Loading...
Plans (83) PLM2018 -00188 RECEIVED Otak APR 2 3 2018 hL PLUMBING LEGEND PLUMBING CONNECTION SCHEDULE Pressure drop calculations (PSI) per UPC Appendix A CITY OF IGASD Otak Architects, Inc BUILDING DIVISION MARK FIXTURE W V CW HW REMARKS 808 SW 3rd Ave, Suite 300 BT-1 BATH TUB 1-1/2" 1-1/2" 1/2" 1/2" Initial pressure 100 Portland, OR 97204 AFF •.••••.••..•...•••.....•..••.••.. ABOVE FINISHED FLOOR — - - — (DCW) DOMESTIC COLD WATER BT-2 BATH TUB 1-1/2" 1-1/2" 1/2- 1/2- ADA, GRAB BARS 6" service to 30 ft @ 560 gpm @ 2psi/1 00 ft -0.6 Phone 503.287.6825 ARCH •.................................. ARCHITECTURAL Water meter 6" 560 m -4 Fax 503.415.2304 B.G. •.................................. BELOW GRADE - - (DHW) DOMESTIC HOT WATER CW-1 CLOTHES WASHER FITTING 2" 2" 1/2" 1/2" 6" Backflow preventer -4 — BTU ••-•...................••........•• BRITISH THERMAL UNIT — — — — HB-1 HOSE BIB 3/4" NON-FREEZE WITH VACUUM BREAKER 6" main service -5 4- � CAP. ••••••........................••••. CAPACITY - — (FND) FOUNDATION DRAIN pPROF C.I. .................................. CAST IRON LV-1 LAVATORY 1-1/2" 1-1/2" 1/2" 1/2" COUNTER MOUNT ROUND 4" building service 34 ft. @ 3psi/1 00 ft. -1 iI COMP. ••••••.............•••••......••••• COMPARTMENT (SAN) BELOW GRADE WASTE KS-1 KITCHEN SINK 2" 1-1/2" 1/2" 1/2" SINGLE COMPARTMENT WITH DISHWASHER Interior piping (275ft a max. 8psi/1 00 ft. -22 w 145 r CONT. ...............I..............•.... CONTINUATION Elevation 61 ft .43 psi/ft) -26 CU. ••••••.......I..........•-----..... CUBIC (SAN) ABOVE GRADE WASTE KS-2 KITCHEN SINK 2" 1 -1/2" 1/2" 1/2" SINGLE COMPARTMENT WITH DISHWASHER, ADA Minimumressure at remote fixture -20 DIA. ................................... DIAMETER " " ELEV. ELEVATION —V V— (V) VENT WC-1 WATER CLOSET 3" 2 1/2 FLOOR MOUNT, TANK TYPE Available excess pressure 17.4 °rrZ� lese FD ••••••........................••••• FLOOR DRAIN WC-2 WATER CLOSET 3" 2" 1/2" FLOOR MOUNT, TANK TYPE, ADA ( TORM FDC ••••••.......I..........••••.••••.. FIRE DEPARTMENT CONNECTION RD (RD) RAIN DRAIN SP-1 SUMP PUMP 2" 50 GPM, 1/2 HP, ELEVATOR SUMP EXPIRES: 3OJUN18 F.F. ••••••........................••••• FINISH FLOOR FLG. .. FLANGE OD (OD) OVERFLOW RAIN DRAIN FD-1 FLOOR DRAIN 3" VL SIOUX CHIEF FT STAMP •.................................. FOOT FEET FDC (FDC) FIRE DEPARTMENT CONNECTION RD-1 RAIN DRAIN 3" G •-......••••-..................•• GAS OD-1 OVERFLOW RAIN DRAIN 3" GA. ••••............................... GAUGE F (F) FIRE WATER GALV. ................................... GALVANIZED ON-1 OVERFLOW NOZZLE 4" GLUE ON NOZZLE GPM ................................... GALLONS PER MINUTE G.V. ................................... GATE VALVE WH-1 WATER HEATER 3/4" 3/4" 50 GAL., FHR 67, UEF .95 M Consulting Engineers 2007 S.E. As St. HP ................................... HORSEPOWER CO CLEAN OUT T kW """""""""""""""""' KILOWATT .................... PRESSURE/TEMP RELIEF VALVE wC0 WALL CLEAN OUT F y PHNIa(03) 234nd, OR 7 01548 LAV ................................... LAVATORY r1 LBS ................................... POUNDS Ill •••••.............•• BUTTERFLY VALVE V.L. - VENTED LINE INC.FAX:. 0 (50 ) 234- 677 MAX. ................................... MAXIMUM MBH ................................... THOUSANDS OF BTUs PER HOUR D� ...••.•.......•••.. GAS PRESSURE REGULATING VALVE CONTACT: Bryan Gregory MIN. ""•""•"•"'•'•"......"""" MINIMUM -o 0­0 .................... PIPE TURNED UP, PIPE TURNED DOWN CONSULTANT M.J. """"'•"•"••"'•••"•""""' MECHANICAL JOINT N.I.M. ..""""""""""••"•"""'• NOT IN MECHANICAL ..CT<1. ••••.--••-••••••. GATE VALVE PROT. ••••••......••-••-............••. PROTECTION PLUMBING CALCULATIONS BLDG 6 PRV '•"""""""""'•'•""""••• PRESSURE REDUCING VALVE . ............••• BALL VALVE DOMESTIC WATER SERVICE SANITARY WASTE SERVICE PSI, PSIG ••••••........................••••. POUNDS PER SQUARE INCH CITY OF TIGARD a" P T ••••••........................••••• PRESSURE TEMPERATURE ......-----••••. 0 / / BALANCING VALVE FIXTURE TYPE NUMBER WATER TOTAL TOTAL CW TOTAL HW DRAINAGE TOTAL REQ'D ................................... REQUIRED Approved............................... r� � ......••• ••• ......••-• •.... OF FIXTURES FIXTURE WSFU FIXTURE FIXTURE FIXTURE DFU TYP. TYPICAL -•{�� .................... CHECK VALVE Conditionally At,proved......----... [ J ................................. W VTR VENT THROUGH ROOF UNITS UNITS UNITS UNITS See Letter to: P,?i.:�� __... .......... I I WC ................................... WATER CLOSET -I I- .................... UNION Aiujmcd ------------..� ) . . DOUBLE CHECK ASSEMBLY BATHTUB or COMBO BATH/SHOWER 56 4 224 168 168 2 112 Permit Nwnber: PLMaol 0 0 Address:__' EfO 5,W, I"*.Ikar (l CLOTHES WASHER 56 4 224 168 168 3 168 X ""'•""""""•• CAP KITCHEN SINK (GRINDER& DISHWASHER) 56 3 168 126 126 2 112 BY (L) Ume: e1- 1 EQUIPMENT MARK NUMBER 6 LAVATORY(SINGLE) 56 1 56 42 42 1 56 XXX FIXTURE MARK RECEPTOR(ELEVATOR WASTE) 1 0 0 0 0 100 100 Q � TEE 0 """""""""" ...... RECEPTOR (INDIRECT WASTE) 1 - — --- 1 1 0 L ELBOW WATER CLOSET(1.6GPFTANK-PRNATE) 56 2.5 140 140 0 3 168 # NOTE QCLEANOUT HOSE BIBB (FIRST ONE) 1 2.5 2.5 2.5 0 -- X ................... RISER DIAGRAM NUMBER .................. HOSE BIBB (EACH ADDITIONAL) 5 1 5 5 0 TOTAL 288 819.5 651.5 504 717 GPM 182 WASTE SIZE 8 PLUMBING CALCULATIONS 1 BATH DOMESTIC WATER SERVICE SANITARY WASTE SERVICE Z L1J W FIXTURE TYPE NUMBER WATER TOTAL TOTAL CW TOTAL HW DRAINAGE TOTAL J OF FIXTURES FIXTURE WSFU FIXTURE FIXTURE FIXTURE DFU Q UNITS UNITS UNITS UNITS L1J BATHTUB or COMBO BATH/SHOWER 1 4 4 3 3 2 2 F- U o CLOTHES WASHER 1 4 4 3 3 3 3 a U) (n KITCHEN SINK (GRINDER& DISHWASHER) 1 3 3 2.25 2.25 2 2 J J LAVATORY(SINGLE) 1 1 1 0.75 0.75 1 1 Q z WATER CLOSET(1.6 GPF TANK-PRIVATE) 1 2.5 2.5 2.5 0 3 3 Q _ 0 �/� m TOTAL 5 14.5 11.5 9 11 V/ Z Q M GPM 11 WASTE SIZEco Wrn LL CL N Z W ryr _ � c F- w I— m TITLE # DATE DESCRIPTION REVISIONS BKG JILT DRAWN BY CHECK BY PERMIT SET STATUS 04.18.18 DATE 17052 PROJECT NUMBER P0 . 01 ©2017 OTAK, INC. If this drawing is not 24"x 36",it has been reduced/enlarged. Scale accordingly. Otak �� ► Otak Architects, Inc 808 SW 3rd Ave, Suite 300 Portland, OR 97204 Phone 503.287.6825 Fax 503.415.2304 4-18-18 PR"D�-`r� 14,5 r GENERAL NOTES KEY NOTES 4 1. WORK SHALL COMPLY WITH CURRENT O CONNECT 2" ELEVATOR SUMP PUMPRoby 2� 'y59 OREGON PLUMBING SPECIALTY CODE. TO 4" CONNECTION fs C. TORN 2. COORDINATE INSTALLATION WITH OTHER 0 3' RADON VENT UP TO ROOF EXPIRES: 30JUN18 TRADES. 3. SEE TYPICAL UNIT PLANS FOR WASTE O PROVIDE 3" HUB DRAIN FOR FIRE STAMP RISERS. SPRINKLER DRAIN 4. ALL PIPING IN EXTERIOR WALLS TO BE INSTALLED ON WARM SIDE OF INSULATION. Consulting Engineers AI5. PROVIDE TRAP PRIMER ON HUB DRAIN. 2007 S.E. Ash St. Portland, OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 INC.WWW.MFIA-ENG.COM CONTACT: Bryan Gregory CONSULTANT - - - - - - - - - - - — — — — — — — — — — - - - - - - - - - - — — — — — — — — — — z I I I I STAIR 1 11 I i t i FU l 1 I I Q 5117 - - - - - `�— - - - - - - —+ - - � - - -UNIT 2 BED UNIT 1 BED UP --- UNIT 1 BED - UNIT 1 BED - NIT 2 BED I UNIT 1 BED , UNIT 2 BED I 0 --- TYPE A TYPE A I z 5101 I 5-103 I ___ I ( I 5109 I 5111 I 5 5113 1 © e lLLI --------------_ I _--------------__ l e I- z Z - — © i , i (/) �_ s I N a 4 8 5 a I ^ J F— a a I i I 4 SP-1 l y 6 9 I , = I I 1 Ii Q Q i I s.a I I O I i O I i I7 0 4„ 6" SAN - - - - Cp C RRIDOR — I – – I - - — — - - - - N Q M 2 0 7 -115 CO i Q N U_ — — — —6" SAN— 4" SAN 4" — — — co CN w ILLI ' ' I C� I I I ;X�. � I I I I i l i LU ? , ! 3 , N 0 Z , I n I = ( I W �n I I , I z 0 p I — --- , W 5Q' ------- --------- - --- - e o U) m BELOW FF I --3 I I _ 1 I J 2 I I ; 5 2 6.0 2 I ___ - 8 a TITLE UNIT 2 BED - I UNIT 2 BED I UNIT 1 BED I UNIT 2 BED I UNIT 1 BED i UNIT 1 BED I –_- I UNI 1 BED I TYPE A I a DATE DESCRIPTION 5102 I 5104 I 5106 I 5-108 I 5110 3 5-112 I 5-114 1 -- UP - - - - I - - — — — — — —+} - - I �TAIR2 I I I I II I I I I I 110 5 116 I I 5.D - - - - - -- - - - - - - - - - - - - - - - - - - --- - — — — — — -- - - -- - -- - - - - - - - - - - - - - - - - - i - - - - - _ - - - - - - - - - - - - - - - - - - - — — — — — — — — - - - - iI I I I I ( I I REVISIONS 8" SAN SEE CIVIL J I " 4" FND SEE CIVIL I 4 DCW SEE CIML BKG JILT 'FOR CONTINUATION FOR CONTINUATION FOR CONTINUATION , , DRAWN BY CHECK BY I .=4.75' BELOW FF PERMIT SET STATUS 04.18.18 DATE 1 FOUNDATION PLUMBING PLAN 17052 5-2,00 SCALE: 1/8" = 1'-0" PROJECT NUMBER P5=2000_ ©2017 OTAK, INC. LZ If this drawing is not 24"x 36",it has been reduced/enlarged. Scale accordingly Otak Otak Architects, Inc 808 SW 3rd Ave, Suite 300 Portland, OR 97204 Phone 503.287.6825 Fax 503.415.2304 4-18-18 W 14,5 r GENERAL NOTES KEY NOTES ��s c. ZTO'R ' 1. WORK SHALL COMPLY WITH CURRENT 01" DCW TO UNIT AND 1 1/2" DCW EXPIRES: 30JUN18 OREGON PLUMBING SPECIALTY CODE. UP TO FLOOR ABOVE 2. COORDINATE INSTALLATION WITH OTHER O2 3' RADON VENT UP TO ROOF STAMP TRADES. O4" COMBINATION RAIN AND 3. SEE TYPICAL UNIT PLANS FOR FIXTURE 3 OVERFLOW DRAIN UP BRANCH PIPING. IYISLI ' nA� 4. ALL PIPING IN EXTERIOR WALLS TO BE a5 pe_,r See-. 1101, 12 .22L, • cc m 6:r�ar� Sys +e� s M Consulting Engineers 2007 S.E. Ash St. INSTALLED ON WARM SIDE OF INSULATION. OPX FI Portland, OR 97214 A PHN: (503) 234-0548 5. UNIT FIXTURE BRANCH PIPING IS 1/2" FAX: (503) 234-0677 UNLESS NOTED OTHERWISE. INC.WWW.MFIA-ENC.COM CONTACT: Bryan Gregory CONSULTANT I I I I I I I I I I I I I I I I I I I I I I ' HB- ' HB-1 5.A - - - - - - - - - - --- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - � I =STAIR 1 1 I I � I I � 2-7 Q D F— J UNIT 2 BED I UNIT BED UP --_ UNIT 1 BED - I UNIT 1 BED - UNIT 2 BED I I UNIT 1 BED , UNIT 2 BED Z TYPE A I TYPE A I 5-109 I I 5-111 I 5 5-113 W -_-_- , 5-105 , 5-107 , , C z _ WH-1 I G WCO KS-1 2 I r-- I --- I I I 2 i I I 2 � — y i WH-1 I i �-- t 1 WCO m © FC W_ 8 I CW-1 - I I CW-1 5 I ----------- CW-1 1 ( - 1 I I --------------- - I © LL o HB-1 i K -1 �i i i U J _ ; I I ;-- I ; KS-2 BT a KS-2 I 8 I 3 I Q J 1 5 , WH-1 ' � I WC-1 LV-1 6 LV-1 9Lij 4 I I WC-2 I I I VQ i© © i p M w 6.0 2,. DCW --- 2 1/2" DCW - --�- --2 1/2" DCW ----- 3" DC 1-- ---�-�{�-- — 7 - - 3" DC�J—�{�--- - {�Af�4" DCW # - 2 1/2" D;W - ----2" DCW 1 (n ~ LJCj i 1 i 1 1 1 1 I I' t 2 5-115 1 LU _ W N o z I U t - , X . I I I LV-, Zo 0 I � W � 3 I ; W � w J KS-1 '/: CW-1 WH-1 WC-1 I I w u� I I I W 2 = < ' -- BT-2 ---- - -------- - ---------------- -------------- e I I TITLE o I - II 5 WCO 2 � � 2 i I =-- - I i I e CW-1 KS-2 WCO � DATE DESCRIPTION 1 2 UNIT 2 BED - UNIT 2 BED I UNIT 1 BED I i UNIT 2 BED g p UNIT 1 BED I UNIT 1 BED I I i UNI BED I TYPE A 5-102 I 5104 I i 5 106 I 5-108 I 5-110 I =_= UP I I 5112 I 5114 STAIR 2 6.0 0 5 116 - - - - - - - I FH—B711 I HB-1 3 3 3 3 i 3 3 3 REVISIONS ON-1 ON 1 I ON-1 ON 1 I 6.0 ON-1 3 ON 1 i ON-1 i ON-1 BKG AT DRAWN BY CHECK BY I I I I I I I PERMIT SET STATUS 04.18.18 DATE 17052 1 LEVEL 1 PLUMBING PLAN PROJECT NUMBER 5-2,01 SCALE: 1/8" - 1'-0" P5m2m01_ ©2017 OTAK, INC. d LL If this drawing is not 24"x 36",it has been reduced/enlarged Scale accordingly tt Otak �Am � ► Otak Architects, Inc 808 SW 3rd Ave, Suite 300 Portland, OR 97204 Phone 503.287.6825 Fax 503.415.2304 4-18-18 PR W 14,5 r GENERAL NOTES KEY NOTES Cy 26, %989 1. WORK SHALL COMPLY WITH CURRENT O1 1" DCW TO UNIT AND 1 1/4" DCW �s 4. TOIR OREGON PLUMBING SPECIALTY CODE. UP TO FLOOR ABOVE EXPIRES: 30JUNt8 2. COORDINATE INSTALLATION WITH OTHER O2 3" RADON VENT UP TO ROOF STAMP TRADES. O3 4" COMBINATION RAIN AND 3. SEE TYPICAL UNIT PLANS FOR FIXTURE OVERFLOW DRAIN UP BRANCH PIPING. 4. ALL PIPING IN EXTERIOR WALLS TO BE M Consulting Engineers INSTALLED ON WARM SIDE OF INSULATION. '007 S.E. Ash St. F I Portland, OR 97214 5. UNIT FIXTURE BRANCH PIPING IS 1/2" /� PHN: (503) 234-0548 UNLESS NOTED OTHERWISE. r1 FAX: (503) 234-0677 INC.WWW.MFIA-ENG.COM CONTACT: Bryan Gregory CONSULTANT I I I I I I I I I I I 1 I i STAIR 1 5-217 U) Z v♦ UNIT 2 BED I UNIT 1 BED UP DN UNIT 1 BED I UNIT 1 BED i UNIT 2 BED I UNIT 1 BED I UNIT 2 BED 5-201 ' 5-203 ' 5 205 5 207 5 209 5-211 5 5-213 Z 0— I I I i 2 i 2 W z 2 KS-1 I i-- I I 2 ;-- I ;-- ;I I -- I — CW-1 m 8 I 5 I I 1 I I O ZD F-- U) J s � a J I WH—t I , ° I 3 i Q N WH-1 l 5 I 4 I a \ I W -1 I 5.B - - - - -- - - - - - - - - - - - - - - - - - LIJ z Q > CORRIDOR M W 1 2 ~ C'4 J 5215 I I I I J I I I ■ ■ ■ cj� m O T I ,x, I O I (DI N p z I � � I I 1 ; Q n, , KS-1 -/ CW-1 WH-1 W -1 I t o I I L U = Q U) H m I I I 4 I i i 2 I I I i ---- - I TITLE I , I � 5 1 O 2 2 I ( 1 2 # DATE DESCRIPTION UNIT 2 BED ( UNIT 1 BED I UNIT 2 BED UNIT 1 BED UNIT 1 BED I I UNI BED I UNIT 2 BED 5-202 5-204 ' 5 206 I 5-208 I 5 210 I ' S 212 ' 5 214 II DN UP I ' ' STAIR 2 l 0 5-216 I I I I I 3 3 3 3 3 3 I 3 ( 3 i I I I i REVISIONS BKG JILT i DRAWN BY CHECK BY PERMIT SET STATUS I I I 04.18.18 5.5 DATE 5. 1 5.2 5.3 5.7 5.9 . 1 5. 1 1 17052 1 LEVEL 2 PLUMBING PLAN PROJECT NUMBER 5-2.0 SCALE: t $ - 11-0. P5-2 . 02 ©2017 OTAK, INC. LL If this dewing is not 24"x 36",it has been reduced/enlarged Scale accordingly. o' Otak �� ► Otak Architects, Inc 808 SW 3rd Ave, Suite 300 Portland, OR 97204 Phone 503.287.6825 Fax 503.415.2304 a-,e-1e v��fi�GD PNOFF��-b `v 14,5 GENERAL NOTES KEY NOTES f�✓G(Y 2 � �yg9 1. WORK SHALL COMPLY WITH CURRENT 01" DCW TO UNIT AND 1" DCW UP TOR�� OREGON PLUMBING SPECIALTY CODE. TO FLOOR ABOVE EXPIRES: 30JUN18 2. COORDINATE INSTALLATION WITH OTHER O2 3' RADON VENT UP TO ROOF TRADES. STAMP O3 4" COMBINATION RAIN AND 3. SEE TYPICAL UNIT PLANS FOR FIXTURE OVERFLOW DRAIN UP BRANCH PIPING. 4. ALL PIPING IN EXTERIOR WALLS TO BE INSTALLED ON WARM SIDE OF INSULATION. Consulting Engineers 2007 S.E. Ash St. F I Portland, OR 972t4 5. UNIT FIXTURE BRANCH PIPING IS 1/2" PHN: (503) 234-0548 UNLESS NOTED OTHERWISE. FAX: (503) 234-0677 INC.WWW.MFIA-ENG.COM CONTACT: Bryan Gregory CONSULTANT I I I I I I I I I I i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I STAIR 1 7 I 5-317 ♦♦^^ z I V♦ UNIT 2 BED I UNIT 1 BEDuP ' orv_ UNIT 1 BED I UNIT 1 BED I UNIT 2 BED I UNIT 1 BED I UNIT 2 BED QJ 5 301 i 5 303 i i 5-305 i 5-307 i 5 309 i 5 311 i 5 5-313 Z 0— Uj 2 I I 1 2 z K$—, J47- -r-- I r-- I I r I 1 © CW-, e I I 2 t I t � I 1 --------------- KS-, , I I - 5 I I ----- ----- r m I I I Q U'00 J J \ WH-1 I W —1 I I I I 4 3 I Q Cy')i t —' w I I Q� I © I t � � � Cl)V/ 5. B - - - - - - - - - —\- - - - - - - - - - -- - > C DOR 1 Q a N W CN W Ln I I I O I I I I I I � I I I Y E C7 — - w I �X I I U' I i N 0z I KS-1 ,/%' CW-1 WH—1 W —1 I I p I W 5 D_ 0 I I I l U) H F- m 4 -- __-- - - LH I -- 1 ' -- ' --' 2 5 I 1 TITLE 2 2 1 p UNIT 2 BED I UNIT 1 BED I UNIT 2 BED ' UNIT 1 BED ' UNIT 1 BED ' ( UNI BED I UNIT 2 BED # DATE DESCRIPTION 5-302 I 5-304 I 5-306 I 5-308 I 5-310 I I 5-312 I 5-314 ON UP ' I I � � I STAIR 2 1 ° 5 316 I I I I I 1 3 3 33 TT� 3 1 3 1 I REVISIONS BKG JILT 1 I I I DRAWN BY CHECK BY PERMIT SET I I I I I I I I STATUS 04.18.18 DATE 17052 1 LEVEL 3 PLUMBING PLAN PROJECT NUMBER 5-2.03 SCALE: 1/8" - 1'-0" P5-2 . 03 ©2017 OTAK, INC. LL If this drawing is not 24"x 36", if has been reduced/enlarged, Scale accordingly. Otak �� ► Otak Architects, Inc 808 SW 3rd Ave, Suite 300 Portland, OR 97204 Phone 503.287.6825 Fax 503.415.2304 4-18-18 W 14,5 r GENERAL NOTES KEY NOTESs 2Z. T ORM 1. WORK SHALL COMPLY WITH CURRENT Ol 1" DCW DN TO FLOOR BELOW EXPIRES: 30JUN18 OREGON PLUMBING SPECIALTY CODE. O2 3" RADON VENT UP TO ROOF 2. COORDINATE INSTALLATION WITH OTHER STAMP TRADES. O 4" COMBINATION RAIN AND 3. SEE TYPICAL UNIT PLANS FOR FIXTURE OVERFLOW DRAIN DN BRANCH PIPING. � rnskolt as timet Sec. 110t. 1x. .2 .2 2 Go�.6;n� SyS��S 4. ALL PIPING IN EXTERIOR WALLS TO BE OPSC M Consulting Engineers 2007 S.E. Ash St. INSTALLED ON WARM SIDE OF INSULATION. I Portland, OR 97214 PHN: (503) 234-0548 5. UNIT FIXTURE BRANCH PIPING IS 1/2" FAX: (503) 234-0677 UNLESS NOTED OTHERWISE. INC.WWW.MFIA-ENG.COM CONTACT: Bryan Gregory CONSULTANT I I I I I 1 I I I I I I I I i STAIR 1 5-417 I UNIT 2 BED I UNIT 1 BED I I UNIT 1 BED I UNIT 1 BED I 7 UNIT 2 BED UNIT 1 BED I UNIT 2 BED ~ CL 5-401 i 5-403 i DN i 5 405 I 5 407 I 5 409 i 5 411 i 5 5-413 W Ur ZD 1 Z 2 I E-- I I 2 8 ZD I L I I I 0 2„ V /^� a -- — VV J > Q ' I Q I > © I 1 ' > I 8 5 V O6 W Q I i i < I I V, z I I � _ —_— Q M w 4" VTR , , 7 , c0 w R , 1 1 3„ 3" 3" " V 3" I I 3" 3" V 3" V 2" V 2' 3" „ V 1 1 I 1 2 415 I 3° ' 3" V 3" 3" 3" L0 • W 4 �— Of O Ox; N I > > W z0 0 cli v z" v -------, I - I I I � � v z" v � � � m I I -J I I > e5 i TITLE 2 2 # DATE DESCRIPTION I I I 1 I UNIT 2 BED I UNIT 1 BED I UNIT 2 BED UNIT 1 BED ' UNIT 1 BED ' I UNI BED I 2 UNIT 2 BED 5-402 i 5 404 i 5-406 i 5-408 I 5 410 I i 5 412 i 5-414 DNEll I I I STAIR 2 I I 5-416 I I I I 1 I I 3 3 3 I 3 I 3 I 3 I 3 I 3 I REVISIONS I I I I I I BKG JILT DRAWN BY CHECK BY PERMIT SET I I I I STATUS I I 04.18.18 DATE 5. 1 5.2 5.3 5.5 5.7 5.9 . 1 5. 1 . 1 17052 PROJECT NUMBER 1 LEVEL 4 PLUMBING PLAN 5_2 04 SCALE: 1/8" = 1'-0" P5=2 0 04 ©2017 OTAK,INC. d LL If this drawing is not 24"x 36",it has been reduced/enlarged Scale accordingly. rr Otak �� ► Otak Architects, Inc 808 SW 3rd Ave, Suite 300 Portland, OR 97204 Phone 503.287.6825 Fax 503.415.2304 4-18-18 14,5 r GENERAL NOTES �� t ZTOR�� 1. WORK SHALL COMPLY WITH CURRENT EXPIRES: 30JUN 1 S OREGON PLUMBING SPECIALTY CODE. 2. COORDINATE INSTALLATION WITH OTHER STAMP TRADES. MConsulting Engineers 2007 S.E. Ash St, AI Portland, OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 INC.WWW.MFIA-ENG.COM CONTACT: Bryan Gregory CONSULTANT I I I I I I i i I I I I I I I 5.A -- - - - - - - - - - - - I - - - - - - -- Ii L------------------- IL----------------- I Cn Z Q w 0- z ® I I ® I I ® I ® j Lu c i I I I I a Q 0 aM 0 W � m LO LO 5.0 - - - - - - - - - - - - - --- -- - - ---- --- - - - - - - - - - - - - --, - - - - - - - - - - - - - - - - - - - - - - - - - LU 0 I � 1 V- N0 z i II I LU z � o ' _. J I I L_.._ ._ = Q I . I I I � � I = � U) m ® I ® I ® I ® ( ® I ® L TITLE i # DATE DESCRIPTION O -1Q� itI OD-1 O i D-1 O 0OD-1O OD-1 0OO -1 O O OD-1 QRD— Q RD-1 RD-1 Q RD-1 RD-1 Q Q RD-1 1 i REVISIONS BKG JILT DRAWN BY CHECK BY PERMIT SET STATUS 04.18.18 DATE 17052 1 ROOF PLUMBING PLAN PROJECT NUMBER 5-2,�5 SCALE: 1/8" = 1'-0" P5-2 . 05 ©2017 OTAK, INC. L If this drawing is not 24"x 36",it has been reduced/enlarged. Scale accordingly. rY Otak Otak Architects, Inc 808 SW 3rd Ave, Suite 300 1 1/2" V SEE P2.04 2" V SEE P2.04 Portland, OR 97204 2" V SEE P2.04 FOR CONTINUATION 2" V SEE P2.04 2" V SEE P2.04 FOR CONTINUATION Phone 503.287.6825 FOR CONTINUATION FOR CONTINUATION FOR CONTINUATION Fax 503.415.2304 4-18-18 5,���D PNOFFI' LV-1 V 4�14,5 KS-1 CW-1 r BT-1 WC-1 4r 2& X909 7 2" V 1 1/2" V 2" V FS C. T 0?- Fo�RTy 1 1/2" FQ�RTy 2 V " FQ�RTy 2\ V `.FO pRTy 2- IN W FOpRTy A EXPIRES: 30JUN 18 2" W FOO .FOO 3 W FOO £�pOC�pR STAMP KS-1 R LV-1 .R .R 1 1/2 W R CW-1 0 WC-1 BT-1 M Consulting Engineers 2007 S.E. Ash St. y `.Tye " .Tye 2" V Th FI Portland, OR 97214 2 V " T(Rp N .R " .R SRO /� PHN: (503) 234-0548 2 W `��OOR 2" W O F<OpR 2 V 3" W O F(0, 2" W .O FLOOR 2.. W rCapR INC.WWW.MFIOA)ENG.COM77 CONTACT: Bryan Gregory KS-1 LV-1 0 CW-1 BT-1 CONSULTANT IN WC-1 \\ 1 1/2- V 1 1/2- V 1 1/2" V 2" V 2" 2" V \\ QQ�P £ 2" W QQyp £ 2" W �pyP £C CpQR CQQR 3" W CgQR CQpR QpR 2" W " LV-1 " 2" W KS-1 2 W 4" W BT-1 2 W CW-1 WC-1 QQR QpR QQR QpR PR NOTE: DRAINAGE CONNECTIONS SHALL NOT BE MADE INTO A NOTE: DRAINAGE CONNECTIONS SHALL NOT BE MADE INTO A NOTE: DRAINAGE CONNECTIONS SHALL NOT BE MADE INTO A DRAINAGE PIPING SYSTEM WITHIN 8 FT OF ANY VERTICAL TO DRAINAGE PIPING SYSTEM WITHIN 8 FT OF ANY VERTICAL TO DRAINAGE PIPING SYSTEM WITHIN 8 FT OF ANY VERTICAL TO HORIZONTAL CHANGE OF DIRECTION OF A STACK CONTAINING A HORIZONTAL CHANGE OF DIRECTION OF A STACK CONTAINING A HORIZONTAL CHANGE OF DIRECTION OF A STACK CONTAINING A SUDS— PRODUCING FIXTURE. SUDS— PRODUCING FIXTURE. SUDS— PRODUCING FIXTURE. EXCEPTION: STACKS RECEIVING THE DISCHARGE FROM LESS THEN 3 EXCEPTION: STACKS RECEIVING THE DISCHARGE FROM LESS THEN 3 EXCEPTION: STACKS RECEIVING THE DISCHARGE FROM LESS THEN 3 STORIES OF PLUMBING FIXTURES. STORIES OF PLUMBING FIXTURES. STORIES OF PLUMBING FIXTURES. 1 RISER " 1 " TYPICAL DFU 8 2 RISER " 2" TYPICAL ( DFU 4) 3 RISER " 3" TYPICAL ( DFU 12 4 RISER " 4" TYPICAL DFU 8) 5 RISER " 5" TYPICAL ( DFU 12) 5.01 NO SCALE 5.01 NO SCALE 5.01 NO SCALE 5.01 NO SCALE 5 01 NO SCALE N 2" V SEE P2.04 1 1/2" V SEE P2.04 1 1/2" V SEE P2.04 Z FOR CONTINUATION FOR CONTINUATION 2" V SEE P2.04 2" V SEE P2.04 FOR CONTINUATION FOR CONTINUATION FOR CONTINUATION LU Q LV-1 LV-7 I..f. a- m Q - U _o a WC-1 WC-1 BT-1 Q � 2" V " 2 V 3" W FQ�RTy F 1 1/2" W FQ�RTy "\`\FD�RTy 2\ V FO pRTy 1 1/2"\W-0 pRTy �A a M w ,'Co�R '£Coon 3 w .£CoOR .£Coon , c�ooR C� LV-1 1 1/2" W LV-1 J W w ir WC-1 WC-1 BT-1 Y Z N _ TyN. 1/2 V `,,T '`.Ty ,T �`. T W 5 Q 2" V 3" W 'Rp y�Rp 2" V �Rp 2" V \` 'yiRp y!Rp = Q F�ooR 2" W .F(pOR 3" W ` <pOR 2" yy `"'40, R 2" yy F<pOR (` J 0) H 0— LV-1 IN LV-1 WC-1 �\ BT-1 TITLE WC-1 1 1/2" V # DATE DESCRIPTION 2" V \\1kQQ�p £ 1 2" w \' QQyp \\ QQ�p z"\w �Qyp 2" W \\\-kQQN0 CQpR £CQpR 3" W £CQQR £C p, FCQpR 3" W BT-1 T LV-1 WC-1 B -1 REVISIONS �� QpR QTR QQR QQR BKG JILT NOTE: DRAINAGE CONNECTIONS SHALL NOT BE MADE INTO A DRAWN BY CHECKBY DRAINAGE PIPING SYSTEM WITHIN 8 FT OF ANY VERTICAL TO HORIZONTAL CHANGE OF DIRECTION OF A STACK CONTAINING A PERMIT SET SUDS— PRODUCING FIXTURE. STATUS EXCEPTION: STACKS RECEIVING THE DISCHARGE FROM LESS THEN 3 STORIES OF PLUMBING FIXTURES. 04.18.18 DATE 6 RISER " 6 " TYPICAL DFU 13 7 RISER " 7" TYPICAL DFU 3 8 RISER " 8" TYPICAL DFU 9 ) 9 RISER " 9 " TYPICAL DFU 11 10 RISER " 10" TYPICAL DFU 5 17052 5.01 NO SCALE 5.01 NO SCALE 5.01 NO SCALE 5.01 NO SCALE 5.01 NO SCALE PROJECT NUMBER P5 . 01 ©2017 OTAK, INC. LL If this drawing is not 24"x 36",it has been reduced/enlarged. Scale accordingly. Otak �Aawlo' ► Otak Architects, Inc 808 SW 3rd Ave, Suite 300 V SEE Portland, OR 97204 2" V SEE P2.04 F 1 CONTINUATION 04 2" V SEE P2.04 Phone 503.287.6825 FOR CONTINUATION FOR CONTINUATION Fax 503.415.2304 418-18 FNp�J1� \\\ W 14,5 LV—fi r BT-t a` WC-1 '` 4) 2& yes" � 1 t t. TO 2" V F EXPIRES: 30JUN18 '`Q�RTy 1 1/2" w `.o�RTh F�oO F� O 3" W FOO STAMP 1 1/2" W LV-1 BT-1 we-1 M Consulting Engineers 2007 S.E. Ash St. 2 V Ty/ O 2" V F I Portland, OR 97214 R \\\Ty�QO " Ty�RO PHN: (503) 234-0548 FAX: (503) 234-0677 2" W F<0, 2" W ��0 3 W ODOR INC.WWW.MFIA-ENG.COM CONTACT: Bryan Gregory 77 CONSULTANT BT-1 a, we-1 ,— v 2 wQQyp F�0 2" wQQ�p F(Q 2" v ., 3wQQyp F(Q pR 3" W 9R QR LV-13, W WC-1 LV-1 98 P� 9e NOTE: DRAINAGE CONNECTIONS SHALL NOT BE MADE INTO A DRAINAGE PIPING SYSTEM WITHIN 8 FT OF ANY VERTICAL TO HORIZONTAL CHANGE OF DIRECTION OF A STACK CONTAINING A SUDS- PRODUCING FIXTURE. EXCEPTION: STACKS RECEIVING THE DISCHARGE FROM LESS THEN 3 STORIES OF PLUMBING FIXTURES. 1 RISER " 11 " TYPICAL ( DFU `7 2 RISER " 12" TYPICAL ( DFU 6 ) 3 RISER " 13" TYPICAL ( DFU 10) 5 0 NO SCALE 5 O NO SCALE 5 O NO SCALE N Z cW G I.L � m (/J 0 J i Q a Q /'1 z W Q o' (n N J U) C14 W 11 C" Li Y o z N m W ry 2E �— cn h- a_ TITLE 2 DATE DESCRIPTION REVISIONS BKG JILT DRAWN BY CHECK BY PERMIT SET STATUS 04.18.18 DATE 17052 PROJECT NUMBER P5002 ©2017 OTAK,INC. LL If this drawing is not 24"x 36", it has been w reducedlenlarged. Scale accordingly. X Otak �� ► Otak Architects, Inc 808 SW 3rd Ave, Suite 300 Portland, OR 97204 Phone 503.287.6825 Fax 503.415.2304 4-18-18 VENT FLASHINGDP "0���r� ROOF `v 14,5 r ✓L4r 26, 1 909 1 4" DOMESTIC TO FIXTURES C. TORM�` VENT FITTING BELOW EXPIRES: 30JUN18 4" CW TO BLDG COUNTERTOP SHALL BE TO VENT STACK LONG RADIUS STYLE STAMP PRESSURESINK KEEP AS HIGH AS POSSIBLE TOP OF COUNTER GAUGE PRESS. GAUGE WALL INTERIOR WALL M Consulting Engineers 007 S.E. Ash St. 3" DWV PLUMBING PIPE ortland, OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 A" 3/4" RISER DRAIN WITH " INC.WWW.MFtA-ENG.COM HOSE CONNECTION. 1 1/2 VENT CONTACT: Bryan Gregory 3" BY-PASS �� CONCRETE SLAB CONSULTANT RISER AS SIZED PRESSURE REDUCING BALL VALVE ON ON PLAN. � VALVE � � 1/2" CW & HW UNION BALL VALVE N.C. TEE BUILDING SHUT OFF PRESSURE REDUCING VALVES WITH INTEGRAL STAINLESS STEEL STRAINERS. SET LARGER 100 GPM CLEAN-OUT-�� MIN 6 MIL. POLYETHYLENE PRV AT 106 PSI TO 65 PSI. AND FLOOR CONTINUOUS MEMBRANE SMALLER 80 GPM PRV AT 106 PSI -- AGGREGATE BASE TO 75 PSI. 3" PLUMBING TEE 4" CW MAIN WASTE LINE NOTE: PROVIDE ONE VENT PER 2000 SF OF CONTINUOUS BUILDING SUB-SLAB AREA. 1 DOMESTIC WATER RISER 1 a DOUBLE PRV PIPING DETAIL 2 PENINSULA FIXTURE 3 RADON VENTING P6.01 NOT TO SCALE P6 01 NOT TO SCALE P6.01 NO SCALE P6.01 NOT TO SCALE COLD WATER MANIFOLD MOUNTED IN STRUCTURE EXPANSION ABOVE CEILING TANK BRANCH LINES Z TO FIXTURES UNIT SHUTOFF W FLANGE ANCHORED RAIN DRAIN VALVE G TO WALL `r \_ HOT WATER MANIFOLD COLD WATER LINE , MOUNTED IN STRUCTURE a FROM ABOVE SEE PLAN � ABOVE CEILING Q J 0 o C/311 PRESS.-TEMP. Q J RELIEF VALVE ♦^ 0 Q OVERFLOW SPOUT V♦ z (12" ABOVE GROUND)\ 2" DISCHARGE FLOOR SLAB Q Cco 14 GATE VALVE CONNECT TO 4" W WALL U) CHECK VALVE I W W J Y0 Z SEISMIC STRAP r WATER HEATER DRAIN PAN j SP-1 3/4" DRAIN TO �� AS UNT REQUIREDNTO"PERMITTALLPDRAINRPAN i o ELEVATOR PIT GROUND LINE EXTERIOR DRAINAGE TO EXTERIOR. ELEVATOR SUMP PUMP U) SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION TITLE 4 ELEVATOR SUMP PUMP 5 OVERFLOW MOUNTING DETAIL 6 UNIT WATER HEATER # DATE DESCRIPTION !6.01 NO SCALE P6 01 NOT TO SCALE P6 01 NOT TO SCALE REVISIONS BKG JILT DRAWN BY CHECK BY PERMIT SET STATUS 04.18.18 DATE 17052 PROJECT NUMBER P6001 ©2017 OTAK, INC. LL If this drawing is not 24"x 36",it has been reduced/enlarged. Scale accordingly.