Loading...
Plans (11) M EC2021 -00586 Latimer HVAC RECEIVED CCB#220839 JUL 2 1 2021 CITY OF TIGARD BUILDING DIVISION b•SOlOSSO'SUOUd 30 N011038HOO 31-119NI 18038 W083 TJ101330 3003 3H1 \ Latimer`' mer l ,\ / /�H C 1FJ3N3A3FJd NON IIVH 0 � r n V H0(INV S1N3W 00 000 HEATING.VENTILATION.AIR CONDITIONING Outside Air Ventilation N0110nUiSNO0 NO 3SV9 1IWH3d V d0 30NVfl 1 3H1 AZ RP RA VBZ EZ VOZ I11Wa3d =10 AlK 11bn Room Code Max Ventilation Area Outdoor Exhaust Exhaust Scope of Work Description/n Room Area Occupant Density Occupancy Factor Air Rate Breathing Zone Air Distribution Zone Outdoor Airflow Rate Airflow Occupancy Classification Air Distribution Configuration umbers (SF) (People/1000 SF) (People) (CFM/Person) (CFM/SF) Ventilation (CFM) Effectiveness Airflow (CFM) (CFM) (CFM) Latimer HVAC will perform the following scope of work: SIM1 322 0 0 0.3 96.6 0.8 120.75 0 Gym, stadium, arena (play area) Ceiling supply and ceiling return 1. Replace existing with new rooftop gaspack unit on existing curb. Use curb clips. SIM2 670 0 0 0.3 201 0.8 251.25 0 Gym, stadium, arena (play area) Ceiling supply and ceiling return 2. Provide (1) ceiling mount exhaust fan for kitchen area. SIM3 410 0 0 0.3 123 0.8 153.75 0 Gym, stadium, arena (play area) Ceiling supply and ceiling return (�--�-'�--� 3. Ducting and air dis' :tion modifications as drawn. open 320 15 7.5 0.12 74.4 0.8 93 0 Sales (except as below) Ceiling supply and ceiling return 17- 2 " ¢ mlea AH1 1722 619 .#alp Equipment Schedule Sim 4 540 0 0 0.3 162 0.8 202.5 0 Gym, stadium, arena (play area) Ceiling supply and ceiling return ;ssarppV RTU1-. Existing 7.5-ton rooftop HP. 3000 cfm design. Sim 5 5401 0 0 0.3 162 0.8 202.5 0 Gym, stadium, arena (play area) Ceiling supply and ceiling return - V 11"342 RTU2-. Existing 5-ton rooftop HP. 1620 cfm design. RTUI 1080 405 I -0Z0 RTU3-. New Carrier 50TCQD08A2A5. 7.5-ton package HP. 18.6KW electric supplementary heater. kitchen 300 0 0 0 0 0.8 0 210 290 Kitchen (cooking) Ceiling supply and ceiling return y. 208/3/60- 68 MCA, 110 MOCP. 88,000 Btu cooling. 11.2 EER, 12.5 leer. 86Mbtu heating- COP 3.4. 3000 bar 300 100 7.5 0.18 279 0.8 348.75 0 Bar, cocktail lounges Ceiling supply and ceiling return CFM. 885# net. 70# economizer, 200#curb adapter, 200# existing curb and duct. Gross- 1355# open 700 15 7.5 0.12 162.75 0.8 203.4375 0 Sales (except as below Ceiling supply and ceiling return aartvrlaw0a aan0 x03 P g ( P ) g PP Y g AHI-. Existing air handler connected to 5-ton HP. Existing OSA. 1700 cfm design. men 105 0 0 0 0 0.8 0 100 120 Toilet room - public Ceiling supply and ceiling return �QUVDL .ti0 AMD ' EF1- Existing rooftop exhaust fan for restrooms- 240 cfm. women 105 0 0 0 0 0.8 0 100 120 Toilet room - public Ceiling supply and ceiling return d03 301:11:10 EFb Panasonic FV-30- 290 cfm @ 0.25sp. On switch. office 75 5 5 0.06 6.375 0.8 7.96875 0 Office space Ceiling supply and ceiling return RTU2 1585 560 Mechanical General Notes: sim6 375 0 0 0.03 112.5 0.8 140.625 0 jGym, stadium, arena (play area) Ceiling supply and ceiling return _--- lounge 500 100 7.5 0.18 127.5 0.8 159.375 0 Bar, cocktail lounges Ceiling supply and ceiling return 1. Cooling equipment does not exceed the load of the calculated requirement. RTU3 875 300 2. All steel ducting will be 26 ga minimum galvanized. Flex per Mfg. TOTAL 1884 530 3. Heating and cooling ducting to be designed to not exceed 0.5 we positive (supply) and 0.5 we negative FJO 9 OSW (return). 4. Provide programmable thermostat. 5 degree deadband minimum. 7 day. Microprocessor. Set program for - a34N311b' 0 V 1V 1VN01S night energy savings. d(1S 3181at1V 5. Seal ducting with UL listed mastic or mastic tape. Ventilation Requirements-based on 2019 OMSC table 403.3 A V 6. Fan motor does not exceed allowable, first available above BHP. -10 VH31V/111OV 7. Confirm smoke detectors on all units over 2000 cfm AH1- 313(3 3)IOINS 8. Provide 0 and M to building owner. SA= 1700 cfm OI1VAI LOV 3H I , RA= 1400 cfm - OSA= 300 cfm RTU 1- Ir- SA SA = 3000 cfm Z t U RA = 2350 cfm OSA =650 cfmLU O °1 Iu 3 r a ::3 oc RTU2- C ® 2 C•, SA= 1620 cfm Z C< CL ` RA= 1320 cfm Z w r- ~ .oD LLL / n CEJ OSA= 300 cfm t .4 ` LL N o �> RTU3- Ln Q SA = 3000 cfm ti I O RA= 2350 cfm OSA= 650 cfm CD e-I SUBMITTAL REVIEW ❑X NO EXCEPTIONS TAKEN ❑ REVISE AND RESUBMIT ❑ MAKE CORRECTIONS NOTED ❑ SUBMIT SPECIFIED ITEM CHECKING IS ONLY FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE INFORMATION IN THE CONTRACT DOCUMENTS.ANY ACTION SHOWN ABOVE IS SUBJECT TO THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS. CONTRACTOR IS RESPONSIBLE FOR: DIMENSIONS WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB SITE; FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION; COORDINATION OF THEIR WORK WITH THAT OF ALL OTHER TRADES;AND SATISFACTORY PREFORMANCE OF THEIR WORK. ORANGEWALLstudios architecture + planning 240 N Broadway Suite 308, Portland, OR 97227 BY: J. Erwin (OWS) DATE: 07/13/2021 I M0.0 - - CID co XLatimer HVAC Latimer HVAC CCB#220839 W HEATING•VENTILATION•AIR CONDITIONING W ! � Legend _ - - - - --- - -- - ' ® - Supply Diffuser - - - - - - - - - - -- -- --- -- - - --- - - - - --- - I - -- - - ---- - 0 - -- - -- - - - - -- - - -- - - - --- - - - - - ---- 2 - I Supply diffuser spiral JANITOR Air ir 104 - Return Grill A - Thermostat SIM 2 � SIM 1 (NJ ��CPM `��KITCHEN ROOFTOP MIENS (I I 105 ACCESS RES ROOM ® - Exhaust fan - - _ 7 - r CL-2 103 i +,o' -o" Existing —p— Ll t' FAI �N) U I9<1 ►CMD - +8E)6„ ICE) I I - - - - - � j � <I �ISupply duct IUL - �I - - 19 - - - - UI L J I III - Return duct III WOMENS m CL , Ca) Lu' W A4 (E) TELCO RESTROO�A - Neck size/ CFM � � �. : I w°w III + 3'-0" ZQ = L ° ct 2 III I 102 Volume dampers z ` BAR iE,Ck' �� ,Z � J 06 ( E PARTY RISER - - — - -- - -- - _� -ROOM- 0 ROOM - - — — - - - ----- - - -- - --- - -- --- - - - - - - - - - -- - I 107 OFFICE � -� Z .� '� — - — — I 2 101 uj uj I ti Lu Z V CL-2 0 W NI-� � � �y� ids i j°" ! w Q A'4� ( 1 V o \7 (k) lbw Z Q � II — o a � _ m to ° SIM3 SII °[ 7 Z < oo til ° J I j i 1 I\ ' I`� — — — -- — — — -- — — w (D I- g IL I v L I I <Nj ZZ I Q Z _ — — — — - — — — - - - - c !Cu I y I ����I Al / Z ° c=n a tui _ � tgns w W Z a (NI � -(Rep)4i�) �N 1- n,M QOCj;vL� LL lJc" J O ° � N Q IO I m ` III Hill IAI) II . IIII N I n � �� Iw uu L_. III CL-2 A401 L I I � w 1:- ILII 12- y r-AA 00 i F] F] tell ® LOUNGE 5'-o° SIM 4 SIM 5 100 i I I I i� Rod — — c4) ivy _ �I i z,N O Va -� -- — - I SUBMITTAL REVIEW ® NO EXCEPTIONS TAKEN ❑ REVISE AND RESUBMIT MAKE CORRECTIONS NOTED ❑ SUBMIT SPECIFIED ITEM - - -- - ---- — I- - CHECV4G IS ONLY FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE INFORMATION IN THE CONTRACT j DOCUMENTS.ANY ACTION SHOWN ABOVE IS SUBJECT TO THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS. CONTRACTOR IS RESPONSIBLE FOR: DIMENSIONS WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB SITE; FABRICATION PROCESSES / AND TECHNIQUES OF CONSTRUCTION; COORDINATION OF THEIR WORK WITH THAT OF Ham,!�e, ALL OTHER TRADES;AND SATISFACTORY PREFORMANCE OF THEIR WORK. ORANGEWALLstudios architecture + planning 240 N Broadway Suite 308, Portland, OR 97227 H __ PLAN 240 J. Erwin (OWS) DATE: 07/13/2021 M 1 •�