Loading...
Plans (71) FPS2021 -00081 OFFICE COPY VED JUL 1 2 2021 CITY OF T GARD WOOD NAILER ROOF DECK BUILDING [VISION k' FOR FLANGES > 2- WIDE 3/8' SIDE HANGER ROOF DECK ' FR FLANCGFS < 2' WIDE MATE FOR WOOD METALFDECK R�� 3/8"x ALL THREAD X-PRESS SCREW n c o MATE B R WOOD HANGERTM ROD FIG. 200 ADJUSTABLE 3/8'x ALL RING HANGER THREAD ROD f 5 }---------.----'--------- .-- '-- __ _ -. _- _. s 3/8'x ALL THREAD FIG. 200 ADJUSTABLE) — R ROD a RING HANGER ! I O• ® '�T�jI7'O• FIG. 200 ADJUSTABLE NOTE: I P R "I ' t i RING HANGER BAR JOIST 1. MODEL XP20 SUPPORTS 2' PIPE AND SMALLER IN 2. MODEL XP35 SUPPORTS 3-1/2' PIPE AND SMALLER IN 22-20 GAUGE STEEL I i R y i 18-16 GAUGE STEEL I #5 HANGERMATE #6 HANGERMATE #22 SAMMY X-PRESS SCREW i0 _ A I1 R i j • R PROVIDE EITHER I I II— A FLEXIBLE SPRINKLER .. HEAD OR 2-INCH L , -1 �rFICE R � -..-i 1 P Q•1 t �Q I [ I ` OVERSIZE IINTERP RINGS R1 I , 6 El ai- BRANCHLINE 1 PLEASE PROVIDE VARIES 0• ; t R - ® R i 1 i n ; COMPLETED NFPA 13 IAL AND �.. R @R N , Ir- 0 MATER , (Je��® . RCERT FICATE AT T V I I I I O tON ti, ` P I I I , , p FINAL INSPECT I I , I I A RRI; 0 4.Ek �Ci��n .,y- ; N 1 ; �`6 ! ; ; R I O l7 1 ® BRANCHLINE -- ti 1 I I 1 p I 1 QR ' T 1x ° a ° RS O s ' i ~VARIES 1 OFFICE COPY 6 c.o.J. CITY OF TIGARD,,, y.l P R A R,.; - 1 }_._ 1 .. -,L-1 • - -1_ VARIES REVIEWED FOR CODE COMPLIANCE a_t {$ - - =- �. ` 1 E ; .Fs O Approved: -I\/I R ° F-----21- ----- f-�-- --- 1- --- ---1 ------- -. -- I o OTC: ow Permlt#; 12 - n A i - c Oa u .. ,� R �„� C - i� i - _ I o Address: *),,I L.7 n PG�j -jwv t�lLlLll i 1 1� 1 11�� Suite#i ,R 'I RX ! • E Dam ° �' r' �-- P to R ;01 P `.� I 1 � -- 1_ -® I ; O DROP CEILING I - i E i -R--- RQ li-�c�J R A � 1 1 I 1 DROP DETAIL DROP DETAIL I E 1 1 I Q ' _ •� A Rif 1 , SE 1 [ al T R E �, E E E 1 I E E - - - r4 k L. E E E E R '� , '1•J -- - -� 1.DASHED PIPING IS EXISTING. O 2.EXISTING UPRIGHTS TO REMAIN. p®---I A=ADD Iraiv.ac ; I �, ex_ c, , R=RECUT RELOCATE YI I 'I P � / -,I E� � - � - FFIc- E=EXISTING P=PLUG R RO ; (`�• R i � � P I _ e O HATCHED AREAS ARE NOT O IN SCOPE R WORK. REFLECTED CEILING NOTES: 1. ADD/RELOCATE SPRINKLERS AS NEEDED FOR NEW TENANT IMPROVEMENT. 2. VIKING TO START AT EXISTING BRANCH LINES. 3. ALL NEW PIPING TO BE BLACK SCHEDULE 40 WITH C.I. FITTINGS. 4. EXISTING PIPING, HEADS, AND HANGERS TO REMAIN UNLESS OTHERWISE NOTED. 5. VIKING'S SCOPE DOES NOT INCLUDE ANY RESPONSIBILITY, EITHER WRITTEN R IMPLIED, FOR THE CONDITION OR CURRENT CODE COMPUANCE OF ANY EXISTING SPRINKLER SYSTEM EXCEPT AS MODIFIED BY VIKING. THIS DRAWING IS THE PROPERTY OF VIKING AUTOMATIC SPRINKLER COMPANY. IT IS SUBMITTED IN CONFIDENCE AND IS NOT TO BE DISCLOSED OR UTILIZED WITHOUT THE WRITTEN PERMISSION OF VIKING AUTOMATIC SPRINKLER CO. REVISIONS ABBREVIATIONS GENERAL NOTES WATER FLOW INFO SPRINKLER SYMBOL DESCRIPTION WET STAMP PROJECT: MARK BY DATE DESCRIPTION AFF- CENTERLINE ABOVE FINISH FLOOR 1.ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS STATIC: SYM STYLE MFG RESPONSE THD 'K" TEMP SIN# FINISH ESCUTCH. WRENCH CITY �■T W ESTS I D E SURGERY ATB -CENTERLINE ABOVE TOP JOIST APPROVED. RESIDUAL: CENTER BOB-CENTERLINE BELOW BOTTOM OF BEAM SEATTLE BOISE BOD-CENTERLINE BELOW BOTTOM OF DECK 2.PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER& FLOWING: Q• SSP VIKING QUICK 1/2' 5.6 155° VK302 WHITE E-1 CHR 21475W/B 58 PORTLAND FIRE PROTECTION POCATELLO BOP-CENTERLINE BELOW BOTTOM OF PURLIN DIMENSIONS SHOWN THUSLY(1-6)WHICH ARE END TO END. @ 20 PSI: { CONC PEND VIKING QUICK 1/2' 5.6 155' VK462 STD WHITE 14031 4 LONGVIEW MEDFORD 13240 SW PACIFIC HWY BOJ- CENTERLINE BELOW BOTTOM OF JOIST 3. PIPING, HANGERS,AND EARTHQUAKE BRACING SHALL BE IN PORTLAND OR 97223 BTJ -CENTERLINE BELOW TOP OF JOIST ACCORDANCE WITH NFPA PAMPHLET NO. 13,APPLICABLE EDITION. DATE: VIKING AUTOMATIC SPRINKLER COMPANY (i - CENTERLINE OF PIPE,COLUMN,OR BEAM LocnrloN: 3245 NW FRONT AVENUE COJ-CUT ON JOB 4.JOINING OF PIPE AND FITTINGS,THREADED AND WELDED SHALL FO - FIELD ORDER BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13. INFO FROM: PORTLAND, OREGON 97210 • 24 hrs. (503) 227-1171 CPLG-COUPLING 5.OWNER TO MAINTAIN 40'F MINIMUM IN LOCALITIES SUBJECT TO PUMP GPM: PUMP PSI: TYPE: OREGON CCB#64837 METRO LIC#2816 .WASHINGTON LIC#VI-KI-NA-S373NT MAIN FLOOR T 1 FLEX-FLEXIBLE COUPLING FREEZING PROTECTED BY A WET PIPE SPRINKLER SYSTEM AND IN GOE-GROOV GROOVED DED OUTLET-GROOVE ONE END ENCLOSURES FOR DRY PIPE, DELUGE,OR ANY OTHER VALVES APPROVING AGENCIES CONTRACT WITH: DWG RELEASE DATES: GxG-GROOVE x GROOVE CONTROLLING WATER SUPPLIES. COORDINATION- Date Drawn: Drawn By: SHEET: 1 OF GxP-GROOVE x PLAIN 6.STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SSP EXISTING 1/2' 5.6 155' - WHITE - P.E./PERMIT- 06/24/21 BATEMAN F P 1 ■ 1 POL-THREADED WELDED OUTLET SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER TOTAL SPRINKLERS SHOWN ON THIS SHEET 62 FABRICATION- TOE-THREAD ONE END AND/OR HIS STRUCTURAL REPRESENTATIVE. CONSTRUCTION- Scale: Job No. TxG- THREAD x GROOVE TOTAL SPRINKLERS REQUIRED ON THIS CONTRACT 62 AS-BUILTS- 1�8" = 1'-0" OPC-1058