Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (72)
FPS2021 -00037 OFFICE COPY VALIDITY OF PERMIT RECEIVED THE ISSUANCE OF A PERMIT Fire Alarm Plan - T T S D Mary Woodward Elementary BASED ON CONSTRUCTION MAR 2 3 2021 DOCUMENTS AND OTHER CITY OF TIGARD DATA SHALL NOT PREVENT 12325 S E Katherine St. L. THE CODE OFFICIAL FROM BUILDING DIVISION REQUIRING THE CORRECTION Tigard, OR 97223 OF ERRORS. OSSC 105.4 - - - - FIRE ALARM SYMBOLS / BACKBOX INFORMATION APPLICABLE BUILDING CODES SCOPE OF WORK SYMBOL QTY PART NO. MANUF. DESCRIPTION MOUNTING BOX INSTALLATION NOTES 2019 OREGON STRUCTURAL SPECIALTY CODE (OSSC) BUILDING DESCRIPTION: EXISTING ELEMENTARY SCHOOL 2019 OREGON FIRE CODE AREA OF WORK MAIN BUILDING OCCUPANCY: E E j SPRINKLERED: YES 2013 NFPA 72 PERFORMANCE CLASS: SLC / NAC B FACP --- 5820XL SILENT KNIGHT EXISTING FIRE ALARM CONTROL PANEL -- EXISTING TO REMAIN a 0 2012 NFPA 70 SCOPE: 2 SSM24-6 SYSTEM SENSOR BELL RED 4-SQUARE DEEP BOX (BY INSTALLER) WALL MOUNT. MATCH MOUNTING HEIGHT OF EXISTING INTERIOR BELLS 2 (NOT SHOWN) .2 PERFORMANCE SYSTEMS INTEGRATION LLC IS PROVIDING A FIRE ALARM SYSTEM CONSISTING OF: CENTRAL STATION MONITORING •• FIRE ALARM BELL ADD IN ROOMS 31 8 32. o_ •• TIE TO EXISTING POWER SUPPLY TRANSMISSION TYPE: PHONE LINE o COMMUNICATION TYPE: OPERATIONS MATRIX MONITORING COMPANY: TBD BY OWNER w ACCOUNT NUMBER: PHONE NUMBER: N OUTPUTS < i FIRE ALARM SUBMITTAL REQUIREMENTS e � InOFFICE COPY � 1. The work site address and work activity location _ CITY OF TI GMM,. a 2. Work site owner or tenant contact name, address, and telephone number REVIEWED FOR CODE COiN1I LIANCE 5 0 3. Contractor or installer information, including state electrical license numbera 4. Description of work Approvedl:> ] LTJ 5. Three sets of scaled plans, not smaller than 11 x 17 inches. Your plans must include: OTC: [ ] � ■ � � m 5.1. Floor plan indicating the use of all rooms �� I— �� W CD g 5.2. Riser Diagram SHEET INDEX Pcrmit#: Fp•—t— -- � L ' � _ C> 5.3. Location of all alarm-initiating devices w Address: 7 I<a — F- o 5.4. Location of all alarm notification devices, including candela ratings for visible devices Q O Suite #: Z a e cc 7C) 5.5. Location of alarm control, transponders, and notification power supplies a- Q � Date: N 05.6. Annunciation FA-01 By: COVER SHEET 0 w a 5.7. Power connection � Z W J 5.8. Battery calculations J Q e RISER DIAGRAM If FA-02 z = Lu a F— > 5.9. Voltage drop calculations O z Q -0 Q z PLEASE PROVIDE z r > n 5.10. Wiring types and sizes INSTALLATION FA-03 O Q 5 LL w o COMPLETED NFPA 72 a E c 5.11. Manufacturer's data sheets with model numbers and information for equipment, devices, and U Q ac a Lu RECORD OF C a >_ N materials WIRING 1 FA-04 J Q G 0 LL COMPLETION AT `o a 5.12. Ceiling height and construction details Q Q Lu w , Y 5.13. Interface of fire safetycontrol functions a x FINAL INSPECTION A Q w O conuncAREA OF WORK FIRE ALARM DEVICE LAYOUT FA-05 Z Q w a 0 COP) 1Z WIRE SCHEDULE a Q z a Q o 0 J J Z J Q w CL a W W J 0 = � J N m J Q n 0 0 • w Q Z r LU :�i 12 AWG PAIR N O Z Lu EC 14 AWG PAIR • Q Q L N J N DRAWN BY 16 AWG PAIR • �Z �Z 1 Co w 0 vwi JM 18 AWG PAIR FPLR OR FPLP AS REQUIRED . . . . . O O Q Q N N U CHECKED BY SHIELDED FACP AC POWER LOSS • 1 • • TWISTED FACP BATTERY POWER LOSS • • • RATED FOR UNDERGROUND AND WET CONDITIONS AS REQUIRED VICINITY MAP DIALER AC POWER LOSS • • • REV. TITLE DATE SIGNAL LINE CIRCUIT SLC CABLE USE DIALER SUPPLY BATTERY POWER LOSS • • • D IST SUBMITTAL 12/23/2020 CONVENTIONAL INITIATING DEVICE CIRCUIT IDC "" NAC PW R SUPPLY AC POWER LOSS • • • ZONE INPUT _ = NAC PW R SUPPLY BATTERY POWER LOSS • • • .- SRI NaeNl D••ota 4i Sunflower Apartments' , ����>����, RELAY OUTPUT ; a ; cn •`D` NOTIFICATION APPLIANCE CIRCUIT NAC • 7 t ' $� j5 Y" W x .M < Er 1 r Ci •� M FIRE ALARM SYSTEM OPEN CIRCUIT • • • REMOTE ANNUNCIATOR 24VDC POWER • to t . a • � � '" ,. T > ai�_.Kr, z FIRE ALARM SYSTEM GROUND FAULT • • • REMOTE ANNUNCIATOR RS485 DATA W Wv cpr E • u + AUDIO RISER FIRE ALARM SYSTEM TROUBLE • • • SPEAKER CIRCUIT `yt ` DOOR HOLDER CIRCUIT • MANUAL PULL STATION • • • • AUXILIARY 24VDC POWER Fn _,,-.,, ; SMOKE DETECTOR • • • • • • - DUCTSMOKEDETECTOR • • • • • ERwe� REVISIONS NOTE: RS232-18AWG PAIR/TWISTED,SHIELDED s, A AShBeaF OSP a OF oa c� Greenfield Village HealthlnsuranceGroup SPRINKLER FLOW SWITCH • • • • E* : ?, 0 NON-POWER LIMITED aRCUrrS CAN NEVER SHARE PATHWAYS WITH POWER LIMBED CIRCUITS A artmenis s ' C3 / ti le p w,.=..,sr SPRINKLER TAMPER SWITCH • • • / i PLOT DATE 12/23/2020 12325 SW Katherine St '9 I JOHN t MARCHETTE LEA NO.W2 Tigard,OR 97223 `'_; stiy aII�)Ul sT �� �NK ER NLAO.RM 3 ack0ty,Park MpdebO�YlR �� BYSTENB, PROJECT NUMBER ��aET LEVE' \V exP. �IlzDzz i 109561 i N PERMIT NUMBER ASBUILT NOTE TO INSTALLING CONTRACTOR TBD W E INSTALLING ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SINGLE ACCURATE AND LEGIBLE REDLINED DRAWING SET. DRAWINGS SHALL S BE REDLINED AS NECESSARY TO SHOW THE FOLLOWING: • DEVICE AND PANEL LOCATIONS,ADDITIONS, DELETIONS AND ADDRESSES OR BAR CODES THE INFORMATION ON THIS DRAWING • CIRCUIT NUMBERS IS THE ORIGINAL, UNPUBLISHED WORK OF PERFORMANCE SYSTEMS • WIRE AND CONDUIT ROUTING INTEGRATION LLC • WIRE FILL USING WIRE CODE FROM LEGEND ON SHOP DISCLOSURE, REPRODUCTION, OR USE DRAWINGS WITHOUTTHE PRIOR WRITTEN CONSENT OF PERFORMANCE SYSTEMS • EOL RESISTOR LOCATIONS AND VALUES INTEGRATION LLC IS PROHIBITED. PERFORMANCE SYSTEMS INTEGRATION WILL INCORPORATE ALL REDLINED SHEET TITLE CHANGES INTO THE RECORD AUTOCAD SET OF DRAWINGS FOLLOWING THE RECEIPT OF THE DRAWING SET. COVER SHEET - FIRE ALARM N/A Z v (V X SHEET c° Lu FA-01 0 U Q BELL PWR IN/RETURN TIE TO EXISTING POWER O SUPPLY OR BELL CIRCUIT ABOVE MECHANICAL 3 ROOM e W U c4 CALCULATIONS - FIRE ALARM TBD U y U M O u U N VN � v L � o � ti d /I\ y W w o W ti u w N G v Wo g � ci o Q .9 cc v N acm O � ui 9 00 - © cC/)c Wqq' L N ry ULMEu s < 0Eu 0, PLAN SYMBOLS ; a Q � No ° AW L LL_ I N SYMBOL DESCRIPTION E FACP EXISTING FIRE ALARM CONTROL PANEL EC DRAWN BY BELL JM CHECKED BY REV. TITLE DATE 0 IST SUBMITTAL 12/23/2020 WIRE SCHEDULE 12 AWG PAIR 14 AWG PAIR 16 AWG PAIR 1S AWG PAIR FPLR OR FPLP(AS REQUIRED - - SHIELDED TWISTED RATED FOR UNDERGROUND AND WET CONDITIONS(AS REQUIRED SIGNAL LINE CIRCUR(SLC) REVISIONS CONVENTIONAL INITIATING DEVICE CIRCUIT(IDC) _ ZONE INPUT _ RELAYOUTPUT • PLOT DATE NOTIFICATION APPLIANCE CIRCUIT(NAC) _ 12/23/2020 ROOM 31 REMOTE ANNUNCIATOR 24VDC POWER REMOTE ANNUNCIATOR RS485 DATA AUDIO RISER 2e SPEAKER CIRCUIT PROJECT NUMBER DOOR HOLDER CIRCUIT AUXILIARY 24VDC POWER • 109561 NOTE:R5232-18AWG PAIR/TWISTED,SHIELDED 2B ROOM 32 NON-POWER LIMITED CIRCUITS CAN NEVER SHARE PATHWAYS WITH POWER LIMITED CIRCUITS BELL PWR IN/REFURNO EXAMPLE - EXAMPLE TIE TO EXISTING POWER RED+/BLK- RED+/BLK- PERMIT NUMBER SUPPLY OR BELL CIRCUIT "2A"CABLE ON PLAN ABOVE MECHANICAL 3 ROOM "A"CABLE ON PLAN RED+/BILK- TBD A =(2 INDIVIDUAL)18 AWG CONDUCTORS 2A= (4 INDIVIDUAL) 18 AWG CONDUCTORS RISER DIAGRAM - FIRE ALARM THE INFORMATION ON 11115 DRAWING IS THE ORIGINAL, UNPUBLISHED WORK PLAN NOTES: IN PERFORMANCE SYSTEMS INTEGRATION LLC. DISCLOSURE, REPRODUCTION, OR USE WITHOUT THE PRIOR WRITTEN CONSENT OF PERFORMANCE SYSTEMS O1 FIELD ID EXISTING POWER SUPPLY AND UPDATE BATTERY CALCULATIONS ON ASBUILTS. INTEGRATION LLC IS PROHIBITED O MATCH MOUNTING HEIGHT TO EXISTING BELLS (NOT SHOWN) SHEET TITLE RISER DIAGRAM / CALCULATIONS N/A z v (V X SHEET c° Lu FA-02 N 0 u Q Heat detector spacing —sloped ceiling Heat detector spacing — peaked ceiling `Heatdetedur _ _. • _.,�� �}=Heat dasactor I } Anywhere in this area —j; 3tft�tM) 1 I I { I a 1 1 I I I 1 w 1 I 1 I I I I I 1 I 1 I I I I i Iz I I 1 I I I I I 0 N 1 I 1 I I 1/2S= S=50ft. S=504. 1/2S= 25 R (8 m) (15m) (ISM) 25 It. (8 m) a 1 1 1 I I a y V2 S= 1 S =50 IT I S= 50 ft. 1 S=50 0 1 S =50 It 13 ft. (1 m) Rooms with peaked ceilings must have the first row of detectors placed within 3 o 25 fl (Bin) (I5Yn) (15117) (15tin (151n) max. ft.I m)(measured horizontally)of the ceiling peak.Additional detectors must be spaced based upon the horizontal projection of the ceding and ceiling I o construction. Rooms with shed ceilings having a slope greater than I ft. In 8 R. (1 m in 8 m) DETECTOR ALWAYS WITHIN IS FT. I U w HEAT DETECTOR MOUNTING must have the first Fav of detectors within 3-ft (1 m)of the high end of the I — ry ceiling.Additional detectors.if required.shall be spaced based upon the OF ANY SIDEWALL, I a horizontal protection of the ceiling and ceding construction.For roots having a c"i N i slope less than 30 degrees,horizontal spacing must be adjusted according to the r� height of the peak.For roofs having a slope greater than 30 degrees,horizontal '� V spacing shall be adjusted according to the avert sloped ceiling height. y } — C: fi o W ANNINtIIAt MINIMUM MINNIUM MINIMUM 36 in. 36 in. 36 N. 36 N. CEILING CEILING CEILING w ti ' f .' ' Z v t�t . . . . .. , . . ..' . . .','.'''`'. , . , .'.'. ••' ', . . . FLOURECENLIGHT FIXTURE J ACCEPTABLE HERE ACCEPTABLE HERE ACCEPTABLE HERECD NEVER HERE AIR SUPPLY DIFFUSER NEVER HERE NEVER HERE NEVER HERE — TOP OF DETECTOR ACCEPTABLE HERE �1 Co O W 21N. a MAXIMUM C4 O C� - 0 � ,� � C M CN C4 >` 0 (D q r` (NOT TO SCALE) /I/II�/Ie AW W '� Y 0, 1— C) Q N O W C/) 0 GO a } m •� ry T SMOKE DETECTOR MOUNTING SIDEWALL � � � F— EC DRAWN BY JM CHECKED BY REV. TITLE DATE 0 1STSUBMITTAL 12/23/2020 STROBE(GC-SERIES) Strobe PleqWrements for sleeping area In sleeping areas, where the mounting height is Within 24 in. or less of the REVISIONS NOT WITHIN 6 IN OF CEILING ceiling, the required intensity is 177 cd. When the distance would be more than 24 in.. to the ceiling. light intensities of 110 ed may be provided (see 6 Figure 4)• PLOT DATE 12/23/2020 Distance from Ceiling to Center of Lens Intensity Greater than or equaf to 24 in.(610 rrun) 110 cd FIRE ALARM CONTROL PANEL or FIRE ALARM REMOTE ANNUNCIATOR STROBE(G4/G1-SERIES) Lessthan 24 In. (f7}{}Trim) 177 cd* PROJECT NUMBER (SEE MANUFACTURER'S SPECIFICATION SHEET) 109561 LY TOP OF CONTROL DISPLAY NOT TO EXCEED 60 IN A.F.F. OP OF NAC POWER SUPPLY kinlx .�4'REF.ADA ofmwb _.- - -- 7 `MANUAL PULL STATION 30 FT MAX PERMIT NUMBER 1Mt>� bow MATBD BOTTOM OF ANY CONTROL DISPLAY NOT BELOW 361N A.F.F. 80-961N REF.ADA TOP OF BOX SUGGESTED MAX.72 IN vy f e?4 MIN.3-1/2 FT.-MAX.4 FT. B,�t� r µ, C y C y,,, - 361N 'NOTE. If the to=is larger than 16 11.x.1 V ff-, the appliance shall be located THE INFORMATION ON THIS DRAW IN: It rte •. ,��.a� ,.,r IS THE ORIGINAL. UNPUBLISHED IJ; within16 It of f,W pillow fneasured horizontally. ON INTE GRATION NC SYSTEMS DISCLOSURE, REPRODUCTION, dR USE WITHOUT THE PRIOR WRITTEN CONSENT OF PERFORMANCE SYSTEMS INTEGRATION LLC IS PROHIBITED. FLOOR OPERATING HANDLE TO FLOOR TOP OF DEVICE TO FLOOR LENS TO FLOOR LENS TO FLOOR MOUNT IN ACCESSIBLE LOCATION SHEET TITLE INSTALLATION ELEVATION NOTES: INSTALLATION - ELEVATION THIS DETAIL IS NOT DRAWN TO SCALE. SOME DEVICES SHOWN MAY NOT EXIST IN PLAN. N/A SEE SPECIFIC DEVICE INSTALLATION SHEETS FOR MOUNTING HEIGHT OF BACK BOX. THE BOTTOM OR TOP OF INSTALLED Z DEVICE MAY NOT CORRESPOND TO INSTALLED BOX. CV X SHEET 110 w FA-03 N 0 _ U w Q SSM24-6 WIRING Typical SSM and SSV bell wiring diagrams: WIRING (REAR VIEW) OBSERVE POLARITY USE BOTH LEADS FOR ON SSM MODELS CONNECTION, BREAK WIRE RUN TO PROVIDE ELECTRICAL SUPERVISION. W HPI) BLACK a 0 HL L, BLACK d U a" v WIRE NUTS TO NEXT FROM (User supplied) _ BELL OR U CONTROL , J11, END-OF-LINE PANEL RESISTOR — 24VDC WIRING DIAGRAM A0154-+00 � o } rn C (D v3F O V/ 0. EQ 8 � u b d LU W O y z Q 5 /3 cc N 0 QCo U 0 � F- o p0 E: N Ems ° � C � lAn o ^ a w g �z rr Wo /1W v� N n a CL cn LL m EC DRAWN BY JM CHECKED BY REV. TITLE DATE 0 1STSUBMITTAL 12/23/2020 REVISIONS PLOT DATE 12/23/2020 PROJECT NUMBER 109561 PERMIT NUMBER TBD THE INFORMATION ON THIS DRAWING IS THE ORIGINAL, UNPUBLISHED WORK OF PERFORMANCE SYSTEMS INTEGRATION LLC. DISCLOSURE, REPRODUCTION, OR USE WITHOUT THE PRIOR WRITTEN CONSENT OF PERFORMANCE SYSTEMS INTEGRATION LLC IS PROHIBITED. SHEET TITLE WIRING 1 N/A Z v N X SHEET C° w FA-04 C0 0 U Q PLAN SYMBOLS SYMBOL DESCRIPTION L FACP I EXISTING FIRE ALARM CONTROL PANEL I ` BELL i r ! j i x WIRE SCHEDULE a 12 AWG PAIR 14 AWG PAIR - - _ • • • o �_ 16 AWG PAIR • • aa 18 AWG PAIR • • 9 0 31 — AC I!Vi Y ROOM FPLR OR FPLP(AS REQUIRED) • • • • , SHIELDED U_ w TWISTED rryryry RATED FOR UNDERGROUND AND WET CONDITIONS(AS REQUIRED) • • • • • • • U _41 zs L i SIGNAL LINE CIRCUIT(SLC) CONVENTIONAL INITIATING DEVICE CIRCUIT(IDC) _ y ZONE INPUT — c RELAY OUTPUT o'b. NOTIFICATION APPLIANCE CIRCUIT(NAC) • a Ei REMOTE ANNUNCIATOR 24VDC POWER REMOTE ANNUNCIATOR RS485 DATA °j LL !�-""-""---"""— --_---- - AUDIO RISER UJ Z SPEAKER CIRCUIT CD 9 ,l DOOR HOLDER CIRCUIT AUXILIARY 24VDC POWER F- !� \. 7> y ! NOTE:RS232 - 18AWG PAIR/TWISTED, SHIELDED 0 NON-POWER LIMITED CIRCUITS CAN NEVER SHARE PATHWAYS WITH POWER LIMITED CIRCUITS a 0 Lu 00 EXAMPLE EXAMPLE - 3 0 a - RED RED "2A,"CABLE ON PLAN a° ON PLANE L.- C4 c � RED+/BLK- � � 0 0 ` N C4 10 W A = (2INDIVIDUAL)18AWG CONDUCTORS 2A= (4INDIVIDUAL) 18 AWG CONDUCTORS 3 O � ccI,_ Q Q w 0 ----- -- Ww N Ln -0 l a } M � °a 28 PLAN NOTES: F__ -- I - -- - ..—� 11 O1 FIELD ID EXISTING POWER SUPPLY AND UPDATE BATTERY CALCULATIONS ON ASBUILTS. EC O2 MATCH MOUNTING HEIGHT TO EXISTING BELLS(NOT SHOWN) DRAWN BY JM I CHECKED BY I REV. TITLE DATE 34 ORKRt�t()VI 0 15TSUBMITTAL ]2/23/2020 Y I i i I I 32 BORMON i i _. - REVISIONS "" PLOT DATE i ------------------ _ 12/23/2020 WuKKRoOM _ _ _ ' PROJECT NUMBER v — 109561 2B — i KEYPLAN - AREA OF WORK PERMIT NUMBER I TBD _ BELL PILAR IN/RETURN --'' OY TIE TO EXISTING POWER SUPPLY OR BELL CIRCUIT L3ROOMABOVE ✓ t jVI( A _ - _ 3 I - THE IWORMAT10N ON THIS DRAWING Is THE ORIGINAL,OF PERFORMANCE SYS EMSSIIED WORK INTEGRATION LLL. i WITHOUT DISCLOSURE, REPRODUCTION, OR USE R. I BACONSENT OFEPEREN FORNANCET SYSTEMS INTEGRATION LLC IS PROHIBITED. SHEET TITLE AREA OF WORK DEVICE LAYOUT N O AREA OF WORK - FIRE ALARM DEVICE LAYOUT SHADED AREAS NOT IN SCOPE 1 /4" – l'-O" Z CV X SHEET 'O co 16' W N_ SCALE RULER N FA-05 0 U Q