Loading...
Plans (15) M EC2021 -00203 IFFICE COPY OFFICE COPY - - - 17"SPE 18 19 19. 20 3-19-21 W GENERALNOTES 1. THE AS-BUILT DRAWINGS USED TO CREATE THESE DRAWINGS MAY NOT REFLECT EXACT ROUTING OR EXPIRES: 6-30-21 SIZES OF EXISTING DUCTWORK. MECHANICAL CONTRACTOR SHALL VERIFY ALL CONNECTION REQUIREMENTS IN FIELD PRIOR TO START OF WORK AND MAKE ADJUSTMENTS TO DESIGN AS REQUIRED. ALL WORK SHALL BE DONE PER STATE&LOCAL JURISDICTIONAL REQUIREMENTS. O(E)10'0 CD 2. GC TO PROVIDE FULL INSPECTION AT BEGINNING OF PROJECT ON ROOFTOP UNIT IN ALL HEATING AND RECEIVED 235 CMC MODES TO ENSURE PROPER OPERATION. PROVIDE FULL MAINTENANCE AND SERVICE ON (TYP OF 6) (E)10'9 ROOFTOP UNIT INCLUDING CLEANING FAN,HOUSING,SQUIRREL CAGE,MOTOR,CONDENSER FINS, ❑Jh1,950(E)24'x24- CFM RGO I REPLACE FILTER,FURNISH NEW FAN BELTS AS REQUIRED,LUBRICATE,SEAL AND FIX ANY DAMAGE AS MA 2 51021 (E)10'0 1,950 CFM NECESSARY.REPORT ANY MAINTENANCE ISSUES OR DEFICIENCIES TO KROGER PROJECT MANAGER& CITY OF TfGARD EXISTING ARCHITECT. 4BUILD NG DIVISION (E)14'0 AC 1 3. GCIS RESPONSIBLE TO INCLUDE IN THEIR BIDS ALL SENSORS,WIRING AND INSTALLATION FOR THE FM 31 REQUIRED MECHANICAL CONTROLS,CONTACT WAEL AT WYTEK CONTROLS(503.780.7871)FOR PRICING TO 1,950 CFM INCLUDE IN YOUR BID.NONE OF THESE ITEMS ARE FRED MEYER SUPPLIED. D S (E)22'0 EXISTING NG 4. OUTDOOR AIR IS SUPPLIED BY EXISTING DIFFUSERS FROM AC-31. RTF 1 DFC 1 (E)22"0 ' _�� 3,000 CFM (E)16'0 KEY NOTES (ME)�� rmm Ett O EXISTING MECHANICAL EQUIPMENT AND ASSOCIATED DUCTWORK TO REMAIN. C 4 (E110"0 I I \\ CD O REMOVE AND DISPOSE OF EXISTING DUCTWORK,SUPPLY DIFFUSERS OR RETURN GRILLES SHOWN DARK AND o o E / I \ DASHED. m 8 F _(D o coFj / O CONNECT NEW DUCTWORK TO EXISTING DUCTWORK AS SHOWN.VERIFY EXACT LOCATION IN FIELD. ^ 2 E 12"0 24"x12'LTG 1 d oo dui ?2 C Lou - -- I O O O O BALANCE ALL SUPPLY AND RETURN AIR REGISTERS FOR EXISTING AC-31 TO AIRFLOW VALUES LISTED ON PLAN. $ w 4 $ � D I(T E)30"X18'CDO AIR BALANCE SHALL BE PROVIDED BY GC.PROVIDE AIR BALANCE REPORT TO ARCHITECT FOR REVIEW BY -2w v E y Cl) (R)A 31 i / 1,0 CFM MECHANICAL ENGINEER. � m (9 w CO _ OF �1° w 0 U Q O GC TO COORDINATE WITH EMS CONTROLS CONTRACTOR TO RELOCATE EXISTING THERMOSTAT FOR AC-31. co, L x O(D)8"0 GC TO INSTALL AS SHOWN ON PLANS. '� o tvaw 3 `0 (E)18"0 NEW 12'X6'SIDEWALL SUPPLY REGISTER,TITUS MODEL 30ORS W1 TYPE 1 BORDER FOR SURFACE MOUNT, 12x12"STG(D 314'BLADE SPACING,DOUBLE DEFLECTION,OPPOSED-BLADE DAMPER.FACTORY WHITE FINISH, 540 CFM EXISTING O `� �---------- 111 _ _ . . L--------- --------- DFC 2 1 �FF10E CCS L OFFICE COPY �2 (D)24"x12"CD ❑ b270 CFM (D)8•O 2O GRILLE, REGISTER AND DIFFUSER SCHEDULE - (E)22"0 ® (E)20"0 1 " ❑ — -- — _ SYMBOL DESCRIPTION MANUFACTURER&MODEL Z B 2 024k12'CD - (E)18"X10"CD( 'O^ _j 270 CFM 750 CFM TITUS MODEL TSMA ADJUSTABLE AIRFLOW W1 24"X24"CEILING PAN WI v) w } LCO LAY-IN CEILING DIFFUSER ' O -El (TYP OF 4) TYPE 3 BORDER FOR LAY-IN CEILING.FACTORY WHITE FINISH. aL Q D - — ^ �/ co Ww = � NEW TRANSFER FAN SCHEDULE � V rn DEMO MECHANICAL PLAN N ELECTRICAL � � 0 SYMBOL SERVES TYPE CFM ESP MOTOR HP CONTROL SONES WEIGHT MANUFACTURER & MODEL ePROEK� REMARKS Y U V/HZ/PH FLA QQ p ULDa � INNNNNNN 3: 1F CLICKLIST IN-LINE 250 0.250" 166W 120/60/1 2.1 CONTINUOUS 2.9 65 lbs. CAPTIVEAIRE CFA 250CA - (1) 1 11 � tnU � 1) TRANSFER FAN SHALL BE CONTRACTOR PROVIDED AND INSTALLED. CITY OF TIGARD,, 01 W M Lo REVIEWED FOR CODE cow)LIANCB V LID Approved:. ] 16 0 L VT.- 18 19 19. 20 orC: ( ] Permit #: mer 3gD QL I OLS �O UI Address: 6-C, PC Suite #: �-_.Date 250 CFM 235 CFM I (TYP OF 6) 10'0 L7 N ( •�'RG D1 = Z o (E)10'0 1,950 CFM I= NNN Q m € Ij a + --- EXISTING AC Z (E�14 N 31 4 C7 Z DD 1,950 CFM --- Z O 'L - J " � L3LL P — S (E)22"0( 11 IXISTING EXISTING LY o N 0 O RTF 1 PICK UP DFC 1 1 m N 12'X6 1 1 3,000 CFM D (E)16'0 _ --- (E)10'0 I REUSE OF DOCUMENTS u I T -- Qy r=AW This document, and the ideas and designs incorporated, as N (E)12"0 (E)10'0 ❑ m\ (R)AC 31 O E 30"X18"CDO an instrument of professional TF _ 24"x12'LTG 1 �ry �7 ( ) 12 FLORAL w �i 1000 CFM service is the property of 1 COOLER U Western Construction (TYP OF 3) 250 CFM ® � _ Services, Inc. a Corp. of WA and is not to be used, in whole or in part, for any E reason without the written authorization of Western 3 (N)12'0 12k12"STGO Construction Services, Inc. a 54 CFM EXISTING ❑ u Corp of WA. DFC 1 PCIODOLER 2 �� .A \ I ❑ (E)14'0DATE ISSUE 03.17.21 submittal (E)22"0 ® (E)20'0 ❑ - ---- (W-M-1001)J (E)18"X10'CD�t 540 CFM 750 CFM (TYP OF 4) ❑ ❑ ❑ MECHANICAL PLAN N DRAWN BY: TRB CHECKED BY: TSJ JOB # : 21-FMI-1014 ECI 93X04 SCALE: AS NOTED SHEET NUMBER M1 . 1