Loading...
Plans (12) M EC2021 -00107 DUCT FITTING SYMBOLS RECElv �u FIROFFS DOUBLE LINE SINGLE LINE DOUBLE LINE SINGLE LINE OUTSIDE AIR (VENTILATION) REQUIREMENTS MSCI-1ANICAL CODE NOTES FEB 9mi w'I �� NET VENTILATION REQ VENTILATION HVAC CONTROLS - CITY OF TIGARD ROOM AREA AREA OCCUPANCY * PEOPLE OSA RATE AREA OSA RATE TOTAL PROVIDED SYSTEM THERMOSTATS TO BE 7 DAY PROGRAMMABLE WITH NIGHT WILDING DIVISION oR oN Rf 5 LESS THAN 15' 502CONFERENCE 115 FT2 115 FT2 50 OCC/1000 FT2 = 5.75 5 CFM/OCC = 35.94 CFM 0.06 CFM/FT2 = 8.63 CFM 44.56 CFM 45 CFM _ SETBACK. MINIMUM DEADBAND FOR THERMOSTATS 5 DEGREE F. PER 6.4.3 OF ASHRAE STANDARD 90.1-2016 J+ 'y 15 Zp� LJ 5 PIECE ELBOW 503 CONFERENCE 92 FT2 92 FT2 50 OCC/1000 FT2 = 4.6 5 CFM/OCC = 28.75 CFM 0.06 CFM/FT2 = 6.9 CFM 35.65 CFM 35 CFM - C1 15'-30' "'y 5040PEN OFFICE 193 FT2 193 FT2 5 OCC/1000 FT2 = 0.97 5 CFM/OCC = 6.03 CFM 0.06 'CFM/FT2 = 14.48 CFM 20.51 CFM 74 CFM - CONTROLS TO VARY THE START-UP TIME OF EACH SYSTEM TO 00I W.W C� 11.32 OCCUPANT DIVERSITY = 0.97 AR DISTRIBUTION EFF. = 0.8 100.7 CFM 1 154 CFM** I MEET SPACE REQUIREMENTS PER 6.4.3.3.3 OF ASHRAE STANDARD I EXP DECEMBER 31, 2021 90.1-2016. R=W * PER ASHRAE 62.1-2010 TABLE 6-1 AND 2019 OMSC TABLE 403.3 RA %30' ** EXISTING SYSTEM ASSUMED TO BE DRAWING A MINIMUM OF 25% OUTSIDE DUCT SYSTEMS - REVISIONS: ELBALL DUCTWORK TO BE SEALED AND INSULATED PER 6.4.4.1.2 AND VARIABLE AIR VOLUME U N I T5 6.4.4.2.1 OF ASHRAE STANDARD 90.1-2016. RADIUS ELBOW DESIG MN MAX BOX NLET ELECTRIC MANUFACTURER WEIGHT 0&M MANUALS - RADIUSO1 o&M MANUALS TO BE PROVIDED TO BUILDING OWNER. TURNING ELBOW (RHD) CFM CFM SIZE PRESS FEAT & MODEL NUMBER LBS VANES OVER 30' VAV-1 150 1 600 8 0.5" 1 5 kW /2 STEP TRANE VCEF08 38 Z____r, ELEVATION ELEVATION MITER ELBOWFAN COIL UNIT SCHEDULE FROM ABOVE FROM ABOVE COOLING HEATING WEIGHT MANUFACTURER OFFSETS DESIG CFM MOTOR SPEED MBH MBH LBS AND MODEL NO. B f--�-S FC-1 435 38 W HIGH 10.9 13.5 22 DAIKIN FTX12AXVJU OFFICE COPY SUPPLY SUPPLY & 15'MAX�' ' 0111'0P'I'IGARD,. Scott 1A1 RETURN REVIEWED FOR CODE COMPLIANC$ Scott Y Y, Cruz 12" 30' 15'MAX�1 s-- 1 HEAT PUMP UNIT 5CHEDULE Ap �' � Engineer OTCl B • . 7510 N.E. VANCOUVER MALL OR SUITE 100 RETURN COOLNG FEATNG WEIGHT MANUFACTURER Permit#; VANCOUVER, WA. 98662 (360) 254-9234 f--�� DESIG SEER FISPF r7]ea3oA ►- 0 Q 1� RECTANGULAR TAP MBH 1 MBH 2 LBS AND MODEL N0. E-MAIEPARAL000OMCASrNEr 15'MAX t"o > "O Address: gl1c1� �J W1 �, TRANSITION HP-1 10.9 13.5 19.0 10.0 64 DAIKIN RX12AXVJU �3 Suite#t "B" IF TO DIFFUSER W1 OR GRILLE W1 TAT 78-F DB, 63-F WB ENT. COIL, 95'F OUTSIDE TEMPERATURE B Due + �2 AT 70-F DB INSIDE TEMPERATURE, 47-F OUTSIDE TEMPERATURE L TURNING W2 B v TURNING B� O3 MATCHED WITH FC-1 W1 VANES SUPPLY &W2,.H VANES SUPPLY & ` �l W2 RETURN RETURN - W2.il MITER ELBOW BRANCH Heating&Air Conditioning Inc. MITER TEE RECTANGULAR "Get it done the RITE WAY!" CCB 71242 HVAC SYMBOLS --- - INTERNALLY INSULATED SHEET METAL (SINGLE LINE) INTERNALLY INSULATED SHEET METAL (DOUBLE LINE) BARE OR INSULATED METAL DUCT (SINGLE LINE) BARE OR INSULATED METAL DUCT (DOUBLE LINE) 0 FLEX DUCT (SINGLE LINE) O ROUND DUCT: UP OR DOWN B BUTTERFLY DAMPER BDD BACK DRAFT DAMPER OBD OPPOSED BLADE DAMPER n OAD-1 OUTSIDE AIR DAMPER No.1 s 4 IS SO SMOKE DETECTOR T T THERMOSTAT: WALL MOUNTED S S SENSOR HSW HIGH SIDE WALL SUPPLY OR RETURN LSW LOW SIDE WALL SUPPLY OR RETURN ECG EGGCRATE GRILLE J Q [� RA RETURN AIR: UP OR DOWN [--------4 OSA OUTSIDE AIR: UP OR DOWN Z SA SUPPLY AIR: UP OR DOWN LLJ 110 AIR VOLUME, CFM C�l cc 8x8 DIFFUSER NECK SIZE 4W BLOW DIRECTIONS RB REBALANCE EXISTING DIFFUSER TO THIS CFM (30)- RELIEF AIR CFM THRU UNDERCUT OF DOOR AND FLOW DIRECTION W W VAV-1 VARIABLE AIR VOLUME NO. 1 24x24 24X24 RETURN O Z C CT TO EXISTING ONNEC ` C1 REMOVE TEMPORARY CAP & CONNECT T� �� TTLTFE ��� W Ix EXISTING TO REMAIN U rc O CAP EXISTING (J� TEMPORARILY CAP EXISTING O NEW z W LL C7 cc RELOCATE EXISTING Q Iq J ------------- t REMOVE EXISTING D_ rz W/ WITH ALL OTHER HVAC---' ULL N THESE AREAS Q Uj - NO CHANGES W J Z Q O V) HP-1 ON ROOF v CONTRACTOR TSO Q VERFY EXACT a OCATI INEO 20"0, CONFERENCE DATE ISSUED: 0 10X1D 503 v1 a FC 1 �� OPEN 502 NCE PLOT DATE: o�14E $. 8x8 8x8 n5 February 03, 2021 IZN MOUNT ON 8X8 CHECKED: 0 WALL QE 15x12 0 B N 4W S. Cruz 3 xi 02 0 O 8"0 UP DESIGNER: Sc "? CAD OPERATOR: SC No E 33x20 FO PARACLETEJOB. 21017 QE 20'0 N Ol 3 I PAPTIAL FIFTH FLOOR HVAC PLAN M CD MI 1/8" = f-Ow DRAWINGS DONE FOR N RITE WAY HEATING