Plans (76) M EC2018 -00296 Otak MECHANICAL LEGEND EXHAUST FANS FURNACE & CONDENSING UNITR /„ MARK EF EF FURNACE NUMBER MARK NUMBER � e RECEIVED •••••••••••••••••••SUPPLY AIR DIFFUSER AFF •••••••••••••••••••• ABOVE FINISH FLOOR Otak Architects, Inc ® AHU .•.....-•••••...•• AIR HANDLING UNIT TYPE APR 2 3 2018 ® CEILING CEILING SYSTEM COMMUNITY LEASING 808 SW 3rd Ave, Suite 300 ••••••RETURN AIR GRILLE B.D. ••••• BOTTOM OF DUCT DIRECT DRIVE DIRECT DRIVEnpE CONDENSING CONDENSING CITY Ur i IUARD Portland, OR 97204 BHP .......••..-••-... BRAKE HORSEPOWER SUIL71NIr-i DIVISION Phone 503.287.6825 ® ••••••••••••••••••••EXHAUST AIR GRILLE BTU ......•••••...••... BRITISH THERMAL UNITS SYSTEM BATHROOM JANITOR CONFIGURATION VERTICAL VERTICAL CFM ..................•• CUBIC FEET PER MINUTE Fax 503.415.2304 ....................PERFORATED RETURN AIR PANEL CONN. ..................•• CONNECTION CFM 30 80 30 TOTAL CFM 1990 1950 CONT. ......••••••....•... CONTINUATION TOTAL SP. (IN H20) 0.25 0.25 o ECONOMIZER YES YES 4-18-18 / / OR ....••••••DIRECTIONAL AIR FLOW CW .................... DOMESTIC COLD WATER RPM 1062/1131 1062 b �DPROFF DB ..................•• DRY BULB MIN. OSA (CFM) 300 150 �S�E I N4 fJ w ••••••••••••••••••••MANUAL VOLUME DAMPER DIA. ......••••••..•... . DIAMETER TIP SPEED (FPM) -- -- OFFICE COPY v DIST. ••••..............•• DISTRIBUTION z¢ EXTERNAL SP. (-H20) 0.5" H2O 0.5" H2O w 14,5 SUPPLY OR OUTSIDE AIR ......•••„•,,... MOTOR WATTS 5/11 .7 5 CM OF TIGARD '� ..................DUCT UP Se DOWN EA . EXHAUST AIR DISCHARGE DIRECTION VERTICAL VERTICAL EDB ..................•. ENTERING DRY BULB TEMPERATURE CONTROLLED BY * REVI D FOR CODE COAIPLIANCE 4)'26. j9e� RETURN AIR DUCT UP & DOWN EWB Approved: ENTERING WET BULB TEMPERATURE CONTINUOUS 10 [A© EWT ............•••..•. ENTERING WATER TEMPERATURE INTERLOCK WITH MOTION -- MIN FILTER SIZE (SQ. FT) 3.5 3.5 OTC: TORM 13111-11 ••••••••••••••••••••EXHAUST AIR DUCT UP & DOWN FF ..................•. FINISH FLOOR FAN SPEED CONTROLLER YES YESEXPIRES: 3oJUN18 FPM •••••••••••••••••••. FEET PER MINUTE co GAS INPUT (MBH) 80/52 80/52 Permit #: ►np_ An I.3R _ SUPPLY OR OUTSIDE AIR FPS ............••••-•. FEET PER SECOND WHEEL TYPE BI BI GAS OUTPUT (MBH) 78/51 78/51 Address: -x-41"190 � � ,""'-� �Q2......••••••.......• FT. ..................•• FEET / FOOT DAMPER BACKDRAFT BACKDRAFT Suite -�)s ro STAMP DUCT UP & DOWN GPM ......•••.•••••...•• GALLONS PER MINUTE = STAGES 2 2 12 )d�_ RETURN AIR DUCT UP & DOWN HP """""'•"""•' HORSEPOWER ISOLATION RUBBER RUBBER AFUE % 96 96 By: =Lt Date: g G) LD. ...•..........••••.. INSIDE DIAMETER DESIGN WEIGHT (LBS) 25 25 M Consulting Engineers ................... �c ••••••••••••••••••••EXHAUST AIR DUCT UP & DOWN IN. � INCHES MAX. SONES 0.3/0.6 0.3 LBS. ................... POUNDS CONDENSING UNIT CU CU T T 2007 S.E. Ash St. LOB ..................•• LEAVING DRY BULB BASIS OF DESIGN PANASONIC PANASONIC MARK NUMBER r 1 Portland, OR 97214 LWB •••••••••••••••••••� LEAVING WET BULB LWT ......•••.••••..•..• LEAVING WATER TEMPERATURE FV-05-11VKS1 FV-05-11VKS1 /� PHN: (503) 234-0548 OAC-4 •••••••••••••••••••THERMOSTAT OR TEMP. SENSOR MAX. ..................•. MAXIMUM * SENSIBLE (MBH) 57 57 1"-1 FAX: (503) 234-0677 - FAN TO RUN AT LOW SPEED CONTINUOUSLY, AND INCREASE MBH ............•....... THOUSANDS OF BTUs PER HOUR TO HIGH SPEED UPON ACTIVATION OF THE MOTION SENSOR. z TOTAL (TONS) INTACT: Bryan Gregory 0 NOTE MIN. MINIMUM ** - FANS TO INCLUDE MOTION SENSOR AND MULTI SPEED o 5.0 5.0 CONTACT: Bryan Gregory o ENT. AIR (DB/WB.) 80/67 80/67 VALIDITY OF PERMIT' CONSULTANT NC ..................•• NOISE CRITERIA CONTROL WITH TIME DELAY. AMBIENT AIR ('F) 95 95 THE ISSUANCE OF A PERMIT N.C. •••••••••�-••�-�.. NORMALLY CLOSED XX ••••••••••••••••••••EQUIPMENT DESIGNATOR N.I.M. ..................•• NOT IN MECHANICAL BASED ON CONSTRUCTION NO. ............•.••.... NUMBER EFFICIENCY (SEER) 13 13 DOCUMENTS AND OTHER N.O. ..................•• NORMALLY OPEN DATA SHALL NOT PREVENT I� ••••••••••••••••••••BALL VALVE O.A. .................... OUTSIDE AIR THE CODE OFFICIAL FROM T4 ••••••••••••••••••••GATE VALVE PSI .................... POUNDS PER SQUARE INCH EH ELECTRIC WALL MOUNTED HEATER WITH FURNACE DESIGN WEIGHT (LBS.) 200 200 REQUIRING THE CORRECTION P/T """'•"•"'••"" PRESSURE / TEMPERATURE INTEGRAL THERMOSTAT, 1.5 KW 0 120V BASIS OF DESIGN (MANUF/ MODEL) CARRIER 59TP6 CARRIER 59TP6 OF ERRORS. OSSC 105.4 �i •••••••••.•.•.•....•CHECK VALVE R.A. '••• ....•"""... RETURN AIR REQ'D """"..... REQUIRED CONDENSING UNIT DESIGN WEIGHT (LBS.) 1 200 200 O p ....................BALANCING VALVE S.A. .""""..... SUPPLY AIR S.P. """"""""" . STATIC PRESSURE BASIS OF DESIGN (MANUF/ MODEL) CARRIER 24 ACB CARRIER 24 ACB THERMOMETER SQ. """""""""'• SQUARE NOTE: PROVIDE CONDENSATE NEUTRALIZATION KIT ON DRAIN TEMP. """""""""" TEMPERATURE TYP. ..............'..... TYPICAL +- ....................DIRECTION OF FLOW W .................... WIDTH WB -................. WET BULB ••••••••••••••••••••PUMP WPD """"""'.""". WATER PRESSURE DROP 0 .................... DIAMETER 1p�y ••••••••••••••••••••STRAINER ............•••-•.. VENTILATION AIR SCHEDULE - Bldg 3 ....................PRESSURE GAUGE NEW WORK {TAFP ....................DOUBLE CHECK ASSEMBLY ROOM NUMBER AREA (SQ. FT.) OCCUPANT NUMBER OF OUTSIDE AIR OUTSIDE AIR OUTSIDE AIR ZONE SUPPLY PRIMARY RETURN EXHAUST Zone Corrected AIR C� ............'•""•.PRESSURE REDUCING VALVE CD CONDENSATE DRAIN AND NAME LOAD OCCUPANTS REQUIREMENT REQUIREMENT REQUIRED (CFM) OSA AIR(CFM) OSA AIR (CFM) AIR (CFM) Ventilation OSA SYSTEMS I I """"""""""UNION 1--NAT-y NATURAL GAS (#/1000 SQ. FT.) (CFM/P) (CFM/SQ FT.) (CFM) FRACTION Efficiency CFM O ....................CAP . ..................FIRE DAMPER Az Pz Rp Ra Vbz Ez Voz Vpz Zp Evz � O SMOKE DETECTOR COMMUNITY 1395 30 42 5 0.06 294 1.0 294 1900 0.15 1900 0 1.00 293.70 F-1 W O ......••••• •••••••FIRE / SMOKE DAMPER LU MOTORIZED DAMPER TOTAL 1395 42 294 294 1900 1900 0 1.00 294 J 777 ® SMOKE DAMPER Vou VPs Ev CORRECTED TOTAL OUTDOOR AIR FLOW RATE 294 CFM Corrected OSA Fractioi Zs= 0.15 W W OFFICE 101 5 1 5 0.06 11 1.0 11 75 0.15 75 0 0.93 11.89 F-2 AIR DISTRIBUTION DETAILS LEASING 392 10 4 5 0.06 44 1.0 44 530 0.08 530 0 1.00 46.80 F-2 H (n CORRIDOR 128 0 0 0 0.06 8 1.0 8 400 0.02 400 0 1.06 8.26 F-2 J BOTTOM DUCT -T FITNESS 293 10 3 20 0.06 78 1.0 78 800 0.10 800 0 0.98 83.42 F-2 F- ------- _______ 15' MAX. 15' MAX. TOTAL 914 8 140 140 1805 1805 0 0.93 150 ^a J U a Vou Vps Ev LL Q Z TURNING VANES IN ALL LINED DUCTWORK TOP DUC SQUARE ELLS AND TEES RECT. TO RECT. RECT. TO ROUND - Q � Q DUCT CROSSINSPECIFICATION REFERENCE TRANSITION CORRECTED TOTAL OUTDOOR AIR FLOW RATE 150 CFM Corrected OSA Fractioi Zs= 0.08 G - - _ S ♦^ Z U SA = SUPPLY DIFFUSER V/ RA = MATCHED RETURN Q cy) W EXH = EXH GRILLE N 2E W -� 8"- SA ARROWS INDICATE ~ W o- 0' 15'<A590' AS 15' `Y' 200 CFM DIRECTION OF AIR FLOW Y SMOOTH RADIUS ELBOW, W/O VANES MITERED ELBOW NECK SIZE R/W = 1 .0 + CEILING DIFFUSER/GRILLE N O Z ELBOWS BALANCED AIRFLOW, C M. SIDEWALL DIFFUSER/GRILLE FLEX DUCT - MAX 48" W � 0 0 BRANCH DUCT = = Q J ROUND OR RECTANGULAR MAIN WALL SPIN-IN FITTING WHERE U ::::� ROUND SA/RA DUCT APPLICABLE. GENFLEX U) H m 6" TRANSITION FROM SM-1DEL (WITH DAMPER TITLE 1" MAIN TO ROUND AND 45' EXTRACTOR) OR (MIN. CROSS-SECTIONAL APPROVED EQUAL. AREA TO MATCH ROUND). # DATE DESCRIPTION ROUND DUCT W/ CONICAL FITTINMANUAL VOLUME MANUAL VOLUME DAMPER DAMPER ROUND DUCT TRANSITON W/ ROUND DUCT TEE SPIN-IN FITTING OFF TOP OF AIR TERMINALS MAIN DUCT RECTANGULAR MAIN REVISIONS THE ACTIVATION OF A DUCT BKG JILT SMOKE DETECTOR SHALL DRAWN BY CHECKBY ACTIVATE A VISIBLE AND PERMIT SET AUDIBLE SUPERVISORY STATUS SIGNAL AT A CONSTANTLY ATTENDED LOCATION 04.18.18 GMSC 606.4.1 DATE 17052 PROJECT NUMBER M0201 ©2017 OTAK, INC. ii If this drawing is not 24"x 36'•it has been reduced/enlarged. Scale accordingly. Otak �amo#A*OK ► Otak Architects, Inc 808 SW 3rd Ave, Suite 300 Portland, OR 97204 Phone 503.287.6825 Fax 503.415.2304 4-18-18 GENERAL NOTES KEY NOTES �� DP" �rr4 1. WORK SHALL COMPLY WITH CURRENT O1 PROVIDE WALL CAP WITH BACKDRAFT DAMPER w 14,5 OREGON SPECIALTY CODE. AT EXHAUST DUCT TERMINATIONS. PROVIDE BUG SCREEN ON BATHROOM EXHAUST FAN 2. COORDINATE INSTALLATION WITH OTHER OUTLETS. MAINTAIN 3' CLEARANCE TO y ✓�cr su �geg TRADES. OPERABLE WINDOWS AND DOORS. c^S F t. T OR- 3. ALL DUCTWORK SHALL BE RIGID SHEET O2 COORDINATE GAS METER LOCATION WITH NWNG I EXPIRES: 30JUN18 METAL INSULATED PER CODE. PROVIDE CO. 4" RESTROOM EXHAUST. O ROUTE GAS LINE DN IN WALL TO PRE STAMP 4. MOUNT THERMOSTATS AT 46" TO TOP OF SLEEVED LINE BELOW GRADE AND OUT TO OPERABLE CONTROL. FIRE PIT (80 MBH). 5. PROVIDE BALANCING DAMPERS ON SUPPLY ® PROVIDE GAS WITH SHUT OFF VALVE FOR AND RETURN OUTLETS. POOL HEATER (400MBH). M Consulting Engineers 2007 S.E. Ash St. 6. PIPE MECHANICAL EQUIPMENT CONDENSATE O PROVIDE 36X26 INTAKE LOUVER I Portland, OR 97214 TO APPROVED PLUMBING RECEPTOR. 1 PHN: (503) 234-0548 © PROVIDE 18X18 UP TO RELIEF HEAD FAX: (503) 234-0677 7. ANGLE SPIRAL DUCT MOUNTED DIFFUSERS INC.WWW.MFIA-ENG.COM DOWN AT 22.5'. O ROUTE FURNACE INTAKE AND VENT UP TO CONTACT: Bryan Gregory CONCENTRIC ROOF VENT CONSULTANT 3. 1 3.2 3.3 3.4 I I I ( I Cu W i 5 7. GECH F PUL AGUIP 3 FITNESS 1 TORE I 3 110 ' 1" NAT - 3-106 I - s 24X6 SA I - 400 CFM 6.0 1 X16 RA (TYP• OF 2) A 41T 11 6.0 Z 8 0 CFM EF EF I EF 1 2 a 1 1 W Z 3'B T , o RE TROOM RESTROO 0- 18X1 8 Z18X18 RAI N -112 3-111 J 2000 CFM i 1 I.L LUNITY I U U —j � 3-105 1 -j— iCL J z a 10"0 SA I 110"0 SA 1 j 12X6 SA ��//�� 0 (TYP CFM I v� z Cw I-- N G - - - - - - - - I I I I J 0) M LU INT NCE I I Z p 0 ,3- 0 1 I I = = Q =' co AL 6SA 7 TITLE 18x18 SA 0 X6 122X6 SA I I # DATE DESCRIPTION 5 OFF 200 CFI EFMRA- - - - - - - - - - - - - - - - - - - - T U) 8X18 RA N 930 CFM 14X6 SA 101 265 CFM) TYP O 2 I I REVISIONS 3. F - - - -- - - - - - - - - - - 1 - - - - - - - BKG JILT 2 PSI GAS METER I I I DRAWN BY CHECK BY 700 MBH AT 175 FT i 1 PERMIT SET 2 STATUS 04.18.18 DATE 17052 1 FIRST FLOOR MECHANICAL PLAN PROJECT NUMBER 3-2.� SCALE: 1/8" = 1'-0 M3=2001_ ©2017 OTAK, INC. _d 11 this drawing is not 24"x 36",it has been reduced/enlarged. Scale accordingly. rr Otak �Am##A*O' ► INSULATED OSA (WITHIN BUILDING Otak Architects, Inc ECONOMIZER RELIEF TO ENVELOPE) TO OSA PLENUM; SEE 808 SW 3rd Ave, Suite 300 ROOF; SEE PLANS FOR PLANS FOR CONTINUATION Portland, OR 97204 CONTINUATION Phone 503.287.6825 Fax 503.415.2304 ECONOMIZER a-ts->a CONCENTRIC COMBINATION 14,5 GAS VENT AND r COMBUSTION AIR, LINE FIRST 10 < 909 YY61 ' FEET OF SA DUCT TpRM`` i I EXPIRES: 30JUN18 RETURN AIR i I DX FLASHING EVAPORATOR STAMP �UCT EE LOORSPLANS I ; COIL ROUTE TO GAS VENT ROOF FOR CONTINUATION i �COMBUSTIO� CONC NE IC ROOF CENTRIFUGAL IN-LINE EXHAUST FAN CONCENTRIC M g Engineers C007 Sin St. AIR VENT; 2007 S.E. Ash St. HANG FAN FROM STRUCTURE ABOVE i F I Portland, OR 97214 WITH MOUNTING BRACKETS, TYP. VIBRATION ISOLATOR, TYPICAL i COOLING COIL PHN: (503) 234-0548 ALL MOUNTING LOCATIONS irl CONDENSATE FAX: (503) 234-0677 DRAIN INC.WWW.MFIA-ENG.COM CONTACT: Bryan Gregory SHUT OFF GAS VALVE ( I ( I I CONSULTANT FA�FURNACE MANUFACTURER APPROVED UNION `---- SECTION CONDENSATE WALL EXHAUST CAP. ; DRAIN WITH WITH INTEGRAL BACKDRAFTI -- DAMPER. COORDINATE WITH 6 DIRT LEG CONDENSATE EXTERIOR SIDING. i NEUTRALIZATION LINE FIRST 10 FEET OF RA ----------- ---- - EXTERIOR WALL ACCESSIBLE FILTER CEILING HOUSING AND FILTER 3" PVC GAS VENT FLOOR TRANSITION DUCT TO FAN CONNECTION SIZE 3" COMBUSTION AIR VENT EXHAUST DUCT SIZE SHOWN ON PLANS 1 RESTROOM EXHAUST FAN 2 TYPICAL FURNACE DETAL 3 CONCENTRIC GAS VENT M6,01 NOT TO SCALE M6,01 NOT TO SCALE M6,01 DETAIL W Z J W o H J Q _j 0 Q o 2 U) z U a ``' w C U- 04 G J � � M W Y O LJ. N O z W 7) w I— m TITLE # DATE DESCRIPTION REVISIONS BKG JILT DRAWN BY CHECK BY PERMIT SET STATUS 04.18.18 DATE 17052 PROJECT NUMBER M6001 ©2017 OTAK. INC. d If this dewing is not 24"x 36",it has been -� reduced/enlarged. Scale accordingly.