Loading...
Plans (69) FPS2021 -00022 STIPULATION FOR USE: THIS DRAWING WAS PREPARED FOR THE USE ON RECEIVED THIS SPECIFIC PROJECT CONTEMPORANEOUSLY WITH ITS ISSUE DATE AND IT IS NOT SUITABLE FOR FEB i 7 2021 USE ON A DIFFERENT PROJECT SITE OR LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR CITY OF TIGARD EXAMPLE ON ANOTHER PROJECT REQUIRES THE BUILDING DIVISIOI, SERVICES OF BASIC FIRE PROTECTION, INC. REPRODUCTION OF THIS DRAWING FOR REUSE ON 1 ANOTHER PROJECT IS NOT AUTHORIZED AND MAY 1 BE CONTRARY TO LAW. al 14 ® 9 a ;Bf LEGEND Q Hydraulic Reference Point q® Main Designation HI I I Center Line 1 O O O Q Line Designation —� Hanger D Cap —� Plug • Drop 0 0 00 Rise ® Double Check Assy. (9 ® —t>T� OS&Y Gate Valve (S&Y) 0ft 4 Flow Switch (FS) 1 rf�i Electric Bell Strobe AREA OF WORK -0— Check Valve s ® System Riser 1 c�s Fire Dept. Conn. (Standard) �� Fire Dept. Conn. (Flush) D D Double Detector Check Assy. pry) C�p Fire Dept. Conn. (Sidewalk) 2J' Post Indicator Valve (PIV) ✓ 6eoou l .8. Fire Hydrant (3 Way) a pV Thrust Block 7T1 law, 1-7 E Co 1 rRFxog Fire Hose Assembly 0 Grooved Coupling Flanged Connection a Globe Valve ■ 01 Angle Valve Reduced Pressure Assy. 47 --1�Al x1 2 Way Earthquake Brace 1 a ® a + 4 Way Earthquake Brace NJ I FS REVISIONS NO. DATE BY COMMENTS 1 2/17/2021 UP PERMIT PLAN 1 I arm a 1 O 38� ® a a wa a s a 9 1 I! 1 a APPROVALS REQUIRED r CITY OF TIGARD 1 a M a a I 1 ° • % 4 GENERAL NOTE: ° IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE A OWNER'S RESPONSIBIUTY TO PROVIDE HEAT THROUGHOUT AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM AND IN se' x 3' KWIK BOLT TZ ENCLOSURES FOR DRY PIPE DELUGE AND OTHER TYPES OF FIRE SPRINKLER PLAN SUITE 150 SPRINKLER VALVES CNKLER SYSTEMS.WATER SUPPLIES TO FP1.10 SCALE: 1/8" = 1'-0" NORTH 2' MIN. EMBEDMENT SPRINKLER SYSTEMS. / " •s' ROD COUPLING CONTRACT WITH: 38' ALL THREAD ROD SCOPE OF WORK RUSSELL CONST. 20915 SW 105TH AVE • MODIFY EXISTING FIRE SPRINKLERS FOR NEW _.ADJUSTABLE RING HANGER TUALATIN, OR 97062 FLOOR AND CEILING LAYOUT PER DRAWING. CONTACT: CARMEN CRUZ • SPRINKLER SPACING PER 2016 NFPA 13 FOR TEL NO.: 503-692-9002 LIGHT HAZARD OCCUPANCY. E-MAIL: CCRUZ®RUSSELLCONSTRUCTION.COM KWIK BOLT TZ HANGER JOB SITE SUPERVISOR: TRAVIS BENEFIEL • FIRE PROTECTION SYSTEM TO COMPLY WITH NFPA 13, 2016 EDITION REQUIREMENTS. JOB SITE TEL NO.: 503-793-5801 AND CITY OF TIGARD REQUIREMENTS. • PER NFPA 13, 25.2.1.4: MODIFICATIONS AFFECTING 20 OR FEWER E-MAIL: TBENEFIEL®RUSSELLCONSTRUCTION.0 • FINAL INSPECTION AND APPROVAL BY LOCAL FIRE DEPARTMENT, AND SPRINKLERS SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM QUALITY CONTROL BY: UP ARCHITECT/ ENGINEER. WORKING PRESSURE. APPRVD FOR FAB BY: UP • CUTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS TO BE • PER NFPA 13, 25.2.1.5: WHERE ADDITION OR MODIFICATION IS MADE DONE ONLY WITH APPROVAL OF THE ARCHITECT. TO AN EXISTING SYSTEM AFFECTING MORE THAN 20 SPRINKLERS, ♦ BASIC • PIPE ROUTING SHOWN SHALL BE USED AND ANY ADDITIONAL THE NEW PORTION SHALL BE ISOLATED AND TESTED AT NOT LESS ♦FIRE OFFSETS OR FITTINGS REQUIRED FOR PROPER INSTALLATION, THAN 200 PSI (13.8 BAR) FOR 2 HOURS 16 PROTECTION, INC. COORDINATION WITH OTHER TRADES, AND/OR TO MAINTAIN PROPER • PER NFPA 13, 25.2.1.6: MODIFICATIONS THAT CANNOT BE ISOLATED, Contractor&Designer Of Automatic Fire Sprinklers CLEARANCES SHALL BE PROVIDED. VERIFY EXISTING STRUCTURAL, SUCH AS RELOCATED DROPS, SHALL NOT REQUIRE TESTING IN 8135 NE MLK JR. BLVD. FIRE SPRINKLER T.I. LEGEND MECHANICAL, ELECTRICAL INSTALLATIONS AND AVOID ANY/ALL EXCESS OF SYSTEM PRESSURE PORTLAND, OREGON 97211 OBSTRUCTION OR INTERFERENCE'S WITH FIRE PROTECTION PIPE • DISTANCE FROM SPRINKLER TO HANGER, WHERE MAXIMUM PHONE 503-285-1855 / FAX: 503-285-0713 EXISTING SPRINKLER PIPING ROUTING. PRESSURES EXCEED 100 PSI (6.9 BARS) AND A BRANCHUNE ABOVE WWW.BA .COM NEW SPRINKLER PIPING • FIRE STOP ALL PENETRATIONS OF ALL RATED WALLS, FLOOA CEILING SUPPLIES PENDENT SPRINKLER BELOW THE CEILING SHALL OR.CCB#48641 WA. FSCL#BASICI'235R1 = PROJECT TITLE: ROOFS (FLASH AND COUNTER FLASH ROOF PENETRATIONS), ECT. NOT EXCEED 12' FOR STEEL PIPE AND 6' FOR COPPER PIPE. xQ A = SPRINKLER TO ADD (SEE FIRE RATED PIPE PENETRATIONS DETAILS) • THE HANGER CLOSEST TO THE SPRINKLER SHALL BE OF A TYPE UD 5 LINCOLN "'1 7pr = • ACCESS PANELS TO BE PROVIDED BY THE GENERAL CONTRACTOR THAT PREVENTS UPWARD MOVEMENT OF PIPING. �( EXISTING UPRIGHT SPRINKLER SUITE 15 0 o - FOR ALL VALVES ABOVE NON-ACCESSIBLE CEILINGS AND CHASES. • PER NFPA 13, SMALL ROOM: A ROOM OF LIGHT HAZARD OCCUPANCY m EXISTING PENDENT SPRINKLER • SPRINKLER HEADS ARE TO BE COORDINATED WITH ALL DIFFUSERS CLASSIFICATION HAVING UNOBSTRUCTED CONSTRUCTION AND FLOOR 10200 SW GREENBURG RD (1) TENANT IMPROVEMENT RELOCATE SPEAKERS, LIGHTING FIXTURES AND CEILING SYSTEMS. AREA NOT EXCEEDING 800 SQ. FT. THAT ARE ENCLOSED BY WALL 0 o-• R TIGARD, OR 9 N • METHODS OF HANGING PIPES, HEADERS AND BRANCHES SHALL BE IN AND CEILING. OPENINGS TO THE ADJOINING SPACE ARE PERMITTED P = PLUGGED SPRINKLER FIRE SPRINKLER T.I. ACCORDANCE WITH NFPA 13. IF THE MINIMUM LINTEL DEPTH IS 8' FROM CEILING, PER NFPA 13; N 4 2 0 2 4 8 12 16 X'-X" = CEILING ELEVATION - MAINTAIN A MINIMUM OF 18 INCHES FROM THE BOTTOM OF THE AS DEFINED AS 'SMALL ROOM' SPRINKLERS SHALL BE PERMITTED TO SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL X_X = PIPE ELEVATION SPRINKLER DEFLECTOR TO THE TOP OF STORAGE / FILE STORAGE. BE LOCATED NOT MORE THAN 9'-0' FROM ANY SINGLE WALL AND UP 2/17/2021 CL SCALE: 1 /8 = 1 '-0" - ISSP CONC. WHT 165' 5.6 1/2- 2115 IRASCO G4 PROVIDE SYSTEM(S) WITH PROPER FLUSHING CONNECTIONS PER NFPA SPRINKLER AREA LIMITATIONS SHALL NOT BE EXCEEDED. FP,�O JOB N33MBER LL