Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
BUP2022 -00042 OFFICE COQ' OFFICE COPY RECEIVED FEB 0 7 2022 CITY OF TIGARD BUILDING DIVISION L f HEALTHY LIVING T . I ARCH I T E C T S 720 NW Davis 503.221.1121 11� Suite 300 503 221.2077 D Portland OR 97209 www.irsarchitects.com 16083 SW UPPER BOONES FERRY RD SUITE 310 & 330 , TIGARD , OR 97224 PERMIT SET - 02 . 07 . 22 it PROJECT DIRECTORY CODE SUMMARY BIDDER DESIGN NOTES OWNER REPRESENTATIVE: 1. PROJECT INFORMATION: GENERAL SC Labs I Oregon Q Q VQ EasyPowerQ, a y PARKLAND DEVELOPMENT, LLC CONTACT PERSON PROJECT NAME: Fanno Creek Bldg. B 1. WARRANTY ALL PARTS, LABOR, EQUIPMENT, AND MATERIAL PROVIDED UNDER THIS PROJECT ADDRESS: 16083 SW Upper Boones Ferry Rd. CONTRACT OF A PERIOD OF ONE YEAR, UPON FINAL COMPLETION OF CONTRACT. Peter's Auto Works 16083 SW UPPER BOONES FERRY RD. SUITE 120, SEJIN KIM SUITE 310 & 330 Chemwest Systems Inc Tigard, OR 97224 2. OBTAIN AND PAY FOR ALL PERMITS AND FEES TO COMPLETE THE WORK. OBTAIN TIGARD, OR 97224 sejin@pldus.com 9 AND PAY FOR ADDITIONAL DRAWINGSAND SPECIFICATIONS REQUIRED FOR Q HairClub Q www.pldus.com MAP/TAX LOT: 2S113AB00500 PERMITS. Anim BUILDING TYPE: II-13 ; T:503.639.0108 ext.100 BUILDING OCCUPANCY: B 3. GC TO COORDINATE WITH ALL SUBS ON CODE REQUIRED ACCESS PANELS IN Northwes%Mothers a o AREA OF WORK: +/-2,929 R.S. F. (SUITE 310) +/-1,104 RSF (SUITE 330) CEILINGS AND WALLS, ALL NEW ACCESS PANELS TO HAVE DOOR FACED RECESSED Mill Bank a Or on State Bar z O76 PROJECT DESCRIPTION: INTERIOR TENANT IMPROVEMENT- INCLUDING DIVIDING FOR GYPSUM BOARD INFILL WITH CONCEALED FLANGE FOR GYPSUM BOARD y Q LL CONSULTANT: ARCHITECT: EXISTING SUITE INTO 2 SEPARATE SUITES. MINOR DEMO AND INSTALLATION, CONCEALED HINGES AND PUSH TO RELEASE LATCH. y LRS ARCHITECTS CONTACT PERSON NEW CASEWORK WITH SINK. 4. GC TO VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO Columbia Gunsmithing TAP Plastics D SITE LOCATION 720 NW DAVIS, STE 300 PETER KIM ARCHITECT. un shop mo Il.JURISDICTIONAL CODES: / e` PORTLAND,OR 97209 pkim@Irsarchitects.com 2018 INTERNATIONAL BUILDING CODE (IBC) / J www.lrsarchitects.com 2019 OREGON STRUCTURAL SPECIALTY CODE (OSSC) 1016083S 5y� 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) ELECTRICAL-BIDDER DESIGN ewnW T:503.221.1121 5. ELECTRICAL SYSTEM AND REQUIREMENTS ARE BIDDER DESIGN. LIGHTS AND rp erry d._ 2019 OREGON MECHANICAL SPECIALTY CODE(GMSC) n 2018 INTERNATIONAL FIRE CODE ELECTRICAL INFORMATION ON DRAWINGS IS PROVIDED FOR REFERENCE ONLY yyC' GENERAL CONTRACTOR: 2019 OREGON ZERO ENERGY READY COMMERCIAL CODE(OZERCC) AND IS INTENDED TO SHOW FIXTURE TYPES AND DESIGN INTENT. ES Commercial Kiddie Academy ��'a 2017 OREGON PLUMBING SPECIALTY CODE(OPSC) 6. SUBMIT ELECTRICAL DESIGN TO ARCHITECT FOR COORDINATION. ELECTRICAL of Tigard te` Air Filters Northwest,Inc BUILT ENVIRONMENT NW CONTACT PERSON 2017 OREGON ELECTRICAL SPECIALTY CODE(OESC) PLANS TO INCLUDE LOCATIONS FOR ALL LIGHTING, EMERGENCY LIGHTING,AND Q d ey 135 E HEREFORD ST., ROMAN MICHALCHUK 2009 ICC-ANSI Al 17.1 FIRE-LIFE SAFETY FIXTURES. SUBMITTAL TO INCLUDE PROJECTS CUTSHEETS AND The Circuit Bouldering r o°c f PHOTOMETRIC CALCULATIONS. ELECTRICAL DESIGN MUST BE APPROVED BY OWNER ,41 Gym T1 ard �� N O OFFICE COPY GLADSTONE,OR 97027 roman@be-nw.com C7 iL AMSOIL III.ADA ACCESSIBILITY UPGRADES AND ARCHITECT PRIOR TO CONSTRUCTION. JQ a www.builtenvironmentsnw.com 1� 9 DistributionCenter , CMOpTIGa,�� 1. BUILDING HAS BEEN UPGRADED ACCORDING TO IEBC 301.5, OSSC CHAPTER 11 AND ICC 7. COMPLY WITH ALL JURISDICTIONAL ENERGY CODES AND PROVIDE ENERGY `' Aulon Ce t er `•+�� T:503.650.4086 ANSI Al 17.1-2009. Allstructure Engineering CALCULATIONS IF REQUIRED. FOR CODS CONpLLrAr}= VI. EMERGENCY SYSTEM STANDARDS: 8. COORDINATE ELECTRICAL REQUIREMENT FOR MECHANICAL SYSTEMS AND PROVIDE ® 9Service Partners AppO� AS NECESSARY. irgasStoree ®Ore on State + 1. IF BUILDING IS FULLY SPRINKLERED (NFPA 13). MAKE CODE MINIMUM CORRECTIONS AS 9. IF AN OVERRIDE SYSTEM EXISTS, PROVIDE EACH TENANT SPACE WITH AN 9 s PphrSi 9 Treasury 0TQ� i REQUIRED PER NEW PLAN. OVERRIDE SWITCH FOR FULL- SERVICE BUILDINGS. � DRAWING INDEX 2. IN BUILDINGS WITH EXISTING SMOKE DETECTORS: PROVIDE CODE MINIMUM 10. SWITCHING FOR LIGHTING IS INDICATED IN THE DRAWING FOR REFERENCE ONLY (141 u Miratron . iL1.rZst CORRECTIONS AS REQUIRED. SMOKE DETECTORS TO BE TIED TO THE BUILDING ALARM AND IS INTENDED TO ONLY SHOW SWITCH LOCATIONS, REQUIREMENTS FOR DUAL Option Care at© f O Stout Ti N \/ SHEET NUMBER SHEET NAME SYSTEM. SWITCHING, AUTOMATIC AREA SHUT OFF CONTROLS AND ALL OTHER CODE 9 Lenacv Heatth y n„� a 3� 3. IN BUILDINGS EQUIPPED WITH AN EXISTING VISUAL STROBE SYSTEM: PROVIDE CODE REQUIREMENTS SHALL BE THE RESPONSIBILITY OF THE BIDDER DESIGN CS COVER SHEET MINIMUM CORRECTIONS AS REQUIRED. IF A SYSTEM DOES NOT EXIST, DO NOT ADD CONTRACTOR. PROVIDE A MINIMUM OF ONE SWITCH PER ROOM, UNLESS VI CINI TY MAP A110 CODE ANALYSIS PLAN ONE. OTHERWISE INDICATED.4. PROVIDE EMERGENCY SYSTEM LIGHTING WITH NO LESS THAN 1 FOOT-CANDLE AT THE 11. WHEN NEW LIGHT SWITCHES ARE ADDED TO ANY PORTION OF THE SUITE, SCALE: NOT TO SCALE A111 ACCESSIBILITY COMPLIANCE FLOOR LEVEL ALONG ENTIRE EGRESS PATH PER CURRENT NATIONAL ELECTRICAL REPLACE ALL EXISTING LIGHT SWITCHES WITH NEW OCCUPANCY SENSOR A201 CONSTRUCTION PLANS& FINISH INFO CODE REQUIREMENT. SWITCHES. A01 REFLECTED CEILING PLAN & HEADER DETAILS 5. PROVIDE EXIT SIGNAGE. EXIT SIGNAGE SHALL BE CONNECTED TO BUILDING POWER 12. PROVIDE ILLUMINATED EXIT SIGNS AT REQUIRED EXIT DOORWAYS AND WHERE TRUE NORTH A8801 ELEVATIONS & DETAILS SUPPLY WITH BATTERY BACK-UP FOR MIN 1-1/2 HOUR DURATION. EVERY 1 00' IN NECESSARY TO INDICATE THE DIRECTION OF EGRESS WHEN THE EXIT SERVES AN CORRIDORS, AND IN SPACES WHERE 2 MEAN OF EGRESS ARE REQUIRED PER SECTION OCCUPANCY LOAD OF FIFTY OR MORE. 1013. SEE ELECTRICAL DRAWINGS. (W/POCHE INDICATING"EXIT"TEXT SIDE OF SIGN) 13. PROVIDE VISUAL AND AUDIBLE ALARM SIGNAL APPLIANCES INTEGRATED INTO THE SIGNS SHOWN IN CORRIDORS ARE CEILING HUNG. SIGNS SHOWN ON WALL ARE WALL BUILDING ALARM SYSTEM AS REQUIRED BY CURRENT JURISDICTION CODES AND HUNG. REQUIREMENTS. PROVIDE ADDITIONAL ELECTRICAL SERVICE AS REQUIRED. iIrthwest Mothers 6. PROVIDE CODE MINIMUM FIRE ALARM CONNECTIONS AS REQUIRED. COORDINATE REQUIREMENTS WITH BUILDING OWNER.ALARM LOCATIONS 16083 SW UPPER BOONES FERRY RD 7. SURVEY EXISTING CONDITIONS OF ENTIRE FLOOR THAT PROJECT OCCURS,AND INDICATED ON PLANS ARE ONLY FOR REFERENCE. PROJECT NUMBER: 222008 PROVIDE NOT LESS THAN ONE APPROVED FIRE EXTINGUISHER WITH RATING OF NOT 14. PROVIDE SHOP DRAWINGS FOR ALARM SYSTEM LAYOUT AS REQUIRED BY CODE. • LESS THAN 2A 10B/C FOR EACH 1,500 S.F. OF FLOOR AREA OR FRACTION THEREOF. 15. VERIFY SERVICEABILITY AND REUSABILITY OF EXISTING ELECTRICAL EQUIPMENT,AND UNDER SEPARATE PERMIT TRAVEL DISTANCE TO AN EXTINGUISHER FROM ANY PORTION OF THE BUILDING SHALL • REPAIR OR REPLACE AS NECESSARY. NOT EXCEED 75 FEET. PROVIDE FIRE EXTINGUISHER I ACCORDANCE WITH CURRENT 16. VERIFY THE CAPACITY AND REUSABILITY OF EXISTING ELECTRICAL PANELS TO • • • - Healthy Living T.I. CODES. PROVIDE NEW FIRE EXTINGUISHER AT ALL EXISTING CABINETS WHERE MEET PROJECT REQUIREMENTS. 'Alt �y ELECTRICAL SYSTEMS,MECHANICAL INCLUDING EGRESS LIGHTING RECHARGED,AS NECESSARY, UST PRIOR MISSING. ALL REUSED EXISTING FIRE TO SUBSTANTIAL COMPNGUISHERS ARE TO BE LETION. AND/OR 17 KNOWN EXISTING ELECTRICAL AND PHONE/DATA OUTLETS HAVE BEEN INDICATED ON ii THE DRAWING.ADDITIONAL EXISTING OUTLETS MAY EXIST AND SHOULD BE f` Fanno Creek Place PLUMBING SYSTEMS 8. CONTACT OWNERS REPRESENTATIVE FOR INSTRUCTIONS WHEN SCHEDULING WORKR. • ,,/ ON FIRE SPRINKLER&ALARM SYSTEMS VERIFIED BY 18. SMOKE DETECTIONTIE DEVICES INDICATED ON THE DRAWING ARE FOR REFERENCE Q Boones - I�� • Bldg. B ONLY. CONFIRM SPACING OF DETECTORS WITH DEVICE LISTING. 19. CLEAN AND REPAIR EXISTING SMOKE DETECTORS TO BE REUSED TO GOOD WORKING CONDITION. 16083 SW Upper Boones GENERAL NOTES QC /SUBMITTAL REQUIREMENTS 20. CLEAN NEW, EXISTING, AND RELOCATED LIGHT FIXTURES IN PROJECT AREA, OR IN FerryRd. Suite 310 & 330 AREAS AFFECTED BY WORK OF THIS PROJECT,AT COMPLETION OF JOB. RELAMP 1. THE GENERAL NOTES ARE INTENDED TO CONVEY DESIGN INTENT 1. SUBMIT SUBSTITUTION REQUESTS ON CSI FORM TO ARCHITECT FOR APPROVAL. AND REPLACE BALLAST IN LIGHT FIXTURES AS REQUIRED TO RESTORE TO Tigard, OR 97224 NOT OTHERWISE STATED IN THE DRAWINGS. ARCHITECTS DECISION IS FINAL WHETHER OR NOT A PROPOSED PRODUCT IS WORKING ORDER. g 2. ALL WORK SHALL CONFORM TO THE CODES REFERENCED IN THE ACCEPTABLE FOR SUBSTITUTION. 21. CLEAN AND REPAIR EXISTING EXIT SIGNS TO BE REUSED. REPLACE BATTERY AND/ PROJECT SUMMARY AND TO CONDITIONS AND SPECIFICATIONS OF 2. APPLICATION OF MATERIALS TO SURFACES EXISTING OR PROVIDED UNDER THIS OR BALLAST IF NOT IN GOOD WORKING CONDITION. - ALL GOVERNING AUTHORITIES. CONTRACT IMPLIES ACCEPTANCE AND SUITABILITY OF EXISTING CONDITIONS. 22. COORDINATE TELECOMMUNICATIONS AND MODIFICATION TO BUILDING ALARM 3. THE SITE PLAN AND SUITE LOCATION PLAN ARE FOR REFERENCE 3. ALL MATERIALS AND PRODUCTS USED ON THE JOB SITE SHALL BE"ENVIRONMENTALLY SYSTEM PROVIDED BY TENANT. VERIFY WITH TENANT LOCATION OF NEW OUTLETS ONLY. SEE ALL OTHER SHEET PLANS FOR CONTRACT DOCUMENT SAFE LOW ODOR,AND NON FLAMMABLE. USE OF ANY PRODUCT NOT COMPLYING WITH PRIOR TO INSTALLATION. INFORMATION. THE CODE SUMMARY IDENTIFIES SOME THIS CRITERIA MUST BE APPROVED BY THE BUILDING OWNER AND/OR ARCHITECT. 23. REMOVE ALL UNUSED OR ABANDONED ELECTRICAL WIRING, EQUIPMENT, AND V JURISDICTIONAL REQUIREMENTS BUT IS NOT INTENDED TO LIST 4. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY DAMAGE OR CLEANING PHONE AND DATA CABLING. CONFIRM WITH OWNER PRIOR TO REMOVAL. ALL ALL REQUIREMENTS. THROUGHOUT STRUCTURE DEEMED TO BE A RESULT OF HIS/HER WORK. THOROUGHLY WIRING AND CABLING TO REMAIN SHALL BE SUSPENDED FROM STRUCTURE AS N 4. ALL WORK INDICATED ON DRAWINGS SHOULD BE CONSIDERED CLEAN PREMISES UPON COMPLETION OF WORK, INCLUDING WASHING OF WINDOWS, REQUIRED BY CURRENT CODE. NEW AND IN CONTRACT UNLESS NOTED OTHERWISE. SO THAT BUILDING IS READY FOR OCCUPANCY BY TENANT. INCLUDE CLEANING OF ADJACENT AREAS WITHIN AND AROUND THE BUILDING THAT ARE NOT PART OF TENANT SITE PLAN IMPROVEMENTS, BUT WERE AFFECTED BY TENANT IMPROVEMENT CONSTRUCTION VALIDITY OF PERMIT OPERATIONS. REPAIR/REFINISH ANY DAMAGE TO EXISTING FINISH SURFACES. SCALE:NOT TO SCALE THE ISSUANCE OF A PERMIT 5. PROVIDE THE FOLLOWING SUBMITTALS FOR THE ARCHITECT TO REVIEW PRIOR TO BASED ON CONSTRUCTION CONSTRUCTION:MECHANICAL PLANS(INCLUDING ZONE MAP), ELECTRICAL PLANS w (INCLUDING LIGHTING, CONTROLS AND PHOTOMETRICS), PLUMBING PLANS&FIXTURE TRUE NORTH DOCUMENTS AND OTHER i CUTSHEETS, PAINT DRAWDOWNS, FINISH SAMPLES, CASEWORK SHOP DRAWINGS, FIRE DATA SHALL NOT PREVENT LIFE SAFETY PLANS,APPLIANCES& EQUIPMENT AND DOORS, FRAMES, GRAZING & THE CODE OFFICIAL FROM o HARDWARE. REQUIRING THE CORRECTION 6. CASEWORK SHOULD ADHERE TO NORTH AMERICAN ARCHITECTURAL WOODWORK OF ERRORS. OSSC 105.4 STANDARDS 3.1 2017"CUSTOM" GRADE LINO. 7. INTERIOR WALLS TO BE LEVEL 4 SMOOTH FINISH IN ALL AREAS, UNO. AREA OF WORK N B. FLOORING DIRECTION AND SEAMING LOCATIONS ARE TO BE APPROVED BY THE SHEET TITLE: ARCHITECT. /� a' 9. PROVIDE FINISH MATERIALS MATCHING ESTABLISHED BUILDING STANDARD QUALITY, COVER SHEET 8 UNLESS OTHERWISE INDICATED. PROVIDE COLORS APPROVED BY OWNER AND d ARCHITECT. E 10.CONTRACTOR TO FILL AND PATCH EXISTING CONCRETE SLABS AND SHALL PROVIDE o SMOOTH UNIFORM SURFACE PRIOR TO NEW FLOOR COVERINGS TO BE INSTALLED. IN S AREA WHERE FLOOR IS TO BE LEFT EXPOSED, FLOOR TO BE MADE SUITABLE FOR SPECIFIED FINISH LEVEL s T S m m DRAWN BY: GV 8 DATE ISSUED: a v v U 0 PERMIT SET 02.07.22 LL O O N N N N ryO b 3 z � N AREA OF WORK SHEET: CS LRS Architects,Inc.0 2022 N SCALE: NOT TO SCALE TRUE NORTH PLAN NORTH CODE SUMMARY Lf (SEE EGRESS PLAN BELOW) A R C H I T E C T S REQUIRED EXITS PER SECTION 1006 (OCCUPANT LOAD PER SECTION 1004) 720 NW Davis 503.221.1121 1R OCCUPANCY SPRINKLERED OCCUPANT LOAD REQUIRED PROPOSED Suite 300 503 221.2077 0 LEVEL 3 Portland OR 97209 www.Irsarchitects.com B(SUITE 310) Y 39 1 1 B(SUITE 330) Y 17 1 1 EXIT ACCESS TRAVEL DISTANCE FROM MOST REMOTE POINT PER TABLE 1017.2 /Y OCCUPANCY SPRINKLERED REQUIRED PROPOSED LEVEL 3 ,I MpB1F SWRT B(SUITE 310) Y 300'MAX 89'4" /J B(SUITE 330) Y 300'MAX 41'-6" OF CONSULTANT: EGRESS PLAN LEGEND - NOT INCLUDED IN SCOPE OF WORK FEC SEMI-RECESSED FIRE EXTINGUISHER CABINET(EXACT LOCATION TO BE tDETERMINED BY FIRE MARSHALL) ' OCCUPANCY OCCUPANCYGROUP B Sr0JAS X OCC ROOM OCCUPANT LOAD PER PROJECT NUMBER: 222008 OCCUPANCY OFFICE SECTION 1004 (SUITE 330) ) Q EXIT SIGN W/INTEGRATED Healthy Living T.I. E DIRECTIONAL ARROW. PROVIDE AT ALL OFFI / 00 1 PER SECTION 1011 N SPACES WHERE 2 338 SF @ 1:15= �� / OR MORE ARE REQUIRED, SEE Fanno Creek Place „23 Ooc �F�1 //i/ a Bldg. B ELECTRICAL DRAWINGS. p V/ START ♦ — — ♦ EGRESS PATH (44"WIDE, UNO) 809 SF @ 1:150E F EJ BREAK END 16083 SW Upper Boones �V16 4 Occ EN7RY ROOM E♦ REQUIRED EXIT EGRESS 316 330 E ��� ,sz SF @ ,:,5= Ferry Rd. Suite 310 & 330 OFF�J 13 OCC Tigard, OR 97224 318 // (39) 041 / / / ) 317 // SUREEN4 / FE I OCCUPANCY OFFIR (SUITE 310) 316 \ 2,299 SF @ 1:150= \\ ■ 16 Occ OFF S \ r= T— r- I' ff� ). i \\ � EN OFFK'E N \\ � \\,/z 314 SHEET TITLE: CODE ANALYSIS 1 y 0473 T- - (N)COgfREF�E 1312 PLAN -�- l 5 3F m DRAWN BY: GV m DATE ISSUED: a U 0 N PERMIT SET 02.07.22 LL 00 O N 1. LEVEL 3 EGRESS PLAN Z SCALE: 1116= 1'-0" 0 6 r TRUE NORTH PLAN NORTH SHEET: A110 a E� LRS Architects,Inc.®2022 N M N TYPE OF USE MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS 5-0"MIN 5'-0"MIN_ GENERAL NOTES PARALLEL TO DOORWAY APPROACH DIRECTION DOOR SIDE PERPENDICULAR TO DOORWAY z (BEYOND LATCH UNLESS NOTED) � �� - � 2 � 1 g = _ ALL DIMENSIONS INDICATED ON THIS SHEET ARE z 2 FROM FRONT PULL 60" 18" 1 v � piluv CLEAR MINIMUM TO FACE OF FINISH. � � � N 1 2. ALL ITEMS INDICATED BELOW MAY NOT OCCUR ON L f FROM FRONT PUSH 48" 0" s z PROJECT,I HIS FROM HINGE SIDE PULL 60" 36" 3. SEE ARCHITECTURAL PLANS FOR ACCESSIBILITY AND �� � � CONFORMANCE IN THE HORIZONTAL PLAN LAYOUT. 0 FROM HINGE SIDE PULL 54" 42" --- N 4. SEE ARCHITECTURAL INTERIOR ELEVATIONS FOR ARCHITECT S -- - _— BEVELED CHANGE IN BEVELED CHANGE IN VERTICAL CHANGE IN CARPET PILE ACCESSIBLE MOUNTING. FROM HINGE SIDE PUSH 42" 1 22" 384 3'-0"MIN LEVEL(b) LEVEL(a) LEVEL HEIGHT 5. VERIFY ACCESSORY SIZE WITH MANUFACTURER TO 720 NW Davis 503.221.1121 11� 1'-0"MIN 1'4'MIN ENSURE CONFORMANCE WITH REQUIRED MOUNTING FROM LATCH SIDE PULL 48" 1 24" HEIGHTS. Suite 300 503 221.2077 C - _- - a CIRCULAR 6. PROVIDE CODE-COMPLIANT BLOCKING WITHIN WALLS FROM LATCH SIDE PUSH 42" 2 24" Portland OR 97209 www.lrsarchitects.com NOTE: IT IS RECOMMENDED THAT TOLERANCES BE BUILT INTO THE AS REQUIRED FOR PROPOSED AND FUTURE 'ADD 61NCHES IF CLOSER AND LATCH PROVIDED. DESIGN FOR ALL CRITICAL DIMENSIONS TO AID IN CONSTRUCTIBILITY ACCESSORIES AND GRAB BARS MOUNTING FIXTURES. 2 ADD 7 WALLS DESIGNATED ED ON FLOOR PLANS AS FIREE GYPSUM BOARD WRAP BEHIND AT 3ADD 62 INCHEINCHES S BEYOND LATCH IDF CLOSER AND LATCHED PROVIDED. B TURNING SPACE C FLOOR SURFACES & CHANGES IN LEVEL a �jy 4 BEYOND HINGE SIDE RESISTIVE. 8. ACCESSIBLE FIXTURES REQUIRE A CLEAR FLOOR SPACE A MANEUVERING CLEARANCES AT MANUAL ACCESSIBLE ROUOTE US OR OVERLAPPING THE FLOOR DRAINS SHOU SWINGING DOORS 20"MAX >20"-25"MAX 9 CLEAR FLOOR SPACELD NOT BE PLACED IN THIS MMIFIL SM A. EXCEPTION: DRAINS MAY RESIDE IN CLEAR FLOOR SPACE PROVIDED DRAIN HOLES DO NOT CL OF CL OF EXCEED 1/2" DIA. MAXIMUM; FLOOR SLOPE DOES on FIXTURE FIXTURE 4"MAX NOT EXCEED 2% IN ANY DIRECTION;AND THE z - ELEVATION CHANGE AT THE DRAIN LIP DOES NOT v g \ EXCEED 1/8' --- I --- z 4 � io � \ \� � 10. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, ? -- - PINCHING, OR TWISTING OF THE WRIST. THE FORCE o MM�� ' z 6 REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE OBSTRUCTED UNOBSTRUCTED 17"-25 48' IN 0 o HIGH FORWARD REACH FORWARD REACH 5.0 POUNDS MAXIMUM. n z z 11. ALL REQUIRED ACCESSIBLE FIXTURES AND qmo --- -- - ELEVATION PLAN ELEMENTS TO BE INSTALLED PER THE FIXTURE CONSULTANT: 8MIN T : CLEARANCE MOUNTING DIAGRAM AND PER ALL APPLICABLE 30"MIN z ACCESSIBILITY STANDARDS. SIZE OF CLEAR (b) PARALLEL (a) FORWARD FLOOR SPACE g n Z N X z POSITION OF CLEAR \ \ ' N FLOOR SPACE VERTICAL CLEARANCE LIMITS OF PROTRUDING OBJECTS N 11 MIN ' 2'-1"MAX 10"MAX >10"-24"MAX 10"MAX EXCEPTIONS: _J71. HANDRAILS SHALL BE PERMITTED TO PROTRUDE 4'/z'MAX. ELEVATION PLAN N OBSTRUCTED UNOBSTRUCTED 2. DOOR CLOSERS AND DOORSTOPS SHALL BE PERMITTED TO BE 78"MIN ABOVE THE FINISH FLOOR X ML A HIGH SIDE REACH SIDE REACH OR GROUND. KNEE CLEARANCE X o D REACH RANGES E PROTRUDING OBJECTS J KNEE & TOE CLEARANCE 60"MIN 36"MIN (b) PARALLEL (a) FORWARD APPROACH APPROACH MANEUVERING CLEARANCE IN AN ALCOVE G CLEAR FLOOR SPACE ALIGN ADJACENT OUTLETS SWITCHES O J Q U O, c� I c3j L+, PROJECT NUMBER: 222008 Lu vN �_W 2 _ OOO20 Lu X W U U U O 0 W U m vU� W O wW 4 � 4 h oz U) Co0 O � 0 oOs Health Living TI R Rp Z a a � p O p auo 0 a z vO _2 Fanno Creek Place MOUNTED INTERCOM ANNUNCIATOR EMERGENCY CIRCUIT PANEL MAILBOXES CALL BOX/ ELECTRICAL ELECTRICAL OUTLET WALL FIRE FIRE ALARM FIRE ALARM THERMOSTAT CLOSET SHELF Bldg. B PHONE STATION PANEL POWER OFF DOOR ACCES OUTLETS/WALL @ 34" H COUNTER MOUNTED FIRE EXTINGUISHER PULL STATION STROBE LIGHT (ENVIRONMENTAL AND ROD PUSH BUTTON SWITCHES EXTINGUISHER CABINET CONTROL) 16083 SW Upper Boones K GENERAL FIXTURE MOUNTING HEIGHTS Ferry Rd. Suite 310 & 330 Tigard, OR 97224 30"MIN WORK113OMIN 4' i Z-0" SURFACE CLR WIDTH PROVIDE PIPE PROTECTION UNDER SINK z -- m U DW w FREF a 0 0 y w w U U Q Q WORK SINK W/KNEE DISHWASHER REFRIGERATOR o SURFACE CLEARANCE SHEET TITLE: 'PROVIDE FLOORING& FINISHED WALLS UNDER 3 FORWARD APPROACH COUNTERS. ACCESSIBILITY "PARALLEL APPROACH ALLOWED AT SINK WHERE A COOKTOP/ NGE IS E L STAFF ROOM CLEARANCES *COUNTERTOP WORK SU FACE TOO BE 304 IA.F.F. MAX. COMPLIANCE a 0 0 0 0 r rn c 5 m v x m m DRAWN BY: GV 6 DATE ISSUED: a U 0 PERMIT SET 02.07.22 LL b N N 'J N ryO b N L 6 A111 `o 2 SHEET: P N E LRS AXhilwfs,Inc.®2022 Q N Lf GENERAL NOTES A R C H I T E C T S 720 NW Davis 503.221.1121 1Y A. THIS DRAWING DEPICTS EXISTING CONDITIONS FOR REFERENCE Suite 300 503 221.2077 D ONLY. VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK AND REPORT ALL DISCREPANCIES TO ARCHITECT. Portland OR 97209 www.lrsarchitects.com B. CEILING CONFIGURATION TO REMAIN, UNO. lei C. REPLACE ALL DAMAGED CEILING TILES &GRID TO MATCH EXISTING. ' KEYNOTES wrr'�' O PROVIDE MATCHING CEILING TILES WHERE MISSING. • • ppm O REMOVE EXISTING EXIT SIGN. O NEW BOX BEAM HEADER-SEE DETAILS 2-6/A401 FOR MORE DETAILS. OF LIGHTING LEGEND • 9'-9" CONSULTANT: EXISTING BUILDING STANDARD LIGHT FIXTURE D 3 2 • RCP LEGEND • - EXISTING 2x4 ACOUSTICAL SUSPENDED CEILING P-1 CEILING FINISH 1 • #10 SCREW AT 24"O.C. • EACH LEG TYPICAL EXISTING HVAC SUPPLY EXISTING HVAC RETURN BOTTOM TRACK MN • 1 N • ® ®+ EXIT SIGNS(W/INTEGRAL ARROW WHERE OCCURS • • EXISTING SPRINKLER IN D DEMO PROJECT NUMBER: 222008 Healthy Living T.I. %"DIA x 1 %4"SIMPSON Zfl TITENHDATCLTRACK anno reek ace • Bldg. B JAMB COLUMN x1 N F N 16083 SW Upper Boones N Ferry Rd. Suite 310 & 330 6. JAMB DETAIL FOR BOX BEAM HEADER 1. REFLECTED CEILING PLAN Tigard, OR 97224 SCALE. 3"= 1'-0" SCALE. 1/8"= 1'-0" 1/2"DIA. BOLT AT ANGLE CL EXISTING _ _ (2)362T150-33 STRUCTURE 4 A401 20 GA x 2"DEEP EXISTING STRUCTURE #8 TED SCREW SLOTTED TRACK L4 x 3 x 3/16(LLV) AT 8"O.C.TYP W/(2)#10 SCREWS AT 18" L1 1/2"x 1-1/2"x U-3-1/4" Lt Y x 1 Y x 16ga x 0'-3%"TOP 3 O.C.TO LOW (DIETRICH LS542 OR AND BOT(DIETRICH LS543 OR A401 BOX HEADER (2) 120OS162-68 DECK FLUTE EQUIVALENT)w/(3)#10 EQUIVALENT)W/(3)#10 SCREWS PER 5/A401 SCREWS EA. LEG EACH LEG SHEET TITLE: 362S1 62 33 AT THIRD POINTS OFH-1REFLECTED � AT 362S162-33 AT 24" � TYPICAL JAMB: O.C. . � (2)362S162-33 BOXED „ L1;/2 x 1 Y2 x 16GA x 0'-3 Yn" b 0 0 0 FULL HEIGHT EA SIDE CEILING PLAN & (DIETRICH LSR46 0R EQ.) . . . . . -- HEADER DETAILS W/(2)#10 SCREWS EA LEG —– -- LNNL-j 6.0 BOX HEADER PER 5/A401 (3)#10 SCREW 6 5/8"GYP BOARD ALL SIDES A401 S' DIETRICH H546 W/(20) TMP DRAWN BY: GV F3 #10 SCREWS ` DATE ISSUED: JAMB BEYOND VIF LL RELITE AS SPECIFIED PERMIT SET 02.07.22 8 I, N h I N O 0 5. BOX BEAM HEADER 4. BOX BEAM HEADER 3. JAMB TO BOX BEAM HEADER CONNECTION 2. BOX BEAM HEADER ELEVATION a SCALE: 3"= V-0" SCALE.' 1-1/2"= V-0" SCALE.' I"= 1'-0" SCALE: 1/4"= V-0" A 2 SHEET: 401 E LRS Architects,Inc 02022 N N N P Lf POWER / DATA LEGEND A R C H I T E C T S 720 NW Davis 503.221.1121 — WALL FIXTURES Suite 300 503 221.2077 PHASE OF SF FIXTURE Portland OR 97209 www.lrsarchitects.com OF NOT NEFI TUR HEIGHT ` H STANDARD) II E=EXISTING _ R=RELOCATED FIXTURE OPTIONS II j N I D1 5i � DUPLEX RECEPTACLE D,2 (EE OUTLET OPTIONS: !�a� STORAG 240V N 334 D=DEDICATED GFI=GROUND FAULT INTERRUPTION (E� N OFFA O DATA/TELEPHONE OUTLET N 333 - 1!� V CE Ej -4 SINGLE POLE SWITCH N OFFI �, 2-2-SWITCH OPTIONS: N 332 2=2-WAV POLE a(• '� 3=3-WAY POLE (E� CF �/ D=FANMER P 3 N OFFS OS=OCCUPANCY SENSOR o ?+63N 331 N O N " N FLOOR FIXTURES CONSULTANT: C� 6 CPT O FLOOR OUTLET DNF. Of ROOM �) 2 N (E)BREAK 31 ROOM (E)cbPr (N�ENTRY 335 , FINISH MATERIAL SCHEDULE 330_ i / I ___... ____ I (EE N OFFIC N 4 Z L O318 rn PT-1 CARPET D4 `r A801 CPT-1 MFR: TBD P-1 PAINT 2 PRODUCT: MFR: TBD COLOR: COLOR: CE) TYPE: TBD LOCATION: WALLS, LINO OFFI ■ __- O ■ - INSTALLATION:TBD 317 SUITEENTREY LOCATION: THROUGHOUT U.N.O. o FE 310 N PL-1 PLASTIC LAMINATE-VERTICAL I I VT-1 LUXURY VINYL TILE MFR: TBD STAR#1 MFR: TBD COLOR: I I (E) 3 I PRODUCT: FINISH: N OFFICE ti -----------"------------ 318 COLOR: LOCATION: COFFEE AREA L____________ Tn N O O SIZE/THICKNESS: ■ . N ■ ■ SEAMS: LOCATION: COFFEE AREA PL-2 PLASTIC LAMINATE-HORIZONTAL ry (E Imo-I= Imo-L� MFR: TBD OFFICE O COLOR: 315 RB-1 RUBBER BASE n I n I n I FINISH: IF RUBBER II h n MFR: TBD OFFICE COLOR: LOCATION: COFFEE AREA 311 °i ` -- III . -- . -- SIZE: VIII " LOCATION: THROUGHOUT n u u OFFICE 314 II PAINT FINISH NOTES - IIIA ISI "N A. PAINT BOTTOM AND SIDES OF SOFFITS TO MATCH ADJACENT CEILING PROJECT NUMBER: 222008 COLOR UNO. B. PAINT ALL NON-NOTED MISCELLANEOUS ITEMS TO MATCH ADJACENT FINISH COLOR UNO. Healthy Living T.I. y i i�lpl� E C. INTERIOR PAINTS ARE TO HAVE THE FOLLOWING SHEENS UNO: OFFICE A801 FII • WALLS- EGGSHELL I i(f} 313 _T= =T ! ( C PEF I • CEILINGS &SOFFITS- FLAT Fanno Creek Place " AVA2 DOORS, DOOR FRAMES, CASINGS AND MILLWORK- SEMI-GLOSS Bldg B LEGEND: F FLAT FEF r-,11 V VELVET ■ ii If (tiIC)i E EGGSHELL 16083 SW Upper Boones - N ------ _ N S SATIN Ferry Rd. Suite 310 & 330 G SEMI-GLOSS 1. DEMOLITION PLAN 2, FLOOR PLAN Tigard, OR 97224 SCALE: 1/8"= 1'-0" SCALE: 1/8"= V-0" (I GENERAL NOTES DEMO PLAN LEGEND GENERAL NOTES FLOOR PLAN LEGEND KEYNOTES A. THIS DRAWING DEPICTS EXISTING CONDITIONS FOR REFERENCE EXISTING TO REMAIN A. THIS DRAWING DEPICTS EXISTING CONDITIONS FOR REFERENCE EXISTING PARTITION O PATCH AND PAINT WHERE NEEDED. ONLY.VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF ONLY. VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK AND REPORT ALL DISCREPANCIES TO ARCHITECT. DEMOLISH EXISTING ELEMENT WORK AND REPORT ALL DISCREPANCIES TO ARCHITECT. ® NEW FULL HEIGHT DEMISING WALL TO STRUCTURE O NEW CONFERENCE ROOM GLASS PARTITION. SEE 8/A801 FOR SIZE AND B. DIMENSIONS ARE TO FACE OF FINISH, UNO. DIMENSIONS NOTED TAKE B. DIMENSIONS ARE TO FACE OF FINISH, UNO. DIMENSIONS NOTED TAKE (SEE DETAIL 5/A801) CONFIGURATION. PRECEDENCE OVER SCALE. PRECEDENCE OVER SCALE. O RECITE PARTITION EXISTING WALL TO BE BUILT FULL HEIGHT TO UNDERSIDE OF C. PROTECT ALL ADJACENT AREAS DURING DEMOLITION AND FROM DUST C. REPAIR AREAS ADJOINING DEMOLITION WORK TO MATCH EXISTING �� 3 STRUCTURE. (SEE DETAIL 5/A801) AND TRASH INTRUSION. AND/OR NEW CONSTRUCTION. D. ALL DEMOLITION WORK TO CONFORM TO CURRENT OSHA STANDARDS. D. PROVIDE BREAK METAL AND SOUND CAULK AT ALL WALLIMULLIONDOOR& RECITE TYPE. (SEE DETAIL 8/A801 Oq RECONFIGURE DEDICATED LIGHTING FOR SWITCH. PROVIDE ADEQUATE BRACING ON EXISTING CEILING FRAMING SYSTEM JOINTS. ) PRIOR TO DEMOLITION. E. ALL DOOR OPENINGS TO BE 5" FROM PERPENDICULAR WALL, LINO. O PROVIDE WATER LINE AND PLUMBING FOR SINK. PROVIDE GARBAGE E. REPAIR ANY DAMAGED WINDOW MULLIONS, SILLS OR TRIM AT F. ALL NEW& EXISTING OUTLETS, SWITCHES AND COVER PLATES TO BE DISPOSAL FOR SINK. PERIMETER OF BUILDING WHERE WALL(S)WERE REMOVED. BUILDING STANDARD. PROVIDE AS NEEDED. SEMI-RECESSED FIRE PROVIDE FLUSH MOUNTED FLOOR BOX WITH POWER/DATA/HDIM/ IN F. REMOVE EXISTING FLOORING AND BASE UNO. REFER TO FINISH PLANS G. WHEN NEW LIGHT SWITCHES ARE ADDED TO ANY PORTION OF THE FEE C EXTINGUISHER CABINET O (1) FOR MORE INFORMATION. SUITE, REPLACE ALL EXISTING LIGHT SWITCHES WITH NEW BUILDING CONDUIT TO TENANT PROVIDED WALL MOUNTED TV. CONFIRM FINAL g G. REMOVE ALL UNUSED BLANK JUNCTION BOXES. PATCH AND PAINT. STANDARD OCCUPANCY SENSOR SWITCHES. INDICATES FINISH DIRECTION -TBD PLACEMENT /FURNITURE VENDOR. CONFIRM POWER/DATA SHEET TITLE: H. FURNITURE INDICATED ON PLANS IS FOR REFERENCE ONLY. REQUIREMENTTWITH ITH TENANT. 1. ALL FIXTURES SHOWN ARE ASSUMED NEW UNO. CPT' FLOOR FINISH CONSTRUCTION J. ALL LOW VOLTAGE CABLING TO BE PROVIDED BY TENANT. GC TO /� �Na7+ D Ot PROVIDE J-BOX WITH RING AND STRING AT LOCATIONS SHOWN. PLMFINISH K. EXISTING POWER AND DATA SHOWN FOR REFERENCE ONLY. CONFIRM LOCATIONS ONSITE. INFO s KEYNOTES $ D1 REMOVE WALL MOUNTED WOOD PANEL. PATCH AND PAINT WALL TO r MATCH SUITE STANDARD. R D2 EXISTING FLOORING TO STAY. REPLACE RUBBER BASE TO MATCH DRAWN BY: GV m SUITE STANDARD. DATE ISSUED: D3 CONTRACTOR TO PROTECT LOWER &UPPER CASEWORK WHILE REMOVING EXISTING WALL AND CONSTRUCTING NEW DEMISING WALL. 0 OREMOVE PORTION OF EXISTING HALLWAY WALL FOR NEW BUILDING PERMIT SET 02.07.22 STANDARD SUITE ENTRY DOOR. N N DS RETURN REMOVED DOOR AND RELITE TO OWNER'S STOCK PILE. S e a 3 SHEET: A201 a E LRS Arohitecf5.Inc.m 2022 m LA Lf 2'-1"U .O.N. GENERAL NOTES A R C H I T E C T S 720 NW Davis 503.221.11211@ CLEAR SILICONE CAULK AT SEAM(TYP) A. THIS DRAWING DEPICTS EXISTING CONDITIONS FOR REFERENCE Suite 300 503 221.2077 D PLASTIC LAMINATE COUNTERTOP&SPLASH ONLY. VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF AT ALL EXPOSED SURFACES&EDGES(SEE 3 VERTICAL WORK AND REPORT ALL DISCREPANCIES TO ARCHITECT. Portland OR 97209 www.Irsarchitects.com ELEVATION)OVER 3/4"SUBSTRATE A801 SURFACES, PLA B. DIMENSIONS ARE TO FACE OF FINISH, UNO. DIMENSIONS NOTED TAKE 31-11. PRECEDENCE OVER SCALE. RESILIENT FLOORING AS �_ EQ.CABINET DOORS C. SEE FINISH SCHEDULE FOR MORE INFORMATION. SPECIFIED 'v CARPET AS SPECIFIED 6"DRAWER 00 4"WIRE PULLS, BRUSHED �� (� ALUMINUM(TYP) --- PLASTIC LAMINATE AT ALL - SEMI-EXPOSED SURFACES OVER I L T F CASEWORK NOTESR . ► / n / • V ` ' 0 3/4"SUBSTRATE;SELF EDGE 4 'ii WHITE INTERIOR w/ADJUSTABLE REF �. A. EURO STYLE BOXES WITH FULL OVERLAY DOORS AND DRAWERS. OF . SHELVES(TYP) (NIC) B. CONSTRUCTED IN ACCORDANCE WITH NAAWS 4.0 2021 CUSTOM • - m e i BASE AS SPECIFIED; REFER TO o I I GRADE ELEVATION N DW C. PLASTIC LAMINATE CABINETS WITH MATCHING PVC EDGE BANDING. D. WHITE MELAMINE INTERIORS UNO (GRAY AT PULL OUT TRASH BINS X � AND BLACK WHERE PLAM IS DARK. ALUMINUM TRIM E. PROVIDE COMMERCIAL GRADE EURO HINGES, FULL EXTENSION REDUCER _ RUBBER BASE, HORIZONTAL CONSULTANT: MATCH BUILDING STANDARDRB-1 4 2 SURFACES, SLIDES AND QUIET SELF-CLOSING HARDWARE. T.O. FIN. FUR A801 A801 PL-2 F. SCRIBE FIT FILLER STRIPS TO FINISH ALL CASEWORK AT ALLS AND CEILINGS, FILLER STRIP TO MATCH CASEWORK. 3'-9" 3'-0" 2' 0" G. PROVIDE FINISHED PANEL(S)ON ALL EXPOSED EQUAL CABINE S R VIF R. SIDES/BACKS/ENDS/UNDERSIDES. 7. CARPET TO RESILIENT FLOORING TRANSITION 4. LOWER CABINET W1 DRAWER & DOOR 1. COFFEE AREA SCALE: FULL SCALE: 1"= 1'-0" SCALE: 1/4"= V-0" DOOR GENERAL NOTES A. ALL DOORS SHALL MEET ALL APPLICABLE FEDERAL AND STATE ACCESSIBILITY REQUIREMENTS 18 GA.DEFLECTION CHANNEL CLEAR SILICONE CAULK AT SEAM • MINIMUM 32"CLEAR OPENING WIDTH SECURE TO METAL DECK W/ (TYP) . MAXIMUM 1/2"THRESHOLD HEIGHT UNLESS SHOWN WITH COMPLIANT 1/4"DIA.X 1-1/2"POWER 2'-1"U.O.N. ACTUATED FILLED FLUTES @ 18" CHROME ACCESSIBLE FAUCET RAMPTHRESHOLDS CONCETE FILLED FLUINTO . ADJUST THE RESISTIVE FORCE OF ALL NEW AND EXISTING INTERIOR O.C. OR#8 S.M.S INTO METAL 6.5"DEEP ADA COMPLIANT DOOR CLOSERS IN THE PROJECT AREA TO A MAXIMUM PRESSURE OF 5 DECKLBS CONTINUE 3/4"DEFLECTION.18"O.C. PROVIDE FOR 1„ STAINLESS STEEL KITCHEN SINK B. PROVIDE DOOR OPENINGS IN RATED WALLS COMPLYING WITH REQUIRED GYP.BD.TO PLASTIC LAMINATE COUNTERTOP SMOKE CONTROL ASSEMBLY AND INDICATED FIRE PROTECTION RATING OF CEILING &SPLASH AT ALL EXPOSED NO LESS THAN 20 MINUTES.WHERE EXISTING DOOR OPENINGS DO NOT --- SEE RCP _ SURFACES&EDGES(SEE COMPLY WITH PRESENT BUILDING CODE REQUIREMENTS, PROVIDE NEW ELEVATION)OVER 3/4" DOORS, FRAMES AND HARDWARE THAT COMPLY CEILING SYSTEM AS SPECIFIED MEDIUM-DENSITY FIBERBOARD C. SAFETY GLAZING MUST BE PROVIDED FOR INDIVIDUAL GLAZED AREAS IN WHERE OCCURS(REFER TO MADE W/EXTERIOR GLUE. HAZARDOUS LOCATIONS AS DEFINED IN IBC SECTION 2406 RCP) D. ALL DOORS SHALL OPEN FROM THE INSIDE WITHOUT THE USE OF A KEY OR % \ 4"WIRE PULLS, BRUSHED ANY SPECIAL KNOWLEDGE OR EFFORT ALUMINUM E. CONTRACTOR SHALL VERIFY COMPATIBILITY OF HARDWARE SPECIFIED WITH / 3-5/8"25 GA(362S125-18)MTL BUILDING KEYING SYSTEM // // STUDS 24"O.C.WITH 5/8" GYP. _ PLASTIC LAMINATE OVER 3/4" m �� �� @ o F. SALVAGE REUSE EXISTING DOORS, FRAMES&HARDWARE WHERE BD.EACH SIDE. EXTEND MTL SUBSTRATE REMOVABLE BASE POSSIBLE.. ALL NEW WOOD DOORS TO MATCH EXISTING SIZE,WOOD GRAIN, PROJECT NUMBER: 222008 zz STUDS AND GYP.BD. FULL HEIGHT v CABINET DOORS W/ FULLY BLACK HEAT Z FINISH&COLOR.TOUCH UP EXISTING FRAMES&DOORS WHERE NEEDED TO TO UNDERSIDE OF STRUCTURE CONCEALED EUROPEAN HINGE & \ PROOF WRAP � APPEAR AS NEW Healthy Living T.I. ABOVE. PROVIDE 3"SOUND QUICK SNAP OFF CAPABILITY � ATTENUATION BATT INSULATION @EXPOSED ih FRICTION FIT IN STUD(SEE NOTE PIPING WHITE INTERIOR(TYP) 18'-10" �, POWDER DRIVEN BELOW FOR MORE INFORMATION). FannO Creek Place 7 4 EQUAL ANCHOR AT 2'-0"O.C. RUBBER BASE THRU MTL.STUD BASE ON BOTH SIDES AS A801 TRACK,UON SPECIFIED TO. FIN. FUR _ DOOR STANDARDS Bldg. B �T UNDERCUT BY 1/4"FOR FLOOR EXISTING SLAB CLEARANCE,ATTACHED TOE KICK WOOD DOORS: 16083 SW Upper Boones CONTINUE FLOOR FINISH UNDER SC-WD: SOLID CORE HARDWOOD PLAIN SLICED MAPLE WITH TRANSPARENT CABINET AT SINK, SEE FLOOR PLAN BUILDING STANDARD FINISH Ferry Rd. Suite 310 & 330 8. CONFERENCE ROOM GLAZING ELEVATION 5. DEMISING WALL (METAL/CONCRETE STRUCTURE) 2. TYPICAL LOWER CABINET w/ SINK MATCH BUILDING STANDARD Tigard, OR 97224 SCALE. 1/4"= 1'-0" SCALE. 1/2"= 1'-0" SCALE: I"= 1'-0" DOOR SCHEDULE KEYNOTES 1. PASSAGE LATCHSET CONTINUOUS FRENCH CLEAT 1'-0"U.O.NJ. . a S o R PLASTIC LAMINATE AT ALL EXPOSED& 4 SEMI-EXPOSED SURFACES OVER 3/4" SHEET TITLE: Q� 4� 9 SUBSTRATE; SELF EDGE ELEVATIONS & DETAILS o q WHITE INTERIOR w/ ADJUSTABLE SHELVES(TYP) 4"WIRE PULLS, BRUSHED F 1 ALUMINUM(TYP) FLUSH SINGLE OPENING DOOR m S DRAWN BY: GV m DATE ISSUED: a Y U 0 PERMIT SET 02.07.22 LLmp O N N N N O 6. DOOR & FRAME TYPE 3. TYPICAL UPPER CABINET a SCALE: 1/4"= 1'-0" SCALE: 1"= 1'-0" A801 SHEET: LL a E LRS A¢hikcts,Inc®2022 m m El