Loading...
Plans (24) BUP2020 -00106 Lf SUITE 100 & SUITE 210 DEMOLITION PLANS ARCH I T E C T S RECEIVED ` ' {� 720 NW Davis 503.221.1121 RECEI V EQ Suite 300 503 221.2077 'u TRIANGLE POINTE ;APR 14 zozo Portland OR 97209 www lrsarchitects.com CITY OF TIGARD BUILDING DIVISION 13333 SW 68TH PKWY, TIGARD , OR 97223 ,� � VALIDITY OF PERMIT THEsown PERMIT SET 04sl0m2020 THE ISSUANCE OFA PERMIT BASED ON CONSTRUCTION � DOCUMENTS AND OTHER • DATA SHALL NOT PREVENT t W THE CODE OFFICIAL FROM rr���� REQUIRING THE CORRECTION OF ERRORS. OSSC 105.4 CONSULTANT: PROJECT DIRECTORY CODE SUMMARY GENERAL NOTES 1. THE GENERAL NOTES ARE INTENDED TO CONVEY DESIGN INTENT OFFICE COPY OWNER REPRESENTATIVE: I. PROJECT INFORMATION: V. EMERGENCY SYSTEM STANDARDS: NOT OTHERWISE STATED IN THE DRAWINGS. DEACON DEVELOPMENT GROUP CONTACT PERSON PROJECT NAME: SUITE 100 & SUITE 210 DEMOLITION PLANS 2. ALL WORK SHALL CONFORM TO THE CODES REFERENCED IN THE CITY OF TIGARD 901 NE GLISAN ST, SUITE 210 RYAN SCHERA RYAN.SCHERA@DEACON.COM PROJECT ADDRESS: 13333 SW 68th PARKWAY 1. IF BUILDING IS FULLY SPRINKLERED (NEPA 13 MAKE CODE MINIMUM CORRECTIONS PROJECT SUMMARY AND TO CONDITIONS AND SPECIFICATIONS OF REVIE Ell FOR CODE COMPLIANCE PORTLAND, OR 97232 IAN LEWALLEN IAN LEWALLEN@DEACON.COM SUITE 100 & SUITE 210 ) ALL GOVERNING AUTHORITIES. TIGARD, OREGON 97223 AS REQUIRED PER NEW PLAN. IN BUILDINGS WITH EXISTING SMOKE DETECTORS: Approved: NWWV.DEACON.COM PROVIDE CODE MINIMUM CORRECTIONS AS REQUIRED. SMOKE DETECTORS TO BE 3. THE SITE PLAN AND SUITE LOCATION PLAN ARE FOR REFERENCE OTC: 7:503297.8791 PROJECT DESCRIPTION: EXISTING TENANT HAS VACATED SUITES 100 &210. OWNERSHIP TIED TO THE BUILDING ALARM SYSTEM. PROPERTY ID: W ONLY. SEE ALL OTHER SHEET PLANS FOR CONTRACT DOCUMENT I EXISTING WOULD LIKE TO PREP THE SUITES WITH SELECTIVE 2. IN BUILDINGS EQUIPPED WITH AN EXISTING VISUAL STROBE SYSTEM: PROVIDE CODE INFORMATION. THE PROJECT SUMMARY IDENTIFIES SOME SPECIFIC Address:#: DEMOLITION TO MAKE THEM MORE MARKETABLE TO POTENTIAL ROSSCEQUIREMENTS.REQUIREMENTS BUT IS NOT INTENDED TO LIST ALL OSSC Adilress: ARCHITECT: TENANTS. MINIMUM CORRECTIONS AS REQUIRED. IF A SYSTEM DOES NOT EXIST, DO NOT ADD REQUIREMENTS. .3 S LRS ARCHITECTS CONTACT PERSON ONE. 4, ALL WORK INDICATED ON DRAWINGS SHOULD BE CONSIDERED Suite #: O II.JURISDICTIONAL CODES: 3. PROVIDE EMERGENCY SYSTEM LIGHTING WITH NO LESS THAN 1 FOOT-CANDLE AT THE NEW AND IN CONTRACT UNLESS NOTED OTHERWISE. 720 NW DAVIS, STE 300 DARCIE MCCONNAHA FLOOR LEVEL ALONG ENTIRE EGRESS PATH PER CURRENT NATIONAL ELECTRICAL By: Date: PORTLAND, OR 97209 dmcconnah@Irsarchitects.com 2018 INTERNATIONAL BUILDING CODE (IBC) CODE REQUIREMENT. -1-'��) www.Irsarchitects.com 2019 OREGON STRUCTURAL SPECIALTY CODE (OSSC) 4. PROVIDE EXIT SIGNAGE. EXIT SIGNAGE SHALL BE CONNECTED TO BUILDING POWER T:503.221.1121 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) SUPPLY WITH BATTERY BACK-UP FOR MIN 1-1/2 HOUR DURATION. EVERY 100' IN 2019 OREGON MECHANICAL SPECIALTY CODE (GMSC) 2018 INTERNATIONAL FIRE CODE CORRIDORS, AND IN SPACES WHERE 2 MEAN OF EGRESS ARE REQUIRED PER GENERAL CONTRACTOR: 2019 OREGON ZERO ENERGY READY COMMERCIAL CODE (OZERCC) SECTION 1013. SEE ELECTRICAL DRAWINGS. (W/POCHE INDICATING "EXIT"TEXT SIDE DEACON CONSTRUCTION LLC CONTACT PERSON 2017 OREGON PLUMBING SPECIALTY CODE (OPSC) OF SIGN) SIGNS SHOWN IN CORRIDORS ARE CEILING HUNG. SIGNS SHOWN ON WALL 901 NE GLISAN ST, SUITE 210 ARMAND MILAZZO/JEFF SCOTT 2017 OREGON ELECTRICAL SPECIALTY CODE (OESC) ARE WALL HUNG. LEGEND (SEE LOCATION PLAN BELOW) PORTLAND, OR 97232 armand.milauo@deacon.com 2009 ICC-ANSI Al 17.1 5. PROVIDE CODE MINIMUM FIRE ALARM CONNECTIONS AS REQUIRED. CCB#212549 jeff.scott@deacon.com III. BUILDING STANDARDS: 6. SURVEY EXISTING CONDITIONS OF ENTIRE FLOOR THAT PROJECT OCCURS,AND AREA OF WORK 7:503.297.8791 PROVIDE NOT LESS THAN ONE APPROVED FIRE EXTINGUISHER WITH RATING OF NOT BUILDING TYPE: TYPE II-A LESS THAN 2A 10B/C FOR EACH 1,500 S.F. OF FLOOR AREA OR FRACTION THEREOF. DRAWING INDEX BUILDING OCCUPANCY: B TRAVEL DISTANCE TO AN EXTINGUISHER FROM ANY PORTION OF THE BUILDING B OCCUPANCY GROUP TOTAL NUMBER OF STORIES: 4 SHALL NOT EXCEED 75 FEET. PROVIDE FIRE EXTINGUISHER IN ACCORDANCE WITH SHEET NUMBER SHEET NAME CURRENT CODES. PROVIDE NEW FIRE EXTINGUISHER AT ALL EXISTING CABINETS ® ®� EXIT SIGN w/INTEGRATED DIRECTIONAL ARROW WHERE AREA(S) OF WORK: WHERE MISSING. ALL REUSED EXISTING FIRE EXTINGUISHERS ARE TO BE INSPECTED OCCURS AT ALL EXITS, EVERY 100'IN CORRIDORS, AND/N SUITE 100 AREA: +/-22,501 R.S.F. AND/OR RECHARGED, AS NECESSARY, JUST PRIOR TO SUBSTANTIAL COMPLETION, SPACES WHERE 2 MODES OF EGRESS ARE REQUIRED PER CS COVER SHEET TOTAL SUITE 100 OCCUPANT LOAD: 150 (B-OCCUPANCY; OCC LOAD FACTOR- 150) 7. CONTACT OWNERS REPRESENTATIVE FOR INSTRUCTIONS WHEN SCHEDULING WORK SECTION 1011. (REFER TO ELECTRICAL DRAWINGS FOR MORE AD201 SUITE 100 DEMOLITION PLANS ON FIRE SPRINKLER &ALARM SYSTEMS. AD202 SUITE 210 DEMOLITION PLANS SUITE 210 AREA: +/-7,303 R.S.F. INFORMATION). POCHE INDICATES "EXIT"TEXT SIDE OF SIGN. SIGNS SHOWN/N CORRIDORS ARE CEILING HUNG. SIGNS TOTAL SUITE 210 OCCUPANT LOAD: 49 (B-OCCUPANCY; OCC LOAD FACTOR- 150) SHOWN ON WALL ARE WALL HUNG. PROJECT NUMBER: 220103 IV.ADA ACCESSIBILITY UPGRADES BUILDING HAS BEEN UPGRADED ACCORDING TO THE ACCESSIBILITY UPGRADES LIST AS Suite 100 & 210 OUTLINED IN OSSC 3411. UNDER SEPARATE PERMIT AS REQUIRED Demo Plans MECHANICAL SYSTEMS Triangle Pointe ELECTRICAL SYSTEMS, INCLUDING EGRESS LIGHTING g PLUMBING SYSTEMS SPRINKLER SYSTEMS 13333 t Parkway FIRE ALARM/DETECTION SYSTEMS Tigard, OR 97223 AREAS OF WORK 0 0 SITE LOCATION TRIANGLE POINTE • umnie way !, b I / n E1 �a� SWVe 11,%, tMerce�Suo,�pe Vmrr�Yo,nPceni � 1 /i®� �na�rt ui� � � ,`\`fe'�`\ ` 1 � / ❑ la,dnaeM®•iml - W+n um W. s VIIMNMe 0 \�\` \\y- , GGff EXISTING EXISTING i sw pr s, aw OCCUPANCY OCCUPANCY a SHEET TITLE: '"� •'�"�"°"""°^ \ m I 'NOTE:OCCUPANCY 'NOTE.OCCUPANCY COVERSHEET g \ o I UNDER FUTURE UNDER FUTURE ❑ R ) • + PERMIT. EGRESS PERMIT. EGRESS AND OCCUPANCY AND OCCUPANCY w11Me�f^9 s I nmowti; TO BE DETERMINED TO BE DETERMINED ti �ra •roucmw - m.w.n \ ' 1 nus .a..:yo• • _ =.m• \ \,� �` - I WITH FUTURE WITH FUTURE o CITY OF TIGARD \ \ \ TENANT TENANT Approved b Planning IMPROVEMENT IMPROVEMENT Date: o iy.e-r„e.m Hy ` � '"v um,tea.�r,e,•rl r` �Yhi \ \ m�_'.y _ I ❑ 5e�j wrooi a.u�i �w . m•.mu+u \ \ o DRAWN BY: SJB DATE ISSUED: 04.10.20 a m N N N ,`, N 0 VICINITY MAP SITE PLAN SUITE 100 AREA OF WORK SUITE 210 AREA OF WORK SCALE: NOT TO SCALE SCALE.'NOT TO SCALE SCALE: NOT TO SCALE SCALE: NOT TO SCALE a TRUE NORTH TRUE NORTH PLAN NORTH TRUE NORTH PLAN NORTH SHEET: E r N LRSArchitects,Inc.02020 SUITE 100 DEMOLITION PLAN GENERAL NOTES DEMOLITION PLAN LEGEND SUITE 100 DEMOLITION R.C.P. GENERAL NOTES DEMOLITION R.C.P. LEGEND Lf A. THIS DRAWING DEPICTS EXISTING CONDITIONS FOR REFERENCE ONLY. VERIFY ALL DIMENSIONS EXISTING TO REMAIN A. THIS DRAWING DEPICTS EXISTING CONDITIONS FOR REFERENCE ONLY. VERIFY ALL CONDITIONS PRIOR TO EXISTING TO REMAIN A R C H I T E C T S AND CONDITIONS PRIOR TO START OF WORK AND REPORT ALL DISCREPANCIES TO ARCHITECT. START OF WORK AND REPORT ALL DISCREPANCIES TO ARCHITECT. B. DIMENSIONS ARE TO FACE OF FINISH, UNO. DIMENSIONS NOTED TAKE PRECEDENCE OVER — — DEMOLISH EXISTING ELEMENT- REMOVE ALL B. PROTECT ALL ADJACENT AREAS DURING DEMOLITION AND FROM DUST AND TRASH INTRUSION. _ _ _ DEMOLISH EXISTING ELEMENT- REMOVE ALL 720 NW Davis 503.221.1121 It SCALE. ELECTRICAL AND LOW VOLTAGE WIRING/CONDUIT IN C. CEILING CONFIGURATION TO REMAIN. EXISTING CEILING CONFIGURATION, EXISTING LIGHTING, AND ELECTRICAL AND LOW VOLTAGE WIRING/CONDUIT IN Suite 300 503 221.2077 v C. PROTECT ALL ADJACENT AREAS DURING DEMOLITION AND FROM DUST AND TRASH INTRUSION. DEMOLISHED WALLS EXISTING MEP SCOPE TO BE VERIFIED IN FIELD. DRAWING IS SHOWN FOR REFERENCE ONLY. DEMOLISHED WALLS D. REMOVE AND SALVAGE DOORS, FRAMES, HARDWARE AND RELITES FOR REUSE. D. HANG EXISTING EXIT SIGNS ABOVE DOORS(S) OR FROM CEILING AS REQUIRED TO MEET CODE FOR CORE Portland OR 97209 www.irsarchitects.com E. REMOVE AND SALVAGE FIRE EXTINGUISHER AND CABINETS FOR REUSE. ® AREA NOT IN SCOPE AND SHELL EGRESS. SALVAGE EXCESS EXIT SIGNS AND MOUNTING BOXES FOR OWNER'S STOCK. AREA NOT IN SCOPE F. REMOVE EXISTING FLOORING & BASE, INCLUDING GLUE, DOWN TO CONCRETE. E. SPRINKLER LOCATIONS TO REMAIN AS IS -ALTER AS REQUIRED TO MEET CODE FOR CORE AND SHELL G. WHERE WALLS ARE TO REMAIN, PATCH SHEET ROCK& PREP WALL TO RECEIVE PAINT WHERE COVERAGE. PERPENDICULAR WALL(S) WERE REMOVED. F. REMOVE ALL ANCHORAGES AND ATTACHMENTS ABOVE CEILING GRID FOR WALLS THAT WERE REMOVED. EXISTING 2x4 ACOUSTICAL SUSPENDED CEILING H. REPAIR ANY DAMAGED WINDOW MULLIONS, SILLS OR TRIM AT PERIMETER OF BUILDING, WHERE G. IF NOT ALREADY EXISTING, PROVIDE EGRESS LIGHTS AS NECESSARY TO MEET CODE MINIMUM LIGHT WALL(S) WERE REMOVED. LEVELS THROUGHOUT ENTIRE AREA OF WORK. �_aF� I. PATCH HOLES, DENTS, SCRATCHES, ETC TO PREP EXISTING WALLS FOR PAINT. H. ALL ELECTRICAL WORK IS DESIGN-BUILD- LIGHT FIXTURES SHOWN FOR REFERENCE ONLY. VERIFY EXISTING EXISTING BUILDING STANDARD LIGHT FIXTURE 11��11`"'�� J. INTERIOR WINDOW COVERINGS TO REMAIN. PROTECT EXISTING SHADES FROM DUST AND CONDITIONS. CLEAN AND RESTORE ALL LIGHTS TO REMAIN TO WORKING ORDER PRIOR TO JOB CJ DAMAGE DURING DEMO WORK. COMPLETION. E C $WRT K. REMOVE ALL LOW VOLTAGE CABLES- PROVIDE BLANK WHITE OUTLET COVERS. LEAVE IN PLACE I. ALL MECHANICAL WORK IS DESIGN BUILD-VERIFY EXISTING CONDITIONS. CLEAN ALL DIFFUSERS TO REMAIN ALL LOW VOLTAGE FOR HVAC, FIRE LIFE SAFETY SYSTEMS, AND SECURITY LINES. DEMOLITION PLAN KEYNOTES PRIOR TO JOB COMPLETION. L. TIE UP THERMOSTATS AT WALLS TO BE REMOVED FOR FUTURE TENANT IMPROVEMENT. J. REPAINT ALL CEILING HEADERS AND SOFFITS TO REMAIN IN ENTIRE AREA OF WORK WITH BUILDING DEMOLITION R.C.P. KEYNOTES • M REMOVE ALL TACK PANELS, WHITEBOARDS, PLYWOOD, ETC FROM WALLS TO REMAIN, UNLESS STANDARD GENERAL WALL PAINT COLOR. ,%FWrLANI { OTHERWISE NOTED. PATCH AND PREP FOR PAINT. O REMOVE ALL CARPETING THROUGHOUT SCOPE OF WORK. SEE O EXISTING CEILING SYSTEM, LIGHTING, ETC TO REMAIN. LAYOUT OF N. REPAINT ENTIRE AREA OF WORK WITH BUILDING STANDARD GENERAL WALL PAINT COLOR, GENERAL NOTES. CEILING AND FIXTURES SHOWN FOR REFERENCE ONLY. VERIFY Qri INCLUDING EXISTING WALLS, SOFFITS AND HEADERS TO REMAIN. EXISTING CONDITIONS IN FIELD. 2O REMOVE RAISED FLOOR OFFICE AREA. O2 REPAINT EXISTING HEADERS AND SOFFITS IN AREA OF WORK. SEE GENERAL NOTES. CONSULTANT: ® LI —_- ----��----_---� 2 2 PROJECT NUMBER: 220103 1 ® ® 1Nil Suite 100 & 210 Demo Plans Triangle Pointe 9 13333 SW 68th Parkway 2 Tigard, OR 97223 loll 1 U 2 a SHEET TITLE: 1 s SUITE 100 0 s DEMOLITION 1 PLANS a 0 0 FL DRAWN BY: SJB 0 DATE ISSUED: 04.10.20 a 0 a v 0 0 N N 0 1. SUITE 100 DEMOLITION PLAN 2. SUITE 100 DEMOLITION REFLECTED CEILING PLAN z SCALE: 1116"= 1'-0" SCALE: 1/16"= 1'-0" a a SHEET: D201E m LRS Architects,Inc 0 2020 w 0 `w SUITE 210 DEMOLITION PLAN GENERAL NOTES DEMOLITION PLAN KEYNOTES SUITE 210 DEMOLITION R.C.P. GENERAL NOTES DEMOLITION R.C.P. KEYNOTES Lf A. THIS DRAWING DEPICTS EXISTING CONDITIONS FOR REFERENCE ONLY. VERIFY ALL DIMENSIONS 1O EXISTING DATA LINE CONDUIT TO BE DEMOLISHED. A. THIS DRAWING DEPICTS EXISTING CONDITIONS FOR REFERENCE ONLY. VERIFY ALL CONDITIONS PRIOR TO O EXISTING CEILING SYSTEM, LIGHTING, ETC TO REMAIN. HATCH FOR A R C H I T E C T S AND CONDITIONS PRIOR TO START OF WORK AND REPORT ALL DISCREPANCIES TO ARCHITECT. START OF WORK AND REPORT ALL DISCREPANCIES TO ARCHITECT. EXISTING SCOPE TO REMAIN SHOWN FOR REFERENCE ONLY.VERIFY B. DIMENSIONS ARE TO FACE OF FINISH, UNO. DIMENSIONS NOTED TAKE PRECEDENCE OVER O SERVER ROOM AND INTERIOR COMPONENTS TO BE DEMOLISHED, B. PROTECT ALL ADJACENT AREAS DURING DEMOLITION AND FROM DUST AND TRASH INTRUSION. EXISTING CONDITIONS IN FIELD. 720 NW Davis 503.221.1121 1T SCALE. C. CEILING CONFIGURATION TO REMAIN. EXISTING CEILING CONFIGURATION, EXISTING LIGHTING,AND Suite 300 503 221.2077 D C. PROTECT ALL ADJACENT AREAS DURING DEMOLITION AND FROM DUST AND TRASH INTRUSION. EXISTING BREAK ROOM CABINETRY AND PLUMBING FIXTURES TO O 2 REPAINT EXISTING HEADERS AND SOFFITS IN AREA OF WORK. SEE REMAIN. PROTECT DURING CONSTRUCTION. EXISTING MEP SCOPE BE VERIFIED IN FIELD. DRAWING IS SHOWN FOR REFERENCE ONLY. GENERAL NOTES. Portland OR 97209 www.irsarchitects.com D. REMOVE AND SALVAGE DOORS, FRAMES, HARDWARE AND RECITES FOR REUSE. D. HANG EXISTING EXIT SIGNS ABOVE DOORS(S)OR FROM CEILING AS REQUIRED TO MEET CODE FOR CORE E. REMOVE AND SALVAGE FIRE EXTINGUISHER AND CABINETS FOR REUSE. AND SHELL EGRESS. SALVAGE EXCESS EXIT SIGNS AND MOUNTING BOXES FOR OWNER'S STOCK. F. REMOVE EXISTING FLOORING& BASE, INCLUDING GLUE, DOWN TO CONCRETE, UNLESS O REMOVE AND CAP WASTE LINES FROM REMOVED ICEMAKER. E. SPRINKLER LOCATIONS TO REMAIN AS IS-ALTER AS REQUIRED TO MEET CODE FOR CORE AND SHELL O WHERE EXISTING WALLS ARE TO BE DEMO'D THAT CURRENTLY BREAK OTHERWISE NOTED. COVERAGE. EXISTING GRID TO REMAIN- CUT TOP OF WALL+-2" BELOW A.C.P.AND PRE-ACTION FIRE SUPPRESSION SYSTEM TO BE REMOVED. DEMOLISH BRACE UP TO STRUCTURE (IF NOT EXISTING). SEE DETAIL#3/AD202 G. WHERE WALLS ARE TO REMAIN, PATCH SHEET ROCK& PREP WALL TO RECEIVE PAINT WHERE O F. REMOVE ALL ANCHORAGES AND ATTACHMENTS ABOVE CEILING GRID FOR WALLS THAT WERE REMOVED. PERPENDICULAR WALLS)WERE REMOVED. SYSTEM AND ALL RELATED COMPONENTRY, IN ADDITION TO SPLIT G. IF NOT ALREADY EXISTING, PROVIDE EGRESS LIGHTS AS NECESSARY TO MEET CODE MINIMUM LIGHT FOR REFERENCE. VERIFY LOCATIONS IN FIELD. H. REPAIR ANY DAMAGED WINDOW MULLIONS, SILLS OR TRIM AT PERIMETER OF BUILDING, WHERE SYSTEM A/C. G.C. TO VERIFY SYSTEM REMOVAL PRIOR TO DEMOLITION. LEVELS THROUGHOUT ENTIRE AREA OF WORK. WALL(S)WERE REMOVED. H. ALL ELECTRICAL WORK IS DESIGN-BUILD- LIGHT FIXTURES SHOWN FOR REFERENCE ONLY. VERIFY EXISTING 13/8" op I. PATCH HOLES, DENTS, SCRATCHES, ETC TO PREP EXISTING WALLS FOR PAINT. CONDITIONS. CLEAN AND RESTORE ALL LIGHTS TO REMAIN TO WORKING ORDER PRIOR TO JOB J. INTERIOR WINDOW COVERINGS TO REMAIN. PROTECT EXISTING SHADES FROM DUST AND COMPLETION. 1111111iIB1EA MT 7 DAMAGE DURING DEMO WORK. I. ALL MECHANICAL WORK IS DESIGN BUILD-VERIFY EXISTING CONDITIONS. CLEAN ALL DIFFUSERS TO REMAIN K. REMOVE ALL LOW VOLTAGE CABLES-PROVIDE BLANK WHITE OUTLET COVERS. LEAVE IN PLACE PRIOR TO JOB COMPLETION. ALL LOW VOLTAGE FOR HVAC, FIRE LIFE SAFETY SYSTEMS,AND SECURITY LINES. J. REPAINT ALL CEILING HEADERS AND SOFFITS TO REMAIN IN ENTIRE AREA OF WORK WITH BUILDING EXISTING STRUCTURE L. TIE UP THERMOSTATS AT WALLS TO BE REMOVED FOR FUTURE TENANT IMPROVEMENT. STANDARD GENERAL WALL PAINT COLOR. M. REMOVE ALL TACK PANELS, WHITEBOARDS, PLYWOOD, ETC FROM WALLS TO REMAIN, UNLESS OTHERWISE NOTED. PATCH AND PREP FOR PAINT. OF N. REPAINT ENTIRE AREA OF WORK WITH BUILDING STANDARD GENERAL WALL PAINT COLOR, 20 GA,6"MTL.STUDS INCLUDING EXISTING WALLS, SOFFITS AND HEADERS TO REMAIN. (3)#8 SCREWS @ GLB(1)#8 (600S137-33)W/13/8" SCREWS @ 2X PURLINS FLANGES CONT. 20 GA. 3 1/2"MTL STUD (2)#6 SCREWS TYP.AT (3505137-33)W/13/8" CONSULTANT: FLANGE BRACE @ 8'-0" DEMOLITION PLAN LEGEND DEMOLITION R.C.P. LEGEND EACH STUD. O.C.W/(3)#8SCREWS + ++ AT EA. END ATTACHMENT EXISTING TO REMAIN EXISTING TO REMAIN MTC.STUDS(3625137-33) DEMOLISH EXISTING ELEMENTREMOVE ALL ELECTRICAL AND LOW VOLTAGE — — — DEMOLISH EXISTING ELEMENT-REMOVE ALL ELECTRICAL AND LOW VOLTAGE @ 24"O.C. WIRING/CONDUIT IN DEMOLISHED WALLS WIRING/CONDUIT IN DEMOLISHED WALLS 20 GA.TOP&BOTTOM _ AREA NOT IN SCOPE AREA NOT IN SCOPE METAL TRACK(362T150-33) EXISTING ACOUSTICAL SUSPENDED CEILING SYSTEM, LIGHTING, DIFFUSERS, ETC TO REMAIN CEILING HEIGHT ------------- A S NOTED SUSPENDED CEILING SYSTEM 3. SOFFIT DETAIL @ ACP SCALE: 1-1/2"= 1'-0" PROJECT NUMBER: 220103 Suite 100 & 210 Demo Plans Triangle Pointe 13333 SW 68th Parkway /i Tigard, OR 97223 / 3Ilk v 0 - A� ` '// \ 3 ` \ SHEET TITLE: ��,\ SUITE 210 DEMOLITION 5 PLANS a \\ ` DRAWN BY: SJB DATE ISSUED: 04.10.20 0 a d N N m 0 0 1. SUITE 210 DEMOLITION PLAN 2. SUITE 210 DEMOLITION REFLECTED CEILING DIAGRAM SCALE: 3/32"= V-0" SCALE: 3/32"= 1'-0" a SHEETA D202 E IRS Archikch,Inc.0 202 N a 8'