Loading...
Plans (21) BUP2020 -00093 � Locust SIM RECEIVED J eso APR 01 2020 I III IIIIIIII 1 IIIIIIIIIIII _ O - = CITY OF TIGARD j ll BUILDING DIVISION MUC'WWMPAWONG _ 7TH FLOOR TOILET ROOMS Architecture Interiors — _ 41111M iPl IIIIINIIII Planning = Engineering n ulnHnl nnnunl LANDLORD IMPROVEMENT THE ISSUANCE OF A PERMIT a VALIDITY OF PERMIT • =C3 6 BASED ON CONSTRUCTION AD / O ` 5 LINCOLN DATA SHALL NON POTHER DOCUMENT REVEt T Portland, OR THE CODE OFFICIAL FROM 503.224.9560 REQUIRING THE CORRECTION Vancouver, WA gam' 102 00 S W G R E E N B U R G R D . OF ERRORS. OSSC 105.4 3Se tt e, WA TIGARD , OREGON 206.749.9993 i www.mcknze.com R LEGEND MACKENZIE . DESIGN DRIVEN I CLIENT GOCUSED OFFICE COPY 1 EXISTING CONSTRUCTION TO BE DEMOLISHED U Client _______ _ u f I J CITY OF TIGARD Gl�Titl ', RI;VIIi\SUED FOR CJDL COMPLIANCE Approved: ] 1�I{�}I}IH'{I{I F�} II�I 1 1 1 1 1 1 11 OIC.: I S H O R E S T E I N �tG P N EXISTING 1 HOUR RATED WALL TO REMAIN R. I I I I I I I I I I I I I I I I I I I I I I I Permit #: ' O>� O 9 .� EXISTING 2 HOUR RATED WALL TO REMAIN Address: 111 D• Suite #: sw Oak Street NEW WALL TO GYP BOARD CEILING, SEE 8/A5.21 INDEX OF D RAW I N G S By: Date: -) -� GENERAL GO.01 TITLE SHEET, SITE PLAN, KEY PLAN, CODE SUMMARY AND NOTES Project GFI NEW GFI DEDICATED OUTLET ARCHITECTURAL 7TH FLOOR A1.10 DEMOLITION PLAN, PARTIAL SEVENTH FLOOR PLAN, FINISH/DIMENSION PLAN, DEMO RCP, TOILET ROOMS NEW LIGHT SWITCH ON OCCUPANCY SENSOR REFLECTED CEILING PLAN AND NOTES os A5.20 INTERIOR DETAILS AND SCHEDULES LANDLORD 1 SITE MAPA5.21 DETAILS pA (ALT.) NEW ADA ACTUATOR BUTTON IMPROVEMENT 0.0 NOT TO SCALE FS 1021NCOLN 00 SW GREENBURG RD. EXISTING FIRE STROBE TO REMAIN TIGARD, OREGON AREA OF WORK CODE SUMMARY LEGEND � SCOPE OF WORK EXISTING FIRE EXTINGUISHER TO REMAIN THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR LANDLORD IMPROVEMENTS OF BUT EXIT ACCESS — — — —� — APPROXIMATELY 409 SQUARE FEET AT THE TOILET ROOMS ON THE SEVENTH OF SEVEN FLOORS. WORK C:) 30" 4g" TO INCLUDE DEMOLITION, NEW WALLS AND ADA UPGRADES. AREA OF WORK VALUATION: $49,000 P D. KI ING I I I / " ADA ACCESSIBLE TURNING m WOMEN MEN COMMON PATH OF EGRESS TRAVEL = 33'-7, 48..1 I I � I cj� � RADIUS AND ADA CLEAR y EXIT E) I I I `� FLOOR SPACE DESIGN/CODE DATA rl PORTLAND, OREGON GOVERNING CODE: 2019 OREGON STRUCTURAL SPECIALTY CODE ® --------- NEW ACCENT TILE AT VANITY, GL-1 OCCUPANCY: B OF CONSTRUCTION TYPE: TYPE I-B D ® ■ OCCUPANCYTENANT AREA: APPROXIMATELY 409 SQUARE FEET NEW WALL TILE, PT-2 L © MACKENZIE 2019 ALL RIGHTS RESERVED 1 REQUIRED EXIT, 1 EXIT PROVIDED PER TOILET ROOM. THESE DRAWINGS ARE THE PROPERTY OF PT-1, 1/3 OFFSET MACKENZIE AND ARE NOT TO BE USED BUILDING IS FULLY SPRINKLED AND HAS NFPA SMOKE DETECTION WITH ON SITE EMERGENCY OR REPRODUCED IN ANY MANNER, GENERATOR FOR FIRE/LIFE/SAFETY BACKUP POWER. WITHOUT PRIOR WRITTEN PERMISSION NEW GYP. BOARD CEILING, SEE 4/A5.21 REVISION SCHEDULE Delta Issued As Issue Date �• ' ''` EXISTING GYP. BOARD CEILING TO REMAIN SEPARATE PERMIT 2 CODE SUMMARY PLAN ' 2019 OSSC SECTION 107.3.4.2 (BY SEPARATE PERMIT) FIRE SPRINKLER 0,0 7TH FLOOR NTS DEMOLISHED CEILING GRID AND TILE FIRE ALARM MECHANICAL ELECTRICAL NEW RECESSED LINEAR LIGHT FIXTURE, LF-2 PLUMBING PROJECT GENE RAL NOTES O NEW RECESSED LINEAR LIGHT FIXTURE, LF-3 NOTE: DESIGN BUILDERS ARE FULLY RESPONSIBLE FOR THE DESIGN OF THESE SYSTEMS/COMPONENTS. NEW RECESSED SQUARE CAN LIGHT FIXTURE, LF-4 THESE SYSTEMS/COMPONENTS SHOWN ON DOCUMENTS ARE SCHEMATIC ONLY: THEY ARE NOT A. THE DRAWINGS LOCATE PRODUCTS, SURFACES, AND MATERIALS AND THE NOTES CONVEY DESIGN INTENT. THE PROJECT INTENT IS TO PROVIDE FOR A COMPLETE, WORKING SYSTEM. EXISTING SPRINKLER HEAD TO REMAIN INTENDED TO REPRESENT FINAUCODE COMPLIANT DESIGN. PROVIDE DESIGN DOCUMENT SUBMITTAL TO SHEET TITLE: B. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE LATEST ADOPTED BUILDING CODE EDITION, AND TO CONDITIONS AND SPECIFICATIONS OF ALL GOVERNING AUTHORITIES. ARCHITECT OF RECORD FOR REVIEW PRIOR TO SUBMITTAL TITLE SHEET + RELOCATE EXISTING SPRINKLER HEAD C. VERIFY AND CONFIRM ALL CONDITIONS, DIMENSIONS, AND LAYOUT INFORMATION PRIOR TO START OF CONSTRUCTION. NOTIFY MACKENZIE OF ANY DISCREPANCIES PRIOR TO START OF CONTACTS SITE PLAN, KEY WORK.ANY CORRECTION WORK REQUIRED AS A RESULT OF NOT REPORTING SUCH DISCREPANCIES SHALL BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. EXISTING CAN LIGHT FIXTURE TO REMAIN dF D. CONTRACTOR AND SUBCONTRACTORS SHALL CAREFULLY EXAMINE THE SITE AND THE CONSTRUCTION DOCUMENTS OF THE ENTIRE WORK. INCONSISTENCIES IN THE PLANS OR DEMOLISHED COVERPLATE ARCHITECT CONTRACTOR PLAN, CODE SPECIFICATIONS SHALL BE CALLED TO THE ATTENTION OF MACKENZIE. SUM MARY AN D E. REFER TO ENLARGED PLANS AND ELEVATIONS WHERE INDICATED FOR ADDITIONAL INFORMATION. ENLARGED PLANS TAKE PRECEDENCE OVER PLANS OF SMALLER SCALE,AND DETAILS SYMBOLS AND REFERENCES MACKENZIE RUSSELL CONSTRUCTION NOTES TAKE PRECEDENCE OVER PLANS. IN THE CASE OF A CONFLICT, THE HIGHEST COST OPTION SHOULD BE PRICED. 1515 SE WATER AVE, SUITE 100 20915 SW 105TH AVE PORTLAND, OR 97214 TUALATIN, OR 97062 F. DETAIL REFERENCES SHALL BE APPLIED TO ALL INSTANCES WHERE THE SAME CONDITIONS OCCUR, UNLESS NOTED OTHERWISE. PROJECT NORTH CONTACT: LINDSEY CARPENTER CONTACT: DONN STURDIVANT G. THE TERMS "ABOVE FINISH FLOOR" (AFF) AND "FINISH FLOOR ELEVATION" (FFE) REFER TO FINAL FINISHED FLOOR ELEVATION, WHETHER BUILT-UP SLAB, COMPOSITE DECK, OR RAISED TEL: 503.224.9560 TEL: 503.692.9002 DRAWN BY: KGB ACCESS FLOOR. Ty:TRUE NORTH FAX: 503.228.1285 EMAIL: DSTURDIVANT@RUSSELLCONSTRUCTION.COM EMAIL: LCARPENTER@MCKNZE.COM CCB: 58918 CHECKED BY: MRT, PDK H. DO NOT SCALE DRAWINGS. FILLED ARROW I. CUTTING AND DRILLING OF STRUCTURAL MEMBERS NOT DETAILED REQUIRES THE WRITTEN PERMISSION OF THE STRUCTURAL ENGINEER OF RECORD. A DETAIL# SHEET: INTERIOR ELEVATION LANDLORD/OWNER J. SAVE AND RECYCLE DEMOLITION DEBRIS AS APPLICABLE. ALL DEMOLISHED OR REMOVED EXISTING MATERIAL SHALL BE LEGALLY DISPOSED. COORDINATE WITH CITY OF TIGARD KEY MARK 12 REQUIREMENTS FOR RECYCLING/RE-USE OF DEMOLITION DEBRIS. SHEET# SHORENSTEIN REALTY SERVICES A CITY OF TIGARD G0m01 SUB-CATEGORY 5335 MEADOWS ROAD, SUITE 275 K. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE RESULTING FROM THEIR WORK. THE CONTRACTOR WILL COORDINATE CLEAN UP OF ALL AREAS AFFECTED BY DUST OR ANY CATEGORY LAKE OSWEGO, OREGON 97035 pprOved b MATERIALS, BOTH DURING CONSTRUCTION AND UPON COMPLETION OF THE PROJECT, INCLUDING THE INSIDE OF ALL WINDOWS AS NECESSARY SO THAT THE SPACE IS READY FOR Date: Y Planning OCCUPANCY BY TENANT. CONTACT: ROB FABIAN _ _ KEYNOTE 1 TEL: 503.412.4844 Initials: JOB NO. L. ALL DESIGN-BUILD ITEMS, SYSTEMS, AND ELEMENTS ARE TO BE SUBMITTED FOR REVIEW AND APPROVED BY MACKENZIE. EMAIL: RFABIAN@SHORENSTEIN.COM --- 2190950.06 M. EXISTING MATERIAL NOTED TO BE RETURNED TO THE OWNER SHALL BE SAFELY STORED AND PROTECTED UNTIL IT IS REMOVED FROM THE SITE BY THE OWNER. CONTRACTOR SHALL SPACE NAME OFFIC SPACE # PERMIT SET. 03/26/2020 COORDINATE WITH THE OWNER. ROOM/SPACE IDENTIFICATION 114 '219095006'C:\TEMPWCPUBLISH 14908\O6 G0.01.DWG CAK 03/26/20 13:07 1:96.00 GENERAL DEMOLITION NOTES A. REMOVE EXISTING FLOORING, WALL TILE, FRP PANELING, VANITY, SINKS,TOILETS, URINALS, PARTITIONS, WALL MOUNTED LIGHTING AND WALL MOUNTED MIRRORS THROUGHOUT. PATCH, REPAIR AND PREP SUBSTRATES AS REQUIRED TO RECEIVE NEW FINISHES. SEE SHEET A5.20 FOR FINISHES. MAINTAIN ALL EXISTING PLUMBING LOCATIONS FOR RE-USE, UNLESS NOTED OTHERWISE. B. THE CONTRACTOR SHALL CAREFULLY EXAMINE CONSTRUCTION DOCUMENTS FOR THE WORK. ANY CONFLICTS, INCLUDING BUT NOT . LIMITED TO BUILT CONDITIONS OF M.E.P. IN THE PLANS SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT/DESIGNER, SO THAT THE CLARIFICATION CAN BE ISSUED. C. SALVAGE ALL DEMOLISHED COMPONENTS AS POSSIBLE. RETURN TO LANDLORD FOR FUTURE USE, IF REQUIRED. Architecture ,. Interiors FULL FULL D. SAVE AND RECYCLE DEMOLITION DEBRIS WHERE POSSIBLE. COORDINATE WITH CITY OF TIGARD REQUIREMENTS FOR RECYCLING 25 25 TILE TILE DEMOLITION DEBRIS. Planning -, Engineering E. CAP ALL ABANDONED PLUMBING, ELECTRICAL CONDUIT, AND OTHER UNDER SLAB UTILITIES AS REQUIRED. - - _ F. EXISTING STRUCTURE TO BE LEFT UNDISTURBED AND INTACT. PERFORM NO DEMOLITION THAT MAY COMPROMISE THE STRUCTURAL S S _JLu J W INTEGRITY OF THE BUILDING WITHOUT WRITTEN APPROVAL OF THE ARCHITECT/DESIGNER. 1 17 GENERAL NOTES Portland, OR FE 14 L VESTIBULE _J 14 A. ALL EXISTING CONDITIONS TO REMAIN, EXCEPT NOTED BELOW. 503.224.9560 701 w I B. DIMENSIONS REFLECT FACE OF FINISH TO FACE OF FINISH, UNLESS NOTED OTHERWISE. Vancouver, WA C. WALL THICKNESS ARE NOMINAL,D. ALL INTERIOR DOORS TO BE EXISTING.SS NOTED OTHERWISE. 3Sealtle?WA j > 13 1 S 25 18 E. OUTLETS INDICATED ARE EXISTING UNLESS NOTED OTHERWISE. SITE VERIFICATION HAS BEEN PERFORMED (ON 09/23/2019, WHILE Seattle, WA F• 'r `' + 0' o 2O OCCUPIED) AND PLAN, ELECTRICAL AND CEILING INFORMATION HAS BEEN UPDATED (OBSERVATION IS LIMITED TO e I 2 18 - o - VISIBLE/ACCESSIBLE AREAS). CONTRACTOR TO FIELD VERIFY AND CONFIRM ADDITIONAL REQUIREMENTS WITH TENANT. WWW.mcknze.com A5.20 3 J A5.20 _ 16 �- - ❑ F. ELECTRICAL, DATA AND SWITCHING LOCATIONS INDICATED ARE SHOWN TO CONVEY GENERAL INTENT ONLY. COORDINATE a ^ _ I ❑ \ 14 - 7 1 ❑i ELECTRICAUDATA SWITCHING REQUIREMENTS WITH TENANT AND PROVIDE DRAWINGS BY SEPARATE PERMIT. M AC K E N Z I E 0•• U) [ ' o _� i 3_ G. ALL DIMENSIONS SHOWN AS PLUS/MINUS (�) ARE FOR GENERAL LAYOUT AND REFERENCE ONLY. VERIFY AND CONFIRM ALLccl ocsiaw DRIVEN i CLIENT FOCUSED 2 WOMEN'S TOILET MEN'S TOILET 10- 71 o DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO START 702 13 703 -6OF WORK. Client -•=_-:' - H. PATCH AND REPAIR ALL EXISTING WALLS WHERE AFFECTED BY NEW CONSTRUCTION. -----' 14 22 _ I. MODIFY EXISTING PLUMBING ROUGH-IN LOCATIONS AND/OR BLOCKING AS REQUIRED TO MEET ADA MOUNTING HEIGHTS AND ----- _ ________ _ - REQUIREMENTS. 22 5 J I J. CONTRACTOR TO NOTIFY A/E AND LANDLORD IF ISOLATION SHUT-OFF VALVE IS NOT EXISTING AT TOILET ROOMS. CONTRACTOR TO 7 = I PROVIDE PRICING TO LANDLORD FOR NEW SHUT OFF VALVE AT HOT AND COLD WATER SUPPLY. PROVIDE ACCESS PANEL, LOCATION ' = AND FINISH TBD. s n 0 R E S T E I N L91 12 6 @17m K. CONTRACTOR TO NOTIFY A/E AND LANDLORD IF DRAIN IS NOT EXISTING AT TOILET ROOMS. CONTRACTOR TO PROVIDE PRICING TO i• - LANDLORD FOR NEW DRAIN AT EACH ROOM. LANDLORD TO CONFIRM FINAL LOCATION AND FINISH. „ ---- TYP __._________ t 0 2" MI L. PREP ALL SURFACES TO FACILITATE PROPER FLUSH TILE INSTALLATION. INSTALL PER CURRENT TCA METHODS. INSTALLATION OF "----------------- _ IMPERFECT PRODUCT IS NOT ACCEPTABLE. ® M. PAINT ALL WALLS AND GYPSUM CEILINGS. NO VOC PAINT SYSTEMS TO BE UTILIZED, TO INCLUDE PRIMERS AS WELL AS FINISH 1 ----- . 1 - - - - -' \ N CONFIRM L J L J PRODUCTS \ / 21 21 . GROUT JOINTS IN FLOOR TILE TO ALIGN WITH GROUT JOINTS IN CUT BASE TILE. GROUT JOINT REQUESTED TO BE 1e". CO Project .----------- -` / MANUFACTURER RECOMMENDED GROUT JOINT SIZE, NOTIFY ARCHITECT OF ANY CONCERNS PRIOR TO INSTALL. 7TH FLOOR ------ _�n=="=, ------'�_==""__€ "€z*='; / �p O. CONTRACTOR TO ENSURE FLOOR TILE IS ADEQUATELY SLOPED AT EXISTING FLOOR DRAIN LOCATIONS. CUT TILE INTO SMALLER r PIECES AS REQUIRED TO OBTAIN PROPER SLOPE SURROUNDING DRAIN. 4 T - - TOILET ROOMS 4 P. CONTRACTOR TO COORDINATE PRE-INSTALLATION MEETING ON-SITE WITH ARCHITECT/LANDLORD AND TILE INSTALLER FOR FINAL g 8 T LAYOUTREVIEWPRIORTOINSTALLATION. LANDLORD = -= \� �' ENT Q INSULATE PIPES BELOW SINK PER CODE IMPROVEMENT R. ACCESSORIES AND EQUIPMENT TO MATCH FIRST FLOOR TOILET ROOM SPECIFICATIONS. LANDLORD TO APPROVE ALL ITEMS PRIOR - TO ORDER AND INSTALL, 5 LINCOLN S. RE-USE OR MODIFY EXISTING PLUMBING LOCATIONS, IF FEASIBLE. PROVIDE NEW PLUMBING AS REQUIRED BY NEW LAYOUT. 10200 SW GREENBI.IRG RD. T. MODIFY EXISTING PLUMBING ROUGH-IN LOCATIONS AND/OR BLOCKING AS REQUIRED TO MEET ADA MOUNTING HEIGHTS AND TIGARD, OREGON REQUIREMENTS. U. CONTRACTOR TO NOTIFY A/E AND LANDLORD IF ISOLATION SHUT-OFF VALVE IS NOT EXISTING AT TOILET ROOMS. CONTRACTOR TO PROVIDE PRICING TO LANDLORD FOR NEW SHUT OFF VALVE AT HOT AND COLD WATER SUPPLY. PROVIDE ACCESS PANEL, LOCATION 1 DEMOLITION PLAN 2 PARTIAL SEVENTH FLOOR PLAN 3 FINISH/DIMENSION PLAN AND FINISH TBD. A1.10 A1.10 V. CONTRACTOR TO NOTIFY A/E AND LANDLORD IF DRAIN IS NOT EXISTING AT TOILET ROOMS. CONTRACTOR TO PROVIDE PRICING TO LANDLORD FOR NEW DRAIN AT EACH ROOM. LANDLORD TO CONFIRM FINAL LOCATION AND FINISH. W. HVAC CONTRACTOR TO PROVIDE FULL SHEET OF THE FLOOR AFFECTED UPON COMPLETION. CONTRACTOR IS RESPONSIBLE TO r PROGRAM THE OVERRIDE HVAC BUTTON. X. CONTRACTOR TO REVIEW EXISTING CONDITION OF ALL CEILING DEVICES WITH LANDLORD AND PROVIDE NEW AS REQUIRED. Y. SUSPENDED ACOUSTICAL TILE CEILINGS AT 8'-9"+ AFF, UNLESS NOTED OTHERWISE. NEW GYP. CEILING TO MATCH EXISTING HEIGHT. �n PORTLAND, OREGON Z. LIGHTING LAYOUT IS SHOWN FOR PRELIMINARY DESIGN INTENT ONLY. FINAL LIGHTING LAYOUT TO BE PROVIDED BY THE ELECTRICAL '�i CONTRACTOR AND IS DEPENDANT ON OREGON ENERGY CODE ALLOWANCES AND EXISTING BUILDING INFRASTRUCTURE IN CEILING. ELECTRICA NTRACTOR REVIEW ALL REQUIRED LIGHTING LEVELS AND F ANY CONCERNSLOFOFOOTCAND E3 OR FIXTURE PLACEMENT//LOCATION WITHIN ANYAREAOFOTHE SPACN AND E.I CONFIRM NEW FY ARCHITECT OLIG T FIXTURE OF PLACEMENT DOES NOT INTERFERE WITH NEW WALL CONSTRUCTION AND SAT MAIN GRID LINES, RELOCATE IF REQUIRED. FINAL EQ EQ EQ EQ LAYOUT TO BE REVIEWED AND APPROVED BY LOCAL JURISDICTION THROUGH SEPARATE PERMIT. IE 2019 KEYNOTES © ALL�RIGHTS ZRESERVED - - - - - THESE DRAWINGS ARE THE PROPERTY OF 1. EXISTING FLOOR DRAIN LOCATION TO RECEIVE NEW FLOOR DRAIN. COORDINATE FINAL FINISH WITH LANDLORD. MACKENZIE AND ARE NOT To BE USED OR REPRODUCED IN ANY MANNER j_ REQUIRED. CONFIRM FINAL SPECIFICATION WITH LANDLORD WITHOUT PRIOR WRITTEN PERMISSION W W 2. SALVAGE EXISTING AUTO SOAP DISPENSER FOR RE-USE, IF IN GOOD WORKING ORDER. PROVIDE NEW, IF RE : - +'O. U: +: f : ;0 + 3. PROVIDE NEW SHORENSTEIN STANDARD AUTO FAUCET. CONFIRM FINAL SPECIFICATIONS WITH LANDLORD. G. ;A . . -' - 4 TOILET WITH THE CODE REQUIRED ADJACENT SIDE ADA GRAB BARS AND VERTICAL GRAB BAR AT EXISTING PLUMBING REVISIONS SCHEDULE t0 LC3 1LJ Y LOCATION. S A/A PRO S OPERATION, SS - EXISTING PROVIDE NEW SHORENSTEIN STANDARD PORCELAIN LOW FLOW WALL MOUNTED ADA HEIGHT TO C % EQ " EQ ' ' L ATI N. EE DETAIL 9 5.20. VIDE DUAL FLUSH PERATI N, A UME SLOAN UPPERCUT. Delta Issued As Issue Date -t- --------- '` 5 SHORENSTEIN STANDARD PORCELAIN, OW FLOW WALL MOUNTED ADA HEIGHT URINAL PROVIDE MODIFIED PLUMBING LOCATION PER NEW FIXTURE PLACEMEN PROVIDE NEW AS REQUIRED SEE PROVIDE NEW SH N, L T, - -----------'-------- LF DETAIL 9H/A5.20. +,T:' ? i l------ ---- --- --------- ----- 4 ''•. ii i - c 6. PROVIDE NEW SHORENSTEIN STANDARD PORCELAIN LOW FLOW WALL MOUNTED STANDARD HEIGHT URINAL. PROVIDE MODIFIED PLUMBING LOCATIONPER NEW FIXTURE PLA E CEMENT PROVIDE NEW AS REQUIRED ' 7. PROVIDE NEW SHORENSTEIN STANDARD PORCELAIN, LOW FLOW WALL MOUNTED STANDARD HEIGHT TOILET. PROVIDE MODIFIED PLUMBING LOCATION PER NEW FIXTURE PLACEMENT, PROVIDE NEW AS REQUIRED. 24 ----------------------- _ - - - T YP. i .23 --------------------- ----- -------- PROVIDE DUAL FLUSH OPERATION ASSUME SLOAN UPPERCUT. T� i •JI(• ,t •W T ; B. NEW RECESSED MOUNT COMBINATION TOILET PAPER DISPENSER, SEAT COVER DISPENSER. SEE 9G/A5.20. 4- 111141111.1111 Booms----------- ------ `: 8'-9" AFF 8'-9" AFF ER SANITARY NAPKIN RECEPTACLE. SEE 9G/A5.20. : ' 9 NEW RECESSED MOUNT COMBINATION TOILET PAP DISPENSER SEAT COVER DISPENSER AND 10 TOILET T V SANITARY NAPKIN RECEPTACLE SEE 9G/A5.20. --------- --T___________ ----------------------------------- ,: NEW SHARED O LET PARTITION MOUNTED COMBINATION TOILET PAPER DISPENSER, SEA COVER DISPENSER, AND --- `""" NEW TOILET PARTITION MOUNTED COMBINATION TOILET PAPER DISPENSER ---------------- --------7-----------------r--•-- -----------1------------ -------- ------- EAT COVER DISPENSER. SEE 9G/A5.20. •' " 11 S SHEET TITLE' _ 12. NEW 6'H METAL FLOOR MOUNT TOILET PARTITION WALLS AND DOORS, SL-1. DEMOLITION PLAN, LF -------------------- -' ; ! _. :: 4W1.. . .:.: � :> 5. NTH 13 NEW PARTIALLY RECESSED PAPER TOWEL DISPENSER UNIT, AC 1 SEE 9F/A 20 PROVIDE POWER AS REQUIRED MAINTAIN EXISTING WALL RATING AS REQUIRED PARTIAL SEVENTH _------------- ----------- FINISH/DIMENSION NEW PARTIALLY RECESSED WASTE RECEPTACLE UNIT, AC-2. SEE 9F/A5.20. NOTIFY A/E IF WALL DOES NOT PROVIDE ENOUGH INTERNAL CLEARANCE FOR EQUIPMENT. MAINTAIN EXISTING WALL RATING AS REQUIRED. FLOOR PLAN, - --- ---------- --------------- ---------- PLAN, - +,•.__._.__+ ¢ 1 ; :_ 15. NEW SOLID SURFACE VANITY COUNTERTOP, WITH 6"X6" SQUARE OPENING FOR WASTE, 2" BACKSPLASH, SS-1,AND NEW RECTILINEAR UNDERMOUNT SINKS, SI-1. FINISH/DIMENSION ;, .• ; ------------------------ ----------- ----- ,. .': PLAN, DEMO RCP, - j 16. NEW 24"WIDE BY 48" HIGH BACKLIT MIRRORS, LF-1, CENTERED OVER EACH SINK. PROVIDE 60"± AFF POWER CENTERED ABOVE EACH SINK TO POWER MIRRORS. COORDINATE FINAL POWER REQUIREMENTS WITH ! ! REFLECTED CEILING = _ --- MANUFACTURER. PLAN AND NOTES , ANUFACTURER 17. PROVIDE SCHLUTER TRIM AT EXISTING CARPET AND NEW TILE TRANSITION, BRUSHED ALUMINUM. SEE DETAIL 12/A5.20. TRANSITION TO ALIGN WITH CENTER OF DOORWAY. U. -i--------•---+-----------i----------+ + I ___________i______.____1_..`.__I'___i________ 18. NEW 12"X24" PORCELAIN TILE FLOOR T- AND 6 X24 PORCELAIN CUT TILE BAS T-1 B. 12"X24" FLOOR TILE TO BE OFFSET AT 5 PER TCNA STANDARDS. PROVIDE SCHLUTER TRIM AT ALL EXPOSED TILE EDGES, W . •>. S P 1 A E P BRUSHED ALUMINUM. SEAL ALL GROUT PER MANUFACTURER'S INSTRUCTIONS. USE EPDXY GROUT THROUGHOUT. COLOR TO MATCH ADJACENT GROUT.L =SEE DRAWN BY: KGB - - - i----------- -- CA Y S O 19. NEW WALL TILE, PT-2, 12"X4"TILE ALONG WALLS WHERE INDICATED B - -. PROVIDE SCHLUTER TRIM AT ALL EXPOSED TILE EDGES, BRUSHED ALUMINUM. USE EPDXY GROUT THROUGHOUT. CHECKED BY: MRT, PDK IMMMMEM INE EQ EQ EQ E 20. NEW GLASS MOSAIC TILE AT VANITY WHERE INDICATED BY ---, GL-1. USE EPDXY GROUT THROUGHOUT. SHEET: 21. NEW FLOOR TILE, PT-1, T BE CUT AROUND DRAIN TO ENSURE PROPER SLOPE IS MAINTAINED. 22. PROVIDE NEW SHORENSTEIN STANDARD AIR FRESHENERS. COORDINATE FINAL SPECIFICATION AND LOCATIONS WITH LANDLORD. A1m10 4 DEMO RCP 5 REFLECTED CEILING PLAN 23. PROVIDE NEW GYPSUM CEILING THROUGHOUT. ASSUME TO MATCH EXISTING HEIGHT OF 8'-9"± AFF. PREP CEILING TO RECEIVE NEW PAINT, P-1. PROVIDE CEILING ACCESS PANELS AS REQUIRED. CONFIRM FINAL SPECIFICATIONS WITH LANDLORD. PROVIDE LIGHT FIXTURES, LF-2, LF-3 AND LF-4. NOTIFY A/E OF ANY EQUIPMENT CONFLICTS. A1.10 1/4"=1'-0" A1.10 1/4"=I'-O" 24. RELOCATE EXISTING CEILING COMPONENTS AS REQUIRED AND WHERE AFFECTED BY NEW CEILING AND PROPOSED LIGHTING LAYOUT. -_ 25. NEW ADA ACTUATOR BUTTON. CONCEAL NEW MECHANICS ABOVE EXISTING CEILING, IF FEASIBLE. PROVIDE ELECTRICAL STRIKE, PASSAGE LATCHSET F75 FUNCTION, AND DOOR H/C OPERATOR TO EXISTING DOOR. JOB NO. 2190950.06 ADA ACTUATOR BUTTON ON EACH SIDE OF THE DOOR AND ACCESS CONTROL OF DOOR TO PROVIDE THE FOLLOWING SEQUENCE: PRESSING THE ACTUATOR BUTTON RELEASES THE ELECTRIC STRIKE PRIOR TO ACTUATION OPERATION. PERMIT SET: 03/26/2020 '219095006'C:\TEMPVACPUBLISH 14908\06 A1.10.DWG CAK 03/26/20 13:07 1:96.00 NOTE: SCHEDULE OF INTERIOR FINISHES SCHEDULE OF TOILET FIXTURES 1. VERIFY FINAL TILE LAYOUT FOR APPROVAL PRIOR TO INSTALLATION. 1 1 SL-1: TOILET PARTITIONS:HADRIAN,#4 BRUSHED STAINLESS STEEL,85"TALL 2. INSTALL WALL TILE, PT-2, TO EXTEND (1) FULL 5.2 PT-1: FLOOR TILE:PENTAL,FRAY,SAND,12"X24'AT FLOORS,3 OFFSET.GROUT JOINT TO BE "WIDE, PER MANUFACTURER'S TILE HEIGHT PAST TOP OF VERTICAL GRAB BAR. STANDARDS. SI-1: KOHLER,CAXTON K-2000,UNDER-MOUNT BATHROOM SINK,0 WHITE 3. SINK CENTERED WITH CENTER OF CABINET OPENING. PT-1B:ASSUME CUT PT-1@6'x24"FORBASE TILE. 4. MIRRORS CENTERED OVER SINKS. PROVIDE 60"t AFF 17"� 24" 8"' BRUSHED ALUMINUM PORCELAIN AC-1: GEORGIA-PACIFIC,SEMI-RECESSED AUTOMATIC PAPER TOWEL DISPENSER,59466A,STAINLESS STEEL POWER CENTERED ABOVE EACH SINK TO POWER SCHLUTER STRIP AT TILE, PT-2 ■ PT-2: WALL TILE:UNITED TILE,CROSSVILLE,RETROACTIVE,EMPRESS WHITE,A215,POLISHED,4"X12'AT WALLS.GROUT JOINT TO AC-2: BOBRICK,RECESSED WASTE RECEPTACLE,B-43644 WITH LINERMATE,SATIN FINISH STAINLESS STEEL MIRRORS. COORDINATE FINAL POWER REQUIREMENTS - _ EXPOSED TILE EDGES BE*, WIDE,PER MANUFACTURER'S STANDARDS. WITH MANUFACTURER. SL-1 Architecture Interiors GL-1: GLASS MOSAIC ACCENT TILE:DALTILE,COLORWAVE,CW08 WISTERIA, GLASS TILE, GL-1 1X1 GLASS MOSAIC AT VANITY WALLS.GROUT JOINT TO BE*'WIDE. -- Planning Engineering GT-1: GROUT:CUSTOM,386,OYSTER GRAY,EPDXY,NON-SANDED,�g" R O O M F I N I S H S C H E D U L E BACKLIT MIRRORS, LF-1 GROUT JOINT. j P-1: FIELD PAINT:SHERWIN WILUAMS,SW 7012 CREAMY.FINISH TO HAVE A MASTER PAINTER INDEX OF 3 WITH A GOOD SCRUB ROOM ROOM NAME MATOLR M TL N Nr EAV� sM pT MATLL C EILING FINISH CEILING 6X6 ' FINISHED EDGE / RATING AND SHEEN AT 15%-25%AT 60 DEGREES. FINISH FINISH FINISH FINISH FINISH FINISH MArL COMMENTS CUT-OUT 701 VESTIBULE IST i P-2: ACCENT PAINT:SHERWIN WILLIAMS,SW7D36 ACCESSIBLE BEIGE.FINISH TO HAVE A MASTER PAINTER INDEX OF 3 WITH A 702 WOMEN•STOILET P-1 PT-1B P/PT-2 P/Pr-2/GL-1 P/Pr-2 P GB 2,3,4 RELOCATED AUTOMATIC - GOOD SCRUB RATING AND SHEEN ATI5%-25%AT 60 DEGREES. M MEN'S PT-1 Pr-1B P/PT-2 P P/PT-2 PMT-2/GLA GB 2.3.4 SOAP DISPENSERS - FINISHSCHEDULENOTES: `r _ Portland, OR SS-1: SOLID SURFACE:PENTAL QUARTZ,PEARL WHITE,POLISHED,2CM A. PATCH AND REPAIR ALL EXISTING WALLS WHERE AFFECTED BY NEW WORK PAINT ALL WALLS AND GYPSUM CEIUNG. CENTER SINK W/CABINET �� 503.224.9560 PL-1: PLASTIC LAMINATE:FORMICA,SILVER RIFTWOOD,6413-NG,NATURAL GRAIN(GRAIN DIRECTION:VERTICAL,BLACK MELAMINE U PROVIDE NEW FLOOR FINISH AND CUT TILE BASE THROUGHOUT. OPENING, TYP. Vancouver, WA INTERIOR) FINISH SCHEDULE COMMENTS: WASTE RECEPTACLE UNDER COUNTER 360.695.7879 ABBREVIATIONS: O NOTE:EGGSHELL WASHABLE FINISH AT CEIUNG AND SOFFITS,SATIN WASHABLE FINISH AT WALLS.SEMI-GLOSS FINISH AT ALL i. PATCH AND REPAIR VESTIBULE IF AFFECTED BY NEW CONSTRUCTION TO MATCH WSTING ADJACENT FINISHES. I LO TOILET ROOM WALLS AND CEILINGS. 2. ASSUME P-1 UNLESS NOTED OTHERWISE ON FINISH PLAN,3/A1.10. PT PORCELAIN TILE SOLID SURFACE COUNTERTOP, I Seattle, WA 3. PROVIDE NEW GYPSUM BOARD CEIUNG THROUGHOUT.PREP CEILING TO RECEIVE NEW PAINT,P-1.PROVIDE CEIUNG GL GLASS TILE -to 206.749.9993 ACCESS PANELS AS REQUIRED,PAINTED TO MATCH.CONFIRM FINAL SPECIFICATIONS WITH LANDLORD. EXIST EXISTING SS-I AND 2" BACKSPLASH/ 4, PT-2 AT LOCATIONS INDICATED ON3/A1.10ONLY. GB GYPSUM BOARD SIDE SPLASH - I www.mcknze.com SCHEDULE OF LIGHT FIXTURES P PAINT LOCKING LOWER CABINETRY ON o NON-ADA APPROACH SIDE ONLY N / I I z MACKENZIE. LF-1: SEURA,LED BACKLIT MIRROR,HALO DESIGN,CUSTOM 24X48"SIZE,DIMMABLE (SEE FLOOR PLAN) W DESIGN DRIVEN I CLIENT FOCUSED FOR COMPLETE INSTALLATION RECOMMENDATIONS CONTACT: PLASTIC LAMINATE, PL-1 3 Client LESLIE FLOHR OPEN TO BELOW, PER 3'-5" 3'-5" UT TILE, PT-1 LESLIE FLOHR CONSULTING H- 206-852-9360 CODE, FLOORING TO LESLIE@LESUEFLOHRCONSULTING.COM6 -10„ EXTEND UNDER CABINET VERIFY LF-2: FLUXWERX,NOTCH 2,LINEAR RECESSED LED LIGHT FIXTURE,TRIMLESS,8'WIDE 1 LF-3: FLUXWERX,NOTCH 2,LINEAR RECESSED LED LIGHT FIXTURE,TRIMLESS,5'WIDE 3 VANITY AND WALL ELEVATION W 5 H O R E 5 T E I N J W LF-4: LITHONIA,SQUARE SERIES,LDN4,RECESSED LED LIGHT FIXTURE,4'x4' 2 -1 -0 I FOR COMPLETE INSTALLATION RECOMMENDATIONS CONTACT: 5,2 © WOMEN'S TOILET 702 1/ J ROBBIE KENAGIE @ NOTE: HARRY L.STEARNS 503-201-7690 1. VERIFY FINAL TILE LAYOUT FOR APPROVAL PRIOR TO INSTALLATION. 'FINAL LIGHT FIXTURE SPECIFICATIONS ARE T8D AND TO BE REVIEWED BY SELECTED VENDOR PRIOR TO PROJECT START.ENSURE ALL 2. INSTALL WALL TILE, PT-2, TO EXTEND (1) FULL TILE HEIGHT PAST TOP OF VERTICAL GRAB BAR. GLASS TILE, GL-1 Project NEW FIXTURES HAVE SAME COLOR TEMPERATURE.A/E TO REVIEW LIGHTING SUBMITTAL PRIOR TO PROCUREMENT. 3. SINK CENTERED WITH CENTER OF CABINET OPENING. 7TH FLOOR 4. MIRRORS CENTERED OVER SINKS. PROVIDE 60"t AFF POWER CENTERED ABOVE EACH SINK TO POWER MIRRORS. 11 MEANS AND METHODS COORDINATE FINAL POWER REQUIREMENTS WITH MANUFACTURER. 5.2 TOILET ROOMS LANDLORD 09680 CARPET BRUSHED ALUMINUM PORCELAIN •• 24" 9"f 24" •' . BACKLIT MIRRORS, LF-1 IMPROVEMENT 1. REMOVE ALL EXISTING CARPET AT AREA OF WORK.PREP FLOOR TO RECEIVE NEW CARPET. SCHLUTER STRIP AT TILE, PT-2 2. INSTALL ALL CARPETS PER MANUFACTURER'S INSTRUCTIONS. EXPOSED TILE EDGES6"x6" FINISHED EDGE 5 LINCOLN 3. CARPET MEASUREMENTS TO BE FIELD VERIFIED PRIOR TO ORDER OF CARPET. !; ---- - - - CUT-OUT 10200 SW G REEN BU RG RD. 4. SEAL ALL CUT EDGES AT SEAMS AT CARPET INSET TO PREVENT RAVELING.NOTIFY A/E OF ANY CONCERNS PRIOR TO ORDER. SL-1 ELOCATED AUTOMATIC SOAP TIGARD, OREGON 09900 PAINT DISPENSERS 1. THE OUTLINED PAINT SPECIFICATIONS MAY BE MATCHED BY OTHER MANUFACTURERS. ACCEPTABLE MANUFACTURERS:BENJAMIN MOORE,SHERWIN WILUAMS,MILLER, OR APPROVED SUBSTITUTION.SUBMIT RECOMMENDED SHEEN WITH DRAW DOWNS FOR A/E REVIEW AND APPROVAL. / CENTER SINK W CABINET ,^� 2. PROVIDE ONE COAT PRIMER AND TWO COATS PAINT ON ALL GYPSUM BOARD SURFACES. - / OPENING, TYP.W/ SY' �'�Tf 3. CONTRACTOR SHALL PROVIDE ONE FULL GALLON OF EACH WALL COLOR PAINT WITH LABELS TO OWNER UPON COMPLETION OF THE PROJECT. LABEL ALL LEFTOVER PAINT AND STORE AS DIRECTED BY OWNER. " h� P D. KI ING 4. DISPOSE OF ALL PAINT MATERIALS OFF SITE. DO NOT POUR DOWN DRAINS,CATCH BASINS,OR IN LANDSCAPE AREAS. d C SOLID SURFACE COUNTERTOP, v Ol 5. SUBMIT PAINT DRAW DOWNS TO A/E FOR EACH PAINT COLOR FOR REVIEW AND APPROVAL. -t} } SS-I AND 2 BACKSPLASH/ y 6. APPLY PAINT PER MANUFACTURER'S RECOMMENDATIONS. O -- SIDE SPLASH • • 7. NO VOC PAINT SYSTEMS TO BE UTILIZED.TO INCLUDE PRIMERS AS WELL AS FINISH PRODUCTS. o FILASTIC LAMINATE, PL-1 PORTLAND, OREGON 8. EGGSHELL WASHABLE FINISH AT CEILING AND SOFFITS,SATIN WASHABLE FINISH AT WALLS.SEMI-GLOSS FINISH AT ALL TOILET ROOM LO I WALLS AND CEILINGS.FINISH TO HAVE A MASTER PAINTER INDEX OF 3 WITH A GOOD SCRUB RATING AND SHEEN AT 15%-25%AT 60 DEGREES. OCKING LOWER CABINETRY OF 09300 TILE 1 0� 1. INSTALL TILE ACCORDING TO MANUFACTURER'S RECOMMENDED INSTRUCTIONS. ON NON-ADA APPROACH SIDE 2. INSTALLTILE IN ACCORDANCE WITH CURRENT TCA HANDBOOK GUILDLINES AND DETAILS.METHOD F122 FOR FLOORS IN ALL LOCATIONS. ONLY (SEE FLOOR PLAN) MACKENZIE S2019 ER 3. CONTRACTOR TO CONFIRM GROUT SPECIFICATION IS APPROPRIATE FOR EACH AREA OF WORK.REFER TO SCHEDULE OF INTERIOR / WASTE RECEPTACLE UNDER © ALL RIGHTS RESERVED 4. GROUT JOINT REQUESTED IS 1/16".CONFIRM MANUFACTURER RECOMMENDED GROUT JOINT SIZE,NOTIFY PROPERTY MANAGER OF ANY COUNTER W THESE DRAWINGS ARE THE PROPERTY OF g MACKENZIE AND ARE NOT TO RE USED DISCREPANCIES PRIOR TO WORK. OR REPRODUCED IN ANY MANNER, 5. APPLY TILE AND GROUT SEALER AS RECOMMENDED BY MANUFACTURER. 2.-9„ 2.-9„ z WITHOUT PRIOR WRITTEN PERMISSION 6. CONTRACTOR TO COORDINATE PRE-INSTALLATION MEETING ON SITE WITH ARCHITECT AND TILE INSTALLER FOR FINAL LAYOUT REVIEW PRIOR TO INSTALLATION. CUT TILE, PT-1 OPEN TO BELOW, PER CODE. 7. PROVIDE SCHLUTER TRANSITION STRIP WHERE TILE TRANSITIONS TO CARPET.INSTALL TRANSITION STRIP ACCORDING TO 5 -6" FLOORING TO EXTEND > REVISION SCHEDULE MANUFACTURER'S RECOMMENDED INSTRUCTIONS. VANITY AND WALL ELEVATION VERIFY 8. CONTRACTOR TO PROVIDE MOCK-UP FOR REVIEW AND APPROVAL OF CARPET TILE,PORCELAIN TILE AND SCHLUTER TRANSITION PRIOR TO UNDER CABINET w Delta Issued As Issue Date INSTALLATION. Jr,2 MEN'S TOILET 703 39"-41" NEW BACKLIT MIRROR z WALL TILE; REFER S- w ~a 2'-1" TO ELEVATION 3'-0" � " D_ w J 2" SOLID SURFACE o w BACKSPLASH/SIDE SPLASH I Q xID ¢ NEW UNDERMOUNT EXISTING CARPET AS OCCURS M o P R PLA a SINK SEE PLANS FOR REFERENCE I 1'-6" ¢ I1 11 o "� Cv w 't SOLID SURFACE WITH M / EASED EDGE SHEET TITLE: TYPICAL AMBULATORY STALL GRAB BAR SECTION LAVATORY MIRROR II II NO HARDWARE, PROVIDE INTERIOR B q C D II MAGNETIC TOUCH SCHLUTER SCHIENE GRAB BARS NTS LF-i a RELEASE /8' PROFILE DETAILS AND 6" 6' 6" 2" 2x4 AT EACH GROUT SCHEDULES FLAT BAR SUPPORT TILE AS SPECIFIED �f F.B. Y4" x 2" WITH (3) D (L SWITCHES & T usH 1'-8� % U TO 2x4 AT OUNTERRAND EWS THIN SET MORTAR BED CONTROL N ENVIRONMENTAL x x / j o (4) !�"4 MB THRU STUDS ;t CONTROLS T IM N N LOCATE FB SUPPORTS DRAWN BY: KGB L 00 M AT 3'-0" OC MAX a4 EXISTING FLOOR SLAB I / WRAP ALL WASTE AND HOT a °° `..a CHECKED BY: MRT, PDK + WATER SUPPLY LINES °11 as SHEET: E SWITCHES AND OUTLETS F ACCESSORY G ACCESSORY H ACCESSIBLE URINAL ° a ACCESSIBLE RECESSED ACCESSIBLE P-LAM FACES PAPER TOWEL COMBINATION TOILET DISPENSER/WASTE SEAT COVER DISPENSER/ 01 6„ PROVIDE 2x BLOCKING AT A5m2O RECEPTACLE SANITARY NAPKIN NOTE: AT METAL STUDS DISPOSAL/TOILET TISSUE ALL STAINLESS STEEL, BOBRICK OR SIM OPEN ONLY @ ADA DISPENSER (SIM AT MEN'S) ,PORTIONSEE PLAN FOR I ACCESSORIES TO BE SATIN FINISH UNO w w LASETION, PROVIDE AT NON-ADA SINK = JOB NO. 9 TOILET ACCESSORIES AND FIXTURES 11 LAVATORY SECTION co l2 CARPET INSET AT TILE 2190950.06 5.2 MOUNTING HEIGHTS AND DIMENSIONS 1/4"=1'-0" 52 1 1/2"=1'-0" > 52 1'-0"=1'-0" PERMIT SET: 03/26/2020 '219095006'C:\TEMP\HCPUBLISH_14908\D6_A5.20.DWG CAK 03/26/20 13:07 1:96.00 TRACK BLOCKING W/ 1 1/2" FLANGES. SIZE & GAGE TO MATCH METAL STUD CEILING JOISTS. LOCATE IN EVERY 6TH SPACE FOR STUDS ® 16" oc & / ® EACH END OF WALL. / NOTE: CEL.IVG JOIST MAX SPANS 600S137-33 METAL STUD CEILING JOIST ® 16" oc MAX SPAN 17'-6" Architecture • Interiors W/ 200050-54 U—CHANNEL AT MIDSPAN 3625125-18 METAL STUD CEILING JOIST Planning • Engineering ® 16" oc MAX SPAN 7'-9" 3625137-33 METAL STUD CEILING JOIST ® 16" oc MAX SPAN 10'-8" Portland,OR METAL STUD CEILING JOIST 503.224.9560 SEE MAX SPAN NOTE ABOVE / Vancouver,WA 360.695.7879 U—CHANNEL Seattle,WA AS REQ'D 206.749.9993 www.mcknze.com MACKENZIE. #10 SMS AS SHOWN, DESIGN DRIVEN I CLIENT FOCUSED SEE SPECS Client %" GYP BD SEE REFLECTED CEILING PLANS FOR HEIGHTS AFF (,L S H O R E S T E I N 4 CEILING JOIST FRAMING 1 5. METAL STUDS WITH MIDSPAN SUPPORT AND BLOCKING NTS J v Project / ATTACH STUD TRACK 7TH FLOOR / To BRACE ABOVE. TOILET ROOMS ADD TRACK ABOVE LANDLORD SUSPENDED \ / / GYP TO ALIGN WITH IMPROVEMENT GYPSUM CEILING // / LOWER WALL TRACK BELOW GYP 5 LINCOLN 45' 10200 SW GREENBURG RD. .,: . . TIGARD, OREGON METAL STUD BRACING AND TRACK TO FLOOR STRUCTURE ABOVE AT 8'-0" OC �o �l 1*0 FINISHED JOINT—/ W/ (2) #8 SHEET METAL SCREWS AT EACH END. STUD SIZING PER SPAN TABLE. p D. KI ING BRACING TO BE PROVIDED WHERE ��"J SOUND ATTENUATION DISTANCE BETWEEN PERPENDICULAR �T-J AT ALL NEW WALLS, TYP. INTERSECTING WALLS OR HORIZONTAL �i y BRACING BETWEEN WALLS EXCEEDS 8'-0" • • OC, OR PROVIDE CLNG. SUPPORT FOR TOP PORTLAND, OREGON OF WALL EQUAL TO NOTE ABOVE A METAL STUDS SEE WALL HEIGHT 0 GYP BD EA SIDE TABLE, 12/A5.21, FOR GAUGE OF O AND SPACING CONT ACOUSTIC SEALANT EA SIDE AGAINST TRACK NO © MACKENZIE2019 SEALANT AT SIM COND ALL RIGHTS RESERVED 1/2" MAX THESE DRAWINGS ARE THE PROPERTY OF MACKENZIE AND ARE NOT TO BE USED BOTTOM TRACK TO FINISH OR REPRODUCED IN ANY MANNER, CONCRETE SLAB FLOOR W/ POWDER DRIVEN OR PRIOR WRITTEN PERMISSION ANCHORS AT 4'-0" OC I 3 REVISION SCHEDULE s NON—BEARING WALL w z 1 Delta Issued As Issue Date 5. AT FLOOR AND GYPSUM CEILING 3"=1'-0" 3 * 5 LINCOLN STUD SIZE: 2 1/2" * EXCEPT AS NOTED FOR NEW WALL, PROVIDE 3 5/8" STUD LIMITING WALL HEIGHT TABLE WERIOR NON STRUCTURAL WALLS L/240 ® 5psf DESKMTION SPACING MAX. WALL HEK)I-iT 2505125-18 24" 8'-4" 2505725-18 16" 9'-7" SHEET TITLE: 2505125-27 24" 9'-10" INTERIOR 2505125-18 16" 11'-3" DETAILS 3625125-18 24" 13'-5" 362S125-18 16" 14'-4" 3625762-33 16" 16'-5" 362S162-43 16" 18'-0" 600S162-33 16" 24'-6" DRAWN BY: KGB WITH CERAMC TILE FACM WAS/360 ® 5psf CHECKED BY: MRT, PDK LU DESIMATM SPACING MAX. WALL HEPMT m SHEET: 362S125-18 16" 12'-4" H 362S725-33 16" 14'-3" � A5m21w x WALL TABLES ARE BASED ON WALLS SHEATHED BOTH SIDES FULL HEIGHT WITH 1/2" GYPSUM BOARD ATTACHED WITH #6 SCREWS MIN. AT 12"-0" O.C. MAX. 3 JOB No.2190950.06 12 WALL HEIGHT TABLE 5. PERMIT SET: 03/26/2020 '219095006'C:\TEMPWCPUBLISH 14908\O6 A5.21.DWG CAK 03126/20 13:07 1:96.00