Loading...
Plans (27) BUP2021 -00224 OFFICE COPY 01 00 00 GENERAL DATA 6. FINISH: <CLASS I DARK BRONZE ANODIZED FINISH(OR BLACK-MATCH EXISTING),0.7 MILS THICK><CLASS I d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING C. CONDENSATE MUST BE TRAPPED AT UNIT. TENANT I M ROV E M E N T CLEAR ANODIZED FINISH,0.7 MILS THICK> AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. �� K, GENERAL REQUIREMENTS 10.SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED METHOD. 09 00 00 FINISHES e. PROTECT WORK OF OTHER TRADES. 1. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND 11.ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PIPING SHALL BE RUN NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. GENERAL f. PROVIDE"WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. INSIDE OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND �. fa 10 00 00 SPECIALTIES CLAMPED(STAINLESS STEEL WORM GEAR). f 2. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING 1. REMOVE ALL EXISTING VCT,SHEET VINYL, ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR for MARTIN W.HANSON C� CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED TO INSTALLATION OF NEW FLOORING. 12.ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND RECEIVED �' 10 28 13 REST ROOM ACCESSORIES(SINGLE OCCUPANCY) CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE CORROSION WITH OIL BASED PAINT(COLOR GREY). THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 2. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS.EXCLUDES LVT AND 1. REUSE EXISTING ACCESSORIES WHERE POSSIBLE. 13.LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND SOME VCT APPLICATIONS.VERIFY WITH ARCHITECT PRIOR TO APPLYING WAX COATINGS. PACTRUST CLACKAMAS,OREGON 3. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE 2. PAPER TOWEL DISPENSER,SURFACE MOUNTED(ONE PER RESTROOM)BOBRICK B-262. RADIUS OF MANUFACTURER'S GUIDELINE. SEPL 2 2021 cf� EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK 3. EXISTING VCT TO REMAIN TO BE STRIPPED AND APPLY NEW WAX COATING. 3. LAVATORY MOUNTED SOAP DISPENSER 34 FL OZ.,4"SPOUT LENGTH BOBRICK B-822. 14.ECONOMIZER TO MEET CODE AND AS FOLLOWS: � O DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO 4. SUBMIT ONE SAMPLE OR DRAW DOWN NO LARGER THEN 11 X 17 FOR THE FOLLOWING: CITY OF TIGARD �� �� ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE 4. SURFACE MOUNTED MULTI-ROLL TOILET TISSUE DISPENSER BOBRICK B-2888. a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. BUILDING DIVISION .� OP Og, LEFT IN THE TENANT SPACE AS NOTED ON PLANS),CLEANING AND ALL PREPARATION OF SUBSTRATE a. FLOOR COVERINGS,BASE AND TRANSITION STRIPS 1' 5. SURFACE MOUNTED TOILET SEAT COVER DISPENSER BOBRICK B-0221. b. BAROMETRIC RELIEF ON 5.7 1/2 TON UNITS. �/�� ^��• SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. b. PLASTIC LAMINATES 6. MIRROR:BOBRICK B-126-2436 MIRROR WITH STAINLESS STEEL CHANNEL FRAME.24"X 36'. c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. Tenant: 4. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) .µ G,,11 STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS 7. GRAB BAR SATIN FINISH BOBRICK 8-6806 SERIES. d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. PROJECT #215'+0 INTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. d. PAINT 10 28 13 BREAK COUNTER 15.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. lob p 173 15822 Spec Space 5. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. e. TILE,MARBLE,GRANITE,STONE,GROUT AND SCHLUTER TRIMS 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHEN/BREAK ROOM)BOBRICK B-262 16.DROP CANS TO BE SAME SIZE AS CURB OPENING AND TO EXTENDED TO WITHIN 2'OF SUSPENDED CEIILING. 6. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING f. TOILET PARTITIONS MINIMUM 26 GAUGE FOR SUPPLY AIR. SEAL EDGES OF SUPPLY AIR. 1. FIRE44 16 FIRE EXTINGUISHERS PROJECT NARRATIVE CARPETS. 5. FINISH FLOORING TO EXTEND UNDER ALL NEW CASEWORK. 17.DISTRIBUTION DUCTWORK: 1. FIRE EXTINGUISHER 2-010 BC (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) 7. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF AND 6. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET PER TRANSITION a. SPIRAL DUCT PERMITTED ONLY IF EXPOSED. �i ROOF MEMBRANE TO MATCH THE EXISTING ROOF. STRIP DETAILS. 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. b. 26 GAUGE OR TO SMACNA STANDARDS WHERE DUCT IS CONCEALED ABOVE A CEILING. PROJECT CONSISTS OF REMODEL WORK TO 2,600 SF OF EXISTING OFFICE AND 0 8. ALL ROOF WORK TO BE COORDINATED WITH PACTRUST PROPERTY MANAGEMENT AND BE PERFORMED BY 7. PROVIDE SCHLUTER METAL TRIM AT ALL EXPOSED EDGES OF TILE(EXCEPT AT BULLNOSED EDGE) 12 00 00 FURNISHINGS c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH WAREHOUSE SPACE, SHELL MODIFICATIONS, AND MINOR SITE ALTERATIONS. ^^,, PACTRUST APPROVED ROOFING COMPANIES. APPROVED COMPANIES INCLUDE: 8. CONTRACTOR TO PROVIDE 10%ATTIC STOCK FOR ALL FLOOR TILE PRODUCTS UNLESS DIRECTED 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT PLL EXTERIOR GLASS. MINIMUM R4.2 INSULATION WITH FSK BARRIER. � a. ARROW ROOFING, 503460-2767 OTHERWISE. 2. PROVIDE VERTICAL BLINDS AT ALL EXTERIOR WINDOWS. d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD WORK SHALL INCLUDE BUT NOT BE LIMITED TO b. ROOF TOPPERS,360-574-7248 09 21 00 GYPSUM BOARD a. MARIAK CONTRACT CHAIN/CORD OPERATED VERTICAL BLINDS HANGERS AND FULL DIAMETER STRAP UP TO 18"O. LARGER THAN 18"MUST HAVE SADDLE TYPE CLAMP. • SELECTED DEMO OF EXISTING NON STRUCTURAL WALLS c. GOT YOU COVERED ROOFING,503-975-9136 GENERAL b. NO VALANCE e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 • NON STRUCTURAL DRYWALL/METAL STUDS WALLS U 1O.CONTRACTOR MAY SUBMIT ALTERNATE ROOFING CONTRACTOR TO BE REVIEWED AND APPROVED BY 1. ALL GYPSUM BOARD WALLS: ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHT ANGLES OR c. FABRIC-MARIAK 3.5'SOLID PVC VANES-OFF-WHITE DEGREES. • DOORS/FRAMES AND PAINTING PACTRUST PRIOR TO BID. PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN WITH 1"TYPES I. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12" 12 23 16 CABINET SPECIFICATIONS • ELECTRICAL DISTRIBUTION O.C.TO TOP AND BOTTOM RUNNERS AND 11.VERIFY WITH BUILDING OWNER ANY ROOF WARRANTY REQUIREMENTS. g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. 12.KEEP THE ROOF FREE OF DEBRIS I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING), 1. ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR AT ALL RESILIENT FLOORING LOCATIONS. • LIGHTING ( EACH SIDE AND OPPOSITE SIDES. 18.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. 13.ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH 2. AWI CUSTOM GRADE STANDARDS FOR CASEWORK AND COUNTER TOPS U.N.O • EXTERIOR CONCRETE FLAT WORK AND ASPHALT WORK � O 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN 19.DIFFUSERS: A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 FINISH COATS(LEVEL 4 FINISH). PAINT AS INDICATED. 3. HIGH PRESSURE LAMINATE(P-LAM HPL)ALL EXTERIOR SURFACES, INCLUDING 4"TOE KICK. EDGE BANDING O O POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. (MATCHING PVC ACCEPTABLE),FIN ENDS,DOORS,AND LIGHT VALENCE ETC. UPPER CABINET BOTTOMS a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN ALL WORK TO MEET ADA REQUIREMENTS. m 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH OPTIONAL HPL FINISH,STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH,STANDARD TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. U) 14.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS U A DAILY BASIS INCLUDING DOCK ACCESS COAT(LEVEL 3 FINISH). PAINT AS INDICATED. MELAMINE FINISH. b. GYPSUM BOARD CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE- C AREAS AND COMMON AREA. FLOORS AL BE SWEPT IM VACUUMED DAILY. 4. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER DESIGN TITUS 350;EXHAUST-METAL OR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN TITUS 50F. WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT 15.PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO 4. TOE KICK PLYWOOD 4"H WITH P-LAM COVER METAL STUDS. Y c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN D COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL 5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11116"PARTICLE BOARD WITH MATCHING P-LAM OR DUCT AT OR NEAR CLOSEST T a 'Cr BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION 5. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT.QUIETJOINT SHH WHERE WALL PVC EDGES. WYE BRANCH. .J.. C-4 ACTIVITIES. MEETS MULLION AND EMSEAL WHERE WALL MEETS GLAZING.COLOR SELECTED BY ARCHITECT. PLUMBING WORK Q fV 6. MELAMINE(LOW PRESSURE LAMINATE/LPL)ALL INTERIOR AREAS,DRAWER PARTS,SHELVING ETC. d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT HEATING VENTILATION &AIR CONDITIONING WORK O I,- 16.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING 6. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND COMPLETION. , RESTROOM FACILITIES. PATCH HOLES READY FOR PAINT. 7. FLUSH OVERLAY/FRAMELESS STYLE CONSTRUCTION. ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE Z) 0_ 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE 17.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT 7. REPAIR GYPSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR 8. THERE SHOULD BE 1/8"OR LESS GAP TOLERANCE BETWEEN DOORS AND DRAWERS. HONEYWELL COMMERCIAL GRADE WSIONPRO 8000 TOUCH SCREEN MODEL TB822OU1003 WHERE POSSIBLE, W O 00 � PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER PAINT. 9. HINGES-BLUM#75M3580, 110 DEG.SELF CLOSING CLIP ON(OR EQUAL). PROGRAMMABAPPROVED BE WITH LOCKOUT FUNCTION AUTO CHANGEOVER ONLSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL Y. MOUNTASTAT �ADA EIGHT(MAY EL NO.P374-2800 7 DAY Q Cl) � COMMON BUILDING AREA BE USED FOR STORAGE. 8. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. tO.DRAWER SLIDES-BLUM #230M SERIES EXTENSION(OR EQUAL)75 LBS.MIN.FOR STANDARD DRAWERS. REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM BUILDING INFORMATION TENANT INFORMATION •- Z ' 18.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. WALL CONSTRUCTION MATERIALS ACCURIDE#4032(OR EQUAL)HD/FULL EXT 150 LBS.MIN. FOR HD AND FILE DRAWERS. THERMOSTATS AND BALANCE SYSTEM. OWNER: PACIFIC REALTY ASSOCIATES, L.P. TENANT: (N CN 19.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, 1. PROVIDE STUDS,TRACKS,BRACING, FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE 11.PULLS-96 MM C-TO-C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. 21.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. 15350 SW SEQUOIA PKWY#300 20b 173-15822 Spec O F- CC) CID ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. INSTALLATION. p p Cu Lo w M M 12.GENERAL CONTRACTOR TO PROVIDE CABINETMAKER WITH SINK TEMPLATE(SPEC SHEETS)FOR EACH SINK. 22.WAREHOUSE HEAT: PORTLAND, OR 97224 Co 20.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED ON PLANS WHERE PHYSICAL SINK CUTOUT SHALL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACK SPLASH IS INSTALLED IN ALL C L0 a O O a. GAS FIRED UNIT HEATERS USED IN NON-CONDITIONED AREAS SHALL COMPLY WITH CURRENT STATE OCCUPANCY AREAS&LOADS: G Lo LO STRUCTURAL PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED CASES TO ALLOW CUT OUT TO BE POSITIONED PROPERLY. ALL RAW EDGES OF CUT OUT AND BACK SPLASH D_ � 21.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. ENERGY CODE REQUIREMENTS. PROVIDE ADJUSTABLE TSTAT FOR EACH UNIT. LIVE LOADS. DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. TO BE SEALED. MINIMIZE COUNTERTOP BUILD UPS AT FRONT AND BACK OF SINK CUT OUT TO (503)624-6300 (PHONE) B 1,514 SF 11 OCC 22.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 ACCOMMODATE PLUMBERS SINK CLAMPS CLEARANCE. 25.EXHAUST FANS: (503)624-7755(FAX) S-2 1,086 SF 3 OCC 23.CLEAN ALL SUPPLY AND RETURN DIFFUSERS AT PROJECT COMPLETION. PSI)G60. 13.KITCHEN/BREAK ROOM CABINETS-BASE CABINET WITH P-LAM TOP ON PLYWOOD DECKING AND 4"BACK a. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT TOTAL 2,600 SF 14 OCC 1 EXIT REQ U 24.UPON COMPLETION OF THE PROJECT,THE CONTRACTOR MUST PROVIDE A DETAILED CLOSEOUT PACKAGESPLASH. ALL CABINETS TO HAVE DOORS AND DRAWERS,U.N.O. UPPERS 12"D X 36"H-ATTACH TO WALL CODE REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR. PER INSTRUCTIONS INCLUDED IN THE CONSTRUCTION CONTRACT.RETENTION WILL BE HELP PER CONTRACT 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR WITH FRENCH CLEAT,COUNTER AND COUNTERTOPS 24"DEEP. MICROWAVE SHELF 18"D WITH 3"RADIUS COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS, 100 CFM WITH A BLDG.#: OBP II BLDG. C (2obp173) O1 UNTIL THE COMPLETED CLOSEOUT PACKAGE IS RECEIVED AND HAS BEEN APPROVE BY THE CONSTRUCTION AN APPROVED EQUAL. OUTSIDE CORNERS. P-LAM AT TOE/BASE. ALL SHELVES ADJUSTABLE.PROVIDE HOLES AND POSTS 1 AT SONE RATING OF.9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. MANAGER,ARCHITECT,AND PROPERTY MANAGER. 5. STANDARD GYPSUM BOARD SHALL BE TYPE W,5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM BASE,2 AT UPPERS). CONST.TYPE.: III-B NOT SPRINKLERED Co C-36. b. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING .".� 25.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, 22 00 00 PLUMBING : DESIGN/BUILD MOUNTED EXHAUST FANS,WIRED PER DIVISION 16 AND SWITCHED WITH THE LIGHTS. M FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM GENERAL REQUIREMENTS 26.HVAC TESTING. BUILDING AREA: 29,138 TOTAL n TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF C-630. WHETHER OR NOT SHOWN ON THE DRAWINGS. 7. AT TOILET ROOMS USE 5/8"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR 1. CONTRACTOR TO SUBMIT LAYOUT ON ELEVATIONS AND PLANS PROVIDED FOR ALL SHUT OFF VALVES,CLEAN a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, JCL 26.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". OUTS,ACCESS DOORS,AND FLOOR DRAINS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH ALLOWABLE AREA PER 2014 OSSC. O TO 48"A.F.F.ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES. (EXCEPTION:EXCEPTION AT LOCATIONS TO RECEIVE PLASTIC LAMINAE C OR TILE WAINSCOT.) 2. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUT OFF VALVE FOR EACH SET OF APPROVED PLANS AND SPECIFICATIONS. 27."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD%:"THICK WITH SQUARE,REINFORCED, RESTROOMS. LOCATE VALVE BEHIND HANDICAP WATER CLOSET IN MEN'S TOILET ROOM. b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN TYPE AREA FRONT. INC. TOTAL ALLOWED PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL. 3. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS. ALL EXPOSED PIPING TO BE B= 19,000 + 14,250 = 33,250 SF 28.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. g. INSTALL WATER-RESISTANT GYPSUM BOARD BEHIND WAINSCOT OF FRP,PLASTIC LAMINATE,ETC. INSULATED. c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND 21.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN FILED WITH PACTRUST. S-2 = 26,000 + 19,500 45,500 SF TWO WEEKS OF PROJECT AWARD.SAMPLES SHOULD BE NO LARGER THEN 11 X 17 AND TAGED WITH 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. 4. WATER HEATER(ELECTRIC)30 GAL AND LARGER 277V LESS THAN 30 GAL 120V. PROVIDE HUB DRAIN AT = MANUFACTURES LABEL.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO LOCATION FOR BLOW OFF. 27.PROJECT CLOSE OUT DOCUMENTS REQUIRED: REPLACEMENT AT CONTRACTOR COST.AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL 11 SYSTEM. PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH 5. POINT OF DEMAND WATER HEATER-BOSCH POWER STREAM PRO-MODEL RP2P 277V/30A ADJUST WATER a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. CODE SUM MARY REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE WALL CONSTRUCTION EXECUTION FLOW SETTING TO PROVIDE A HEATING RANGE OF 105 TO 120 DEGREES. b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH STATE CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS 6. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. NO ATMOSPHERIC c. HARD COPY OF AutoCAD FILE ABOVE. DIRECTED AT CONTRACTOR'S COST. 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING PRIMERS, DRAINS TO BE PRIMED FROM TOILET FIXTURES UNLESS OTHERWISE APPROVED BY AND LOCAL CODE REQUIREMENTS THAT APPLY, INCLUDING BUT NOT 22.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL, ELECTRICAL AND SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW PACTRUST. PROVIDE A MIN. 12"x 12"ACCESS DOOR. d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING T-STATS. LIMITED TO: PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD PLUMBING-REST ROOM FIXTURES(SINGLE OCCUPANCY) e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE MATERIALS LIGHTER THAN 18 GA. 2019 OREGON STRUCTURAL SPECIALTY CODE (OSSC) COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR.SUBMITTALS MAY BE DELIVERED IN PDF 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS 1. REUSE EXISTING FIXTURES WHERE POSSIBLE. 26 00 00 ELECTRICAL : DESIGN /BUILD • 2019 OREGON MECHANICAL SPECIALTY CODE (GMSC) FORMAT FOR REVIEW. INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. 2. WALL HUNG LAVATORY TOTO LT307A,OR AMERICAN STANDARD 0356.115. GENERAL 2017 OREGON PLUMBING SPECIALTY CODE 23.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE OPSC SLABS. 3. LAVATORY FAUCET-AMERICAN STANDARD,COLONY PRO 7075.104 SINGLE CONTROL,LESS POP-UP ROD& 1. ALL ELECTRICAL FEEDS TO OUTLETS,SWITCHES, ETC.MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR ( ) CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION HOLE. HORIZONTAL RUNS UNDER WINDOWS AND RECEPTACLES ON THE SAME STUD. I • 2017 OREGON ELECTRICAL SPECIALTY CODE (OESC) IIIIIIIIIIIII LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT, ALL SPRINKLER HEADS SHALL BE LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE 4• TOILET FLOOR MOUNT TANK TYPE TOTO CST744EL(SL AT ADA STALL)OR KOHLER CIMARRON K3496. 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING • 2019 OREGON FIRE CODE (OFC) CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE 5. TOILET SEAT: BEMIS 1955SSCT OR OLSONITE tOSSCT. SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. • ASCE-7-10 0) APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY STUDS AT CORNERS, POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP 3. ALL NEW ELECTRICAL DEVICES TO BE WHITE.NYLON COVER PLATES NOT ALLOWED. THE ARCHITECT PRIOR TO INSTALLATION.SUBMITTALS MAY BE DELIVERED IN PDF FORMAT FOR REVIEW. AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS.PROVIDE LONG LEG 6. AT BACK TO BACK TANK TYPE TOILET INSTALLATIONS US 3"VENT THROUGH ROOF. • ICC/ANSI A117.1-2017 24.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE. 7• PROVIDE FLOOR DRAIN AS INDICATED ON PLAN. 4. REPLACE ALL NON-WHITE EXISTING ELECTRICAL DEVICES TO WHITE.NYLON COVER PLATES NOT ALLOWED. • 2019 OREGON ENERGY EFFICIENCY SPECIALTY CODE 3 INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. 4. REMOVE EXISTING FLOORING AT NEW WALLS UNLESS SPECIFICALLY INDICATED BY ARCHITECT. 8. SEALANT OF PLUMBING FIXTURES: 5. WHERE INDICATED-POWDER COAT ELECTRICAL COVER-COLOR#HFWRO358"PURE WHITE" 01 73 29 CUTTING AND PATCHING AT CONCRETE SLABS AND SIDEWALKS 5. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR a. ALL SEALANT SHALL MATCH GROUT COLOR AT TILE SURFACES. 6. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. 11 THE PROJECT. 7. PROVIDE TYPEWRITTEN UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS, 1. PERFORM CUTTING AND PATCHING WITH SKILLED CRAFTSMEN EXPERIENCED WITH THE TYPE OF WORK b. SUBMIT SEALANT COLOR PRIOR TO INSTALLATION FOR ARCHITECT APPROVAL FOR ALL OTHER BEING UNDERTAKEN. 6. AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING,INSTALL THE GYPSUM BOARD(OR AUQATOUGH) APPLICATIONS. 8. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. METER FAsh PLUMBING-BREAK ROOM FIXTURES 2. PROTECT EXISTING CONSTRUCTION TO PREVENT DAMAGE. WITH 1/4"GAP BETWEEN THE BOARD AND THE FLOOR TO PREVENT WICKING. IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO TENANTS MOVE-IN. - - 7. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. 3. PERFORM CUTTING USING METHODS LEAST STING TO DAMAGE ELEMENTS TO BE RETAINED. 1. REUSE EXISTING FIXTURES WHERE POSSIBLE. 9. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN ON PLAN EQUAL TO , _ f't@CII+G /+Opv 4. PATCH,USING MATERIALS IDENTICAL TO EXISTING MATERIALS THAT VISUALLY MATCH EXISTING ADJACENT 8. FINISH QUALITY: 2. BREAK ROOM SINK ELKAY LRAD221955(TOP MOUNT). 1-FOOT CANDLE. OFFICE COPY i� SURFACES TO THE FULLEST EXTENT POSSIBLE. AREA PROCESS TRADE NOMENCLATURE 3. KITCHEN FAUCET-AMERICAN STANDARD COLONY SOFT SINGLE CONTROL FAUCET#4175.500. 10.EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH GREEN LETTERS,WHITE . .. 1 A OIj�G � 5. PATCH WITH DURABLE,INVISIBLE SEAMS THAT ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. WAREHOUSE TAPE/FINISH COAT' TIGHT DOUBLE(LEVEL 3) HOUSING,WITH BATTERY BACKUP. " 4. 1/4"COPPER WATER LINE W/SHUT OFF VALVE FOR COFFEE MAKER AND REFRIGERATOR,SEPARATE LINES IF FOR CUD&COPAPLiANC$ � 0 6. AT CONCRETE SLAB REPAIRS(POUR BACKS),PROVIDE#3 x 12"LONG REBAR DOWELS AT 24"O.C. MIN.WITH OFFICE/OTHER AREAS TAPE/2 FINISH COATS'/ SMOOTH FINISH TAPED(LEVEL 4) REQUIRED. 11.WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE - MIN.6"PENETRATION INTO EXISTING CONCRETE AND MIN.OF 6"EXPOSURE INTO POUR BACK.CENTER USG"FIRST COAT' •SAND AFTER TAPE/FINISH COAT(S) PROJECT CLOSE OUT DOCUMENTS REQUIRED: 208V/120V POWER FROM THE 48OV/277V SYSTEM. SIZE TO BE BIDDER DESIGN. •A7 U O DOWEL IN SLAB DEPTH. NOTE:AT EXTREMELY DARK ACCENT WALLS PROVIDE LEVEL 5 FINISH. a. TRANSFORMERS TO BE ENERGY STAR LABELED. ^` 7. REMOVE PATCHES THAT ARE VISUALLY UNSATISFACTORY IN THE ARCHITECTS OPINION AND REPLACE AT NO 1. PROVIDE AS-BUILT INFORMATION TO ARCHITECT AT PROJECT COMPLETION.INCLUDE THE FOLLOWING: �'(`� :;_ ' I i W �' ADDITIONAL COST. 9. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS a. DIMENSIONS (LOCATION AND DEPTH)OF BURIED PLUMBING LINES INSTALLED OR DISCOVERED BY THIS b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. / _ a- _ • 1 Q SHOWN ON PLANS. CONSTRUCTION. c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C #A•�!� - � (n w 03 00 00 CONCRETE 09 53 00 SUSPENDED ACOUSTICAL CEILING TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS v, b. LOCATION OF SHUT OFF VALVES. 1. EXTERIOR FLAT WORK: OPERATION. EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFC TAPS. MAXIMUM , 'a ;A .�tS W 1. PRODUCTS: ND - LL SOU LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN TH a. 4"THICK UN-REINFORCED CONCRETE SLAB WITH AIR-INTRAINMENT OVER 4"COMPACTED CRUSHED 23 00 00 HVAC : DESIGN /BUILD E CORE AND COIL N _ a. GRID-PRELUDE 24 XL 15/16"EXPOSED TEE(HEAVY DUTY) GAS METER ASSEMBLY AND CASE. INT `S ROCK(3/4 MINUS). ERSTATE 5, . ` V W co b. CONTROL JOINTS 5'O.C.MAX,EXPANSION JOINTS 20'O.C.OR AS SHOWN ON PLANS. b. TILES-ARMSTRONG FISSURED#705,24 x 24 x 5/8"W/ANGLED TEGULAR EDGE(FROM LANDLORD 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. 14.LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA)BY FUTURE TENANT. Srs i1 w /c'1_ I-s 1 CoQ Z MO STOCK) METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR 15.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. CARMAN RD. �if.�iJ� W c. BROOM FINISH,NO TOOLED EDGE.BROOM DIRECTION PERPENDICULAR TO SLOPE AT RAMPS. Exlr M291 - ' ^ a Q 0) 07 00 00 THERMAL& MOISTURE PROTECTION c. ACCESSORIES-MANUFACTURERS'STANDARD TO TENANTS MOVE-IN. 16.OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. - T J 2. ALL TILE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES. CUT/TRIM TILE EDGE TO CREATE TEGULAR EDGE HVAC-BID PROCEDURE 17.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT w ` U) m Ix 1. REPLACE ALL MISSING AND DAMAGED ROOF AND WALL INSULATION ABOVE THE CEILING GRID. CONDITION SO THAT CEILING TILES LAY FLAT. 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND I W D-' O 2. PROVIDE NEW ROOF INSULATION TO MATCH EXISTING AT ABANDONED MECHANICAL UNITS. 3. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. PROPER WORKING ORDER. SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE M Z W IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. ' C... _ - D- 0 3. AT ALL UN-USED EXISTING ROOF PENETRATIONS,REMOVE EQUIPMENT AND REPAIR ROOF SYSTEM. 4. TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL OVER THE ENTIRE SPACE. 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH G.o UNIT 18.UNUSED DATA AND POWER BOXES ABOVE STANDARD HEIGHT AND NOT ABOVE EXISTING CASEWORK TO BE qF Z) 08 10 00 DOORS AND WINDOWS 5. BENT OR DAMAGED T-BARS TO BE REPLACED. REMOVED AND INFILL WITH GYP BOARD. �� D �,. � B � m � j 3. LIST TONNAGE OF EACH UNIT. > > 1. RE-USE EXISTING DOORS,HARDWARE,AND FRAMES WHERE POSSIBLE. 6. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES4"EXPANSION SLEEVE. 19.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE dF A , BUILDING Q Z > (n HVAC-DESIGN PROCEDURE o s \��YYY"'��� DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION ° '0F O � 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: 09 65 19 RESILIENT FLOORING -SHEET VINYL FLOORING 0 0 U) O 1. USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS OF THE EXISTING LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING. REMOVE EXISTING LOW �P� T ii a. BAXTER AND FLAMING. (503)225-0486 1. SEAL THE EDGES OF THE SHEET VINYL FLOORING TO THE CONCRETE FLOOR WITH A CONTINUOUS BEAD OF LISTED BELOW. VOLTAGE FINISH PLUG AND INSTALL BLANK COVER PLATE,FINISH TO MATCH SPECIFICATIONS. No VALWW OF PERMIT W 00 W APPROVED SEALANT. SET THE 4"VINYL COVE BASE INTO AFRESH BED OF SEALANT TO SEAL THE BASE TO Q. LO Y b. D&D DOOR (503)205-5533 THE SHEET VINYL. MITER THE CORNERS AND APPLY A BEAD OF SEALANT TO SEAL THE JOINT. 2. PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR OFFICE LIGHTING THE ISSUANCE OF A PERMIT IN , c. BENSON INDUSTRIES (503)907-2200 REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH 1. OFFICE LIGHT FIXTURES: LITHONIA LED FIXTURE.2BLT2 40L ADP MVOLT GZ10 LP835. BASED ON CONSTRUCTION 09 V 0 09 65 19 RESILIENT FLOORING-LUXURY VINYL TILE NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENTAS APPLICABLE. DOCUMENTS AND OTHER d. GRANT SUPPLY (360)887-0647 1. FINISH FLOORING 70 EXTEND UNDER CASEWORK. INCLUDE THE FOLLOWING: 2. REST ROOM-WALL MOUNTED LIGHT FIXTURE-PEERLESS CERRA WALL LED,CRW7L LLP 4FT MSL4 80CRI 35K DATE: 9/8/21 3. DOOR AND RELITE FRAMES SHALL BE TIMELY,OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING 2. INSTALL TILES IN 1/3 OFFSET ASHLAR PATTERN U.N.O. a. DUCTING AND SIZES 190OLMF DARK ZT 120 SCT C210. DATA SHALL NOT PREVENT MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. 3. OFFICE EGRESS LIGHTING:ISOLITE MINI GENIE SERIES LED VERSION LMIGN NM SO-CEILING AND WALL THE Permit / Const 4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, 3. DO NOT WAX OR OTHERWISE SURFACE TREAT EXCEPT CLEANING. b. SUPPLY AND RETURN LOCATIONS AND CFM AT EACH GRILL OR DIFUSER R FROM MOUNT. SEE PLAN FOR EGRESS PATH.USE OF ISOLITE INVERTER AS ALTERNATE TO BATTERY IS HE CORRECTION FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. 4. USE SCHLUTER TRANSITIONS PER FLOORING TRANSITION DETAILS. c. ROOF EQUIPMENT,SIZES AND LOCATIONS ACCEPTABLE. OF ERRORS. OSSC 105,4 REVISION 5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. 09 68 00 CARPET d. UNITS REQUIRING DUCTED SMOKE DETECTION 4. LIGHT SWITCHES:ACUITY CONTROLS PRE SET ALL PRIVATE OFFICE AND CONFERENCE ROOM SWITCHES TO 6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. 1. CARPET SQUARE(24"X 24"NOMINAL) e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH "VACANCY"AND TO TURN ON AT LAST DIM LEVEL.SET TIME-OUT TO MAXIMUM. 1 SITE MAP m. STANDARD WALL SWITCH WITH OCCUPANCY SENSOR-USE WSD NOT TO SCALE Ze 1. 7. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 2 3/4"BACKSET. a. INSTALL IN VERTICAL ASHLAR PATTERN U.N.O. f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS A-1 S. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR 2. USE SCHLUTER TRANSITIONS PER FLOOR TRANSITION DETAILS. g. ZONE DIAGRAM n. WALL SWITCH WITH OCCUPANCY SENSOR AND DIMMING-USE WSXD HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH 09 91 23 PAINTING HVAC DESIGN STANDARDS o. WALL SWITCH WITH DIMMING AND CEILING MOUNTED OCCUPANCY SENSOR-USE SPOD 2. APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT WAREHOUSE LIGHTING SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS INTERIOR: THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: 3. PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL 1. WALLS: 1. 350 SQUARE FOOT PER TON(UNLESS OTHERWISE APPROVED IN WRITING BY PACTRUST). 1. LITHONIA LIGHTING LED BAY LIGHTING IBG15L SEF AFL GND MVOLT 40K 80CRI LAOZU DWH. SAMPLE. 2. LITHONIA LIGHTING ELM LT EGRESS LIGHTING. 4. a. PRIME NEW DRYWALL WITH MILLER PAINT HIGH-BUILD"SUPER SEAL"PRIMER. 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE,AS WELL AS CRITERIA PROVIDED TO PACTRUST BY + z T T T e� �i T O m „ u 9. ALL INTERIOR GLAZING SHALL BE TEMPERED. TENANT PRIOR TO CONSTRUCTION: EXTERIOR LIGHTING � 1" Y „gr`ma19�.•"s Y 10.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STOREFRONT WINDOWS AND DOORS.TOUCH UP b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT _ rj• FINISH FOR AS NEW LOOK. 1204-XX WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER PAINT 170-5-XX S/G a. EXTERIOR EXPOSURE AREAS 1. ENTRY LIGHTING AT RECESSED OPENINGS: LITHONIA LF6N,26DTT LAMP,F60SA RELFECTOR.(EMERGENCY " r----"�-' LATEX ENAMEL. b. INTERIOR AREAS,SIZE AND USE BATTERY PACK OPTION EL) 08 11 13 HOLLOW METAL DOORS AND FRAMES 2. DOORS AND FRAMES: 32 00 00 EXTERIOR IMPROVEMENTS I I . I 6. c. CONFERENCE/TRAINING ROOMS , 1. DOOR: 18 GAUGE, 1'%"THICK,GALVANIZED HOLLOW METAL DOOR,SEAMLESS EDGES,FULLY ENCLOSED AND a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL.SPRAY OR 1. PRIOR TO ANY EXTERIOR EXCAVATION OR BORING,GENERAL CONTRACTOR SHALL OBTAIN AN i 7. SEALED TOP,BONDED POLYSTYRENE OR POLYURETHANE CORE,RUST INHIBITIVE PRIMER. ELECTRICAL ROLLED APPLICATION, d AND 24-HOUR USE.VERIFY NEED FOR A SEPARATE SPLIT SYSTEMT O MAINTAIN A TEMPERATURE. UNDERGROUND UTILITY LOCATE. ¢ ROOM DOORS 42"WIDE. I 8, 2. FRAME: 16 GAUGE,GALVANIZED METAL WITH WELDED CORNERS,2"FACE DIMENSION,5/8"INTEGRAL b. EXISTING HOLLOW METAL-SAND, FILL IMPERFECTIONS WITH BONDO,SAND AND PRIME PATCHES WITH 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL.SPRAY OR ROLLED APPLICATION PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. I STOP,RUST INHIBITIVE PRIMER. VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE c. WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH PAINTER'S ' 3. HARDWARE: 1Y.PAIR,4%X 4%BALL BEARING BUTTS WITH NON-REMOVABLE PINS,SCHLAGE ND53PD RHODES PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX CAULK, ZONES. e -L----- L- DRAWN BY: ENTRANCE LOCK WITH 5-PIN C-KEYWAY KEYED TO PACTRUST BLUE KEY,SURFACE MOUNTED CLOSER,TOP AND FINISH WITH SATIN OIL ENAMEL. 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. DRIP,BOTTOM SWEEP,LOCK GUARD,AND THRESHOLD. ELECTRICAL ROOM USE VON DUPRIN 35A-NL EXIT RIM DEVICE WITH NIGHT LATCH EXTERIOR TRIM. HARDWARE FINISH SATIN CHROME(US26D). d. WOOD-STAIN,SEAL AS REQUIRED,AND VARNISH WITH SATIN VARNISH. 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. R.M.T. 08 43 13 ALUMINUM STOREFRONT DOORS AND WINDOWS 3. CEILINGS: 6. UNITS: LENNOX,TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 7 111111. 1. DOORIWINDOW FRAMES:2"x 4 1/2"OS GLAZED. a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO TONS SHALL HAVE SPECIAL WRITTEN APPROVAL FROM PACTRUST. ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT 6200 OR 4480. 2. DOORS:MEDIUM STILE ALUMINUM SIZE PER PLAN WITH INSULATED,LOW-E NON-REFLECTIVE GLAZING. 7. HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE CONNECTED I 3. DOOR HARDWARE(SINGLE DOOR): SELECT PRODUCTS GEARED CONTINUOUS HINGE,VON b NEW WITH MILLER BOARD I PLASTER PAINT 6200 OR -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE TO A MONITORING STATION WITHIN THE BUILDING. c ---------- -- ----I-- --!Y-1� _8. RO OF TOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITSDUPRIN PULL AN (IN US26D)EXIT RIM DEVICE WITH 1"DIAMETER E ,ALONG BRUSHED STAINLESS STEEL 4. GENERAL NOTES: SHALL BE PLACED SYMMETRICALLY IN A LINE BASED ON LOAD CALCULATIONS BY STRUCTURAL ENGINEER. k OFFSET PULL HANDLE,SURFACE MOUNTED CLOSER,BOTTOM SWEEP,AND THRESHOLD. 4. DOOR(DOUBLE DOORS): SELECT PRODUCTS GEARED CONTINUOUS HINGES,VON DUPRIN 3547A-EO(ONE a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER 9. CURBS: 14"HIGH CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS __ _____ DOOR LEAF)AND 3547A-NL-OP(THE OTHER DOOR LEAF)CONCEALED VERTICAL ROD(IN US26D)EXIT DEVICES SPRAY. BELOW ROOFING. e Aiiiiiiiiiii 1 WITH V DIAMETER BY 10"LONG BRUSHED STAINLESS OFFSET PULL HANDLES,SURFACE MOUNTED b. ALL SURFACES TO BE SANDED BETWEEN COATS, PRIOR TO INSTALLATION OF NEXT COAT. a. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF p AREA OF WORK CLOSERS,BOTTOM SWEEPS,AND THRESHOLD. CONTRACTOR. SEE DIVISION I GENERAL NOTES THIS PAGE. ^ OVERALL BUILDING PLAN c. DURING PROGRESS OF WORK, KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND / ' \ �I�2 5. ELECTRIC STRIKE(WHEN NEEDED FOR ACCESS CONTROL SYSTEM): VON DUPRIN 6300. RAGS AT THE END OF EACH DAY. b. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. /� A-1 1" = 30' ------------------------s _ I Fg,,,ARTINSONIOFFICE OFFICE \ /11\ / \ /1 \ / ^3 I I \/ i \/ I I \/ I\i /n \ i \ i , EGON --REF. LVT CPT CPi 7 WDC§ OF O BREAK W-0- SV ry PROJECT #21540 FES 4'-0- . <� 45• 86•MICRO ^ ' I�I ri i I � / d• II SV CPT d'• \\ J. - rv- 1 WOMEN 4 OPEN OFFICE 1 I V x % i los -, 100 ) _ _ I I '�_'`e•"----- --- i 1 CIRC ':d --- _ -- - - -- �___--- ------ 1 --- II 0 I _ _ 1 =C=�1 I � I `• II I L 1 «LLQ II I MEN 34• LF` I I NEW SIDEWALK _ I 1 i i 106 SV CPT 4'-0- ALIGN WITH BUILDING \ d. WINDOWSASSHWON I' LL 1 O \`\\ Ih i i i `� 6TW> •. . ' i--i--�- —ar--r-�- �� 1 I 1 O M T; -=r �" I I m , • . i I 1,R& I __ \1 I I LE____________ dr____ `70L • • , - 'I /al rte\ = — _ __ __ _ __ __ _ I \ DED. h-L_ I / I • __Irv- J-��I \ 7-- 1 'rte\qP F-7 -79— C13 \\` �I �' j i NEW SIDEWALK IN SAME T a N li I I I I I I I • ' LAYOUT AS REMOVED I I I � , I R\,p 11 I Q 04 rr •r'..•+ I I i 1 I •. I __I I I I JL!__k__L_J__�__IL�.O_ I n ______ _J u:[______m _JI I O O _____ L.i_ II , 1 O Lo ii iiII I \\\ \\\ , .• III III__L'><\ W II v O l I1,, > 11 Si ]C \ .\ •d t--1" "t--r I r=�--r-- -n >� coM //�� J db CN 04 Lo of 4 I \\ \\ WAREHOUSE •a..: t__1�- �ssTi r_i--i• � I®^�i r-�1 1 5 m O O O 7 , I g \ \ g J I/ I N•F"JM - ' -_ I L In Lo v� L=== ===' ---------------- TL -------- V I I I I I - I I F�'--=--- 1 r--------------- 1 1 1 , 1 --�- i I "O 1,11 / it I I II I m 1111 / I, I Y >C I I, � CL i, I I I I i I I III I I I I II I � aJ---- N I I I U i< it 1 11i ffi <` 11 I II I FES ltr--{'-}__"�__-•-'-"t=riY Si�J I �� �� yrr l-=�=1�1 _ i � L_ I '---- ----- ------------- -----------r----r--------� -------------------------� NEW CURB s CEILING DEMO PLAN NEW CURB A-2 1/8" = 1'-0" 2 ____ ____------------- ------------------------- FE _____ ____ I 1 , ice -= N NEW ASPHALT WITH GRADING TO CREATE PROPER DRAINAGE AWAY I FROM BUILDING DEMO PLAN BREAK ,03 2 PARTITION AND POWER PLAN m Fam A-2 1/8rr = 1'-Orr z A-2 1/8rr = 1,-Or, z A3 DEMO NOTES CONSTRUCTION NOTES • REMOVE ALL FLOOR COVERING. RETAIN NEW PAINT THROUGHOUT SHEET VINYL IN RESTROOMS • NEW CARPET TILE V O • DEMO STORE FRONTS AS SHOWN NEW WOC AT ENTRIES • DEMO LIGHTING AS SHOWN _ - - _ • NEW LVT IN BREAK AREA • NEW BASE AND UPPER BREAK CABINET IY FINISH MATERIALS NEW RESTROOM FIXTURES AND FINISHES >_ ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. • ALL NEW AND EXISTING ELECTRICAL FIXTURES TO BE WHITE - U CARPET SQUARE TILE: WOM EN TOUCH UP INTERIOR DOORS w • TOUCH UP EXTERIOR DOORS AND WINDOWS (y _ IWi NEW LED LIGHTING IN OFFICE CPT-1 MANNINGTON COMMERCIAL EXCHANGE 2 COLLECTION-TRANSMIT �� • TUNE UP EXISTING WINDOW BLINDS In ROTARY 13146 / • NEW OVERHEAD DOOR AND HM DOOR co W M 24"X 24"RANDOM V RTICAL ASHLAR LAYOUT-EAST!WEST 3 - 5,-0 6 • NEW STORE FRONT DOOR i W Q Z O a0 � WALK-OFF CARPET TILE I 1 i (n O Ix WOC MOHAWK GROUP TUFF STUFF II-STEP UP II U) m O 989 OBSIDIAN, DIRECT GLUE e k3 / 84•-T i W Ix USE MOHAWK M700 ADHESIVE. (M95.0 IN HIGH MOISTURE AREAS) ® 1 `-J z a p LUXURY VINYL TILE I� m W LVT MOHAWK GROUP MATUTO PLUS STONE C0135 926A AGREEABLE GREY STONE i Q Z In SHEETVINLY _ CONSTRUCTION LEGEND -0 0 04 LU LU SV MANNINGTON COMMERCIAL SERENITY COLLECTOPM 0 O W Y EPHEMERAL C2022 q 15 N O Lr' 969 RELAXATION a / e\ \ EXISTING TO REMAIN I BASE ro I S•-0- \ ______ EXISTING TO BE REMOVED I DATE: 9/8/21 RF FLEXCO 4" FLAT RUBBER BASE,071 BLACK/BROWN,AT ALL CARPET AREAS. e RC FLEXCO 4"COVE RUBBER BASE,071 BLACK/BROWN,AT ALL HARD SURFACES. 3 NEW WALL WITH INSULATION Permit / Const MEN\\\ �� A3 NEW WALL WITH INSULATION AT RESTROOMS REVISION PAINT: los _ PT-1 MILLER 110-4-10 ACRO PURE ULTRA-lOW VOC 0017 LUNA MOON, SATIN LATEX. ® a NEW WALL TO BUILDING STRUCTURE WITH INS.TO 12"ABOVE CEILING GRID (AT ALL RESTROOMS USE MILLER 320-5-10 SEMIGLOSS ACRINAME L) PT-3 MILLER 130-1-05 PERFORMANCE PLUSS-FLAT-MIX IXX79W(WAREHOUSE WALLS) A53 NEW EXTERIOR WALL 1. LAMINATE: 2. PL-1 FORMICA 5881-58 CHOCOLATE WARP ALL FACES � DUPLEX RECEPTACLE a ELECTRICAL PANEL PL-2 FORMICA 6920-58 MINERAL SPA COUNTER,B.S.AND SELF-EDGE. 5 RESTROOM PLAN 3• CAB PULLS 626 BRIGHT CHROME A-2 1/4" = 1'-0" Z zo FOURPLEX RECEPTACLE POWER POWER J-BOX D� DEDICATED OUTLET ® FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA 4• IDOOR SCHEDULE 6V EXISTING ELECTRICAL TO REMAIN FEa FIRE EXTINGUISHER IN RECESSED CAB. 5• DOOR DATA FRAME DATA _ HARDWARE __ / FLOOR MONUMENT W1 SERVICES SHOWN FEs FIRE EXTINGUISHER-SURFACE MOUNTED MARK DOOR SIZE THK CORE VENEER FINISH HAND TYPE FINISH DEPTH FIRE RATING ACTION MANUFACTURER FINISH FUNCTION REMARKS MARK O 100 3'-O"x 8'-0" 1 1/2 - ,LGLASS . ,GLASS 4Right ALUMN BLDG.ST 5" - PANIC BAR/PULL/CLOSER VON DUPRIN 626 BRUSHED CHROME 3547A 3547A-NL NIGHT LATCH 100 SPECIAL OUTLET 0T THERMOSTAT 7' .......-... - - ---- -...--- -...- ---- - ___ .......... ......_. ......-._ -- 105 3 0x_9'-0" 1 3/4 SC- !OAK WATCO Right TIMELY SMOKE WHITE 4 7/8" - LEVER/LOCK - SCHLAGE 626 BRUSHED CHOME ALX40S - 105 TEUDATA MUD RING WITH PULL STRING ' x --- --.---- ,106 3-0"x 9'-0" 1 3/4 SC OAK WATCO 'Left TIMELY SMOKE WHITE 4 7/8" -- LEVER/LOCK SCHLAGE 626 BRUSHED CHOME _ALX40S 106 'x,107 3'-O"x 9'-0- 1 3/4" 1 SC OAK WATCO Left TIMELY SMOKE WHITE 6" -- LEVER/CLOSER SCHLAGE 626 BRUSHED CHOME .NDX10S IVES DOOR HOLDER 107 CEILING LEGEND --- 11 DRAWN BY: R.M.T. FINISH SCHEDULE 2X2LEDBLTCEILINGFIXTURE $ STANDARD SWITCH 4 REFLECTED CEILING PLAN m _-..------- ---- .-___— ._ ______ WALLS CEILINGS ._--- REMARKS RM# Z IRM# NAME FLOOR BASE ---- ------T --- -� -- -- --- - A-2 1/B" = 1'-O° NORTH EAST SOUTH WEST MATERIAL HEIGHT ® OCCUPANCY SWITCH 1100 OPEN OFFICE CPT-1 /WOC 4"RF E WW-PGWB E PGWB EPGWB E-PGWB E-SAT 9'-0" i- 100 LED HIGH BAY WAREHOUSE FIXTURE CEILING NOTES _ _..___ ._......... -_.. OCCUPANCY SENSOR ON EACH FIXTURE 181 CEILING OCCUPANCY SENSOR 1101 OFFICE CPT-1 4"RF E PGWB IE PGWB jE-PGWB E-PGWB E-SAT 9'-0 - 101 • TUNE EXISTING GRID - ® REPLACE DAMAGE OR STAINED TILE FROM PTR INVENTORY 102 OFFICE CPT-1 4"RF 9-PGWB _E PGWB E PGWB E-PGWB E-SAT 9'-0 1 - 102- WALL MOUNTED EGRESS LIGHT FIXTURE SUPPLY DIFFUSER �--._... 103 BREAK LVT 4"RC PGWB EPGWB IE PGWB E-PGWB E-SAT 9-0 - 103 1.___ ...... _. ---. _. _ ..... RETURN DUCT ,104 CIRC CPT-1 4"RF PGWB __ EPGWB PGWB PGWB ESAT 9'-0 - 104 RECESSED LED LIGHT( ) ® NEW LED LIGHTING IN WAREHOUSE TVP' • CLEAN/REPLACE HVAC GRILLS AS NEEDED A� 2 105 WOMEN SV 4"RC PGWB E PGWB E-PGWB E-PGWB E-WBC 9'-0 - t05 ® EXHAUST FAN -- -- - -- - • ADD RECESSED LED FIXTURES AT NEW RECESSED ENTRY 106 MEN SV 4"RC PGWB EPGWB E-PGWB E-PGWB E-WBC 9'-0" _ 106- y EXIT SIGN • ADD BUILDING STANDARD EXTERIOR WALL FIXTURE OVER NEW RECESSED ENTRY - -- 107 WAREHOUSE SC 4-RC PGWB E-PGWB E-PGWB ETR 14'-0" - 107 • ADD ROOF AND WALL INSULATION AS NEEDED IN WAREHOUSE AT RECESSED INFILL LOCATIONS DETAIL GENERAL NOTES: 2' 1. FOR WALLS UP TO 14'-0"TALL, USE 3625125-30 MTL. STUDS @ 24"O.C. UNLESS EXISTING CONC.WALL — " 301.. ao ' a" MARTIN W.HANSON CALLED OUT OTHERWISE IN DETAIL. USE 362T 125-30 MTL.TRACK. - asoy" 3o 2 X 6 P.T.TOP PLATE Q� 2. FOR WALLS OVER 14'-0"TALL, USE 6005125-33 MTL. STUDS @ 16"O.C. UNLESS COAT JAMB AND HEAD WITH FLUID a -� CALLED OUT OTHERWISE IN DETAIL. USE 60OT125-33 MTL.TRACK. APPLIED WRB o o PL-1 3. ALL WALLS:ATTACH BOTTOM TRACK TO FLOOR WITH POWDER DRIVEN 3/8" MIN. ROD AND SEALANT z �aCLACKAMAS,OREGON ANCHORS AT 24"O.C. _� "J" FLASHING W/3"VERT. LEG, LAB FLUID a ADJ.SHELF 4. IN WALLS WITH ACOUSTIC INSULATION, SET BOTTOM TRACK IN BED OF SEALANT. APPLIED WRB OVER VERT. LEG 2"MIN. PROVIDE HC SIGNAGE FOR ALL �l' BED FLASHING IN SEALANT 2" NEW AND EXISTING HC RR'S J M 5. FOR WALL FINISHES, FLOOR FINISHES AND WALL BASE TYPE, REFER TO INSTALL SEALANT @DROP. �� KROY#2835207 BLACK(MEN) w MICRO SHELF AT 18" U DEEP WITH 2" - -------- - - ADJ.SHELF = PROJECT FINISH SCHEDULE. KROY#2835209 BLACK(WOMEN) - -------- - - -- ---- POWDER DRIVEN ANCHORS _ OPEN RADIOUBACK PROJECT #21540 F N OPEN BACK STRUCTURAL SUPPORTING CALCS: r r 5/8"GYP BOARD y w I ADDITIONAL SWITCH LL 2% 01G PL-1 ALL FACES BOBRICK PL-1 VAPOR BARRIER z GANG LOCATION B-262 1. POWERS 0.300 HEAD(3/4" EMBED)0.145 SHANK DIAMETER - p- �� z q" 1" 1 1 1 3" ALLOWABLE SHEAR=70 LBS 5/8" MOISTURE REISTANT EXT.GYP BRD o 0 0 30� 151 30z" 154' a V 2. 12'-0"TALL WALL WITH CODE REQUIRED 5 PSF MINIMUM LATERAL FLUID APPLIED WRB (WIND) LOAD SHEAR=5 PSF" 12'-0"/2=30 PLF 1/2"AIR SPACE WITH PLASTIC FURRING STRIPS = = U 2�I— 4_4 3. ANCHORS AT 16"O/C CEMENT BOARD SIDING w ELECTRICAL > F z Z — — — PL- SHEAR=30 PLF' 16"/ 12"=40 LBS R-19 BATT INSULATION \ OUTLET OR w U) 9 4. UNITY CHECK 6" MTL. STUDS. J-BOX _j U) 0 U) U 40 LBS/70 LBS=0.57< 1.0 OK — ADA INK — L 6 IN METAL STUD TRACK SILL PLATE. SET IN BED �a O C7 w — — Q 5. ANCHORS AT 24"O/C OF SEALANTN ------------ SHEAR=30 PLF "24"/12"=60 LBS � v �o — — SEALANT EACH SIDE UNDERCUTDOORAS C O 6. UNITY CHECK FINISH FLOOR r REQUIRED SH CLEAR PL-1 O O "Z" FLASHING W/4"VERT. LEG, LAP FLUID APPLIED FLOOR FINISH PL-1 BASE M 60 lbs/70 lbs=0.86 < 1.0 OK " WRB OVER VER. LEG 2" MIN. BED FLASHING IN SEALANT. INSTALL SEALANT @ DRIP. C 1 GENERAL NOTES 5 EXTERIOR WALL DETAIL s MOUNTING HEIGHTS A 3 -0 CABINET ELEVATION 1 (a " N A-3 SCALE 1 = 1 -0 A-3 SCALE 1 - 1 -0 SCALE 1/2 1 -0 1/2" = 1' " BR AKE 03 = a EQ. EQ. 0 O 20 GA 3 5/8" METAL STUD BRACING TO ROOF STRUCTURE AT 10'-0"OC TO BUILDING STRUCTURE OW CD 00 Lo 2'-0" 2'-0" ABOVE FOR WALLS LONGER THAN 12'-0"WITHOUT N c: 0 cep I` INTERSECTION WALLS. FASTEN EACH END WITH U Z V V L (1)#8 SHEET METAL SCREW WALL MOUNTED LIGHT '� g co cc TYPICAL STUDLO of M M SOUND INSULATION 4'CENTERED C � 0 00 OVER WALL 24' G d V SUSPENDED CEILING 40' BLOCKING TYPICAL AT FASTENING POINTS. 0 TYPICAL TRACK 36" 6" 12" 42" p1 MTL. STUDS. INSTALL STUDS WITH // m 5/8" GYP. BRD. BOTH SIDES SAME DIMENSION (10" MIN.) FOR BRIDGING 18" ao h z = ALIGNMENT ___ ___________A_Q_U_A_T_O_U__H_W_AIN_S_C_O_TT 36" aO CENTER LINE OF STUD A UATO GH WAINSCOTf w O w x cel w � U) UL 3-1/2" BATT INSUL. IN SOUND ATTENUATION WALLS +' �. POWDER DRIVEN � �'.,,,� 'r ANCHORS AT 24"O.C. �♦ (1)#10-16 SCREW a BOTTOM TRACK. ♦♦♦ PER STUD FLANGE `v o M AT WALLS WITH 21" ACOUSTIC INSULATION, ' FINISH FLOOR-TOP OF SLAB SET STUD TRACK IN A CONTINUOUS BED OF v FI - I I I SEALANT. 18" 2 WALL SECTION WITH SOUND INS. 6 WALL BASE DETAIL 14 RESTROOM ELEVATIONS F A-3 SCALE 1" = 1'-0" A-3 SCALE 3" = 1'-0" A-3 1/2" = 11-0.1 WOMEN 105 10' MAX SPAN 5/8" PLYWOOD DECK WITH SHEET EQ. EQ. ol METAL SCREWSBATT INSULATION. 8005250-54 METAL STUDS AT 16" O.C.,ALIGN WITH WALL STUDS NL WALL MOUNTED LIGHT METAL CEILING STUD LOAD CHART FAM MAX.SPAN 11 MAX.SPACING 16" 24" MAX.POINT LOAD 375 LB/STUD ROOF DECK 5/8"TYPE X GYP. BD. SCREW OR BEAM 40" ATTACHED 5/8"GYP. BD. CENTER LINE OF STUD 42^ 12" 6" 36" U o 2 SUSPENDED CLG ASSEMBLY \\ Q z ao 18" = __ 36" - AQUATOUGH -AINSCOTT AQUATOU H W NI 9--- ---------- ---- ------ ---------- --- LU Ill a) 0 362S137-33 METALSTUDS 45" N = LL U- AT 16" O.C. :.,r t'-;H::...", r.:l;<:. •r ... :'.:. r ..YupFa. 5/8"TYP.WR ••: .•��':.•. Lo GYP.BD. od W 20 GA 3 5/8" METAL STUD BRACING Q Z o BOTTOM TRACK. - TO ROOF STRUCTURE AT 10'-0" • 0_ 0 O i; OC W/(2)#8 SHEET METAL f c m SCREWS AT EACH END. BRACING o o W 0' o ACOUSTIC SEALANT IN 1/2"SPACE, F TO BE PROVIDED WHERE DISTANCE Y, Y M Z d 0 EA SIDE. BETWEEN PERPENDICULAR INTERSECTING FINISH FLOOR-TOP OF SLAB WALLS OR HORIZONTAL BRACING 21" d U BETWEEN WALLS EXCEEDS 12'-0"OC w r m REST ROOM SIDE FFICE SIDE p CL J_u0-7 0 4 7/8"- -0 0 cV 18" O WW 00 Y 3 RESTROOM WALL SECTION3 WALL BRACING DETAIL A 3 RESTROOM ELEVATIONS CV o lg A-3 SCALE 1 = 1 -0 SCALE 3 - 1'-0" MEN 106 DATE: 9/8/21 BLDG. FLOOR OR ROOF STRUCTURE Permit / Const SEALANT IN 1/2" SPACE, EA SIDE. REVISION DEFLECTION CHANNEL Lu 4 3-1/2" BATT INSUL. 1 MTL. STUDS. 2. 3. 4. 0 SUSPENDED CEILING 5. 6. 5/8"GYP. BD. 7. BOTH SIDES SCREW ATTACHED 8. CENTER LINE OF STUD z = DRAWN BY: a w R.M.T. w = U) 0 U_ BOTTOM TRACK SEALANT IN 1/2"SPACE, EA SIDE. FINISH FLOOR-TOP OF SLAB A� 3 i a OFFICE TO WAREHOUSE SEP. WALL A-3 SCALE 1" = 1'-O"