Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
FPS2021 -00135 OFFICE COPY OFFICE COPX RECEIVED Nov 10 NZI PRIME CIN OF TIGARD T BUILDING DIVISION Project Name: Driveway Finance TI Standby Hours: 24 ELECTRICAL CEILING �F F� J Project ID: Suite 301 Alarm Mins:��J 6"MIN Prepared By: Oleg Primachenko Derating Factor: 1.2 SERVICES SK-5495 NAC Power Expander Date: 4/5/2021 Voltage Drop Warning 6"MIN 6"MIN 872395 30' MAXIMUM HEIGHT Threshold%: 20 POB F 8 F Vancouver, WA A 98687 (360)335-3565 Panel ID: NAC:03 Model: SK-5495 NAC Power Expander Max NAC Current: 3.0 Amps (36o)869-9989 fax F F Location: Electrical Room 3rd Floor Volts: 24 VDC Max Panel Current: 10 Amps CCB#217825 Current Draw Wire AWs @ G Ohms Per Length(ft) Actual Volt ° Ckt.# Circuit Name /°prop INRFMEENr CONFLI INS SI NEOAM Standby Alarm &Type 1000 Ft. One-Way Ohms EOL EerwEENTNEowcrNnl.slcN®nND 5495 NAC Expansion 1 1 0.075 0.205 1 SEALED DocrrslErrrs PREPARED BY ME ARCH rrECIS AND/OR THEIR CDNSULTAMS, FRCP OR FAA NAC#1 NPS3.01 cfg. 0.000 0.754 -14 Solid 2.52 194 0.98 19.66 3.61% AND ANYwPYOFTHEDoCUMEais TRANSMnTED BY MAIL,FAX, NAC#2 NPS3.02 cfg. 0.000 0.697 145o1id 2.52 260 1.31 19.49 4.48% ELECntONICALLY OR OTHERWISE,THE EXTENDER 96"MAX 96"MAX J ORIGINAL SIGNED AND SEALED DOCUMEMS NAC#3 NPS3.03 cfg. 0.000 0.854 +14 Solid J 2.52 274 1.38 19.22 5.78% Se LGOYERN. PANEL a 60" NAC#4 spare cfg. 0.000 0.000 a14 Solid J 2.52 0.00 20.40 0.00% APPROX. 90"MIN Aux cfg. 0.000 0.000 -14Sord J 2.52 0.00 20.40 0.00% 72" OU"MIN 80"MIN Total Standby Current(Amps) 0.075 2.510 Total Alarm Current(Amps) @CopyrightPrimeElectricalzozo BOTTOM BOTTOM OF LENS OF LENS Standby Time In Hours 24 1 0.083 1AIamn Time In Minutes /60 (5 Mins) This drnwingroats.inirrmdint atL 48"MAX property of PrimeneeNirslServir LW.Tw 42"MIN Total Standby AH Required 1.800 0.209 Total Alarm AH Required drawing inrnceiwdinm"fiik�and narnrn r mey ant be die l°rcd without priorewuentof TotalCombinedAHRequired 2.01 PrrneElectriewlService,UX,This drawing - Multiply By The Derating Factor 1,20 " shad sot be used for mmpetlBre bid pwm . € Minimum Battery AmpHours Required 2.41 FINISHED FLOOR ' PRIME JOB# NAC CIRCUITS CALCULATION PROJECT# B TYP. FIRE ALARM DEVICE MOUNTING o DATE: SCALE: NONE F 1 . 1 SCALE: NONE REVISIONS ABBREVIATIONS LEGEND _� OFFICE COPY EOLR END OF LINE RESISTOR MY OF TTGARI REVIBWBD FOR CODE COMPLIANCE #6270S EOL END OF LINE ApprimedL -*/ I CD CANDELLA N „a OTC1 DH DOOR HOLDER F PLEASE PRO DE tRnNE � Pe"remit�: PS.1c�-11- C,>CUU�, 13 COMPLETED NF A 72 WP WEATHERPROOF CONFERENCE Address: &!_0_LL ) .4 !bZ--� RECORD F2057 Suite#�: Sp COMPLETIO AT (D) EXISTING TO BE DEMOLISHED/REMOVED . gyr; Date: I� -1. -�1 FINAL INSPECTION (E) EXISTING TO REMAIN N (RL) EXISTING TO BE RELOCATED (RP) EXISTING TO BE REPLACED OPEN OFFICE 203 VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT (N) NEW OFFICE N i17 F BREAK BASED ON CONSTRUCTION 206 F 'NP�saoe 202 DOCUMENTS AND OTHER nsm ♦G (NIC) NOT IN CONTRACT NP$100 DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM (N/A) NOT APPLICABLE REQUIRING THE CORRECTION O OF ERRORS. OSSC 105.4 ' ^ z OFFICE u .► FIRE ALARM WIRE SCHEDULE 207 0E, El N O P4 SYMBOL DESCRIPTION WIRE SIZE/TYPE LOBBY W 4-1 Cz Q� S SLC LOOP or INITIATION CIRCUIT 18/2 FPLR 201 N NOTIFICATION APPLIANCE CIRCUIT 14/2 FPLR CONFERENCE N co 17, F ANNUNCIATOR CIRCUIT 18/4 FPLR NP " "x'01 E"'� N P AUXILIARY POWER CIRCUIT 16/2 FPLR �^ �1 OFFICE W 0 _209 4TH FLOOR �1 PL PLANUM RATING DESIGNATION _--- FPLP WELLNS. IT 3RD FLOOR ^ COPY 214 215 115 30 75 15 75 15 15 15 30 30 75 15 FIRE ALARM SYMBOLS LEGEND NPS 213 "P 103 `z Cz land F F F F F F F F F F F F OFFICE NPs a-0a 210 SYM DESCRIPTION MODEL# BACK BOX 210 . 4,7K 75 75 95 15 15 15 15 15 30 FACT FIRE ALARM CONTROL PANEL EXISTING 2Q� "Ps4,7K F F F F F F F F F NPS.1-02 PS. NAC EXPANSION PANEL EXISTING ----- V�1 75 30 30 30 30 15 15 15 15 115 FA-AM REMOTE ANNUNCIATOR PANEL ----- -____ OFFICE _-211- NIPS 3-01 F F F F F F F F F F NPS:3-01 O DIAL DILER COMMUNICATOR ----- ----- �T^~�T � hal CN © SPRINKLER FLOW SWITCH ----- ----- W © SPRINKLER TAMPER SWITCH ----- ----- �'I OFFICE OPEN OFFICE NPs:3 212 � 216 .i Q ADDR. MONITOR MODULE ----- 4X4 STANDARD ELEC.BOX 4.7K ELR N °`""�""°^ NPS J Z4 Tie-in to Existing Q ADDR. MANUAL PULL STATION ----- 1-GANG STANDARD ELEC.BOX F Fire Alarm Loop NPS:S ® ADDRESSABLE RELAY ----- 4X4 STANDARD ELEC.BOX @(E) 120VAc 2N • ® MAGNETIC DOOR HOLDER ------ 4X4 3.5" DEEP ELEC.BOX DRAWN-BY: DATE: DUCT SMOKE DETECTOR ----- 4x4 STANDARD ELEC.BOX 3RD FLOOR Ll/3/zort 2ND FLOOR DESIGNED-BY: NED-BY: DATE: Q PHOTO SMOKE SENSOR W/BASE ----- 4" OCTAGON ELEC.BOX OP 11/3/2021 95 15 15 115 15 75 is 15 15 QH HEAT DETECTOR W/BASE ----- 4" OCTAGON ELEC.BOX NPS.3-04 F F F F F F F F F NPS.1-04 DRAWING y�, 4.7K CEILING HORN/STROBE UNIT PC2WL 4" OCTAGON ELEC.BOX F CEILING STROBE UNIT SCWL 4" OCTAGON ELEC.BOX Floor Plan WALL HORN/STROBE UNIT P2RL 1-GANG STANDARD ELEC.BOX ~ - ' - SHEET F WALL STROBE UNIT SRL 1-GANG STANDARD ELEC.BOX SPRINKLER FIRE ALARM BELL ----- 1-GANG STANDARD ELEC.BOX FIRE ALARM PLAN LAYOUT RISER DIAGRAM Fiel JUNCTION BOX ----- 4x4 STANDARD ELEC.BOX F "' 1 SCALE: 1/8" =1r-0" 1/8"=1'-0" F 1 . 1 SCALE: NONE 0 5' 10' 15' FILE: FA1 PLANS.DWG - EMBASSY STE 250 BY: OP PLOT: 11/8/2021 12:56 PM