Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (27)
BUP2020 -00238 MILDREN RECEIVED GROUP Ar ❑ ❑ Au ❑ er =� P ❑ AUG 2 4 2020 V ROUP CBou O � � Boo ARCHITECTURE I INTERIORS BUILDING D IVISION 4875 SW Griffith Drive,Suite 300 Beaverton,Oregon 97005 O 1 503.244.0552 7 : 75 SW Hunzker Sg T o ar d9 OR 97223 GENERAL NOTES BUILDING SUMMARY DRAWING INDEX-ARCHITECTURAL CODE INFORMATION BASED ON OREGON STRU18 CTUNAL RING ADE AND L PLUMBING COUNT AO — COVER SHEET 1. MAINTAIN 100 ANDSPECIALTYCODEAMENDMENTS COVERAGE FROM EXISTING FIRE SPRINKLER AND SMOKE & FIRE ALARM SYSTEM PER FMO. Al — FLOOR/FIRE LIFE SAFETY PLAN 2. EXIT SIGN, EMERGENCY ILLUMINATION, SPRINKLERS, SMOKE DETECTION, FIRE DETECTORS, FIRE ALARM COMMUNICATION A2 — DETAILS DEVICES AND ALL OTHER REQUIREMENTS TO CONFORM TO ALL PERTINENT BUILDING, FIRE AND LIFE SAFETY CODES. REQUIRED A3 — SITE PLAN 3. FIRE EXTINGUISHERS FINAL LOCATIONS TO BE APPROVED BY THE FIRE MARSHAL. FIRE EXTINGUISHERS TO BE CONSTRUCTION TYPE: III—B B: 29/2 = 14 PER SEX LOCATED IN ACCESSIBLE LOCATIONS, IN PLAIN VIEW WITH A MAXIMUM PATH OF TRAVEL OF 75 FEET AND MAXIMUM FLOOR AREA AS FOLLOWS: BUILDING HEIGHT: 1 STORY 14/25 = 56 • LIGHT HAZARD OCCUPANCY — 1 PER 3,000 S.F. BUILDING OCCUPANCY: B/S1 14/40 = .35 • ORDINARY HAZARD OCCUPANCY — 1 PER 1,500 S.F. • EXTRA HAZARD OCCUPANCY — 1 PER 1,000 S.F. BUILDING TOTAL SQUARE FOOTAGE: 84,000 SF S1: 73/2 = 37 PER SEX 4. PROVIDE A SIGN READING "THIS DOOR SHALL REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" AS DESIGNATED OR TENANT IMPROVEMENT SQUARE FOOTAGE: 37/100 = .37 REQUIRED BY CODE OR BUILDING OFFICIALS. S7: 19,885 SF 5. PENETRATING ITEMS PASSING ENTIRELY THROUGH BOTH PROTECTIVE MEMBRANES OF BEARING WALLS ARE REQUIRED B 1066 SF .56 + .37 = .93 WC PER SEX : , TO HAVE A FIRE—RESISTIVE RATING. WALLS REQUIRING PROTECTED OPENINGS SHOULD BE PROTECTED WITH THROUGH .35 + .37 = .72 LAV PER SEX 1 WC PER SEX � D PENETRATION FIRE STOPS PER BUILDING AND FIRE CODE. OCCUPANT LOAD FOR TENANT IMPROVEMENT: / 1 LAV PER SEX S1: 73 PERSONS CONTRACTOR INFORMATION B: 28 PERSONS EXISTING �C'J ARI-12079 r� 1. CONTRACTOR SHALL MAKE EVERY EFFORT TO HAVE A FULL UNDERSTANDING OF SPECIFIC POLICIES OF PROPERTY TOTAL: 110 PERSONS �1 MANAGEMENT FOR COMPLETING WORK AT THE PROPERTY. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH ALL 1 WC — MEN / 1 LAV — MEN Z'1 APPLICABLE CODES, LAWS, RULES AND REGULATIONS HAVING JURISDICTION. CONTRACTOR RESPONSIBLE FOR FIRE PROTECTION: BUILDING EQUIPPED WITH AN AUTOMATIC FIRE 1 WC — WOMEN / 1 LAV — WOMEN 5 INSPECTIONS OF WORK. CONTRACTOR SHALL OBTAIN A PERMANENT CERTIFICATE OF OCCUPANCY PRIOR TO TENANT PROTECTION SYSTEM IN ACCORDANCE WITH 1 WC — UNISEX / 1 LAV — UNISEX • MOVE IN. O.S.S.C. 903.3.1.1 TIGARD, 2. CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION, CONFLICTS SHOULD BE TOTAL: 3 WC / 3 LAV OREC,ON BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE CONSTRUCTION. DO NOT SCALE DRAWINGS, REQUEST OF (� DIMENSIONS FROM ARCHITECT. PP v> 3. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES AND ORDINANCES. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ADEQUATE PRECAUTIONS TO PROTECT BUILDING OCCUPANTS, MATERIALS, AND EXISTING FINISHES THROUGHOUT ALL PHASES OF CONSTRUCTION. NOISE, SECURITY AND DUST BARRIERS BETWEEN CONSTRUCTION AREAS AND OCCUPIED OR PUBLIC AREAS SHALL BE MAINTAINED BY CONTRACTOR. BARRIER REMOVAL IMPROVEMENT TEMPORARY STRUCTURES WHICH REQUIRE TEMPORARY ENCLOSURES (E.G. DUST BARRIERS) TO BE CONSTRUCTED KEY PLAN SITE PLAN USING NONCOMBUSTIBLE, FLAME—RESISTANT, ETC. MATERIALS. THE USE OF POLYPROPYLENE PLASTIC OR SIMILAR COMBUSTIBLE MATERIALS (PLYWOOD, ETC.) TO ENCLOSE DEMOLITION WORK IS NOT PERMITTED BY THIS SECTION. PLAN(PER 2017 oRs 447241) 5. THE CONTRACTOR SHALL WARRANTEE ALL PARTS, LABOR, EQUIPMENT, AND MATERIALS PROVIDED UNDER THIS CONTRACT FOR A PERIOD OF ONE (1) YEAR UPON COMPLETION OF CONTRACT. \ 6. CONTRACTOR INITIATED CHANGES AND SUBSTITUTIONS TO BE SUBMITTED IN WRITTING FOR APPROVAL TO ARCHITECT I IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE UNDER THIS FOR APPROVAL PRIOR TO PROCUREMENT, FABRICATION OR CONSTRUCTION. CHANGES ON SHOP DRAWINGS DO NOT SECTION, PRIORITY SHALL BE GIVEN TO THOSE ELEMENTS THAT WILL SATISFY THIS REQUIREMENT. B OCC PROVIDE THE GREATEST ACCESS. ELEMENTS SHALL BE PROVIDED IN THE 7. ALL DELEGATED DESIGN ITEMS TO BE SUBMITTED TO AND APPROVED BY THE ARCHITECT PRIOR TO SUBMITTING FOR FOLLOWING ORDER: PERMIT. 8. PROVIDE SHOP DRAWINGS AND SUBMITTALS FOR THE FOLLOWING: 1. PARKING: LIGHTING PROJECT SITE —New Accessible Parking Stall Tenant FIRE/LIFE SAFETY DEVICES LOCATIONS 2. ACCESSIBLE ENTRANCE 9. ALL MATERIALS AND EQUIPMENT TO BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN PROJECT SITE —New Accessible Ramp INSTRUCTION AND TRADE ASSOCIATED ACCEPTED STANDARDS. A W 3. ACCESSIBLE ROUTE TO THE ALTERED AREA Artistic 10.ALL WORK LISTED, SHOWN, OR IMPLIED ON ANY CONSTRUCTION DOCUMENTS SHALL BE SUPPLIED AND INSTALLED BY S1 OCC PROJECT SITE COMPLIES THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR SHALL CLOSELY COORDINATE ALL 4. AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A Autobody E V WORK TO ASSURE ALL SCHEDULES ARE MET AND ALL WORK IS DONE IN CONFORMANCE TO MANUFACTURER'S I SINGLE UNISEX RESTROOM — Compliant REQUIREMENTS. I 5. OTHER — 11. UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL THOROUGHLY CLEAN THE PREMISES AND WASH THE ADD HANDRAILS AT EXIT STAIRS Repair Center INSIDE OF ALL WINDOWS SO THE SPACE IS READY FOR OCCUPANCY FOR TENANT. I OFFICE COPY 7875 SW Hunziker St. CITY OF TIGARD /�Area of Work CITY OF TTGARL),, Tigard, OR 97223 approved y Planning ( / REYI D FOR CODL: COMPLIANCE Date: �/ -zo I — — — — — — — APProved: J Initials; I I B occ - I orC: I I I OL:28 ® � S-1 occ - I Pcrmic#: Bu odo ao o o a3 R OL: 73 -- -_- -- 1 _ . All 7 S?7S suite#: ------- :.UTILITY --- Project: --- Bpi Date: ----------- -INDUSTRIAL ----- — CENTER Paint Booths VICINITY MAP I � _ '� - - - ____= DEFERRED SUBMITTALS and Car Wash 5 I - I ' 136'— ' ELECTRICAL VALIDITY OF PERrAIT PLUMBING THE ISSUANCE OF A PERMIT • ---------- I MECHANICAL DOCUMENTS AND OTHER 7875 SW Hunziker St. FIRE LIFE SAFETY / FIRE ALARM BASED ON CONSTRUCTION SPRINKLERS z J DATA SHALL NOT PRFVFNT ACCESSIBLE ALUMINUM RAMP THE CODE OFFICIAL F( OPM Tigard, OR 97223 �'• "s. "_° ' D'•' ' D- REQUIRING THE CORRECT Qid . . OF ERRORS. OSSC 105.4 NOTE: PER OSSC 107.3.4.1 DOCUMENTS FOR DEFERRED SUBMITTAL S1 OCC —6„ ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN " PROFESSIONAL IN REASONABLE CHARGE WHO SHALL REVIEW THEM #, I AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION B OCCINDICATING THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN Ifig REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE ••• '• • �y I DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL Sheet Title: • NOT BE INSTALLED UNTIL THE DEFERRED DOCUMENTS HAVE BEEN Cover Sheet APPROVED BY THE BUILDING OFFICIAL. e �,••� I r � ;` , Cu S1 QCG Site Plan S • D .,• 1„= 100'-0' I�,�, • • PROJECT TEAM ST B OCC Architect MILDREN DESIGN GROUP, P.C. 7650 SW BEVELAND STREET, SUITE 120 TIGARD, OREGON 97223 Key Plan VOICE: 503-244-0552 FAX: 503-244-0417 Revisions: N.T.S. CONTACT PERSON: Sabine O'Halloran iH �Q r D EMAIL: sabine@mdgpc.com General Contractor Building Site ;,, NORTHWEST COLLISION EQUIPMENT VOICE: 1-800-350-8826 CONTACT PERSON: PETE ARBEIA Vicinity Plan N.T.S. RIGHTSNRESERVED DESIGN GOUP, P.C., 2020, All THESE DRAWINGS ARE THE PROPERTY OF MILDREN DESIGN GROUP, P.C.. AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, EXCEPT WITH THE PRIOR WRITTEN PERMISSION OF MILDREN DESIGN GROUP, P.C. Date: 19 August 2020 Drawn by: Checked by: PHB CLT Job Number: 120082 Sheet Building Permit Submittal - August 2020 AO rJF 20'-0" CO. MILDREN DESIGN 14 z----------------- a - - GROUP E C 1 - - ` ° ^ d A4AK (E) WAITI G45. 7 S. 0 104 02 � A \ d° a e I ARCHITECTURE I INTERIORS 67. EXE P T a ad ° ° 4875 SW Griffith Drive,Suite 300 /30 E EN 0 712.67 S.F. 197.08 S. . e d d' < Beaverton,Oregon 67005 S1:E /15 - 8 /15 = 14 ��- ., d � � ^ a d < / ° O 1503.244.0552 10 I I '( d a a.. �� j d a B:EXITS B:EXITS 1 I I I 7 d \ ° d . e< a ad 45.73 S.F. � � ° A d ` EXEw1PT I I I 3 \� ° O 2° 4 /� 3 a ° 4. a 103 FIC E100FFICE I I 1 d a �'`. aQ �/< ° a d 177.26 S.F. 222.2 S.F. I I e a e a e d �� a a d 0 da a /150 = 1 /150 = 2 p e a� d A ° d d B:EXITS 1 B:EXITS 1 I I a ` / A <. A 4 A \ ------------------ ------------------- -------- d' ° ' d. a . . a 4 4 23 41 CD 13 �� ------ --------- ------------------- I °' . SLOPE a<: < ; . ` - - . SLOPE d n 41. AN a A. 16 4 d �\� a q A ° a 16 A / < WAREHOUSE 3 d ` �dj/ d d Q 0- WAREHOUSE O^ I ,08 1 Al I 6 c jQ _ � a d 11663 S.F. -3 6 /300 = 39 a- d >� d _< d 5 a e ° _ d c A ° c 14 S1:EXITS 2 A �\ 14 -------- --------- ---- ---- - ---- I //° d d A2079 `f _ 10 1 i 19 d ~ Oe d d° 4 4 N I 5 O 126 '- 7" EXIT SEPARATION DIST. 16 , Ir, Al 9� OF Enlarged Floor Plan I I I I 16 13 20 -- - ------------ --------------------- ------------------- 16 1 � T- - - - - - - - - - - -I �I I I u op - \,•_Te-r ..-- -e as A•%' I Az 10 SIM/OPP 10 10 M CAR WASffl'd I E ISER 8i5 ' ti // I �33o S.F 22 33 7„ 300 13 S1tXtTS '� f I S1:EXITS 1 �) O„ O Tenant STAIR I SLOPE SLOPE A I 14 (E)OF FICE 109 13 Ilk ,,,���... \\\ I q - /•'' . a I 287.17 S.F. E VEST. - t e.: Artistic 65.93 S.F. /, ' . /150 - 2 114 ,8 < AUtoboCly V EXEMPT EPTf� "( I B:EXITS 1 (E)TOILET 44.05 S.F. \ I `A A LUJ' „ N 16 ,,, O /,DO = , 1 + ® 1 Repair Center �.N` • B:EXITS , �L � L M U 1 ,• 7.29 S.F. A ° d ® e I _ � MPT d l 1® 12 7875 SW Hunziker St. a Tigard, OR 97223 ,2 ® I aLMU21 1 I a < d°. A a ., e 17 13 Ln d 10 ,3 6 �), �, - ------------------------------------------ ---------------- -8Z d da ^- - 2 10 a Project: 40 a� Q. Al e ° A 16 m Paint Booths (N)PAINT 0 H I ® 1 WAR HOUSE I I --- -------------------------------------------------------------------- p A and Car VV ash I _ 115 1856.47 S. e 5350.62 S.F. O 300 = 7 I / _ 1. 300 = 18 -- --- ---------------------------------------------------------- SI:EXITS 7 20 16 1 d 4 C 18 ^1 7875 SW Hunziker St. A Ln Tigard, OR 97223 1 I I I I I I 1�1 0 111 ME ' 11 1s 24 24 Ln 14 Sheet Title: -� - - - - - - - - - - - - - - -- - -- - 1 10 Floor & - - - - - - - - - - - - - -' - _ � I ' ' 1 )-0" TYP.� ,s Fire Life Safety 5 0„ 17' 0„ 5 0„ 17 0), -� Plan Floor/Egress Plan I _ /8" = V-0„ I 27 ---- _� Keynotes - Floor Plan LANDiN _ _ ! LANDING Lr, 1. DEMO OPENING IN WALL AS SHOWN AT 7'-2" AFF. INSTALL NEW TIMELY FRAME TO FINISH OPENING. 8 g 2. CONCRETE CUT AT CAR WASH AREA AT DIMENSIONS AS SHOWN. SLOPE TO FLOOR DRAIN. SEE STRUCTURAL. --- 3. NEW PARTIAL HEIGHT WALL TO 8'-0" AFF. SEE DETAIL 1,2/A3, TYP. ALL SURFACES TO HAVE FULL-HT. UTILITE -� PANELS INSTALLED PER MANUFACTURER'S INSTRUCTIONS FOR WET CONDITIONS. PROVIDE WATERPROOF SEAL AT I Z, iL ALL JOINTS. PROVIDE 6" COVE BASE. 3 6 I + 24 7 I 4. FLOOR FINISH AT CAR WASH AREA TO BE PAINTED TO MATCH ADJACENT. Az --- --- - - - � Revisions: 5. PROVIDE HOT/COLD, WALL MOUNTED HOSE BIB AT 18" AFF - - - - - - - - _ 6. CUT SLAB TO INSTALL OIL-WATER SEPARATOR. VERIFY DIMENSIONS OF UNIT PRIOR TO CUTTING. 26 7. PROVIDE NEW LOCKING LEVER HARDWARE AT STAIR DOOR. Q p 8. CLEAN EXIT PATHWAY FLOOR, WALLS AND CEILINGS, ADD HANDRAILS ON BOTH SIDES PER DETAIL 6/A2. 9. PROVIDE NEW EGRESS LIGHTING AT STAIRWELL 28 29 28 10. NEW PAINT BOOTHS. 2 Enlarged Floor Plan 11. EXISTING LIGHTED EXIT SIGN 12. NEW LIGHTED EXIT SIGN Al 13. LIGHTED EXIT PATH - 36" WIDE PATH WTIH MIN. 1 FOOTCANDLE ILLUMINATION AT FLOOR LEVEL 14. EXISTING FIRE EXTINGUISHER Legend Fire / Life Safety Plan Room Symbol Legend 15. FIRE EXTINGUISHER NEW LOCATION. � 16. EXISTING OVERHEAD DOOR TO REMAIN. ' ROOM NAME 17. NEW CONCRETE RAMP TO PAINT BOOTH OPENING AS SHOWN. � EGRESS PATH-PROVIDE CODE MINIMUM LEVEL OF 18. 5'X5'X7"HIGH CONCRETE PAD AS SHOWN. 27 LIGHT ALONG PATH PER SECTION 2702.02.13 AND OFFICE ROOM NUMBER SECTION 1008. 19. PROVIDE 'UTILITE' WALL PANEL AT EXISTING WALL TO 8'-0" AFF. INSTALL PER MANUFACTURER SPECIFICATIONS. ROOM AREA/LOAD 101 MILDREN DESIGN GROUP, P.C., 2020, ALL PROVIDE 6" COVE BASE. L DING FACTOR -�� RIGHTS RESERVED© XXX/100: 2�� 20. EXISTING DOCK LEVELER -' EXIT LIGHT AC WITH BATTERY BACK-UP; NUMBER OF THESE DRAWINGS ARE THE PROPERTY OF DIRECTIONAL ARROW UNITS WHERE LINE OF SIGHT TO B: 2 E ITS T MILDREN DESIGN GROUP, P.C.. AND ARE NOT 21. EXISTING WOOD STAIR 35)I 0" 9'-0" Q -0" 9 -0)) OCCUPANTS TO N USED OR REPRODUCED I ANY U NEAREST EXIT IS OBSCURED. MANNER, EXCEPT WITH THE PRIOR WRITTEN 22. EXISTING METAL STAIR I NUMBER OF PERMISSION OF MILDREN DESIGN GROUP, P.C. 23. NEW FLOOR DRAIN. CONNECT TO OIL/WATER SEPARATOR. ------ OCCUPANCY GROUP PER EXITS PROVIDED IBC TABLE 1004.5/NUMBER Date: 19 August 2020 24. ADD BATT INSULATION TO FILL CAVITY, 2 LAYERS OF J" GYPSUM BOARD, FULL HEIGHT, FIRE TAPED. FIRE RATED EXISTING WALLS TO REMAIN SEALANT TOP AND BOTTOM PER DETAIL 7/A2. NON-SYMMETRICAL ASSEMBLY TO PROVIDE FIRE PROTECTION Drawn by: Checked by: FROM PAINT BOOTH SIDE OF WALL FOR WALL WTIHIN 3' OF SPRAY BOOTH PER OSSC 426.3.2.3.5, EXCEPTION 1. NEW PARTIAL HEIGHT WALL. REFER TO DETAIL 1A2 P11B CLT 25. MODIFY EXISTING STAIR TO ALIGN FOR MODULAR RAMP 26. NEW PREMANUFACTURED MODULAR ALUMINUM RAMP WITH MAX. SLOPE OF 8.337. GUARD AND HAND RAILS AS __ FIRE EXTINGUISHER. FINAL LOCATIONS TO BE Job Number: 120082 REQUIRED. HANDRAIL EXTENSIONS AS SHOWN. VERIFY ALL DIMENSIONS PRIOR TO ORDERING AND INSTALLING. APPROVED BY FIRE MARSHALL PRIOR TO 27. NEW ALUMINUM LANDING. VERIFY ALL DIMENSIONS PRIOR TO ORDERING AND INSTALLING. _� 3 Enlarged Floor Plan INSTALLATION PER O.F.C., TABLE 906.3(1). FOR LIGHT Sheet 28. NEW ACCESSIBLE PARKING SPACE. SEE DETAIL 8/A2 FOR SIGNAGE AND PAINTING DETAILS. HAZARD OCCUPANCY, LOCATE IN PLAIN VIEW EVERY / Al ,/4 - 1 -0 3,000 SQ. FT. OF FLOOR AREA WITH A MAXIMUM 29. STRIPED ACCESS AREA TRAVEL DISTANCE TO EXTINGUISHER OF 75 FEET. Building Permit Submittal - August 2020 Al MILDREN I 1 DESIGN I I SELF TAPPING METAL STAIR NOSING SCREWS AT TOP AND GROUP UTILITE PANEL I I BOTTOM BAR STOCK ARCHITECTURE I INTERIORS V-19 EDGE CAP TRIM I I 5 I I AZ 4875 SW Griffith Drive,Suite 300 O Iavveerton,Oregon 1X"0 O.D. STEEL PIPE RAIL, n 97005 I I PAINTED SILICONE CAULK ALL I 3 A2 I I I I JOINTS, TYP. I 4 I I I I I I I I UTILITE PANEL, TYP " GYPSUM GREENBOARD A2 I I I I I I I I I2" MIN I I STANDARD HANDRAIL BRACKET, o DOUBLED STUDS AT WALL END X FASTEN THROUGH WALL TO BACKING I I I 136"0 O.D. STEEL PIPE RAIL, X CD I i I TS 2 x 2 x )f6"-5'-0" O.C. o PAINTED AND AT ENDS OF WALL _I I I I 24" X 8' UTILITE INTERLOCKING PANEL I I 136"0 OD STD. STEEL PIPE SILICONE CAULK ALL JOINTS, TYP. I BAR STOCK HANDRAIL TYPICAL I I 24" X 8' UTILITE INTERLOCKING �,� I I %" GREENBOARD GYPSUM BOARD PANEL. SILICONE CAULK ALL N x I JOINTS, TYP. /L1n X 336" METAL STUDS AT 16" 0/C I RUBBER BASE I I T. FLUSH END CAP WELD O TS 2 x 2 x /16"-LOCATE AT ENDS AND I i AND GRIND SMOOTH I AT 5'-0" ON CENTER. 1 S I I I I I I I I Rx2" x8" WITH I I 6" RUBBER COVE BASE - ALL SIDES Ya I I (2) �"0 EXPANSION ANCHORS 3"0 x %" MOUNTING R WITH x (4) %" FLATHEAD SCREWS g WITH COUNTERSUNK HOLES x A �S� Ari-12079 1Partial Height Wall Section 2 Partial Height Wall Section 3 Handrail Re urn 4 Handrail Attachment 5 Typical Handrail A2 1 =1'-O" A2 1 "=1'-0" A2 Half Size A2 5Half B6 Size A2 3"=1'-O" "=1 -O s • x OF FIRE RATED SEALANT. EMERGENCY EGRESS LIGHT I I A2 FIXTURE EXISTING TOP TRACK. CD, g DO NOT SCREW GYPSUM I NEW LEVER DOOR \ I — o BOARD TO TRACK HARDWARE \/1 (:>� ;. li .090" ALUMINUM SIGN PLATE 1%"0 STEEL PIPE RESERVED WHITE RETRO-REFLECTIVE PARKING SHEETING J" HIGH GREEN RAIL \ RETRO-REFLECTIVE LETTERS BATT INSULATION TO FILL AND BORDER, BAKED ENAMEL BUILDING RETURN HANDRAIL I CCESSIBLE SIGNAGE Tenant EXTERIOR TO WALL CAVITY ER STATE4" PAINT STRIPES AT EQUIREMENTS 2'-0" 0/C TYPICAL HANDICAP SYMBOL WHITE Artistic RETRO-REFLECTIVE ON / WHEELSTOPBLUE RETRO-REFLECTIVE Autobody E V / BACKGROUND Az i all 4,5 0 4" PAINT STRIPE A2 0 36' TYP. VAN 1 VAN ACCESSIBLE SIGN, WHITE Repair Center (2) LAYER % TYPE 'Y' ACCESSIBLE SYMBOL, ACCESSIBLE RETRO-REFLECTIVE OPENING IN—// 1 _0 / STAGGER JOINTS, APPLY FIRE TAPE PAINTED PER STATE l BACKGROUND WITH GREEN CONC. WALL REQUIREMENTS pi NOTES: RETRO-REFLECTIVE TEXT 1. ALL ACCESSIBLE STRIPING 0l— ' AND SIGNAGE TO COMPLY GALVANIZED STEEL POST 7875 SW Hunziker St. — — — ZZ" WITH ORDINANCE ORS ' w 447.233. Tigard, OR 97223 3 — — — 18" 2. ACCESSIBLE SIGN TO BE Az EXISTING BOTTOM TRACK. I I _ CENTERED FOR STANDARD DO NOT SCREW GYPSUM I I N II (E) CONCRETE ACCESSIBLE SPACES. STAIRS BOARD TO TRACKI I 3. WHITE STRIPING PREFERRED NO II I I N BLUE BACKGROUND ANDIT II C a FIRE RATED SEALANT. J PARKIN BLUE OPTIONAL INTED CURB 1D DIRI I ac A2 4. MAXIMUM 2% SLOPE ALL 60" ECTIONS EXCEPT AT Project: RAMPS 9'-0" 8'-0" AT VAN 5. "NO PARKING' LETTERING I I Paint Booths AT AISLE TO BE WHITE I I TYPICAL ACCESSIBLE LOCATIONS AND RETROREFLECTIVE U and Car Wash s Stair Elevation 1-hour Wall with Deflection Connection $ Accessible Parking Stall s Accessible Van Parking Signage NON-SYMMETFICAEASSEMBLY A2 Y4„=1'-O„ A2 1„=1'-0„ G G Acce .PmkMq Stall G e_c_aSne pa•°ung "t, p 7875 SW Hunziker St. Tigard, OR 97223 6, 7„ Sheet Title: Details 7„ 32„ 3” WIDE PAINT STRIPE 0 TYPICAL .— N 86• N O I 67' 4' 10" Revisions: 2'-8$" to International Accessible Symbol International Accessible Symbol MILDREN DESIGN GROUP, P.C., 2020, ALL RIGHTS RESERVED THESE DRAWINGS ARE THE PROPERTY OF MILDREN DESIGN GROUP, P.C., AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, EXCEPT WITH THE PRIOR WRITTEN PERMISSION OF MILDREN DESIGN GROUP, P.C. Date: 19 August 2020 Drawn by: Checked by: PHB CLT Job Number: 120082 Sheet Building Permit Submittal - August 2020 A2 MILDREN DESIGN Building / Parking Data Site Data Keynotes GROUP ARCHITECTURE I INTERIORS BUILDING USES: BUILDING AREA: REQUIRED AREA RATIO: REQUIRED PARKING: REQUIRED BIKE: AREA: AREA: 9 COVERAGE: 1. EXISTING PARKING 4875 SW Griffith Drive,Suite 300 MIN-MAX/1000 SITE 206,752.4 S.F. (4.75 AC) 2. REMOVE PAINT STRIPPING AT INACTIVE LOADING AND NEW Beaverton,Oregon 97005 WAREHOUSE 66,405 S.F. 0.5-0.8/1000 33.2-53.12 33.2 X 100% = 34 0.1/1000 = 6.7 PARKING SPACE 01503244.0552 WAREHOUSE 9,000 S.F. 1.6-NONE/1000 14.4-NONE 14.4 X 859 = 13 0.1/1000 = 0.9 IMPERVIOUS AREA: 3. REPAINTED PARKING SPACE STRIPING VEHICLE REPAIR 6,000 S.F. 2-2.3/1000 12-13.8 12 X 70% = 9 0.2/1000 = 1.2 BUILDING (FOOTPRINT): 85,225 S.F. 41.22% 4. NEW PARKING SPACE - 4" WIDE WHITE STRIPE AT OFFICE 6.000 S.F. 2.7-3.1/1000 10.3-12.98 10.3 X 609 = 7 0.5/1000 = 1.9 PAVING AREA: 76.805.4 S.F. 37.159 16'-0"X9'-O" PARKING SPACE 85,225 S.F. 63 MIN - NO MAX 11 TOTAL IMPERVIOUS AREA: 162,028.4 S.F. 78.379 5. NEW ACCESSIBLE PARKING SPACE, AND SIGNAGE 6. NEW ACCESSIBLE RAMP AND RELOCATED STAIR TENANT: LANDSCAPE AREA: 7. EXISTING STRIPING AT NO PARKING AREA LANDSCAPING: 44,724 S.F. 21.639 8, EXISTING CHAINLINK FENCE WITH ROLLING GATE OFFICE 1,120 S.F. 9. EXISTING TRASH CONTAINER WAREHOUSE 13,865 S.F. 10. EXISTING MAIL BOX VEHICLE REPAIR 6,000 S.F. PARKING: # SPACES PROVIDED: 11. BIKE RACK FOR 2 BIKES (6 RACKS TOTAL FOR 12 BIKES) ACCESSIBLE: 2 12. 5'-0" WIDE PAINTED STRIPING AT PEDESTRIAN ACCESS TO ` STANDARD: 62 PUBLIC STREET \ TOTAL SPACES PROVIDED: 64 13. EXISTING SIDEWALK 14. SHARED ACCESS EASEMENT BIKE: 12 I Legend DRIVE-IN DOOR . DOCK-HIGH DOOR ® # OF PARKING SPACES 3 10 A 'J� ARI-12079 0' 0 9'-6" Fi LAN • 90'-0' 3 OREGON v 10 LAU % I' I` o I rI 16'- r , i I 2 , o 5 0" 1 O 17'_ 3 I � _ q w x x- x- 1 Tenant - . x 7 0 6 Artistic a - -- ----- Autobody EV 2 0 12 Repair Center I 2 - 35'r 0„ 26'-0,, / , ___ -_ ----- -- -------- 7875 SW Hunziker St. - " - ---- I Tigard, OR 97223 UTI LITY N D U ST R I L1� 2 CENTER A�. � Project: j - -- - - - ----- -- Paint Booths I ---- and Car Wash 15'-0" - --- --_ I -- - ----____ - 7875 SW Hunziker St. Tigard, OR 97223 136'_ ' r 0', N i I 9 ' 7 Sheet Title: Site Plan 1 10 4 16'-0', 12 I 9 � � N Ir 62 I I -- --- '---- - -, , - - I ----- - ---- - ----- 45'-0„ -_ Revisions: 9 3 t -- ---------- _ _ x _ I 9 - -- o - o � 8 1 10 -- - __ ti 16'-0" \ ---- ------------ ---- 2 108'-0" t 13 136'-0„ � R I i MILDREN DESIGN GROUP, P.C., 2020, ALL RIGHTS RESERVED i THESE DRAWINGS ARE THE PROPERTY OF -- - MILDREN DESIGN GROUP, P.C., AND ARE NOT TO BE USED OR REPRODUCED IN ANY --__ MANNER, EXCEPT WITH THE PRIOR WRITTEN -�--- PERMISSION OF MILDREN DESIGN GROUP, P.C. .� - -----------------------_J I Date: 19 August 2020 Drawn by: Checked by: Site Plan Enlarged Site Plan PHB CLT 1" = 40'-0" A3 1" = 10'-0" Job Number: 120082 Sheet Building Permit Submittal - August 2020 A3