Plans (34) BUP2020 -00223 OFFICE COPY 4 ;I RARM� etM DISCOVER & LIFE ENCOUNTER COUNSELING OF TIGARD , OREGON RECEIVED DESCRIPTION OF WORK OCT 15 2020 SUITE 215 IS AN EXISTING OFFICE, GROUP B OCCUPANCY.AND WILL CITY OF TIGARD CONTINUE TO BE USED AS OFFICES.SCOPE OF WORK INCLUDES NEW BUILDING DIVISION DISCOVER & LIFE ENCOUNTER COUNSELING TENANT TENANT IMPROVEMFNTWITH INTERIOR PARTfIIONS Z RELEASES o 7340 SW HUNZIKER RD, SUITE 215 c OSSC 1004 OCCUPANT LOAD TABLE Q o TIGARD, OR 97223 a $ ROOM LOADING # NAME OCCUPANCY TYPE FACTOR AREA LOAD a COVER SHEEP 200 ENTRY BUSINESS 150 51 0 0 � • • CSI COVER LHEET 201 WAITING BUSINESS 150 138 1 • • 203 HALLWAY --- --- =ITECTURALARCH2 " 81 T1.1 DEMO PLAN, FLOOR PIAN& DETAILS CONSTRUCTION CONTRACTOR • • 304 OFFICE BUSINESS 150 146 I T1.2 REFLECTED CEILING PLAN. FINISH PLAN&SCHEDULE — a 205 OFFICE BUSINESS 150 94 1 21360 NW AMBERWOOD DR CONTACT: RYAN ROBINSON 206 OFFICE BUSINESS 150 136 1 HILLSBORO, OR 97124 207 BREAK ROOM BUSINESS I50 97 1 TELEPHONE: 503.645.8531 \ 208 OFFICE BUSINESS 150 148 I FAX: 503.645.5357DFN ` DR. TOTAL FOR OCCUPANT LOAD 935 5 SW UAHURST � SW HERMOSp W Y DEFERRED SUBMITTALS < °D CIDA, INC. �� a ARCHITECT sw rREFc K MECHANICAL , SW PION ST ELECTRICAL(INCLUDING LIGHTING) 15895 SW 72ND AVE, SUITE 200 PORTLAND, HONI�KER CONTACT: JEN HAWKINS RD. r a *DESIGN-BUILD CONTRACTOR SHALL COMPLETE,AS NECESSARY,REQUIRED OR 97224 SW GRESMEW PORTIONS OF THE OREGON ENERGY COMPLIANCE FORMS �• �,� TELEPHONE: 503.226. 1285 4 SW YARNS ST "CONTRACTOR TO SUBMIT DEFERED SUBMITTAL DESIGN DRAWINGS TO 1i ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO SUBMISSION TO CITY FOR FAX: 503.226. 1670 PERMIT REVIEW. g 5 BUILDING CODE SUMMARY K lio r SW SANDBURG S7 LEGEND SW TECH 0019 ? D ' GOVERNING CODE 2019 OREGON STRUCTURAL SPECIALTY CODE 15895 SW 72ND AVE SUITE 700 JO PORTLAND. OREGON 97224 T. j OCCUPANCY TYPE: GROUP B T E L : 5 0 3 - 2 2 6 1 2 8 5 sw LANDMARK (E)WALL NOT IN SCOPE SPRINKLERED VS.NON-SPRINKLERED: NON SPRINKLERED F A X : 5 0 3 . 2 2 S . 1 6 7 0 CONSTRUCTION TYPE: V-A www . c I D A I N c . c o N 40 ONES EXIT DISCHARGENORTH 2 VICINITY MAP ® PORTABLE FIRE EXTINGUISHERS SHALL BE BE ILLUMINATED FRIT SIGN O PORTABLE FIRE EXTINGUISHERS (HALL PROVIDED IN OCCUPANCIES AND LOCATIONS AS REQUIRED _ ,..,T COMMON PATH NO SCALE OREGON FIRE CODE AND THE FIRE MARSHALL �"^' �� I ' :► _ t . /17 THE ISSUANGt Z OCCUPANCY LOAD(OSSC 1004): EASED CN C Ot!S?F'UCTL)151 GROSS FLOOR AREA(SUITE 100):983 SF/ 150= 6-55 = 7 OCCUPANT LOAD DOCU!ArNTS D,Ni) OTFa-W AREA OF WORK (SEE ALSO OCCUPANT LOAD TABLE ON THIS SHEET) D,AI A SHALL Ijr-T PHEb i\f T SUITE 215 THE CODE OFF;'OAL FE1511I W MEANS OF EGRESS ILLUMINATION (HALL 1006): ILLUMINNL L( 161. : }REQUIRING THE COROF ERRORS. OSSC 105.:1RY l ECIICA rr ww In I ATIOEVEHALL 001) r- �I MINIMUM I FOOT-CANDLE AT THE WALKING SURFACE LEVEL �J N i', (A�Ei 205 ILLUMINATION EMERGENCY POWER(OSSC 1006.3): ` EMERGENCY POWER SHALL BE PROVIDED FOR A DURATION OF 90-MINUTES MINIMUM ' W AREAS REQUIRED TOBEILLUMINATED BY EMERGENCY POWER E � -CORRIDORS AND EXIT PASSAGEWAYS Q 7a - INTERIOR EXIT DISCHARGE ELEMENTS V i y -EXTERIOR LANDINGS E1!38FA5 RM 03 w/ N 2-07 J _ EMERGENCY POWER FOR ILLUMINA I ION (OSSC 1006.3): 6� UJ y / INITIAL ILLUMINATION: OFFICE COPY 0TOM Q O I '02 4 1 FOOT-CANDLE AVERAGE W/0.1 FOOT-CANDLE MINIMUM AT ANY POINT AT FLOOR LEVEL END OF EMERGENCY LIGHTING PERIOD: • I 20 0.6 FOOT-CANDLE AVERAGE W/0.06 FOOT-CANDLE MINIMUM AT ANY POINT AT FLOOR LEVEL z Q L LL I (F1 NUMBER OF EXITS AND EXIT CONFIGURATION (TABLE 1006) Lli NON-SPRINKLERED PATH OF EXIT VEL (TABLE BUILDING,BUILDING B OCCUPANCY REVIER DG CITY OF TIGARD, p V W O WED POCilCOMPLIANCE ii 7 b MAX TRAVEL DISTANCE ALLOWED: 100' (COMMON PATH) Q MAX TRAVEL DISTANCE: 5T-9" Approved."" z Y I OTC: t ] z W N Q TOTAL OCCUPANTS:7 OCCUPANTS Permit #: Q Z _0 -- - - spommom ■ MmMMMw ■ MMMMM ■ M moummmm = = = = = A ■ % I EXIT REQUIRED �V�7�Oc�LO- OCD a33 Z (� ® ® . ■ N i : ® t EXIT PROVIDED Address: 7 3 y 0 < / LI n C� ■ __ ■ ' � ■ ■ / ILLUMINATION (HALL 1008): Suite #: � ■ ■ ■ I/ EXIT SIGNS SHALL BE IN?ERNALLY OR EXTERNALLY ILLUMINATED By: Date: L/ - 3_ '� i EXIT ACCESS TRAVEL DISTANCE (OSSC 1017): N ■ (TABLE 1017.2) ■ L ■ .m NON-SPRINKLERED BUILDING, B OCCUPANCY:200'-0'ALLOWED O ■ I MAX DISTANCE= 168'-5' W 13 ID Ilt L- --� W ■ — EGRESS WIDTH REQUIRED (TABLE 1005.1) > ■ ■ SUITE 215 PASSAGEWAY EGRESS WIDTH REQUIRED (10 x .2) = 2* O ■ SUITE 215 PASSAGEWAY EGRESS WIDTH PROVIDED = 36" ■ V ■ ACCESSIBILITY(OSSC CHAPTER I I AND ANSI CHAPTER 5): tA ■ SEE FLOOR PLANS FOR REQUIRED CLEARANCES AT DOORS,TOILET ROOMS (EXISTING)AND FIXTURES. Q ■ ALL SIGNAGE GRAPHICS,LOCATION AND MOUNTING TO COMPLY WITH OSSC CHAPTER I I o ■ ■ ZONING CODE INFORMATION COVER SHEET G 0 TAX MAP& LOT: 2S 101 DB00100 E a NORTH NORTH ZONING:C-P PROFESSIONAL COMMERCIAL csi 1 ESS PLAN -- SECOND FLOOR 2 EGRESS PLAN -- SECOND FLOOR 20Y193.01 -770" -0' �'� 3132'= I'- 0'070 Ck)A PPi l PKHS RIS=RJFD 9 ____ DOOR SCHEDULE O O DEMO FLOOR PLAN LEGEND DOOR # DOOR TYPE HARDWARE OPENING WIDTH DOOR DOOR DOOR FRAME FRAME FINISH NOTES DOOR # (E) EXTERIOR WALL GROUP x HEIGHT THICKNESS MATERIAL FINISH MATERIAL S. -- - - (E) PARTITION TO REMAIN (E)200-A --- --- --- --- OR (F_)OF�CE (QOM - - - - (E) PARTITION TO DEMO 201-A A 2 3'-0"x7'-0' 1 3/4" SC STAINED HMKD PREFINISHED --- 201-A ' 206 205 - - - - 201-B A 1 3'-0"xT-0" 1 3/4" SC STAINED HMKD PREFINISHED --- 201-B O DEMO FLOOR PLAN GENERAL NOTES (E)OFFICE 202-A B 1 3'-0"x7'-0" 1 3/4" SC STAINED HMKD PREFINISHED --- 202-A 2oa 1. ALL CONDITIONS SHOWN OR IMPLIED ON THE DRAWINGS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. NOTIFY (E)204-A A 1 3'-0"x7'-0" 1 3/4" SC STAINED HMKD PREFINISHED --- (E)204-A ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO THE START - — -- OF WORK. (E)205-A A 1 3'-0"x7'-0" 1 3/4" SC STAINED HMKD PREFINISHED --- (E)205-A ° 2. VCT FLOORING AT BREAK ROOM TO REMAIN. - - (E)206-A A 2 3'-0"x7'-0" 1 3/4" SC STAINED HMKD PREFINISHED --- (E)206-A (E)BREAK ROOM - 207 (E)208-A A 1 3'-O"x7'-0" 1 3/4' SC/GL STAINED HMKD PREFINISHED --- (E)208-A ABBREVIATIONS: Z Ti DEMO FLOOR PLAN KEYNOTES N - - -- - �,"W� SCHEDME SC EXISTING 3 - -- - - _ - SC SOLID CORE WOOD � z _ 1 EXISTING CASEWORK, PLUMBING FIXTURES AND DISHWASHER TO L / ¶ REMAIN. HMKD HOLLOW METAL KNOCK DOWN GL TEMPERED GLASS Q o /7/ OFFICE TYPE 1 PASSAGE TYPE 2 F - -� GENERAL NOTES: al I r O 1 EA OFFICE LOCKSET 1 1/2 PAIR BUTTS 1. ALL NEW DOORS TO MATCH EXISTING, SPECIES, STAIN, o 0 (E)STORAGE FINISH, HEIGHT & HARDWARE. o II zol 2. THE OPENING FORCE SHALL NOT EXCEED 5 LBS FOR y 1 1/2 PAIR BUTTS 1 EA PASSAGE LATCH INTERIOR DOORS, 8.5 LBS FOR EXTERIOR DOORS, AND n o (E)OFFICE OPEN I THE MINIMUM FORCE REQUIRED TO CLOSE AND LATCH zoo L THE DOOR FOR FIRE DOORS. OSSC 1109.9.9 - L - 1 SET SILENCERS 1 SET SILENCERS 3. ALL HARDWARE SHALL COMPLY WITH THE REQUIREMENTS OF THE ADA. 4. DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT 1 EA WALL STOP 1 EA WALL STOP THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. (E OFFICE 5. CONTRACTOR TO VERIFY HARDWARE FUNCTION INDICATORS zoa 1 EA STRIKE FOR ALL DOORS WITH OWNER PRIOR TO ORDER/INSTALL. 1 NIOR711 t'Sa) PARTIAL FIRST FLOOR DEMO PLAN 5 5 T1.1 1/4" = 1'-0" T1.1 T1.1 W" ,.W„ 5 1 . 5 T1. T1. FLOOR PLAN LEGEND 6 P. 1:895 SW 22ND AVE SUITE 200 '30 RTLAND. OREGON 91224 ' F L 5 0 3 2 2 6 1 2 8 5 CORRIDOR ROOM NAME & NUMBER ? = r A x 5 0 3 . 2 2 6 . 1 6 1 0 1U3 v w W W . C 1 D A 1 N C C 0 M O O (E) EXTERIOR WALL T (N) INTERIOR WALL D _ (E) INTERIOR WALL TO REMAIN FINISH FLOOR r n V (E) EXISTING A FLUSH ( n \FLUSH W/ GLASS Z m (E OFFICE m (E)OFFICE .. T = TEMPERED GLASS los 205 201-A DOOR NUMBER (SEE 12/Tt.t) FOF FACE OF FINISH La � I I m (E)OFFICE WALL TYPE 3 DOOR/RECITE TYPES Z B N N B FIRE EXTINGUISHER- TO REMAIN Ldu 10'-4" FLOOR PLAN KEYNOTES w N (E)BREAK ROOM HALLWAY d W I 207 2oa A O REFRIGERATOR - TENANT PROVIDED/ CONTRACTOR INSTALLED. 0 z -_I-- i1 PROVIDE ELECTRICAL I_ Q O 204-A O ADD (2) LAYERS OF SOUND ATTENUATION BATT. ABOVE (E) WALLS Q z Z O WHERE NOTED SECURE TO UNDERSIDE OF DECK W o -- -- - WITH 2 0.138" DIA. POWDER w � 4 -0 ( ) �- 201-8 DRIVEN FASTENERS OR (2) 1" TYPE O A CLEAR =' SOUND ATTENUATION BATT ABOVE O O W FLOOR PLAN GENERAL NOTES o Z TOP OF WALL Y WAITING 1. ALL CONDITIONS SHOWN OR IMPLIED ON THE DRAWINGS SHALL BE A 201 VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. NOTIFY SUSPENDED CEILING Q W Z ARCHITECT ENGINEER OF ANY DISCREPANCIES PRIOR TO THE START z W B 208 A O / PROVIDE METAL STUD BRACE AT w HALLWAY OF WORK. I m I- Li 6'-0" O.C. TO STRUCTURE ABOVE � _ 202 AND TO TOP PLATE OF PARTITION WALL PER PLAN (DOUBLE STUDS $ 2. ALL DIMENSIONS ARE TO CENTER OF WALL UNLESS NOTED OTHERWISE. J A WITH (2) 1" TYPE 'S' SCREWS - AT ALL JAMBS) — 3. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AND INSTALLED AS TRIM PANEL AS REQUIRED. Y REQUIRED BY APPLICABLE STANDARDS w 4. PROVIDE BLINDS PER BUILDING STANDARD, IF NECESSARY. HEAD CONDITION / W o wFULL THICK SOUND ATTENUATION Wt m (E)OFFICE m P 5. PATCH AND REPAIR (E) FINISHES TO MATCH WHERE DAMAGE HAS m BATT > M o OCCURRED DUE TO CONSTRUCTION. PAINT ALL NEW WALLS (U.N.O.) - ? METAL STUD PARTITION PER PLAN o TO MATCH (E). N HOLLOW METAL JAMB O u CLEAR A 1 6. ALL ELECTRICAL OUTLETS TO CONFORM W/ 2019 OREGON SPECIALTY ELECTRICAL CODE. BASE _ N_ ENTRYw BOTTOM TRACK TO FLOOR WITH I� DOOR PER SCHEDULE Q 200 7. . EXISTING CASEWORK, PLUMBING FIXTURES AND DISHWASHER TO REMAIN a 2'-2�" CCORNERS AND E DS (MAX) AND AT N o 201-A yyy FOF DEMO PLAN, FLOOR - - -_-- _ WALL TYPES PLAN & DETAILS - 3-1/2" METAL �l STUDS ® 1'-4" O.C. W/ ONE LAYER 5/8" ��.� x NORTH GYPSUM BOARD EACH SIDE TO THE UNDERSIDE 2 PARTIAL FIRST FLOOR PLAN OFF THE CEILING. PROVIDE SOUND 4 A WALL TYPE 5 TYPICAL INTERIOR DOOR DETAIL ATTENUATION INSULATION.-- SEE DETAIL 20Y193.01 6 Tt1 1/4" = 1'-0" 4/T1.1 Tt1 3/4" = 1'-0" 092900-03 T11 3" = 1'-0" ©20)C CDA,flUCDA All RKA i 15 RF5FRVPG RCP LEGEND 491D p COR'R01DOR ROOM NAME & NUMBER ' I 2X2 (E) LAY IN ACOUSTICAL CEILING GRID- TO (E 0°F�FICE (E zos E _--_ REMAIN r' �� of 2X4 (E) LAYIN FLUORESCENT LIGHT FIXTURE TO (ME REMAIN AS SHOWN I 2X4 (E) LAYIN FLUORESCENT LIGHT FIXTURE CONNECTED TO EMERGENCY POWER SOURCE (E)BREAK ROOM HALLWAY II \\ II 2X4 (N) LAYIN FLUORESCENT LIGHT FIXTURE RELOCATED AS SHOWN v L LJ Z N I 2X4 (N) LAYIN FLUORESCENT LIGHT FIXTURE Z -77 � I CONNECTED TO EMERGENCY POWER SOURCE � _ z o 2X4 (E) LAYIN FLUORESCENT LIGHT FIXTURE r w I II DEMO FOR RELOCATION AS SHOWN d--------------- a O I HALLWAY =I L (E) ILLUMINATED EXIT SIGN o" v P �j r RCP GENERAL NOTES 1. LIGHTING INDICATED ON THIS PLAN IS FOR DESIGN INTENT ONLY AND WAITING IS FOR DESIGNING A FINISHED INTERIOR LIGHTING LAYOUT THAT 207 COMPLIES WITH RECOMMENDED LIGHTING LEVELS PUBLISHED IN THE ( Zoe CE ENTRY I 11 CURRENT IES LIGHTING HANDBOOK FOR THE FUNCTION OF SPACES 200 INDICATED. CONTRACTOR SHALL SUBMIT A PHOTOMETRIC STUDY WITH COMPLETED ENERGY CODE FORMS ASSOCIATED PRODUCT CUT SHEETS FOR ARCHITECT APPROVAL. SEE SITE PLAN GENERAL NOTES FOR --/ REQUIREMENTS REGARDING SITE LIGHTING (VERIFY). 2. MEANS OF EGRESS ILLUMINATION: CONTRACTOR SHALL INSTALL EGRESS LIGHTING SUCH THAT A MINIMUM ILLUMINATION LEVEL OF 1 FOOTCANDLE IS MAINTAINED AT THE WALKING SURFACE ALONG THE PATH OF EGRESS, LIGHTING SHALL BE CONNECTED TO AN EMERGENCY BACKUP POWER SYSTEM (TYPE INDICATED ON DRAWINGS) AND SHALL TE IMUM OF DE �I 3. BBOEDING'S TO CEILING GRID,9UO.NS INTERRUPTED.IN THE EVENT THE BUILDING'S MAIN POWER SOURCE IS INTERRUPTED. - - - 4. SALVAGE AND REUSE EXISTING CEILING/LIGHTING FIXTURES WHERE , POSSIBLE. ANY NEW FIXTURES REQUIRED TO MATCH EXISTING. 5. PATCH AND REPAIR (E) GRID & TILE WHERE DEMO HAS OCCURRED. 6. VERIFY (E) EXIT SIGNS AND PROVIDE SIGNAGE AS SHOWN. NORTH 1 PARTIAL FIRST FLOOR RCP PLAN T1.2 1/4" = 1'-0" 15895 SW 72ND AVE SUITE 200 PORTLAND. OREGON 97224 E L : 5 0 3 2 2 6 1 2 8 5 ? X 5 0 3 2 2 6 1 6 7 0 W C I D A I N C . C O M 0 FINISH FLOOR PLAN LEGEND CORRIDOR ROOM FNMSC� ROOM NAME & NUMBER 'i " ROOM # ROOM NAME FLOOR BASE N WALL E WALL S WALL W WALL CEILING HEIGHT NOTES _z � II200 ENTRY CPT-1 B-1 PT-2 PT-1 PT-1 PT-2 CL-1 (E) J I E(E OFFICE OOFs ICE uj 205 CPT-1 _Z 201 WAITING CPT-1 B-1 PT-2 PT-1 PT-1 PT-1 CL-1 (E) U) y PT-3 202 HALLWAY CPT-1 B-1 PT-1 PT-1 PT-1 PT-2 CL-1 (E) Z N 203 HALLWAY CPT-1 B-1 PT-1 PT-1 PT-2 PT-1 CL-1 (E) (EOFFICE (E) VCT-1 204 OFFICE CPT-1 B-1 PT-2 PT-1 PT-3 PT-1 CL-1 (E) O Ld z°a 205 OFFICE CPT-1 B-1 PT-1 PT-3 PT-1 PT-1 CL-1 (E) V 206 OFFICE CPT-1 B-1 PT-1 PT-1 PT-1 PT-3 CL-1 (E) 1w o FINISH FLOOR PLAN LEGEND 207 BREAK ROOM VCT-1 B-1 PT-1 PT-2 PT-2 PT-1 CL-1 (E) d0 LY Q z 208 OFFICE CPT-1 B-1 PT-1 PT-1 PT-3 PT-1 CL-1 HALLWAY ( Ot CONTRACTOR TO PROVIDE METAL SCHLUTER, OR EQUAL, (E) Z H Q O I I— I T (E)BREAK ROOM z02 203 TRANSITION STRIP BETWEEN FLOORING MATERIALSLIST OF �SHES z w D W m - - - E � — — _ — FLOORS BASES WALLS CEWNGS CASEWORK0 O Q CPT-1 B-1 PT-1 CL-1 EXISTING TO REMAIN L FINISH FLOOR PLAN NOTES Z Y o ' CARPET TILE, PATCRAFT, 4" RUBBER BASE, PAINTED GYPSUM BOARD EXISTING 2x4 Q — 1. VERIFY ALL FINISH SELECTIONS WITH TENANT AND OWNER PRIOR TO COLLECTION: URBAN ROPPE, 174 SMOKE FIELD PAINT, BENJAMIN MOORE, ACOUSTICAL CEILING TILE Z W RELIEF, 10515 EASTERN HC-170, STONINGTON GRAY Q Z ORDER/INSTALL. , 0550 TUNNEL, z LN FACADE0 — 2. HATCHES SHOWN FOR REPRESENTATIONAL PURPOSES ONLY. CONTACT FAC24" F- J - O ARCHITECT/DESIGNERX , 0 INSTALL LL FOR INSTALLATION DIRECTIONS AND METHODS. _ HALLWAY 3. PATCH AND REPAIR ANY DAMAGES WHERE DEMOLITION HAS OCCURRED. BRICK ASHLAR 202 4. CONTRACTOR TO VERIFY W/TENANT EXACT REQUIREMENTS AND ' LOCATIONS OF ELECTRICAL/DATA/PHONE OUTLETS. TENANT VCT-1 PT-2 EXISTING TO REMAIN V) RESPONSIBLE FOR CONTRACT FOR LOW VOLTAGE DESIGN AND EXISTING VINYL PAINTED GYPSUM BOARD INSTALLATION. COMPOSITION TILE, TO ACCENT, SHERWIN WILLIAMS, ' REMAIN SW6340, BAKED CLAY Q WAITING Lu It 201 (E)OFFICE M 2F ENT O PT-3 V PAINTED GYPSUM BOARD ACCENT, SHERWIN WILLIAMS, SW7673, PEWTER CAST Q R R I r RCP, FINISH PLAN & 's SCHEDULE 4 T1.2 NORTH 20Y 193.01 2 PARTIAL FIRST FINISH FLOOR PLAN o T1.2 1/4" = 1'-0"