Loading...
Plans (82) FPS2021 -00110 CITY OFTIGARD RECEIVED SIGNED BY: Approved...................................................[VIS HALBERG, MARK W Contitionally Approved..............................I ) SEP 14 2021 OREGON LICENSE For only the work as described in: t;ITY OF TIGARD #22907.1 PERMIT NO. 0u11c> See Letter to: Follow.................................. j 3UILDING DIVISION Attach.................................. Job Address: (c43fo SQ OCA-- k-yMb By: Date: q OFFICE COPY LEGEND Cr SYM DESCRIPTION MODEL NUMBER BACK BOX F_AC P FIRE ALARM CONTROL PANEL EST i0500GD 28"H X 15.75"W X 3.85"D MMIMEMR FAA REMOTE ANNUCIATOR EST RLCD-C 5.625"H X 8.5"W X 1.5"D ��$ 4" SQUARE STANDARD BOX 6000 NE 88TH Street,Suite 8103 NAC# NAC EXPANSION PANEL EST BPS6A 17"H X 13"W X 3.5"D Vancouver,WA 98665 Tel: (360)816.0484 Fax: (360)816-0482 MFC MULTIPLE 1/0 MODULE CABINET EST MFC-A/MP2L(2EA.) 8"H X 14'W X 3.5"D W/SIGA MOUNTING PLATES FF MANUAL PULL STATION EST SIGA-270/278 1-GANG STANDARD ELECTRICAL BOX EXG. MECHANICAL Q2 PHOTOELECTRIC SMOKE W/BASE EST SIGA-PD/SIGA-SB4 4" SQUARE OR OCTAGON STANDARD BOX ROOM ? ACTIVITY ROOM 5TORAGE/MECHANICAL : - - - - - QH HEAT DETECTOR W/BASE EST SIGA-HFD/SIGA-SB4 4" SQUARE OR OCTAGON STANDARD BOX 046 ROOM 046 15cd H ADDRESSABLE HVAC DUCT DETECTOR EST SIGA-SD/EST SD-T##(##=8,18, FURNISHED WITH UNIT FOR SURFACE O EXG. SPA O (N) F EOLR W/AUX. RLY & SAMPLING TUBE 24,36,42,60,78 OR 120, VERIFY) MOUNT ON DUCTWORK j N1-2 0 REMOTE DUCT DETECTOR TEST EST SIGA-SD-TRM (FOR ALL INDOOR 1-GANG STANDARD ELECTRICAL BOX- CLG _ STATION (LOOP POWERED) DETECTORS) MOUNT WAN 5' OF DETECTOR m. FV SITE VAULT TAMPER SUPPLIED BY OTHERS ©F SPRINKLER FLOW SWITCH SUPPLIED BY OTHERS TS SPRINKLER TAMPER SWITCH SUPPLIED BY OTHERS ` - ® DRY PIPE LOW AIR ALARM SUPPLIED BY OTHERS HA DRY PIPE HIGH AIR ALARM SUPPLIED BY OTHERS EXG. POOL - FITNESS ROOM OUTSIDE WATERFLOW BELL SUPPLIED BY OTHERS 120V CONNECTION REQUIRED NDOOP 75cd OUTDOOR CC1S SYNCHRONIZATION SIGNAL MODULE EST SIGA-CC1S 4" SQUARE 2.25" DEEP BOXLOUNGE E0144 1 ®144 (N) F FC-C-1 1 ADDRESSABLE SIGNAL MODULE EST SIGA-CC1 4" SQUARE 2.25" DEEP BOX CR 75cd ADDRESSABLE RELAY MODULE EST SIGA-CR 4" SQUARE W/1-GANG MUDRING � i CR ADDRESSABLE RELAY MODULE EST SIGA-CRH -HIGH POWER 4" SQUARE W/1-GANG MUDRING (N) F H EXG. POOL/ Fc­T1 ADDRESSABLE INPUT MODULE EST SIGA-CT1 4" SQUARE W/1-GANG MUDRING EOU PM. 046 ROOM Fc-T-21ADDRESSABLE DUAL INPUT MODULE EST SIGA-CT2 4" SQUARE W/1-GANG MUDRING O(X) (CO L75cd T (CONT'D) s TD) LOBBY tl WALL HORN/STROBE UNIT EST GENESIS G1-HDVM 1-GANG STANDARD ELECTRICAL BOX j AREA OF DEMOLITION N.I.C. t 003 15cd 003 NEW �F WALL STROBE UNIT EST GENESIS G1-VM 1-GANG STANDARD ELECTRICAL BOX F O2 (R) PUBLIC LOUNGE VESTIBULE x. DEVICES WALL HORN UNIT WHEELOCK MIZ-24S 4" SQUARE DEEP BOX RE5TROOM5 N.I.C. _ LOBBY EXISTING ' cd 4 CEILING HORN/STROBE UNIT EST GENESIS GCAVWF 4"SQUARE STANDARD BOX PUBLIC N.I.C. EXG. EXERCISE CORRIDOR - RE5TROOM5 OLLABORATION cd CEILING STROBE UNIT EST GENESIS GCVWF 4"SQUARE STANDARD BOX ROOM N.I.C. SPACE c � F cd LF WALL HORN/STROBE UNIT EST GENESIS GIAVWF 1-GANG STANDARD ELECTRICAL BOX A 007 007 WALL STROBE UNIT EST GENESIS G1VWF 1-GANG STANDARD ELECTRICAL BOX O Cd 5K O (R) 30cd O EOLR F JUNCTION BOX - 2-GANG ELECTRICAL BOX N1-2 0 MFC ELEVATOR 1/0 MODULE CABINET W/SIGA EST MFC-A/MP2L(2EA.) 8"H X 14"H X 3.5"D MOUNTING PLATES LV 1 ORIGINAL POOL AREA FLOOR PLAN - FIRE ALARM � LV 1 CONVERSION POOL AREA FLOOR PLAN - FIRE ALARM m ELEVATOR TO ALTERNATE FLR RELAY EST SIGA-CR VIA MFC-A CABINET 2 1/8"=1'-0" �JJ 1/8"=1'-0" m ELEVATOR TO PRIMARY FLR RELAY EST SIGA-CR VIA MFC-A CABINET (X)= DEMO EXISTING, RETURN TO OWNER FOR SPARE PARTS (N) = NEW DEVICE IN NEW LOCATION 0 5' 10' 15' 0 5' 10' 15' (R) = REPLACE DEVICE WITH NEW SIT ELEVATOR SHUNT TRIP RELAY EST SIGA-CR VIA MFC-A CABINET ALL OTHER DEVICES ARE EXISTING TO REMAIN O F/H ELEVATOR FIRE HAT BLINK RELAY EST SIGA-CR VIA MFC-A CABINET ® ELEVATOR SHUNT TRIP POWER MONITOF EST SIGA-CT1 VIA MFC-A CABINET KH KITCHEN HOOD INPUT EST SIGA-CT1 4" SQUARE W/ 1-GAND MUDRING FSD FIRE SMOKE DAMPER BY OTHERS VIA EST SIGA-CRH - NOT ALL SYMBOLS USED Q W COURTYARD BY MARRIOTT - TIGARD OR � � Q CONDUIT TYPE DEVICE TAG ABBREVIATIONS EST EDWARDSiO500GD SERIES FIRE ALARM CONTROL PANE(F yP#0 W1eERYOChLCCULATION Volts Nin Volt a Drop Drop% TOTAL TOTAL INDICATES NAC CIRCUIT INITIATING DEVICES cd CANDELLA DEVICE Distance Gauge Per Total at Volts EOL EOL STANDBY ALARM STANDBY ALARM Q WIRING 1,### EOLR END OF LINE RESISTOR MODEL Desc QTY. Feet # Foot Ohms Eol R 'd Method Volt A A A A EOL END OF LINE 0 N - - - - - - - INDICATES VOICE EVAC. L DEVICE/ADDRESS NUMBER FSD FIRE/SMOKE DAMPER 10500 FACP,250pt,4 NACs Red, 1200 1 0.17200 0.26700 0.1720 0.2670 = N SPEAKER WIRING SLC LOOP NUMBER SD SMOKE DAMPER SA-DACT Dual Line Dialer 1 0.04100 0.04100 0.0410 0.0410 INDICATES SLC LOOP WIRING (NOT SHOWN) VR VANDAL RESISTANT RLCD-CR LCD Ann w/common LEDs&Ctrls, Red 1 0.09900 0.11500 0.0990 0.1150 CY 0) W WATT W CIRCUIT NUMBER ` a/ NOTIFICATION WP WEATHERPROOF NAC CKT#1 300 FT #14 3.07 0.921 18.005 16.00 2.395 11.74% Ckt.Am s= 1.300 v+ O - - - INDICATES 24VDC POWER N#-# WG WIREGUARD SUPPLY WIRING EXISTING(ESTIMATED) 1 1.3000 1.3000 5 (D) EXISTING TO BE DEMOLISHED O Q - - - - INDICATES MISC. FIRE ALARM (E) EXISTING TO REMAIN PANEL NUMBER NAC CKT 92( EW DEVICES IN BOLD) 386 FT #14 3.07 1.185 17.172 16.00 3.228 15.82'h Ckt.Amps-- 1.362 U WIRING (R) EXISTING TO BE RELOCATED GIF-HDVM Han-Strobe, 15cd,WaN Hi db 1 0.1620 0.1620 O O MZ-25 Horn,Hi db 1 1 0.0260 0.0260 000 Gt F-HDVM Han-Strobe, 15cd,WaM Hi db 1 0.1620 0.1620 c _ MZ-25 Horn,Hi db 1 0.0260 0.0260 MIZ-25 Horn, Hi db 1 0.0260 0.0260 MZ-25 Horn, Hi db 1 0.0260 0.0260 G1F-HDVM Han-Strobe, 15cd,Wall Hi db 1 0.1620 0.1620 MZ-25 Horn,Hi db 1 0.0260 0.0260 MZ-25 Horn,Hi db 1 0.0260 0.0260 MZ-25 Horn,Hi db 1 0.0260 0.0260 G1F-VM Strobe 15cd,Wall 1 0.1250 0.1250 G1 F-HDVM Horn-Strobe, 15cd,Wall Hi db 1 0.1620 0.1620 G1F-VM Strobe 15cd,Wall 1 0.1250 0.1250 H GIAVWF Horn-Strobe, 15-75cd,Wall Hi db 1 0.0550 0.0550 a W G1VWF Strobe, 15-75cd,Wall Hi db 1 0.0320 0.0320 H GCVWF Strobe, 15-115cd,Cell.Hi db 1 0.0450 0.0450 GCAVWF Horn-Strobe, 15-115cd,Cell.Hi db 1 0.0750 0.0750 GUES R OMS W GCAVWF Horn-Strobe, 15.115cd,Cell.Hi db 1 0.0750 0.0750 Z 0 O NAC CKT#3 300 FT #14 3.07 0.921 18.005 16.00 2.395 11.74% Ckt.Am s= 1.300 P EXISTING(ESTIMATED) 1 1 3000 13000 B.O.H. B.O.H. WORK THIS a! AREA U Q W NAC CKT#4 300 FT #14 3.07 0.921 18.005 16.00 2.395 11.74°k Ckt.Am s= 1.300 W EXISTING(ESTIMATED) 1 13000 13000 B.O.H. p CURRENT TOTALS(A)--> Nac Ckts= 5262 0.312 5.685 • N STANDBY HOURS REQUIRED 24 ° ° toil ALARM SOUNDING MINUTES 5 Voltage Drop Calculation Notes: W TOTAL SYSTEM STANDBY A 0.312 1) Calculations use the NFPA70(NEC 2014) LOBBY Co TOTAL SYSTEM ALARM A 5.685 Wire Resistance Values for 167 Degrees 0 TOTAL SYSTEM STANDBY A/H 7.49 Fahrenheit[See Chp. 9, Table 8]. w o TOTAL SYSTEM ALARM A/H 0.47 2) Calculations are using the manufacturer's MINIMUM A/H BATTERY REQUIRED 7.962 U.L. Max. current values for Notification WITH 20% SPARE CAPACITY A/H 9.554 Devices. MTG. DRAWN BY: SHAWN B. ROOM BATTERIES PROVIDED AT 12VDC AH 2 12 AH Job Contact: NATHAN B. Job Number: 511021 GUES R OMS SHOP DRAWINGS FLOOR PLAN FIRE ALARM KEY PLAN NO SCALE FA2000