Plans (24) BUP2020 -00198 BUILDING LOCATION RECEIVED !#3082 TENANT IMPROVEMENT OFFICE COPY MARTIN W.HAN5,;S�t, AUG 2 4 2020TO PORTLAND EXIT AN RD -_ r CITY OF TIGARD LI1 CLA KAM S,ORE for BUILDING DIVISION �a ,2 _ 13 15 -- { PAcTR u sT (� of o� 16 PROJECT #20380 14 � Tenant. ,7 18 GAA�� MERCURY DEVELOPMENT z p� o �� a A a a os���� PROJECT NARRATIVE T m s �'� MERCURY DEVELOPMENT CURRENTLY OCCUPIES 4,132 SF OF SPACE. . HIS PROJECT U s < e 4 2 , �� CONSISTS OF SPLITTING THE EXISTING SPACE INTO TWO SEPARATE TENANTS WITH 0 3 �� MERCURY DEVELOPMENT RETAINING 3,148 SF WITH THE REMAINING SPACE TO BE o �� A LEASED TO OTHERS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO C o 10 W e • SELECTED DEMO OF EXISTING NON STRUCTURAL WALLS n NON STRUCTURAL DRYWALL/METAL STUDS WALLS W72 VENUE • SUSPENDED CEILINGS (>3 = aN • DOORS/FRAMES AND PAINTING SITE MAP a N A-1 NorroscALE — z� • ELECTRICAL DISTRIBUTION ' o cy • LIGHTING a o o U.) ALL WORK TO MEET ADA REQUIREMENTS. C CO o o Z U) J WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT o � M M m L0 L0 _zaoro• - _– --.__.. - -_.–__. ._ _- _–_____— - __ In 30ro' 30ro' 30`0' 150' 30`0' 15`0' 30`0• 3010' 30ro' \J FIRE PROTECTION SPRINKLERING NHEATING, VENTILATION & AIR CONDITIONING WORK B - ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE a m_ c v c U ----- BUILDING INFORMATION 1 OWNER: PACIFIC REALTY ASSOCIATES, L.P. E - -- - - - - - - - L = - -- -- - -- - -- 15350 SW SEQUOIA PKWY #300-71 - - - - - b - PORTLAND, OR 97224 - - - 1 (503) 624-6300 (PHONE) R 1 �}-� 1 1 (503) 624-7755 (FAX) 1 I `� 1 ' BLDG. #: pcc241 (Bldg. 17) LA CONST. TYPE.: li-B �+ a I 1 1 THIS BUILDING HOUSES SEVERAL SEPERATE TENANTS INCLUDING THIS TENANT. THE EXISTING ud 1 1 BUILDING IS A THREE STORY BUILDING OF 62,000 SF AND IS FULLY SPRINKLERED. THERE IS - - - - 1 1 FRONTAGE ON ALL FOUR SIDES OF AT LEAST 60 FEET. F a K - - - - - I l,� . � ACTUAL BUILDING AREA TOTALS 14 LZ AREA OF WORK , B OCCUPANCY = 61 ,500 SF EL 7 OVERALL BUILDING PLAN 2 - S-2 OCCUPANCY = 500 SF 0_ A 1 1/16" = r-G° � TOTAL 62,000 SF W MIXED OCCUPANCY - NON-SEPARATED USES. (OSSC 508.3.2) > w W z � ALLOWABLE AREA C) L.0 wav PER TABLE 503, TYPE III-A: Q Orn B OCCUPANCY IS 28,500 + 4 STORIES @ 28,500 + 1 STORY FOR SPRINKLERING = 171 ,000 SF OFFICE COPY V o 0O CITY OF TIGARD?, �/ U �: Q 62,000 SF (3 STORIES) < 171 ,000 -NON-SEPARATED USES ALLOWED. REVIEWED FOR CODE COMPLIANCE w o OTC:ved:� I U CO D_ TENANT INFORMATION _ 0 ' Pcrmit #: DATE: 7/28/20 TENANT: MERCURY DEVELOPMENT Address: -S PERMIT Suite #: 1 y o _ OCCUPANCY AREAS & LOADS: By. Date: (� ' - a� REVISION B 3,148 SF 32 OCC 1. NUMBER OF EXITS REQUIRED 2. B 1 EXITS 3. 4. CODE SUMMARY 5. 6. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH STATE AND LOCAL CODE 7. REQUIREMENTS THAT APPLY, INCLUDING BUT NOT LIMITED TO: • 2019 OREGON STRUCTURAL SPECIALTY CODE (OSSC) $' • 2019 OREGON MECHANICAL SPECIALTY CODE (OMSC) 2017 OREGON PLUMBING SPECIALTY CODE OPSC VALIDITY DRAWN BY: • ( ) OF PE:P,"IT R.M.T. • 2017 OREGON ELECTRICAL SPECIALTY CODE (OESC) THE ISSUANCE OFAPEPMIT BASED ON CONSTRUCTION • 2019 OREGON FIRE CODE (OFC) DOCUMENTS AND OTHER • ASCE-7-1 O DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM • ICC/ANSI A117.1-2017 REQUIRING THE CORRECTION 0 2019 OREGON ENERGY EFFICIENCY SPECIALTY CODE OF ERRORS. OSSC 105.4 0100 00 GENERAL DATA 7. TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. a ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED INDUCT AT OR NEAR CLOSEST GENERAL REQUIREMENTS 8. USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH WYE BRANCH. 1. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND SYSTEM. d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT MS,OREGON NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. WALL CONSTRUCTION EXECUTION COMPLETION.ll.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE 2. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPINGCONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW HONEYWELL COMMERCIAL GRADE VISI IGNATNPRO 8000 TOUCH SCREEN MODEL TB8 ODES N3 WHERE POSSIBLE. CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD APPROVED SUBSTITUTE: CKOUT FUN SIGNATURE COMMERCIAL THERMOSTATMODEL NO. IGHT 800 -7 DAY THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. MATERIALS LIGHTER THAN 18 GA. PROGRAMMABLE WITH LOCKOUT FUNCTION-AU70 CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM 3. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS THERMOSTATS AND BALANCE SYSTEM. EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. 12.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. O DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION 11.EXHAUST FANS: ��\? LEFT IN THE TENANT SPACE AS NOTED ON PLANS),CLEANING AND ALL PREPARATION OF SUBSTRATE STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT S IIC6110 3 WUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT Orj O SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE ' (, CODE'REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR. J1.• 4. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE -I`1 COON GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.8 OR LESS,100 CFM WITH A STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP •.SONE RATING OF.9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. INTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS.PROVIDE LONG LEG b. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING PROJECT #20380 5. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE. MOUNTED EXHAUST FANS,WIRED PER DIVISION 16 AND SWITCHED WITH THE LIGHTS. 6. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING 4. REMOVE EXISTING FLOORING AT NEW WALLS UNLESS SPECIFICALLY INDICATED BY ARCHITECT. - c. MULTIPLE FIXTURE RESTROOMS,COMBINATION RESTROOM&SHOWER,AND LOCKER ROOMS TO HAVE CARPETS. 5. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR ROOFTOP MOUNTED EXHAUST FAN,FACTORY CURB AND BACKDRAFT DAMPER,WIRED PER DIVISION 16, 7. CONTRACTOR MAY SUBMIT ALTERNATE ROOFING CONTRACTOR TO BE REVIEWED AND APPROVED BY THE PROJECT. CONTROLS AS REQUIRED BY DESIGN.COOK ACE-D SERIES OR EQUAL. PACTRUST PRIOR TO BID. 6. AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING, INSTALL THE GYPSUM BOARD(OR AUQATOUGH) d. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS- }i 8. VERIFY WITH BUILDING OWNER ANY ROOF WARRANTY REQUIREMENTS. WITH 1/4"GAP BETWEEN THE BOARD AND THE FLOOR TO PREVENT WICKING. INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,SHALL HAVE A U 7. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. ROOFTOP MOUNTED FAN. ^+ 9. KEEP THE ROOF FREE OF DEBRIS(LE.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. 14.HVAC TESTING. W 10.ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH B. FINISH QUALITY: ♦0 A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 AREA PROCESS TRADE NOMENCLATURE a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. OFFICEIOTHER AREAS TAPE/2 FINISH COATS`/ SMOOTH FINISH TAPED(LEVEL 4) APPROVED PLANS AND SPECIFICATIONS. 11.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS USG*FIRST COAT 'SAND AFTER TAPE/FINISH COAT(S) b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN L AREAS AND COMMON AREA. FLOORS AL BE SWEPT IM VACUUMED DAILY. - NOTE:AT EXTREMELY DARK ACCENT WALLS PROVIDE LEVEL 5 FINISH. ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. - 12.COMM E ADEQUATE PROTECTION,BALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO 9. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL SHOWN ON PLANS. - FILED WITH PACTRUST. BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION 15.PROJECT CLOSE OUT DOCUMENTS REQUIRED: ACTIVITIES. 09 53 00 SUSPENDED ACOUSTICAL CEILING 13.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING 1. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. O O RESTROOM FACILITIES. 2. TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL OVER THE ENTIRE SPACE. b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. cr) 14.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED ATc. HARD COPY OF AutoCAD FILE ABOVE PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER 3. BENT OR DAMAGED T-BARS TO BE REPLACED.. . c COMMON BUILDING AREA BE USED FOR STORAGE. 4. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING TSTATS. 15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ACCEPTABLE. e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. cuT 16.CONFIRM SIZES OF ALL OPENINGS'REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, 09 68 00 CARPET 26 00 00 ELECTRICAL: DESIGN I BUILD Z Q N ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 1. BROADLOOM GENERAL h 17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. 2. USE SCHLUTER TRANSITIONS PER FLOOR TRANSITION DETAILS. i, ALL ELECTRICAL FEEDS TO OUTLETS,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR O Q. 18.CLEAN ALL SUPPLY AND RETURN DIFFUSERS AT PROJECT COMPLETION. 09 91 23 PAINTING HORIZONTAL RUNS UNDER WINDOWS AND RECEPTACLES ON THE SAME STUD. Cy O O Lo 19.UPON COMPLETION OF THE PROJECT,THE CONTRACTOR MUST PROVIDE A DETAILED CLOSEOUT PACKAGE INTERIOR: 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING W � PER INSTRUCTIONS INCLUDED IN THE CONSTRUCTION CONTRACT.RETENTION WILL BE HELP PER CONTRACT SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. c: U) D m I` UNTIL THE COMPLETED CLOSEOUT PACKAGE IS RECEIVED AND HAS BEEN APPROVE BY THE CONSTRUCTION 1. WALLS: > Z I I MANAGER,ARCHITECT,AND PROPERTY MANAGER. 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. > a. PRIME NEW DRYWALL WITH MILLER PAINT HIGH-BUILD"SUPER SEAL"PRIMER. g f� 04 20.17 IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT 4. PROVIDE TYPEWRITTEN UPDA-,F 0 O SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. . co FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED 1204-XX WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER PAINT 170-5-XX S/G 5. VERIFY ELECTRICAL METER AND 1AG METER WITH THE TENANT'S ADDRESS OR SUITE NUMBER. METER Ln M co TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF LATEX ENAOEL. IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO - CO O Ip p WHETHER OR NOT SHOWN ON THE DRAWINGS. TENANTS MOVE-IN. 2. DOORS AND FRAMES: D_ �%�% 21.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL.SPRAY OR 6. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN ON PLAN EQUAL TO 22."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME ROLLED APPLICATION. 1-FOOT CANDLE. PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. 4. 7. EXIT LIGHTS:LITHONIA EDGR-G-EL RECESSED MOUNT,GREEN LETTERS.(CLASS A BUILDINGS) I,- ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEEL.L.SPRAY OR ROLLED APPLICATION 23.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS iS TONDO,SAND AND PRIME PATCHES WITH 8. FOR FLOOR POWER AND DATA ACCESS. `- 24.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN c. WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH PAINTER'S a. AT RAISED SLABS:USE WIREMOLD RC7 FLUSH POKE-THRU SERIES OR EQUAL. t71 TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX CAULK, _0 REPLACEMENT AT CONTRACTOR COST.AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL b. AT SLAB ON GRADE:USE WIREMOLD RFB4E BOX WITH 6CTC2 COVER AT CONFERENCE ROOMS m AND FINISH WITH SATIN OIL ENAMEL. AND 6CFFTC COVER AT FURNITURE FEEDS.PROVIDE 1"CONDUIT FOR POWER AND 2"CONDUIT FOR REQUIREMENT N PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE d. WOOD-STAIN,SEAL AS REQUIRED,AND VARNISH WITH SATIN VARNISH. DATA. CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS DIRECTED AT CONTRACTOR'S COST. 3. CEILINGS: 9. LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA)BY FUTURE TENANT. N 25.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPCT PPIME AND FINISH TO 10.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. (Uj PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT 6200 OR 4480. 11.OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. Q_ SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE b. NEW GYP BOARD/PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE:INIFORM COVERAGE COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR.SUBMITTALS MAY BE DELIVERED IN PDF 12.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT --- ---- FORMAT FOR REVIEW. WITH MILLER PAINT 6200 OR 4480. AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND -- -- --- --- - - 28.THE DESIGN FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS 4. GENERAL NOTES: CONTRACTOR.R. SPECIFICATIONS. SEQUENCES OF-OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE SpRgy, 13.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO FINISH SPECIFICATIONS. CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. 14.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY a DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS.RUBBISH,CANS,AND DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION THE ARCHITECT PRIOR TO INSTALLATION.SUBMITTALS MAY BE DELIVERED IN PDF FORMAT FOR REVIEW. RAGS AT THE END OF EACH DAV. ' OF THE EXISTING LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING_.. 27.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE d. UPON COMPLETION OF WORK,CLEAN AN) PAIi'T SPLATTER BY USING PROPER METHODS OF WASHING OFFICE LIGHTING INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. AND SCRAPING,USING CARE NOT TO SCRAi CH(,.-DA;-AGE FINISHED SURFACES. 1. OFFICE LIGHT FIXTURES-LITHONIA 2PM3N G B 3 32 1 BLD MVOLT ADVANCE OR EQUAL.(NO SYLVANIA 08 10 00 DOORS AND WINDOWS e. PROTECT WORK OF OTHER TRADES. L I `F . ( BALLASTS) - 1. RE-USE EXISTING DOORS,HARDWARE,AND FRAMES WHERE POSSIBLE. I. PROVIDE"WET PAINT"SIGNS AS REQUIRED TO PROTECT NENLY PAINTED FINISHES. 2. OFFICE EGRESS LIGHTING:ISOLITE MINI GENIE SERIES LED VERSION LMIGN NM SQ-CEILING AND WALL 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: 12 00 00 FURNISHINGS MOUNT. SEE PLAN FOR EGRES PATH. USE OF ISOLITE INVERTER AS ALTERNATE TO BATTERY IS ACCEPTABLE. a. BAXTER AND FLAMING. (503)225-0486 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS b. D&D DOOR 503)205-5533 1 3. LIGHT SWITCHES:ACUITY CONTRAST PRE SET ALL PRIVATE(`EPICS AND CONFERENCE ROOM SWITCHES TO ( 21 00'00 FIRE SUPPRESSION : /BUILD "VACANCY"AND TO TURN ON AT LAST DIM LEVEL.SET TIME-O:.'TO MAXIMUM. c. BENSON INDUSTRIES (503)907-2200 °' 1. ADJUST EXISTING SPRINKLERS THROUGHOUT SPACE AS REQUIRED BY CODE. SPRINKLER HEADS, HAL. BE a. ' STANDARD WALL SWITCH WITH OCCUPANCY SENSOR-USE'NSU - d. GRANT SUPPLY (360)887-0647 CENTERED IN 2 X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN \LL i LARD b. WALL SWITCH WITH OCCUPANCY SENSOR AND DIMMING USE WSXD - 3. DOOR AND RECITE FRAMES SHALL BE WESTERN INTEGRATED MATERIALS IM,OR APPROVED. SUBMITTAL CEILING AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO INSTALLATION. c. WALL SWITCH WITH DIMMING AND CEILING MOUNTED OCCUPANCY SENSOR-USE SPOD REQUIRED PRIOR TO ORDERING MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. 1 � i - 4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, 2. IN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC MOVEMENT. FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. NO OOPS RINGS ALLOWED. . 5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. 23 00 00 HVAC: DESIGN /BUILD 6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O.USE SPARTA AT NEW GAS METER BUILDING SUITE ENTRIES. 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. 7. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5"BACKSET. METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO TENANT'S MOVE-IN:v I. W 8. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR HVAC-BID PROCEDURE IN. Nb HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W1 STAIN AND FINISH C APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN I..L SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS PROPER WORKING ORDER. ";I. Fs I . PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL EL SAMPLE2. INVENTORY EXISTING H V.A.C. ROOFTOPUNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH UNIT O 3. LIST TONNAGE OF EAG i 9. ALL INTERIOR GLAZING SHALL BE TEMPERED. UNIT. 10.IN ALPHA ALUMINUM CLEAR ANODIZED PRODUCTS USE GRAY SEALS.MATCH IF EXISTING.ALL OTHER HVAC CONDITIONS USE BLACK. -DESIGN PROCEDURE ` - � � - +� i'• �'- - 1 11.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STOREFRONT WINDOWS AND DOORS.TOUCH UP 1. USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS W O FINISH FOR AS NEW LOOK. LISTED BELOW. 2' 12.TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK. 2. PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR qL Z REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH 09 00 00 FINISHES NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. GENERAL INCLUDE THE FOLLOWING: Q U Y r ` UCTING AND SIZES i. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR a. DS W d N TO INSTALLATION OF NEW FLOORING. b. SUPPLY AND RETURN LOCATIONS AND CFM AT EACH GRILL OR DIFUSER ,, F,I .,� I.- Q N 2. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS.EXCLUDES LVT AND c. ROOF EQUIPMENT,SIZES AND LOCATIONS 'L _ _ 0 + O SOME VCT APPLICATIONS.VERIFY WITH ARCHITECT PRIOR TO APPLYING WAX COATINGS. d. UNITS REQUIRING DUCTED SMOKE DETECTION O 3. EXISTING VCT TO REMAIN TO BE STRIPPED AND APPLY NEW WAX COATING. e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH -- T , 0- 00 4. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS L.. 'V. O c a. FLOOR COVERINGS,BASE AND TRANSITION STRIPS b. PLASTIC LAMINATES 9. ZONE DIAGRAM -i-" 0 U, ,. � Z HVAC DESIGN STANDARDS L.L U U) Q c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: �' W CD I- d. PAINTL•. _ q: (.,) Loo 1. 350 SQUARE FOOT PER TON(UNLESS OTHERWISE APPROVED IN WRITING BY PACTRUST). --, - - Lo e. TILE,MARBLE,GRANITE,STONE,GROUT AND SCHLUTER TRIM2. ADDRESS LOADS BY SPECIFIC LOOATIONAND USE,AS WELL AS CRITERIA PROVIDED TO PACTRUST BY- r. fE . 5. FINISH FLOORING TO EXTEND UNDER ALL NEW CASEWORK. TENANT PRIOR TO CONSTRUCTION: 'I' T o d d 6. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET PER TRANSITION a. EXTERIOR EXPOSURE AREAS DATE. 7/28/20 STRIP DETAILS. I'` b. INTERIOR AREAS,SIZE AND USE 1 PERMIT 7. PROVIDE SCHLUTER METAL TRIM AT ALL EXPOSER EDGES OF TILE(EXCEPT AT BULLNOSED EDGE) c. CONFERENCE/TRAINING ROOMS _ , 09 2100 GYPSUM BOARD 11 �,^,�s i d. COMPUTER I SERVER AND TELEPHONE ROOMS TO HAVE PRbYISION FOR LOW AMBIENT OPERATION GENERAL ._E D AND 24-HOUR USE.VERIFY NEED 1 FOR A SEPARATE SPLIT SYSTEM TO MAINTAIN TEMPERATURE. _ REVISION 1. ALL GYPSUM BOARD WALLS: ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHT ANGLES OR 3. SYSTEM DESIGN CRITERIA-SIZE ZONE$FOR 3,5 TON UNITS BASED ON USE&EXPOSURE CRITERIA PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"0!0.r FASTEN WITH 1"TYPE S PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS AND VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE 1. INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING), ZONES. "A EACH SIDE AND OPPOSITE SIDES. 4. ALL ENCLOSED ROOMS OR OFFICES 10 HAVE DUCTED SUPPLY&RETURN GRILLES. ' 2 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN 5. HVAC UNITS EQUAL Tb OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORSAND BE CONNECTED FINISH COATS(LEVEL 4 FINISH). PAINT AS INDICATED. TO A MONITORING STATION WITHIN THE BUILDING. 4 -I. 3' 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH 6..ECONOMIZER TO MEET CODE AND AS FOLLOWS: ..I ��- '"- �' 4, COAT(LEVEL 3 FINISH). PAINT AS INDICATED. 4. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. METAL STUDS. b. BAROMETRIC RELIEF ON 5-7 1/2 TON UNITS. li 5. 5. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT.QUIETJOINT SHH WHERE WALL c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. \' 6. MEETS MULLION AND EMSEAL WHERE WALL MEETS GLAZING.COLOR SELECTED BY ARCHITECT. d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. 6. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND 7, ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. 7• PATCH HOLES READY FOR PAINT. 7. REPAIR GYPSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR 8. DISTRIBUTION DUCTWORK: 'I 4' - 8. PAINT. a. SPIRAL DUCT PERMi 7TED ONLY IF EXPOSED. -II i 8. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. b. 26 GAUGE OR TO SMACNA STANDARDS_WHERE 666 N-CONCEALED ABOVE A CEILING. WALL CONSTRUCTION MATERIALS c. WRAP CONCEALED SUPPLY DUCT WORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH DRAWN BY: MINIMUM R4.2 INSULATION WITH FSK BAP.RIER. R.M.T. INSTALLATION. 1. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"',.MDL STR.'P. EXPOSED DUCT MUST HAVE ALL THREAD - �'2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED ON PLANS WHERE PHYSICAL HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LAi .ER THAN 18"MUST HAVE SADDLE TYPE CLAMP. STRUCTURAL PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTO, US). TEES SHALL BE MAXIMUM OF 45 LIVE LOADS. DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. DEGREES. 3, COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. PSI G60. ' - ) g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR 9, FLEX DUCT WILL BE NO LONGER THAN V FROM RIGID DUCT DOWN TO DIFFUSER. AN APPROVED EQUAL. .I 10.DIFFUSERS: 5. STANDARD GYPSUM BOARD SHALL BE TYPE W,5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM F C-38. a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESi'N A� 2 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. C-630, :b. GYPSUM BOARD CEILING;SUPPLY-CURVED BLADE WI OBD DESIGN TITUS 250;RETURN-BAR TYPE- DESIGN TITUS 350;EXHAUST:METAL OR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN TITUS 50F. f #3082 _ _ _� MARTIN W. HANSON �-j L___—_--__ s..___� f —I — / �— ED •lo—J e I � it 1 II LAN FILE/COPY BREAK - V - + - ED „s D T t,3 tt5 T� ' 9CLA KAM S,OREGON ~. FILES STORAGE Ns C7PIF.R tts E,. _ -.NOF t7t CIRC. 6 ':'! _ • I��. FES+ tt4 . � T " , -• • ® ,. ..: PROJECT #20380 yPA ♦ - ®_ 6A 18'BELOW I' SCREEN — .� • FRTURES RELOCATE DOOR " - CEILNG FROM RELINQUISHED I 1 �� SPACE CIRC. CONFERENCE - OFFICE '1 II y �a OFFICE toe tm ._ stns - _... k�4 � DEMO WALLAND PATCH �� a a e b b CARPET 5 e L • Q OFFI� CIRC. DEMO GLASS DOOR/WALL $PIR HVAC AND ELECTRICAL CONSTRUCT NEW WALL--� AT NEW DEMISING WALL pp -� ``,, 109 102 . . ,1—s'-- Vf . • . 1At y T o r I / c�/� o I: -I_ c RECEPTION OFFICE OFFICE OFFICE 1 701 103 104 105 - • _ _ • , • • i = a N 0 CD ry � LU Lr) TOUCH UP PAINT / - AREA RETAINED ELINQUISHED -- - THROUGHOUT AREA, N C U Cfl Z t4 BELOW AREA � g - AREA RETAINED RELINQUISHED M F- o 0 cEar7c R 140 _-I�-- 110 • 140 110 _ +48 SF ^4 SF 3,146 SF 984 SF Lp ,� V Lo Lo 2 ------------- A-3 1 PARTITION AND POWER PLAN 2 REFLECTED CEILING PLAN z SCALE 1/8" = V-0" SCALE 1/8" = 1'-0" 'o � A-3 m TENANT IMPROVEMENTS TO INCLUDE • TOUCH PAINT THROUGHOUT AS NEEDED • CLEAN CARPET c) U CIL FINISH MATERIALS - ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. FINISHES LISTED HERE ARE FOR REFERENCE FOR MATCHING EXISTING. NOT ALL FINISHES WILL NEED TO BE USED. CARPET LOOP PILE: LP-1 PATCRAFT 10129- NIGHT MOVES, 29515 COVERT OPERATIONS, DIRECT GLUE LP-2 PATCRAFT 10203-COLOR CHOICE, 00530 GREY METAL, DIRECT GLUE SLATE TILE ST CONTRACT FURNISHINGS MART (CFM) ST/OTM/658G MONTAUK BLACK GAUGED GT LATICRETE 45 RAVEN (II) BASE ' RF FLEXCO 4" FLAT RUBBER BASE, 038 OUTER BANKS AT ALL CARPET AREAS RC FLEXCO 4" COVE RUBBER BASE, 038 OUTER BANKS AT ALL HARD SURFACES. - - PAINT: ._ PT-1 MILLER 1450 ACRO PURE INTERIOR SATIN, 0195 MOSSY SHADE (FIELD) PT-2 MILLER 1450 ACRO PURE INTERIOR SATIN. 0588 BABBLING BROOK(FIELD ACCENT COLOR) - PT-3 MILLER 1450 ACRO PURE INTERIOR SATIN, 0591 BLUE JACKET (ACCENT STRIPE) - PT4 MILLER 1450 ACRO PURE INTERIOR SATIN, 1026 CASA DE ORA(ACCENT STRIPE) DOORS, HARDWARE AND FRAMES I - HARDWARE 628 ANODIZED ALUMINUM (INCLUDING CABINET PULLS) Z FRAMES PAC RED j wLUo W z 0 wav N I _ 0 0 iT � oC% 0 W 0 U) 0U) g LL W O F- � L0W I CONSTRUCTION LEGEND a 't . 33- 0 EXISTING TO REMAIN DATE: 7/28/20 DETAIL GENERAL NOTES: _ 20GA35/8" METAL STUD BRACING TO ROOF r-===7z= EXISTING TO BE REMOVED PERMIT 1. FOR WALLS UP TO 14-0"TALL, USE 362S125.30 MTL. STUDS @ 24"O.C.UNLESS STRUCTURE AT 10'-0"OC TO BUILDING STRUCTURE .. a NEW STANDARD WALL REVISION CALLED OUT OTHERWISE IN DETAIL. USE 3627125-30 MTL. TRACK. 2`-0" 2'-0" ABOVE FOR WALLS LONGER THAN 12'-0"WITHOUT " a, INTERSECTION WALLS. FASTEN EACH END WITH ACOUSTICAL BLANKET ABOVE GRID. KINETICS ® a NEW STANDARD WALL WITH INS. 2. FOR WALLS OVER 14'-0"TALL, USE 6005125.33 MTL. STUDS @ 16"O.C. UNLESS (1)#8 SHEET METAL SCREW KNM 100RB. TAPE WITH 3M 3015VP TAPE. SEAL CALLED OUT OTHERWISE IN DETAIL. USE 6007125-33 MTL. TRACK. CEILING TILES 1 DUPLEX RECEPTACLE ELECTRICAL PANEL 3. ALL WALLS:ATTACH BOTTOM TRACK TO FLOOR WITH POWDER DRIVEN - -- SOUND INSULATION 4' CENTERED 20 GA 3 5/8" METAL STUD BRACING TO ROOF e 2 ANCHORS AT 24"O.C. OVER WALL STRUCTURE AT 10'-0" OC WHERE REQUIRED FOURPLEX RECEPTACLE O POWER J-BOX 3 4. IN WALLS WITH ACOUSTIC INSULATION, SET BOTTOM TRACK IN BED OF SEALANT. \ SUSPENDED CEILING ° DEDICATED OUTLET ® FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA 5. FOR WALL FINISHES, FLOOR FINISHES AND WALL BASE TYPE, REFER TO RACO STYLE RECESSED REVEAL HEADER. SUSPENDED CEILING 4' _ _ EXISTING ELECTRICAL TO REMAIN FEP FIRE EXTINGUISHER IN RECESSED CAB. PROJECT FINISH SCHEDULE. CONCEPT WALLS#1-487RDT 5. POWDER DRIVEN ANCHORS MTL. STUDS. T RACO STYLE RECESSED REVEAL HEADER. / FLOOR MONUMENT Wit SERVICES SHOWN Es FIRE EXTINGUISHER SURFACE MOUNTED STRUCTURAL SUPPORTING CALCS: 5/8" GYP. CONCEPT WALLS#1-487RDT SPECIAL OUTLET QT THERMOSTAT 6 H - COC MTL.STUDS. TEL/DATA MUD RING WITH PULL STRING 7 1. POWERS 0.300 HEAD (3/4" EMBED)0.145 SHANK DIAMETER -- CENTER LINE OF STUD 5/8"GYP. BD. BOTH SIDES 8. ALLOWABLE SHEAR=70 LBS a w f- w = — -- Z 0 CENTER LINE OF STUD 2. 12'-0"TALL WALL WITH CODE REQUIRED 5 PSF MINIMUM LATERAL r 0 a W /+ (WIND)LOADSHEAR=5PSF* 12'-0"/2=30 PLF a W -- CEILING LEGEND DRAWN BY: 3. ANCHORS AT 16"O/C / 3-1/2" BATT INSUL. IN SOUND ATTENUATION WALLS U) O -- - 3-1/2" BATT INSUL. IN SOUND ATTENUATION WALLS 2 X 4 FLUOR.T-8 3 TUBE FIXTURE R.M.T. SHEAR= 30 PLF ` 16"/ 12"=40 LBS / LL ® SUPPLY DIFFUSER PARABOLIC LENS 4. UNITY CHECK I` BOTTOM TRACK. ® RETURN DUCT 40 LBS/70 LBS =0.57< 1.0 OK 4' �— ISI 2 X 4 FLUOR.FIXTURE � BOTTOM TRACK. - 1®I PARABOLIC LENS/STEADY BURN BALLIST ® EXHAUST FAN 5. ANCHORS AT 24"O/C SHEAR=30 PLF'24"/ 12"=60 LBS / FINISH FLOOR-TOP OF SLAB RECESSED LED DOWN LIGHT(Ti TILE2SPRINKLER HEAD 6. UNITY CHECK 1 STANDARD SWITCH 60 IT /70 Lbs=0.86 < 1.0 OK y! FINISH FLOOR e EXIT SIGN(LED RED) ® OCCUPANCY SWITCH HORN/STROBE FIRE ALARM(WALL MOUNT) A� 3 3 GENERAL NOTES r4iiii'iiiiii WALL SECTION WITH SOUND INS. L :5:) WALL SECTION WITH SOUND INS. / CURTAIN 0 CEILING OCCUPANCY SENSOR 00 HORN/STROBE FIRE ALARM(CEILING MOUNT) A-3 SCALE 1" = 1'-0" A-3 SCALE 1" = 1'-0 3 SCALE 1" = 1'-0"