Loading...
Plans (37) BUP2021 -00190 OFFICE COPY RECEIVED JUL 2 7 2021 CITY OF T IGARD DrSNIP BUILDING DIVISION N O W N >m h W O) TENENT IMPROVEMENT > m N � ao M 6 N PERMIT SETE ^ O r NORTH S ITE P LAN (D 1/16' V-0" SUMMARY OF WORK SHEET INDEX PROJECT TEAM E U THE WORK CONSISTS OF ALTERATIONS TO ARCHITECTURAL OWNER V) ° EXISTING 1 ,134 SF TENENT SUITE ON FIRST G1 .1 COVER / SITE PLAN James Randall S FLOOR. G1 .2 CODE SHEET MedZec E E 12511 SW 68th Ave. se p WORK TO INCLUDE INTERIOR PARTITIONS, A1 .1 DEMOLITION PLANS Portland OR 97223 DOORS, CEILING TILE AND SOFFITS, A2.1 FLOOR PLAN/REFLECTED CEILING PLAN Z CASEWORK, FINISHES, HVAC, PLUMBING, AND ELECTRICAL. A3.1 ELEVATIONS W PROPERTY LINE — SITE ENTRANCE PROJECT MANAGER w - - - - - - - - - - - - - - - - - - - - - - - - - - - — - - A4.1 DETAILS / DOORS EXISTING VAN ACCESSIBLE grayscale works Q �; p PARKING STALL - WALK AND CONTACT: MATHIEU JACOBS � W PAVING AT SAME GRADE 3045 NE 34TH AVE PORTLAND, OR 97212 LU DEFERRED SUBMITTALS 503-575-5141 QFMECHANICAL mjacobs@grayscaleworks.com = Q ELECTRICAL ARCHITECT EXITING PARKING LOT PLUMBING = kim s. mullen, architect 12425 NE Beech St a ® 00 Portland, OR 97230 V 3 GENERAL CONTRACTOR -f— CY) NORWEST CONTRACTORS N cn m 4820 SW SCHOLLS FERRY RD 0- PORTLAND, OR 97225 0:� 503-292-6266 0 CONTACT: GEORGE SCHRADER ® TENANT Q O } DrSnip m CONTACT: Trevor Kurtz ® iiEii trevor@drsnip.com L Q Q 00 NORTH SW BEVELAN D ST VICINITY MAP NOT TO SCALE 3 V) r 1-5 N H 217 99-W SITE • 12511 SW 68th AVE DRAWN: ksm PORTLAND OR 97223 CHECKED: MJ OFFICE COPY CITY OF TIGAM,• DATE: KRUSE WAYFOR CODECOMPLTANCX REVIEW SET 30 JUN 2021 App 'IjI REVIEW SET 8 JUL 2021 99-W OTCs t ] Permit Qom.. PERMIT SET 8 JUL 2021 NAddmat ' 1 . C.9.�.�.� 1-5 Suite ►aim Bn Dam PERMIT SET COVER / SITE PLAN VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER • DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM G1 REQUIRING THE CORRECTION OF ERRORS.OSSC 105.4 EXIT B 32" width ® 0 3 m N ■ I U � n v ■ i ■ i I OFFICE g i ■ —• ® ' RECEPTION 104 ■ 22 E— 103 WAITING ■ 101 ■ �wi. I ■ • : I I o WAITING ■ �- I i 179 7n N 10 E PATIENT 1 vi } I 25.5 1 % ■ ■ ■ ■ ■ ■ ` 105 � ■ f— v I ■ ■ \ �<94 ST OR. � LU z ll 1 3'-4 1/2"7PATIENT 2 106 0 C p SECURITY DOOR OPERATION: 0 (EFFECTING FIRE LIFE SAFETY) EXIT A 64" width -� O DOOR HAS PANIC BAR FOR FREE EGRESS AT ■ ALL TIMES. LAB ■ ■ 110 ■ O DOOR HAS LEVER LOCKSET HARDWARE - o -� ■ ENTRY FUNCTION. ALWAYS FREE FOR EGRESS. ■ I . I HALL PATIENT 3 0 LU -� 109 107 � � ® I N FIRE AND LIFE SAFETY ANALYSIS --- S o� Building Code: 2019 OSSC (for all new work) L__1 _ -iL_--___I' O Building Occupancy: B - professional services ♦� 96 15n 6.4 1 Building Construction Type: V-B BREAK O O Fire Protection: Not Sprinklered 108 • — Building Exit Travel Distance: May not exceed 200 ft (table 1017.2) - ♦1 L N for more than 1 exit > Q Q Building Area / Stories 7,738 SF / 2 stories co Suite Area: 1 ,134 SF �O Occupant Load: See chart = 38.7 occupants N Required # of exits: 1 Spaces with One exit (Table 1006.2.1 ) n 1 LO Common path of egress: 75 feet max. NORTH VJ CV EGRESS PLAN Accessible Barrier Removal: OSSC Chapter 11 All new work will comply with Chapter 1 1 �7 /4" _ '-Q" 0 2' a� a' and ICC Al 17.1 . to include: SCALE: 1/4"= 1'-0" - Door clearances CONSTRUCTION LEGEND - Transaction and Break room Counter (print on 24x36) 0 EXISTING WALL TO REMAIN heights - Reach ranges to outlets, switches, FEC, DRAWN: ksm door hardware. TO� NEW WALL DE OF CEILING. �5 CHECKED: MJ OCCUPANT LOAD O ALL WALLS, UNLESS NOTED A4.1 DATE: OTHERWISE Room Area Function Load Factor Occupants # Exits Req'd SOUN5 REVIEW SET 30 JUN 2021 COMMON PATH OF EGRESS < 75 FT Waiting 179 7 net 25.5 1 Assembly � OF CEIDLINGLL TO UNDERSIDE A4.1 REVIEW SET 8 JUL 2021 ■ ■ ■ ■ ■ ■ ■ ■ Concentrated PROVIDE BID ALTERNATE Concentrated PERMIT SET 8 JUL 2021 © EMERGENCY EGRESS LIGHT Reception 102 actual 2 1 PRICE TO EXTEND WALLS TO A4.1 Business 6" ABOVE CEILING AND ILLUMINATED EXIT SIGN Treatment OVERLAY TOP OF WALL (3 rooms) 112-132 Outpatient areas 100 gross 3.6 1 ea WITH 48" WIDTH 3-1/2" ROCK WOOL INSULATION Office 70 Business 150 gross 0.5 1 ea PERMIT SET ROOM AREA (SF) io ioo OCCUPANT LOAD FACTOR Break 96 Business 15 net 6.4 1 ea EXISTING 2x6 FRAMED CODE 2 (g=gross, n=net) Lab 67 Business 100 gross 0.7 1 BEARING WALL TO REMAIN # OF OCCUPANTS REQUIRED # OF EXITS Total Suite 38.7 1 o EXISTING 1 HOUR RATED CORRIDOR WALL Occupants � NEW 1 HOUR RATED WALL UNDER STAIRS REMOVE EXISTING WALL ■ ^+ m N W m r � m ® ® ® ® U a U) m a ,n ICU c c r T ui r I I I I ZE I XE I OXE I I ,r _ I 1 I I I II I I i • I 1 � I I ' I II I I ii I I I 1 I 11 1 1 I J I I I I 1 11 1 1 O II I I I I I 1 I I ZE I V) It � � � �i DEI�10 i D MOi 1 I r� N � XE i i� D Mo ) ZE • I i' I I I ^^ 1 1 1 I U E � EM I I I FTI O I I I I I I I I I I II 1 __ L___J L___J L___J o • 1Lll • � I I I I I 1 I I • ' ' ,(� I I I I X • 1 ` I AA1 ' 1 �� Y�Z ! i i DI 1 1 _ 1 i 1 vY i 'L MO w O r-� 1 Q I Q uj I I I I 11O � D�M I n 2 O. I I J E Li I ---------------1 i DEM ' 1 — u I I 1 II IIOI I I I I n 11 II WI I I II II QII ----- -_- I I ________________________ I l u' I I 'r c 11A CEILING FIXTURE LEGEND ' 1 \ r 'k-1 O i w XE CONSTRUCTION LEGEND 4- -, , , a EXISTING WALL TO REMAIN N EXISTING 2'X4RECESSED TROFFER 1101 I 1 `` N LIGHT FIXTURE TO BE RETROFITTED. oNE i i i NEW WALL W uwQ I 1 1 TO UNDERSIDE OF CEILING. l� ; ; � O EXISTING 2'X4' RECESSED TROFFER ii i i O ALL WALLS, UNLESS NOTED A4.1 LIGHT FIXTURE TO BE REMOVED AND ' ' OTHERWISE nl RELOCATED IN NEW PLAN VJ SOUND WALL TO UNDERSIDE PENDANT FIXTURE WITH DOWN AND UP w OF CEILING LIGHT. 24" DIA & 18" DIA. SEE PLAN © PROVIDE BID ALTERNATE 4 O O I E PRICE TO EXTEND WALLS TO A4.1 ' n- �� 6" ABOVE CEILING AND �°o\ OVERLAY TOP OF WALL Q RECESSED DOWNLIGHT y WITH 48" WIDTH 3-1/2" ROCK Q > WOOL INSULATION SURFACE MOUNTED WALL WASHER00 EXISTING 2x6 FRAMED 0O 0 BEARING WALL TO REMAIN UNDERCABINET LED LIGHT. SEE PLAN FOR LENGTH o EXISTING 1 HOUR RATED CORRIDOR WALL N �� NEW 1 HOUR RATED WALL UNDER STAIRS 0 24" STRIP LIGHT ABOVE CLOSET DOOR �� LO N HEAD ---------� REMOVE EXISTING WALL NORTH NORTH ILLUMINATED EXIT SIGN REFLECTED CEILING DEMO PLAN ELECTRICAL LEGENDDEMOLITION PLAN (E=EXISTING, W= SIDE WALL MOUNTED 2 `— JUST BELOW ADJACENT SOFFIT ) q 1 /4" = 1 '-0" New Exit. A 1 /411 = 1_ 0 2' 4' 8' 0 2' 4' 8' EMERGENCY LIGHTSWALL RECEPTACLE DUPLEX SCALE: 1/4"= 1'-0" SCALE: 114"= 1'-0" (print on 2436) WALL RECEPTACLE FOURPLEX (print on 2436) CEILING HT ABOVE FINISH FLOOR WALL RECEPTACLE VOICE/DATA DRAWN: ksm 10'-0" UNLESS NOTED OTHERWISE CEILING PLAN NOTES JUNCTION BOX PLAN NOTES O CHECKED: MJ 1 . EXISTING 2' x 4' CEILING GRID TO REMAIN \' ``rn, I REMOVE EXISTING OUTLETS DATE: HVAC SUPPLY AND RETURN GRILLES THROUGHOUT AS SHOWN ON PLAN. SHOWN FOR REFERENCE 1 . REMOVE EXISTING FEC AND SALVAGE FOR RELOCATION IN REVIEW SET 30 JUN 2021 PROVIDE SUPPLY AND RETURN IN EACH NEW PLAN. OCCUPIED ROOM. PROVIDE ZONE HEIGHT OF OUTLET FROM TO REVIEW SET 8 JUL 2021 PLAN FOR APPROVAL +46" CENTERLINE OF OUTLET. HEIGHT TO BE 2, REMOVE EXISTING SINK AND CAP PLUMBING IN WALL OR 18" UNLESS NOTED OTHERWISE. PERMIT SET 8 JUL 2021 FLOOR. LIGHT SWITCH VERIFY SWITCHING WITH TENANT ON SITE. E EXISTING TO REMAIN PERMIT SET DEMO REMOVE EXISTING FIXTURE. DEMO PLANS SALVAGE AS REQUIRED A1 . 1 9'-0" y 3 " m N Align soffit with cll m window head ® ® on U 'a a a Lq OFFIC B ALIGN oQ o E O'<. [T<E 1041 E I I C B --- — A = - k I I I I g' M OFFICE z A3.1 O J10 0 _ RECEPTION 30'± REOEPTIO r 141 \ I 101 . 1 ' 0„ 04 103 104 j103 ___ E I -- 1 ,9 ; 0 3'-0"� 104 N (TING N I c WAITING v I o - 101 10 0 TIENT 1 101 1 48 x 6o B +- i 105 I ------- O B NU. SE 0 } E 30" E I 4'-4" z A 102 0 s 105 105 � U \ NURSE 2 PATIENT 1 L. I 102 30B° E o I I --- 48 x 52=Q A3.1 105 J ' — — I C� --------------- uu O 'L L B O LOPED � 0 z 8'-0. I I s S 111 � PATIENT 2 z < f� S E 0 106 A - a 106 HAL. TIENT C F 4 LAB 106 42 x 58 110 4 ----- - Lu 10 41 B A3.1 1 CEILING FIXTURE LEGEND A LAB 1 '-o" 7100° CONSTRUCTION LEGEND 110 B RETROFITTED 2'X4' RECESSED TROFFER E a EXISTING WALL TO REMAIN ; \\ 1 s 1 B 0 �— (7 LIGHT FIXTURE (SEE DEMO PLAN FOR - 04 RELOCTION). RETORFIT TO LED AVANTE 107 PA IENT3 NEW WALL z HAL 107 PATIENT 0 ^�^`` C'%,4 OR EQUAL 3 10-0 18' 107 O TO UNDERSIDE OF CEILING. 1 a- 109 i 107 W O. ' ' 42 x 58 ALL WALLS, UNLESS NOTED A4.1 L-------- B PENDANT FIXTURE WITH DOWN AND UP -- - -- OTHERWISE n` LIGHT. 24 DIA & 18" DIA. SEE PLAN W SOUND WALL TO UNDERSIDE co 48" ® OF CEILING A4.1 0 ' \ Q RECESSED DOWNLIGHT 10 0 © PROVIDE BID ALTERNATE r4 +0 i_L O PRICE TO EXTEND WALLS TO A4.1 48x60 ! ° B z E 6" ABOVE CEILING AND ----________� 3 3 SURFACE MOUNTED WALL WASHER OVERLAY TOP OF WALL BR (/� A3.1 WITH 48" WIDTH 3-1 /2" ROCK 108 Qj > D UNDERCABINET LED LIGHT. BREAK WOOL INSULATION Q Q SEE PLAN FOR LENGTH 108 EXISTING 2x6 FRAMED 00 00 0 24" STRIP LIGHT ABOVE CLOSET DOOR BEARING WALL TO REMAIN 1-0 HEAD o EXISTING 1 HOUR RATED CORRIDOR WALL N NEW 1 HOUR RATED WALL UNDER STAIRS '— ILLUMINATED EXIT SIGN /�� /�� l- (E=EXISTING, W= SIDE WALL MOUNTED REMOVE EXISTING WALL QJ N `— JUST BELOW ADJACENT SOFFIT ) NORTH NORTH EMERGENCY LIGHTS REFLECTED CEILING PLAN ELECTRICAL LEGEND 2 FLOOR PLAN A2. 1 /4 , _ 1 '-o" 0 2' 4' 8 New Exist. A2. 1 /4„ _ -o" 0 2 `I 8' CEILING HT ABOVE FINISH FLOOR WALL RECEPTACLE DUPLEX 10'-0" UNLESS NOTED OTHERWISE SCALE: 1/4"= 1'-0" SCALE: 1/4"= 1'-0" (print on 24x36) SHEET NOTES WALL RECEPTACLE FOURPLEX (print on 2436) �— WALL RECEPTACLE VOICE/DATA HVAC SUPPLY AND RETURN GRILLES - DIMENSIONS ARE TO FACE OF WALL FINISH, TO r r PLAN NOTES O DRAWN: ksm SHOWN FOR REFERENCE CEILING KEYED NOTES CENTERLINE OF FRAMING, OR EDGE OF JUNCTION BOX PROVIDE SUPPLY AND RETURN IN EACH CASEWORK AS INDICATED ON PLAN ';}�, ; 1 . CASEWORK AND PLUMBING FIXTURES BY IKEA TO BE SUPPLIED BY CHECKED: MJ OCCUPIED ROOM. PROVIDE ZONE 1 . EXISTING 2' x 4' CEILING GRID TO REMAIN REMOVE EXISTING OUTLETS TENANT. CONTRACTOR TO INSTALL. PLAN FOR APPROVAL THROUGHOUT AS SHOWN ON PLAN. DATE: • CLEAR DIMENSION ARE FROM FACE OF w'ALL PROVIDE NEW 2' x 4' CEILING TILE HEIGHT OF OUTLET FROM FF TO 2. CONTRACTOR TO PROVIDE NEW PLASTIC LAMINATE COUNTERTOP. LIGHT SWITCH THROUGHOUT. VERIFY SPEC. WITH FINISH TO FACE OF WALL FINISH OR EDGE OF +46" CENTERLINE OF OUTLET. HEIGHT TO BE REVIEW SET 30 JUN 2021 VERIFY SWITCHING WITH TENANT DESIGNER. CASEWORK TO EDGE OF CASEWORK 18" A.F.F. UNLESS NOTED OTHERWISE. 3. APPLIANCES BY TENANT. REVIEW SET 8 JUL 2021 ON SITE. • DOOR AND RELITE DIMENSIONS ARE TO PERMIT SET 8 JUL 2021 CENTERLINE OF OPENING UNLESS NOTED 2. SWITCH FOR LIGHT IN DOOR JAMB - 4. KEEP DOOR FRAME TIGHT TO END OF BEARING WALL TO MAXIMIZE PRESSURE ON OFF OTHERWISE. DOORS NOT DIMENSIONED TO BE WIDTH OF ROOM PATIENT 3 107. LOCATED 4" FROM FACE OF WALL FINISH TQ 5. RELOCATED FIRE RATED WALL UNDER BUILDING STAIRS. VERIFY HINGE EDGE OF OPENING. CONSTRUCTION AFTER DEMO. PROVIDE 5/8" FIRECODE GYPSUM • PROVIDE SHEET METAL BACKING AS REQUIRED BOARD TO NEWLY EXPOSED UNDERSIDE OF STRINGERS. MAINTAIN 1 IN WALL FRAMING TO SUPPORT WALL AND HOUR FIRE RATED CORRIDOR/STAIR ENCLOSURE. PERMIT SET CEILING MOUNTED CASEWORK, EQUIPMENT, 6. RELOCATED (FROM DEMOLITION) SEMI RECESSED FIRE EXTINGUISHER FLOOR PLAN DOOR TRACKS AND OTHER ACCESSORIES THAT CABINET. MOUNT SO THAT TOP OF FIRE EXTINGUISHER AND OR DOOR MIGHT REQUIRE SUPPORT. VERIFY ALL PULL IS AT 48" MAX A.F.F. LOCATION WITH TENANT REP. PRIOR TO GYP. BD INSTALLATION. 7. TENANT SUPPLIED SINK AND FAUCET. IKEA VATTUDALEN SINGLE BOWL • SEE SHEET A4.1 FOR DOORS AND HARDWARE. TOP MOUNT SINK WITH YTTRAN FAUCET WITH PULL OUT SPRAY. All 8. WATER COOLER EXISTING EXTERIOR RECESSED CAN LIGHT WINDOW 36 15- :. T5 Align soffit with // — N m window head — a c4 36 U 15 PLASTIC LAMINATE N PLASTIC O CEPTPEN Ol03 \ 30 PEN COUNTER AND SPLASH L a PLASTIC LAMINATE LAMINATE o �� 12 TRANSACTION COUNTER \ TRANSACTION o COUNTER FRAME WALL `4, — — o r� v M 10 N c14) p co 102 24 24 • N 30 30 N' A: EAST B: NORTH C: SECTION A: NORTH L cn p' WAITING 101 2 NURSE 102 A _2 3/8" = 1'-0° A3.2 3/8" = 11-0" C�•���Z J CASEWORK GENERAL NOTES Y w 1 . CABINETS NEW CABINETS - IKEA SEKTION WHITE SIZES/FUNCTION SHOWN ON ELEVATION. CABINETS TO BE PURCHASE AND ASSEMBLED 36 36 36 BY TENANT. INSTALLATION TO BE BY CONTRACTOR PER .15 MANUFACTURER'S RECOMMENDATIONS. VERIFY CABINET ' 20` 20 20 SIZES IN FIELD PRIOR TO TENANT PURCHASE. DIMENSIONS OF CABINET GIVEN IN THIS ORDER: Width Depth ----- --- ----- --- ----- --- --- Height / 15 15 15 PLASTIC LAMINATE N 30 30 30 COUNTER AND SPLASH 2. HARDWARE: BY IKEA - INCLUDED IN TENANT PURCHASE ANDAY j CV ASSEMBLY O_ N \ 3. FINISH: WHITE o Qo : 0 ,24 .' - — iREFR. � � 4. COUNTERTOPS AND 4" SPLASH WHERE SHOWN BY QJ efiear — :20W x CONTRACTOR. PLASTIC LAMINATE TO SELECTED ' • ;33.5H 0; M � / � O � 5. INDIVIDUAL CASEWORK DIMENSIONS ARE INDICATED ON THE p 108 v INTERIOR ELEVATIONS AND DETAILS. 18 36 � 15 24 24 30 30 N qp 6. SHELVING SHOWN DASHED WHERE CONCEALED. L Qj A: NORTH B: NORTHEAST Q E > 108„ 7. PROVIDE FILLER PANEL AT ALL CASEWORK/WALL Q INTERSECTIONS. co 3 BREAK 108 C A3.2 3/8" = 1'-0" 3 L0 CV VERIFY WIDTH AND FIT PRIOR TO CABINET PURCHASE 36 30 30 36 36 36 15. . . : . . 15 15 15. i5. i5 15 ... DRAWN: ksm __ ____ INFILL AT -------------------------- INFILL AT CORNER CORNER CHECKED: MJ --------- -------- DATE: 3 : 36. REVIEW SET 30 JUN 2021 15' 15 1.5 : 15 .15 . v 15 REVIEW SET 8 JUL 2021 15 .0 30,• :. 30 30 fl� : 3U N 30 PERMIT SET 8 JUL 2021 -------- ---------- ------ ------- 30 36 36 12 47 JU 24 24 24 24 24 24 PERMIT SET 30 30 30 30 30 30 INTERIOR ELEVS A: SOUTH B: WEST C: NORTH a LAB 110 A3.2 3/8° = 1'-0" Al I DOOR SCHEDULE Door Room Name Size Door Door Door Frame Frame Frame Hardware Comments # & # (width-ht.) Type Material Finish Type Material Finish Group Existing door, frame and hardware to ALL PARTITIONS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE y remain. Existing assembly is 20 mino REQUIREMENTS OF THE SPECIFIC MATERIALS MANUFACTURER AND INDUSTRY 101 Waiting 101 36 - 96 A Wood/ Glass Stained KD Steel F.F. 1 rated. Cut out existing door and add STANDARDS. new full lite with steel rated frame and BLOCKING IS REQUIRED AT THE FOLLOWING LOCATIONS: WALL MTD. a 20 min rated firelite glazing V a CABINETS, ACCESSORIES, EQUIPMENT, DOORSTOPS, HOLD-OPENS, TOILET v� o Provide 3M dusted crystal film at full lite. ROOM ACCESSORIES AND OTHER LOCATIONS AS REQUIRED BY _ wry 102 Nurse 102 36 - 96 A Wood/ Glass Stained KDl Steel F.F. 3 MANUFACTURER SPECIFICATIONS OR INDUSTRY STANDARDS. '' o a 104 Office104 36 - 96 A Wood/ Glass Stained KDl Steel F.F. 2 Provide 3M dusted crystal film at full lite. a . 105 Patient 1 105 36 - 96 A Wood/ Glass Stained KD 1 Steel F.F. 3 Provide 3M dusted crystal film at full lite. 106 Patient 2 106 36 - 96 A Wood/ Glass Stained KD1 Steel F.F. 3 Provide 3M dusted crystal film at full lite. 107 Patient 3 107 36 - 96 A Wood/ Glass Stained KDl Steel F.F. 3 Provide 3M dusted crystal film at full lite. PERPENDICULAR TO JOISTS PARALLEL TO JOISTS 108 Break 108 36 - 96 A Wood/ Glass Stained KD1 Steel F.F. 3 Provide 3M dusted crystal film at full lite. 1 1 1 Storage 111 36 - 80 B Wood Painted - - - 4 BOTTOM CHORD OF 1 3/8 TRUSS BRACE BACK TO STRUCTURE W/ :\ METAL" STUDS 25GA. AT 8'-0" O.C. HARDWARE GROUPS (ALTERNATING) W/ 3-#8SHT. MTL. FRAME TYPES DOOR TYPES SCREWS TO TOP TRACK AND ROOF U SEE SHEET G1 .2 FOR ADDITIONAL HARDWARE STRUCTURE ABOVE 1/4 U-0„ 1/4 U-0„ COMMENTS KNOCKED DOWN (KD) FRAMES: INTERIOR DOORS TO BE SOLID CORE - TIMELY CLASSIC FRAME C-SERIES IN 1-3/4" THICK - GROUP 1 : EXISTING HARDWARE TO REMAIN FACTORY FINISH COLOR TO BE MATCH EXISTING STAIN & VENEER OF 1 EA LEVER LOCKSET - ENTRY FUNCTION - CASING T-8 DOOR 101 CEILING AS SCHEDULED 1�� DETERMINED Z 4 EA HINGES PROVIDE 3" THICK ROCK SEE REFLECTED CEILING 4 O Tempered safety 1 EA CLOSER WOOL SOUND INSULATION AT PLAN 6" 6„ glass 1 SET SMOKE GASKETING WALL TYPE Al IN LIEU OF R1 1 Q, N p� 1 EA WALL STOP PROVIDE NEOPRENE CLOSURE '� Al PROVIDE 5/8" QUICK ROCK EACH SIDE OF WALL A' ° GROUP 2: PANELS ON ONE SIDE AT WALL 3 5/8" 25 GA. METAL 1 EA LEVER STYLE OFFICE FUNCTION LOCK TYPE Al IN LIEU OF STD GYP STUDS @ 24" OC SEE DETAIL 3/A4.1 4 EA HINGES BD. INSTALL PER MANUF 1 EA WALL STOP RECOMMENDATIONS _ C? R-11 FIBERGLASS GROUP 3: SOUND 5/8" TYPE "X" GYPSUM Ll 1 EA LEVER STYLE LATCHSET PASSAGE INSULATION BOARD EA. SIDE 4 EA HINGES BASE AND FLOORING AS A B 1 EA WALL STOP SCHEDULED KD-1 FLUSH BI FOLD SWING HINGED GROUP 4: 3 5/8" X 20 GA CONTINUOUS BOTTOM +_ FULL LITE 1 EA BI FOLD DOOR TRACK, ROLLERS SET TRACK W/ (2)# 8 SHEET METAL SCREWS N 6 EA HINGES CV 1 EA PULL X0.145" DIA. X 3/4" DEPTH DRIVE PIN AT 16" O.C., TYP. E 09250 16 GA b" MIN. STUD AT � INTERIOR PARTITION- NON-RATED - NON-BEARING O n 1 BRACE LOCATIONS: REF A4.1 1 1/2"= F-0" V J PARTITION TYPES O CUT AND BEND FLANGE, TYP. o iL PERPENDICULAR PARALLEL TO JOISTS 0. TO JOISTS SECURE BACKING STUD TO 3 STUDS MIN. EXTEND Q FULL LENGTH OF WALL AT CABINETS OR -r- SHELVING. SHELVING. COORDINATE LOCATIONS WITH HANDRAILS, CABINET WORK, DOOR HARDWARE, ° 1 � WALL MOUNTED EQUIPMENT, ETC. _ / STEEL CLIP 4" X 1-1/2" > TYPICAL BACKING NOTES: // LEGS X 3" LONG - 16 GA. > FOR BACKING PLATE FOR MISC. ITEMS (i.e. SURFACE MOUNTED ITEMS) WITH MAX. WALL 3 5/8" METAL FASTEN TO JOIST WITH (2) N HEIGHT OF 50 Ibs.: // // USE 6INCH, 16 GA. HORIZONTAL TRACK (OR PLATE) NOTCHED AT EACH STUD. ANCHOR TO SPANNING FROM JOIST / �/ 3/8" DIA WOOD SCREWS ,— WALL STUDS WITH #12 SELF-TAPPING SHEET METAL SCREWS, (3) PER STUD. TO JOIST. ANCHOR TO / & 1 1/2" EMBED LO JOIST WITH 3/8" WOOD (3) SELF / CV FOR BACKING PLATE FOR MISC. ITEMS (i.e. SURFACE MOUNTED ITEMS) WITH A WEIGHT SCREWS - PROVIDE 1-1/2" TAPPING #8 / 3-5/8" x 20 GA METAL STUD GREATER THAN 50 Ibs. BUT NOT EXCEEDING 2000 Ibs.: EMBED INTO JOIST. SCREWS BRACE - CENTER IN WALL - USE 6 INCH, 16 GA. HORIZONTAL S-UD NOTCHED AT EACH STUD. WELD TO EACH VERTICAL 8'-0" O.C., BRACE TO STUD WITH A 1/16"X 2" FILLET WELD ON BOTH SIDES OF THE STUDS. ALSO WELD BOTH FLANGES STEEL CLIP 4" X 1-1/2" STRUCT.- ALTERNATE SIDES OF HORIZONTAL BRACING TO WALL STUDS WITH A 1/16"X 3/8" FILLET WELD ALL SIDES. LEGS X 3" LONG - 16 GA. �2 WALL BLOCKING 4.1 r'= 1,4' GYPSUM BOARD, METAL STUDS AND SOUND SUSPENDED CEILING SEE INSULATION REFLECTED CEILING PLAN DRAWN: ksm 4" MIN.@ SEE WALL TYPE LAP (2) 3"X48" ROCK WOOL 20 GA TRACK - FASTEN TO STUDS CHECKED: MJ HINGE SIDE TIMELY TA-8 CASING INSULATION OVER TOP OF W/ #8 SHEET METAL SCREWS EA WALL SIDE, EA STUD DATE: TIMELY KNOCK-DOWN REVIEW SET 30 JUN 2021 FRAME 3" ROCK WOOL 3 5/8" 25 GA. METAL REVIEW SET 8 JUL 2021 GLAZING SOUND STUDS @ 24" OC INSULATION PERMIT SET 8 JUL 2021 1/8"' 3/4.. 5/8" QUIET ROCK PANEL 5/8" TYPE "X" GYPSUM FLUSH WOOD STOPS INSTALLED PER MANUF BOARD EA. SIDE DOOR - SEE SCHEDULE RECOMMENDATIONS BASE AND FLOORING AS FACE OF SCHEDULED PERMIT SET PERPENDICULAR 3 5/8" X 20 GA CONTINUOUS DETAILS / DOORS WALL BOTTOM TRACK W/ (2)# 8 SHEET I B METAL SCREWS 0.145" DIA. X 3/4" DEPTH � DOOP, JAMB / HEAD DRIVE PIN AT 16" O.C., TYP. A49 3 a.1 3'= V-0" a:) WALL TO 6" ABOVE CEILING- NON-RATED - NON-BEARING A4.1 1 1/2"= 1'-0"