x6 M2.02 SECOND FLOOR-HVAC PLAN X X GN GENERAL NOTE AMB AMBIENT SEER SEASONAL ENERGY EFFICIENCY RATING CLCENTER LINE (WIDTH x DEPTH IN INCHES) M2.03 THIRD FLOOR-HVAC PLAN X X X GPM GALLONS PER MINUTE A AMPERE SEN SENSIBLE - GND GROUND ROUND DUCT SIZE M2.04 FOURTH FLOOR-HVAC PLAN X X X AP ACCESS PANEL SF SUPPLY FAN OR SQUARE FEET POINT OF CONNECTION OR 18e DIAMETER IN INCHES APPROX APPROXIMATELY GV GATE VALVE SHC SQUARE HEAD COCK ® ( ) M2.05 ATTIC- HVAC PLAN X X 01 POINT OF DISCONNECTION H HEIGHT M2.09 ROOF-HVAC PLAN X X r 01 ARCH ARCHITECT SIU SPLIT INDOOR UNIT OVAL DUCT SIZE HB HOSE BIBB 1 24x129 M5.01 SUPPLY DUCTWORK RISER DIAGRAMS X X HC HEATING COIL ARI AMERICAN REFIRGERATION INSTITUTE SOU SPLIT OUTDOOR UNIT DETAIL i, DRAWING M-1 (WIDTH x DEPTH IN INCHES) M-1 AS AIR SEPARATOR SP STATIC PRESSURE M5.02 EXHAUST DUCTWORK RISER DIAGRAMS X X AUTO AUTOMATIC HD HEAD SPD SPLITTER DAMPER M6.01 ENLARGED PLANS X X X HOR HORIZONTAL AUX AUXILIARY SPEC SPECIFICATIONS DUCT THROUGH BEAM PENETRATION M6,02 ENLARGED PLANS X , , B BOILER HP HIGH PRESSURE SQ IN SQUARE INCH _r PAY HP HORSEPOWER A T M901 MECHANICAL DETAILS X X � �' BED BACK ELO DRAFT DAMPER ST STRAINER OR SOUND TRAP M-1 SECTION A, DRAWING M-1 BEL BELOW HP HEAT PUMP STD STANDARD M902 MECHANICAL DETAILS X X � L 3 DUCT OFFSET(RISE OR DROP} BHP BRAKE HORSEPOWER HR HOUR(S) STRUCT STRUCTURAL M903 MECHANICAL DETAILS X IX BOD BOTTOM OF DUCT HRU HEAT RECOVERY UNIT SV STEAM VENT VD RVD VOLUME DAMPER OR REMOTE VOLUME DAMPER M904 MECHANICAL DETAILS X BOP BOTTOM OF PIPE HS HUMIDITY SENSOR T THERMOSTAT OR THERMOMETER HTR HEATER M905 MECHANICAL DETAILS X X HV HOSE VALVE BFP BACKFLOW PREVENTER TCP TEMPERATURE CONTROL PANEL FD SD_ FS FIRE, SMOKE OR FIREISMOKE DAMPER ttG BSMT BASEMENT jDH TOTAL DYNAMIC HEAD 1 BTU BRITISH THERMAL UNIT HVAC HEATING,VENTILATING AND AIR CONDITIONIN tEMP TEMPERATURE M_1 ELEVATION 1,DRAWING MA HX HEAT EXCHANGER SUPPLY DUCT UP BTUH BTU PER HOUR TFA/TFB TO FLOOR ABOVE/BELOW �-� BV BALL VALVE OR BALANCING VALVE HZ FREQUENCY(HERTZ) TI TENANT IMPROVEM6NTL�^•1 � SUPPLY DUCT DOWN BYV BUTTERFLY VALVE ID INSIDE DIAMETER TRG TRANSFER GRILLE EXH RISER IDENTIFICATION ---- ®FFILr. COPY C COMMON,CONDENSATE OR CONDUIT IN INCH(ES) TS TEMPERATURE SENSOR 1 EXHAUST#1 EXHAUST DUCT UP DUCTWORK INPLV INTEGRATED PART LOAD VALUE CA CONTROL AIR TSP TOTAL STATIC PRESSURE EXHAUST DUCT DOWN CAP CAPACITY JB JUNCTION BOX TT TEST TAP OR TEST TEE H:p EQUIPMENT IDENTIFICATION RECTANGULAR OR ROUND SUPPLY KWH KILOWATT HOUR CAV CONSTANT AIR VOLUME KW KILOWATT TXV THERMAL EXPANSION VALVE TAG NECK SIZE CFM L LENGTH CEG CEILING EXHAUST GRILLE (TYP) TYPICAL 1 HEAT PUMP UNIT#1 � RETURN DUCT UP DIFFUSER OR REGISTER(SEE CER CEILING EXHAUST REGISTER LAT LEAVING AIR TEMPERATURE )SCHEDULE U HEAT TRANSFER COEFFICIENT 4-WAY THROW CFF CAP FOR FUTURE LBS POUNDS UC UNDER CUT DOOR RETURN DUCT DOWN UNLESS INDICATED OTHERWISE, CD CFM CUBIC FEET PER MINUTE LDB LEAVING DRY BULB EXAMPLE;UG UNDERGROUND 1 KITCHEN EQUIPMENT TAG Z � _ CFS CUBIC FEET PER SECOND LF LINEAR FEET UH UNIT HEATER 8 CROSS SECTION OF SUPPLY DUCT SBUX12-400 REFERS TO TAG SB CH COVE HEATER LWB LEAVING WET BULB UON UNLESS OTHERWISE NOTED # KEYED NOTE WITH 12'X12' NECK AND 400 CFM CL CENTERLINE V VENT OR VOLUME OR VELOCITY CROSS SECTION OF EXHAUST AIR DUCT LWT LEAVING WATER TEMPERATURE co Q CLG CEILING M MOTOR VAV VARIABLE AIR VOLUME 15o DIRECTION OF TRANSFER AIRFLOW(150 CFM) ® TAG NECK SIZE CFM RECTANGULAR OR ROUND N = CO CLEANOUT MA MIXED AIR BD VOLUME DAMPER 0 CROSS SECTION OF RETURN AIR DUCT EXHAUST GRILLE OR REGISTER COL COLUMN VEL VELOCITY 78°F 78 DEGREES FAHRENHEIT SEE SCHEDULE �' !� MAD MIXED AIR DAMPER ( ) J COMP COMPRESSOR VERT VERTICAL O CROSS SECTION OF ROUND DUCT N � MAX MAXIMUM RECTANGULAR OR ROUND RETURN Z I� CONC CONCRETE VFD VARIABLE FREQUENCY DRIVE CO MBH THOUSAND BTU PER HOUR Z TAG NECK SIZE-CFM GRILLE OR REGISTER SEE Q COND CONDENSATE VFM VENTURI FLOW METER DUCT ELBOW WITH TURNING VANES SCHEDULE CONN CONNECTION MC MINIMUMCRCUIT MPACIT VOL VOLUME _ ( O CONT CONTINUATION MCA MINIMUM CIRCUIT AMPACITY VTR VENT THROUGH ROOF ) of MCC MOTORIZED CONTROL CENTER CONTROLS CONTR CONTRACTOR W WASTE OR WIDTH OR WATTS �_�J� TAG NECK SIZE-CFM WALL SUPPLY GRILLE OR � MD MOTORIZED DAMPER COP COEFFICIENT OF PERFORMANCE W/ WITH O Q LL MECH MECHANICAL REGISTER(SEE {-- CP CONTROL PANEL OR CONDENSATE PUMP W10 WITHOUT SYMBOL DESCRIPTION SMOOTH RADIUS DUCT-ELBOW WITHOUT TURNING V � LL MERV MINIMUM EFFICIENCY RATING VALUE W OR CONDENSATE RETURN WE WET BULB TEMPERATURE CRG CEILING RETURN GRILLE MFR MANUFACTURER WC WATER COLUMN I�S VANES WALL RETURN OR E SCHEDULE) GRILLE w I— U) TEMPERATURE SENSOR �<'4- TAG NECK SIZE-CFM OR REGISTER{SEE SCHEDULE} W cIf CRR CEILING RETURN REGISTER MIN MINIMUM WEG WALL EXHAUST GRILLE I.-_MOCP MINIMUM OVER CURRENT PROTECTION W O , CSO CEILING SUPPLY DIFFUSER WG WATER GAUGE Q THERMOSTAT OR THERMOMETER 45 DEGREE BOOT LO-LOSS BRANCH FITTING LINEAR SLOT DIFFUSER(SEE IY LL MV MANUAL AIR VENT SCHEDULE FOR NUMBER OF V Y U) CTE CONNECT TO EXISTING {N) NEW WP WORKING PRESSURE CUFT CUBIC FEET WPD WATER PRESSURE DROP w ®o CARBON DIOXIDE SENSOR SLOTS).2-WAY THROW UNLESS LLI NIA NOT APPLICABLE 0 OLIN CUBIC INCHES WRR WALL RETURN REGISTER Y W NC NORMALLY CLOSED C?, WYE BRANCH FITTING NOTED OTHERWISE.EXAMPLES: _ L1_l � CV CONSTANT VOLUME OR CONTROL VALVE WSHP WATER-SOURCE HEAT PUMP o 5 OCCUPANCY SENSOR O z NIC NOT IN CONTRACT y SN10-48-250 REFERS TO TAG SN CW COLD WATER WSR WALL SUPPLY REGISTER o _ _ _ _ _ _ _ _ _ NO NORMALLY OPEN OR NUMBER w ACOUSTICAL LINING DUCT TAG NECK SIZE-LENGTH-CFM WITH 10' ROUND NECK, 48'SLOT D DROP OR DRAIN WT WEIGHT z HUMIDITY SENSOR OR HUMIDISTAT 12x6 w M NOM NOMINAL � © _ _ _ _ (DIMENSION IS INSIDE DIMENSION) LENGTH AND 250 CFM. CO DBT DRY BULB TEMPERATURE XFMR TRANSFORMER NTS NOT TO SCALE 0 © STATIC PRESSURE SENSOR Q DDC DIRECT DIGITAL CONTROL Z ZONE OA OUTSIDE AIR T { CAPPED OR PLUGGED TEE 11J DEFL DEFLECTION ZD ZONE DAMPER - OAD OUTSIDE AIR DAMPER a MOTORIZED DAMPER INSIDE DUCT DIA DIAMETER S REFRIGERANT SENSOR DIFF DIFFERENCE OAT OUTSIDE AIR TEMPERATURE ® M 1 � OBD OPPOSED BLADE DAMPER BLIND FLANGE,CAP CO DN DOWN OC ON CENTER 0 CARBON MONOXIDE SENSOR _ - ,�, CONCENTRIC REDUCER Z DP DIFFERENTIAL PRESSURE OD OUTSIDE DAMPER r TAG NECK SIZE-CFM TRANSFER DUCT(WITH LINER) DPD DEW POINT TEMPERATURE OFCI OWNER FURNISHED CONTRACTOR INSTALLED HQ HYDROGEN SENSOR _ _ it DSD DUCT SMOKE DETECTOR EXPANSION LOOP 5 DV DIAPHRAGM VALVE OFOI OWNER FURNISHED OWNER INSTALLED 5D DUCT SMOKE DETECTOR INDICATES 8'11" TO BOTTOM OF DUCT w VALVE ON RISE DWG(S) DRAWINGS(S) OPER OPERATING OFFICE COP O bX DIRECT EXPANSION OV OUTLET VELOCITY 4 IM OP TIGARD S TEMPERATURE SENSOR 8'-11' BOD 6' PIPE SIZE DIAMETER IN INCHES U (E) EXISTING P PUMP OR PRESSURE OR POLE I ) PC PUMPED CONDENSATE D FOR CODE COMPLIANCE EA EXHAUST AIR OR EACH PD PRESSURE DROP APPro�� ] ® STATIC PRESSURE SENSOR L -_ . - - EAD EXHAUST AIR DAMPER MISCELLANEOUS PIPING MECHA NDAND PF PREFILTER EAT ENTERING AIR TEMPERATURE OTCs [ ] ABBNREVIREM ATTIOIONS PG PIPE GUIDE OR PRESSURE GAUGEPermit� I _ -7 d- � � � PRESSURE SENSOR OR SWITCH Q� EC ELECTRICAL CONTRACTOR PH PHASE(ELECTRICAL) ���� SYMBOL DESCRIPTION SYMBOL DESCRIPTION EGON ECONOMIZER PHO PREHEA7C01L Address: ), oc�O Sw T? 1t' (J((� , d PS DIFFERENTIAL PRESSURE SENSOR PROJECT NO. EDB ENTERING DRY BULB TEMPERATURE Suite #: y o REFRIGERANT DISCHARGE DIRECTION OF SLOPE EAT ENTERING WATER TEMPERATURE POD PLUMBING FMS AIR FLOW MEASURING STATION 17055 POC POINT OF CONNECTION Byt Date: z EER ENERGY EFFICIENCY RATING U.LLy_ l REFRIGERANT SUCTION I• DIRECTION OF FLOW POD POINT OF DISCONNECTION o EF EXHAUST FAN 2 {S HUMIDITY SENSOR PRESS PRESSURE ` A EFF EFFICIENCY PIPE UP OR UP&DOWN WITH NOTATION) EJ EXPANSION JOINT PRV PRESSURE REDUCING VALVE � _ `�' PNEUMATIC CONTROL VALVE ( ) .20.20 PS PRESSURE SENSOR W 4 FLOW SENSOR OR SWITCH EL ELEVATION >_ AIR LINEPIPE DOWN ELEC ELECTRICAL PSI POUNDS PER SQUARE INCH PSIA PSI ABSOLUTE FM FLOW METER EQUIP EQUIPMENT z ® ST SOUNDTRAP a PIPE DROPIPIPE RISE 5 PSIG P51 GAUGE w o (ER)) EXISTING RELOCATED g QTY QUANTITY ©S CURRENT SENSOR 3 ESP EXTERNAL STATIC PRESSURE ® CC COOLING COIL TOP CONNECTION-BRANCH LINE E7 EXPANSION TANK R RELOCATE,RISE, RISER — � EWB ENTERING WET BULB TEMPERATURE RA RETURN AIR 0 MOTOR EXH EXHAUST RAD RETURN AIR DAMPER ® HC HEATING COIL BOTTOM CONNECTION-BRANCH LINE EXT EXTERNAL RD REFRIGERANT DISCHARGE OR ROOF DRAIN ❑A ACTUATOR n `� o F FAHRENHEIT REF ROOFTOP EXHAUST FAN ® RHT RADIANT HEATER �c PIPE ANCHOR FC FLEXIBLE CONNECTION OR FAIL CLOSED REFRIG REFRIGERATION 8 FCU FAN COIL UNIT REJ REJECTION VALIDITY OF PERMIT Al ANALOG INPUT AO ANALOG OUTPUT ® BHT BASEBOARD HEATER TEE UP FD FIRE DAMPER REQ'D REQUIRED FF FINAL FILTER OR FINISHED FLOOR REV REVISE, REVISION OR REVOLUTIONS THE ISSUANCE OF A PERMIT DI DIGITAL INPUT ® CB CHILLED BEAM s TEE DOWN RF RETURN FAN BASED ON CONSTRUCTION DO DIGITAL OUTPUT T FFAIFFB FROM FLOOR ABOVEIBELOW DOCUMENTS AND OTHER BAS BUILDING AUTOMATION SYSTEM THRUST BLOCK TEST TAP(PETE'S PLUG) FLR FLOOR DATA SHALL NOT PREVENT PI PULSING INPUT z THE CODE OFFICIAL FROM FLEXIBLE CONNECTOR REQUIRING THE CORRECTION UNION �o MQ OF ERRORS. OSSC 105.4.48a b ARD Approved by Planning Date: kk- � Initials: _ L el�5013ti7%3 DIGITAL SIGNATURE MECHANICAL BASIS OF DESIGN K. ACOUSTICAL rFp OREGON��q A. THIS BUILDING IS A FOUR-STORY MULTIFAMILY RESIDENTIAL DEVELOPMENT OF 48 UNITS TOTAL, THE GROUND 1. THE FOLLOWING NOISE NCIRC CRITERIA LEVELS WILL BE ACHIEVEDAND AS DEFINED IN THE FLOOR INCLUDES A LOBBY, LOUNGE, LEASING OFFICES,COMMUNITY ROOM AND BICYCLE STORAGE. EACH ASHRAE HVAC APPLICATIONS HANDBOOK. THESE LEVELS ADDRESS THE MECHANICAL SYSTEMS RESIDENTIAL FLOOR INCLUDES A COMMUNITY LAUNDRY ROOM AND BIKE ROOM. ONLY. ACTUAL SOUND PERFORMANCE REQUIREMENTS FOR EACH SPACE MUST BE VERIFIED WITH RENEWS: 06-30-2020 B. THE DESIGN INCLUDES THE FOLLOWING NOTABLE FEATURES, BUT IS NOT LIMITED TO THIS SCOPE. CONTRACTOR IS ACOUSTICAL CONSULTANT. RESPONSIBLE FOR REVIEWING ALL CONTRACT DOCUMENTS AND COORDINATING WITH ALL DISCIPLINES. A. CORRIDORS AND LOBBIES: 30 TO 40 1. VENTILATION AND EXHAUST: B. LIVING AREAS:25 TO30 )jtlb FRfD ESHN A. A CONSTANT VOLUME PACKAGED ROOFTOP.MAKEUP AIR UNIT PROVIDES VENTILATION TO THE M. SEISMIC; O'WIWOMAEMN 6 FN CORRIDORS. VARIABLE VOLUME CEILING EXHAUST FANS PROVIDE EXHAUST TO APARTMENT 1. ANCHORAGE AND RESTRAINTS MUST BE COORDINATED WITH STRUCTURAL ENGINEER AND AUTHORITY CNiE NO6iN£S.tF.IEE FRED E.SHAU&ME OE:j F'F'2# ,4DLNWk4E,P TOILETS. VARIABLE VOLUME DUCTED RANGE HOODS PROVIDE EXHAUST TO APARTMENT KITCHENS. HAVING JURISDICTION, FSM,IYn.N wN,anb ax EXHAUST RUNS ROUTE TO BOTH ROOF LOUVERED PENTHOUSES AND EXTERIOR LOUVERS DEPENDING ON N. THE HVAC SYSTEM INCLUDES THE FOLLOWING SUSTAINABLE DESIGN FEATURES: „fi°,, LOCATION. 1. SELECT REFRIGERANTS AND HVAC EQUIPMENT THAT MINIMIZE AND ELIMINATE THE EMISSION OF B. UNITS ARE VENTILATED THROUGH THE PTAC PORT AND LOW AIRFLOW SETPOINT AT BATHROOM FANS COMPOUNDS THAT CONTRIBUTE TO OZONE DEPLETION. C. BEDROOMS ARE NATURALLY VENTILATED THROUGH OPERABLE WINDOWS, ARCHITECT TO PROVIDE MIN. 2. HEAT PUMP HEATING SOLUTION IN LIVING ROOMS WHICH IS-3 TIMES MORE EFFICIENT THAN ELECTRIC 4%OF THE BEDROOM FLOOR AREA AS WINDOW OPEN-ABLE AREA TO COMPLY WITH VENTILATION CODE,DOOR RESISTANCE UNDERCUTS ARE PROVIDED BETWEEN BEDROOM & LIVING ROOM PER EARTH ADVANTAGE REQUIREMENTS. 3. PROVIDE INDOOR AIR QUANTITIES TO MEET MINIMUM REQUIREMENTS OF SECTIONS 4 THROUGH 7 OF 2. HEATINGICOOLING: ASHRAE STANDARD 62.1-2010. A. COMMUNITY ROOM:SPLIT HEAT PUMP AND CEILING FAN. 4. USE VARIABLE FREQUENCY DRIVES OR EC MOTORS TO OPERATE FANS. N B. RESIDENTIAL UNITS:PTHP WITH OUTSIDE AIRPORT IN LIVING ROOM, SIZED TO COOL ALL AREAS OF THE APARTMENT. elm BEDROOM HEATING VIA COVE WALL HEATER. 3. CONTROLS; DUE TO THE SIMPLICITY OF THE PROJECT NO BUILDING AUTOMATION SYSTEM(BAS) HAS BEEN SPECIFIED, EACH SYSTEM WILL OPERATE ON ITS OWN CONTROLS. C. CODES AND STANDARDS 1, AMERICANS WITH DISABILITIES ACT(ADA) Z NFPA 90A:STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2012 EDITION. 3. NFPA 908:STANDARD FOR THE INSTALLATION OF WARM AIR HEATING AND AIR-CONDITIONING enc SYSTEMS, 2012 EDITION. 4. NFPA 99:HEALTH CARE FACILITIES CODE, 2012 EDITION. 5. NFPA 101: LIFE SAFETY CODE, 2012 EDITION, 6. OREGON BUILDING CODES ENFORCED BY THE AUTHORITY HAVING JURISDICTION (AHJ): A. 2014 OREGON STRUCTURAL SPECIALTY CODE(OSSC)BASED ON THE 2012 INTERNATIONAL BUILDING CODE(IBC). B. 2014 OREGON MECHANICAL SPECIALTY CODE(GMSC) BASED ON THE 2012 INTERNATIONAL MECHANICAL CODE(IMC)AND THE 2012 INTERNATIONAL FUEL GAS CODE (IFGC)WITH STATE AMENDMENTS. C. 2014 OREGON PLUMBING SPECIALTY CODE(OPSC)BASED ON THE 2009 UNIFORM PLUMBING CODE (UPC). D. 2014 NATIONAL ELECTRICAL CODE(NEC)WITH STATE AMENDMENTS. E. 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE(DEESC) BASED ON THE 2014 z INTERNATIONAL ENERGY CONSERVATION CODE (IECC), F. ADDITIONAL STATE AND LOCAL JURISDICTION REQUIREMENTS. W D. OUTDOOR DESIGN CONDITIONS: D 1. LOCATION: PORTLAND, OR co O 2. SUMMER: 91,4°FDB167,3°FW8(ASHRAE 0.4%) N = 3. WINTER:25.27(ASHRAE 0.2%OR MEDIAN OF EXTREMES) Ll I 4. ELEVATION: 108 FT. 5. CLIMATE ZONE:4C(2014 OEESC,CHAPTER 3) � m M E. INDOOR DESIGN CONDITIONS Z �' 1. ALL CONDITIONED AREAS: O O A, COOLING:75°F+f-2"F 0 B. HEATING: 70°F+l-2°F 2. EXCEPTIONS: 0 < A. ELEC.ROOMS: 90°F+1.2°F MAXIMUM 0 LL B. DATAlTELECOM ROOMS:COOLING ONLY,76°F+1-2"F(MAXIMUM) Q W C. ELEVATOR CONTROL ROOMS:COOLING ONLY. 76°F+l-2°F(MAXIMUM) Y ~ 3. HUMIDITY CONTROL W qg �. A. ALL AREAS, UNLESS OTHERWISE NOTED: NONE W 0 F, OREGON VENTILATION CRITERIA: CC LL_ 1. COMPLY WITH CHAPTER 4 OF OMSCIIMC AND ASHRAE 62.1. (.} ry G. EXHAUST TO OUTDOORS(MINIMUM RATES) a LL1 1. APARTMENT TOILET ROOMS:80 CFM(OSMC INTERMITTENT STRATEGY) U = W a 2. KITCHENS: 150 CFM(OMSC INTERMITTENT STRATEGY) 0 (- z 4. JANITOR CLOSET: 1CFWSQ. FT, CFM OR 10 AIR CHANGES PER HOUR,WHICHEVER IS GREATER. 00 �-- 5. BIKE STORAGE: 0.25 CFMI SQ. FT. CQ 6. MAIN TRASH ROOM: 12-15 AIR CHANGES PER HOUR Q 7, DRYERS: DIRECT VENTED TO EXTERIOR, BOOSTER FANS AS NECESSARY. W r H. BUILDING ENVELOPE i. GLAZING:GLASSIFRAME COMBINATION A. ALL LEVELS: C) 1) DESCRIPTION: PUNCHED WINDOW, DOUBLE PANE Q Z 2) U=0.29 c- 3) SOLAR HEAT GAIN FACTOR(SHADING COEFFICIENT) =0.30 2. WALL CONSTRUCTION: A. WOOD FRAMING AT 1600C B. INSULATION: 5.5" FIBERGLASS BATT +2'ci C) U C. OVERALL U-VALUE=R-23+R-Gd 3, ROOF CONSTRUCTION, A. 24"olc WOOD FRAMING BASIS OF DESIGN AND B. INSULATION: 30ci(2layres of 2..6"closed cell rigid TABULATED DATA C. OVERALL UNALUE=R-23+13-6ci I. DUCTWORK DESIGN CRITERIA (MAXIMUM ALLOWABLE AIR PRESSURE DROPS AND AIR VELOCITIES)TO MEET HIGH EFFICIENCY OPERATION WITH MINIMAL ACOUSTICAL NOISE. DUCT STATIC PRESSURE FRICTION LOSS SHALL NOT PROJECT NO, EXCEED 0.2' PER 100 FEET IN MECHANICAL ROOMS AND SHAFTS. LOW PRESSURE SUPPLY DUCT STATIC 17055 PRESSURE FRICTION LOSS BASED ON A MAXIMUM OF 0.08' PER 100 FEET. LOW PRESSURE RETURN AND EXHAUST DUCT STATIC PRESSURE FRICTION LOSS BASED ON A MAXIMUM OF 0.06" PER 100 FEET. MEDIUM PRESSURE DUCTWORK SHALL NOT EXCEED A DUCT STATIC PRESSURE FRICTION LOSS BASED ON A MAXIMUM OF 06.20.2019 0.1"PER 100 FEET. 1. MAXIMUM SUPPLY, RETURN AND EXHAUST DUCT AIR FLOW VELOCITIES SHALL NOT EXCEED THE FOLLOWING CRITERIA: A, MAINS ABOVE CEILING:MAXIMUM 1750 FPM VELOCITY B. MAINS ABOVE OPEN OCCUPIED SPACES: MAXIMUM 1450 FPM VELOCITY o C. BRANCHES ABOVE CEILING: MAXIMUM 1400 FPM VELOCITY D. BRANCHES ABOVE OPEN OCCUPIED SPACES: MAXIMUM 1150 FPM VELOCITY E, RUN-OUTS TO DIFFUSERS: MAXIMUM 725 FPM VELOCITY Q 0 F. IN SHAFTS:MAXIMUM 2500 FPM VELOCITY a w G. IN MECHANICAL ROOMS: MAXIMUM 3000 FPM VELOCITY a 2. KITCHEN EXHAUST DUCT SHALL RANGE FROM 500 FPM IN VAV SYSTEMS(MINIMUM) TO MAXIMUM S 2500 FPM VELOCITY, w J. DIVERSITY ASSUMPTIONS 1. FANS: PROVIDE FOR DUCT LEAKAGE AND 10%ADDITIONAL AIR CAPACITY FOR FUTURE EXPANSION U Eff a z O E momol Ow 010373% APARTMENT VENTILATION MAKE -UP AIR UNIT - GAS HEATING, DX COOLING DIGITAL SIGNITURE SUPPLY ELECTRICAL COOLING (AT 95'F AMBIENT) HEATING FILTER s OREGOfJ �q NOMINAL EMERG EAT LAT NET 21 �� MANUFACTURER CAPACITY AIRFLOW ESP VFD AICA MOCP PpWER TOTAL SENS DBIWB DBIWB REFRIG REFRIG INPUT OUTPUT EAT DB LAT DB UNITSIZE OPER. WT. TAG MODEL NUMBER ONS (CFM) ON WG) DRIVE HP YIN VOLTS PH (A) ((A) YIN (MBH) (MBH) eF) ('F) EER TYPE (LBS) (MBH) (MBH) (F) PF) TYPE MERV L"x1MxH" LBS S M U A R-1 TRA E PRECEDENT HIGH-EFF. 6 T 2,700 1.0 DIRECT 1 2.75 Yes 208 3 37 50 1 Na 75 75.0 9W67 57156 13.1 R410A 5.814.1 150 121.5 20 80 CART 13 9"x54"x47' 918 RENEWS; 06-30-2020 NOTES 1. COORDINATE WITH ELECTRICAL FOR POWER AND DISCONNECTAS REQUIRED- SINGLE POINTOF POWER. 2, PROVIDE INVERTER READY NEMA PREMIUM EFFICIENCY MOTOR WITH SHAFTGROUNOING SYSTEM. � ypy� eebyFedE. 3. PROVIDE VFD WITH UNIT FOR SOFT START. t�°a ne.com. 4. PROVIDE FACTORY STANDARD 14"HIGH ROOF CURB. Fre au T{J=Fled E.Sha"b 5. UNIT TO HAVE HORIZONTAL DISCHARGE FOR SUPPLY #g- ;4::tilieon - eppr°Nng thlz d"cumepC=: 0 6. PROVIDE NATURAL GAS HEATING AT 11" WG MIN. • 7. FACTORY PROVIDE CONViENECE OUTLET MOUNTED ON SIDE OF UNIT 8. PROVIDE FURNACE MODULATING CONTROL, 9. PROVIDE FACTORY CONTROLS -CONTROLLED ZONE TEMPERATURE. 10. PROVIDE CONDENSER COIL GUARD. 11, PROVIDE LOW AMBIENT CONTROL FOR OPERATION DOWN TO 20"F. 12, PROVIDE WITH (2) SINGLE SPEED SCROLL COMPRESSORS. .2:a .. lip TYPICAL RESIDENTIAL RESTROOM EXHAUST FAN SCHEDULE TYPICAL DRYER BOOSTER_ FAN SCHEDULE `N' ELECTRICAL OPER. ELECTRICAL AIRFLOW MAX AIRFLOW MIN SP UNIT SIZE WT. AIR EMERG OPER. TAG # MANUFACTURER MODEL NUMBER LOCATION AREA SERVED TYPE DRIVE (CFM) (CFM) (IN WG) SONES WATTS VOLTS PH (L"xW"xH") (LBS) NOTES FMANUFACTURE FLOW SP FAN MTR VFD POWER UNIT SIZE WT. -c TEF 1 PANASONIC FV-05-11VK1 SEE PLANS UNIT BATHROOMS CEILING FAN DIRECT 80 40 CFM 0.25 0.3 5.5 120 1 17"x15'x12" 12 1-7 TAG # MODEL NUMBER LOCATION AREA SERVED DISCH (CFM) (IN WG) RPM RPM WATTS VOLTS PH (YIN) (YIN) (L"xW"xH") (LBS) NOTES DBF 1 REVERSOMATIC TLO-200ES(1 SEE PLANS LAUNDRY INLINE 220 0.2 2500 2500 78 120 1 No No 11'x11"x8" 50 1-3 NOTES INLET) 1. STARTER BY MECHANICAL. 2. MOUNTED PER MANUFACTURER REQUIREMENTS. COORDINATE EXACT FRAMING REQUIREMENTS WITH GC. NOTES 3. PROVIDE INTEGRAL FACTORY PROVIDED BACKDRAFT DAMPER 1. COORDINATE WITH ELECTRICAL FOR POWER AND DISCONNECT AS REQUIRED. 4. FAN RUNS CONTINUOUS AT LOW AIRFLOW SETPOINT AT ALL TIMES AND RAMPS UP TO HIGHER AIRFLOW VIA LOCAL ONIOFF WALL SWITCH. SEE ELECTRICAL. 2, PROVIDE WITH CURRENT SENSOR AND RELAY.INTERLOCK FAN OPERATION WITH DRYER OPERATION, 5. FAN SHALL BE ENERGY STAR CERTIFIED 3, INSTALL PER MANUFACTURER REQUIREMENTS. 7. MINIMUM AIRFLOW SETPOINT SHALL TRACK WITH VENTILATION AIRFLOW RATE SUPPLIED TO INDIVIDUAL APARTMENTS. TAB TO VERIFY AND ADJUST AS NECESSARY TO MAINTAIN ROOM AIR FLOW RATE. FAN SCHEDULE z ELECTRICAL U) AIR MIN. EMERG OPER. FLOW SP EFF. FAN MTR VFD POWER UNIT SIZE WT. coN ° ) ( "xW"0"} (LBS) NOTES W TAG # MANUFACTURER MODEL NUMBER LOCATION DISCH TYPE DRIVE (CFM) (IN WG) (/°} RPM RPM WATTS BHP HP VOLTS PH (YIN) (YIN) L xW' EF 1-1 PANASONIC FV_11_15VK1 TRASH 125 HORIZONTAL CEILING INSERT DIRECT 115 0.25 6.6 120 1 No No 17" "xi2' 15 9-13 J .EF 1.2 PANASONIC FV_1i_15VKI LAUNDRY 123 HORIZONTAL CEILING INSERT DIRECT 115 0.25 6.6 120 1 No No 17"x15"x12" 15 9-13 Z [� m EF 1.3 PANASONIC FV-05-11VK1 JANITOR 122 HORIZONTAL CEILING INSERT DIRECT 50 0.25 3,4 120 1 No No 17"x15"x12" 15 9-13 0 Q - -- -- EF 1-4 GREENHECK SQ-70-VG B KE 137 HORIZONTAL INLINE DIRECT 185 0.4 20 1651 1725 0.04 0.1 120 1 No No 16"x12"x12" 35 1.7 Q 0 EF 1-5 PANASONIC FV-05-11VKI BIKE 121 HORIZONTAL CEILING INSERT DIRECT 50 C,25 3.4 120 1 No No 17"x15"x12" 15 9-13 cl� EF 2-2 PANASONIC FV_11_15VK1 LAUNDRY223 HORIZONTAL CEILING INSERT DIRECT 115 0.25 6.6 120 1 No No 17"x15"x12" 15 9-13 - 0 < O W EF 2-3 PANASONIC FV-05-11VK1 JANITOR 222 HORIZONTAL CEILING INSERT DIRECT 50 0.25 3.4 120 1 No No 17"x15'x12' 15 9-13 Y )-- Q U) EF 2-4 PANASONIC FV-05-IIVK1 BIKE 221 HORIZONTAL CEILING INSERT DIRECT 50 0.25 3.4 120 1 No No 1705'x12' 15 9-13 ll.) ry EF 3-2 PANASONIC FV_11 15VK1 LAUNDRY 323 HORIZONTAL CEILING INSERT DIRECT 115 0.25 6.6 120 1 No No 17'xi5'x12' 15 9.13 O EF 3-3 PANASONIC FV-05-11VK1 JANITOR 322 HORIZONTAL CEILING INSERT DIRECT 50 0.25 3.4 120 1 No No 17'x15"x12" 15 9-13 V U) EF 3-4 PANASONIC FV-05-11VK1 BIKE 321 HORIZONTAL CEILING INSERT DIRECT 50 0.25 3.4 120 1 No No 17'xl5*xl2" 15 9-13 Y o- of W U = LL1 4. EF 4-2 PANASONIC FV_III_15VK1 LAUNDRY 423 HORIZONTAL CEILING INSERT DIRECT 115 0.25 6.6 120 1 No No 17"x15'x'.2' 15 9-13 0 F ' )Zco -' EF 4-3 PANASONIC FV-05-11VK1 JANITOR 422 HORIZONTAL CEILING INSERT DIRECT 50 0.25 3.4 120 1 No No 17"x15'x12" 15 9-13 _ (0 EF 4A PANASONIC FV-05-11VK1 BIKE 421 HORIZONTAL CEILING INSERT DIRECT 50 0.25 34 120 1 No No 1Tx15'x12' 15 9-13 - EF B-1 GREENHECK SQ-80-VG ELF 002 HORIZONTAL INLINE DIRECT 280 0.4 30 1582 1725 0.06 0.1 120 1 No Yes 19'x15"x15" 50 i-8 _ W U EF B-2 GREENHECK SQ-70-VG LOWVOLTAGE003 HORIZONTAL INLINE DIRECT 100 0.4 20 1651 1725 0,03 0.1 120 1 No Yes 16'x12"x12" 35 1-8 O SF 1-5 GREENHECK SQ-80-VG ICOMM. ROOM CLOSET HORIZONTAL INLINE DIRECT 275 0.4 30 1582 1725 0.06 0.1 120 1 No No 19"x15"x15" 50 1-7 m az NOTES r � 1. COORDINATE WITH ELECTRICAL FOR POWER AND DISCONNECT AS REQUIRED, 2. PROVIDE NEMA PREMIUM EFFICIENCY MOTOR. 3. PROVIDE NON-OVERLOADING MOTOR, O 4. PROVIDE ECM(ELECTRONICALLY COMMUTATED MOTOR)WITH FACTORY MOUNTED POTENTIOMETER FOR SPEED ADJUSTMENT. U 5, PROVIDE VIBRATION ISOLATION AND SEISMIC RESTRAINT PER SPECIFICATIONS. 6. PROVIDE MOTORIZED DAMPER(WITH END SWITCH). 7. PROVIDE BIRDSCREEN. SCHEDULES 8. PROVIDE(LINE-VOLTAGE 124V)THERMOSTAT). 9, STARTER BY MECHANICAL. 10. MOUNTED PER MANUFACTURER REQUIREMENTS. COORDINATE EXACT FRAMING REQUIREMENTS WITH GC. PROJECT NO. 11. PROVIDE INTEGRAL FACTORY PROVIDED BACKDRAFT DAMPER 17055 12. FAN RUNS CONTINUOUS AT LOW AIRFLOW SETPOINT AT ALL TIMES AND RAMPS UP TO HIGHER AIRFLOW UPON OCCUPANT ADJUSTABLE LOW VOLTAGE TIME DIAL. SEE ELECTRICAL FOR DIAL LOCATION. 13. FAN SHALL BE ENERGY STAR CERTIFIED --- ---- --- - --- 06.20.2019 5 0 w v 0 0 rc a w rc O z 8 w K 2 V x a Y O a_ M0002 8w 8a TYPICAL PACKAGED TERMINAL HEAT PUMP SCHEDULE ^03N7e3 COOLING HEATING ELECTRICAL EMERG OPER. TOTAL CAP MCA MOCP HEAT POWER UNIT SIZE WT. DIGITAL SIGNATURE TAG # MANUFACTURER MODEL NUMBER LOCATION REFRIG EER COP MBH TU VOLTS PH (A) (A (KIN) L"x W"x H") (LBS) NOTES PTHP A AMANA PTH073G-50AQVX SEE PLANS R-410A 12 3.3 7600 4200 208 1 8.5 15 1.3 No 42x22x17 110 15 PTHP B AMANA PTH093G-50AQVX SEE PLANS R-41 DA 12 3.3 9000 4200 208 1 8,5 15 1.3 No 42x22x17 115 1-5 PTHP C AMANA PTH123G-15AQVX SEE PLANS R41 OA 11 3.2 12000 4200 1 208 1 8.5 15 1.3 No 42x22x17 120 1-5 PTHP D AMANA PTH153G-25AQVX SEE PLANS R410A 9.7 0 1 14700 6800 208 1 14.1 15 F 2.1 No 42x22x17 1 130 1-5 RENEWS: 06-30-2020 by Lam NOTES ' F'� CL 4.Ii;C!1NLlN,Meaf"a tmn. "DVNIQN Kit1■ R,3-. 5. a FLD E.91NW,1A I. COORDINATE WITH ELECTRICAL FOR POWER AND DISCONNECT AS REQUIRED. FWD ,r eswr�k+e•�`'::oa'` ` '.s$I ieum{f�frMvalarm 2. UNIT CAPACITY RATED AT ARI STANDARD CONDITIONS. 3. PROVIDE PROGRAMMABLE THERMOSTAT WITH TEMPERATURE SETPOINTS FOR AT LEAST FOUR SCHEDULING PERIODS WITHIN 24 HOURS, 1 `3< ih uaora 4, PROVIDE METAL INSULATED WALL SLEEVE. 5. PROVIDE ALUMINUM ARCHITECTURAL OUTDOOR GRILLE. TYPICAL ELECTRIC COVE HEATER SCHEDULE ELECTRIC UNIT HEATER SCHEDULE ELECTRICAL EMERG ELECTRICAL EMERG OPER. Cm E E K MODEL NEAT CAP MCA POWER UNIT SIZE OPER.WT. AIR FLOW HEAT CAP POWER UNIT SIZE WT. TAG # MANUFACTURER NUMBER LOCATION TYPE (W) VOLTS pH (A) (Y)N) (L"xW"xH") (LBS) NOTES TAG # MANUFACTURER MODEL NUMBER LOCATION TYPE (CFM) (KW) VOLTS PH KW IN (L"xW"xH") (LBS) NOTES ` CH 1 QMARK RCC-750 ABOVE WINDOW COVE 750 208 1 3.5 No 60'X475" 10 1-3 UH 1-1 QMARK/MARLEY CU935 STAIR 01 CABINET 250 2 208 1 2.00 No 35"AWx27' 120 13 UH 1-2 QMARK I MARLEY MUH0381 ELEC 002 CEILING HUNG 350 3 208 1 3.00 No 1410'x16" 30 1-3 uc NOTES UH 13 CADET APEX72-HWO78 LOUNGE 136 WALL MOUNT 100 0.75 208 1 0.75 No 12"x4'x8.5' 10 13 I. DISCONNECT PROVIDED BY ELECTRICAL. UH 2-1 CADET APEX72-HWO78 STORAGE 225 WALL MOUNT 100 0.75 208 1 1 0.75 1 No 129A)0.5' 10 13 2. MOUNT PER MANUFACTURERS REQUIREMENTS AND MAINTAIN REQUIRED CLEARANCES, UH 34 CADET APEX72-HWO78 STORAGE 325 WALL MOUNT 100 0.75 208 1 0.75 No ITANx8.5' 10 13 3. PROVIDE WALL MOUNTED LINE VOLTAGE THERMOSTAT.SEE ENLARGED PLANS FOR LOCATION IN ROOM. ELECTRICIAN SHALL RUN WIRING, UH 4-1 CADET APEX72-HWO78 STORAGE 425 WALL MOUNT 100 0.75 208 1 0.75 No 12'x4'x8.5' 10 1.3 UH B-1 QMARK I MARLEY MUH0381 ELEC 002 CEILING HUNG 350 3 208 1 3.00 No 14'x8'x16 30 13 UH B-2 QMARK 1 MARLEY MUH0381 LOW VOLTAGE 003 CEILING HUNG 350 3 208 1 3.00 No 14'x84x16' 30 13 UH B-3 QMARK 1 MARLEY CU935 STAIR 02 CABINET 250 2 208 1 2.00 No 35'x10°x27' 120 1-3 NOTES 1. DISCONNECT PROVIDED BY ELECTRICAL. 2. MOUNT PER MANUFACTURER'S REQUIREMENTS AND MAINTAIN REQUIRED CLEARANCES. Z 3. PROVIDE 24V CONTROL TRANSFORMER AND FACTORY PROVIDED TAMPER PROOF REMOTE WALL MOUNTED THERMOSTAT. DIV 23 TO RUN CONTROL WIRING. (!1 N SPLIT SYSTEM HEAT PUMP CONDENSING UNIT SCHEDULE _ N ti COOLING (95°F ODBI80°F IDB/67°F HEATING (47°F (n --1 EWB) ODBI70°FIDB) ELECTRICAL Z O� m EMERG 00 FAN COIL NOM.CAP. NOM.CAP. REFRIG MOCP POWER UNIT SIZE OPER.WT. TAG # TAG MANUFACTURER MODEL NUMBER LOCATION (MBH) EER SEER (MBH) HSPF TYPE VOLTS PH MCA(A) (A) (Y)N) L"xW"xH" (LBS) NOTES cl� CU R-1 1-1 DAIKIN RZQ42PVJU9 ROOF 42 11 16 47 9 R410A 208 1 3.6 15 Yes 52"x36"x13" 285 13 '� � 0 CU R-2 1-2 DAIKIN RZQ24PVJU9 ROOF 24 12 16.5 27 10.5 R410A 208 1 16.5 20 Yes 30"x35"x13" 150 13 V LL W NOTES: W ~ W 1. COORDINATE WITH ELECTRICAL FOR POWER AND DISCONNECTS AS REQUIRED. F- W 2.REFRIGERANT PIPE SIZES PER MANUFACTURER'S REQUIREMENTS. 0� LL- 2 3,ALL REFRIGERANT PIPING&ELECTRICAL CONNECTIONS MUST BE FROM BOTTOM OF UNIT TO ALLOW UNITS TO BE MOUNTED DIRECTLY NEXT TO EACH OTHER. Y d U) W SPLIT SYSTEM HEAT PUMP FAN COIL SCHEDULE 0 �-- Z 00 COOLING CAPACITY SUPPLY ELECTRICAL TOTAL EMERG OPER. w U COND UNIT MODEL TOTAL SENSIBLE HEATING AIR FLOW MCA POWER UNIT SIZE WT. TAG # TAG MANUFACTURER NUMBER LOCATION (MBH MBH (MBH) (CFM) VOLTS PH (A) (YIN) (W"xHxD'7 (LBS) NOTES FCU 1-1 R-1 DAIKIN FTQ42PBVJU COMMUNITY ROOM 40 27.9 47 1400 208 1 1,6 No 58'x22x26' 205 15 FCU 1-2 R-2 DAIKIN FBQ24PVJU OFFICE 131 24 18.7 27 690 208 1 1.8 No 4("x28°x12" 80 15 z r Z) NOTES Q 1, COORDINATE WITH ELECTRICAL FOR POWER AND DISCONNECT AS REQUIRED. (� 2. PROVIDE LOW VOLTAGE WI RED PROGRAMMABLE THERMOSTAT WITH TEMPERATURE SETPOINTS FOR AT LEAST FOUR SCHEDULING PERIODS WITHIN 24 HOURS.' 3. SYSTEM SHALL BE CABPLE OF REFRIGERANT PIPE RUNS UP TO 164 FT. 4. PROVIDE WITH INTERNAL MOISTURE SENSOR INTERLOCKED WITH UNIT SHUTDOWN FOR SECONDARY CONDENSATE PROTECTION. SCHEDULES 5. PROVIDE WITH INTERNAL CONDENSATE PUMP PROJECT NO. DIFFUSER AND GRILLE SCHEDULE 17055 TAG MANUFACTURER MODEL DESCRIPTION FACE TYPE FACE SIZE COLOR MATERIAL OBD NOTES EA TITUS 23RL AEROBLADE EXHAUST GRILLE 3/4'SPACING,45"DEFL. SEE PLANS WHITE STEEL NO 2,3,4,5,6,7 06.20.2019 RA TITUS 23RL AEROBLADE RETURN GRILLE 3/4'SPACING,45"DEFL. SEE PLANS WHITE STEEL NO 2,3,4,5,6,7 RB TITUS PAR SQUARE CEILING RETURN PERFORATED 24x24 STEEL STEEL NO 1,2,3,4 SA TITUS 272RS AEROBLADE SUPPLY GRILLE 314'SPACING, DOUBLE DEFL. SEE PLANS WHITE STEEL NO 2,3,4,5,6 5 SB TITUS MCD SQUARE CEILING SUPPLY MODULAR CORE 2424 WHITE STEEL NO 2,3,4,5,6,7 NOTES: 1. SUBMIT DIFFUSER PACKAGE TO ARCH ITEC TO REVIEW COLOR OPTIONS IN CA, 2. MAXIMUM TOTAL PRESSURE DROP SHALL NOT EXCEED 0.15"WG WITH DUCT TRANSITION. IS 3. MAXIMUM NC LEVEL SHALL BE 25. 4. ALL VISIBLE SURFACES AND DUCTWORK BEHIND FACE SHALL BE PAINTED FLAT BLACK. 5. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLANS FOR BORDER TYPES. 6, NECK SIZE AND CFM SHOWN ARE ON PLANS(EXAMPLE:SA12x12-400 REFERS TO TAG*SX WITH 12x12 NECK AND 400 CFM). 7. PROVIDE RECTANGULAR/SQUARE TO ROUND TRANSITION AS REQUIRED AND SIZED FOR MAXIMUM 0.01"WG TOTAL PRESSURE DROP. 4 8. PLENUM CONNECTION SIZE,SLOT LENGTH,AND CFM SHOWN ON PLANS(EXAMPLE:SL8-120-2000 REFERS TO TAG'SL'WITH 8'ROUND CONNECTION, 120'CONTINUOUS SLOT LENGTH AND 2000 CFM). 9. PROVIDE MANUFACTURER'S INSULATED PLENUM. o � MO , 03 ow Un 01�0%373 DIGITAL SIGNATURE ,J. OREGON q GMSC CHAPTER 4 VENERATION SCHEDULE Area or Exhaust Area Occupant Breathing zone Zone Air RENEWS: 06-30-2020 Area Outdoor Air Rate Outdoor Maximum Expected Outdoor Air per Outdoor Air Outdoor Air Distribution Zone Outdoor SYSTEM Room USE (Az) (Ra) Air (RaAz) OccupantDensity Occu anc Pz average Occupant (Rp) (RpPz) (Vbz) Effectiveness (Ez) Air(Voz) # AsiaCFM S _ CFM Occ/10005 OCC OCC CFM/OCC CFM CEM CR4 &, x M"'MEE" [1 1 [2] [3] [1] [4] [5] _[6) Y nd.o uvlacnuE u R AWIbAOS WCES.I MLtA 13Z CONFERENC MEETING 700 0.06 42 50 35 35 5 175 217 0.8 271 �L=eesEt q rneoEaH FRED E,eH4" 1M6.8E_'. �+U art�n MUA 129 RECEPTION AREAS 200 0.06 12 30 6 6 5 30 42 0.8 53 •- ° � , �'oeowNU s MUA 130 OFFICE SPACE 115 0.06 7 5 1 1 5 5 12 0.8 15 =' 'cwaaa .n 1A10°' MUA 131 OFFICE SPACE 120 0.06 7 5 1 1 5 1 5 12 0.8 15 k aramrssg+ammo MLA 136 RECEPTION AREAS 215 0.06 13 30 7 7 5 35 48 0.8 W MUA 127/128J129 CORRIDORS 950 0.06 57 0 0 0 0 0 57 0.8 71 100 a/o outside air system TOTAL (Vot) 485 GROUND FLOOR _ MLA 101 APARTMENT 480 0.06 29 4 2 2 5 10 39 1 39 . n ML)A 102 APARTMENT 480 0.06 29 4 2 2 5 10 39 1 39 LUMP-It..imam MUA 103 APARTMENT 480 0.06 29 4 2 2 5 10 39 1 39 MM 104 APARTMENT 530 0.06 32 4 3 2 5 15 47 1 47 w�U MUA 106 APARTMENT 465 0.06 28 4 2 2 5 10 38 1 38 MUA 107 APARTMENT 465 0.06 28 4 2 2 5 10 38 1 38 MLA 108 APARTMENT 480 0.06 29 4 2 2 5 10 39 1 39 uc MLA 109 APARTMENT 480 0.06 29 4 2 2 5 10 39 1 39 MLA 110 APARTMENT 480 0.06 24 4 2 2 5 10 39 1 39 MUA CORRIDORS 950 0.06 57 0 0 0 D 071 57 0.8 7i 100 o/a outside air system TOTAL (Vot) 427 FLOORS 2A4 4 MUA 1 APARTMENT 480 0.06 29 4 2 2 5 10 39 1 39 MLA 2 APARTMENT 480 0.06 29 4 2 2 5 10 39 _ 1 39 MLA 3 APARTMENT 480 0.06 29 4 2 2 5 10 39 1 39 MUA 4 APARTMENT 530 0.06 32 4 3 2 5 15 47 1 47 Z MLA 5 APARTMENT 460 0.06 29 4 2 2 5 10 39 1 34 MLA 6 APARTMENT 465 0.06 28 4 2 2 5 10 38 1 38 MUA 7 APARTMENT 465 0.06 28 4 2 2 5 10 39 1 38 M O MUA 8 APARTMENT 480 0.06 29 4 2 2 5 10 39 1 39 N = MUA 9 APARTMENT 4B0 0.06 29 4 2 2 5 10 39 1 39 MLA 10 APARTMENT 480 0.06 29 4 2 2 5 10 39 1 39 L1.] MLA 11 APARTMENT 475 0.06 2.9 4 2 2 5 10 39 1 39 00 m MUA 12 APARTMENT 480 0.06 29 4 2 2 5 10 39 1 39 Z 0 MUA 13 APARTMENT 570 0.06 34 4 3 2 5 15 49 1 49 O O 0 MUA CORRIDORS 980 0.06 59 0 1 0 1 0 0 0 1 59 0.8 74 ry Q 100 30 outside air system per floor TOTAL(Vot) 594 Q LLL �- x 3 floors = 1,782 Y Q -- W O [1] From GMSC 2014 Mlnlmum Vendlatlon Rate Table 403.3 TOTAL MUA = 2,700 CFM LL [2] Expected peak occupancy = Area'Occupant DenW/1000 V Y U) 01-1 [3] Expected average occupancy Including Intermittant or variable occupancy per ASHRAE standard 62 IL W [4] Vbz=RpPz+RaAz n- [5] From OMC 2014 Minimum Ventilation Rate Table 403.3.1.2 z [6] Voz=Vbz/Ez O [7] Primary design air flow from air handling unit f� 8 Zp=Voz/Vpz W n O z r D 2 7 Q U VENTILATION CALCULATIONS PROJECT NO. 17055 06.20.2019 5 0 3 w U J O aR' W F O Z O O W 2 W� wC J K 6 h rt x z 0 M00050 �E aW $w a ii (moi C461 ,11 F13N%73 KEYED NOTES ® 10 DIGITAL SIGNATURE 1 COORDINATE ROUTING WITH ELECTRICAL TEAM. DO NOT INFRINGE IEF ON NEC CLEARANCE REQUIREMENTS ABOVE PANELSE TC. 2 CONFIRM INTAKE AND DISCHARGE CONDITIONS, LOUVERS.UL RENEWS: 06-30-2020 i } LISTED FLUE PRODUCT, ETC. I ' "ii�E PyG ! � I 3 � W cYI�Y+PA WwB,rvnn• gwter PnsoE swum I� 'r 1 �v :S��a[[No 112��emow,r cls�sll. FRED E.$HMII�,�E.�P 2lWPra�O�E�"v�Mue.ME PC r { 4I f- - - - - - - .- - .- - - - - - - - - - _ _. .- - ._ - - - - - - _ - - - _ _ - _...._...._..___._-__ ..._ _..................._..............._.... ........__� .__ _.-.-_.-__._-.-- ....-._._._._.-_....._...-... - - _- } ... -_ �- - - - - - .._. .... .... .._ .. ..._ _.- -._ ._.. ._ _ ._ - 1 � -_1 _...IT } R lil !I I Mot II II i III CRAWLSPACE •{ l } { I, I I I III l li AREA 2 III } I r i � fll III III I } � r I ifl III ill • I it I I COMM rr r 1- �I.—..__._..— �c{I� -I � IF ._.rJ r T Tlw:::�:.! I i •i + ' f I L 1 L I J ' 11r I! I I I {r� r —i ' I .. ... -- III a i .• et I t VJ I M � r•— •--I _11 .._ ...- - ---- ---. ..... .... .... ._. €._.. -, I-` CV = ` J {- W I D Z i a _ L - - - ry - I L- -1 L L_ ; ; ... .... v I- -I Q U) Lu oLL t= IL U ` U i Y I'I r - - - - - - -r - = W -__ L ! �....... .. ......... .. ........ .. ......... .. —_...... .. .... �.. _ _ ........._...._..._....__.._..........•..n _-_ __ .1� t 1 til l ....... .......-..-..... ` _l ._... _.... ...._. _._. I :I I I oo \..� ' } N ,Q aL _ CRAWLSPACE AREA i ': LJ� it I I I ce {� CJ ! F-- CD z L RADON MITIGATION SYSTEM DESIGN BY OTHERS •. I i r t — — — — — — — —`—-- —— — —— —r —FI T— — — — — — I I BASEMENT- HVAC PLAN WATERIFIRE I LOW II i I ELECTRICAL RISER )/OLTA� { 001 002 ; i PROJECT NO. FOUR GAS-FIRED - — — — — 003 jll i { 17055 DOMESTIC HW HEATERS ( II! 8"0 EA ) I .� JI 100 CFM 06.20.2019 9`0 EA ........... _ ...... .._.. —.._.._..-_----------------------__ 280 CFM / ! . . f. : 1$TAIR� ..._ ... � < I B-1 UH UH I 5 EF O I t i UH ; - \ B-1 0 B_2 i F I i-I 0_3 \ 0. PROVIDE 0,5 SF FREE—�� _�7. . _C` j EF p AREA LOUVER MAINTAIN 10FT BETWEEN B-2 g 18"xi8" EQUIVALENT FLUE EXHAUST AND I w COMBUSTION AIR INTAKE -PROVIDE 0.2 SF k /-" FREE AREA LOUVER /•` ( 12'x18" EQUIVALENT 1 �5 I �8 1 118" = 1'-0" M2000 BASEMENT - FLOOR PLAN - HVACo8._0' i8' 24'-0" 32 _a 0 r iii 4 6 7 9 ...... KEYED NOTES ci) 01r013%73 .. ........ .. DIGITAL SIGNITURE I EXHAUST LOUVER TO MAINTAIN 3FT CLEARANCE FROM pip OREGON 9�q 7 PROPERTY LINE,3FT FROM OPENINGS INTO THE BUILDING AND 10FT FROM OUTSIDE AIR INTAKES. ...... 2 KITCHEN HOODWITH INTEGRAL FAN&BACKDRAFT --- - - COMMUNITY RENEWS: 06-30-2020 2 AA ; - ROOM DAMPER BY OTHERS.GE AOW60SJSS BASIS OF DESIGN, 310 CFM MAX F13-21 3 PARTITION PLENUM TO SEPARATE HOOD&TOILET PROVIDE 1.6 SF FREE AREA EXHAUST IM AKA^oablkildE.GmlAti LOUVER. 18"x36'EQUIVAI-ENT 04 C" sdi 4 SOFFIT AS NECESSARY TO PROVIDE TRANSFER AIR PATH Fred E. Sh"a FCU FROM CORRIDOR WITH FSD. 1.1 5 PROVIDE CONDENSATE PUMP AND ROUTE 3148 SAMMO-700 3 CONDENSATE PIPE TO NEAREST TAIL PIECE OF SINK. 6 3145 CONDENSATE DN TO TAIL PIECE OF SINK. GROUND PTHP LU UH! UH FLOOR PTHP COMES WITH INTERNAL KIT TO DISCHARGE A SA18XI0-700 CONDENSATE WITHIN PTHP TO INDIRECT DRAIN. A 0 ---- - --- 7- A 7 COORDINATE LOCATION WITH ARCHITECTURAL. C -------- TRASH ACCESSIBLE ACCESSIBLE B B 34 125 UNIT UNIT ..t ! UNIT 01 60 ;;; . F1 02 1 F1 03 1 ............... Ims' E E K TYPE 5 ........ TYPE I ... .. ... TYPE 5 s. 5"o CORR: 110 ............... 126 —PROVIDE LOUVER FOR UNIT EXHAUST 0.5 SF FREE AREA TFF WC TOR 4 STAIR 12'x24"EQUIVALENT silo . : 8 F1 24 9 ....... E01-1 ------- TEF B B 4"o CORK Bay BATH EXHAUST IN WALL T ISA12X6-225 I cc .. .....- '13ROVIDE 0.6 SF FREE :t Lo Fi27] -- ----- .... .. ------ -- -- ---- ---- - --------- -- - ---- c AREA LOUVER. FJ-2-9-� RANGE EXHAUST I�SHAFT,TYP -------- -- ....-- --- ------ t j a 11rx24! EQUIVALENT BIKE A18X6-370 ROOM 6 LOUNGE FSQ F137 z EA W8 BIKE F1 36 .......... t ELEV 4 : 185 OFM ROOM M902SA 0 OFFICE F03 121 80 or) 0 a SBBX8-220 ............ CORRIDOR MECHANICAL SHAFT CN N 2 31 E 80 UNIT 7 W SEBX6-i00 RA24X12-370 0) ........ .. ...... .. ........ .. .... LA RY Z ()f ca D RB'12X12-229 TYPE: 6 12 ... - 0 0 .JANITOR 0 RA22X10 cr R812X12-100 -Ar-� . : .... ..... - - - - - - - - - - - - - - - - - - - - -1E LL LL FCU I F ------ PTHP u- 1-2 \_L4j LLJ c < wamd f': Lu UNIT UNIT_ PROVIDE LOUVER FOR UNIT LL EXHAUST 0.5 SF I IL) PROVIDE LOUVER FOR UNIT EA F1 10 F1 06 1 FREE EXHAUST 0.5 SF FREE AREATYPE 1 uj 12"X24'EQUIVALENT PTH TYPE 2 12"x24m EQUIVALENT ---- ----------......... 3: W C (D 2 Z PROVIDE 0.3 SF FREE .01 t 00 F ........ ........ .. ........ AREA LOUVER CU ........ 12"xi8"EQUIVALENT PTHP ACCESS]B[E* ........ . ...... uj U) '"o UNIT 0 3 PTHP EF "0 FlOE171 4 EF 4"0 0) 01 r C 1-13 UP 1-5 UP TYPE t. .. ..... . ...... G z - - ------ -- -------- - ----- ....... .. ----... . ........ .. . . ..... .. ... ... .. ....... ....... . ........ . EA ICORR EF 7'0 CORRIDOR MECHANICAL SHAFT F128 1-2 Up DBF 8no EA UP GROUND FLOOR-HVAC PLAN H .... . ..... . ....... .. ........ . --------- ------- DBF 8'0 SA1 2X6-2 _...� i £ LIP UNIT • F107 PROJECT NO. 17055 FSO TYPE 2 PTHP 06.20.2019 UNIT ....... PTHP F1 0-8 1 (D STAIR ° D A. TYPE A ... . ......... - ... ..... ... ..........j . .. ......... .. ..... . ........ -- ....... . .. .... PROVIDE LOUVER FOR UNIT .......... ........ ........... EXHAUST 0.5 SF FREE AREA 12'x24"EQUIVALENT ti Im ACCESS S UNIT IB T LE TYPE n E 5 r-I (D 2 wl,3 8 5 10 11 x N GROUND FLOOR - FLOOR PLAN HVAC SCALE: V8"=1'-0' 0 81-0" 16.Oil oz 24'-0" 32.-0" M2 . O1 4) 6 7 ( 9 i) � / _ - KEYED NOTES ® 0373 10 DIGITAL SIGNITURE PROVIDE LOUVER FOR UNIT .::ct RUST D.5 SF FRE AREA ( 1 EXHAUST LOUVER TO MAINTAIN 3FT CLEARANCE FROM �EXH E ,_.., ._... . UNIT �;, f 181'x18"EQUIVALENT PROPERTY LINE,3FT FROM OPENINGS INTO THE (AA 213 d FSD BUILDING AND 10FT FROM OUTSIDE AIR INTAKES. RENEWS: 06-30-2020 PTHP 6.01 : ';': _ '.; 4 3 ': 2 SOFFIT AS NECESSARY TO PROVIDE TRANSFER AIR PATH D TYPE 4 M902 SA' FROM CORRIDOR WITH FSD. FSD ( 8NfNF,eu E 4 . 1ppvv j-� ' �gQeleu�:iU�eeJn,mm. M902 SA' Fred E 5`toagg, «E. CORRIDOR MECHANICAL SHAFT re ore 10q.M 2, UH 5 PTHP PTHP i PTHP ' 2-1 EA A B t 12X622 . . ..._.. .. ._..._.. _...! 1 r A UNIT t UNIT OR UNIT 1 BB1... 201 2-021203 K) Ra. Ei y i� 225 TYPE 1 TYPE 1 TYPE 1 +. 4 8"0 SA12X6-225 ,HEEK m 6.01 i EA UNIT "' CORR M I � l :::: 212 Ol :. 226 STOR i .... .... LLC PCP TYPE 1 ri.,.. 224 e„� STAIR 910 r i 01 _ _ ( g - - - -_ _ - - - - - - - ' B CORR I `'~— DE LOUVER FOR UNIT SA12X6-225 I PTHP UNIT ” ° 227 EXHAUST 0.5 SF FRE AREA r- �^ 211 1 i .... - :. .- 12"x24'EQUIVALENT E.... . _.._� C j �� 6.01 1 ' TYPE3 , . . .......... FSD r 11 8„0 8„� 90 3A v BIKE I M z Z I_ I ?: ELEV ROOM T -- 204 'UNIT 4 CORRIDOR f 0 MECHANICAL SHAFT M 03 221 . ...'�` .._ 6.01 _ :,,.- _ _. _ p d 04 PE fi EA h UNIT [ '.__..... .. ......_ - ---..-.-. -- -----_.. .. -------- -- -------- _ 2 LAUNDRY _ 205 Z L ` 6,01 co 223 J ITOR TYPE 1 0 C Q ¢ RA22XID I� , 22 /�' fY 3 _ EF PCP 23 d'0 2 40 PTHP EA EA ;ins UP UP C Y I— `� CA Lu PTHP 1 I PROVIDE LOUVER FOR UNIT UNIT 1 UNIT 2 B '—PROVIDE LOUVER FOR UNITILL EXHAUST 0:5 SF FREE AREA 210 I EXHAUST 0.5 SF FREE AREA Y 601 i EF „ U) PTHP I 206 6:01 t 7 0 12"x24' EQUIVALENT U LL jJ 12°x24 EQUIVALENT TYPE 1 t•;' s 2-2 UP Y O C I TYPE 2 V = W p' ,- Z CD PTHP UNIT H 81.0 DBF I Q C 1 CORR {:_ . 1 8"PJ d 209 s Ot 228 _. i UP O TYPE 1 ;......: :. 1 O) z EA DBF 8,0 _..... . ..__.. -' G.7ti' O_ CORRIDOR MECHANICAL SHAFT I W : EA `� U ij SECOND FLOOR-HVAC PLAN - - SA12X6.2 e 8,0 2 UNIT i 6.01 ' 207 PROJECT NO. a._... FSD i 17055 TYPE 2 PTHP B SA M902 S"' 06.20.2019 1 = - ...... ...... .. . ....... .. .... . �..... . ...... .. _ ... ... UNIT q oN PTHP 208 .01 STAT I TYPE 7 02 1 I PROVIDE LOUVER FOR UNIT EXHAUST 0.5 SF FREE AREA —5 G 12"x24" EQUIVALENT rr1 N SECOND FLOOR - FLOOR PLAN - HVAC o D< 24 .0° 32 M2002 �g ua 4 6 7 I 9 111 ` II III 01�0%373 .. ...... KEYED NOTES G) DIGITAL SIGNITURE PROVIDE LOUVER FOR UNIT EXHAUST 0.5.,SF FREE AREA 118"1 EQUIVALENT 1 EXHAUST LOUVER TO MAINTAIN 3FT CLEARANCE FROM ...... UNIT PROPERTY LINE,3FT FROM OPENINGS INTO THE AA 313 FSD K BUILDING AND 10FT FROM OUTSIDE AIR INTAKES. RENEWS: 06-30-2020 1 4 PTHP 6.01 4 3 2 SOFFIT AS NECESSARY TO PROVIDE TRANSFER AIR PATH D TYPE 4 mon SA! FROM CORRIDOR WITH FSD. FSD 4 1 I u6eLh Fmd bU �*VES� E Sh"t, Fred E. m902 SAi �&-K Aposion;Mr opmArpg th[s CORRIDOR MECHANICAL SHAFT im ..........-.... PTHP PTHP A 12X6- /4) A TOR %BB 'if UNIT 325 UNIT UNIT &.0 TYPE 1 EE F30-1 � QD 8 k-�--- F302 F303 I sAl2X6-225 TYPE I TYPE 1 4 1 ;;; F-A ............ .......... UNIT - CORR ....... ...... F32-6-1 STOR ""J F3121 PTHP ... ....... C TYPE 1F324-1 STAIR 8..o ............... ......... N .................. ...... (D B ..........: B ...... ROVIDE LO CORR EXHAUST 0.5UVER SF ER AREUNITA ,cc PTHP UNIT F327 ISA12X6-225 12"1 EQUIVALENT c .... ... ........ . ........ . . .. ......... .. F31 1 Ot TYPE 3 FSD 8110 r4 .......... - -—--------------- z won" BIKE ELEV D ROOM co 0 F-0-3-1 321 CORRIDOR MECHANICAL SHAFT 8110 C4 7 04 UNIT I-- ......... UNIT EA; N 0*) F305 .......... . ...... ....... .. 2 LAU R D F,—o4j z TYPE 1 1( 0 < TYPE 6 0 u- F3231 .,. .. . ANITOR RA22X10 co: r----r I p EA If 322 0 ri E PTHP EF EF PTHP < LL (D Li- C 3-3 3-4 C < LIJ 8.10 A PTB IW 4"0 UP 4"0 UP LLI 0 EA UNIT UNIT PROVIDE LOUVER FOR UNIT ILL 311 I F3-06-1 2 I EXHAUST 0.5 SF FREE AREA PTHP 6.01 12'x24"EQUIVALENT n W TYPE I TYPE: -ro UP m w t 81.0 Z F . ....... ... ....... ... ........ . to op EA DBF (o up < PTHP UNIT C Ii i DBF 8`0 0 F3097 .01 .............. 1 UP TYPE 1 ----r. z vlo G ............ .............. CORRIDOR MECHANICAL SHAFT EA 1 910 HTHIRD FLOOR-HVAC PLAN itUNIT i 7307 PROJECT NO. FSD PTHP TYPE 2 17065 SA 4 B WM2 I 6.01 06.20,2019 ......... . ........ ........ . ........ .... .. ...... ------ UNIT TYPE 7 t 17 .. .. ........ . .. ..... . ....... ... .... .. .. ....... .. ... . .... .. ..... .. . .. . . . . . . ... .. ... ......... ... . . ...... . .. ... ...... --- PROVIDE LOUVER FOR UNIT EXHAUST 0.5 SF FREE AREA 12')L241 EQUIVALENT 3 5 2 : 10 N z 1/8 -011 THIRD FLOOR FLOOR PLAN HVAC z N%w �Q SCALE: 1/8'= Vi 0 a,-c" 16' 0" 24'_0" 32'-0" M2 . 43 ii iii 4 6 7 9 11 010373% KEYED NOTES a:) DIGITAL SIGNITURE (D ROVIDE LOUVER FOR UNIT EXHAUST 0.5 SF FREE AREA I EXHAUST LOUVER TO MAINTAIN 3FT CLEARANCE FROM BUILDING AND IOFT FROM OUTSIDE AIR INTAKES. ----- ........ .. . ...... UNIT .i 18"x18'EQUIVALENT PROPERTY LINE,3FT FROM OPENINGS INTO THE IEF FSD RENEWS: 06-30-2020 (AA : F41-3-1 2 SOFFIT AS NECESSARY TO PROVIDE TRANSFER AIR PATH PTHP01 �3i FROM CORRIDOR WITH FSD. D TYPE 4 L... M902 SA; gAµj FSD ox C-m Fred E. S uR- 4 1 .02 M902 SAI CORRIDOR MECHANICAL SHAFT PTHP PTHP 41 EA A ffi i Al2X6-2 ....... . .. ........ .. ......... .. ......... A TOR UNIT UNIT BB )------ UNIT F4-0-2-� P-0-3 1 425 1 F4-0-11 TYPE 101 TYPE I TYPE S 12X6- wisizEEK 4 8.0 EA UNIT CORR EQUIP. --------------- F4-26-] Room F412 PTHP -47 ....... 1 6' Q F42 TYPE 1 01, STAI 8.10 C 860 ............... - ............ FO 1 ............... .. ......... .. ....... ......... ...... . ....... will I P11 B . ......... ... ......... ...... B --- -- -------- Aa) ..... .. CORR ROVIDE LOUVER FOR UNIT SA12X6-225 ...... UNIT 427� EXHAUST 0.5 SF FREE AREA ------ /PTHP\ F fcc 1 Tx24'EQUIVALENT C f 411 1..... .. ........ TYPE 3 600 FSD4 2 ....................... z nn" BIKE --- - j M902 SA ELEV U) ROOM ........ 421 Z) CORRIIII MECHANICAL SHAFT (y) 0 ---------- . ...8..... r "0 7 UNIT W L--------- EA' 717 UNIT CA 7405 4 _j .......... D ........ -- -------- . ...... .. . LAUNDRY ai 6.01 Z 1�� JANITOR TYPE1 TYPE6 0 0 JA RA22XiO t EA O — - — - — - — - — - - E ............. < ILL. EF LIJ PTHPC 4-3 ZEN\ PTHP 0 (D u- U) uj UP Ono PTHP 4'0 UP 4- B. LLI 0 UNIT ffi 1 \7 DE LOUVER FOR UNIT LL UNIT 2 F4-1fl EXHAUST 0.5 SF FREE AREA CORRI U) PTHP 112"x24"EQUIVALENT TYPE1 F406 6.01 CL LLJ F428 TYPE 2 EF 7-0 c IL \±2 Up M LU ......... 8.10 ......... .. ..... .. ..... ........ ...... ... 00 F : DBF 00 wo UP PTHP UNIT LLI DBF goo }- 409—1 ............. a) IN ...... UP h_- TYPE1 . ........ .. ... - -- ------- -- -------- . ....... 8"o - --------- CORRIDOR MECHANICAL SHAFT EA H ......... ...... .. .... .. .. ......... FOURTH FLOOR-WAC PLAN SA12X&&-2 ..o UNIT .... 407 PROJECT NO. TYPE 2 PTHP 17055 FSD SA IV 4 M902 06.20.2019 .. . .. ........ .. . ........ .. .. .. ...... .... ... ........ .. ......... ... .......- ..... . ... .. ........ . ...... UNIT PTHP 448 STAIR 5 G ------- TYPE 7 F02 7- . . ........ . ...... ........ .. .... .... .... ........................................... .... .. ........ .. ------ ... ... .. ........ ....... ......... J PROVIDE LOUVE1R'F'OR-UNIj EXHAUST 0.5 SF FREE AREA 12"x24'EQUIVALENT q (D 2 3 5 Ill N 1181, 11.011 FOURTH FLOOR - FLOOR PLAN HVAC F688JEW5 m--m SCALE: 1/8'=V-0" 0 8'-0" 16'•0" 24'_0" 32'-0' M2 . 04 -- (4)5"0 RESTROOM EXHAUST DUCTS AND (8)5"0 RESTROOM EXHAUST DUCTS AND (4)5'0 RESTROOM EXHAUST DUCTS KEYED NOTES ® � 10373 r .......... t 5 6 " 7 (4)8"0 RANGE HOOD EXHAUST DUCTS (4)8 0 RANGE HOOD EXHAUST DUCTS EA © DIGITAL SIGNATURE "•«` •_,_ .. --�-'- :�=-_"""- I` 1 HORIZONTAL DUCTWORK IN ATTIC SHALL BE ENCLOSED ,JFA OREGON 9,�q INA RATED SOFFIT,CONTINUE SHAFT RUNS TO AHU 2l, CONNECTION POINT EXTERIOR OF BUILDING. ARCHITECT TO CONFIRM. 3 RENEWS: 06 i 2 LAUNDRY DRYER VENTS.EIGHT TOTAL AT 800 UP EACH. i 3 LAUNDRY ROOMS EXHAUST.FOUR TOTAL AT 7'0 UP EACH. + ^r'Ar°1. 1 •••.� r•• �.-- \ ql tSiVK3C Mol 4 JANITOR ROOMS EXHAUST,FOUR TOTAL AT 4'0 UP EACH. FRFD E.SFW$.#IF. vtgR (E� (7 5E ROOMS EXHAUST.FOUR TOTAL AT 4'0 UP EACH. «► M•�• BIX +��Wwa•la: , y 6 ROUTE EXHAUST DUCTS OVER THEN UP TO GRAVITY RELIEF HOODS. 16x10 DN ! ._ 6 ROUTE EXHAUST DUCTS AROUND SA DUCT THEN UP TO GRAVITY "' RELIEF HOODS jj 1 1. L 2 iEKpm q w Ir~ ., (7)5.0 RESTROOM EXHAUST DUCTS 4 I i v I I I (5)8"0 RANGE HOOD EXHAUST © l 1 1 i I .J.~ .. ... ..... ... .. .. ...... .. .. .. ' 1 t N ' _i I I : I 1 1 ' co UP TO VENTILATION UNIT 16x10 SA DN MAUIR-1 (7)5'0 RESTROOM EXHAUST DUCTS AND 3 (7)8'0 RANGE HOOD EXHAUST DUCTS EA I : ............_..,.......... _...........__._._..---._...... 1 Ur 26x14 z S4: ; a... M I L._...._._..__....._«.._._._" O ..........._.... ..._. ... ........_. ...._......._.......L N 2 -- - - W 4 '---... .. ._...' -------- - -----.. _. .___.. .. ....... _ ......... ._. .. ......... .. ........- .- __._... .. ..._ __- -- --- ._... ._ .... _....,.. _....... .. ......... .. ....._... .. ....... .._..-- - '----- - --... ..... ..... ....j -- ---. Q : _ . --------- .. ..... . .. _.. . ...__. .. _ . ( .... _ .. _ . _ _ - ..__ .- _ - . ......... . ... . .. .. ..... .. ......... _ ........ ....... : i ; f - 3 4 5 OCD u- I W Y � Q jLpLLJ (3)5"0 RESTROOM EXHAUST DUCTS AND Wo �' EA (318"0 RANGE HOOD EXHAUST DUCTS Y LL I Y a W i V )- W -' - ........ .. ........ .. ......... .. .....«_ .. ......... _. . -.... ... .......... . ..._.... .. .......- - -- ------- -- -- .. .. ... ; . .. _. _ .._.... _ ....... 00 (8)5'0 RESTROOM EXHAUST DUCTS ANDco (2)8"0 RANGE HOOD EXHAUST DUCTS ! 2 6 (8)5"0 RESTROOM EXHAUST DUCTS AND EA (8)8"0 RANGE HOOD EXHAUST DUCTS ^ I.L. rn W LEGEND Q - - . ... ... - I ,. _ ._...... C) CG)._... .. ._..._ .. .. .. ....... . ._..._ -. .._... .. .._..... .. ._.... -..._ _..... .. ...; . - - DN DOWN z r MAU MAKE UPAIR UNIT i SA SUP LY AIR O EA EXHAUST AIR V - �� _ ...... ... ....._..!.. ._.__. ._ ......... .. ........- .. ......... .. .._.._ _. I . .. ._...._ .. . - -- AT HVAC PLAN " 16x10 SA DN 1 PROJECT NO. 17055 i; 06.20.2019 i ' I I 5 jE I I � Wo C 1 , 0 zz 3) 5 J1 a r z N 1181• = 1'-01' ATTIC - FLOOR PLAN - HVAC SCALE: 1/8'= l'-O" M2205 $o 0 8'-0': 16'-0" 24'-0" 32'-0 3� i i iii 4 8 7 9 11 ^37t3 KEYED NOTES ® 5 6 I DIGITAL SIGNATURE 1 PROVIDE GRAVITY RELIEF HOOD.GREENHECK WRH OR EQUAL. s OREGON q EA EA THROAT SIZE 22'x30'NAN. ,� xcAT 2i 1°1�� - - I 2 LAUNDRY SIZE i6 VENTS. EIGHT TOTAL AT WO UP EACH.THROAT AFD S�Q AA I 1 I ( 3 LAUNDRY ROOMS EXHAUST.FOUR TOTAL AT 7"0 UP EACH RENEWS: 06-30-2020 THROAT SIZE 16'x18'MIN. t 11 ( I I I I ;y??1 <t; ' #dcr engin e.sx"u 4 JANITOR ROOMS EXHAUST.FOUR TOTAL AT 4°0 UP EACH. � _- � I 1 I THROAT SIZE 14"X14'MIN. ° ' "C' ^ !u enYlGlS 2 le t } I I I I I 5 BIKE ROOMS EXHAUST, FOUR TOTAL AT 4'0 UP EACH. FRED E.s F � �a THROAT SIZE 140x14' MIN. a . : .«."a S MAINTAIN 36'CLEARANCE FROM CU-1 CU-2 AND MAUIR-1. zc; ,o�j<"-}<A'i0{1iPS�11116410!! I I I 1 f - - - - - - - - - - - - - - - - --- ROO O t , I L \ H l M903 EA / LLC 2 CU , 1� M903 R-2 � I J 1 r— ` 1 RL 2 CU I _--- © PV INVERTER I I I I rn MUA I I >C I � i 5 1 I it M903 R-1 Ir _v I I I I I i cf) o 28x20 DN UJ I c\1 ZZ 3 s O I 1 N J p - - -- -- I I I NO EXHAUST OR VENT IN THIS AREA RDD I I ® RDO t I 0 o Q OSA INTAKE 10' SEPERATION Q I I Q I ;Q f I -- - - - - - - - -- - - - - - - - - - - - - - - - - - -- - -- -- -I- - - - -- - - -- --Io 0 < LCL. LJJ I f � g 1 1 7 9 W �- � I I I W 1 � EA M903 I EA M003 1 I I I � wo M903 EA I ,Y I I I I w L1.. Ua U w 2 e I Y w CL EA M9D3 I I V = w F - — - — - — - — - — - — - - ' - - —- — -- co Lu a- M903 EA I I I I I LEGEND CD - — _ -- - -- - - --i - - - - -_ - - - - - - - - - -- i - -- -1- - - - -- - - RH ROOF HATCH � Z RD o D RL ROOF LADDER OVER PARAPET Rt I 1 I RDD ROOF DRAIN 1 I 1 I 1 I I MAU MAKE UP AIR UNIT V I I I I - - - - — -- - - - - - - - - — I- I I 1 I CU CONDENSER UNIT I ROOF-HVAC PLAN 'D 1 EA LOUVERED PENTOUSE FOR EXHAUST AIR RO I I I I I I PROJECT 055in NO. 1 I 06.20.2019 I f I I I I - - - - - ---- - - - - - -I- - - ----- - - - - - - - - - - -- - -- 1 - - - - -, - -- - --- I I I I I I 1 1 3 I I I a I I I I I I ! I t s 1 2 3 5 8 10 11 ` ROOF - FLOOR PLAN - HVAC M2 . 09 1 SCALE: 118"=1'-0' 0 3'. ��-a° 24.-0" 32'.0 8w a 01013%73 DIGITAL SIGNITURE rSA 4 M903 RENEWS: 06-30-2020 :�U�*vd bV Fmd E Shaw Fred E. S - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 26x 14 2- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ROOF W21 00 W15 D?W 16x90 16x90 16xlO LATTIC Two FSD/OBD/GRILLE FSDIOBD/GRILLE FSD/OBD/GRILLE T4 WA -CORRIDOR- 225 CFM 1 N +1- 225 CFM T4/- 225 CFM — - - - - - LEVEL 4 FSD/OBD/GRILLE MD DIGRI LE FSDIOBD/GRILLE Z 225 CFM +1- 226 CFM +1- 225 CFM U) (y) 0 ti Lu ZLY_0 0 < "(0 0 LEVEL 3 0 < ILL (D LL- LLI FSD/OBDIGRILLE FSDIOBD/GRILLE FSDIOBDIGRILLE < +1- 226 CFM +1- 225 CFM +1- 225 CFM ED o LL YU) [L w LIJ -17 LIJ IL 0 Z cc [- < Lu 0 a. 0� — — - - - - - LEVEL 2 ar z rFSD,IOB DIG RILL E FSDIOBD/GRILLE FSDIOBD/GRILLE OB L IF L +1- 225 CFM +1- 225 CFM —:f�+I- 225 CFM 0 C) SUPPLY DUCTWORK RISER DIAGRAMS PROJECT NO. 17D55 LEVEL 1 06.20.2019 STAIR MECHANICAL SHAFT MECHANICAL SHAFT MECHANICAL SHAFT STAIR NOTE: TEST & AIR BALANCE TO ADJUST TO POSITIVE AIR PRESSURE IN CORRIDORS. TEST WITH EXHAUST FANS AT LOW SPEED, REFER TO MO.02 & MO.05 FOR AIR FLOW RATES. 0 z 9 SUPPLY AIR RISER DIAGRAM SCALE: NONE z o� M5 , 01 ~ 1N F 107 NOTE: DIGITAL SIGNITURE ,pFp OREGON ,\q ROUTE 4 OUT SIDEWALL EXHAUST. �� r 21, �9 �� Fp E S�,F RENEWS: 06-30-2020 TYPICAL EXHAUST RISER EA EA EA 1 2 5 6 7 4 ';weyx�y 9xs6 by Fr E SMub DN:C4 . "`" y��r3sub�uselnal.mm. 3 LOUVERED 3 Fred E. Shau , ;m=�u M3 PENTHOUSE REFER TO TYPICAL EXHAUST RISER NOTES M3 REFER TO TYPICAL EXHAUST RISER NOTES 5 RESTROOM EXHAUST (5'DIA.) KITCHEN EXHAUST(B"DIA.) ROUTE IN EXHAUST AIR CHASE EXCEPT IN 3 ROUTE IN INDIVIDUAL RATED SHAFTS SUPPLY AIR CHASE ROUTE IN STUD WALLS. M903 (TYPICAL LEVEL 1 &2) UL LISTED FIRE STOP PENETRATION. REF OSSC 713.11-ARCH TO CONFIRM (TYPICAL ALL LEVELS) *Af- REF OSSC 717.6.1 THROUGH PENETRATION *0_ --Ar> EXCEPTION-ARCH TO CON FIRM IL - - - - - - - - - - - - - - - - - - - - - - - - RATED ASSEMBLY ( ) TEF RESTROOM FAN �. NON-RATED SOFFIT 1 (TYPICAL) (TYP} ATTIC RANGE HOOD W/FAN BY OTHERS (TYPICAL) d a d d Z LITCHEN EXHAUST(8" DIA,) fn DIRECT ROUTE TO ROOF D (TYPICAL LEVEL 4 HOOD ONLY) LEVEL 4 N ° W U) —j ED TEF RESTROOM EXHAUST(5'DIA.) O O Q 1 FIRE DAMPER (TYPICAL LEVEL ONLY) �' O C7 a c� d v < LL F-- KITCHEN EXHAUST(8'OIA,) Y ~_ Q U) 7Lu FIRE DAMPER (TYPICAL LEVEL 3 HOOD ONLY) Lu O L 0 REF OSSC 717.6.1 THROUGH PENETRATION-ARCH TO CONFIRM LL LEVEL 3 � = W a p � z �- °w � � U) CD � oZ 0 U LEVELeeEXHAUST DUCTWORK RISER DIAGRAMS PROJECT NO. n a 17055 CJ 06.20.2019 TYPICAL LEVEL 'I STAIR MECHANICAL SHAFT MECHANICAL SHAFT MECHANICAL SHAFT STAIR g S EXHAUST AIR RISER DIAGRAM - KITCHEN, DRYER, TOILET M n ^ SCALE: 12"= i'-0" S24oz 5 . O L 0*� Nte PROFFsf 1 lls"gtm— KEYED NOTES D 373 FROM 2nd FL DIGITAL SIGNITURE 1 8 m UP M905 1 SEE ARCH SPECS FOR MAXE/MODEL.CENTERED IN ROOM. rap aREGON��a 1 D 1- - - - - - - - - ; - - — - — - FROM 1 st FL S CH COORDINATE WITH ARCHITECTURAL RCPs. j 8'm UP TEF 2 KITCHEN HOOD WITH INTEGRAL FAN K BACKDRAFT DAMPER � O BY OTHERS.B.O.D.IS GE JV338HWW 170 CFM MAX. RENEWS: G6-30-2020 . 5'a UP FROM 2nd FL ,. 3 3 KITCHENITOILET DUCTWORK UP TO ROOF. REFERENCE AIR {i CH 5°m 8`m UP 0 — 8'm UP 1 FROM 1st FL 5"m UP i' .�,f RISER DIAGRAM FOR RATING REQUIREMENTS. a 4 SEE FLOOR PLANS FOR PTHP SIZES. I COVE 5 T TO PTHP&ROUTE TO :oMd errrcae artExeai HEATER TEF 2 Fred E S �uii` E .. ... ........ ......._ _ .__.-. _ SINK. GROUND n..�::�.000+�".. -_. .. ..._._ .. ... ... - - _ . .._... . -....... _ ...1. .. . _ M@R5 _. `s.•-i` 314°CONDENSATE RISER CONNEC I I CODE COMPLIANTTERMINATION 6 314'CONDENSATE DN TO TAIL PIECE OF �. 's 'M'Q' -- T FLOOR PTHP COMES WITH INTERNAL KIT TO DISCHARGE VARIES BY UNIT CONDENSATE WITHIN PTHP OR EXTERIOR. 8'm UP AND FLOOR. T 7 ROUTE KITCHEN HOOD OUT SIDEWALL LOW _. ER. ..... .............. 3O - - - - - — SEE NOTE. - - - - - - - - - - - - - - - - - - T VARIES BY UNIT Tim AND FLOOR. SEE NOTE. M8D4 UNIT 'm F31-0-18'm 8 0 TYPE 1 s + Q 4 t► M904 r EEK UNIT PTHP PACKAGED TERMINAL pT}� M;; ,� k ; "'°'z 307 HEAT PUMP C 1•:; 04 - .°._s TYPE 2 �Lc �- -F I ® I ....LL NOTE: NOTE: PROVIDE SIDE WALL EXHAUST FOR & 304 PER ROUTE DUCT PER DRAWINGS M2.02,2.03 AND 2.04, KEYED NOTE(T)ON M2,02,2.03 AND 2,04, Z U7 D HVAC - UNIT TYPE I (ANSI TYPE 1131) HVAC - UNIT TYPE 2 (ANSI TYPE 1131) M o N = SCALE: 1/40 V-01 SCALE: 114' = T-0" 0 W m Q 0 ry 0Y O V Q ~ W LL OL W j rt�t w 4- 1 B - ._ .. ......... .. ........ .. ..__... _-..._ _...... .. ......... .. ...... - ._ .. _ _ M O UNIT PACKAGED TERMINAL ® UNIT ! O ii_ - Lu U) HEAT PUMP i ,"" a 313 VARIES BY UNIT r W 311 � f € + _ : + PTHP TYPE 3 TYPE 4 'AND FLOOR. , `: t I _... }- I ,�-- —' CKW4 �._ PTHP % SEE NOTE. 7m 11 J 2 D PROVIDE LOUVER O FOR UNIT EXHAUST D 0...._... ..... ._...... 8"m MI I FREE AREA M904 •- MINIFREE 12°x24' VARIES BY UNIT T EQUIVALENT O AND FLOOR. T U T SEE NOTE. ENLARGED PLANS CH 8'm UP 5"m PROJECT NO. TEF ( 17055 Mgos 1 5"o UP w COVE (TDEF Msos - : - - 06.20.2019 HEATER CH 5"mOo 3 8`0 UP ...... FROMistFL ,....� i FROM 2nd FL _ ........ .. ......... s s NOTE: NOTE: T ROUTE DUCT PER DRAWINGS M2.02,2.03 AND 2.04. PROVIDE SIDE WALL EXHAUST FOR 0& ®PER KEYED NOTE©ON M2.02, M2,03 AND 2.04. x N HVAC - UNIT TYPE 3 (ANSI TYPE '13 ) HVAC - UNIT TYPE 4 (ANSI TYPE 'B') M6mOl SCALE: 1/4'= 1'•0' SCALE; 114"=1'-0' 3� ����`%I N['c?4 o� ( 4 5 } � 1 KEYED NOTES ® 0 10373 of, . -� 5'e UP DIGITALINITURE I 1 SEE ARCH SPECS FOR MAKEIMODEL.CENTERED IN ROOM. kw _ _ _.._ --_.. - _.. _._ _ ._ �. COORDINATE WITH ARCHITECTURAL RCPs.-(1c42 KITCHEN HOOD WITH INTEGRAL FAN&BACKDRAFT DAMPER BY OTHERS.B.O.D.IS GE JV33BHWW 170 CFM MAX. I i RENEWS: 06-30-2020 3 KITCHENITOILET DUCTWORK PTO ROOF.REFERENCE AIR J r l`- ' RISER DIAGRAM FOR RATING REQUIREMENTS 1H i 4 O ' I 5"e 7il 4 SEE FLOOR PLANS FOR PTHP SIZES.b 5 314'CONDENSATE RISER. CDNNECT TO PTHP&ROUTE TO FfBtl E.$6TEFCODE COMPLIANT TERMINATION.M04 M905 6 314'CONDENSATE DN TO TAIL PIECE OF SINK. GROUND k. CH FLOOR PTHP COMES WITH INTERNAL KIT TO DISCHARGE _. I CONDENSATE WITHIN PTHP OR EXTERIOR. M904 ;; j T 1 7 ROUTE KITCHEN HOOD OUT SIDEWALL LOUVER. COVE ` I`...... '€ HEATER !ACCESSIBLE ' UNIT . .....--..._...... ._........-- — . .... ... ... .... - 101 VARIES BY UNIT T T r T AND FLOOR. 5 TYPE 5 SEE NOTE. Mss4 g^a i III I E UNIT O I t — 5'e UP / 6'o I �— .... ... .._....304.. . .. - .. . _. .. . . .-._... .. _.......�� _ ... . . ........ .. ._.. . .. ....... .. . - - _ _. _.._... _ ....._. TYPE 6 ® s 2 I TEF 2 11 Mss4 - ' 1 A19D5 VARIES BY UNIT I' B 0 { I B"m UP AND FLOOR. —..............____.. SEE NOTE 6 { o _ _ _ co o T M906 PTHP PACKAGED TERMINAL HEAT PUMP ( i Z NOTE: NOTE: (n PROVIDE SIDE WALL EXHAUST FOR0© PER KEYED NOTE m PROVIDE SIDE WALL EXHAUST FOR 104 PER EY D NOTE 1 CD 0 ON M2.01. ON M2 01. N = !!7 0) J co HVAC - UNIT TYPE 5 (ANSI TYPE 'A') HVAC - UNIT TYPE 6 (ANSI TYPE 'B') o o Q 1 SCALE: 1/4'l=V-0" SCALE: 174"=1'-0" EnIf 0 o () LL LiLi w ~ ' 10 LL F j % 1 ------------ 0 = W 0— CH Ii 5'e i 5"o UP O Z 00 1 e I COVE ? HEATER TEF 2 LLI d. T _ o } { z ; i r U CJ - O ENLARGED PLANS 5 '' - UNIT 1� ' i i PROJECT NO. PACKAGED TERMINAL@pp) 308 STAIRHEAT PUMP TYPE 7 VARIESBYUNITjTo 0217055 AND FLOOR.SEE NOTE. 06.20.2019 4 ' \ .. .. ..�I.......... o � M�5 PROVIDE LOUVER FOR UNIT EXHAUST C.�. 0.54 SF FREE AREA g MINIMUM 12'x24' EQUIVALENT S w HVAC - UNIT TYPE 7 (ANSI TYPE 'B) � !2a 3 SCALE: 114'z V-o' M6002 B� rl�3013173F�ENTERLINE RADIUS EQUALS r SIZE OF DUCT DROP 1.5 TIMES WIDTH. NO DIGITAL SIGNATURE TO TURNING r� OREGON q MATCH NECK SIZE OF VANES REQUIRED, UNLESS �,F nr 1 �9 �� GRILLE(TYP) VD W. OTHERWISE NOTED. FD S�Q` V RENEWS: 06-30-2020 318" BOLT, �aY�➢E��u o,[t{{ NMgrY�m REFER TO UPPER LOCK VD FRED E.SHAU"E PE a Y a E 1Y1/J6�,RS.IK�ESY.PFf ATTACHMENT USE 45 a WASHERAND DEGREE MIN 36' BEFORE DETAIL NUT, THROAT AT TAP AND AFTER ELBOW VX20GA STRAP REFER TO UPPER 316" DIA. BOLT, ATTACHMENT LOCKWASHER DETAIL AND NUT. I CONDENSIN (TYP) 114"SEISMIC RESTRAINT —�_ II G ,= CABLE TO STRUCTURE LESS THAN 15 DEGREE TYP UNIT 2X2X16 GA ANGLE (TYP) 28" DIAMETER 30 DEGREE MAX REFRIGERANT LIQUID LINE ON ROOF REFRIGERANT SUCTION LINE. MECHANICAL PROVIDE REDUCER INSULATED ENTIRE LENGTH REFRIGERANT VALVE(TYP) FORGED WIRE AIR FLO UPSTREAM OF Cam 5'-0' MAX TO ROPE /� BRANCH INLET WITH FILTER DRIER WITH REPLACEABLE STRUCTURA CLIP, INSTALL TWO ALUMINUM JACKET EXTERIOR CORE. VERIFY USE WITH EQUIPMENT L PER CABLE END CONICAL OR TO MANUFACTURER. SUPPORT (TYP) RADIUSED WYE LO-LOSS 45 DEGREE BI��DIN VIBRASORBER VIBRATION ISOLATOR(TYP) t� FITTING XCESS CABLE Ait LTERNATE:SQUARE PROVIDE REDUCER AT RS SIGHT GLASS MIN 1"(TYP) ELBOWS WITH TURNING CONNECTION PIPE SUPPORT AT 48'OC(MAX), NEOPRENE COLLAR CLAMPED 2-112'X12 GA STRAP 1" MIN VANES ALLOWABLE 70 GRILLE WHERE BRANCH DUCT TO STRUT, PROVIDE 6' LONG THERMAL EXPANSION VALVE WHERE DUCT VELOCITIES IS OVERSIZED SADDLE AROUND INSULATION. WITH SHOWN WITH TRANSVERSE BRACING SHOWN WITH LONGITUDINAL BRACING ARE LESS THAN 1500 FPM, (TYP) EQUALIZER, VERIFY USE WITH EQUIPMENT MANUFACTURER. NOTES; NOTES: TRAP AS REQUIRED BY DXCOIL 1. HANGERS SHALL BE INSTALLED AT EVERY CHANGE OF DIRECTION AND NO MORE THAN 10'-0"APART, 1. PROVIDE DUCT LINER AND/OR EXTERNAL DUCT INSULATION AS NOTED ON PLANS OR IN EQUIPMENT MANUFACTURER 2. PROVIDE A FLEXIBLE CONNECTION BETWEEN MECHANICAL EQUIPMENT AND DUCT. SPECIFICATIONS. 3. STRAP MAY BE REDUCED TO 1"X22 GA FOR DUCT 24"DIA.AND LESS IN DIAMETER, 2. PROVIDE HANGERS AND SEISMIC BRACING PER SMACNA AND BUILDING CODE. LIQUID LINE 0 4. SEISMIC RESTRAINT CABLES MAY BE OMITTED WHERE DUCT IS SUPPORTED WITHIN 12"OF STRUCTURE AS 3. LOCATE MANUAL BALANCING DAMPERS IMMEDIATELY DOWNSTREAM OF EACH DUCT TAP. SOLENOID z MEASURED FROM THE TOP OF DUCT TO THE BOTTOM OF STRUCTURE. 4. MAINTAIN MINIMUM 36"CLEARANCE BETWEEN LEADING OR TRAILING ELBOW JOINT AND DUCT TAP VALVE 5. WHERE SEISMIC CABLE RESTRAINTS ARE REQUIRED, FITTINGS. A. PROVIDE SEISMIC CABLE TRANSVERSE BRACING AT 30 FT AND 5. TURNING VANES REQUIRED ON RECTANGULAR DUCT SYSTEM ELBOWS.SINGLE THICKNESS VANES UP B. SEISMIC CABLE LONGITUDINAL BRACING AT 60 FT. TO 25' HEIGHT AND DOUBLE THICKNESS VANES IN DUCTS GREATER THAN 25"HEIGHT. RADIUSED NOTES: O N C. SEISMIC CABLE RESTRAINTS ARE NOT REQUIRED AT EVERY HANGER LOCATION. ELBOWS MAY BE USED AS AN ALTERNATE. N = 6. VERTICAL HANGERS, DIAGONAL AND HORIZONTAL BRACES TO BE SIZED IN ACCORDANCE WITH SMACNA 6. NO TURNING VANES REQUIRED ON DUCT SIZES LESS THAN 180 SQ. IN.IF DUCT VELOCITY IS LESS THAN 1. SIZE REFRIGERANT PIPING PER MANUFACTURER'S RECOMMENDATIONS. hi 2. COORDINATE SPECIFIC DEVICES WITH MANUFACTURER'S RECOMMENDATIONS FOR EACH W SEISMIC RESTRAINT MANUAL. 1500 FPM. SYSTEM AND REFRIGERANT. (n J 7. COORDINATE WITH STRUCTURAL ENGINEER FOR UPPER ATTACHMENTS. 7. MAX. 4'FLEX ALLOWED ON HORIZONTAL CONNECTIONS. Z W m 00 0 (� ROUND DUCT SUPPORT d RETURN EXHAUST DUCT FITTINGS REFRIGERANT PIPING SCHEMATIC 0 Do SCALE; NONE r SCALE: NONE SCALE: NONE0 Q LL ~ � � SQUARE TO WW O ~ CONICAL OR LO-LOSS ROUND 45 TRANSITION LL DEGREE BOOT FITTING V 0- E W WITH VOLUME DAMPER U = W 0- 0 )Z-' TRANSITION Lb VD VD 15 DEGREE TYPICAL, `„ Q ROUND NEC 30 %_� W DIFFUSER DEGREE MAXIMUM SHEET METAL DUCT (TYP) O ROU D TYPICAL SQUARE NECK 12" "THICK DUCT LINER SHEET DIFFUSER. SIZE OF DUCT VD MINIMUM p METALFASTENERS OR GRIP NAILS TO LINER TO BE METAL DUCT 45 DEGREE DROP E MATCH DIFFUSER 12' N-- BE INSTALLED NOT ADHERED TO LO-LOSS NECK SIZE. VD VD AS REQUIRED INIMUM MORE THAN 2' DUCT BOOT x 20 GAUGE SHEET METAL HOOD FROM WITH 90 PERCENT TAP OR WITH 1-112"DUCT LINER INSIDE. O EDGE OF LINER. (MINIMUM) CONICAL TAP MIN 36" BEFORE 6' ADHESIVE COVERAGE AND AFTER MINIMUM SHEET METAL OR FLEX-TUBE U VD ELBOW TOP AND CENTERLINE RADIUS WATERTIGHT MECHANICAL DETAILS BOTTOM EQUALS 1.5 TIMES 7? SECTIONS OF REDUCER TO MATCH WIDTH fT �� LINER DIFFUSER SLOPE PIPES pJ SHALL OVERLAP NECK SIZE IF BRANCH DUCT IS AWAY FROM HOOD. PROJECT NO. \ THE SIDES OVERSIZED, LOCATE AT ROOFING BY 17055 CONNECTION TO DIFFUSER, ROOFING CONTRACTOR. 2, SPUTTER DAMPER WHERE SHOWN. DO 06.20.2019 3'CANT STRIP(MINIMUM) USE ON VAV SYSTEMS AIR FLOW IPI NG SIZE AS CUTAWAY VIEW DUCT SECTION INDICATED ON o PLANS t NOTES: 3 w 1. PROVIDE DUCT LINER AND10R EXTERNAL DUCT INSULATION AS NOTED ON PLANS OR IN SPECIFICATIONS. o 2. PROVIDE HANGERS AND SEISMIC BRACING PER SMACNA AND BUILDING CODE REQUIREMENTS. NOTES: 3. LOCATE MANUAL BALANCING DAMPERS IMMEDIATELY DOWNSTREAM OF EACH DUCT TAP. NOTES: 1. PROVIDE DUCT LINER AT LOCATIONS SHCWN ON DRAWINGS. 4. CUSHION HEADS OR BULLHEAD TEES ARE NOT ALLOWED. 1. REFER TO ARCHITECTURAL PLANS FOR ROOF CONSTRUCTION. 2. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 5, MAINTAIN MINIMUM 36"CLEARANCE BETWEEN LEADING OR TRAILING ELBOW JOINT AND DUCT TAP FITTINGS. 2. ALL EDGES SHALL BE ROLLED AND TURNED DOWN,SHARP EDGES WILL NOT BE ACCEPTED. 8 3. ALL ENDS OF LINER TO BE COATED WITH ADHESIVE.ENDS OF LINER SHALL BE BUTTED FIRMLY TOGETHER, 6. RADIUSED ELBOWS OR TURNING VANES REQUIRED ON RECTANGULAR DUCT SYSTEM ELBOWS. SINGLE 3. SEAL AS REQUIRED TO MAKE ALL JOINTS AND PENETRATIONS WATERTIGHT. H THICKNESS VANES UP TO 25' HEIGHT AND DOUBLE THICKNESS VANES IN DUCTS GREATER THAN 25" HEIGHT. 7. MAX. 4'FLEX ALLOWED ON HORIZONTAL CONNECTIONS, K DUCT LINER SUPPLY DUCT FITTINGS ROOF PIPE PENETRATION SCALE: NONE SCALE: NONE SCALE: NONE M901 n R c�ia 10373 r DIGITAL SIGNATURE ,f. OREGON q RENEWS: 06-30-2020 •,e SHEET METAL DUCT WITH 1.1 TANDING INTERNAL DUCT SEAM 8 4 TED OR INSULATION OR DOU BOLTED A RNERS WALL DUCT AT R �� -�"••�o-�»<< AND MAX 8" 0is „� g PENETRATIO ON FRED E.SRA ME. .a>+�sM.•” .FLASHINGROOF(TY �F --*•�� �_"--�d�=a -?°iLLtYH 9r11151.16E u ON OUS 114'X1' 1 CANT STRIPS, MIN 3" RENE GASKET (TYP) DUCT TOTAL HEIGHT(TYP) RE-FABRICATED STEEL PACK INSULATION CURB WITH WOOD NAILER, MIN 8'HIGH IN VOID SPACE 7 •° ° �P AROUND DUCT 114"LAG SCREWS AT 8' OPENING(TYP) OC(MIN 2 PER SIDE) 2 WOOD ROOF = OUNTER FLASHING ROOFING IEEK RATED WALL 5 =_ NOTES: ® I I. DAMPER BLADES FRT DF#1 LEVELING BLOCK 2, ELECTRIC ACTUATOR MOTOR INTERLOCKED WITH SMOKE DETECTOR OR FIRE ALARM SYSTEM.COORDINATE WITH SHAPED TO LEVEL CURB ILC M L ELECTRICAL DESIGN FOR POWER,CONTROL WIRING AND SEQUENCE OF OPERATION.ACTUATOR AND CONTROLS LOCATED 45 DEGREE IN SIDE PANEL(OUT OF AIRFLOW)AND ACCESSIBLE THROUGH REMOVAL GRILLE, 3, ELECTRIC RESETTABLE FUSIBLE LINK CLOSES AND LOCKS THE DAMPER WHEN TEMPERATURE EXCEEDS PRESET STEEL ANGLE IRON TEMPERATURE. DAMPER MAY BE RESET BY PRESSING RESET BUTTON. INTEGRAL DAMPER BLADE INDICATOR SWITCH FOR SUPPORT ON FOU DES SEGU UCT RISER TO REMOTE MONITORING OF OPEN AND CLOSED POSITIONS. OPENING E WITH 4. SLEEVE SECURED TO WALL WITH#10 LAG SCREWS AT 6" ON CENTER(MAXIMUM)ALL SIDES MAXIMUM OF T FROM CORNERS DUCT RISE TH INTERNAL NOT 114' EXHAUST PIPE AND MINIMUM OF 2 PER SIDE. FASTENING METHOD AS PERMITTED AS A CONDITION OF DAMPER LISTING. REFER TO INSULA , TRANSITION TO SHEET METAL SC S MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. EXT AL DUCT INSULATION USED (MIN 2 PER SIDE) 5. DAMPER SLEEVE ON OPPOSITE SIDE OF WALL FROM GRILLE MUST NOT EXCEED 16" LONG. OW THE ROOF EXTERIOR WALL 6. DUCT CONNECTION AS PERMITTED AS A CONDITION OF DAMPER LISTING.FLANGED BREAK-AWAY STYLE DUCTISLEEVE ATTACHANSEAL CONNECTIONS IZEDTORE WN. DUCT PENETRATION - WOOD ROOF SEAL AT WALL 7. WALL GRILLE. SIZED TO ALLOW ACCESS TO DAMPER ACTUATOR, FUSASLE LINK AND INDICATOR. 8. AREA SMOKE DETECTOR CONNECTED TO CENTRAL FIRE ALARM SYSTEM.SMOKE DETECTORS SHALL BE ADDRESSABLE AND SCALE:'NONE z UNIQUELY TAGGED. 9. FIREISMCKE DAMPER DETAIL FOR REFERENCE ONLY. FIRE DAMPER SHALL BE STATE FIRE MARSHAL APPROVED, INSTALL PER NOTES: MANUFACTURER' ('7 S PRINTED INSTALLATION INSTRUCTIONS WHICH SHALL BE MADE AVAILABLE TO INSPECTION AUTHORITIES, O 1. TERMINA"E DENT PIPE BEYOND BUILDING WALL WITH A 45 DEGREE ANGLE AND COVER WITH EXPANDED METAL SCREEN. 11, UL 555&5558 COMPLIANT. LISTINGS: RUSKIN#R5531,GREENHECK#R13317,POTTORFF#Ri 1767,NAILOR#R9492,CESCO#R6462 . _ 12. REFER TO SPECIFICATION SECTION 233113 FOR ADDITIONAL REQUIREMENTS. REFER TO N MXX BOILER FLUE - EXTERIOR WALL PENETRATION d FSD WALL GRILLE ACCESS ATTACHMENT ER R CTANG RECTANGULAR Z x m 6 SCALE: NONE T SCALE: NONE 0 0 1"X22 GA 2'-8'MAX TO Q STRAP STRUCTURAL LL (TYP) SU PP RT (D LL LuL- 5 4 Y )- Q SLEEVE W c� f - 1„ Lu L O 3 #10 SELF-TAPPING SHEET V U W METAL SCREWS,4 MINU = W W 1 COO DETAILA DUCT DUCT AIR FLOW (LESS THAN 6 SQUARE o 000 z FEET) (o C)" REFER 8 UPPER TO RECTANGULAR DUCT(TYP) W ATTACHMENT SEISMIC CABLE BRACE(TYP) c:) REFER TO THREADED ROD STRUCTURAL 2 3/8"DIA. ROD OR INSTALL AT EACH CORNER m SIZE TO SUPPORT LOAD DESIGN FOR UPPER 3"X3'X16 SUPPORT O z VIBRATION ISOLATION ATTACHMENT(TYP) GA ANGLE BOTH SIDES r- D HANGER, SWING SPRING 7 (TYP) 2 TYPE, 1" DEFLECTION(TYP) 6 RATED WALL #10 SELF-TAPPI NG SHEET 2 118'RESTRAINT METAL SCREWS,ONE MECHANICAL FORGED NOTES: ® g CABLE 105 8 PER WIRE ROPE CLIP. TO STRUCTURE(TYP) 1. DAMPER BLADES Q SIDE 45° U INSTALL TWO PER 45° 2, ELECTRIC ACTUATOR MOTOR INTERLOCKED WITH SMOKE DETECTOR OR FIRE ALARM SYSTEM. COORDINATE WITH ELECTRICAL CABLE END(TYP) DESIGN FOR POWER,CONTROL WIRING AND SEQUENCE OF OPERATION. THIMBLE(TYP) XCESS CABLE 3. ELECTRIC RESETTABLE FUSIBLE LINK CLOSES AND LOCKS THE DAMPER WHEN TEMPERATURE EXCEEDS PRESET TEMPERATURE. MECHANICAL DETAILS 1„ MIN 1' (TYP) DAMPER MAY BE RESET BY PRESSING RESET BUTTON.INTEGRAL DAMPER BLADE INDICATOR SWITCH FOR REMOTE MONITORING OF NUT WITH LOCK OPEN AND CLOSED POSITIONS. 318"DIA. BOLT, WASHER 12 4. STEEL RETAINING ANGLES, MINIMUM 1-112"x1-112"x0.060",FASTENED TO FIRE DAMPER SLEEVE. ANGLES SHALL BE INSTALLED ON ALL LOCK WASHER PROJECT ND. (TYP) FOUR SIDES OF DAMPER AND ON EACH SIDE OF THE WALL, FASTEN ANGLE TO SLEEVE WITH#10 SHEET METAL SCREWS(MINIMUM). & NUT. ANGLE GAGE AND FASTENING METHOD AS PERMITTED ASA CONDITION OF DAMPER LISTING. REFER TO MANUFACTURER'S WRITTEN 3"X3'Xi 6 GA 17055 FLOW —► EXHAUST FAN - INSTALLATION INSTRUCTIONS. MINIMUM 1"ANGLE OVERLAP ON ALL SIDES OF PARTITION WALL. TWO 318"DIA. LOCKNUTS (BACKDRAFT DAMPER 5. DAMPER SLEEVE ON OPPOSITE SIDE OF WALL FROM ACTUATOR MUST BE MINIMUM 3"AND MAXIMUM OF 6' LONG. LOCATED AT 6. DUCT CONNECTION AS PERMITTED AS A CONDITION OF DAMPER LISTING. FLANGED BREAK-AWAY STYLE DUCT/SLEEVE CONNECTIONS AND WASHERS ETAIL B 06.20.2019 BUILDING ARE SHOWN. (6 SQUARE FEET AND DUCT TRANSITION AS ENVELOPE 7. ACCESS DOOR SHOWN ON BOTTOM OF SLEEVE FOR ACCESS TO FIRE DAMPER BLADES.PANEL TO BE HINGED WITH AIRTIGHT SEAL. LARGER) REQUIRED TO MATCH FAN TERMINATION) ACCESS SIZE MUST BE MINIMUM OF 12'BY 12"OR THE WIDTH OF DUCT IF SMALLER THAN 12"WIDE, ACCESS PANEL MUST BE LABELED FLANGE SIZE(TYP) WITH THE WORDS, "FIRE DOOR-00 NOT OBSTRUCT"IN LETTERS NO LESS THAN V IN HEIGHT.EXTERNAL INSULATION SHALL NOT NOTES: o CONCEAL ACCESS UNLESS A LABEL IS ATTACHED TO THE INSULATION WHICH INDICATES THE EXACT LOCATION OF THE OPENING. 1. MAXIMUM SPACING OF HANGERS SHALL BE 6-0". �€ FLEXIBLE DUCT 8. DUCT SMOKE DETECTOR MOUNTED IN SLEEVE ON OPPOSITE SIDE FROM ACTUATOR WITHIN FIVE FEET OF DAMPER. OR,AREA SMOKE 2. SEISMIC RESTRAINT CABLES MAY BE OMITTED WHERE: CONNECTIONS AT DETECTORS CONNECTED TO CENTRAL FIRE ALARM SYSTEM. SMOKE DETECTORS SHALL BE ADDRESSABLE AND UNIQUELY TAGGED. A, RECTANGULAR DUCT IS LESS THAN 6 SQUARE FEET IN AREA OR DUCT OF ANY SIZE IS SUPPORTED WITHIN o INLET AND OUTLET 9. LOCATE 314'HIGH WHITE PLASTIC LAMINATE SIGNS WITH 318"HIGH BLACK LETTERING WITH THE INITIALS"FSD"AND UNIQUE NUMBER 12'OF STRUCTURE AS MEASURED FROM THE TOP OF DUCT TO THE BOTTOM OF STRUCTURE. & w ON THE CEILING ACCESS DOOR OR T-BAR CEILING GRID IN THE AREA OF THE DAMPER ACCESS PANEL.ATTACH TO CEILING WITH 3. WHERE SEISMIC RESTRAINTS ARE REQUIRED, NOTES: EPDXY ADHESIVE. A. PROVIDE TRANSVERSE BRACING AT 30 FT AND 8 1. PROVIDE BACKDRAFT DAMPER IN DUCTWCRK AT BUILDING ENVELOPE TERMINATION. 10, FIRElSMOKE DAMPER DETAIL FOR REFERENCE ONLY. FIRE DAMPER SHALL BE STATE FIRE MARSHAL APPROVED. INSTALL PER B. LONGITUDINAL BRACING AT 60 FT. w 2. TRANSITION DUCT CONNECTION AS REQUIRED TO MATCH FAN COLLARS. MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS. 4, VERTICAL HANGERS,DIAGONAL AND HORIZONTAL BRACES TO BE SIZED IN ACCORDANCE WITH SMACNA 3. REFER TO STRUCTURAL DESIGN FOR ATTACHMENT REQUIREMENTS AND ADDITIONAL SUPPORT 11. UL 555&5558 COMPLIANT. LISTINGS: RUSKIN#R5531, GREENHECK#R13317,POTTORFF#Ri 1767, NAILOR#R9492, CESCO#R6462, SEISMIC RESTRAINT MANUAL. L OPTIONS. 12, REFER TO SPECIFICATION SECTION 233113 FOR ADDITIONAL REQUIREMENTS, 5. COORDINATE WITH STRUCTURAL DESIGN FOR UPPER ATTACHMENT, EXHAUST FAN IN-LINE FSD WALL 3V BLADE RECT DUCT SUPPORT 5 SCALE: NONE SCALE: NONE SCALE: NONE a Q� M902 8w 0 0101373% EXHAUST ASSEMBLY DIGITAL. SIGNATURE ,JE OREGON q CONTINUOUS 114'X2" NEOPRENE GASKET RE-FABRICATED STEEL UC7, 30°X30" MAXIMUM (TYP) CURB WITH WOOD NAILER, (MAXIMUM) MIN 80 HIGH RENEWS; 06'30-2020 16 GAGE G SCREWS AT 8'OC ROUND, STAMPED,PLEATED,OR SHEET METAL RIGID ROUND SUPPORT DUCTING FROM GALVANIZED (MIN 2 PER SIDE) SEGMENTED SHEET METAL ELBOW. DUCT WITH 1'OF EXTERIOR STRUCTURE ABOVE BEAM'C"CLAMPS, SHEET METAL STRAP . EM1ME"WlEE SE MIN. 0.6 RID RADIUS ELBOW WRAPPED INSULATION. DUCT LASHING FRED E.SHMIBE,F _u K�x'f'"' TYPICAL --- AllSIZE AS NOTED PER PLAN ! ROUND -- - — — MAIN ROOFING DUCT VERTICAL CANT STRIP,MIN TRUSS 3'HIGH (TYP) AIR FLOW MEMBER I I / I II II I i II II I [ II II I NEW DUCT HEIGHT BALANCE DAMPERS(TYPICAL) 1 II 11 I � DEPENDS ON EXISTING UPSTREAM OF CEILING WOOD ROOF DUCT ELEVATION SUPPLY DIFFUSERSkj I II I I FRT DF#1 LEVELING DUCT RISER WITH 0.5" I II I I i BLOCK EXTERNAL INSULATION SHAPED TO LEVEL CURB 12"MIN. NO FLEX DUCT 10'FROM DISCHARGE LLC ALLOWED NOTES. 1, COORDINATE ROOF OPENING, BLOCKING,CURBING,CANT STRIPS &FLASHING WITH ROOFING INSTALLER, ROOF PENETRATIONS SHALL NOT VOID ROOF WARRANTY. CEILING DIFFUSER- SUSPENDED CEILING 2. PROVIDE PACKING AND SEALING MATERIALS AS REQUIRED BY ROOF RATING. NECK SIZE,AND CFM 3. ALL SIZING, LOCATION,AND ANCHORING SHALL BE COORDINATED WITH STRUCTURAL DESIGN. PER PLANS NOTES: LOUVERED PENTHOUSE - WOOD ROOF 1. REFER TO PLANS FOR SIZES AND CONTINUATION, SCALE: NONE ROUND SUPPLY DIFFUSER-CEILING RECT DUCT VERTICAL SUPPORT P#10 SM ER BRACKEW' TWO z 7 SCALE:NONE SCALE: NONE UNIT SECURED TO D PLATFORM WITH 1!4'X3' UNIT M 0 LAG SCREWS N Z 474"X118"ANGLE 18'PLYWOOD I-- W TWO PER SIDE WITH 8d AT 6'OC (n M —J 24 GAGE GALVANIZED EDGE NAILING Z LL m SHEET METAL 0 Q FLASHING [] CAP. NAILTOCURB 0 314"X2"NEOPRENE CANT STRIP 0 (D L1_. W GASKET EYE BOLT,WELDED co UNIT FINISHED ROOF LJ.1 O H CLOSED ACK DRAFT DAMPER AIRCRAFT SECURE DUCT TO � 1'1' CABLE ROOF CURB WITH LAG V Y U) ll� RYER BOOSTER FAN CABLE CLAMPS SCREWS AT 12'OC Y Q- CC (MIN 2 PER END) (MAX) 0 � z CEILING—/ HEX HEAD LAG BOLT WI MIN 1-1(2" w (p f)� PENETRATION INTO 2"X4'WOOD NAILER WOOD ROOF AT EACH CORNER(TYP OF 4) 4"XB"(MIN) FIRE RETARDANT ❑ � Q SECURE NAILER TO TREATED(FRT)WOOD FRAME Lu U) 0- CURB WITH LAG ALL AROUND.PROVIDE 22 GAUGE COUNTERINTERMEDIATE SUPPORT AT O FLASHING SCREWS AT 12" OC 48" OC AS REQUIRED. Q EYE BOLT, WELDED r CLOSED NOTES: c- ACCESS DOOR STEEL WASHER 1. COORDINATE ANCHORAGE REQUIREMENTS WITH STRUCTURAL DESIGN, WALL INSULATION CONDENSING UNIT-ROOF MOUNTED 0 LINT TRAP(IF REQUIRED BY BOOSTER FAN MANUFACTURER) CANT STRIP 16 GAUGE(MAX) 2 0 METAL CURB BOOSTER FAN WALL INDICATOR PANEL SCALE:NONE 4" DIA. GALVANIZED SHEET METAL DUCT ROOFING ADJUST THROW OF VERTICAL %22�6 JUST THROW OF DUCT BLADES FOR 113 OF AIR RIZONTAL MECHANICAL DETAILS STRAIGHT AND 113 OF AIR TO DES FOR 112 OF AIR 45 AIGHT AND W OF AIR TO _ DEGREES RIGHT AND 1/3 OF PROJECT NO. RYER 45 DEGREES LEFT. GREES DOWN. 17055 j ADJUSTABLE / STAINLESS WOOD ROOF 06.20.2019 STEEL DRAW BAND SUPPLY DUCT NOTES: 5 NOTE: 1. SEISMIC RESTRAINT ASSEMBLY SHALL BE INSTALLED DIAGONAL AT EACH CORNER FOR SMALL UNITS OR ON \ ~ 4 1, REFER TO PLANS FOR SIZES AND CONTINUATION, ALL SIDES OF LARGE UNIT,THREE ASSEMBLIES AT LONG SIDES AND ONE AT SHORT SIDE. 12' 2. SUPPORT DUCT AT C INTERVALS PER CODE 2. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL, MIN DUCT & 3. METAL DUCT REQUIRED WITH SMOOTH INTERIOR FINISH &BY 0.0161THICK MIN. 3, COORDINATE ANCHORAGE REQUIREMENTS WITH STRUCTURAL DESIGN. MAINTAIN MOUNTED 4. BOOSTER FAN NOT REQUIRED IF EXHAUST RUN CONFORMS TO DRYER MANUFACTURER 4. ROOF-TOP EQUIPMENT SHALL BE INSTALLED ON THE ROOF IN A LOCATION WITH ADEQUATE STRUCTURAL SUPPLY ° INSTALLATION REQUIREMENTS. STRENGTH TO SAFELY SUPPORT THE ENTIRE WEIGHT OF EQUIPMENT AND SERVICE PERSONNEL.CARE MUST MINIMUM FIMUM 10 aWfiS E DAMPER S 5, BOOSTER FAN OPERATES BASED ON PRESSURE IN DUCT OR PER CURRENT SENSOR AS BE TAKEN NOT TO DAMAGE THE ROOF,COORDINATE WITH STRUCTURAL ENGINEER. w DETERMINED BY BOOSTER FAN MANUFACTURER, 6. IF BOLTED CONSTRUCTION IS NOT A VIABLE OPTION, PROVIDE WELDED CONNECTION PLATE, w NOTES: '- 1. ADJUST INITIAL AIR FLOW DIRECTIONS AS SHOWN.FINAL AIR BALANCE SHALL ADJUST FLOW DIRECTIONS TO REDUCE AIR VELOCITIES IN OCCUPIED SPACE TO 50 FPM(MAXIMUM). z IN LINE - DRYER BOOSTER CURB DETAIL-WOOD SEISMIC EXPOSED DUCT SUPPLY REGISTER 6 SCALE: NONE SCALE: NONE SCALE:NONE o M903 a� gn el;013N%73 DIGITAL SIGNATURE ,j. OREGON A 1 RENEWS: 06-30-2020 EXTERIOR WALL LOUVER EITHER TO rxdn"�""y REFERENCE ARCHITECTURAL RISER OR o," �..w"a.. — TO ROOF, vvpp � �GES'o� (SEE PLANS) EXTERIOR LOUVER REFERENCE RISER Ms.oz FREb E.SRAUB AqE tl' a �,y SEE FLOOR PLANS DIAGRAM 1A ~' �•«"•"«w A 3 3 ON RATED SOFFIT PIPE INSULATION AND JACKET U-CLAMP, 118"STEEL, 1-518' RATED WOOD ASSEMBLY (WHERE APPLICABLE} WIDE. 2 PIPE SHEET METAL EXHAUST <A- _ _ _ _ <'r � DUCT AND TRANSITION E 0iB GYP CEILING BACK DRAFT DAMPER INTEGRAL A PIPE SADDLE ■1►. Vti TRANSITION AS REQUIRED TO HOOD Ms.oz PRE-ASSEMBLED STAINLESS PLENUM SECTION A-A STEEL THREADED SUPPORT RODS AND CHANNEL STRUT. «� DETAIL NOTES: 1. WALL ASSEMBLY:THE 1 OR 2 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U40D SERIES WALL NOTES: �J OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: SET IN BED OF MASTIC,VERIFY 1. DOMESTIC KITCHEN SYSTEMS A. STUDS-WALL FRAMING SHALL CONSIST OF METAL STUDS TO BE MINIMUM 3-112"WIDE AND SPACED TO MASTIC TYPE WITH ROOF SHALL BE EQUIPPED WITH A HIGH/MEDIUM/LOW, CONTROL BY OTHERS 24 OC. MEMBRANE MANUFACTURER BACKDRAFT DAMPER IMC 2012 B. GYPSUM BOARD-TWO LAYERS OF NOMINAL 518" THICK GYPSUM WALLBOARD AS SPECIFIED IN THE AND GENERAL CONTRACTOR. 505.1 RANGE HOOD WITH INDIVIDUAL WALL AND PARTITION DESIGN. MAXIMUM DIAMETER OF OPENING IS 17-1J2'. 2. DUCTWORK SHALL DISCHARGE INTEGRAL FAN&CONTROLS, ALL NOTES: DIRECTLY TO OUTDOORS IMC 2012 BY OTHERS 2. THROUGH PENETRANT:ONE STEEL DUCT TO BE INSTALLED EITHER CONCENTRICALLY ECCENTRICALLY 1SUPPORT PIPE EVERY 6'OC (MAXIMUM)AND AT EACH ELBOW. 505.1 WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN DUCT AND OPENING SHALL BE MIN OF Q ,O Z z 3. SYSTEMS SHALL ROUTE MAXIMUM OF 1-112 STEEL DUCT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY.THE {n INDEPENDANT OF OTHER 000 OOO FOLLOWING DUCES OF STEEL DUCTS MAY BE USED: A. STEEL DUCT: NOMINAL 16' DIAMETER OR SMALLER, 24 GAUGE OR HEAVIER, SPIRAL WOUND EXHAUST SYSTEMS IMC 2012 505.1 0 o 0 GALVANIZED STEEL DUCT. N = 4. MAKEUP AIR SHALL BE PROVIDED B. STEEL DUCT: NOMINAL i0' DIAMETER OR SMALLER,28 GAUGE OR HEAVIER,GALVANIZED STEEL VENT N FOR HOODS EXHAUSTING Lam- (JJ GREATER THAN 400 CFM IMC 2012 DUCT, 67 _J 3. FILL, VOID OR CAVITY MATERIAL-CAULK OR SEALANT:MINIMUM 1-i14' THICKNESS OF CAULK MATERIAL � 505.2 APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY,AT THE POINT CONTACT PIPE STAND z XM LOCATION BETWEEN DUCT AND WALLBOARD,A MINIMUM 114' DIAMETER BEAD OF CAULK SHALL BE APPLIED 2 SCALE: NONE 0 AT THE WALLBOARD/DUCT INTERFACE ON BOTH SURFACES OF THE WALL ASSEMBLY.THE HOURLY F RATING AND T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL 0 ASSEMBLY IN WHICH IT IS INSTALLED AS TESTED AND LISTED BY PRODUCT MANUFACTURER. LL Oo (D Q W DOMESTIC KITCHEN EXHAUST ROUND DUCT PENETRATION FRAMED WALL 2 Hr Y F 6 SCALE: NONE SCALE: NONE w O F- LL D_ 0 W REFER TO STRUCTURAL DETAIL fA Y a FOR UPPER ATTACHMENT(TYP) im A 3 O H Z 3 ( }— VIBRATION ISOLATORS SPRING < — AND DOUBLE DEFLECTION 2 W (0 UNIT SUPPORT, 318" NEOPRENE HANGERS. MASON CEILINGISTRUCTURE TYPE 930N.(TYP) THREADED ROD(TYP) 0 } �POWER(DIV.26) AIR FILTER BANK OR p z VERIFY FAN EXTENSION INTERNAL TO UNIT r LENGTH PRIOR TOCRDER �� COOLINGCOIL Tl_ D AND INSTALLATIONA Jf 16 2 REFRIGERANT PIPING O U SECTION A-A SUPPLY AIR NOTES: RETURN AIR 1. WALL ASSEMBLY: THE i OR 2 HOUR FIRE-RATED GYPSUM WALLBOARDISTUD WALL ASSEMBLY SHALL BE MECHANICAL DETAILS FLEXIBLE DUCT CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES CONNECTION XCESS CABLE WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING (TYP OF 2) MIN V (TYP) CONSTRUCTION FEATURES: TEMPERATURE/HUMIDITY/OCCUPANCY PROJECT NO. SENSORS INTEGRAL TO FAN 118"WIRE ROPE(TYP A, STUDS-WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS(MAX 2 HR FIRE RATED ASSEMBLIES)OR 17055 AT 4 CORNERS) STEEL CHANNEL STUDS. B. GYPSUM BOARD-NOMINAL 518"THICK.THE GYPSUM WALLBOARD TYPE,THICKNESS, NUMBER OF LAYERS, PRIMARY COOLING COIL ROSBY FORGED WIRE ROPE FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 CONDENSATE DRAIN PIPE. CLIP. INSTALL TWO PER CABLE SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. 06.20.2019 COORDINATE MOUNTING HEIGHT SEE FLOOR PLANS FOR END PER MANUFACTURER'S 2. THROUGH PENETRANT: ONE METALLIC PIPE OR TUBE INSTALLED EITHER CONCENTRICALLY OR WITH ARCHITECT ROUTING INSTRUCTIONS(TYP) ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM.THE ANNULAR SPACE BETWEEN PIPE,CONDUIT OR TUBING v(TYP) AND PERIPHERY OF OPENING SHALL BE MIN OF OTO 2".PIPE OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH S SIDES OF WALL ASSEMBLY.THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR TUBING MAY BE USED: S 112"(n'P) A. STEEL PIPE: MAXIMUM 12" DIAMETER STEEL PIPE. THIMBLE(TYP) B. IRON PIPE:MAXIMUM 12" CAST IRON OR DUCTILE IRON PIPE. WIRELESS WALL C. COPPER TUBING: MAXIMUM 6" TYPE L OR HEAVIER COPPER TUBING OR COPPER PIPE. g' CONTROLLER-ON/OFF, 42-4 D. FLEXIBLE METAL PIPING: MAXIMUM 2' DIAMETER AS ALLOWED BY UL LISTING. w SPEED, W FAN COIL UNIT EILING (TYP) 3. FILL,VOID OR CAVITY MATERIAL-CAULK OR SEALANT: MINIMUM 518"OR 5/8"THICKNESS OF CAULK FOR 1 AND 2 5 FORWARD/BACKWARDS AFF HOUR RATED ASSEMBLIES, RESPECTIVELY,APPLIED WITHIN ANNULUS,FLUSH WITH BOTH SURFACES OF WALL. o NOTES: DIAMETER BEAD OF CAULK APPLIED TO GYPSUM BOARDIPENETRANT INTERFACE AT POINT i. REFER TO PLANS FOR SIZES AND CONTINUATION. MINIMUM 114 CONTACT LOCATION ON BOTH SIDES OF WALL. THE HOURLY F RATING AND T RATING OF THE FIRESTOP FLOOR 2. PROVIDE HIGH FLOAT SENSOR W/ALARM TO SHUT DOWN UNIT IN EVENT OF PRIMARY CONDENSATE BLOCKAGE SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED AS 5 TESTED AND LISTED BY PRODUCT MANUFACTURER. T=O HOUR FOR PIPE DIAMETER GREATER THAN 1". 3. ACOUSTICALLY LINE SUPPLY AND RETURN DUCTS WITH 1' LINER 5UPSTREAM/DOWNSTREAM OF FCU. 4. 3M SYSTEM#W-L-1001. a 5 CEILING FAN DETAIL 3 FAN COIL - SUSPENDED 1 PIPE PENETRATION FRAMED WALL 1 OR 2 HR SCALE; NONESCALE: NONE SCALE: NONE M904 z a� c4 a �������D spN�����fad � 10373 r DIGITAL SIGNATURE Ew RENEWS: 06-30-2020 SHEET METAL TED WOOD ASSEMBLY DUCTWORK ROUTES TO SUB-DUCT- :RyS3- SEE ENLARGE PLANS ��;tlixrnw8uw,a M vF FREVE.SHAUE, M1�f c�- Ecluw.>¢v �`,.ab,bpn y_, n..m.G�a,.uraa.ae SHEET METAL BOX BIRD SCREEN ON-RATED INTEGRAL OBD SOFFIT LOUVER GYPCEIUNG CEILING I l L E K. WATER STOP EXHAUST GRILLE „„%^:, 2x4 WOOD BLOCKING uc WALL ASSEMBLY PER ARCHITECTURAL NOTES: i. SEE FLOOR PLANS FOR ADDITIONAL INFORMATION 2. OCC SENSOR INTEGRAL TO UNIT. TO RUN 20 MIN AT PEAK AIRFLOW. NORMAL OPERATION IS LOW AIRFLOW. EXTERIOR WALL LOUVER } UNIT TOILET/KITCHEN EXHAUST GRILLE 5 SCALE: NONE SCALE: NONE 0 Z W D M Q N = SHEET METAL PLENUM WIT THICK W RIGID INSULATION(WIVAPOR BARRIER) U1 O 1 co EXTERIOR WALL NOTE 1 O O Q (REFER TO ARCH TOILET EXHAUST D DRAWINGS) DUCTS(WRAPPED IN INSULATION) 2 NOTE 2 0 < ~ � VW W i-~ � U)*Ar �r W �— O LL FIRE PARTITION V Y U LOUVER(REFER TO ARCH DRAWINGS). KITCHEN EXHAUST � Y 0' � � DUCTS(WRAPPED IN INSULATION) 0 Z W FIRE CAULK NOTE 2 0 2 AT OPENING 00 1-112"x1-112"x0.060' W RETAINING ANGLES, BOTH ❑ SIDES. SECURE TO WALL PLAN VIEW � Uj CL WITH MIN. #10 SCREWS O O O U SHEET METAL PLENUM WIT THICK LOUVER(REFER TO RIGID INSULATION(WNAPOR ARCH DRAWINGS) BARRIER) MECHANICAL DETAILS NO BIRD SCREEN DUE TO DRYER. I r DUCT PASSING THRU E v— PROJECT NO. DEMISING WALL(ROUND / OR RECTANGULAR) 17055 MINERAL WOOL IN GAP 6"MIN. EXTERNALLY INSULATE RESIDENTIAL CORRIDOR- -APARTMENT- BETWEEN SLEEVE AND EXHAUST DUCTS-10'FROM EXTERIOR WALL OPENING 06.20.2019 EXTERIOR WALL CAULK/SEAL PENETRATION(S) 12"L WALL SLEEVE AIR-TIGHT MIN.0.060"THICKNESS ELEVATIOt�I 0 NOTES: NOTES: a DUCT PENETRATION TO BE IN ACCORDANCE WITH IBC 716.5.4 EXCEPTION#3: 1. WIDTH/DIMENSIONS OF PLENUM FIELD DIMENSIONED 70 SUIT DUCTWORK SIZE. S 3.1 DUCT NOT TO EXCEED 100 s0. IN. '2. INSULATE DUCTWORK BACK 10FROM EXTERIOR-SEE SPECIFICATIONS 3.2 DUCT TO BE STEEL, NOT LESS THAN 24 GAGE THICKNESS � 3.3 DUCT NOT TO SHARE OPENINGS WITH CORRIDOR 3. DISCHARGE LOCATION SHALL BEAT LEAST T FROM OPERABLE OPENINGS INTO BUILDING 3.4 DUCT TO BE ABOVE CEILING 4. DISCHARGE LOCATION SHALL BE AT LEAST 10'FROM MECHANICAL INTAKES c 3.5 DUCT NOT TO TERMINATE AT RATED GRILLE 5. KITCHEN BACK DRAFT DAMPER SHALL BE AT HOOD LOCATION WITH ACCESS 3.6 DUCT SLEEVE TO BE 12"Lx0.06 THICK WITH MINERAL IN ANNULAR SPACE 6. TOILET BACK DRAFT DAMPER SHALL BE LOCATED INTEGRAL TO FAN DUCT PENETRATION SIDEWALL DISCHARGE - KITCHEN AND TOILET 3 SCALE: NONE � SCALE:NONE M905 8w